51
|
van den Berg NWE, Neefs J, Kawasaki M, Nariswari FA, Wesselink R, Fabrizi B, Jongejan A, Klaver MN, Havenaar H, Hulsman EL, Wintgens LIS, Baalman SWE, Meulendijks ER, van Boven WJ, de Jong JSSG, van Putte BP, Driessen AHG, Boersma LVA, de Groot JR. Extracellular matrix remodeling precedes atrial fibrillation: Results of the PREDICT-AF trial. Heart Rhythm 2021; 18:2115-2125. [PMID: 34332113 DOI: 10.1016/j.hrthm.2021.07.059] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 07/08/2021] [Accepted: 07/23/2021] [Indexed: 01/18/2023]
Abstract
BACKGROUND To which extent atrial remodeling occurs before atrial fibrillation (AF) is unknown. OBJECTIVE The PREventive left atrial appenDage resection for the predICtion of fuTure Atrial Fibrillation (PREDICT-AF) study investigated such subclinical remodeling, which may be used for risk stratification and AF prevention. METHODS Patients (N = 150) without a history of AF with a CHA2DS2-VASc score of ≥2 at an increased risk of developing AF were included. The left atrial appendage was excised and blood samples were collected during elective cardiothoracic surgery for biomarker discovery. Participants were followed for 2 years with Holter monitoring to determine any atrial tachyarrhythmia after a 50-day blanking period. RESULTS Eighteen patients (12%) developed incident AF, which was associated with increased tissue gene expression of collagen I (COL1A1), collagen III (COL3A1), and collagen VIII (COL8A2), tenascin-C (TNC), thrombospondin-2 (THBS2), and biglycan (BGN). Furthermore, the fibroblast activating endothelin-1 (EDN1) and sodium voltage-gated channel β subunit 2 (SCN2B) were associated with incident AF whereas the Kir2.1 channel (KCNJ2) tended to downregulate. The plasma levels of COL8A2 and TNC correlated with tissue expression and predicted incident AF. A gene panel including tissue KCNJ2, COL1A1, COL8A2, and EDN1 outperformed clinical prediction models in discriminating incident AF. CONCLUSION The PREDICT-AF study demonstrates that atrial remodeling occurs long before incident AF and implies future potential for early patient identification and therapies to prevent AF (ClinicalTrials.gov identifier NCT03130985).
Collapse
|
52
|
De With RR, Erküner Ö, Rienstra M, Nguyen BO, Körver FWJ, Linz D, Cate Ten H, Spronk H, Kroon AA, Maass AH, Blaauw Y, Tieleman RG, Hemels MEW, de Groot JR, Elvan A, de Melis M, Scheerder COS, Al-Jazairi MIH, Schotten U, Luermans JGLM, Crijns HJGM, Van Gelder IC. Temporal patterns and short-term progression of paroxysmal atrial fibrillation: data from RACE V. Europace 2021; 22:1162-1172. [PMID: 32642768 PMCID: PMC7400474 DOI: 10.1093/europace/euaa123] [Citation(s) in RCA: 36] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
Aims Atrial fibrillation (AF) often starts as a paroxysmal self-terminating arrhythmia. Limited information is available on AF patterns and episode duration of paroxysmal AF. In paroxysmal AF patients, we longitudinally studied the temporal AF patterns, the association with clinical characteristics, and prevalence of AF progression. Methods and results In this interim analysis of the Reappraisal of AF: Interaction Between HyperCoagulability, Electrical Remodelling, and Vascular Destabilisation in the Progression of AF (RACE V) registry, 202 patients with paroxysmal AF were followed with continuous rhythm monitoring (implantable loop recorder or pacemaker) for 6 months. Mean age was 64 ± 9 years, 42% were women. Atrial fibrillation history was 2.1 (0.5–4.4) years, CHA2DS2-VASc 1.9 ± 1.3, 101 (50%) had hypertension, 69 (34%) heart failure. One-third had no AF during follow-up. Patients with long episodes (>12 hours) were often men with more comorbidities (heart failure, coronary artery disease, higher left ventricular mass). Patients with higher AF burden (>2.5%) were older with more comorbidities (worse renal function, higher calcium score, thicker intima media thickness). In 179 (89%) patients, 1-year rhythm follow-up was available. On a quarterly basis, average daily AF burden increased from 3.2% to 3.8%, 5.2%, and 6.1%. Compared to the first 6 months, 111 (62%) patients remained stable during the second 6 months, 39 (22%) showed progression to longer AF episodes, 8 (3%) developed persistent AF, and 29 (16%) patients showed AF regression. Conclusions In paroxysmal AF, temporal patterns differ suggesting that paroxysmal AF is not one entity. Atrial fibrillation burden is low and determined by number of comorbidities. Atrial fibrillation progression occurred in a substantial number. Trial registration number Clinicaltrials.gov identifier NCT02726698.
Collapse
|
53
|
de Vries TAC, Hemels MEW, Cools F, Crijns HJGM, Yperzeele L, Vanacker P, Blankoff I, Lancellotti P, Mairesse GH, de Veer A, Casado Arroyo R, Catez E, de Pauw M, Vanassche T, de Asmundis C, Kirchhof P, De Caterina R, de Groot JR. Characteristics of patients with atrial fibrillation prescribed edoxaban in Belgium and The Netherlands: insights from the ETNA-AF-Europe study. Acta Cardiol 2021; 76:431-439. [PMID: 33406996 DOI: 10.1080/00015385.2020.1746095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2020] [Revised: 03/17/2020] [Accepted: 03/18/2020] [Indexed: 10/22/2022]
Abstract
BACKGROUND Studies on the use of non-vitamin K antagonist oral anticoagulants in unselected patients with atrial fibrillation (AF) show that clinical characteristics and dosing practices differ per region, but lack data on edoxaban. METHODS With data from Edoxaban Treatment in routiNe clinical prActice for patients with AF in Europe (ETNA-AF-Europe), a large prospective observational study, we compared clinical characteristics (including the dose reduction criteria for edoxaban: creatinine clearance 15-50 mL/min, weight ≤60 kg, and/or use of strong p-glycoprotein inhibitors) of patients from Belgium and the Netherlands (BeNe) with those from other European countries (OEC). RESULTS Of all 13,639 patients in ETNA-AF-Europe, 2579 were from BeNe. BeNe patients were younger than OEC patients (mean age: 72.3 vs 73.9 years), and had lower CHA2DS2-VASc (mean: 2.8 vs 3.2) and HAS-BLED scores (mean: 2.4 vs 2.6). Patients from BeNe less often had hypertension (61.6% vs 80.4%), and/or diabetes mellitus (17.3% vs 23.1%) than patients from OEC. Moreover, relatively fewer patients in BeNe were prescribed the reduced dose of 30 mg edoxaban (14.8%) than in OEC (25.4%). Overall, edoxaban was dosed according to label in 83.1% of patients. Yet, 30 mg edoxaban was prescribed in the absence of any dose reduction criteria in 36.9% of 30 mg users (5.5% of all patients) in BeNe compared with 35.5% (9.0% of all patients) in OEC. CONCLUSION There were several notable differences between BeNe and OEC regarding clinical characteristics and dosing practices in patients prescribed edoxaban, which are relevant for the local implementation of dose evaluation and optimisation. TRIAL REGISTRATION NCT02944019; Date of registration: October 24, 2016.
Collapse
|
54
|
Mulder BJ, de Groot JR. ICD implantation as primary prevention in systemic RV? A cautious attitude is justified. INTERNATIONAL JOURNAL OF CARDIOLOGY CONGENITAL HEART DISEASE 2021. [DOI: 10.1016/j.ijcchd.2021.100130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022] Open
|
55
|
de Groot JR, Ruff CT, Murphy SA, Hamershock RA, Vehmeijer JT, Oude Ophuis AJ, Grip L, Lanz H, Mercuri MF, Antman EM, Giugliano RP. Edoxaban versus warfarin in patients with atrial fibrillation in relation to the risk of stroke: A secondary analysis of the ENGAGE AF-TIMI 48 study. Am Heart J 2021; 235:132-139. [PMID: 33493453 DOI: 10.1016/j.ahj.2021.01.013] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Accepted: 01/19/2021] [Indexed: 01/21/2023]
Abstract
INTRODUCTION The efficacy and safety of the oral factor Xa inhibitor edoxaban compared to warfarin stratified by CHA2DS2VASc scores have not been described. METHODS The ENGAGE AF-TIMI 48 trial randomized patients with atrial fibrillation to once-daily edoxaban or warfarin. We classified patients based on CHA2DS2VASc score and compared pharmacokinetics (edoxaban concentration), pharmacodynamics (anti-factor Xa [FXa] with edoxaban, time-in-therapeutic range for warfarin), efficacy (stroke or systemic embolism [SSE]), safety (major bleeding [MB], intracranial hemorrhage), and cardiovascular mortality, for the approved edoxaban regimen vs warfarin. RESULTS The distribution CHA2DS2VASc score were:≤3, N = 4159 (29.6%); 4, N = 4066 (28.9%); 5, N = 3165 (22.5%); and ≥6, N = 2681 (19.1%). Increasing rates of SSE (1.05 to 2.99%/year) and MB (2.27 to 4.66%/year) were observed in the warfarin arm as the CHA2DS2VASc score increased. The hazard ratios per unit increase of CHA2DS2VASc score were 1.29 (1.21-1.38) and 1.26 (1.17-1.36) for SSE, and 1.20 (1.13-1.27) and 1.19 (1.12-1.27) for MB, with warfarin and edoxaban, respectively. Time-in-therapeutic range in warfarin-treated patients was similar and high (median 68%-69%) across CHA2DS2VASc scores, whereas edoxaban trough concentration, exogenous anti-FXa activity and %inhibition of endogenous FXa were higher at increasing CHA2DS2VASc scores. Edoxaban reduced SSE, MB, intracranial hemorrhage, and cardiovascular mortality vs warfarin to a similar degree across the range of CHA2DS2VASc scores (P-int = 0.90, 0.96, 0.21, and 0.37, respectively). Because of higher event rates the number of events prevented with edoxaban tended to be greater in patients with higher CHA2DS2VASc scores. CONCLUSION The benefit and safety of edoxaban versus warfarin is maintained across CHA2DS2VASc scores. While the relative risk reductions remain similar, edoxaban provides incrementally larger absolute reductions in outcomes over warfarin in patients with higher CHA2DS2VASc scores.
Collapse
|
56
|
Verkerk AO, Marchal GA, Zegers JG, Kawasaki M, Driessen AHG, Remme CA, de Groot JR, Wilders R. Patch-Clamp Recordings of Action Potentials From Human Atrial Myocytes: Optimization Through Dynamic Clamp. Front Pharmacol 2021; 12:649414. [PMID: 33912059 PMCID: PMC8072333 DOI: 10.3389/fphar.2021.649414] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2021] [Accepted: 02/18/2021] [Indexed: 11/29/2022] Open
Abstract
Introduction: Atrial fibrillation (AF) is the most common cardiac arrhythmia. Consequently, novel therapies are being developed. Ultimately, the impact of compounds on the action potential (AP) needs to be tested in freshly isolated human atrial myocytes. However, the frequent depolarized state of these cells upon isolation seriously hampers reliable AP recordings. Purpose: We assessed whether AP recordings from single human atrial myocytes could be improved by providing these cells with a proper inward rectifier K+ current (IK1), and consequently with a regular, non-depolarized resting membrane potential (RMP), through “dynamic clamp”. Methods: Single myocytes were enzymatically isolated from left atrial appendage tissue obtained from patients with paroxysmal AF undergoing minimally invasive surgical ablation. APs were elicited at 1 Hz and measured using perforated patch-clamp methodology, injecting a synthetic IK1 to generate a regular RMP. The injected IK1 had strong or moderate rectification. For comparison, a regular RMP was forced through injection of a constant outward current. A wide variety of ion channel blockers was tested to assess their modulatory effects on AP characteristics. Results: Without any current injection, RMPs ranged from −9.6 to −86.2 mV in 58 cells. In depolarized cells (RMP positive to −60 mV), RMP could be set at −80 mV using IK1 or constant current injection and APs could be evoked upon stimulation. AP duration differed significantly between current injection methods (p < 0.05) and was shortest with constant current injection and longest with injection of IK1 with strong rectification. With moderate rectification, AP duration at 90% repolarization (APD90) was similar to myocytes with regular non-depolarized RMP, suggesting that a synthetic IK1 with moderate rectification is the most appropriate for human atrial myocytes. Importantly, APs evoked using each injection method were still sensitive to all drugs tested (lidocaine, nifedipine, E-4031, low dose 4-aminopyridine, barium, and apamin), suggesting that the major ionic currents of the atrial cells remained functional. However, certain drug effects were quantitatively dependent on the current injection approach used. Conclusion: Injection of a synthetic IK1 with moderate rectification facilitates detailed AP measurements in human atrial myocytes. Therefore, dynamic clamp represents a promising tool for testing novel antiarrhythmic drugs.
Collapse
|
57
|
Mol D, de Jong JSSG, de Groot JR. On the Dutch Registry of catheter ablation of atrial fibrillation: Authors' reply. Europace 2021; 23:1331-1332. [PMID: 33779709 DOI: 10.1093/europace/euab068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Accepted: 03/03/2021] [Indexed: 11/13/2022] Open
|
58
|
Vehmeijer JT, Koyak Z, Leerink JM, Zwinderman AH, Harris L, Peinado R, Oechslin EN, Robbers-Visser D, Groenink M, Boekholdt SM, de Winter RJ, Oliver JM, Bouma BJ, Budts W, Van Gelder IC, Mulder BJM, de Groot JR. Identification of patients at risk of sudden cardiac death in congenital heart disease: The PRospEctiVE study on implaNTable cardIOverter defibrillator therapy and suddeN cardiac death in Adults with Congenital Heart Disease (PREVENTION-ACHD). Heart Rhythm 2021; 18:785-792. [PMID: 33465514 DOI: 10.1016/j.hrthm.2021.01.009] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/16/2020] [Revised: 12/27/2020] [Accepted: 01/10/2021] [Indexed: 11/29/2022]
Abstract
BACKGROUND Sudden cardiac death (SCD) is the main preventable cause of death in patients with adult congenital heart disease (ACHD). Since robust risk stratification methods are lacking, we developed a risk score model to predict SCD in patients with ACHD: the PRospEctiVE study on implaNTable cardIOverter defibrillator therapy and suddeN cardiac death in Adults with Congenital Heart Disease (PREVENTION-ACHD) risk score model. OBJECTIVE The purpose of this study was to prospectively study predicted SCD risk using the PREVENTION-ACHD risk score model and actual SCD and sustained ventricular tachycardia/ventricular fibrillation (VT/VF) rates in patients with ACHD. METHODS The PREVENTION-ACHD risk score model assigns 1 point each to coronary artery disease, New York Heart Association class II/III heart failure, supraventricular tachycardia, systemic ejection fraction < 40%, subpulmonary ejection fraction < 40%, QRS duration ≥ 120 ms, and QT dispersion ≥ 70 ms. SCD risk was calculated for each patient. An annual predicted risk of ≥3% constituted high risk. The primary outcome was SCD or VT/VF after 2 years. The secondary outcome was SCD. RESULTS The study included 783 consecutive patients with ACHD (n=239 (31%) left-sided lesions; n=138 (18%) tetralogy of Fallot; n=108 (14%) closed atrial septal defect; median age 36 years; interquartile range 28-47 years; n=401 (51%) men). The PREVENTION-ACHD risk score model identified 58 high-risk patients. Eight patients (4 at high risk) experienced the primary outcome. The Kaplan-Meier estimates were 7% (95% confidence interval [CI] 0.1%-13.3%) in the high-risk group and 0.6% (95% CI 0.0%-1.1%) in the low-risk group (hazard ratio 12.5; 95% CI 3.1-50.9; P < .001). The risk score model's sensitivity was 0.5 and specificity 0.93, resulting in a C-statistic of 0.75 (95% CI 0.57-0.90). The hazard ratio for SCD was 12.4 (95% CI 1.8-88.1) (P = .01); the sensitivity and specificity were 0.5 and 0.92, and the C-statistic was 0.81 (95% CI 0.67-0.95). CONCLUSION The PREVENTION-ACHD risk score model provides greater accuracy in SCD or VT/VF risk stratification as compared with current guideline indications and identifies patients with ACHD who may benefit from preventive implantable cardioverter-defibrillator implantation.
Collapse
|
59
|
Merino JL, Lip GYH, Heidbuchel H, Cohen AA, De Caterina R, de Groot JR, Ezekowitz MD, Le Heuzey JY, Themistoclakis S, Jin J, Melino M, Winters SM, Merkely B, Goette A. Determinants of left atrium thrombi in scheduled cardioversion: an ENSURE-AF study analysis. Europace 2020; 21:1633-1638. [PMID: 31436835 PMCID: PMC6826208 DOI: 10.1093/europace/euz213] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2019] [Accepted: 08/07/2019] [Indexed: 12/17/2022] Open
Abstract
Aims ENSURE-AF (NCT 02072434) was the largest prospective randomized clinical trial of anticoagulation for cardioversion in atrial fibrillation (AF), which also provides the largest prospective dataset for transoesophageal echocardiography (TOE) prior to cardioversion. This ancillary analysis investigated determinants of TOE-detected left atrium thrombi (LAT) in patients scheduled for electrical cardioversion (ECV). Methods and results The ENSURE-AF multicentre PROBE evaluation trial compared edoxaban 60 mg once daily (QD) with enoxaparin/warfarin in 2199 subjects undergoing ECV of non-valvular AF. Patients were stratified by the use of TOE, anticoagulant experience, and selected edoxaban dose. Electrical cardioversion was cancelled or deferred when TOEdetected LAT. In total, 1183 subjects were stratified to the TOE arm and LAT was reported in 91 (8.2%). In univariate analysis, age ≥75 years (26.4% vs. 16.9%, P = 0.0308), lower weight (86.5 ± 15.0 vs. 90.7 ± 18.0 kg, P = 0.0309), lower creatinine clearance (80.1 ± 30.6 vs. 93.2 ± 33.9 mL/min, P = 0.0007), heart failure (59.3% vs. 43.0%, P = 0.0029), and diuretic treatment (53.9% vs. 40.1%, P = 0.0141) were more prevalent in the LAT group. Non-significant trends were seen for higher mean CHA2DS2-VASc score (3.0 ± 1.41 vs. 2.7 ± 1.48, P = 0.0571) and more prevalent anticoagulation use prior to enrolment (60.4% vs. 50.3%, P = 0.0795) in the LAT group. In logistic regression analysis, age (P = 0.0202) and heart failure (P = 0.0064) were independently associated with LAT. Conclusion Elective ECV is commonly cancelled or deferred due to TOE-detected LAT in patients with non-valvular AF. Age ≥75 years and heart failure were associated with the presence of LAT.
Collapse
|
60
|
Mol D, Houterman S, Balt JC, Bhagwandien RE, Blaauw Y, Delnoy PPH, van Driel VJ, Driessen AH, Folkeringa RJ, Hassink RJ, van Huysduynen BH, Luermans JG, Ouss AJ, Stevenhagen YJ, van Veghel D, Westra SW, de Jong JS, de Groot JR. Complications in pulmonary vein isolation in the Netherlands Heart Registration differ with sex and ablation technique. Europace 2020; 23:216-225. [DOI: 10.1093/europace/euaa255] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2020] [Accepted: 07/27/2020] [Indexed: 12/31/2022] Open
Abstract
Abstract
Aims
Pulmonary vein isolation (PVI) has become a cornerstone of the invasive treatment of atrial fibrillation. Severe complications are reported in 1–3% of patients. This study aims to compare complications and follow-up outcome of PVI in patients with atrial fibrillation.
Methods and results
The data were extracted from the Netherlands Heart Registration. Procedural and follow-up outcomes in patients treated with conventional radiofrequency (C-RF), multielectrode phased RF (Ph-RF), or cryoballoon (CB) ablation from 2012 to 2017 were compared. Subgroup analysis was performed to identify variables associated with complications and repeat ablations. In total, 13 823 patients (69% male) were included. The reported complication incidence was 3.6%. Patients treated with C-RF developed more cardiac tamponades (C-RF 0.8% vs. Ph-RF 0.3% vs. CB 0.3%, P ≤ 0.001) and vascular complications (C-RF 1.7% vs. Ph-RF 1.2% vs. CB 1.3%, P ≤ 0.001). Ph-RF was associated with fewer bleeding complications (C-RF: 1.0% vs. Ph-RF: 0.4% vs. CB: 0.7%, P = 0.020). Phrenic nerve palsy mainly occurred in patients treated with CB (C-RF: 0.1% vs. Ph-RF: 0.2% vs. CB: 1.5%, P ≤ 0.001). In total, 18.4% of patients were referred for repeat ablation within 1 year. Female sex, age, and CHA2DS2-VASc were independent risk factors for cardiac tamponade and bleeding complications, with an adjusted OR for female patients of 2.97 (95% CI 1.98–4.45) and 2.02 (95% CI 1.03–4.00) respectively.
Conclusion
The reported complication rate during PVI was low. Patients treated with C-RF ablation were more likely to develop cardiac tamponades and vascular complications. Female sex was associated with more cardiac tamponade and bleeding complications.
Collapse
|
61
|
Bertaglia E, Blank B, Blomström-Lundqvist C, Brandes A, Cabanelas N, Dan GA, Dichtl W, Goette A, de Groot JR, Lubinski A, Marijon E, Merkely B, Mont L, Piorkowski C, Sarkozy A, Sulke N, Vardas P, Velchev V, Wichterle D, Kirchhof P. Atrial high-rate episodes: prevalence, stroke risk, implications for management, and clinical gaps in evidence. Europace 2020; 21:1459-1467. [PMID: 31377792 PMCID: PMC6788209 DOI: 10.1093/europace/euz172] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2019] [Accepted: 07/15/2019] [Indexed: 12/20/2022] Open
Abstract
Self-terminating atrial arrhythmias are commonly detected on continuous rhythm monitoring, e.g. by pacemakers or defibrillators. It is unclear whether the presence of these arrhythmias has therapeutic consequences. We sought to summarize evidence on the prevalence of atrial high-rate episodes (AHREs) and their impact on risk of stroke. We performed a comprehensive, tabulated review of published literature on the prevalence of AHRE. In patients with AHRE, but without atrial fibrillation (AF), we reviewed the stroke risk and the potential risk/benefit of oral anticoagulation. Atrial high-rate episodes are found in 10–30% of AF-free patients. Presence of AHRE slightly increases stroke risk (0.8% to 1%/year) compared with patients without AHRE. Atrial high-rate episode of longer duration (e.g. those >24 h) could be associated with a higher stroke risk. Oral anticoagulation has the potential to reduce stroke risk in patients with AHRE but is associated with a rate of major bleeding of 2%/year. Oral anticoagulation is not effective in patients with heart failure or survivors of a stroke without AF. It remains unclear whether anticoagulation is effective and safe in patients with AHRE. Atrial high-rate episodes are common and confer a slight increase in stroke risk. There is true equipoise on the best way to reduce stroke risk in patients with AHRE. Two ongoing trials (NOAH-AFNET 6 and ARTESiA) will provide much-needed information on the effectiveness and safety of oral anticoagulation using non-vitamin K antagonist oral anticoagulants in patients with AHRE.
Collapse
|
62
|
Baalman SW, Schroevers FE, Oakley AJ, Brouwer TF, van der Stuijt W, Bleijendaal H, Ramos LA, Lopes RR, Marquering HA, Knops RE, de Groot JR. A morphology based deep learning model for atrial fibrillation detection using single cycle electrocardiographic samples. Int J Cardiol 2020; 316:130-136. [DOI: 10.1016/j.ijcard.2020.04.046] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2020] [Revised: 04/03/2020] [Accepted: 04/16/2020] [Indexed: 10/24/2022]
|
63
|
Mol D, Riezebos RK, Marquering HA, Werner ME, Lobban TC, de Jong JS, de Groot JR. Performance of an automated photoplethysmography-based artificial intelligence algorithm to detect atrial fibrillation. CARDIOVASCULAR DIGITAL HEALTH JOURNAL 2020; 1:107-110. [PMID: 35265881 PMCID: PMC8890349 DOI: 10.1016/j.cvdhj.2020.08.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
|
64
|
Chu G, Seelig J, Trinks-Roerdink EM, van Alem AP, Alings M, van den Bemt B, Boersma LV, Brouwer MA, Cannegieter SC, Ten Cate H, Kirchhof CJ, Crijns HJ, van Dijk EJ, Elvan A, van Gelder IC, de Groot JR, den Hartog FR, de Jong JS, de Jong S, Klok FA, Lenderink T, Luermans JG, Meeder JG, Pisters R, Polak P, Rienstra M, Smeets F, Tahapary GJ, Theunissen L, Tieleman RG, Trines SA, van der Voort P, Geersing GJ, Rutten FH, Hemels ME, Huisman MV. Design and rationale of DUTCH-AF: a prospective nationwide registry programme and observational study on long-term oral antithrombotic treatment in patients with atrial fibrillation. BMJ Open 2020; 10:e036220. [PMID: 32843516 PMCID: PMC7449286 DOI: 10.1136/bmjopen-2019-036220] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/21/2023] Open
Abstract
INTRODUCTION Anticoagulation therapy is pivotal in the management of stroke prevention in atrial fibrillation (AF). Prospective registries, containing longitudinal data are lacking with detailed information on anticoagulant therapy, treatment adherence and AF-related adverse events in practice-based patient cohorts, in particular for non-vitamin K oral anticoagulants (NOAC). With the creation of DUTCH-AF, a nationwide longitudinal AF registry, we aim to provide clinical data and answer questions on the (anticoagulant) management over time and of the clinical course of patients with newly diagnosed AF in routine clinical care. Within DUTCH-AF, our current aim is to assess the effect of non-adherence and non-persistence of anticoagulation therapy on clinical adverse events (eg, bleeding and stroke), to determine predictors for such inadequate anticoagulant treatment, and to validate and refine bleeding prediction models. With DUTCH-AF, we provide the basis for a continuing nationwide AF registry, which will facilitate subsequent research, including future registry-based clinical trials. METHODS AND ANALYSIS The DUTCH-AF registry is a nationwide, prospective registry of patients with newly diagnosed 'non-valvular' AF. Patients will be enrolled from primary, secondary and tertiary care practices across the Netherlands. A target of 6000 patients for this initial cohort will be followed for at least 2 years. Data on thromboembolic and bleeding events, changes in antithrombotic therapy and hospital admissions will be registered. Pharmacy-dispensing data will be obtained to calculate parameters of adherence and persistence to anticoagulant treatment, which will be linked to AF-related outcomes such as ischaemic stroke and major bleeding. In a subset of patients, anticoagulation adherence and beliefs about drugs will be assessed by questionnaire. ETHICS AND DISSEMINATION This study protocol was approved as exempt for formal review according to Dutch law by the Medical Ethics Committee of the Leiden University Medical Centre, Leiden, the Netherlands. Results will be disseminated by publications in peer-reviewed journals and presentations at scientific congresses. TRIAL REGISTRATION NUMBER Trial NL7467, NTR7706 (https://www.trialregister.nl/trial/7464).
Collapse
|
65
|
Reyat JS, Chua W, Cardoso VR, Witten A, Kastner PM, Kabir SN, Sinner MF, Wesselink R, Holmes AP, Pavlovic D, Stoll M, Kääb S, Gkoutos GV, de Groot JR, Kirchhof P, Fabritz L. Reduced left atrial cardiomyocyte PITX2 and elevated circulating BMP10 predict atrial fibrillation after ablation. JCI Insight 2020; 5:139179. [PMID: 32814717 PMCID: PMC7455124 DOI: 10.1172/jci.insight.139179] [Citation(s) in RCA: 40] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Accepted: 07/08/2020] [Indexed: 11/17/2022] Open
Abstract
BACKGROUNDGenomic and experimental studies suggest a role for PITX2 in atrial fibrillation (AF). To assess if this association is relevant for recurrent AF in patients, we tested whether left atrial PITX2 affects recurrent AF after AF ablation.METHODSmRNA concentrations of PITX2 and its cardiac isoform, PITX2c, were quantified in left atrial appendages (LAAs) from patients undergoing thoracoscopic AF ablation, either in whole LAA tissue (n = 83) or in LAA cardiomyocytes (n = 52), and combined with clinical parameters to predict AF recurrence. Literature suggests that BMP10 is a PITX2-repressed, atrial-specific, secreted protein. BMP10 plasma concentrations were combined with 11 cardiovascular biomarkers and clinical parameters to predict recurrent AF after catheter ablation in 359 patients.RESULTSReduced concentrations of cardiomyocyte PITX2, but not whole LAA tissue PITX2, were associated with AF recurrence after thoracoscopic AF ablation (16% decreased recurrence per 2-(ΔΔCt) increase in PITX2). RNA sequencing, quantitative PCR, and Western blotting confirmed that BMP10 is one of the most PITX2-repressed atrial genes. Left atrial size (HR per mm increase [95% CI], 1.055 [1.028, 1.082]); nonparoxysmal AF (HR 1.672 [1.206, 2.318]), and elevated BMP10 (HR 1.339 [CI 1.159, 1.546] per quartile increase) were predictive of recurrent AF. BMP10 outperformed 11 other cardiovascular biomarkers in predicting recurrent AF.CONCLUSIONSReduced left atrial cardiomyocyte PITX2 and elevated plasma concentrations of the PITX2-repressed, secreted atrial protein BMP10 identify patients at risk of recurrent AF after ablation.TRIAL REGISTRATIONClinicalTrials.gov NCT01091389, NL50069.018.14, Dutch National Registry of Clinical Research Projects EK494-16.FUNDINGBritish Heart Foundation, European Union (H2020), Leducq Foundation.
Collapse
|
66
|
de Groot JR, Weiss TW, Kelly P, Monteiro P, Deharo JC, de Asmundis C, López-de-Sá E, Waltenberger J, Steffel J, Levy P, Bakhai A, Zierhut W, Laeis P, Manu MC, Reimitz PE, De Caterina R, Kirchhof P. Edoxaban for stroke prevention in atrial fibrillation in routine clinical care: 1-year follow-up of the prospective observational ETNA-AF-Europe study. EUROPEAN HEART JOURNAL. CARDIOVASCULAR PHARMACOTHERAPY 2020; 7:f30-f39. [PMID: 32790837 PMCID: PMC8117428 DOI: 10.1093/ehjcvp/pvaa079] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/09/2020] [Revised: 05/28/2020] [Accepted: 08/05/2020] [Indexed: 01/16/2023]
Abstract
Aims Non-vitamin K oral anticoagulants are safe and effective for stroke prevention in patients with atrial fibrillation (AF). Data on the safety and efficacy of edoxaban in routine care are limited in Europe. We report 1-year outcomes in patients with AF treated with edoxaban in routine care. Methods and results ETNA-AF-Europe is a prospective, multicentre, post-authorization, observational study enrolling patients treated with edoxaban in 10 European countries, the design of which was agreed with the European Medicines Agency as part of edoxaban’s post-approval safety plan. Altogether 13 092 patients in 852 sites completed the 1-year follow-up [mean age: 73.6 ± 9.5 years; 57% male, mean follow-up: 352 ± 49 days (median: 366 days)]. Most patients had associated comorbidities (mean CHA2DS2-VASc score: 3.1 ± 1.4). Stroke or systemic embolism was reported in 103 patients (annualized event rate: 0.82%/year), and major bleeding events were reported in 132 patients (1.05%/year). Rates of intracranial haemorrhage were low [30 patients (0.24%/year)]. Death occurred in 442 patients (3.50%/year); cardiovascular (CV) death occurred in 206 patients (1.63%/year). The approved dosing of edoxaban was chosen in 83%. All-cause and CV mortality were higher in patients receiving edoxaban 30 mg vs. 60 mg, in line with the higher age and more frequent comorbidities of the 30 mg group. Major bleeding was also numerically more common in patients receiving edoxaban 30 mg vs. 60 mg. Conclusion The rates of stroke, systemic embolism, and major bleeding are low in this large unselected cohort of high-risk AF patients routinely treated with edoxaban.
Collapse
|
67
|
van der Stuijt W, Baalman SWE, Brouwer TF, Quast AFBE, de Groot JR, Knops RE. Long-term follow-up of the two-incision implantation technique for the subcutaneous implantable cardioverter-defibrillator. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2020; 43:1476-1480. [PMID: 32720398 PMCID: PMC7754287 DOI: 10.1111/pace.14022] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/25/2020] [Revised: 07/24/2020] [Accepted: 07/26/2020] [Indexed: 11/30/2022]
Abstract
Introduction The two‐incision implantation technique of the subcutaneous implantable cardioverter‐defibrillator (S‐ICD) was introduced as an alternative to the standard three‐incision approach by omitting the superior parasternal incision. Thereby, complications may be prevented. Short‐term follow‐up demonstrated the safety and efficacy of the two‐incision technique. However, long‐term results are lacking. Methods This retrospective study included patients implanted between February 2009 and June 2020. Patients were divided into a group of patients who were implanted with the standard three‐incision technique and a group who were implanted with the two‐incision technique. Outcomes were defibrillation impedance and efficacy and complications requiring intervention. Results A total of 268 patients were included (age 42.4 ± 16.6 years, 35.4% female, BMI 25.1 ± 4.5 kg/m2). Thirty‐one patients underwent S‐ICD implantation with the three‐incision technique and 237 patients with the two‐incision technique. First shock efficacy during defibrillation testing was 93% in the three‐incision group versus 94% in the two‐incision group (P = .69), and shock impedance was 85 versus 68 ohms (P = .04). First shock success was 75% versus 76% for spontaneous episodes (P = 1.00). Complication‐free survival at 5‐year follow‐up in the three‐incision group was estimated at 0.96 (95% CI 0.90‐1.00) versus 0.98 (95% CI 0.96‐1.00) in the two‐incision group (P = .20) and for inappropriate shocks at 5‐year 0.77 (95% CI 0.63‐0.94) versus 0.83 (95% CI 0.77‐0.89, P = .30), respectively. Conclusion Five‐year follow‐up in this S‐ICD cohort showed similar complication rates and effectiveness of two‐incision technique compared to the three‐incision technique. This technique offers physicians a less invasive and more simplified implantation procedure for the S‐ICD, with a better cosmetic result.
Collapse
|
68
|
Knops RE, Olde Nordkamp LRA, Delnoy PPHM, Boersma LVA, Kuschyk J, El-Chami MF, Bonnemeier H, Behr ER, Brouwer TF, Kääb S, Mittal S, Quast AFBE, Smeding L, van der Stuijt W, de Weger A, de Wilde KC, Bijsterveld NR, Richter S, Brouwer MA, de Groot JR, Kooiman KM, Lambiase PD, Neuzil P, Vernooy K, Alings M, Betts TR, Bracke FALE, Burke MC, de Jong JSSG, Wright DJ, Tijssen JGP, Wilde AAM. Subcutaneous or Transvenous Defibrillator Therapy. N Engl J Med 2020; 383:526-536. [PMID: 32757521 DOI: 10.1056/nejmoa1915932] [Citation(s) in RCA: 261] [Impact Index Per Article: 65.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
BACKGROUND The subcutaneous implantable cardioverter-defibrillator (ICD) was designed to avoid complications related to the transvenous ICD lead by using an entirely extrathoracic placement. Evidence comparing these systems has been based primarily on observational studies. METHODS We conducted a noninferiority trial in which patients with an indication for an ICD but no indication for pacing were assigned to receive a subcutaneous ICD or transvenous ICD. The primary end point was the composite of device-related complications and inappropriate shocks; the noninferiority margin for the upper boundary of the 95% confidence interval for the hazard ratio (subcutaneous ICD vs. transvenous ICD) was 1.45. A superiority analysis was prespecified if noninferiority was established. Secondary end points included death and appropriate shocks. RESULTS A total of 849 patients (426 in the subcutaneous ICD group and 423 in the transvenous ICD group) were included in the analyses. At a median follow-up of 49.1 months, a primary end-point event occurred in 68 patients in the subcutaneous ICD group and in 68 patients in the transvenous ICD group (48-month Kaplan-Meier estimated cumulative incidence, 15.1% and 15.7%, respectively; hazard ratio, 0.99; 95% confidence interval [CI], 0.71 to 1.39; P = 0.01 for noninferiority; P = 0.95 for superiority). Device-related complications occurred in 31 patients in the subcutaneous ICD group and in 44 in the transvenous ICD group (hazard ratio, 0.69; 95% CI, 0.44 to 1.09); inappropriate shocks occurred in 41 and 29 patients, respectively (hazard ratio, 1.43; 95% CI, 0.89 to 2.30). Death occurred in 83 patients in the subcutaneous ICD group and in 68 in the transvenous ICD group (hazard ratio, 1.23; 95% CI, 0.89 to 1.70); appropriate shocks occurred in 83 and 57 patients, respectively (hazard ratio, 1.52; 95% CI, 1.08 to 2.12). CONCLUSIONS In patients with an indication for an ICD but no indication for pacing, the subcutaneous ICD was noninferior to the transvenous ICD with respect to device-related complications and inappropriate shocks. (Funded by Boston Scientific; PRAETORIAN ClinicalTrials.gov number, NCT01296022.).
Collapse
|
69
|
van der Ree MH, Blanck O, Limpens J, Lee CH, Balgobind BV, Dieleman EM, Wilde AA, Zei PC, de Groot JR, Slotman BJ, Cuculich PS, Robinson CG, Postema PG. Cardiac radioablation—A systematic review. Heart Rhythm 2020; 17:1381-1392. [DOI: 10.1016/j.hrthm.2020.03.013] [Citation(s) in RCA: 43] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/10/2019] [Accepted: 03/13/2020] [Indexed: 12/29/2022]
|
70
|
Baalman SWE, Mittal S, Boersma LVA, Perschbacher D, Brisben AJ, Mahajan D, de Groot JR, Knops RE. Real-world performance of the atrial fibrillation monitor in patients with a subcutaneous ICD. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2020; 43:1467-1475. [PMID: 32662101 PMCID: PMC7754353 DOI: 10.1111/pace.14010] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/13/2020] [Revised: 07/09/2020] [Accepted: 07/12/2020] [Indexed: 12/19/2022]
Abstract
Introduction The third‐generation subcutaneous implantable cardioverter‐defibrillator (S‐ICD) (EMBLEM™ A219, Boston Scientific) contains a new diagnostic tool to detect atrial fibrillation (AF) in S‐ICD patients, without the use of an intracardiac lead. This is the first study to evaluate the performance of the S‐ICD AF monitor (AFM). Methods The AFM algorithm analyzes a subcutaneous signal for the presence of AF, similar to the signals collected by implantable and wearable diagnostic devices. The AFM algorithm combines heart rate (HR) scatter analysis with an HR histogram. The algorithm was tested against publicly available electrocardiogram databases (simulated performance). Real‐world performance of the algorithm was evaluated by using the S‐ICD LATITUDE remote monitoring (RM) database. Results The simulated performance of the AFM algorithm resulted in a sensitivity of 95.0%, specificity of 100.0%, and positive predictive value (PPV) of 100.0%. To evaluate the real‐world performance of the AFM, 7744 S‐ICD devices were followed for up to 30 months by RM, whereof 99.5% had the AFM enabled. A total of 387 AF episodes were randomly chosen for adjudication, resulting in a PPV of 67.7%. The main cause of misclassification was atrial and ventricular ectopy. Conclusion The AFM exhibited a very high sensitivity and specificity in a simulated setting, designed to maximize PPV in order to minimize the clinical burden of reviewing falsely detected AF events. The real‐world performance of the AFM, enabled in 99.5% of S‐ICD patients, is a PPV of 67.7%.
Collapse
|
71
|
Neefs J, Ons SA, Berger WR, Krul SPJ, van den Berg NWE, Piersma FR, Beijk MAM, van Boven WP, Driessen AHG, de Groot JR. Clinical course of sinus node dysfunction after thoracoscopic surgery for atrial fibrillation-analysis of the Atrial Fibrillation Ablation and Autonomic Modulation via Thoracoscopic Surgery (AFACT) study. J Interv Card Electrophysiol 2020; 60:185-193. [PMID: 32172425 PMCID: PMC7925456 DOI: 10.1007/s10840-020-00722-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/13/2020] [Accepted: 02/23/2020] [Indexed: 11/28/2022]
Abstract
PURPOSE Sinus node dysfunction (SND) may complicate thoracoscopic surgical atrial fibrillation (AF) ablation. Identifying patients at risk is important, as SND may require temporary or permanent pacing. To determine the incidence of postoperative SND and duration of symptoms in patients who underwent thoracoscopic surgical ablation. METHODS Patients with paroxysmal or persistent AF included in the Atrial Fibrillation Ablation and Autonomic Modulation via Thoracoscopic Surgery (AFACT) study underwent pulmonary vein isolation and additional left atrial ablations on indication. Patients were randomized to ganglion plexus ablation or control. SND was defined as symptomatic or asymptomatic junctional rhythm exceeding sinus rate within 30 days postoperatively. The SND risk was assessed by using a univariable logistic regression model. The rate of pacemaker implantation was determined. RESULTS The AFACT study included 240 patients. SND developed in 17 (7.1%) patients, not affected by randomized treatment, p = 0.18. SND patients more often had persistent AF (88.2%) than patients without SND (57.4%), p = 0.01. After univariable testing, persistent AF (OR 5.57 CI 1.52-35.90, p = 0.02) and additional left atrial ablations (OR 12.10 CI 2.40-220.20, p = 0.02) were associated with postoperative SND. Six (35.3%) patients needed temporary pacing for 1-7 days; permanent pacemakers (PMs) were implanted for SND in five (29.4%) patients. CONCLUSION Additional left atrial ablations strongly increase the SND risk. The majority of SND was temporary, and sinus rhythm resolved within days, which indicates that a conservative approach with regard to pacemaker implantation should be considered.
Collapse
|
72
|
Neefs J, van den Berg NWE, Krul SPJ, Boekholdt SM, de Groot JR. Effect of Spironolactone on Atrial Fibrillation in Patients with Heart Failure with Preserved Ejection Fraction: Post-Hoc Analysis of the Randomized, Placebo-Controlled TOPCAT Trial. Am J Cardiovasc Drugs 2020; 20:73-80. [PMID: 31214914 PMCID: PMC6978290 DOI: 10.1007/s40256-019-00353-5] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Background Mineralocorticoid receptor antagonists (MRAs) reduce the risk of atrial fibrillation (AF) in patients with heart failure (HF) and a reduced ejection fraction. The efficacy of MRAs for AF prevention in patients with HF and a preserved ejection fraction (HFpEF) is unclear. Objectives We performed a secondary analysis of a randomized placebo-controlled trial to determine the efficacy of spironolactone in reducing new-onset AF and recurrence of AF in 2733 patients with symptomatic HFpEF. Methods Patients with and without prevalent AF at baseline were included, and those with permanent AF were excluded. Patients were randomized 1:1 to spironolactone or placebo. The risk of new-onset AF or the recurrence of AF was quantified using hazard ratios (HRs) with corresponding 95% confidence intervals (CIs). Results At baseline, 2228 (64.7%) patients had no history of AF (spironolactone, n = 1111; placebo, n = 1117), whereas 505 (18.4%) patients had prevalent AF (spironolactone, n = 260; placebo, n = 245). During a median follow-up of 3.1 years (interquartile range [IQR] 2.0–4.9), the incidence of new-onset AF was similar in both treatment arms: spironolactone 5.2% (n = 58) versus placebo 4.4% (n = 49); p = 0.41. The risk of new-onset AF was similar in both treatment arms: HR 1.19; 95% CI 0.81–1.74; p = 0.38. AF recurrence was also similar in both treatment arms during a median follow-up of 3.3 years (IQR 1.9–4.7): spironolactone 11.5% (n = 30) versus placebo 11.8% (n = 29); p = 1.00. The risk of recurrence of AF did not differ per treatment arm: HR 0.94; 95% CI 0.57–1.58; p = 0.83. Conclusion Spironolactone does not reduce the risk of new-onset AF or AF recurrence in patients with HFpEF. This is in contrast to results in cohorts of patients with HF and a reduced ejection fraction. Clinical trial registration ClinicalTrials.gov identifier no. NCT00094302 (TOPCAT). Electronic supplementary material The online version of this article (10.1007/s40256-019-00353-5) contains supplementary material, which is available to authorized users.
Collapse
|
73
|
van Dijk VF, Quast AFBE, Schaap J, Balt JC, Kelder JC, Wijffels MCEF, de Groot JR, Boersma LVA. ICD implantation for secondary prevention in patients with ventricular arrhythmia in the setting of acute cardiac ischemia and a history of myocardial infarction. J Cardiovasc Electrophysiol 2020; 31:536-543. [PMID: 31944462 DOI: 10.1111/jce.14357] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/19/2019] [Revised: 12/13/2019] [Accepted: 12/17/2019] [Indexed: 11/28/2022]
Abstract
INTRODUCTION In patients with a prior myocardial infarction (MI) but preserved left ventricular (LV) function, sustained ventricular arrhythmias (VAs) may arise in the setting of an acute coronary syndrome (ACS). It is unknown whether an implantable cardioverter-defibrillator (ICD) is mandatory in these patients as VA might be triggered by a reversible cause. The purpose of this study is to analyze the benefit of ICD therapy in this patient population. METHODS We conducted a retrospective observational study in ICD recipients implanted from 2008 to 2011. The study group consisted of patients with sustained VA in the setting of an ACS, with a history of MI, but with left ventricular ejection fraction (LVEF) greater than 35 (group A). The two control groups consisted of patients admitted with VA with a history of MI, but without ACS at presentation, either with LVEF greater than 35% (group B) or ≤35% (group C). The primary endpoint was the number of patients with appropriate ICD therapy (antitachycardia pacing or shock). RESULTS A total of 291 patients were included with a mean follow-up of 5.3 years. Appropriate ICD therapy occurred in 45.6% of the patients in group A vs 51.6% and 60.4% in groups B and C (P = .11). In group A, 31.1% received an appropriate ICD shock vs 34.7% and 44.3% in control groups B and C (P = .12). CONCLUSION On the basis of these data, ICD implantation seems warranted in patients with history of MI presenting with VA in the setting of an ACS, despite preserved LV function and adequate revascularization. Further trials, preferably randomizes, should be performed to address these findings.
Collapse
|
74
|
Casini S, Marchal GA, Kawasaki M, Nariswari FA, Portero V, van den Berg NWE, Guan K, Driessen AHG, Veldkamp MW, Mengarelli I, de Groot JR, Verkerk AO, Remme CA. Absence of Functional Na v1.8 Channels in Non-diseased Atrial and Ventricular Cardiomyocytes. Cardiovasc Drugs Ther 2019; 33:649-660. [PMID: 31916131 PMCID: PMC6994555 DOI: 10.1007/s10557-019-06925-6] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
PURPOSE Several studies have indicated a potential role for SCN10A/NaV1.8 in modulating cardiac electrophysiology and arrhythmia susceptibility. However, by which mechanism SCN10A/NaV1.8 impacts on cardiac electrical function is still a matter of debate. To address this, we here investigated the functional relevance of NaV1.8 in atrial and ventricular cardiomyocytes (CMs), focusing on the contribution of NaV1.8 to the peak and late sodium current (INa) under normal conditions in different species. METHODS The effects of the NaV1.8 blocker A-803467 were investigated through patch-clamp analysis in freshly isolated rabbit left ventricular CMs, human left atrial CMs and human-induced pluripotent stem cell-derived CMs (hiPSC-CMs). RESULTS A-803467 treatment caused a slight shortening of the action potential duration (APD) in rabbit CMs and hiPSC-CMs, while it had no effect on APD in human atrial cells. Resting membrane potential, action potential (AP) amplitude, and AP upstroke velocity were unaffected by A-803467 application. Similarly, INa density was unchanged after exposure to A-803467 and NaV1.8-based late INa was undetectable in all cell types analysed. Finally, low to absent expression levels of SCN10A were observed in human atrial tissue, rabbit ventricular tissue and hiPSC-CMs. CONCLUSION We here demonstrate the absence of functional NaV1.8 channels in non-diseased atrial and ventricular CMs. Hence, the association of SCN10A variants with cardiac electrophysiology observed in, e.g. genome wide association studies, is likely the result of indirect effects on SCN5A expression and/or NaV1.8 activity in cell types other than CMs.
Collapse
|
75
|
Yang H, Nassif M, Khairy P, de Groot JR, Roos YBWEM, de Winter RJ, Mulder BJM, Bouma BJ. Cardiac diagnostic work-up of ischaemic stroke. Eur Heart J 2019; 39:1851-1860. [PMID: 29788298 DOI: 10.1093/eurheartj/ehy043] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/06/2016] [Accepted: 08/17/2016] [Indexed: 12/20/2022] Open
Abstract
Cardioembolic sources account for 20-30% of ischaemic strokes and are important to identify considering their prognostic and therapeutic implications. During the past years, new developments have been made in the cardiac diagnostic evaluation and management of patients with ischaemic stroke, especially regarding strokes of unknown aetiology. These recent advances have had a major impact on our understanding of embolic strokes, their diagnostic work-up, and clinical management. Herein, we propose a cardiac diagnostic work-up scheme for patients with ischaemic stroke from definite cardioembolic sources and embolic strokes of undetermined source.
Collapse
|