51
|
Saarinen K, Swan H, Kainulainen K, Toivonen L, Viitasalo M, Kontula K. Molecular genetics of the long QT syndrome: two novel mutations of the KVLQT1 gene and phenotypic expression of the mutant gene in a large kindred. Hum Mutat 2000; 11:158-65. [PMID: 9482580 DOI: 10.1002/(sici)1098-1004(1998)11:2<158::aid-humu9>3.0.co;2-f] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
At least three different gene loci were recently shown to account for the long QT syndrome (LQTS), a monogenic disorder with altered myocardial repolarization and occurrence of life-threatening cardiac arrhythmias. We screened 44 unrelated probands for mutations of the gene encoding the cardiac potassium channel KVLQT1 using single-strand conformational polymorphism (SSCP) and subsequent DNA sequencing. Two different mutations, T182I and D188N, were identified in two separate pedigrees. Cosegregation of the mutation with the disease phenotype was evident in both families. No mutations were identified at codon 212, previously suggested to represent a mutational hot spot of the KVLQT1 channel, in any of the 44 probands. The large pedigree with the D188N mutation (30 affected and 43 nonaffected individuals) permitted an analysis of expression of the mutant gene in its documented carriers. Although the mean (+/-SD) QTc interval was markedly longer in affected (484+/-38 ms) than in nonaffected individuals (406+/-27 ms, P < 0.001), there was a marked overlapping of individual values in these two groups. QTc values in symptomatic and asymptomatic carriers of the mutant gene were not significantly different. In conclusion, we have identified two novel mutations of the KVLQT1 component of a cardiac potassium channel. Our data support the functional significance of the pore-S6 domain of this membrane protein and emphasize the diagnostic usefulness of DNA analyses in families with LQTS.
Collapse
|
52
|
Piippo K, Laitinen P, Swan H, Toivonen L, Viitasalo M, Pasternack M, Paavonen K, Chapman H, Wann KT, Hirvelä E, Sajantila A, Kontula K. Homozygosity for a HERG potassium channel mutation causes a severe form of long QT syndrome: identification of an apparent founder mutation in the Finns. J Am Coll Cardiol 2000; 35:1919-25. [PMID: 10841244 DOI: 10.1016/s0735-1097(00)00636-7] [Citation(s) in RCA: 44] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
OBJECTIVES We studied the clinical characteristics and molecular background underlying a severe phenotype of long QT syndrome (LQTS). BACKGROUND Mutations of cardiac ion channel genes cause LQTS, manifesting as increased risk of ventricular tachycardia and sudden death. METHODS We studied two siblings showing prolonged QT intervals corrected for heart rate (QTc), their asymptomatic parents with only marginally prolonged QTc intervals and their family members. The potassium channel gene HERG was screened for mutations by deoxyribonucleic acid sequencing, and the electrophysiologic consequences of the mutation were studied in vitro using the whole-cell patch-clamp technique. RESULTS A novel missense mutation (L552S) in the HERG channel, present in the homozygous state in the affected siblings and in the heterozygous state in their parents, as well as in 38 additional subjects from six LQTS families, was identified. One of the homozygous siblings had 2:1 atrioventricular block immediately after birth, and died at the age of four years after experiencing unexplained hypoglycemia. The other sibling had an episode of torsade de pointes at the age of two years. The mean QTc interval differed significantly (p < 0.001) between heterozygous symptomatic mutation carriers (500 +/- 59 ms), asymptomatic mutation carriers (452 +/- 34 ms) and noncarriers (412 +/- 23 ms). When expressed in vitro, the HERG-L552S formed functional channels with increased activation and deactivation rates. CONCLUSIONS Our data demonstrate that homozygosity for a HERG mutation can cause a severe cardiac repolarization disorder without other phenotypic abnormalities. Absence of functional HERG channels appears to be one cause for intrauterine and neonatal bradycardia and 2:1 atrioventricular block.
Collapse
|
53
|
Laitinen P, Fodstad H, Piippo K, Swan H, Toivonen L, Viitasalo M, Kaprio J, Kontula K. Survey of the coding region of the HERG gene in long QT syndrome reveals six novel mutations and an amino acid polymorphism with possible phenotypic effects. Hum Mutat 2000; 15:580-1. [PMID: 10862094 DOI: 10.1002/1098-1004(200006)15:6<580::aid-humu16>3.0.co;2-0] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Analysis of the entire coding region of the HERG gene of 39 Finnish LQTS patients revealed eight mutations, six of which are hitherto unreported. All these mutations are located in the evolutionarily conserved regions of HERG, including the transmembrane domains (P451L, Y569H, 1631delAG, G584S, G601S, T613M) and the cytoplasmic N-terminus (453delC, R176W) of the channel. Our present and earlier results suggest that the LQT2 subtype accounts for approximately 20-30% of LQTS cases in Finland. We also report the first common amino acid polymorphism (K897T) of the HERG channel, with allele frequencies of 0.84 and 0.16. Investigation of 170 genetically homogenous LQT1 patients suggests that this polymorphism may influence QT interval in female individuals.
Collapse
|
54
|
Toivonen L, Viitasalo M, Sundberg S, Akkila J, Lehtonen L. Electrophysiologic effects of a calcium sensitizer inotrope levosimendan administered intravenously in patients with normal cardiac function. J Cardiovasc Pharmacol 2000; 35:664-9. [PMID: 10774799 DOI: 10.1097/00005344-200004000-00021] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Provocation of fatal cardiac arrhythmias has limited the use of inotropic agents as heart failure therapy. Calcium sensitization of the myofilaments might increase inotropy without influencing cardiac electrophysiology unless modified by ancillary properties of the drugs. Electrophysiologic effects of a calcium sensitizer inotrope levosimendan were examined in short-term intravenous administration in humans. Variables were determined in 10 patients with normal cardiac function during a preceding control phase and levosimendan infusion yielding a high therapeutic concentration of 110 (+/-22) microg/L. Levosimendan increased heart rate by 9 beats/min (p < 0.01) on average and shortened the sinus node recovery time and AH interval. At the tested cycle lengths, levosimendan shortened the effective refractory periods in the atrioventricular node by 40-63 ms (p < 0.05), in the atrium by 22-33 ms (p < 0.001), and in the ventricle by 5-9 ms (p < 0.005) on average. Levosimendan increased ventricular monophasic action potential duration by 9-17 ms at 50% (p < 0.001) and by 5-15 ms (p = 0.07) at 90% levels of repolarization on average. The QT interval during spontaneous rhythm and atrial pacing remained unchanged although increased slightly when corrected to sinus rate (p < 0.001). The observations indicate that levosimendan in short-term administration facilitates impulse formation and conduction in cardiac slow-response tissue, enhances recovery of excitability in the myocardium, and may delay ventricular repolarization. The effects on the ventricle were not substantial, and therefore the likelihood of provoking serious cardiac arrhythmias is not estimated to be high.
Collapse
|
55
|
Korhonen P, Montonen J, Mäkijärvi M, Katila T, Nieminen MS, Toivonen L. Late fields of the magnetocardiographic QRS complex as indicators of propensity to sustained ventricular tachycardia after myocardial infarction. J Cardiovasc Electrophysiol 2000; 11:413-20. [PMID: 10809494 DOI: 10.1111/j.1540-8167.2000.tb00336.x] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
INTRODUCTION Magnetocardiographic (MCG) mapping is a new method to record cardiac signals. This study examined the association of MCG late fields with the propensity to sustained ventricular tachycardia (VT) after myocardial infarction (MI). METHODS AND RESULTS One hundred patients with remote MI were studied, 38 with and 62 without history of VT. High-resolution MCG and signal-averaged ECG (SAECG) as a comparative method were recorded. Time-domain parameters describing the abnormal low-amplitude end QRS activity, MCG late fields, and SAECG late potentials were analyzed. Late field parameters differed significantly between the patient groups: filtered QRS duration was 137 +/- 26 msec in the VT group and 110 +/- 18 msec in the control group (P < 0.001), and root mean square amplitude of the last 40 msec was 260 +/- 170 and 510 +/- 360 fT (P < 0.001), respectively. The optimal MCG parameter combination yielded a sensitivity of 92% and a specificity of 61% in classification to the VT group, whereas those for SAECG were 63% and 66%. In a subgroup of 63 patients with marked left ventricular dysfunction and comparable stage of coronary heart disease, only MCG (sensitivity 73%, specificity 67%) but not SAECG could assign a patient to the VT group. CONCLUSION Late fields of the MCG QRS complex indicate propensity to life-threatening arrhythmias in post-MI patients. This discriminative ability persists in the presence of severe left ventricular dysfunction where ECG late potentials lose their informative value. MCG late field analysis is a potential new method for noninvasive risk assessment in post-MI patients.
Collapse
|
56
|
Bäcklund M, Lepäntalo M, Toivonen L, Tuominen M, Tarkkil P, Pere P, Scheinin M, Lindgren L. Factors associated with post-operative myocardial ischaemia in elderly patients undergoing major non-cardiac surgery. Eur J Anaesthesiol 1999; 16:826-33. [PMID: 10747211 DOI: 10.1046/j.1365-2346.1999.00593.x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Forty patients (> 65 years) undergoing hip arthroplasty or peripheral vascular surgery both associated with high risk for post-operative myocardial ischaemia were randomized to receive either spinal or general anaesthesia. Ambulatory ECG recording (Holter) until the third post-operative morning, a daily 12-lead ECG and serum creatine kinase and troponine concentraItions were obtained. The number of ischaemic episodes, total duration of ischaemia and ischaemic minutes per hour were noted for each patient peri-operatively. Sixteen of the patients (40%) had post-operative myocardial ischaemia. An intra-operative increase in the plasma concentration of norepinephrine but not epinephrine was detected in the patients who later developed post-operative myocardial ischaemia. The increase in plasma norepinIephrine concentrations correlated with the decrease in core temperature. The type of anaesthesia had no effect on the incidence of myocardial ischaemia during or after surgery. Our results suggests that intra-operatively decreased core temperature and the increase in plasma concentration of norepinephrine probably caused peripheral vasoconstriction leading to latent cardiac dysfunction. These events should be avoided in the patients at risk of post-operative cardiac ischaemia.
Collapse
|
57
|
Swan H, Piippo K, Viitasalo M, Heikkilä P, Paavonen T, Kainulainen K, Kere J, Keto P, Kontula K, Toivonen L. Arrhythmic disorder mapped to chromosome 1q42-q43 causes malignant polymorphic ventricular tachycardia in structurally normal hearts. J Am Coll Cardiol 1999; 34:2035-42. [PMID: 10588221 DOI: 10.1016/s0735-1097(99)00461-1] [Citation(s) in RCA: 258] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES The purpose of this study was to provide clinical and anatomical characteristics as well as genetic background of a malignant arrhythmogenic disorder. BACKGROUND An inherited autosomally dominant cardiac syndrome causing stress-induced polymorphic ventricular tachycardia and syncope in the absence of structural myocardial changes was detected in two families. METHODS Two unrelated families with six victims of sudden death and 51 living members were evaluated. Resting and exercise electrocardiograms (ECG), echocardiography, magnetic resonance imaging (MRI), cineangiography, microscopic examination of endomyocardial biopsies and a drug testing with a class IC antiarrhythmic agent flecainide were performed. A genetic linkage analysis was carried out to map the gene locus. RESULTS Of the 24 affected individuals, 10 had succumbed with six cases of sudden death, and 14 survivors showed evidence of disease. Exercise stress test induced ventricular bigeminy or polymorphic ventricular tachycardia in affected individuals. Three children initially examined before 10 years of age developed arrhythmias during a four-year follow-up. Resting ECGs were normal in affected subjects except a slight prolongation of the QT intervals adjusted for heart rate (QTc) (430 +/- 18 vs. 409 +/- 19 ms, affected vs. nonaffected, p < 0.01). Administration of flecainide did not induce ECG abnormalities encountered in familial idiopathic ventricular fibrillation. Ventricular volumes, contractility and wall measurements were normal by echocardiography, right ventricular cineangiography and MRI. Histopathological examination showed no fibrosis or fatty infiltration. The cumulative cardiac mortality by the age of 30 years was 31%. The disease locus was assigned to chromosome 1q42-q43, with a maximal pairwise lod score of 4.74 in the two families combined. Only one heterozygous carrier was clinically unaffected suggesting high disease penetrance in adulthood. CONCLUSIONS A distinct cardiac disorder linked to chromosome 1q42-q43 causes exercise-induced polymorphic ventricular tachycardia in structurally normal hearts and is highly malignant. Delayed clinical manifestation necessitates repeated exercise electrocardiography to assure diagnosis in young individuals of the families.
Collapse
|
58
|
Westheim AS, Bostrøm P, Christensen CC, Parikka H, Rykke EO, Toivonen L. Hemodynamic and neuroendocrine effects for candoxatril and frusemide in mild stable chronic heart failure. J Am Coll Cardiol 1999; 34:1794-801. [PMID: 10577572 DOI: 10.1016/s0735-1097(99)00435-0] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
OBJECTIVES The study aimed to assess the hemodynamic and neuroendocrine effects of candoxatril and frusemide compared with placebo in patients with mild chronic heart failure. BACKGROUND Candoxatril is an atriopeptidase inhibitor. It increases circulating levels of atrial natriuretic peptide leading to natriuresis and diuresis, which alleviate the symptoms of a failing heart. METHODS This was a multicenter, randomized, double-blind study. Forty-seven patients with mild stable chronic heart failure received candoxatril 400 mg/day, frusemide 40 mg/day or placebo for up to six weeks. Cardiac indices were determined at rest and during exercise, and blood samples were taken for laboratory analysis. Assessments were performed at baseline (day 0) and after six weeks (day 42). RESULTS In comparison with placebo, both drugs significantly reduced mean pulmonary capillary wedge pressure following the first dose administration. Only candoxatril significantly reduced pulmonary capillary wedge pressure during exercise on day 0, while both drugs significantly reduced this parameter on day 42. Changes in the remaining hemodynamic parameters were comparable for both drugs relative to placebo. Frusemide significantly increased mean plasma renin activity (days 0 and 42), and the mean aldosterone concentration (day 42) in comparison with placebo, whereas candoxatril caused no significant changes in any of the hormonal parameters assessed. CONCLUSIONS These results show that candoxatril, 400 mg/day, has a similar hemodynamic profile to frusemide, 40 mg/day, but it does not induce adverse neuroendocrine effects. Candoxatril therefore appears to offer a clinically significant advantage over frusemide, providing an alternative therapeutic approach to the treatment of patients with mild stable chronic heart failure.
Collapse
|
59
|
Pesola K, Nenonen J, Fenici R, Lötjönen J, Mäkijärvi M, Fenici P, Korhonen P, Lauerma K, Valkonen M, Toivonen L, Katila T. Bioelectromagnetic localization of a pacing catheter in the heart. Phys Med Biol 1999; 44:2565-78. [PMID: 10533929 DOI: 10.1088/0031-9155/44/10/314] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The accuracy of localizing source currents within the human heart by non-invasive magneto- and electrocardiographic methods was investigated in 10 patients. A non-magnetic stimulation catheter inside the heart served as a reference current source. Biplane fluoroscopic imaging with lead ball markers was used to record the catheter position. Simultaneous multichannel magnetocardiographic (MCG) and body surface potential mapping (BSPM) recordings were performed during catheter pacing. Equivalent current dipole localizations were computed from MCG and BSPM data, employing standard and patient-specific boundary element torso models. Using individual models with the lungs included, the average MCG localization error was 7+/-3 mm, whereas the average BSPM localization error was 25+/-4 mm. In the simplified case of a single homogeneous standard torso model, an average error of 9+/-3 mm was obtained from MCG recordings. The MCG localization accuracies obtained in this study imply that the capability of multichannel MCG to locate dipolar sources is sufficient for clinical purposes, even without constructing individual torso models from x-ray or from magnetic resonance images.
Collapse
|
60
|
Swan H, Viitasalo M, Piippo K, Laitinen P, Kontula K, Toivonen L. Sinus node function and ventricular repolarization during exercise stress test in long QT syndrome patients with KvLQT1 and HERG potassium channel defects. J Am Coll Cardiol 1999; 34:823-9. [PMID: 10483966 DOI: 10.1016/s0735-1097(99)00255-7] [Citation(s) in RCA: 146] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
OBJECTIVES This study was performed to evaluate the QT interval and heart rate responses to exercise and recovery in gene and mutation type-specific subgroups of long QT syndrome (LQTS) patients. BACKGROUND Reduced heart rate and repolarization abnormalities are encountered among long QT syndrome (LQTS) patients. The most common types of LQTS are LQT1 and LQT2. METHODS An exercise stress test was performed in 23 patients with a pore region mutation and in 22 patients with a C-terminal end mutation of the cardiac potassium channel gene causing LQT1 type of long QT syndrome (KVLQT1 gene), as well as in 20 patients with mutations of the cardiac potassium channel gene causing LQT2 type of long QT syndrome (HERG gene) and in 33 healthy relatives. The QT intervals were measured on electrocardiograms at rest and during and after exercise. QT intervals were compared at similar heart rates, and rate adaptation of QT was studied as QT/heart rate slopes. RESULTS In contrast to the LQT2 patients, achieved maximum heart rate was decreased in both LQT1 patient groups, being only 76 +/- 5% of predicted in patients with pore region mutation of KvLQT1. The QT/heart rate slopes were significantly steeper in LQT2 patients than in controls during exercise. During recovery, the QT/heart rate slopes were steeper in all LQTS groups than in controls, signifying that QT intervals lengthened excessively when heart rate decreased. At heart rates of 110 or 100 beats/min during recovery, all LQT1 patients and 89% of LQT2 patients had QT intervals longer than any of the controls. CONCLUSIONS LQT1 is associated with diminished chronotropic response and exaggerated prolongation of QT interval after exercise. LQT2 patients differ from LQT1 patients by having marked QT interval shortening and normal heart rate response to exercise. Observing QT duration during recovery enhances the clinical diagnosis of these LQTS types.
Collapse
|
61
|
Bäcklund M, Toivonen L, Tuominen M, Pere P, Lindgren L. Changes in heart rate variability in elderly patients undergoing major noncardiac surgery under spinal or general anesthesia. Reg Anesth Pain Med 1999; 24:386-92. [PMID: 10499747 DOI: 10.1016/s1098-7339(99)90002-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
BACKGROUND AND OBJECTIVES Heart rate variability (HRV), widely used as an indicator of activity of the autonomic nervous system, has been reported to decrease during and after both spinal and general anesthesia in patients without cardiovascular disease. We evaluated the changes in HRV bands in 40 patients with a high risk of ischemic heart disease. METHODS The patients were randomly assigned to receive either spinal (SA) or general anesthesia (GA) for elective total hip arthroplasty or peripheral vascular surgery. Anesthetic techniques and perioperative fluid administration were standardized. Holter monitoring was started preoperatively and continued until the third postoperative day. Three HRV frequency bands were analyzed. RESULTS A significant decrease was seen in very low frequency (VLF) and low frequency (LF) bands during GA but not during SA. Also the LF/high frequency (HF) ratio decreased during GA but not during SA. A decrease in all HRV frequency bands was seen after both types of anesthesia. None of the frequency bands returned back to the preoperative level during the 3-day trial. Postoperatively circadian variation was found only in the VLF band after SA. CONCLUSIONS The sympathovagal balance (LF/HF) is more stable during SA than during GA in patients with a high risk of ischemic heart disease. The postoperative decrease in HRV bands, however, is independent of the anesthetic technique.
Collapse
|
62
|
Fenici R, Nenonen J, Pesola K, Korhonen P, Lötjönen J, Mäkijärvi M, Toivonen L, Poutanen VP, Keto P, Katila T. Nonfluoroscopic localization of an amagnetic stimulation catheter by multichannel magnetocardiography. Pacing Clin Electrophysiol 1999; 22:1210-20. [PMID: 10461298 DOI: 10.1111/j.1540-8159.1999.tb00602.x] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
This study was performed to: (1) evaluate the accuracy of noninvasive magnetocardiographic (MCG) localization of an amagnetic stimulation catheter; (2) validate the feasibility of this multipurpose catheter; and (3) study the characteristics of cardiac evoked fields. A stimulation catheter specially designed to produce no magnetic disturbances was inserted into the heart of five patients after routine electrophysiological studies. The catheter position was documented on biplane cine x-ray images. MCG signals were then recorded in a magnetically shielded room during cardiac pacing. Noninvasive localization of the catheter's tip and stimulated depolarization was computed from measured MCG data using a moving equivalent current-dipole source in patient-specific boundary element torso models. In all five patients, the MCG localizations were anatomically in good agreement with the catheter positions defined from the x-ray images. The mean distance between the position of the tip of the catheter defined from x-ray fluoroscopy and the MCG localization was 11 +/- 4 mm. The mean three-dimensional difference between the MCG localization at the peak stimulus and the MCG localization, during the ventricular evoked response about 3 ms later, was 4 +/- 1 mm calculated from signal-averaged data. The 95% confidence interval of beat-to-beat localization of the tip of the stimulation catheter from ten consecutive beats in the patients was 4 +/- 2 mm. The propagation velocity of the equivalent current dipole between 5 and 10 ms after the peak stimulus was 0.9 +/- 0.2 m/s. The results show that the use of the amagnetic catheter is technically feasible and reliable in clinical studies. The accurate three-dimensional localization of this multipurpose catheter by multichannel MCG suggests that the method could be developed toward a useful clinical tool during electrophysiological studies.
Collapse
|
63
|
Parikka H, Toivonen L, Naukkarinen V, Tierala I, Pohjola-Sintonen S, Heikkilä J, Nieminen MS. Decreases by magnesium of QT dispersion and ventricular arrhythmias in patients with acute myocardial infarction. Eur Heart J 1999; 20:111-20. [PMID: 10099907 DOI: 10.1053/euhj.1998.1238] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
AIMS Magnesium treatment suppresses ventricular arrhythmias in acute myocardial infarction and possibly mortality after infarction, but the underlying mechanisms are inadequately understood. We tested whether the effect of magnesium could be attributed to an influence on the autonomic control of the heart, changes in disturbed repolarization, relief of ischaemia or limitation of myocardial injury. METHODS AND RESULTS Fifty-nine consecutive patients with acute myocardial infarction were randomized to receive 70 mmol of magnesium (n = 31) infused over 24 h or placebo (n = 26). Occurrence of ventricular arrhythmias and heart rate variability (SD of 5-min mean sinus beat intervals over a 24 h period, SDANN; low frequency/high frequency amplitude ratio, LF/HF ratio), and the number of ischaemic episodes on vectorcardiography were measured from the first day of treatment. QT dispersion corrected for heart rate was measured from the 12-lead ECG. Magnesium decreased the number of hourly ventricular premature beats (P < 0.001) and the number of ventricular tachycardias (P < 0.05). QT dispersion corrected for heart rate was decreased in both measurements at 24 h and 1 week (P < 0.001). SDANN and LF/HF ratio were unchanged. The number of ischaemic episodes on vectorcardiography were equal, and peak creatine kinase MB release did not differ between the groups. In testing the pathophysiological mechanisms, serum magnesium levels after infusion correlated with hourly ventricular premature beats (rs = -0.47; P < 0.01), ventricular tachycardias (rs = -0.26; P < 0.05), and QT dispersion corrected for heart rate (rs = -0.75; P < 0.001), but not with SDANN, LF/HF ratio or peak creatine kinase MB. QT dispersion corrected for heart rate correlated with hourly ventricular premature beats (rs = 0.48; P < 0.001) and ventricular tachycardias (rs = 0.27; P < 0.05). CONCLUSIONS Magnesium suppresses early ventricular arrhythmias in acute myocardial infarction. The decreased arrhythmicity is related to enhancement of homogeneity in repolarization, but not to attenuation of prevailing ischaemia, improvement of autonomic nervous derangements or myocardial salvage.
Collapse
|
64
|
Pesola K, Hänninen H, Lauerma K, Lötjönen J, Mäkijärvi M, Nenonen J, Takala P, Voipio-Pulkki LM, Toivonen L, Katila T. Current density estimation on the left ventricular epicardium: A Potential method for ischemia localization. BIOMED ENG-BIOMED TE 1999. [DOI: 10.1515/bmte.1999.44.s2.143] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
65
|
Toivonen L. [Invasive treatment of cardiac arrhythmias]. DUODECIM; LAAKETIETEELLINEN AIKAKAUSKIRJA 1998; 111:2413-9. [PMID: 9841193] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
|
66
|
Toivonen L. [The modern treatment of cardiac arrhythmias]. DUODECIM; LAAKETIETEELLINEN AIKAKAUSKIRJA 1998; 111:2379-81. [PMID: 9841187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
|
67
|
Fenici R, Pesola K, Korhonen P, Mäkijärvi M, Nenonen J, Toivonen L, Fenici P, Katila T. Magnetocardiographic pacemapping for nonfluoroscopic localization of intracardiac electrophysiology catheters. Pacing Clin Electrophysiol 1998; 21:2492-9. [PMID: 9825373 DOI: 10.1111/j.1540-8159.1998.tb01207.x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
The purpose of the study was to validate, in patients, the accuracy of magnetocardiography (MCG) for three-dimensional localization of an amagnetic catheter (AC) for multiple monophasic action potential (MAP) with a spatial resolution of 4 mm2. The AC was inserted in five patients after routine electrophysiological study. Four MAPs were simultaneously recorded to monitor the stability of endocardial contact of the AC during the MCG localization. MAP signals were band-pass filtered DC-500 Hz and digitized at 2 KHz. The position of the AC was also imaged by biplane fluoroscopy (XR), along with lead markers. MCG studies were performed with a multichannel SQUID system in the Helsinki BioMag shielded room. Current dipoles (5 mm; 10 mA), activated at the tip of the AC, were localized using the equivalent current dipole (ECD) model in patient-specific boundary element torso. The accuracy of the MCG localizations was evaluated by: (1) anatomic location of ECD in the MRI, (2) mismatch with XR. The AC was correctly localized in the right ventricle of all patients using MRI. The mean three-dimensional mismatch between XR and MCG localizations was 6 +/- 2 mm (beat-to-beat analysis). The co efficient of variation of three-dimensional localization of the AC was 1.37% and the coefficient of reproducibility was 2.6 mm. In patients, in the absence of arrhythmias, average local variation coefficients of right ventricular MAP duration at 50% and 90% of repolarization, were 7.4% and 3.1%, respectively. This study demonstrates that with adequate signal-to-noise ratio, MCG three-dimensional localizations are accurate and reproducible enough to provide nonfluoroscopy dependant multimodal imaging for high resolution endocardial mapping of monophasic action potentials.
Collapse
|
68
|
Oikarinen L, Paavola M, Montonen J, Viitasalo M, Mäkijärvi M, Toivonen L, Katila T. Magnetocardiographic QT interval dispersion in postmyocardial infarction patients with sustained ventricular tachycardia: validation of automated QT measurements. Pacing Clin Electrophysiol 1998; 21:1934-42. [PMID: 9793090 DOI: 10.1111/j.1540-8159.1998.tb00013.x] [Citation(s) in RCA: 49] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
QT dispersion is a measure of heterogeneity in ventricular repolarization. Increased ECG QT dispersion is associated with life-threatening ventricular arrhythmias. We studied if magnetocardiographic (MCG) measures of QT dispersion can separate postmyocardial infarction patients with and without susceptibility to sustained VT. Manual dispersion measurements were compared to a newly adapted automatic QT interval analysis method. Ten patients with a history of sustained VT (VT group) and eight patients without ventricular arrhythmias (Controls) were studied after a remote myocardial infarction. Single-channel MCGs were recorded from 42 locations over the frontal chest area and the signals were averaged. QT dispersion was defined as maximum-minimum or standard deviation of measured QT intervals. VT group showed significantly more QT and JT dispersion than Controls. QTapex dispersions were 127 +/- 26 versus 83 +/- 21 ms (P = 0.004) and QTend dispersions 130 +/- 37 versus 82 +/- 37 ms (P = 0.013), respectively. Automatic method gave comparable values. Their relative differences were 9% for QTapex and 27% for QTend dispersion on average. In conclusion, increased MCG QT interval dispersion seems to be associated with a susceptibility to VT in postmyocardial infarction patients. MCG mapping with automated QT interval analysis may provide a user independent method to detect nonhomogeneity in ventricular repolarization.
Collapse
|
69
|
Sun ZH, Stjernvall J, Laine P, Toivonen L. Extensive variation in the signal amplitude of the atrial floating VDD pacing electrode. Pacing Clin Electrophysiol 1998; 21:1760-5. [PMID: 9744440 DOI: 10.1111/j.1540-8159.1998.tb00276.x] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
The dependence of atrial signal amplitude on the site of the atrial sensing dipole of a single-pass lead was examined in 29 patients. The vertical location of the dipole was documented in supine fluoroscopy during quiescent and deep breathing and in upright chest roentgenogram, and was expressed as a proportion of the right atrial height. As the group average, the atrial signal amplitude was equal when tested in supine, sitting, standing, and right- or left-side positions in follow-up determinations. The signal amplitude varied markedly between postures, showing a coefficient of variation of 45% +/- 24% within the group. Coefficient of variation within the 6-month follow-up period in each tested position ranged from 31%-44%. Correlation between postures was weak (range of r = 0.53-0.81). Vertical location of the atrial dipole had no relationship to the signal amplitude. At least in one posture or test occasion the atrial signal amplitude was very low, < or = 0.35 mV in 20 patients, and below detection limit (0.25 mV) in 5 patients. Programmed to high sensitivity, atrial undersensing was rare in ambulatory electrocardiography, ranging from 0-9,000 missed atrial beats (0%-8%), with a median of 100 beats/24 hours. In conclusion, temporary variation in atrial signal amplitude is extensive. Despite occasionally measured large signal amplitudes atrial sensitivity in single lead VDD pacemakers should be programmed high, and if poor atrial tracking is suspected, other methods besides routine sensitivity testing should be adapted.
Collapse
|
70
|
Swan H, Saarinen K, Kontula K, Toivonen L, Viitasalo M. Evaluation of QT interval duration and dispersion and proposed clinical criteria in diagnosis of long QT syndrome in patients with a genetically uniform type of LQT1. J Am Coll Cardiol 1998; 32:486-91. [PMID: 9708480 DOI: 10.1016/s0735-1097(98)00248-4] [Citation(s) in RCA: 50] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
OBJECTIVES This study investigated the ability of QT duration, QT dispersion (QTD) and clinical diagnostic criteria to correctly identify genetically documented LQT1 type long QT syndrome (LQTS) patients, and to separate symptomatic and asymptomatic LQT1 patients. BACKGROUND Ventricular repolarization has played an essential role both in diagnosis and risk assessment of LQTS. Today, molecular genetic techniques permit unequivocal identification of many LQTS patients. METHODS QT interval and QTD in 12 symptomatic and 18 asymptomatic LQT1 patients and their 43 healthy relatives were evaluated. The sensitivity and specificity of upper normal limits of QT interval, two QT interval adjustment methods (Bazett's and Fridericia's formulas), and the proposed clinical criteria for LQTS were assessed. Occurrence of a mutant (D188N) KVLQT1 gene was considered as the basis of classification into affected and nonaffected individuals. RESULTS Diagnostic sensitivity and specificity values were 90% and 88% using Bazett's formula, and 80% and 100% using Fridericia's cubic root formula or upper normal limits for QT interval. Suggested diagnostic criteria for LQTS reached 100% specificity, but 47% of the DNA-documented LQT1 patients were classified into the category of low or intermediate probability of LQTS. QT interval and heart rate did not differ between symptomatic (464 +/- 47 ms, 70 +/- 9 min(-1)) and asymptomatic 460 +/- 41 ms, 65 +/- 13 min(-1)) LQT1 patients. QTD was increased in symptomatic LQT1 patients compared to unaffected relatives (66 +/- 48 vs. 37 +/- 15 ms, p = 0.02), but symptomatic patients LQT1 did not differ from asymptomatic (45 +/- 19 ms). CONCLUSIONS Not all LQT1 patients can be distinguished from healthy relatives by assessment of QT duration or clinical criteria. Presence of LQT1 gene can carry the risk of cardiac events even with no or only marginal prolongation of QT interval.
Collapse
|
71
|
Mäki T, Toivonen L, Koskinen P, Näveri H, Härkönen M, Leinonen H. Effect of ethanol drinking, hangover, and exercise on adrenergic activity and heart rate variability in patients with a history of alcohol-induced atrial fibrillation. Am J Cardiol 1998; 82:317-22. [PMID: 9708660 DOI: 10.1016/s0002-9149(98)00299-9] [Citation(s) in RCA: 71] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
To elucidate the mechanism of alcohol-induced atrial fibrillation (AF) we studied the heart rate variability and parameters of the adrenergic system during alcohol intake, hangover, and exercise in 6 men (mean age 43 years) prone to alcohol-induced AF, together with 6 age-matched controls. The ambulatory (15 hour) electrocardiogram was recorded and blood samples were taken for lymphocytic beta adrenoceptor, plasma catecholamine, and cyclic adenosine monophosphate (cAMP) measurements before and after alcohol intake (blood alcohol 1.5 per thousand), during hangover, and after a standardized bicycle exercise test. The beta-adrenoceptor density in lymphocytes was unchanged in the control group after alcohol intake or during hangover. Each of the AF patients had an increase in beta-adrenoceptor density after ethanol drinking (mean increase 29%, p <0.05). The hangover or exercise beta-receptor values did not differ from those in corresponding controls. Plasma adrenaline concentration tended to decrease and noradrenaline to increase after drinking and during hangover in both groups. Plasma cAMP levels were lower in patients after drinking than in controls (p <0.05). The exercise values of the adrenergic parameters were very similar in AF patients whether or not preceded by alcohol. Analysis of ambulatory electrocardiography showed a very low rate of ectopic beats in both AF patients and controls. Analysis of heart rate variability revealed a tendency toward an increase in sympathetic/parasympathetic component ratio (low-frequency/high-frequency ratio) in AF patients, but not in controls, after ethanol drinking. In conclusion, no signs of arrhythmogenic cardiac disease were detected in patients with AF to explain the tendency toward AF. Increases in beta-adrenoceptor density and low-frequency/high-frequency ratio during ethanol intoxication in patients with AF suggest an exaggerated sympathetic reaction.
Collapse
|
72
|
Viitasalo M, Karjalainen J, Mäkijärvi M, Toivonen L. Autonomic modulation of QT intervals in post-myocardial infarction patients with and without ventricular fibrillation. Am J Cardiol 1998; 82:154-9. [PMID: 9678284 DOI: 10.1016/s0002-9149(98)00319-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
The autonomic nervous system plays an important role in the genesis of sudden cardiac death. The aim of this study was to evaluate spatial autonomic QT interval modulation at the myocardial level. Circadian patterns of QT intervals and heart rate variability (HRV) components and their hourly linear correlations were determined by Holter recordings in 15 healthy subjects (controls), in 15 post-myocardial infarction (MI) patients resuscitated from ventricular fibrillation (VF) (VF group), and in 15 matched infarction patients without a history of arrhythmia events (MI group). QT intervals were measured in modified leads V1 and V5 individually at same stable heart rates during each hour and related to hourly measures of HRV. Controls had highly significant correlations between QT intervals and the high-frequency component of HRV (parasympathetic modulation), and between QT intervals and low- to high-frequency ratio (sympathetic modulation) uniformly in both leads (r from 0.62 to 0.81, p <0.001). The MI group had impaired sympathetic modulation in V5 (r = 0.34, p = NS), but had uniform and exaggerated sensitivity to parasympathetic modulation. In the VF group the QT difference between V1 and V5 leads correlated with parasympathetic modulation (r = 0.401, p <0.05) and sympathetic modulation (r = 0.446, p <0.05). Thus, normal subjects exhibit spatially uniform autonomic QT modulation. Myocardial damage can result in abolished, exaggerated, or regionally discordant QT modulation, and this may generate arrhythmic vulnerability.
Collapse
|
73
|
Oikarinen L, Toivonen L, Viitasalo M. Electrocardiographic measures of ventricular repolarisation dispersion in patients with coronary artery disease susceptible to ventricular fibrillation. Heart 1998; 79:554-9. [PMID: 10078081 PMCID: PMC1728728 DOI: 10.1136/hrt.79.6.554] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/03/2022] Open
Abstract
OBJECTIVE To study electrocardiographic measures of ventricular repolarisation dispersion in patients prone to ventricular fibrillation compared with controls matched for the extent of coronary heart disease and the use of beta blockers. DESIGN A case-control study. SETTING Cardiovascular laboratory of a tertiary referral centre. PATIENTS Fifty patients with documented ventricular fibrillation not associated with acute myocardial infarction, and their controls matched for sex, age, number of diseased coronary vessels, left ventricular ejection fraction, previous myocardial infarction and its location, and the use of beta blockers. MAIN OUTCOME MEASURES Electrocardiographic measures of QT, JT, and Tend interval dispersions in a 12 lead electrocardiogram. RESULTS The ventricular fibrillation patients compared to controls showed increased mean (SD) QTapex dispersion (53 (18) ms v 44 (18) ms, respectively; p < 0.01) and mean (SD) Tend dispersion (46 (17) ms v 38 (15) ms, respectively; p < 0.05). CONCLUSIONS Increased QTapex and Tend dispersions are associated with a susceptibility to ventricular fibrillation even when the extent of the coronary heart disease and use of beta blockers are taken into consideration. However, because of a considerable overlap between the groups, measures of QT dispersion assessed from a 12 lead electrocardiogram do not provide clinically useful information for identification of patients at risk of sudden cardiac death.
Collapse
|
74
|
Sun ZH, Swan H, Viitasalo M, Toivonen L. Effects of epinephrine and phenylephrine on QT interval dispersion in congenital long QT syndrome. J Am Coll Cardiol 1998; 31:1400-5. [PMID: 9581741 DOI: 10.1016/s0735-1097(98)00104-1] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
OBJECTIVES Measurement of QT interval dispersion during pharmacologic adrenergic stimulation was used to assess the effect of alpha- and beta-adrenergic stimulation on arrhythmic vulnerability in familial long QT syndrome (LQTS). BACKGROUND Nonhomogeneity in the ventricular action potential duration causes electrical instability leading to life-threatening ventricular arrhythmias and is markedly increased in LQTS. QT interval dispersion measured from the electrocardiogram (ECG) can be used as an index of nonhomogeneous ventricular repolarization. METHODS Sixteen symptomatic patients with LQTS and nine healthy control subjects were examined at baseline and during epinephrine (mainly beta-adrenergic agonist, 0.05 microg/kg body weight per min) and phenylephrine infusions (alpha-adrenergic agonist, mean 1.4 microg/kg per min). QT interval dispersion was determined from a 12-lead ECG as interlead range and coefficient of variation measured to the end (QTend) and apex (QTapex) of the T wave. RESULTS At baseline QTend dispersion was greater in patients with LQTS compared with control subjects (mean [+/-SD] 68+/-34 vs. 36+/-7 ms, p=0.001). QTend dispersion was markedly increased in patients with LQTS by use of epinephrine (from 68+/-34 to 90+/-36 ms, p=0.002), but remained unchanged in control subjects. Phenylephrine did not affect QT dispersion in either group (all p=NS). Atrial pacing to achieve comparable heart rates during baseline and epinephrine and phenylephrine infusions did not influence the magnitude of QT dispersion in either group. QTapex dispersion analysis gave congruent results. CONCLUSIONS Epinephrine but not phenylephrine increased QT dispersion, suggesting that beta-adrenergic stimulation provokes arrhythmias in patients with LQTS by aggravating nonhomogeneity of ventricular repolarization, whereas alpha-adrenergic stimulation is less important for arrhythmic vulnerability. The results also suggest that rapid pacing may not reduce vulnerability to arrhythmias in congenital LQTS.
Collapse
|
75
|
Oikarinen L, Viitasalo M, Toivonen L. Dispersions of the QT interval in postmyocardial infarction patients presenting with ventricular tachycardia or with ventricular fibrillation. Am J Cardiol 1998; 81:694-7. [PMID: 9527076 DOI: 10.1016/s0002-9149(97)01002-3] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Increased QT interval dispersion is associated with ventricular arrhythmias. The aim of this study was to examine if in postmyocardial infarction patients with impaired left ventricular function, increased QT dispersion is associated with ventricular tachycardia (VT) and ventricular fibrillation (VF). Measures of QT dispersion, calculated as maximum-minimum (D) and standard deviation (SD) of QTend, QTapex, JTend, JTapex, and Tend intervals in the 12-lead electrocardiogram, were compared in patients who late after myocardial infarction experienced sustained VT (VT group) only, VF (VF group) only, or had no ventricular arrhythmias (controls). The 25 patients in each group were individually matched for age, gender, number of diseased coronary vessels, location of the previous myocardial infarction, and left ventricular ejection fraction. Dispersion measures of QTend, QTapex, and JTapex intervals separated VT group from controls, but none of the measures separated the VF group from controls. QTendD was 49+/-18 ms in controls, 57+/-18 ms in the VF group (controls vs VF group, p = NS), and 65+/-29 ms in the VT group (controls vs VT group, p <0.05). VT group had increased QTapexSD, JTapexSD, and JTapexD compared with the VF group. The cycle length of induced sustained monomorphic VT, present in 19 VT and 19 VF patients, correlated with several dispersion indexes in the VT group, but not with those in the VF group. Thus, in postmyocardial infarction patients with a severely damaged left ventricle, increased QT dispersion is associated with susceptibility to sustained VT, but not to VF.
Collapse
|