476
|
Huggon IC, Ghi T, Cook AC, Zosmer N, Allan LD, Nicolaides KH. Fetal cardiac abnormalities identified prior to 14 weeks' gestation. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2002; 20:22-29. [PMID: 12100413 DOI: 10.1046/j.1469-0705.2002.00733.x] [Citation(s) in RCA: 80] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
OBJECTIVE An increasing number of patients are presenting at early gestational age as being at high risk for congenital heart disease, as a result of ultrasound screening by nuchal translucency. The feasibility and accuracy of fetal echocardiography was assessed in a series of pregnancies studied before 14 weeks' gestation. METHODS Echocardiography was attempted in 478 fetuses of crown-rump length 40.0-85.0 mm (median, 60.3 mm) with increased nuchal translucency, suspected abnormalities on routine scan or a family history of heart defect. The findings were related to results of autopsy, karyotyping, later scans and postnatal follow-up. RESULTS Satisfactory images were obtained transabdominally in 402/478 (84.1%) and transvaginally in a further 13 patients. Cardiac defects were confidently identified in 60 fetuses and abnormalities of uncertain significance (isolated ventricular or great artery disproportion, or tricuspid regurgitation) were observed in a further 49. Defects were suspected in an additional 20 fetuses, and 286 were passed as normal. The karyotype was subsequently demonstrated to be abnormal in 70/286 (24.5%) fetuses with normal echocardiograms, and in 94/129 (72.9%) with abnormal or suspicious cardiac findings. Validation of the scan findings was possible in 241 fetuses. Normal heart structure was confirmed in 204 fetuses, and previously unsuspected cardiac abnormalities revealed in nine. Heart defects were verified in 28 fetuses, but five of these had important additional findings. There were false positive findings in three fetuses. CONCLUSIONS Fetal echocardiography is feasible prior to 14 weeks' gestation. Cardiac defects, when present, may be identified or suspected in the majority of cases. In the risk group studied, heart defects were frequently a manifestation of chromosomal abnormality.
Collapse
|
477
|
Cicero S, Bindra R, Rembouskos G, Tripsanas C, Nicolaides KH. Fetal nasal bone length in chromosomally normal and abnormal fetuses at 11-14 weeks of gestation. J Matern Fetal Neonatal Med 2002; 11:400-2. [PMID: 12389656 DOI: 10.1080/jmf.11.6.400.402] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
OBJECTIVE To determine the value of measuring fetal nasal bone length at 11-14 weeks of gestation in screening for chromosomal defects. METHODS The fetal profile was examined and the nasal bone length was measured in 1092 fetuses immediately before chorionic villous sampling for karyotyping at 11-14 weeks of gestation. RESULTS The median gestation was 12 (11-14) weeks. The fetal profile was successfully examined in all cases. The fetal karyotype was normal in 955 pregnancies and abnormal in 137, including 79 cases of trisomy 21. In the chromosomally normal group, the fetal nasal bone length increased significantly with crown-rump length (CRL) from a mean of 1.3 mm at a CRL of 45 mm to 2.1 mm at a CRL of 84 mm. In 54 of the 79 (68.4%) cases of trisomy 21, the nasal bone was absent. In the 25 cases with present nasal bone, the nasal bone length for the CRL was not significantly different from normal. Similarly, there were no significant differences from normal in the nasal bone length of fetuses with other chromosomal defects. CONCLUSIONS At 11-14 weeks of gestation, the nasal bone length of chromosomally abnormal fetuses is not significantly different from normal.
Collapse
|
478
|
Cicero S, Bindra R, Rembouskos G, Tripsanas C, Nicolaides KH. Fetal nasal bone length in chromosomally normal and abnormal fetuses at 11-14 weeks of gestation. J Matern Fetal Neonatal Med 2002. [DOI: 10.1080/713605572] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
479
|
To MS, Palaniappan V, Skentou C, Gibb D, Nicolaides KH. Elective cerclage vs. ultrasound-indicated cerclage in high-risk pregnancies. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2002; 19:475-477. [PMID: 11982981 DOI: 10.1046/j.1469-0705.2002.00673.x] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
OBJECTIVE To compare pregnancy outcome after elective vs. ultrasound-indicated cervical cerclage in women at high risk of spontaneous mid-trimester loss or early preterm birth. METHODS This was a retrospective study comparing two management strategies in women with singleton pregnancies who had at least one previous spontaneous delivery at 16-33 weeks of gestation. One group was managed by the placement of an elective cerclage at 12-16 weeks and the other group had transvaginal ultrasound examinations of the cervix at 12-15+6, 16-19+6, and 20-23+6 weeks and cervical cerclage was carried out if the cervical length was 25 mm or less. RESULTS A total of 90 patients were examined, including 47 that were managed expectantly and 43 treated by elective cerclage. In the expectantly managed group, 59.6% (28/47) required a cervical cerclage. We excluded from further analysis three patients who were lost to follow-up and three because of fetal death or iatrogenic preterm delivery. Miscarriage or spontaneous delivery before 34 weeks' gestation occurred in 14.6% (6/41) of the elective cerclage group, compared with 20.9% (9/43) in the expectantly managed group (chi2 = 0.219, P = 0.640). CONCLUSION In women at increased risk of spontaneous mid-trimester or early preterm delivery, a policy of sonographic surveillance followed by cervical cerclage in those with a short cervix reduces the need for surgical intervention without significantly increasing adverse pregnancy outcome.
Collapse
|
480
|
Papageorghiou AT, Liao AW, Skentou C, Sebire NJ, Nicolaides KH. Trichorionic triplet pregnancies at 10-14 weeks: outcome after embryo reduction compared to expectant management. J Matern Fetal Neonatal Med 2002; 11:307-12. [PMID: 12389671 DOI: 10.1080/jmf.11.5.307.312] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
OBJECTIVE To compare the outcome of trichorionic triplet pregnancies managed expectantly with those reduced to twins or singletons. METHODS This was a retrospective study of trichorionic triplet pregnancies with three live fetuses at 10-14 (median 12) weeks' gestation referred to our unit for consideration of embryo reduction. Women were counselled as to the available options of either expectant management or embryo reduction. In those choosing reduction, a needle was inserted into the uterus transabdominally and potassium chloride was injected into the fetal heart. Using data derived from this study and from a review of studies reporting on survival and handicap by gestational age in singletons, the effects of embryo reduction on survival and handicap rates were estimated. Main outcome measures were miscarriage before 24 weeks of gestation, preterm delivery before 32 weeks, perinatal death and handicap rates. RESULTS In total, there were 280 trichorionic triplet pregnancies and 125 of these were managed expectantly, 133 were reduced to two fetuses and 22 were reduced to one fetus. The rates of miscarriage were 3.2% for those managed expectantly, 8.3% for those reduced to twins and 13.6% for those reduced to singletons. The rates of early preterm delivery in those pregnancies that did not miscarry were 23.1%, 9.8% and 5.3%, respectively. The percentages for pregnancies with at least one survivor were 95.2%, 91.0% and 81.8%, respectively, and the median gestation at delivery was 34 weeks for the non-reduced, 36 weeks for those reduced to twins and 38 weeks for those reduced to singletons. From the published series on early preterm delivery, it was estimated that survival increases from about 27% at 24 weeks to about 98% at 32 weeks, and handicap decreases from 28% at 24 weeks to less than 5% at 32 weeks. From these estimates and the data on triplet pregnancies, it was calculated that, in triplets reduced to twins, compared to those managed expectantly, the chance of survival is similar (90.3% compared to 93.3%), but the risk of handicap may be lower (0.6% compared to 1.5% per fetus). CONCLUSIONS In trichorionic triplet pregnancies, embryo reduction to twins does not improve the chance of survival but may reduce the rate of handicap. Reduction from triplets to singletons may reduce both the survival rate and the handicap rate among survivors.
Collapse
|
481
|
Papageorghiou AT, Liao AW, Skentou C, Sebire NJ, Nicolaides KH. Trichorionic triplet pregnancies at 10-14 weeks: outcome after embryo reduction compared to expectant management. J Matern Fetal Neonatal Med 2002. [DOI: 10.1080/713605553] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
482
|
Missfelder-Lobos H, Teran E, Lees C, Albaiges G, Nicolaides KH. Platelet changes and subsequent development of pre-eclampsia and fetal growth restriction in women with abnormal uterine artery Doppler screening. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2002; 19:443-448. [PMID: 11982975 DOI: 10.1046/j.1469-0705.2002.00672.x] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
OBJECTIVES To investigate whether, in women with abnormal uterine artery Doppler, platelet volume and function will identify a subgroup of women at increased risk of pre-eclampsia and intrauterine growth restriction and whether in-vitro platelet aggregation precedes the onset of clinical disease. DESIGN Platelet number, volume and aggregation induced by collagen or adenosine 5'-diphosphate were evaluated in 16 non-pregnant controls, 29 pregnant women with normal uterine artery Doppler and 31 pregnant women with abnormal Doppler, hence at risk of pre-eclampsia and intrauterine growth restriction at 23 weeks. Outcome of pregnancy was recorded in each case. RESULTS Twelve women in the group with abnormal uterine artery Doppler subsequently developed pre-eclampsia and/or intrauterine growth restriction. All women with normal uterine artery Doppler had a normal pregnancy outcome. No differences in platelet count or in vitro platelet aggregation induced by collagen were observed between the groups. Mean platelet volume was greater in those with abnormal Doppler who had intrauterine growth restriction or normal pregnancy outcome compared with normal Doppler (10.3 and 10.3 vs. 9.4 fL, P = 0.004 and P = 0.01, respectively). Aggregation induced by adenosine diphosphate was higher in women with abnormal Doppler who developed pre-eclampsia or intrauterine growth restriction compared with those with normal outcomes (66.5 and 66.5 vs. 21%, P = 0.02, P = 0.03, respectively). CONCLUSIONS Women with abnormal uterine artery Doppler at 23 weeks show alterations in mean platelet volume and platelet function that relate to subsequent adverse outcome.
Collapse
|
483
|
Souka AP, Krampl E, Geerts L, Nicolaides KH. Congenital lymphedema presenting with increased nuchal translucency at 13 weeks of gestation. Prenat Diagn 2002; 22:91-2. [PMID: 11857608] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/23/2023]
Abstract
Congenital lymphedema is an autosomal dominant condition characterized by chronic tissue swelling caused by deficient lymphatic drainage due to hypoplastic/aplastic lymphatic vessels and usually affecting the lower limbs. The locus of the gene has been identified in the long arm of chromosome 15. We report one case of congenital lymphedema presenting with increased nuchal translucency at 13 weeks of gestation.
Collapse
|
484
|
Souka AP, Skentou H, Geerts L, Bower S, Nicolaides KH. Congenital nephrotic syndrome presenting with increased nuchal translucency in the first trimester. Prenat Diagn 2002; 22:93-5. [PMID: 11857609 DOI: 10.1002/pd.121] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Congenital nephrotic syndrome of the Finnish type (CNF) and diffuse mesangial sclerosis (DMS) are rare causes of renal failure in infants. We report two cases, one of each condition, presenting with increased nuchal translucency at the 11-14-week scan, and review the literature.
Collapse
|
485
|
Souka AP, Krampl E, Geerts L, Nicolaides KH. Congenital lymphedema presenting with increased nuchal translucency at 13 weeks of gestation. Prenat Diagn 2002. [DOI: 10.1002/pd.104] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
486
|
Pandis GK, Papageorghiou AT, Otigbah CM, Howard RJ, Nicolaides KH. Randomized study of vaginal misoprostol (PGE(1)) and dinoprostone gel (PGE(2)) for induction of labor at term. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2001; 18:629-635. [PMID: 11844203 DOI: 10.1046/j.0960-7692.2001.00595.x] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
OBJECTIVES To investigate the efficacy and safety of misoprostol in the induction of labor at term by comparing this agent with the commonly used dinoprostone gel. PATIENTS AND METHODS A randomized clinical trial of vaginal misoprostol, 50 microg 6-hourly, and dinoprostone gel, 1-2 mg 6-hourly, in 435 women undergoing induction of labor at term. The women, 210 in the misoprostol group and 225 in the dinoprostone group, were compared to determine whether there was a significant difference in achieving vaginal delivery within 24 h, the incidence of hyperstimulation syndrome, Cesarean section rate and adverse neonatal outcome. They were also offered the option of preinduction sonographic cervical assessment. RESULTS Misoprostol, compared to dinoprostone gel, was associated with a significantly shorter median induction-to-delivery interval (14.6 h vs. 19.0 h; P = 0.0014), a higher incidence of vaginal delivery within 24 h of induction (65.7% vs. 54.2%; P = 0.019) and a reduced need for oxytocin augmentation during labor (20.5% vs. 29.8%; P = 0.034). The groups did not differ significantly in the rates of Cesarean section (18.1% vs. 19.1%; P = 0.88) and hyperstimulation syndrome (2.4% vs. 0.9%; P = 0.27). None of the cases of hyperstimulation required treatment with tocolysis. All nine cases of excessive uterine contractility occurred after the first dose of the drug. There were no significant differences in maternal and neonatal morbidity between the two groups. There was a significant association between preinduction cervical length and the induction-to-delivery interval in both those receiving misoprostol and those treated with dinoprostone. CONCLUSIONS The use of misoprostol is associated with a shorter duration of labor and a higher rate of vaginal delivery within 24 h from induction without an increase in maternal and neonatal morbidity. Transvaginal sonographic measurement of cervical length is useful in the prediction of the likelihood of vaginal delivery within 24 h of induction and of the induction-to-delivery interval and may be useful in the stratification of patients participating in randomized studies that examine the effectiveness of inducing agents.
Collapse
|
487
|
Bindra R, Curcio P, Cicero S, Martin A, Nicolaides KH. Uterine artery Doppler at 11-14 weeks of gestation in chromosomally abnormal fetuses. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2001; 18:587-589. [PMID: 11844194 DOI: 10.1046/j.0960-7692.2001.00585.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
OBJECTIVE To determine whether the major chromosomal abnormalities are associated with impaired placentation in the first trimester of pregnancy. METHODS This was a prospective study of 692 singleton pregnancies undergoing fetal karyotyping at 11-14 weeks of gestation. Uterine artery Doppler was carried out and the mean pulsatility index was calculated just before chorionic villus sampling. RESULTS The fetal karyotype was normal in 613 pregnancies and abnormal in 79, including 39 cases of trisomy 21, 11 of trisomy 18, 11 of trisomy 13, eight of Turner syndrome and 10 with other defects. There were no significant differences in the median value of uterine artery mean PI between any of the individual groups. Although in the combined group of trisomy 18, trisomy 13 and Turner syndrome fetuses, the median pulsatility index (1.60) was significantly higher than in the chromosomally normal group (median pulsatility index, 1.51; P = 0.021), in the majority of abnormal fetuses (24 of 30) mean pulsatility index was below the 95th centile of the normal group (mean pulsatility index, 2.34). There was no significant association between uterine artery mean pulsatility index and fetal nuchal translucency thickness or fetal growth deficit. CONCLUSIONS The high intrauterine lethality and fetal growth restriction associated with the major chromosomal abnormalities are unlikely to be the consequence of impaired placentation in the first trimester of pregnancy.
Collapse
|
488
|
Sutcliffe AG, Sebire NJ, Pigott AJ, Taylor B, Edwards PR, Nicolaides KH. Outcome for children born after in utero laser ablation therapy for severe twin-to-twin transfusion syndrome. BJOG 2001; 108:1246-50. [PMID: 11843386 DOI: 10.1111/j.1471-0528.2001.00294.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
OBJECTIVE To examine the postnatal development of a group of children born after in utero laser ablation therapy for severe twin-to-twin transfusion syndrome. DESIGN Retrospective cohort outcome study involving assessment of neurodevelopment and physical well being. SETTING Harris Birthright Centre, King's College Hospital, London. PARTICIPANTS Twins and singleton survivors treated via laser ablation therapy for twin-to-twin transfusion syndrome over a four-year period. METHODS Of 54 families contacted to participate in the study, who had been treated for twin-to-twin transfusion syndrome during a four-year period, 24 families attended for paediatric assessment; 12 pairs of twins and 12 singleton survivors were assessed for perinatal, neurological and neurodevelopmental outcome using the Griffiths scales of mental development. A further 20 families were assessed via a proforma after contact with their general practitioner. A comparison of these groups showed no significant differences in sociodemographic factors or severity of disease between responders (44 families, 81.5%) and non-responders (10 families). RESULTS The group of children assessed by a paediatrician had low birthweight (1619g donor, 1814g recipient, 1877g singleton) and had been born preterm (33 weeks twins, 31.2 weeks singleton) with attendant increased resuscitation, neonatal unit admission (mean 40 days) and instrumental delivery. Mean Griffiths scores were within the normal range of ability (91.2 donor vs 97.7 recipient and 101.6 singletons) with the only significant difference being in the locomotor subscale where donor (82.6) and recipient (85.3) were less than singletons: -99.1 (P < 0.05). There was no cerebral palsy in the singleton survivors, but there were five cases in the twin group. All except one affected child (with quadriplegia) had mean Griffiths scores in the normal range. In the GP proforma group there was one case, in a twin, of cerebral palsy. CONCLUSION The overall cerebral palsy rate was 9%: 0% in the singleton survivors group and 13.3% in the twin survivors group. This pilot data highlights the need for careful long term follow up of children affected by twin-to-twin transfusion syndrome.
Collapse
|
489
|
Al-Mufti R, Hambley H, Farzaneh F, Nicolaides KH. Fetal and embryonic hemoglobins in erythroblasts from fetal blood and fetal cells enriched from maternal blood in fetal anemia. Haematologica 2001; 86:1270-6. [PMID: 11726318] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2023] Open
Abstract
BACKGROUND AND OBJECTIVES To determine whether there is a delay or reversal in switch mechanisms from embryonic (e and z) to fetal (g) hemoglobins accompanying the erythroblastosis of anemic fetuses and whether an increased erythroblast count in fetal blood is associated with an increase in feto-maternal cell trafficking. DESIGN AND METHODS Fetal and maternal blood samples were obtained from 10 cases with rhesus isoimmunization and 2 cases with maternal Parvo-B19 virus at 19-33 weeks' gestation. Blood samples were also taken as controls from 61 fetuses and 86 mothers. Fetal erythroblasts were isolated by triple density gradient centrifugation and magnetic cell sorting with CD71 antibody. Fluorescent antibodies were used to immuno-stain for zeta (z), epsilon (e) and gamma (g) hemoglobin chains. In the maternal samples, fluorescence in situ hybridization (FISH) for X and Y chromosomes was also carried out to confirm the presence and proportion of the enriched fetal cells from maternal blood. RESULTS In both fetal and maternal blood the percentage of erythroblasts positive for g-globin chain was significantly higher in the anemic fetuses compared to the controls (fetal blood, p<0.001, R=0.91; maternal blood, p<0.001, R=0.56), but there was no significant difference in expression of the e and z-chains. The percentage of cells with Y-signals was also higher in the maternal samples of anemic fetuses compared to normal controls (p<0.001, R=0.56). INTERPRETATION AND CONCLUSIONS These findings suggest that the erythroblastosis of anemic fetuses is not accompanied by a delay or a reversal in switch from embryonic to fetal hemoglobin chains. Severe fetal anemia is associated with an increase in feto-maternal cell trafficking.
Collapse
|
490
|
Martin AM, Bindra R, Curcio P, Cicero S, Nicolaides KH. Screening for pre-eclampsia and fetal growth restriction by uterine artery Doppler at 11-14 weeks of gestation. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2001; 18:583-586. [PMID: 11844193 DOI: 10.1046/j.0960-7692.2001.00594.x] [Citation(s) in RCA: 242] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
OBJECTIVE To examine the value of uterine artery Doppler at 11-14 weeks of gestation in the identification of women at risk of developing pre-eclampsia and fetal growth restriction. METHODS Uterine artery Doppler was carried out at 11-14 weeks in 3324 consecutive singleton pregnancies attending for routine care in three London hospitals. The right and left uterine arteries were identified using color flow mapping and velocity waveforms were obtained using pulsed Doppler. The mean pulsatility index of the two arteries was determined and the predictive value of a mean pulsatility index > the 95th centile in the prediction of pre-eclampsia and/or fetal growth restriction was calculated. RESULTS Satisfactory flow velocity waveforms were obtained from both uterine arteries in 3195 (96.1%) of the 3324 pregnancies examined and complete outcome information was obtained for 3045 (95.3%) of these women. The 95th centile of the uterine artery mean pulsatility index was 2.35 and did not change significantly with gestational age. The pregnancy was complicated by pre-eclampsia in 63 (2.1%) cases and by fetal growth restriction in 290 (9.5%) cases. The sensitivity of a mean pulsatility index > 2.35 for pre-eclampsia (with or without fetal growth restriction) was 27.0% but for fetal growth restriction alone it was 11.7%. The respective sensitivities for these complications requiring delivery before 32 weeks of gestation were 60.0% and 27.8%, respectively. CONCLUSION Uterine artery Doppler at 11-14 weeks of gestation identifies a high proportion of women who develop severe pre-eclampsia and/or fetal growth restriction.
Collapse
|
491
|
Pandis GK, Papageorghiou AT, Ramanathan VG, Thompson MO, Nicolaides KH. Preinduction sonographic measurement of cervical length in the prediction of successful induction of labor. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2001; 18:623-628. [PMID: 11844202 DOI: 10.1046/j.0960-7692.2001.00580.x] [Citation(s) in RCA: 89] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
BACKGROUND Induction of labor is carried out in approximately 20% of pregnancies. However, approximately 20% of women having induction of labor end up having a Cesarean delivery. The traditional method of predicting whether an induced labor will result in successful vaginal delivery is based on the preinduction "favorability" of the cervix as assessed by the Bishop score. However, this assessment is subjective and several studies have shown a poor predictive value for the outcome of induction. OBJECTIVES To examine the relationship between preinduction sonographically measured cervical length and the Bishop score and to compare the two measurements in the prediction of successful vaginal delivery within 24 h of induction. METHODS In this multicenter study, preinduction cervical assessment was undertaken in 240 women with singleton pregnancies at 37-42 weeks of gestation. The Bishop score was assessed by digital examination and the cervical length was measured by transvaginal sonography. RESULTS Multiple regression analysis demonstrated that cervical length, Bishop score and parity provided independent contribution in the prediction of the likelihood of delivering vaginally within 24 h. Further examination of the different components of the Bishop score showed that only cervical length provided a significant contribution in the prediction of the likelihood of vaginal delivery within 24 h. In the receiver operating characteristic curves, the best cut-off point for the prediction of successful induction was 28 mm for cervical length and 3 for the Bishop score. However, cervical length appears to be a better predictor than the Bishop score, with a sensitivity of 0.87 and a specificity of 0.71 compared to 0.58 and 0.77, respectively. Similarly, the Kaplan-Meier survival curves indicate that better discriminatory results in the prediction of vaginal delivery within 24 h are achieved using cervical length rather than the Bishop score. CONCLUSION Transvaginal sonographic measurement of cervical length provides a useful prediction of the likelihood of vaginal delivery within 24 h of induction.
Collapse
|
492
|
Savvidou MD, Vallance PJ, Nicolaides KH, Hingorani AD. Endothelial nitric oxide synthase gene polymorphism and maternal vascular adaptation to pregnancy. Hypertension 2001; 38:1289-93. [PMID: 11751705 DOI: 10.1161/hy1201.097305] [Citation(s) in RCA: 78] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
A common polymorphism of the endothelial NO synthase gene that predicts a Glu298Asp amino acid substitution in the mature protein has been associated with cardiovascular disorders in which NO bioactivity is impaired. However, the influence of this polymorphism on endothelial function is unknown. Healthy pregnancy is associated with enhanced endothelium-dependent, flow-mediated dilation (FMD) of the brachial artery, a response mediated by NO. In this study, we investigated the effect of the endothelial NO synthase Glu298Asp polymorphism on endothelium-dependent vasodilation in early pregnancy, making the hypothesis that any genotype-dependent differences in NO generation would be more marked during pregnancy, when the production of NO is upregulated. FMD of the brachial artery was recorded during the first trimester in 139 healthy women with normal singleton pregnancies genotyped for the Glu298Asp variant of endothelial NO synthase. Maternal FMD exhibited a codominant inverse relation with the number of Asp298 alleles (r=-0.21, P=0.01). Among homozygotes for endothelial NO synthase Asp298, FMD (7.99+/-1.46%) was significantly lower than that observed among individuals homozygous for endothelial NO synthase Glu298 (10.12+/-3.44) (P=0.002). In a backward stepwise multiple regression analysis, vessel size (P<0.0001) and Glu298Asp polymorphism (P=0.01) were significantly and independently correlated with FMD. Our findings indicate that the endothelial NO synthase Glu298Asp polymorphism is associated with differences in endothelium-dependent dilation at 12-week gestation and are the first to implicate genetic factors in the normal vascular adaptation to pregnancy. They also provide a potential mechanism linking the endothelial NO synthase polymorphism with the development of cardiovascular disorders and have implications for understanding the genetic basis of preeclampsia.
Collapse
|
493
|
Ghi T, Huggon IC, Zosmer N, Nicolaides KH. Incidence of major structural cardiac defects associated with increased nuchal translucency but normal karyotype. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2001; 18:610-614. [PMID: 11844199 DOI: 10.1046/j.0960-7692.2001.00584.x] [Citation(s) in RCA: 76] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
OBJECTIVE To examine the association between increased nuchal translucency thickness and major cardiac defects in chromosomally normal fetuses. SETTING Tertiary referral unit for fetal medicine and fetal cardiology. METHODS During a 4-year period (January 1997 to January 2001), detailed echocardiography was performed in 1319 chromosomally normal fetuses with increased nuchal translucency thickness at 10-14 weeks of gestation. The incidence of major cardiac defects was examined in relation to the fetal NT at the 10-14-week scan. RESULTS Major cardiac defects were diagnosed in 60 (4.5%) of the 1319 fetuses. In fetuses with a nuchal translucency thickness in the range of 2.5-3.4 mm, the incidence of major cardiac defects was 2.5% (18/722; 95% confidence interval, 1.5-3.9) and in those with a nuchal translucency thickness > or =3.5 mm, it was 7% (42/597; 95% confidence interval, 5.1-9.4). CONCLUSION Specialist echocardiography is indicated in all fetuses with increased nuchal translucency thickness because, in such fetuses, the incidence of major cardiac defects is substantially higher than in pregnancies with maternal diabetes, family history and exposure to drugs, where fetal echocardiography is widely considered to be necessary.
Collapse
|
494
|
Papageorghiou AT, Yu CK, Bindra R, Pandis G, Nicolaides KH. Multicenter screening for pre-eclampsia and fetal growth restriction by transvaginal uterine artery Doppler at 23 weeks of gestation. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2001; 18:441-449. [PMID: 11844162 DOI: 10.1046/j.0960-7692.2001.00572.x] [Citation(s) in RCA: 337] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
OBJECTIVE To determine the value of transvaginal color Doppler assessment of the uterine arteries at 23 weeks of gestation in predicting the subsequent development of pre-eclampsia and fetal growth restriction. PATIENTS AND METHODS Women with singleton pregnancies attending for routine ultrasound examination at 23 weeks in any one of seven hospitals underwent Doppler assessment of the uterine arteries. The presence of an early diastolic notch in the waveform was noted, and the mean pulsatility index of the two arteries was calculated. Screening characteristics in the prediction of pre-eclampsia and the delivery of a low birth-weight infant were calculated. RESULTS Doppler examination of the uterine arteries was attempted in 8335 consecutive singleton pregnancies, satisfactory waveforms were obtained from both vessels in 8202 (98.4%) cases and complete outcome data were available in 7851 (95.7%) of these. The mean gestational age was 23 (range, 22-24) weeks. The mean uterine artery pulsatility index did not change significantly with gestation (r = -0.0078; P = 0.483); the median value was 1.04 and the 95th centile was 1.63. In 9.3% of cases early diastolic notches in the waveform from both uterine arteries were present and in an additional 11.1% of cases there were notches unilaterally. Pre-eclampsia with fetal growth restriction occurred in 42 (0.5%) cases, pre-eclampsia without fetal growth restriction in 71 (0.9%) and fetal growth restriction without pre-eclampsia in 698 (8.9%). The sensitivity of increased pulsatility index above the 95th centile (1.63) for pre-eclampsia with fetal growth restriction was 69%, for pre-eclampsia without fetal growth restriction was 24%, for fetal growth restriction without pre-eclampsia was 13%, for pre-eclampsia irrespective of fetal growth restriction was 41% and for fetal growth restriction irrespective of pre-eclampsia was 16%. The sensitivity of fetal growth restriction defined by the 5th rather than the 10th centile was higher (19% vs. 16%). The sensitivity for both pre-eclampsia and fetal growth restriction was inversely related to the gestational age at delivery; when delivery occurred before 32 weeks, the sensitivity for all cases of pre-eclampsia with fetal growth restriction, pre-eclampsia without fetal growth restriction and fetal growth restriction without pre-eclampsia increased to 93%, 80% and 56%, respectively. The sensitivity of bilateral notches in predicting pre-eclampsia and/or fetal growth restriction was similar to that of increased pulsatility index but the screen-positive rate with notches (9.3%) was much higher than that with increased pulsatility index (5.1%). CONCLUSIONS A one-stage color Doppler screening program at 23 weeks identifies most women who subsequently develop severe pre-eclampsia and/or fetal growth restriction.
Collapse
|
495
|
Rodriguez-Niedenführ M, Papoutsi M, Christ B, Nicolaides KH, von Kaisenberg CS, Tomarev SI, Wilting J. Prox1 is a marker of ectodermal placodes, endodermal compartments, lymphatic endothelium and lymphangioblasts. ANATOMY AND EMBRYOLOGY 2001; 204:399-406. [PMID: 11789987 DOI: 10.1007/s00429-001-0214-9] [Citation(s) in RCA: 80] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
The lymphatic endothelium has mostly been thought to be derived by sprouting from specialized veins. Recently it has been shown that mice deficient for the homeobox transcription factor Prox1 are practically devoid of lymphatics. We have studied the expression of Prox1 mRNA and protein in chick embryos and human fetuses. In the chick, Prox1 is expressed in specific compartments of all germ layers. In the ectoderm, it is found in the neural tube, trigeminal, spinal and sympathetic ganglia and the retina, and also in placodal structures such as the lens, olfactory, otic, facial, glossopharyngeal and vagal placodes, and the apical ectodermal ridge. In the endoderm, Prox1 is a marker of hepatocytes, bile duct and pancreatic epithelium. In the mesoderm, weak expression is observed in cardiomyocytes, and strong expression in lymphatic endothelium. Identical expression domains are found in 19-week-old human fetuses. In day 6.5 chick embryos, there are several sites of contact of lymphatics with the jugular vein, which has a mixed endothelium of Prox1-positive and -negative cells. The only non-lymphatic endothelial cells expressing Prox1 are found on the concave side of the cardiac valves. To further analyse development of lymphatics, we studied early chick embryos and observed scattered Prox1-positive cells in the dermatome, giving rise to Prox1-positive lymphatic networks during subsequent development. Furthermore, the anlagen of the posterior lymph sacs and the paired thoracic duct can already be observed in day-4 chick embryos. Our studies show that lymphatics develop much earlier than previously described, and they mostly do not seem to be derived by sprouting from veins. In contrast, lymphangioblasts are present in the deep and superficial compartments of the early mesoderm, independently giving rise to the deep and superficial lymphatics.
Collapse
|
496
|
Papageorghiou AT, To MS, Yu CK, Nicolaides KH. Repeatability of measurement of uterine artery pulsatility index using transvaginal color Doppler. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2001; 18:456-459. [PMID: 11844164 DOI: 10.1046/j.0960-7692.2001.00578.x] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
OBJECTIVE To assess the repeatability of measuring the pulsatility index of the uterine arteries using transvaginal color Doppler at 23 weeks of gestation. PATIENTS AND METHODS The pulsatility index was measured in 100 women with singleton pregnancies attending for routine transvaginal Doppler examination of the uterine arteries at 23 weeks. To assess the repeatability of different components of variability, six measurements of the uterine artery pulsatility index were made on one of the uterine arteries in each patient. RESULTS Six measurements of the pulsatility index were successfully measured in all 100 patients, resulting in a total of 600 measurements. The repeatability was unrelated to the pulsatility index. On 95% of occasions the intraobserver, interobserver and waveform tracing repeatability was less than 0.24, 0.27 and 0.14, respectively. CONCLUSIONS Measurement of the pulsatility index using transvaginal color Doppler is highly reproducible when the examination is carried out by well-trained operators.
Collapse
|
497
|
Kametas NA, McAuliffe F, Cook B, Nicolaides KH, Chambers J. Maternal left ventricular transverse and long-axis systolic function during pregnancy. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2001; 18:467-474. [PMID: 11844166 DOI: 10.1046/j.0960-7692.2001.00574.x] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
OBJECTIVES Circumferential fiber shortening has been the dominant basis for conventional analysis by echocardiography of left ventricular systolic function during pregnancy. Results in the literature have been conflicting due mainly to the fact that geometric assumptions for the calculation of these indices are made that may not be valid due to changes in left ventricular shape during pregnancy. Left ventricular long-axis displacement is expected to be a useful index of systolic function, independent of the changes in left ventricular geometry. The aim of this study was to compare circumferential to long-axis shortening during left ventricular contraction in pregnant women. METHODS This was a cross-sectional study of 125 pregnant women at 9-42 weeks of gestation and 19 non-pregnant female controls. Two-dimensional and M-mode echocardiography of the left ventricle was performed including measurement of left ventricular long-axis displacement and activation time on the lateral, septal, anterior and inferior sides of the mitral annulus. Activation time was assessed as the time from the start of the Q-wave of the electrocardiogram to the onset of left ventricular long-axis shortening. RESULTS Mean arterial pressure and activation time decreased during pregnancy, reaching a nadir at about 19 weeks' gestational age of 4% and 13%, respectively, below non-pregnant values; they subsequently increased towards term. Left ventricular long-axis displacement mirrored the changes in mean arterial pressure and activation time and increased with gestational age at all four sites of the atrioventricular plane reaching a peak at about 23 weeks (+ 12% compared to non-pregnant levels). The ejection fraction and fractional shortening remained stable until 30 and 32 weeks, respectively, and then decreased towards term. CONCLUSION Changes in left ventricular long-axis performance during pregnancy occur earlier than do measures of transverse function.
Collapse
|
498
|
Kametas NA, McAuliffe F, Hancock J, Chambers J, Nicolaides KH. Maternal left ventricular mass and diastolic function during pregnancy. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2001; 18:460-466. [PMID: 11844165 DOI: 10.1046/j.0960-7692.2001.00573.x] [Citation(s) in RCA: 69] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
OBJECTIVE To evaluate changes in left ventricular mass and diastolic function during normal pregnancy. METHODS This was a cross-sectional study of 125 pregnant women at 9-42 weeks of gestation and 19 non-pregnant female controls. Two-dimensional and M-mode echocardiography of the maternal left ventricle and left atrium was performed. RESULTS During pregnancy left ventricular mass increased by 52%. There was an increase in left ventricular end-diastolic and end-systolic diameters (12% and 20%, respectively), left ventricular posterior wall diameter during diastole and systole (22% and 13%, respectively) and left intraventricular septum during diastole and systole (15% and 19%, respectively). Mitral valve A-wave maximum velocity increased during pregnancy by 19%, while mitral valve E-wave maximum velocity and the ratio of E-wave/A-wave velocities increased early in pregnancy by about 14% and 6%, respectively, with a subsequent decline to 4% and 10%, respectively, below non-pregnant levels. CONCLUSION Left ventricular mass increases during pregnancy, while left ventricular diastolic function, as demonstrated by the changes in mitral valve flow velocities, increases in the first two trimesters but declines in the third trimester.
Collapse
|
499
|
Ofori-Acquah SF, Green BN, Davies SC, Nicolaides KH, Serjeant GR, Layton DM. Mass spectral analysis of asymmetric hemoglobin hybrids: demonstration of Hb FS (alpha2gammabetaS) in sickle cell disease. Anal Biochem 2001; 298:76-82. [PMID: 11673898 DOI: 10.1006/abio.2001.5358] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Formation of the asymmetric hemoglobin hybrid FS (alpha2gammabetaS) inhibits hemoglobin S (Hb S) polymerization in vitro and underlies the protective effect of fetal hemoglobin (Hb F) in homozygous sickle cell disease. Conventional methods for separating Hb reveal only symmetric Hb tetramers because of the rapid dissociation of tetramers to dimers relative to the separation time for electrophoresis and chromatography. To gain insight into the quantitative distribution of asymmetric Hb FS and other tetrameric species in sickle cell disease, the noncovalent association of Hb subunits in hemolysates was studied by a novel application of electrospray ionization mass spectrometry (ESI-MS). Mass spectra of both patient and fetal blood revealed predominance of tetrameric species with dimer and monomer subunits in lower abundance. ESI-MS analysis revealed the hybrid Hb AF (alpha2gammabetaA) in hemolysates shown by conventional high-performance liquid chromatography to contain only the symmetric species Hb A (alpha2betaA2) and Hb F (alpha2gamma2). A unique tetramer of average mass 64,558 Da was identified in hemolysates from patients with sickle cell disease in accordance with the calculated mass of the asymmetric Hb hybrid FS. Hybrid Hb species were stable under the ESI-MS conditions employed allowing concurrent determination of the proportions of Hb FS and the symmetrical Hb S (alpha2betaS2). The ratios of Hb FS to Hb S correlated closely (r2 = 0.96) with those predicted under physiological conditions.
Collapse
|
500
|
Paul C, Krampl E, Skentou C, Jurkovic D, Nicolaides KH. Measurement of fetal nuchal translucency thickness by three-dimensional ultrasound. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2001; 18:481-484. [PMID: 11844168 DOI: 10.1046/j.0960-7692.2001.00547.x] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
OBJECTIVE To investigate the feasibility and repeatability of nuchal translucency thickness measurement using three-dimensional ultrasound. METHODS Forty consecutive women with uncomplicated singleton pregnancies attending for Down syndrome screening at 11-14 weeks' gestation were included in this prospective crossover trial. Nuchal translucency thickness was measured using both two-dimensional and three-dimensional ultrasound. In each case two three-dimensional volumes were recorded and then examined by using the technique of planar reformatted sections. The initial plane of the first volume always contained a clear image of the nuchal region ('sagittal volume'), whilst the initial plane of the second volume was selected randomly regardless of fetal position ('random volume'). The repeatability of nuchal translucency measurement was examined by constructing a scatter diagram of the difference between the measurements plotted against the mean of two readings. RESULTS Nuchal translucency measurements could be repeated in 38/40 (95%) sagittal volumes and 24/40 (60%) random volumes. The mean difference between two-dimensional measurements and those obtained by reslicing of sagittal three-dimensional volumes was -0.097 mm (95% limits of agreement from -0.481 to 0.675) and 0.225 mm (95% limits of agreement from -0.369 to 0.819) when random volumes were examined. CONCLUSIONS Reslicing of stored three-dimensional volumes can be used to replicate nuchal translucency measurements only when nuchal skin can also be clearly seen on two-dimensional ultrasound.
Collapse
|