51
|
Shibasaki S, Takamizawa T, Suzuki T, Nojiri K, Tsujimoto A, Barkmeier WW, Latta MA, Miyazaki M. Influence of Different Curing Modes on Polymerization Behavior and Mechanical Properties of Dual-Cured Provisional Resins. Oper Dent 2017; 42:526-536. [PMID: 28605612 DOI: 10.2341/16-335-l] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This study determined the influence of curing mode on polymerization behavior and mechanical properties of dual-cured provisional resins. Three dual-cured bisacryl-based provisional resins were used: Tempsmart (TS; GC Corp), Luxatemp Automix Solar (LX; DMG Chemisch Pharmazeutishe Fabrik GmbH), and Integrity Multi·Cure (IG; Dentsply Caulk). A self-cured bisacryl-based provisional resin, Protemp Plus (PP; 3M ESPE) and a conventional poly(methyl methacrylate) (PMMA) provisional resin, Unifast III (UF; GC Corp) were used as controls. The inorganic filler content and coefficients of linear thermal expansion of the test materials were measured. Six specimens of each material were used to determine the flexural strength, elastic modulus, and resilience. The changes in ultrasound velocity during polymerization were measured. The average inorganic filler contents of the provisional resins, apart from UF, ranged from 24.4 to 39.3 wt%. The highest inorganic filler content was determined for LX, whereas TS showed the lowest value among the tested materials. The average coefficients of thermal expansion of the tested provisional resins ranged from 77.3 to 107.7 (×10-6/°C). TS and IG showed significantly lower thermal expansions than the other tested provisional resins. The mean flexural strengths of the provisional resins ranged from 70.4 to 122.6 MPa, the mean elastic moduli ranged from 1.8 to 3.7 GPa, and the mean resilience of the provisional resins ranged from 1.1 to 2.3 MJ/mm3, respectively. Dual-cured provisional resins showed significantly higher flexural strengths than the PMMA resin. However, in all cases, the light-curing mode showed significantly higher flexural strengths than the self-curing mode. In the initial polymerization phase, dual-cured resins in the light-curing mode showed a rapid increase in the speed of sound (V) during light irradiation, followed by a slower increase. Conversely, the dual-cured resins in the self-curing mode showed a slower initial increase, followed by a rapid increase. Although no significant difference in V was observed between 10 and 15 minutes in the light-curing mode of all tested dual-cured resins, a significantly higher V value was obtained at 15 minutes than at 10 minutes in the self-curing modes for LX and IG. Regardless of the curing mode, tested dual-cured provisional resins showed superior mechanical properties than the conventional PMMA provisional resin. However, dual-cured provisional resin flexural properties and polymerization behavior were affected by the curing mode. This study indicated that the light-curing mode might be recommended for all dual-cured provisional resins because of the enhancement of their mechanical properties and reduction of chair time.
Collapse
|
52
|
Miyazaki T, Okada K, Yamashita T, Miyazaki M. Two-dimensional gas chromatography time-of-flight mass spectrometry-based serum metabolic fingerprints of neonatal calves before and after first colostrum ingestion. J Dairy Sci 2017; 100:4354-4364. [DOI: 10.3168/jds.2017-12557] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2017] [Accepted: 01/29/2017] [Indexed: 12/26/2022]
|
53
|
Tsujimoto A, Barkmeier WW, Takamizawa T, Wilwerding TM, Latta MA, Miyazaki M. Interfacial Characteristics and Bond Durability of Universal Adhesive to Various Substrates. Oper Dent 2017; 42:E59-E70. [DOI: 10.2341/15-353-l] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
Objective: This study investigated the interfacial characteristics and bond durability of universal adhesives to various substrates.
Methods and Materials: Two universal adhesives were used: 1) Scotchbond Universal and 2) G-Premio Bond. The substrates used were bovine enamel and dentin with or without phosphoric acid etching, resin composite, lithium disilicate and leucite-reinforced glass ceramics, zirconia, and metal alloys. The surface free energy and the parameters of various substrates and of substrates treated by adhesive after light irradiation were determined by measuring the contact angles of three test liquids. Resin composite was bonded to the various substrates to determine shear bond strength after 24 hours water storage and 10,000 thermal cycles. A one-way analysis of variance (ANOVA) and the Tukey post hoc test were used for the surface free energy data, and a two-way ANOVA and the Tukey post hoc test were used for analysis of shear bond strength data (α=0.05).
Results: The interfacial characteristics of the various substrates show significant differences depending on the type of substrate, but the interfacial characteristics of substrate treated by adhesive after light irradiation did not show any significant differences regardless of the substrate used. The bond durability of two universal adhesives to various substrates differs depending on the type of substrate and the adhesive.
Conclusions: The results of this study suggest that universal adhesives modify the interfacial characteristics of a wide range of substrates and create a consistent surface, but the bond durability of universal adhesive to various substrates differs depending on the type of substrate and the adhesive.
Collapse
|
54
|
Kanayama N, Kierkels R, Steenbakkers R, Van der Schaaf A, Miyazaki M, Fujii T, Nishiyama K, Langendijk J, Teshima T. PO-064: Normal tissue complication probability model for tube feeding dependence 6 months after radiotherapy. Radiother Oncol 2017. [DOI: 10.1016/s0167-8140(17)30198-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
55
|
Miyazaki M. Four and a half years of experience of a clinician born and raised in Fukushima: discrepancy found through dialogues and practices. Ann ICRP 2016; 45:23-32. [PMID: 28054490 DOI: 10.1177/0146645316680576] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Many initiatives to measure the internal and external exposures of the residents of Fukushima have been undertaken since the accident at Fukushima Daiichi nuclear power plant. However, residents have had few, if any, opportunities for face-to-face explanations to understand the meaning of such measurements. Although the personal data of tens of thousands of residents were collected, these data were not analysed adequately, and were therefore not used to implement large-scale programmes to manage/reduce exposures. One of the lessons learned from the Fukushima accident is that it is imperative for the government to implement these measures for radiation protection, and to build an effective functioning service for the residents. The author, as a physician from the region, has worked as an explainer/interpreter of exposure dose measurements to individual residents. Another lesson learned from this experience is that local medical and health professionals can contribute to building a public system for radiation protection, by acting as 'liaising officers' to connect residents, the authorities, and experts from outside the region. This paper describes the author's experience and lessons learned in the hope that this information will be useful in the event of a future accident.
Collapse
|
56
|
Tsujimoto A, Barkmeier WW, Takamizawa T, Latta MA, Miyazaki M. Influence of Thermal Cycling on Flexural Properties and Simulated Wear of Computer-aided Design/Computer-aided Manufacturing Resin Composites. Oper Dent 2016; 42:101-110. [PMID: 27802120 DOI: 10.2341/16-046-l] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVE The purpose of this study was to evaluate the influence of thermal cycling on the flexural properties and simulated wear of computer-aided design/computer-aided manufacturing (CAD/CAM) resin composites. METHODS The six CAD/CAM resin composites used in this study were 1) Lava Ultimate CAD/CAM Restorative (LU); 2) Paradigm MZ100 (PM); 3) CERASMART (CS); 4) Shofu Block HC (SB); 5) KATANA AVENCIA Block (KA); and 6) VITA ENAMIC (VE). Specimens were divided randomly into two groups, one of which was stored in distilled water for 24 hours, and the other of which was subjected to 10,000 thermal cycles. For each material, 15 specimens from each group were used to determine the flexural strength and modulus according to ISO 6872, and 20 specimens from each group were used to examine wear using a localized wear simulation model. The test materials were subjected to a wear challenge of 400,000 cycles in a Leinfelder-Suzuki device (Alabama machine). The materials were placed in custom-cylinder stainless steel fixtures, and simulated localized wear was generated using a stainless steel ball bearing (r=2.387 mm) antagonist in a water slurry of polymethyl methacrylate beads. Simulated wear was determined using a noncontact profilometer (Proscan 2100) with Proscan and AnSur 3D software. RESULTS The two-way analysis of variance of flexural properties and simulated wear of CAD/CAM resin composites revealed that material type and thermal cycling had a significant influence (p<0.05), but there was no significant interaction (p>0.05) between the two factors. The flexural properties and maximum depth of wear facets of CAD/CAM resin composite were different (p<0.05) depending on the material, and their values were influenced (p>0.05) by thermal cycling, except in the case of VE. The volume losses in wear facets on LU, PM, and SB after 10,000 thermal cycles were significantly higher (p<0.05) than those after 24 hours of water storage, unlike CS, KA, and VE. CONCLUSION The results of this study indicate that the flexural properties and simulated wear of CAD/CAM resin composites are different depending on the material. In addition, the flexural properties and simulated wear of CAD/CAM resin composites are influenced by thermal cycling.
Collapse
|
57
|
Tsujii K, Ueda Y, Isono M, Miyazaki M, Teshima T. Dosimetric Impact of Rotational Setup Errors for Cervical Cancer Patients With Postoperative Volumetric Modulated Arc Therapy. Int J Radiat Oncol Biol Phys 2016. [DOI: 10.1016/j.ijrobp.2016.06.2141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
58
|
Suzuki D, Furukawa K, Furukawa A, Shimizu H, Otsuka M, Kato A, Yoshitomi H, Takayashiki T, Kuboki S, Takano S, Sakai N, Kagawa S, Nojima H, Miyazaki M. SUN-P144: Does the Modified Glasgow Prognostic Score have a Prognostic Role in Gallbladder Cancer? Clin Nutr 2016. [DOI: 10.1016/s0261-5614(16)30487-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
59
|
Furukawa A, Furukawa K, Suzuki D, Shimizu H, Ohtsuka M, Kato A, Yoshitomi H, Takayashiki T, Kuboki S, Takano S, Sakai N, Kagawa S, Nojima H, Miyazaki M. MON-P233: Impact of Immunonutrition on Infectious Complications in Sarcopenic Patients Undergoing Pancreaticoduodenectomy. Clin Nutr 2016. [DOI: 10.1016/s0261-5614(16)30867-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
60
|
Furukawa K, Furukawa A, Suzuki D, Shimizu H, Ohtsuka M, Kato A, Yoshitomi H, Takayashiki T, Kuboki S, Takano S, Sakai N, Kagawa S, Nojima H, Miyazaki M. MON-P236: Influence Of Sarcopenia On Infectious Complications in Patients Undergoing Pancreaticoduodenectomy. Clin Nutr 2016. [DOI: 10.1016/s0261-5614(16)30870-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
61
|
Nakahama H, Okada M, Miyazaki M, Imai N, Yokokawa T, Kubori S. Distinct Responses of Interleukin-6 and Other Laboratory Parameters to Treatment in a Patient with Polyarteritis Nodosa—A Case Report. Angiology 2016; 43:512-6. [PMID: 1350713 DOI: 10.1177/000331979204300610] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
The authors describe a patient in whom the serum levels of interleukin-6 (IL-6) and other laboratory parameters were monitored. The IL-6 and C-reac tive protein (CRP) levels, which were extremely high before treatment, declined rapidly with administration of prednisolone. Rheumatoid factor, IgG, and platelets count declined more gradually. Thus, determination of the serum IL-6 level might be useful in diagnosing and monitoring polyarteritis nodosa.
Collapse
|
62
|
Suzuki T, Takamizawa T, Barkmeier WW, Tsujimoto A, Endo H, Erickson RL, Latta MA, Miyazaki M. Influence of Etching Mode on Enamel Bond Durability of Universal Adhesive Systems. Oper Dent 2016; 41:520-530. [PMID: 27351078 DOI: 10.2341/15-347-l] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The purpose of this study was to determine the enamel bond durability of three universal adhesives in different etching modes through fatigue testing. The three universal adhesives used were Scotchbond Universal, Prime&Bond Elect universal dental adhesive, and All-Bond Universal light-cured dental adhesive. A single-step self-etch adhesive, Clearfil S3 Bond Plus was used as a control. The shear bond strength (SBS) and shear fatigue strength (SFS) to human enamel were evaluated in total-etch mode and self-etch mode. A stainless steel metal ring with an internal diameter of 2.4 mm was used to bond the resin composite to the flat-ground (4000-grit) tooth surfaces for determination of both SBS and SFS. For each enamel surface treatment, 15 specimens were prepared for SBS and 30 specimens for SFS. The staircase method for fatigue testing was then used to determine the SFS of the resin composite bonded to the enamel using 10-Hz frequencies for 50,000 cycles or until failure occurred. Scanning electron microscopy was used to observe representative debonded specimen surfaces and the resin-enamel interfaces. A two-way analysis of variance and the Tukey post hoc test were used for analysis of the SBS data, whereas a modified t-test with Bonferroni correction was used for the SFS data. All adhesives in total-etch mode showed significantly higher SBS and SFS values than those in self-etch mode. Although All-Bond Universal in self-etch mode showed a significantly lower SBS value than the other adhesives, there was no significant difference in SFS values among the adhesives in this mode. All adhesives showed higher SFS:SBS ratios in total-etch mode than in self-etch mode. With regard to the adhesive systems used in this study, universal adhesives showed higher enamel bond strengths in total-etch mode. Although the influence of different etching modes on the enamel-bonding performance of universal adhesives was found to be dependent on the adhesive material, total-etch mode effectively increased the enamel bond strength and durability, as measured by fatigue testing.
Collapse
|
63
|
Miyachi S, Ishiguchi T, Taniguchi K, Miyazaki M, Maeda K. Endovascular Stenting for Pseudoaneurysms of the Cervical Carotid Artery. Interv Neuroradiol 2016; 3 Suppl 2:129-32. [DOI: 10.1177/15910199970030s227] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/1997] [Accepted: 09/18/1997] [Indexed: 11/17/2022] Open
Abstract
The authors report two cases of pseudoaneurysm of the cervical carotid artery treated with endovascular stenting. One patient presented with cerebral ischemia due to traumatic carotid dissection and underwent stent placement 3 weeks after injury when the wide-necked pseudoaneurysm was seen to enlarge at the dissecting portion. The aneurysm thrombosed while the carotid artery remained patent without ischemic complications for 2 years. The other patient developed repeated massive bleeding from an exposed pseudoaneurysm at the right carotid-subclavian junction resulting from radiotherapy for thyroid cancer with subsequent skin infection. Since skin grafting failed and two attempts at coil embolization resulted in compaction with recurrent enlargement of the aneurysm, endovascular stenting was performed with endosaccular coil packing between the stent struts. Hemostasis was achieved for 2 months. Both cases illustrate successes of the stent in highly difficult situations.
Collapse
|
64
|
Furuichi T, Takamizawa T, Tsujimoto A, Miyazaki M, Barkmeier WW, Latta MA. Mechanical Properties and Sliding-impact Wear Resistance of Self-adhesive Resin Cements. Oper Dent 2016; 41:E83-92. [DOI: 10.2341/15-033-l] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
The present study determined the mechanical properties and impact-sliding wear characteristics of self-adhesive resin cements. Five self-adhesive resin cements were used: G-CEM LinkAce, BeautiCem SA, Maxcem Elite, Clearfil SA Automix, and RelyX Unicem 2. Clearfil Esthetic Cement was employed as a control material. Six specimens for each resin cement were used to determine flexural strength, elastic modulus, and resilience according to ISO specification #4049. Ten specimens for each resin cement were used to determine the wear characteristics using an impact-sliding wear testing apparatus. Wear was generated using a stainless-steel ball bearing mounted inside a collet assembly. The maximum facet depth and volume loss were determined using a noncontact profilometer in combination with confocal laser scanning microscopy. Data were evaluated using analysis of variance followed by the Tukey honestly significantly different test (α=0.05). The flexural strength of the resin cements ranged from 68.4 to 144.2 MPa; the elastic modulus ranged from 4.4 to 10.6 GPa; and the resilience ranged from 4.5 to 12.0 MJ/m3. The results for the maximum facet depth ranged from 25.2 to 235.9 μm, and volume loss ranged from 0.0107 to 0.5258 mm3. The flexural properties and wear resistance were found to vary depending upon the self-adhesive resin cement tested. The self-adhesive cements tended to have lower mechanical properties than the conventional resin cement. All self-adhesive resin cements, apart from G-CEM LinkAce, demonstrated significantly poorer wear resistance than did the conventional resin cement.
Collapse
|
65
|
Oyama K, Arai T, Isaka A, Sekiguchi T, Itoh H, Seto Y, Miyazaki M, Itabashi T, Ohki T, Suzuki M, Ishiwata S. Directional bleb formation in spherical cells under temperature gradient. Biophys J 2016. [PMID: 26200871 DOI: 10.1016/j.bpj.2015.06.016] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Living cells sense absolute temperature and temporal changes in temperature using biological thermosensors such as ion channels. Here, we reveal, to our knowledge, a novel mechanism of sensing spatial temperature gradients within single cells. Spherical mitotic cells form directional membrane extensions (polar blebs) under sharp temperature gradients (≥∼0.065°C μm(-1); 1.3°C temperature difference within a cell), which are created by local heating with a focused 1455-nm laser beam under an optical microscope. On the other hand, multiple nondirectional blebs are formed under gradual temperature gradients or uniform heating. During heating, the distribution of actomyosin complexes becomes inhomogeneous due to a break in the symmetry of its contractile force, highlighting the role of the actomyosin complex as a sensor of local temperature gradients.
Collapse
|
66
|
Tsujimoto A, Barkmeier WW, Takamizawa T, Latta MA, Miyazaki M. The Effect of Phosphoric Acid Pre-etching Times on Bonding Performance and Surface Free Energy with Single-step Self-etch Adhesives. Oper Dent 2016; 41:441-9. [PMID: 27054410 DOI: 10.2341/15-221-l] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVE The purpose of this study was to evaluate the effect of phosphoric acid pre-etching times on shear bond strength (SBS) and surface free energy (SFE) with single-step self-etch adhesives. METHODS The three single-step self-etch adhesives used were: 1) Scotchbond Universal Adhesive (3M ESPE), 2) Clearfil tri-S Bond (Kuraray Noritake Dental), and 3) G-Bond Plus (GC). Two no pre-etching groups, 1) untreated enamel and 2) enamel surfaces after ultrasonic cleaning with distilled water for 30 seconds to remove the smear layer, were prepared. There were four pre-etching groups: 1) enamel surfaces were pre-etched with phosphoric acid (Etchant, 3M ESPE) for 3 seconds, 2) enamel surfaces were pre-etched for 5 seconds, 3) enamel surfaces were pre-etched for 10 seconds, and 4) enamel surfaces were pre-etched for 15 seconds. Resin composite was bonded to the treated enamel surface to determine SBS. The SFEs of treated enamel surfaces were determined by measuring the contact angles of three test liquids. Scanning electron microscopy was used to examine the enamel surfaces and enamel-adhesive interface. RESULTS The specimens with phosphoric acid pre-etching showed significantly higher SBS and SFEs than the specimens without phosphoric acid pre-etching regardless of the adhesive system used. SBS and SFEs did not increase for phosphoric acid pre-etching times over 3 seconds. There were no significant differences in SBS and SFEs between the specimens with and without a smear layer. CONCLUSION The data suggest that phosphoric acid pre-etching of ground enamel improves the bonding performance of single-step self-etch adhesives, but these bonding properties do not increase for phosphoric acid pre-etching times over 3 seconds.
Collapse
|
67
|
Miyazaki M, Ueda Y, Ohira S, Tsujii K, Isono M, Masaoka A, Teshima T. OC-0269: Comparison of dosimetric parameters of two techniques with VMAT for head and neck cancers. Radiother Oncol 2016. [DOI: 10.1016/s0167-8140(16)31518-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
68
|
Adachi N, Adamovitch V, Adjovi Y, Aida K, Akamatsu H, Akiyama S, Akli A, Ando A, Andrault T, Antonietti H, Anzai S, Arkoun G, Avenoso C, Ayrault D, Banasiewicz M, Banaśkiewicz M, Bernardini L, Bernard E, Berthet E, Blanchard M, Boreyko D, Boros K, Charron S, Cornette P, Czerkas K, Dameron M, Date I, De Pontbriand M, Demangeau F, Dobaczewski Ł, Dobrzyński L, Ducouret A, Dziedzic M, Ecalle A, Edon V, Endo K, Endo T, Endo Y, Etryk D, Fabiszewska M, Fang S, Fauchier D, Felici F, Fujiwara Y, Gardais C, Gaul W, Gurin L, Hakoda R, Hamamatsu I, Handa K, Haneda H, Hara T, Hashimoto M, Hashimoto T, Hashimoto K, Hata D, Hattori M, Hayano R, Hayashi R, Higasi H, Hiruta M, Honda A, Horikawa Y, Horiuchi H, Hozumi Y, Ide M, Ihara S, Ikoma T, Inohara Y, Itazu M, Ito A, Janvrin J, Jout I, Kanda H, Kanemori G, Kanno M, Kanomata N, Kato T, Kato S, Katsu J, Kawasaki Y, Kikuchi K, Kilian P, Kimura N, Kiya M, Klepuszewski M, Kluchnikov E, Kodama Y, Kokubun R, Konishi F, Konno A, Kontsevoy V, Koori A, Koutaka A, Kowol A, Koyama Y, Kozioł M, Kozue M, Kravtchenko O, Kruczała W, Kudła M, Kudo H, Kumagai R, Kurogome K, Kurosu A, Kuse M, Lacombe A, Lefaillet E, Magara M, Malinowska J, Malinowski M, Maroselli V, Masui Y, Matsukawa K, Matsuya K, Matusik B, Maulny M, Mazur P, Miyake C, Miyamoto Y, Miyata K, Miyata K, Miyazaki M, Molȩda M, Morioka T, Morita E, Muto K, Nadamoto H, Nadzikiewicz M, Nagashima K, Nakade M, Nakayama C, Nakazawa H, Nihei Y, Nikul R, Niwa S, Niwa O, Nogi M, Nomura K, Ogata D, Ohguchi H, Ohno J, Okabe M, Okada M, Okada Y, Omi N, Onodera H, Onodera K, Ooki S, Oonishi K, Oonuma H, Ooshima H, Oouchi H, Orsucci M, Paoli M, Penaud M, Perdrisot C, Petit M, Piskowski A, Płocharski A, Polis A, Polti L, Potsepnia T, Przybylski D, Pytel M, Quillet W, Remy A, Robert C, Sadowski M, Saito M, Sakuma D, Sano K, Sasaki Y, Sato N, Schneider T, Schneider C, Schwartzman K, Selivanov E, Sezaki M, Shiroishi K, Shustava I, Śniecińska A, Stalchenko E, Staroń A, Stromboni M, Studzińska W, Sugisaki H, Sukegawa T, Sumida M, Suzuki Y, Suzuki K, Suzuki R, Suzuki H, Suzuki K, Świderski W, Szudejko M, Szymaszek M, Tada J, Taguchi H, Takahashi K, Tanaka D, Tanaka G, Tanaka S, Tanino K, Tazbir K, Tcesnokova N, Tgawa N, Toda N, Tsuchiya H, Tsukamoto H, Tsushima T, Tsutsumi K, Umemura H, Uno M, Usui A, Utsumi H, Vaucelle M, Wada Y, Watanabe K, Watanabe S, Watase K, Witkowski M, Yamaki T, Yamamoto J, Yamamoto T, Yamashita M, Yanai M, Yasuda K, Yoshida Y, Yoshida A, Yoshimura K, Żmijewska M, Zuclarelli E. Measurement and comparison of individual external doses of high-school students living in Japan, France, Poland and Belarus-the 'D-shuttle' project. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2016; 36:49-66. [PMID: 26613195 DOI: 10.1088/0952-4746/36/1/49] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Twelve high schools in Japan (of which six are in Fukushima Prefecture), four in France, eight in Poland and two in Belarus cooperated in the measurement and comparison of individual external doses in 2014. In total 216 high-school students and teachers participated in the study. Each participant wore an electronic personal dosimeter 'D-shuttle' for two weeks, and kept a journal of his/her whereabouts and activities. The distributions of annual external doses estimated for each region overlap with each other, demonstrating that the personal external individual doses in locations where residence is currently allowed in Fukushima Prefecture and in Belarus are well within the range of estimated annual doses due to the terrestrial background radiation level of other regions/countries.
Collapse
|
69
|
Tsujimoto A, Barkmeier W, Takamizawa T, Miyazaki M, Latta M. Simulated gap wear of resin luting cements. Dent Mater 2016. [DOI: 10.1016/j.dental.2016.08.087] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
70
|
Fujimoto H, Ishikawa T, Satake T, Ko S, Shimizu D, Narui K, Yamada A, Sasaki T, Nagashima T, Endo I, Miyazaki M. Donor site selection and clinical outcomes of nipple-areola skin-sparing mastectomy with immediate autologous free flap reconstruction: A single-institution experience. Eur J Surg Oncol 2015; 42:369-75. [PMID: 26792708 DOI: 10.1016/j.ejso.2015.12.002] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2015] [Revised: 11/14/2015] [Accepted: 12/01/2015] [Indexed: 11/28/2022] Open
Abstract
BACKGROUND The objective of this study was to examine the clinical outcomes of immediate breast reconstruction using perforator flaps from different donor sites, and to characterize the trends among these flaps. METHODS We retrospectively reviewed 136 consecutive patients who underwent immediate breast reconstruction using free flaps after skin-sparing mastectomy (SSM) or nipple-sparing mastectomy (NSM). The whole breast was pathologically analyzed in 5-mm sections. Breast reconstruction was performed using the deep inferior epigastric perforator (DIEP) flap, gluteal artery perforator (GAP) flap, and posterior medial thigh perforator (PMTP) flap. Patient characteristics were compared among donor sites. RESULTS NSM was converted to SSM because of intraoperative subareolar tumor positivity in 7 of 107 patients. Eleven patients had positive margins in permanent sections. All but one patient had a positive horizontal margin in the peripheral direction. The 5-year recurrence-free survival rate was 91.9%. The locoregional recurrence rate was 5.1% with a mean follow-up observation period of 75 months. DEIP, GAP, and PMTP flaps were used in 64 (47.1%), 38 (27.9%), and 34 (25.0%) patients, retrospectively. DIEP flaps were used in older patients and those with a higher body mass index. GAP flaps were used in younger patients. DIEP and GAP flaps were used for larger breasts, and PMTP flaps for smaller breasts. CONCLUSION NSM or SSM with immediate perforator flap breast reconstruction is an oncologically acceptable surgical option. We believe that age, desire to have children, body mass index, and excised breast volume are valuable factors for selecting the optimal donor site.
Collapse
|
71
|
Takamizawa T, Barkmeier WW, Latta MA, Berry TP, Tsujimoto A, Miyazaki M. Simulated Wear of Self-Adhesive Resin Cements. Oper Dent 2015; 41:327-38. [PMID: 26669501 DOI: 10.2341/14-227-l] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
One of the primary areas of concern with luting agents is marginal gap erosion and attrition. The purpose of this laboratory study was to evaluate bulk and marginal slit (gap) generalized wear of self-adhesive resin cements. Three self-adhesive resin cements were used in this study: G-CEM LinkAce (LA), Maxcem Elite (ME), and RelyX Unicem2 Automix (RU). A custom stainless-steel fixture with a cavity 4.5 mm in diameter and 4 mm deep was used for simulated generalized (bulk) wear. For simulated marginal gap wear, a two-piece stainless-steel custom fixture was designed with a slit (gap) 300 μm wide and 3 mm in length. For both wear models, 20 specimens each for each of the three adhesive cements were made for both light-cure and chemical-cure techniques. The cured cements were polished with a series of carbide papers to a 4000-grit surface and subjected to 100,000 cycles using the slit (gap) wear model and 400,000 cycles for generalized (bulk) wear in a Leinfelder-Suzuki (Alabama machine) wear simulator (maximum load of 78.5 N). Flat-ended stainless-steel antagonists were used in a water slurry of poly(methylmethacrylate) beads for simulation of generalized contact-free area wear with both wear models. Before and after the wear challenges, the specimens were profiled with a Proscan 2100 noncontact profilometer, and wear (volume loss [VL] and mean facet depth [FD]) was determined using AnSur 3D software. Two-way analysis of variance (ANOVA) and Tukey post hoc tests were used for data analysis for the two wear models. Scanning electron microscopy (SEM) was used to examine polished surfaces of the resin cements and the worn surfaces after the wear challenges. The two-way ANOVA of VL using the generalized (bulk) wear model showed a significant effect among the three resin cement materials for the factor of resin cement (p<0.001) and the interaction of the cement and cure method (p<0.001), but not for the cure method (p=0.465). The two-way ANOVA for FD also found a significant difference for the factor of resin cement (p<0.001) and the interaction of the resin cement and cure method (p<0.001), but not for the cure method (p=0.277). The simulated generalized (bulk) wear for the light-cure groups was as follows: VL (mm(3)): RU 0.631 (0.094), LA 0.692 (0.112), and ME 1.046 (0.141) and FD (μm): RU 43.6 (6.5), LA 47.0 (7.7), and ME 72.5 (9.9). The simulated generalized (bulk) wear for the chemical-cure groups was as follows: VL (mm(3)): LA 0.741 (0.105), RU 1.231 (0.234), and ME 1.305 (0.143) and FD (μm): LA 50.7 (7.2), RU 84.5 (16.1), and ME 91.7 (10.2). Simulated wear using the slit (gap) model for the light-cure groups was as follows: VL (mm(3)): RU 0.030 (0.006), LA 0.031 (0.006), and ME 0.041 (0.009) and FD (μm): RU 49.6 (5.7), LA 57.2 (8.4), and ME 70.9 (10.7). The wear values for the chemical-cure slit (gap) groups were as follows: VL (mm(3)): LA 0.031 (0.004), ME 0.038 (0.007), and RU 0.045 (0.009) and FD (μm): LA 53.9 (6.7), ME 63.5 (9.1), and RU 74.2 (12.9). Pearson correlation tests revealed a strong relationship between the two wear models for the light-cure groups and a good relationship for the chemical-cure groups. The observations using SEM showed differences in filler particle shape and size among the cements and the resultant effect of the wear challenges. The worn surfaces of each cement were essentially the same for both light-cure and chemical-cure methods. The bulk wear model and new slit (gap) model for evaluation of simulated generalized wear of luting agents demonstrated significant differences (p<0.05) in relative wear among three self-adhesive resin cements and between visible light- and chemical-cure techniques.
Collapse
|
72
|
Chiba M, Miyazaki M, Ishiwata S. Quantitative analysis of the lamellarity of giant liposomes prepared by the inverted emulsion method. Biophys J 2015; 107:346-354. [PMID: 25028876 DOI: 10.1016/j.bpj.2014.05.039] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2014] [Accepted: 05/29/2014] [Indexed: 11/26/2022] Open
Abstract
The inverted emulsion method is used to prepare giant liposomes by pushing water-in-oil droplets through the oil/water interface into an aqueous medium. Due to the high encapsulation efficiency of proteins under physiological conditions and the simplicity of the protocol, it has been widely used to prepare various cell models. However, the lamellarity of liposomes prepared by this method has not been evaluated quantitatively. Here, we prepared liposomes that were partially stained with a fluorescent dye, and analyzed their fluorescence intensity under an epifluorescence microscope. The fluorescence intensities of the membranes of individual liposomes were plotted against their diameter. The plots showed discrete distributions, which were classified into several groups. The group with the lowest fluorescence intensity was determined to be unilamellar by monitoring the exchangeability of the inner and the outer solutions of the liposomes in the presence of the pore-forming toxin α-hemolysin. Increasing the lipid concentration dissolved in oil increased the number of liposomes ∼100 times. However, almost all the liposomes were unilamellar even at saturating lipid concentrations. We also investigated the effects of lipid composition and liposome content, such as highly concentrated actin filaments and Xenopus egg extracts, on the lamellarity of the liposomes. Remarkably, over 90% of the liposomes were unilamellar under all conditions examined. We conclude that the inverted emulsion method can be used to efficiently prepare giant unilamellar liposomes and is useful for designing cell models.
Collapse
|
73
|
Hashimoto M, Oohira S, Ueda Y, Miyazaki M, Isono M, Masaoka A, Takashina M, Koizumi M, Teshima T. SU-E-T-437: Four-Dimensional Treatment Planning for Lung VMAT-SBRT. Med Phys 2015. [DOI: 10.1118/1.4924798] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
74
|
Ueda Y, Hirose A, Oohira S, Isono M, Tsujii K, Miyazaki M, Kawaguchi Y, Konishi K, Teshima T. SU-E-T-68: A Quality Assurance System with a Web Camera for High Dose Rate Brachytherapy. Med Phys 2015. [DOI: 10.1118/1.4924429] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
75
|
Takamizawa T, Barkmeier WW, Tsujimoto A, Scheidel DD, Erickson RL, Latta MA, Miyazaki M. Effect of Phosphoric Acid Pre-etching on Fatigue Limits of Self-etching Adhesives. Oper Dent 2015; 40:379-95. [DOI: 10.2341/13-252-l] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
The purpose of this study was to use shear bond strength (SBS) and shear fatigue limit (SFL) testing to determine the effect of phosphoric acid pre-etching of enamel and dentin prior to application of self-etch adhesives for bonding resin composite to these substrates. Three self-etch adhesives—1) G- ænial Bond (GC Corporation, Tokyo, Japan); 2) OptiBond XTR (Kerr Corp, Orange, CA, USA); and 3) Scotchbond Universal (3M ESPE Dental Products, St Paul, MN, USA)—were used to bond Z100 Restorative resin composite to enamel and dentin surfaces. A stainless-steel metal ring with an inner diameter of 2.4 mm was used to bond the resin composite to flat-ground (4000 grit) tooth surfaces for determination of both SBS and SFL. Fifteen specimens each were used to determine initial SBS to human enamel/dentin, with and without pre-etching with a 35% phosphoric acid (Ultra-Etch, Ultradent Products Inc, South Jordan, UT, USA) for 15 seconds prior to the application of the adhesives. A staircase method of fatigue testing (25 specimens for each test) was then used to determine the SFL of resin composite bonded to enamel/dentin using a frequency of 10 Hz for 50,000 cycles or until failure occurred. A two-way analysis of variance and Tukey post hoc test were used for analysis of SBS data, and a modified t-test with Bonferroni correction was used for the SFL data. Scanning electron microscopy was used to examine the area of the bonded restorative/tooth interface. For all three adhesive systems, phosphoric acid pre-etching of enamel demonstrated significantly higher (p<0.05) SBS and SFL with pre-etching than it did without pre-etching. The SBS and SFL of dentin bonds decreased with phosphoric acid pre-etching. The SBS and SFL of bonds using phosphoric acid prior to application of self-etching adhesives clearly demonstrated different tendencies between enamel and dentin. The effect of using phosphoric acid, prior to the application of the self-etching adhesives, on SBS and SFL was dependent on the adhesive material and tooth substrate and should be carefully considered in clinical situations.
Collapse
|