51
|
Grassmann JP, Hakimi M, Gehrmann SV, Betsch M, Kröpil P, Wild M, Windolf J, Jungbluth P. The treatment of the acute Essex-Lopresti injury. Bone Joint J 2014; 96-B:1385-91. [PMID: 25274926 DOI: 10.1302/0301-620x.96b10.33334] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
The Essex-Lopresti injury (ELI) of the forearm is a rare and serious condition which is often overlooked, leading to a poor outcome. The purpose of this retrospective case study was to establish whether early surgery can give good medium-term results. From a group of 295 patients with a fracture of the radial head, 12 patients were diagnosed with ELI on MRI which confirmed injury to the interosseous membrane (IOM) and ligament (IOL). They were treated by reduction and temporary Kirschner (K)-wire stabilisation of the distal radioulnar joint (DRUJ). In addition, eight patients had a radial head replacement, and two a radial head reconstruction. All patients were examined clinically and radiologically 59 months (25 to 90) after surgery when the mean Mayo Modified Wrist Score (MMWS) was 88.4 (78 to 94), the mean Mayo Elbow Performance Scores (MEPS) 86.7 (77 to 95) and the mean disabilities of arm, shoulder and hand (DASH) score 20.5 (16 to 31): all of these indicate a good outcome. In case of a high index of suspicion for ELI in patients with a radial head fracture, we recommend the following: confirmation of IOM and IOL injury with an early MRI scan; early surgery with reduction and temporary K-wire stabilisation of the DRUJ; preservation of the radial head if at all possible or replacement if not, and functional bracing in supination. This will increase the prospect of a good result, and avoid the complications of a missed diagnosis and the difficulties of late treatment.
Collapse
|
52
|
Böckler D, Peters A, Pfeiffer S, Kovacs B, Geisbüsch P, Bischoff M, Müller-Eschner M, Hakimi M. Nellix® Endovascular Aneurysm Sealing (EVAS) – eine neue Technologie zur endovaskulären Ausschaltung infrarenaler Aortenaneurysmen. Zentralbl Chir 2014. [DOI: 10.1055/s-0034-1383254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
53
|
Böckler D, Peters AS, Pfeiffer S, Kovacs B, Geisbüsch P, Bischoff MS, Müller-Eschner M, Hakimi M, Pfeiffer S. [Nellix® endovascular aneurysm sealing (EVAS) - a new technology for endovascular management of infrarenal aortic aneurysms]. Zentralbl Chir 2014; 139:562-8. [PMID: 25313891 DOI: 10.1055/s-0034-1383084] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
BACKGROUND Recently used endografts for envascular aneurysm repair (EVAR) exclude the pathology by fixation at both the proximal and distal landing zone. Due to endoleaks and migration EVAR is associated with a relevant rate of secondary interventions. The Nellix® system (Endologix Inc., CA, USA) was developed to seal the complete aneurysm using a polymer filling, therefore stabilising endograft-position and reducing the rate of endoleaks and reinterventions. The present contribution introduces the method, describes the technique of implantation and presents the first clinical results. Material und Methods: The Nellix system consists of two balloon-expandable stent grafts made of a cobalt-chromium composition, surrounded with ePTFE and the so-called endobags. During the implantation each endobag is filled with a non-biodegradable polymer, sealing the aneurysm lumina including the proximal and distal landing zone. Hence, lumbar arteries will be sealed to reduce the probability of a type II endoleak. RESULTS Longterm durability as well as the structural integrity of the Nellix system has been proven over 4 years in sheep experiments. The technical success in a multicentre, prospective registry was 94% without the appearance of severe adverse events (migration, occlusion, secondary endoleak). CONCLUSION EVAS is a new and different concept of endovascular AAA repair. Recent clinical data of the Nellix system are promising showing a high technical success rate while the need for secondary intervention is low. Further studies in larger cohorts are needed.
Collapse
|
54
|
Khajeh Aminian M, Hakimi M. Surface modification by loading alkaline hydroxides to enhance the photoactivity of WO3. Catal Sci Technol 2014. [DOI: 10.1039/c3cy00781b] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
55
|
Jungbluth P, Hakimi AR, Grassmann JP, Schneppendahl J, Betsch M, Kröpil P, Thelen S, Sager M, Herten M, Wild M, Windolf J, Hakimi M. The early phase influence of bone marrow concentrate on metaphyseal bone healing. Injury 2013; 44:1285-94. [PMID: 23684350 DOI: 10.1016/j.injury.2013.04.015] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/21/2013] [Revised: 03/30/2013] [Accepted: 04/14/2013] [Indexed: 02/02/2023]
Abstract
Bone marrow concentrate (BMC) contains high densities of progenitor cells. Therefore, in critical size defects BMC may have the potency to support bone healing. The aim of this study was to investigate the effect of BMC in combination with calcium phosphate granules (CPG) on bone defect healing in a metaphyseal long bone defect in mini-pigs. A metaphyseal critical-size bone defect at the proximal tibia of 24 mini-pigs was filled with CPG combined with BMC, CPG solely (control group) or with an autograft. Radiological and histomorphometrical evaluations after 6 weeks (42 days) showed significantly more bone formation in the BMC group in the central area of the defect zone and the cortical defect zone compared to the CPG group. At the same time the resorption rate of CPG increased significantly in the BMC group. Nevertheless, compared to the BMC group the autograft group showed a significantly higher new bone formation radiologically and histomorphometrically. In BMC the count of mononuclear cells was significantly higher compared to the bone marrow aspirate (3.5-fold). The mesenchymal progenitor cell characteristics of the cells in BMC were confirmed by flow cytometry. Cells from BMC created significantly larger colonies of alkaline phosphatase-positive colony forming units (CFU-ALP) (4.4-fold) compared to cells from bone marrow aspirate. Nevertheless, even in the BMC group complete osseous bridging was only detectable in isolated instances of the bone defects. Within the limitations of this study the BMC+CPG composite promotes bone regeneration in the early phase of bone healing significantly better than the isolated application of CPG. However, the addition of BMC does not lead to a solid fusion of the defect in the early phase of bone healing an still does not represent an equal alternative to autologous bone.
Collapse
|
56
|
Geisbüsch P, Attigah N, Hyhlik-Dürr A, Hakimi M, Müller-Eschner M, Böckler D. Decision-making and techniques in hypogastric artery revascularization. THE JOURNAL OF CARDIOVASCULAR SURGERY 2013; 54:71-79. [PMID: 23443591] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
The aim of this article was to describe and discuss the currently available endovascular and open surgical techniques to preserve or occlude the hypogastric artery during aortoiliac aneurysm repair and thus support the process of decision-making in hypogastric artery revascularization.
Collapse
|
57
|
Schneppendahl J, Lefering R, Kühne CA, Ruchholz S, Hakimi M, Witte I, Lögters T, Windolf J, Flohé S. [Interhospital transfer of severely injured patients in Germany. Evaluation of the DGU trauma register]. Unfallchirurg 2013; 115:717-24. [PMID: 21165586 DOI: 10.1007/s00113-010-1914-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
BACKGROUND The TraumaNetzwerk(D) DGU was founded 3 years ago and since then the majority of trauma centers have been registered and organized into regional trauma network services (TNW). Within these networks assessment criteria for transferring patients to higher level hospitals are defined. The purpose of this study was to evaluate the incidence, causes, implications and quality of care for patients with major trauma who were transferred for definitive treatment before implementation of the TraumaNetzwerk(D) DGU in Germany. PATIENT AND METHODS The data of 19,035 patients listed in the German Trauma Register of the German Society for Trauma Surgery (DGU, 2002-2007) were analyzed. Patients with an injury severity score (ISS) >9 and a blood pressure documented on admission were included into the study. Data were allocated according to patients where therapy was performed completely in the primary hospital of admission (group I; n=16,033; 84.2%) and patients transferred after primary care from one hospital to another centre for definitive care (group II; n=3,002; 15.8%). Comparative parameters were the pattern and severity of injury, physiological state on admission and clinical outcome. RESULTS Mean ISS and percentage of patients with an ISS ≥25 did not differ significantly between groups. Of the patients who were transferred to a higher level trauma centre (group II) 20.7% needed catecholamines on admission, 10.1% were in shock (blood pressure <90 mmHg) and 2.5% of the patients underwent resuscitation in the emergency department. Patients of group II had a considerably longer hospital stay (31.2±35.5 days) than patients of group I (24.8±27.1 days). Furthermore, treatment costs were significantly higher for group II (I: EUR 23,870; II: EUR 26,054). CONCLUSIONS A relevant percentage of patients transferred from one hospital to another were hemodynamically and clinically unstable. To what extent the quality of patient transfer and therefore major trauma care is improved by the implementation of regional trauma networks in Germany remains to be seen over the next years.
Collapse
|
58
|
White J, Zubairy A, Hakimi M. Arthroscopic thermal capsular shrinkage: a successful treatment option for patients with chronic lateral ankle instability? BMC Proc 2012. [PMCID: PMC3426020 DOI: 10.1186/1753-6561-6-s4-o32] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
59
|
Demirel S, Macek L, Bruijnen H, Hakimi M, Böckler D, Attigah N. Eversion Carotid Endarterectomy is Associated with Decreased Baroreceptor Sensitivity Compared to the Conventional Technique. Eur J Vasc Endovasc Surg 2012; 44:1-8. [DOI: 10.1016/j.ejvs.2012.04.009] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2011] [Accepted: 04/10/2012] [Indexed: 10/28/2022]
|
60
|
Kröpil P, Riegger C, Rubbert C, Lanzman RS, Miese FR, Hakimi AR, Jungbluth P, Becker J, Hakimi M, Antoch G, Scherer A. Quantitative Messung der Knochendefektheilung mittels Digitaler Volumentomographie (DVT) am Tiermodell. ROFO-FORTSCHR RONTG 2012. [DOI: 10.1055/s-0032-1311295] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
61
|
Gehrmann SV, Grassmann JP, Schneppendahl J, Kaufmann RA, Windolf J, Hakimi M, Schädel-Höpfner M. [Treatment strategy for carpometacarpal fracture dislocation]. Unfallchirurg 2012; 114:559-64. [PMID: 21698425 DOI: 10.1007/s00113-011-2006-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Carpometacarpal (CMC) fracture dislocations of the 2nd through 5th ray are rare injuries whose extent is regularly underestimated in the initial radiographic evaluation of the hand. Obtaining a computed tomography scan is imperative due to the radiographic underrepresentation of the full bone and joint injury. Restoration of bone and joint anatomy of the affected region is of paramount import to prevent joint deterioration and loss of hand durability and dexterity. Early surgical intervention can lead to good functional results. Different operative treatment strategies exist with a common approach being Kirschner wire, screw or plate fixation after closed or open fracture reduction and joint relocation.
Collapse
|
62
|
Hyhlik-Dürr A, Bischoff MS, Hakimi M, Von Tengg-Kobligk H, Böckler D. Technical aspects of EVAR for infrarenal AAA. THE JOURNAL OF CARDIOVASCULAR SURGERY 2012; 53:111-118. [PMID: 22433730] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Technical aspects are crucial for planning and performing successful endovascular repair of abdominal aortic aneurysms (AAA). Planning should be based on high-quality computed tomography angiography scans with a slice thickness of ≤ 1 mm. However, even without a workstation for image postprocessing, important angle estimations can be easily performed. Several devices are available today to treat abdominal aneurysms. In most elective cases all currently available 3rd generation devices perform comparably if minimal requirements are kept in mind. A safe and technically precise implantation requires cooperation with the involved anesthesiologist in order to manage anticoagulation, blood pressure regulation in general and in currently evolving regional anesthesia. Modern endograft implantation involves highly technical resources, for example guide wires or catheters. Beside patient selection, an optimal procedure planning, graft model choice and endovascular skills are mandatory aspects. In the near future, further improvements in device design and deployment mechanism will allow better device alignment, paving the way for an even broader application of endovascular aneurysm repair (EVAR).
Collapse
|
63
|
Lögters T, Fürst G, Hakimi M, Windolf J, Schädel-Höpfner M. Die intraläsionale Sklerosierung venöser Malformationen an der Hand mit Natriumtetradecylsulfat. HANDCHIR MIKROCHIR P 2011; 43:356-60. [DOI: 10.1055/s-0031-1280798] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022] Open
|
64
|
Jungbluth P, Wild M, Hakimi M, Betsch M, Dassler K, Möller-Herckenhoff L, Windolf J, Ritz-Timme S, Graß H. [Quality of documentation and care for victims of violence for the example of a trauma surgery emergency department in a major city]. ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE 2011; 150:89-97. [PMID: 22065376 DOI: 10.1055/s-0031-1280168] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
Abstract
BACKGROUND People who have become victims of violence have manifold problems. Besides medical diagnostics and therapy, it is necessary to recognise the situation in which these patients have become such victims, to document the consequences of this violence for use in court and to offer further assistance. Victims of violence often contact primarily a trauma ambulance. The optimisation of the medical treatment of the victims is a relevant traumatological topic, which so far has received only very scant attention. Therefore the aim of this study was to evaluate the necessity for an interdisciplinary combination of treatments for the targeted treatment of these victims. MATERIAL AND METHODS Using a standardised data card a retrospective data analysis of all out-patients and all in-patients of a trauma centre with regard to the existence of a violent context was carried out for the year 2004. All such cases were included and the data were evaluated descriptively according to age, gender, information about the act of violence, consequences thereof, type and scope of the diagnostic findings, as well as inducements for further measures. In this context we differentiated between "domestic violence" and "public violence". RESULTS The data of 7132 patients were evaluated. Altogether 347 victims of violence were identified (among them 109 victims of "public violence", 59 victims of domestic violence, and 179 cases that could not be allocated clearly). This results in a quota of 4.9% of all patients treated. The average age of the victims was 30.6 years. It was striking that in many cases the anamnesis and documentation were rather fragmentary. CONCLUSION A very high percentage of victims of violence could be found among the patients needing traumatological treatment. With regard to the fragmentary care there is an enormous need for medical training and interdisciplinary treatment of victims of violence.
Collapse
|
65
|
Demirel S, Hyhlik-Dürr A, Attigah N, Hakimi M, von Tengg-Kobligk H, Böckler D. [Correction: Vascular Surgery in the Elderly - Recommendations for Clinical Practice]. Zentralbl Chir 2011; 136:e1. [PMID: 32126733 DOI: 10.1055/a-1126-7036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
66
|
Ng N, Hakimi M, Wilopo S, Byass P, Wall S. SP4-16 Does education modify the association between self-rated health and mortality among older people in Indonesia? Br J Soc Med 2011. [DOI: 10.1136/jech.2011.142976p.10] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
67
|
Riegger C, Jungbluth P, Hakimi M, Lanzman RS, Heusner T, Scherer A, Antoch G, Kröpil P. Quantitative Messung der Knochendefektheilung mittels Multidetektor-Computertomographie am Tiermodell. ROFO-FORTSCHR RONTG 2011. [DOI: 10.1055/s-0031-1279299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
68
|
Wild M, Thelen S, Jungbluth P, Betsch M, Miersch D, Windolf J, Hakimi M. Fixed-angle plates in patella fractures - a pilot cadaver study. Eur J Med Res 2011; 16:41-6. [PMID: 21345769 PMCID: PMC3351948 DOI: 10.1186/2047-783x-16-1-41] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Objective Modified anterior tension wiring with K-wires and cannulated lag screws with anterior tension wiring are currently the fixation of choice for patellar fractures. Failure of fixation, migration of the wires, postoperative pain and resulting revision surgery, however, are not uncommon. After preliminary biomechanical testing of a new fixed-angle plate system especially designed for fixation of patella fractures the aim of this study was to evaluate the surgical and anatomical feasibility of implanting such a plate-device at the human patella. Methods In six fresh unfixed female cadavers without history of previous fractures around the knee (average age 88.8 years) a bilateral fixed-angle plate fixation of the patella was carried out after previous placement of a transverse central osteotomy. Operative time, intra-operative problems, degree of retropatellar arthritis (following Outerbridge), quality of reduction and existence of any intraarticular screw placement have been raised. In addition, lateral and anteroposterior radiographs of all specimens were made. Results Due to the high average age of 88.8 years no patella showed an unimpaired retropatellar articular surface and all were severely osteoporotic, which made a secure fixation of the reduction forceps during surgery difficult. The operation time averaged 49 minutes (range: 36-65). Although in postoperative X-rays the fracture gap between the fragments was still visible, the analysis of the retropatellar surface showed no residual articular step or dehiscence > 0.5 mm. Also in a total of 24 inserted screws not one intraarticular malposition was found. No intraoperative complications were noticed. Conclusions Osteosynthesis of a medial third patella fracture with a bilateral fixed-angle plate-device is surgically and anatomically feasible without difficulties. Further studies have to depict whether the bilateral fixed-angle plate-osteosynthesis of the patella displays advantages over the established operative procedures.
Collapse
|
69
|
Schädel-Höpfner M, Windolf J, Lögters TT, Hakimi M, Celik I. Flexor tendon repair using a new suture technique: a comparative in vitro biomechanical study. Eur J Trauma Emerg Surg 2011; 37:79-84. [PMID: 26814755 DOI: 10.1007/s00068-010-0019-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2009] [Accepted: 01/30/2010] [Indexed: 11/25/2022]
Abstract
INTRODUCTION The purpose of this experimental study was to evaluate the biomechanical characteristics of two new four-strand core suture techniques for flexor tendon repair. MATERIALS AND METHODS The two new suture techniques (Marburg 1, Marburg 2) are characterized by four longitudinal stitches which are anchored by a circular or semicircular suture. They were compared with three commonly used core suture techniques (modified Kessler, Tsuge, Bunnell). Fifty porcine flexor tendons were randomly assigned to one of the five core suture techniques. Outcome measures included ultimate tensile strength, maximum of lengthening, mode of failure and 1 mm gap formation force. RESULTS The highest ultimate tensile strength was found for the modified Kessler technique (115 N). Both new techniques showed an ultimate load exceeding 50 N (57 N for Marburg 1, 54 N for Marburg 2). The Marburg 1 technique showed the highest gap resistance of all tested suture techniques. The Bunnell and Tsuge core suture techniques produced the poorest mechanical performance. CONCLUSION From these experimental results, the new Marburg 1 core suture technique can be considered for flexor tendon repair in a clinical setting with the use of active motion protocols.
Collapse
|
70
|
Demirel S, Hyhlik-Dürr A, Attigah N, Hakimi M, Tengg-Kobligk H, Böckler D. Gefäßchirurgie im Alter – Handlungsempfehlungen für die chirurgische Praxis. Zentralbl Chir 2011; 136:471-479. [DOI: 10.1055/s-0030-1262626] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
71
|
Perwitasari DA, Atthobari J, Dwiprahasto I, Hakimi M, Gelderblom H, Putter H, Nortier JWR, Guchelaar HJ, Kaptein AA. Translation and Validation of EORTC QLQ-C30 into Indonesian Version for Cancer Patients in Indonesia. Jpn J Clin Oncol 2011; 41:519-29. [DOI: 10.1093/jjco/hyq243] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
72
|
Attigah N, Kutter J, Demirel S, Hakimi M, Hinz U, Motsch J, Böckler D. Assessment of Patients’ Satisfaction in Carotid Surgery under Local Anaesthesia by Psychometrical Testing – A Prospective Cohort Study. Eur J Vasc Endovasc Surg 2011; 41:76-82. [DOI: 10.1016/j.ejvs.2010.08.020] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2010] [Accepted: 08/20/2010] [Indexed: 10/19/2022]
|
73
|
Hakimi M, Mardani Z, Moeini K, Minoura M, Raissi H. Synthesis, Characterization and Crystal Structure of a Binuclear Cadmium Iodide Complex with a Multi-N-donor Oxazolidine Ligand. ZEITSCHRIFT FUR NATURFORSCHUNG SECTION B-A JOURNAL OF CHEMICAL SCIENCES 2011. [DOI: 10.5560/znb.2011.66b1122] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
74
|
Chan J, Nirwati H, Triasih R, Bogdanovic-Sakran N, Soenarto Y, Hakimi M, Duke T, Buttery JP, Bines JE, Bishop RF, Kirkwood CD, Danchin MD. Maternal antibodies to rotavirus: could they interfere with live rotavirus vaccines in developing countries? Vaccine 2010; 29:1242-7. [PMID: 21147127 DOI: 10.1016/j.vaccine.2010.11.087] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2010] [Revised: 11/25/2010] [Accepted: 11/26/2010] [Indexed: 11/25/2022]
Abstract
INTRODUCTION Past experience with live oral vaccines including licensed rotavirus vaccines demonstrates a trend towards reduced vaccine efficacy in developing countries compared with developed countries. The reasons behind this disparity are not well understood. Transplacental transfer of maternal antibodies and breast milk ingestion may attenuate vaccine responses in infants in developing countries where rotavirus infections are endemic, and maternal antibody levels are high. We examined the prevalence and level of rotavirus antibody in maternal and cord serum, colostrum and breast milk in a developing country setting. METHODS 100 mother-infant pairs were prospectively recruited from December 2008 to February 2009 at Dr. Sardjito Hospital, Yogyakarta, Indonesia. Maternal and cord sera were collected during delivery. Colostrum and transitional breast milk were collected between day 0-3 and day 7-10 postpartum respectively. Rotavirus-specific IgA and IgG were estimated for all specimens and virus neutralization assays were conducted on a subset of milk specimens. RESULTS All maternal and cord serum samples were positive for rotavirus-specific IgG antibodies with a strong correlation between levels of rotavirus-specific IgG in mothers and levels transferred to infants in cord blood (r=0.86; p=0.001). 78% of colostrum and 67% of transitional breast milk specimens were positive for rotavirus-specific IgA. There was a median 4-fold decrease in rotavirus-specific IgA from colostrum to transitional breast milk. Neutralizing antibodies were present in 56% of colostrum specimens assayed (19/34) and in 41% of transitional milk specimens assayed (14/34). CONCLUSIONS Maternal serum and breast milk antibodies to rotavirus are highly prevalent in a developing country setting. Evaluation of the impact of maternal anti-rotavirus serum and breast milk antibody upon vaccine immunogenicity would help to inform rotavirus vaccination strategies, especially in developing settings.
Collapse
|
75
|
Hakimi M, Jungbluth P, Thelen S, Betsch M, Linhart W, Flohé S, Windolf J, Wild M. Platelet-rich-Plasma in Kombination mit autologer Spongiosa. Unfallchirurg 2010; 114:998-1006. [DOI: 10.1007/s00113-010-1836-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|