51
|
Ravichandran R. Formulation of nanosuspensions of gymnemic acids for oral administration. ACTA ACUST UNITED AC 2010. [DOI: 10.1504/ijnp.2010.037135] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
52
|
Ravichandran R. Preparation and characterisation of curcumin nanosuspension for enhanced solubility and dissolution velocity. ACTA ACUST UNITED AC 2010. [DOI: 10.1504/ijnbm.2010.037803] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
53
|
Rajesh S, Porkodi R, Sasikala J, Rukmangatharajan S, Rajeswari S, Ravichandran R, Balameena S, Selvam TNT. What is your diagnosis? INDIAN JOURNAL OF RHEUMATOLOGY 2009. [DOI: 10.1016/s0973-3698(09)60116-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
|
54
|
Pandiperumal S, Porkodi R, Sasikala J, Rukmangatharajan S, Rajeswari S, Ravichandran R, Tamilselvam TN, Balameena S. P49 Clinical profile of mononeuritis multiplex in systemic connective tissue diseases. INDIAN JOURNAL OF RHEUMATOLOGY 2009. [DOI: 10.1016/s0973-3698(09)60067-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022] Open
|
55
|
Balameena S, Porkodi R, Rukmangatharajan R, Rajeswari S, Ravichandran R. P12 Kawasaki disease-newer horizon a case series. INDIAN JOURNAL OF RHEUMATOLOGY 2009. [DOI: 10.1016/s0973-3698(09)60030-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
|
56
|
Rajeswari S, Panchapakesa RC, Porkodi R, Rukmanghtharajan S, Ravichandran R, Tamilselvan TN, Balameena S, Sasikala J. O7 Aorta, aneurysms and aortoarteritis. INDIAN JOURNAL OF RHEUMATOLOGY 2009. [DOI: 10.1016/s0973-3698(09)60009-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
|
57
|
Rajesh S, Porkodi R, Sasikala J, Rukmangatharajan S, Rajeswari S, Ravichandran R, Balameena S, TamilSelvam TN. P52 Autoimmunity in geriatric population: clinical characteristics. INDIAN JOURNAL OF RHEUMATOLOGY 2009. [DOI: 10.1016/s0973-3698(09)60070-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
|
58
|
Ravichandran R. Has the time come for doing away with Cobalt-60 teletherapy for cancer treatments. J Med Phys 2009; 34:63-5. [PMID: 20098538 PMCID: PMC2805891 DOI: 10.4103/0971-6203.51931] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
59
|
Krishnamurthy K, Sivakumar SS, Davis CA, Ravichandran R, El Ghamrawy K. Formulation and initial experience on patient specific quality assurance for clinical implementation of dynamic IMRT. Gulf J Oncolog 2009:44-48. [PMID: 20084785] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Intensity modulated radiotherapy (IMRT) is an advanced form of 3D conformal radiotherapy combining several intensity modulated beams to deliver the prescribed dose to the target with precision, sparing the adjacent normal tissue structures. The complex nature of IMRT delivery needs a precise patient specific quality assurance (QA), proper verification of dosimetry and treatment. QA procedures are important measures to ensure that the treatment can be delivered according to the treatment plan. In this report, we are presenting a formulation of a proposed protocol and results of patient specific QA carried on two IMRT plans. The QA consists of an absolute dosimetry, film dosimetry and dynalog files verification of treatment plans. The absolute doses, planar and fluence doses calculated by the TPS are compared with the measured values. The dynalog files recorded during the treatment delivery of two plans were analysed. The measured error in absolute dose is <3% in both the plans. An average of >98% of counts are having <0.1 cm errors in dMLC positions. The average RMS value of leaf motions is <0.05 cm in both the cases. The errors in film dosimetry are <3%. All the results obtained are comparable to the standard values and well within the acceptable limits. The paper outlines the minimum procedures required for the patient specific QA measurements for the clinical implementation of IMRT. The measurements help to understand and confirm the accuracy of IMRT delivery system.
Collapse
|
60
|
Ravichandran R, Binukumar JP, Sivakumar SS, Krishnamurthy K, Davis CA. Extrapolation chamber mounted on perspex for calibration of high energy photon and electron beams from a clinical linear accelerator. J Med Phys 2009; 34:31-6. [PMID: 20126563 PMCID: PMC2804145 DOI: 10.4103/0971-6203.48718] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2008] [Accepted: 12/30/2008] [Indexed: 11/04/2022] Open
Abstract
The objective of the present study is to establish radiation standards for absorbed doses, for clinical high energy linear accelerator beams. In the nonavailability of a cobalt-60 beam for arriving at Nd, water values for thimble chambers, we investigated the efficacy of perspex mounted extrapolation chamber (EC) used earlier for low energy x-rays and beta dosimetry. Extrapolation chamber with facility for achieving variable electrode separations 10.5mm to 0.5mm using micrometer screw was used for calibrations. Photon beams 6 MV and 15 MV and electron beams 6 MeV and 15 MeV from Varian Clinac linacs were calibrated. Absorbed Dose estimates to Perspex were converted into dose to solid water for comparison with FC 65 ionisation chamber measurements in water. Measurements made during the period December 2006 to June 2008 are considered for evaluation. Uncorrected ionization readings of EC for all the radiation beams over the entire period were within 2% showing the consistency of measurements. Absorbed doses estimated by EC were in good agreement with in-water calibrations within 2% for photons and electron beams. The present results suggest that extrapolation chambers can be considered as an independent measuring system for absorbed dose in addition to Farmer type ion chambers. In the absence of standard beam quality (Co-60 radiations as reference Quality for Nd,water) the possibility of keeping EC as Primary Standards for absorbed dose calibrations in high energy radiation beams from linacs should be explored. As there are neither Standard Laboratories nor SSDL available in our country, we look forward to keep EC as Local Standard for hospital chamber calibrations. We are also participating in the IAEA mailed TLD intercomparison programme for quality audit of existing status of radiation dosimetry in high energy linac beams. The performance of EC has to be confirmed with cobalt-60 beams by a separate study, as linacs are susceptible for minor variations in dose output on different days.
Collapse
|
61
|
Perumai SP, Porkodi R, Rukmangatharajan S, Rajeswari S, Ravichandran R, Balameena S, Tamilselvan TN, Sasikala J. O29 Short term outcome study of systemic sclerosis with pulse cyclophosphamide. INDIAN JOURNAL OF RHEUMATOLOGY 2008. [DOI: 10.1016/s0973-3698(10)60403-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
62
|
Jagannathan K, Porkodi R, Rukmangatharajan S, Rajeswari S, Ravichandran R, Sasikala J, Balameena S, Tamilselvam TN. P27 Clinical and laboratory profile of adult onset Still's disease. INDIAN JOURNAL OF RHEUMATOLOGY 2008. [DOI: 10.1016/s0973-3698(10)60471-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
|
63
|
Singh JR, Sathishkumar V, Porkodi R, Sasikala J, Rukmangatharajan S, Rajeswari S, Ravichandran R, Balameena S, Tamilselvam TN. P31 Psoriatic arthritis: a clinicolaboratory study with special reference to USG of entheses. INDIAN JOURNAL OF RHEUMATOLOGY 2008. [DOI: 10.1016/s0973-3698(10)60475-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
|
64
|
Rajeshwari S, Rajendran CP, Porkodi R, Rukmangatharajan S, Ravichandran R, Sasikala J. P52 Different strokes—nervous system and Takayasu's arteritis. INDIAN JOURNAL OF RHEUMATOLOGY 2008. [DOI: 10.1016/s0973-3698(10)60496-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
|
65
|
Ravichandran R, Vasanthy N, Rajendran C P, Sasikala J, Rukmangatharajan S, Boopathy K S, Kirthi R. Clinical and articular presentation of juvenile idiopathic arthritis. Pediatr Rheumatol Online J 2008. [PMCID: PMC3334141 DOI: 10.1186/1546-0096-6-s1-p78] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
66
|
Ravichandran R, Binukumar JP, Sivakumar SS, Krishnamurthy K, Davis CA. A method for estimation of accuracy of dose delivery with dynamic slit windows in medical linear accelerators. J Med Phys 2008; 33:127-9. [PMID: 19893703 PMCID: PMC2772038 DOI: 10.4103/0971-6203.42768] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2008] [Accepted: 05/29/2008] [Indexed: 11/22/2022] Open
Abstract
Intensity-modulated radiotherapy (IMRT) clinical dose delivery is based on computer-controlled multileaf movements at different velocities. To test the accuracy of modulation of the beam periodically, quality assurance (QA) methods are necessary. Using a cylindrical phantom, dose delivery was checked at a constant geometry for sweeping fields. Repeated measurements with an in-house designed methodology over a period of 1 year indicate that the method is very sensitive to check the proper functioning of such dose delivery in medical linacs. A cylindrical perspex phantom with facility to accurately position a 0.6-cc (FC 65) ion chamber at constant depth at isocenter, (SA 24 constancy check tool phantom for MU check, Scanditronix Wellhofer) was used. Dosimeter readings were integrated for 4-mm, 10-mm, 20-mm sweeping fields and for 3 angular positions of the gantry periodically. Consistency of standard sweeping field output (10-mm slit width) and the ratios of outputs against other slit widths over a long period were reported. A 10-mm sweeping field output was found reproducible within an accuracy of 0.03% (n = 25) over 1 year. Four-millimeter, 20-mm outputs expressed as ratio with respect to 10-mm sweep output remained within a mean deviation of 0.2% and 0.03% respectively. Outputs at 3 gantry angles remained within 0.5%, showing that the effect of dynamic movements of multileaf collimator (MLC) on the output is minimal for angular positions of gantry. This method of QA is very simple and is recommended in addition to individual patient QA measurements, which reflect the accuracy of dose planning system. In addition to standard output and energy checks of linacs, the above measurements can be complemented so as to check proper functioning of multileaf collimator for dynamic field dose delivery.
Collapse
|
67
|
Sivakumar SS, Krishnamurthy K, Davis CA, Ravichandran R, Kannadhasan S, Biunkumar JP, El Ghamrawy K. Clinical implementation of dynamic intensity-modulated radiotherapy: Dosimetric aspects and initial experience. J Med Phys 2008; 33:64-71. [PMID: 19893693 PMCID: PMC2772030 DOI: 10.4103/0971-6203.41195] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2008] [Accepted: 04/12/2008] [Indexed: 11/04/2022] Open
Abstract
This paper describes the initial experience of quality assurance (QA) tests performed on the millennium multi-leaf collimator (mMLC) for clinical implementation of intensity-modulated radiotherapy (IMRT) using sliding window technique. The various QA tests verified the mechanical and dosimetric stability of the mMLC of linear accelerator when operated in dynamic mode (dMLC). The mechanical QA tests also verified the positional accuracy and kinetic properties of the dMLC. The stability of dMLC was analyzed qualitatively and quantitatively using radiographic film and Omnipro IMRT software. The output stability, variation in output for different sweeping gap widths, and dosimetric leaf separation were measured. Dose delivery with IMRT was verified against the dose computed by the treatment planning system (TPS). Monitor units (MUs) calculated by the planning system for the IMRT were cross-checked with independent commercial dose management software. Visual inspection and qualitative analysis showed that the leaf positioning accuracy was well within the acceptable limits. Dosimetric QA tests confirmed the dosimetric stability of the mMLC in dynamic mode. The verification of MUs using commercial software confirmed the reliability of the IMRT planning system for dose computation. The dosimetric measurements validated the fractional dose delivery.
Collapse
|
68
|
Arul Rajamurugan P, Panchapakesa Rajendran C, Rukmangatharajan S, Kanakarani P, Rajeswari S, Ravichandran R. Letter o the Editor: Aortic dissection in a case of systemic lupus erythematosus. Lupus 2007; 16:1001-3. [DOI: 10.1177/0961203307081996] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
69
|
Samikrishnan P, Rajendran CP, Ammamuthu S, Rukmangatharajan S, Rajeswari S, Ravichandran R, Sasikala J, Vasanthi N. P5 Study of hearing impairment in rheumatoid arthritis. INDIAN JOURNAL OF RHEUMATOLOGY 2007. [DOI: 10.1016/s0973-3698(10)60332-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
|
70
|
Ravichandran R, Ledge GS, Rajendran CP, Vasanthi N, Rajan SR, Kanakarani P, Rajeswari S. O2 The spectrum of juvenile rheumatoid arthritis and juvenile idiopathic arthritis in Chennai study. INDIAN JOURNAL OF RHEUMATOLOGY 2007. [DOI: 10.1016/s0973-3698(10)60317-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
|
71
|
Kirthi R, Rajendran CP, Sasikala J, Rukmangatharajan S, Kanagarani P, Rajeswari S, Ravichandran R, Vasanthy N. P4 Peripheral gangrene in rheumatic diseases. INDIAN JOURNAL OF RHEUMATOLOGY 2007. [DOI: 10.1016/s0973-3698(10)60331-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
72
|
Rajeswari S, Rajendran CP, Rukmangatharajan S, Ravichandran R, Sasikala J, Vasanthi N. P25 It's not child's play—Takayasu's in children from Madras Medical College, Chennai. INDIAN JOURNAL OF RHEUMATOLOGY 2007. [DOI: 10.1016/s0973-3698(10)60352-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
|
73
|
Ravichandran R, Binukumar JP, Davis CA, Krishnamurthy K, Sivakumar SS. Evaluation methods for detecting changes in beam output and energy in radiation beams from high-energy linear accelerators. J Med Phys 2007; 32:92-6. [PMID: 21157527 PMCID: PMC3000505 DOI: 10.4103/0971-6203.35720] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2007] [Accepted: 06/19/2007] [Indexed: 11/25/2022] Open
Abstract
There is need for simple methods for checking consistency of beam outputs and energy in linear accelerators used for radiotherapy. A method was designed by the department using perspex phantom with which the dosimetric data of two medical linear accelerators (Clinac 600 CD, Clinac 2300 CD) were evaluated over a period of 30 months. The efficacy of methods followed was checked. Routine beam consistency checks were designed for photon beams with 15 cm/ 5 cm depth ionizations in perspex phantom and variable depth combinations for electron beams. Calculated ionization ratios were compared with measured values to show their significance. The dose/MU for all radiation beams was maintained within 2% accuracy over the period of 30 months. Clinac 600 CD machine showed decreasing trend of cGy/MU, while Clinac 2300 CD showed increasing trend of cGy/MU over a period, which needed tuning of monitor chamber two times each. Tuning of output to achieve standard value was carried out once, for all electron energies when the output dose/MU exceeded 3%. During one week (June 2005), there were slight changes in electron energy detected using the ratio method, which did not recur anytime afterwards. The methods designed are adequate to find the consistency in the beam output and energies in the radiotherapy linacs.
Collapse
|
74
|
Kirthi R, Panchapakesa RC, Kanagarani P, Rukmangatharajan S, Rajeswari S, Ravichandran R, Vasanthy N. P62 Childhood systemic lupus erythematosus: clinical and immunological profile—a Chennai study. INDIAN JOURNAL OF RHEUMATOLOGY 2006. [DOI: 10.1016/s0973-3698(10)60291-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
|
75
|
Vasanthy N, Ravichandran R, Jayalakshmi G, Panchapakesa RC, Rukmangatharajan S, Kanakarani P, Rajeswari S. P63 Clinical and immunological correlation in JIA—Chennai study. INDIAN JOURNAL OF RHEUMATOLOGY 2006. [DOI: 10.1016/s0973-3698(10)60292-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
|