51
|
Summers MP, Parmigiani JP. A water soluble additive to suppress respirable dust from concrete-cutting chainsaws: a case study. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2015; 12:D29-D34. [PMID: 25714034 DOI: 10.1080/15459624.2014.989360] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Respirable dust is of particular concern in the construction industry because it contains crystalline silica. Respirable forms of silica are a severe health threat because they heighten the risk of numerous respirable diseases. Concrete cutting, a common work practice in the construction industry, is a major contributor to dust generation. No studies have been found that focus on the dust suppression of concrete-cutting chainsaws, presumably because, during normal operation water is supplied continuously and copiously to the dust generation points. However, there is a desire to better understand dust creation at low water flow rates. In this case study, a water-soluble surfactant additive was used in the chainsaw's water supply. Cutting was performed on a free-standing concrete wall in a covered outdoor lab with a hand-held, gas-powered, concrete-cutting chainsaw. Air was sampled at the operator's lapel, and around the concrete wall to simulate nearby personnel. Two additive concentrations were tested (2.0% and 0.2%), across a range of fluid flow rates (0.38-3.8 Lpm [0.1-1.0 gpm] at 0.38 Lpm [0.1 gpm] increments). Results indicate that when a lower concentration of additive is used exposure levels increase. However, all exposure levels, once adjusted for 3 hours of continuous cutting in an 8-hour work shift, are below the Occupational Safety and Health Administration (OSHA) permissible exposure limit (PEL) of 5 mg/m(3). Estimates were made using trend lines to predict the fluid flow rates that would cause respirable dust exposure to exceed both the OSHA PEL and the American Conference of Governmental Industrial Hygienists (ACGIH®) threshold limit value (TLV).
Collapse
|
52
|
Anthony TR, Altmaier R, Jones S, Gassman R, Park JH, Peters TM. Use of Recirculating Ventilation With Dust Filtration to Improve Wintertime Air Quality in a Swine Farrowing Room. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2015; 12:635-46. [PMID: 25950713 PMCID: PMC4756717 DOI: 10.1080/15459624.2015.1029616] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
The performance of a recirculating ventilation system with dust filtration was evaluated to determine its effectiveness to improve the air quality in a swine farrowing room of a concentrated animal feeding operation (CAFO). Air was exhausted from the room (0.47 m(3) sec(-1); 1000 cfm), treated with a filtration unit (Shaker-Dust Collector), and returned to the farrowing room to reduce dust concentrations while retaining heat necessary for livestock health. The air quality in the room was assessed over a winter, during which time limited fresh air is traditionally brought into the building. Over the study period, dust concentrations ranged from 0.005-0.31 mg m(-3) (respirable) and 0.17-2.09 mg m(-3) (inhalable). In-room dust concentrations were reduced (41% for respirable and 33% for inhalable) with the system in operation, while gas concentrations (ammonia [NH3], hydrogen sulfide [H2S], carbon monoxide [CO], carbon dioxide [CO2]) were unchanged. The position of the exhaust and return air systems provided reasonably uniform contaminant distributions, although the respirable dust concentrations nearest one of the exhaust ducts was statistically higher than other locations in the room, with differences averaging only 0.05 mg m(-3). Throughout the study, CO2 concentrations consistently exceeded 1540 ppm (industry recommendations) and on eight of the 18 study days it exceeded 2500 ppm (50% of the ACGIH TLV), with significantly higher concentrations near a door to a temperature-controlled hallway that was typically often left open. Alternative heaters are recommended to reduce CO2 concentrations in the room. Contaminant concentrations were modeled using production and environmental factors, with NH3 related to the number of sow in the room and outdoor temperatures and CO2 related to the number of piglets and outdoor temperatures. The recirculating ventilation system provided dust reduction without increasing concentrations of hazardous gases.
Collapse
|
53
|
Ibraev SA, Otarov EZ, Zharylkasyn ZZ, Koigel'dinova SS, Kulov DB, Kalishev MG. [Possiblity to forecast lung pathology via parameters of allowable length of exposure to chrysotile]. MEDITSINA TRUDA I PROMYSHLENNAIA EKOLOGIIA 2015:8-11. [PMID: 26036015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Studies of allowable (safe) length of service in occuptions of mining transport enterprise "Kostanaiskie mineral" JSC were conducted to forecast occurrence of dust lung diseases in workers exposed to chrysotile-asbestos dust. To calculate allowable length of service, the authors used values of average shift concentration of chrysotile-asbestos dust. Based on the calculated data of the allowable length of service in chrysotile-asbestos production, the authors forecasted course of dust lung diseases.
Collapse
|
54
|
Yeoh B, Woolfenden S, Lanphear B, Ridley GF, Livingstone N, Jorgensen E. Household interventions for preventing domestic lead exposure in children. Cochrane Database Syst Rev 2014:CD006047. [PMID: 25506680 DOI: 10.1002/14651858.cd006047.pub4] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
BACKGROUND Lead poisoning is associated with physical, cognitive and neurobehavioural impairment in children and trials have tested many household interventions to prevent lead exposure. This is an update of the original review by the same authors first published in 2008. OBJECTIVES To determine the effectiveness of household interventions in preventing or reducing lead exposure in children as measured by reductions in blood lead levels and/or improvements in cognitive development. SEARCH METHODS We identified trials through electronic searches of CENTRAL (2012, Issue 1), MEDLINE (1948 to January Week 1 2012), EMBASE (1980 to Week 2 2012), CINAHL (1937 to January 2012), PsycINFO (1887 to January Week 2 2012), ERIC (1966 to January 2012), Sociological Abstracts (1952 to January 2012), Science Citation Index (1970 to 20 January 2012), ZETOC (20 January 2012), LILACS (20 January 2012), Dissertation Abstracts (late 1960s to January 2012), ClinicalTrials.gov (19 January 2012), Current Controlled Trials (19 January 2012), Australian New Zealand Clinical Trials Registry (19 January 2012) and the National Research Register Archive. We also contacted experts to find unpublished studies. SELECTION CRITERIA Randomised and quasi-randomised controlled trials of household educational or environmental interventions to prevent lead exposure in children where at least one standardised outcome measure was reported. DATA COLLECTION AND ANALYSIS Two authors independently reviewed all eligible studies for inclusion, assessed risk of bias and extracted data. We contacted trialists to obtain missing information. MAIN RESULTS We included 14 studies (involving 2656 children). All studies reported blood lead level outcomes and none reported on cognitive or neurobehavioural outcomes. We put studies into subgroups according to their intervention type. We performed meta-analysis of both continuous and dichotomous data for subgroups where appropriate. Educational interventions were not effective in reducing blood lead levels (continuous: mean difference (MD) 0.02, 95% confidence interval (CI) -0.09 to 0.12, I(2) = 0 (log transformed); dichotomous ≥ 10µg/dL (≥ 0.48 µmol/L): relative risk (RR) 1.02, 95% CI 0.79 to 1.30, I(2)=0; dichotomous ≥ 15µg/dL (≥ 0.72 µmol/L): RR 0.60, 95% CI 0.33 to 1.09, I(2) = 0). Meta-analysis for the dust control subgroup also found no evidence of effectiveness (continuous: MD -0.15, 95% CI -0.42 to 0.11, I(2) = 0.9 (log transformed); dichotomous ≥ 10µg/dL (≥ 0.48 µmol/L): RR 0.93, 95% CI 0.73 to 1.18, I(2) =0; dichotomous ≥ 15µg/dL (≥ 0.72 µmol/L): RR 0.86, 95% CI 0.35 to 2.07, I(2) = 0.56). When meta-analysis for the dust control subgroup was adjusted for clustering, no statistical significant benefit was incurred. The studies using soil abatement (removal and replacement) and combination intervention groups were not able to be meta-analysed due to substantial differences between studies. AUTHORS' CONCLUSIONS Based on current knowledge, household educational or dust control interventions are ineffective in reducing blood lead levels in children as a population health measure. There is currently insufficient evidence to draw conclusions about the effectiveness of soil abatement or combination interventions.Further trials are required to establish the most effective intervention for prevention of lead exposure. Key elements of these trials should include strategies to reduce multiple sources of lead exposure simultaneously using empirical dust clearance levels. It is also necessary for trials to be carried out in developing countries and in differing socioeconomic groups in developed countries.
Collapse
|
55
|
Shor G. The 1980 OSHA Cotton Dust Standard brochure. New Solut 2014; 24:435-447. [PMID: 25261031 DOI: 10.2190/ns.24.3.l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
|
56
|
Shoemaker D. Vacuuming up to prevent dust explosions. OCCUPATIONAL HEALTH & SAFETY (WACO, TEX.) 2014; 83:27-28. [PMID: 25272916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
|
57
|
He C, Salonen H, Ling X, Crilley L, Jayasundara N, Cheung HC, Hargreaves M, Huygens F, Knibbs LD, Ayoko GA, Morawska L. The impact of flood and post-flood cleaning on airborne microbiological and particle contamination in residential houses. ENVIRONMENT INTERNATIONAL 2014; 69:9-17. [PMID: 24785990 DOI: 10.1016/j.envint.2014.04.001] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/22/2014] [Revised: 03/27/2014] [Accepted: 04/02/2014] [Indexed: 05/26/2023]
Abstract
In January 2011, Brisbane, Australia, experienced a major river flooding event. We aimed to investigate its effects on air quality and assess the role of prompt cleaning activities in reducing the airborne exposure risk. A comprehensive, multi-parameter indoor and outdoor measurement campaign was conducted in 41 residential houses, 2 and 6 months after the flood. The median indoor air concentrations of supermicrometer particle number (PN), PM10, fungi and bacteria 2 months after the flood were comparable to those previously measured in Brisbane. These were 2.88 p cm(-3), 15 μg m(-3), 804 cf um(-3) and 177 cf um(-3) for flood-affected houses (AFH), and 2.74 p cm(-3), 15 μg m(-3), 547 cf um(-3) and 167 cf um(-3) for non-affected houses (NFH), respectively. The I/O (indoor/outdoor) ratios of these pollutants were 1.08, 1.38, 0.74 and 1.76 for AFH and 1.03, 1.32, 0.83 and 2.17 for NFH, respectively. The average of total elements (together with transition metals) in indoor dust was 2296 ± 1328 μg m(-2) for AFH and 1454 ± 678 μg m(-2) for NFH, respectively. In general, the differences between AFH and NFH were not statistically significant, implying the absence of a measureable effect on air quality from the flood. We postulate that this was due to the very swift and effective cleaning of the flooded houses by 60,000 volunteers. Among the various cleaning methods, the use of both detergent and bleach was the most efficient at controlling indoor bacteria. All cleaning methods were equally effective for indoor fungi. This study provides quantitative evidence of the significant impact of immediate post-flood cleaning on mitigating the effects of flooding on indoor bioaerosol contamination and other pollutants.
Collapse
|
58
|
Amato F, Cassee FR, Denier van der Gon HAC, Gehrig R, Gustafsson M, Hafner W, Harrison RM, Jozwicka M, Kelly FJ, Moreno T, Prevot ASH, Schaap M, Sunyer J, Querol X. Urban air quality: the challenge of traffic non-exhaust emissions. JOURNAL OF HAZARDOUS MATERIALS 2014; 275:31-6. [PMID: 24837462 DOI: 10.1016/j.jhazmat.2014.04.053] [Citation(s) in RCA: 142] [Impact Index Per Article: 14.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2014] [Accepted: 04/22/2014] [Indexed: 05/12/2023]
Abstract
About 400,000 premature adult deaths attributable to air pollution occur each year in the European Region. Road transport emissions account for a significant share of this burden. While important technological improvements have been made for reducing particulate matter (PM) emissions from motor exhausts, no actions are currently in place to reduce the non-exhaust part of emissions such as those from brake wear, road wear, tyre wear and road dust resuspension. These "non-exhaust" sources contribute easily as much and often more than the tailpipe exhaust to the ambient air PM concentrations in cities, and their relative contribution to ambient PM is destined to increase in the future, posing obvious research and policy challenges. This review highlights the major and more recent research findings in four complementary fields of research and seeks to identify the current gaps in research and policy with regard to non-exhaust emissions. The objective of this article is to encourage and direct future research towards an improved understanding on the relationship between emissions, concentrations, exposure and health impact and on the effectiveness of potential remediation measures in the urban environment.
Collapse
|
59
|
Fauske A. Combustible dust basics: how to collect a sample and what does a Go/No-Go test mean? OCCUPATIONAL HEALTH & SAFETY (WACO, TEX.) 2014; 83:42-44. [PMID: 24984422] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
|
60
|
Madsen AM, Tendal K, Frederiksen MW. Attempts to reduce exposure to fungi, β-glucan, bacteria, endotoxin and dust in vegetable greenhouses and a packaging unit. THE SCIENCE OF THE TOTAL ENVIRONMENT 2014; 468-469:1112-21. [PMID: 24112965 DOI: 10.1016/j.scitotenv.2013.09.014] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2013] [Revised: 09/04/2013] [Accepted: 09/04/2013] [Indexed: 05/04/2023]
Abstract
Indoor handling of large amounts of plant materials occurs in different occupational settings including greenhouses and causes exposure to bioaerosols. The bioaerosol components fungi, β-glucan, bacteria and endotoxin are involved in different airway symptoms and health effects can be dose-dependent. Therefore, there is a persistent need to reduce exposure. The aims of this study were to identify tasks causing exposure and to evaluate preventive measures aimed at reducing exposure of greenhouse workers to bioaerosols, and to study factors affecting the exposure. We have focused on different exposure scenarios; one with high short-term exposure found during clearing of old cucumber plants; the other with long-term, mid-level exposure found during tomato picking, leaf nipping, stringing up tomato plants, and packaging of cucumbers. Clearing of non-dried cucumber plants compared with clearing of dried cucumber plants significantly reduced the exposure to dust, endotoxin, bacteria, fungal spores and β-glucan. More endotoxin and fungi are emitted and more of the emitted particles were of respirable size if the leaves were dried. Along the cucumber packaging line, exposure levels were highly specific to each personal subtask. The subtask 'unloading of cucumbers' was the source of exposure making task ventilation or shielding of the process a possibility. Elimination of leaf debris on the floor reduced the exposure to fungi significantly. However, leaf debris on the floor did not contribute significantly to the exposure to dust, endotoxin and bacteria. Furthermore, to eliminate leaf debris, it had to be cleared away and this was associated with a higher exposure to dust and endotoxin. The age of the plants affected the exposure level to bioaerosols with higher exposures from old plants. In conclusion, different tasks and subtasks cause very different exposure levels. It is possible to reduce exposure by identifying subtasks causing the exposure and by modifying work processes, e.g., not drying out of plants.
Collapse
|
61
|
Anthony TR, Altmaier R, Park JH, Peters TM. Modeled effectiveness of ventilation with contaminant control devices on indoor air quality in a swine farrowing facility. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2014; 11:434-449. [PMID: 24433305 PMCID: PMC4753560 DOI: 10.1080/15459624.2013.875186] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Because adverse health effects experienced by swine farm workers in concentrated animal feeding operations (CAFOs) have been associated with exposure to dust and gases, efforts to reduce exposures are warranted, particularly in winter seasons when exposures increase due to decreased ventilation. Simulation of air quality and operating costs for ventilating swine CAFO, including treating and recirculating air through a farrowing room, was performed using mass and energy balance equations over a 90-day winter season. System operation required controlling heater operation to achieve room temperatures optimal to ensure animal health (20 to 22.5 °C). Five air pollution control devices, four room ventilation rates, and five recirculation patterns were examined. Inhalable dust concentrations were easily reduced using standard industrial air pollution control devices, including a cyclone, filtration, and electrostatic precipitator. Operating ventilation systems at 0.94 m3 s(-1) (2000 cfm) with 75 to 100% recirculation of treated air from cyclone, electrostatic precipitator, and shaker dust filtration system achieves adequate particle control with operating costs under $1.00 per pig produced ($0.22 to 0.54), although carbon dioxide (CO2) concentrations approach 2000 ppm using in-room ventilated gas fired heaters. In no simulation were CO2 concentrations below industry recommended concentrations (1540 ppm), but alternative heating devices could reduce CO2 to acceptable concentrations. While this investigation does not represent all production swine farrowing barns, which differ in characteristics including room dimensions and swine occupancy, the simulation model and ventilation optimization methods can be applied to other production sites. This work shows that ventilation may be a cost-effective control option in the swine industry to reduce exposures.
Collapse
|
62
|
Garcia A, Jones E, Echt AS, Hall RM. An evaluation of an aftermarket local exhaust ventilation device for suppressing respirable dust and respirable crystalline silica dust from powered saws. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2014; 11:D200-7. [PMID: 25148513 PMCID: PMC4552178 DOI: 10.1080/15459624.2014.955182] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
The objective of this study was to quantify the respirable dust and respirable silica exposures of roofing workers using an electric-powered circular saw with an aftermarket local exhaust ventilation attachment to cut concrete roofing tiles. The study was conducted to determine whether the local exhaust ventilation attachment was able to control respirable dust and respirable silica exposure below occupational exposure limits (OELs). Time-integrated filter samples and direct reading respirable dust concentrations were evaluated. The local exhaust ventilation consisted of a shroud attached to the cutting plane of the saw; the shroud was then connected to a small electric axial fan, which is intended to collect dust at the point of generation. All sampling was conducted with the control in use. Roofers are defined as those individuals who only lay tiles. Cutters/roofers are defined as those workers who operate the powered saw to cut tiles and also lay tiles. Respirable dust from this evaluation ranged from 0.13 to 6.59 milligrams per cubic meter (mg/m(3)) with a geometric mean of 0.38 mg/m(3) for roofers and from 0.45 to 3.82 mg/m(3) with a geometric mean of 1.84 mg/m(3) for cutters/roofers. Cutters/roofers usually handle areas close to crevices, edges, or tips of the roof whereas roofers handle areas where complete tiles can be placed. The respirable dust exposures for all cutters/roofers indicated concentrations exceeding the Occupational Safety and Health Administration's (OSHA) permissible exposure limit (PEL) for respirable dust containing silica; it was also exceeded for some of the roofers. The respirable silica concentrations ranged from 0.04 to 0.15 mg/m(3) with a geometric mean of 0.09 mg/m(3) for roofers, and from 0.13 to 1.21 mg/m(3) with a geometric mean of 0.48 mg/m(3) for cutters/roofers. As with respirable dust, the respirable silica exposures for cutters/roofers were higher than the exposures for roofers.
Collapse
|
63
|
Portnoy J, Miller JD, Williams PB, Chew GL, Miller JD, Zaitoun F, Phipatanakul W, Kennedy K, Barnes C, Grimes C, Larenas-Linnemann D, Sublett J, Bernstein D, Blessing-Moore J, Khan D, Lang D, Nicklas R, Oppenheimer J, Randolph C, Schuller D, Spector S, Tilles SA, Wallace D. Environmental assessment and exposure control of dust mites: a practice parameter. Ann Allergy Asthma Immunol 2013; 111:465-507. [PMID: 24267359 PMCID: PMC5156485 DOI: 10.1016/j.anai.2013.09.018] [Citation(s) in RCA: 91] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2013] [Accepted: 09/20/2013] [Indexed: 12/15/2022]
|
64
|
Yu M, Jiang ZQ, Chen JQ, Zhang X. [Nanoparticle exposure assessment and control in workplace]. ZHONGHUA LAO DONG WEI SHENG ZHI YE BING ZA ZHI = ZHONGHUA LAODONG WEISHENG ZHIYEBING ZAZHI = CHINESE JOURNAL OF INDUSTRIAL HYGIENE AND OCCUPATIONAL DISEASES 2013; 31:715-719. [PMID: 24064138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
|
65
|
Blando JD, Antoine N, Lefkowitz D. Lead-based paint awareness, work practices, and compliance during residential construction and renovation. JOURNAL OF ENVIRONMENTAL HEALTH 2013; 75:20-51. [PMID: 23734528] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
The U.S. Environmental Protection Agency recently implemented the Renovation, Repair and Painting (RRP) rule that applies to pre-1978 residences because of the potential presence of lead-based paint. Enforcement of this rule may be difficult and therefore it is crucial to understand the awareness and beliefs of contractors and the general public because these will likely be major determinants of exposures resulting from residential renovation work. The study described in this article utilized two mailed surveys: one directed to the general public and the other directed to contractors. The surveys were conducted in New Jersey and Virginia. Field observations were also recorded for work sites in New Jersey. Results indicated a high awareness among the general public about the hazards of lead, a low level of screening by children's doctors for lead exposure, frequent use of work practices that generate lots of dust, poor hygiene among contractors, and the potential for low compliance of contractors with the RRP rule. In particular, contractors who do not believe lead is a serious health hazard are expected to have the lowest compliance with the RRP rule. These findings serve as targets for effective public health interventions through education and outreach.
Collapse
|
66
|
Luzik SJ. NFPA 654 2013 edition revised requirements for housekeeping. OCCUPATIONAL HEALTH & SAFETY (WACO, TEX.) 2013; 82:38-40. [PMID: 23556256] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
|
67
|
Shepherd S, Woskie S. Controlling dust from concrete saw cutting. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2013; 10:64-70. [PMID: 23252479 DOI: 10.1080/15459624.2012.747129] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Cutting concrete with gas-powered saws is ubiquitous in the construction industry and a source of exposure to respirable crystalline silica. Volunteers from the New England Laborers Training Center were recruited to participate in a field experiment examining dust reductions through the use of water, from a hose and from a sprayer, as a dust control. In four series of tests, reinforced concrete pipe was cut under both "dry" and "wet" control conditions. Overall, the geometric mean respirable dust concentration for "dry" cutting (14.396 mg/m³) exceeded both types of water-based controls by more than tenfold. Wet cutting reduced the respirable dust concentration by 85% compared with dry cutting when comparing tests paired by person and saw blade (n = 79 pairs). Using a respirable cyclone, a total of 178 samples were taken. Due to the high variability in dust exposure found in this and other studies of saw cutting, the data were examined for potential exposure determinants that contribute to that variability. Using mixed models, three fixed effects were statistically significant: control condition, worker experience, and location. A random effect for subject was included in the model to account for repeated measures. When each of the significant fixed effects was included with the random effect, it was apparent that inclusion of worker experience or location reduced the between-worker component of exposure variability, while inclusion of control condition (wet vs. dry) explained a large portion of the within-subject variability. Overall, the fixed effect variable for control condition explained the largest fraction of the total exposure variability.
Collapse
|
68
|
Zheng W, Li B, Cao W, Zhang G, Yang Z. Application of neutral electrolyzed water spray for reducing dust levels in a layer breeding house. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION (1995) 2012; 62:1329-1334. [PMID: 23210224 DOI: 10.1080/10962247.2012.710553] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Reducing airborne dust is an essential process for improving hen housing environment. Dust reduction effects of neutral electrolyzed water (pH 8.2) spray were investigated in a commercial tunnel-ventilated layer breeding house during production in northern China. A multipoint sampler was used to measure airborne dust concentration to study the dust reduction effects and distribution in the house. Compared with the control treatment (without spray), airborne dust level was reduced 34% in the 3 hr after spraying 216 mL m(-2) neutral electrolyzed water in the breeding house. The dust concentration was significantly higher during the periods of feed distribution (1.13 +/- 0.13 mg m(-3)) and artificial insemination (0.72 +/- 0.13 mg m(-3)) compared with after spray (0.47 +/- 0.09 mg m(-3)) and during lights-off period (0.29 +/- 0.08 mg m(-3)) in the three consecutive testing days (P <0.05). The experimental cage area was divided into four zones along the length of the house, with zone 1 nearest to the evaporative cooling pad and zone 4 nearest to the fans. The air temperature, relative humidity, airflow rate, and dust concentration were measured at the sampling points of the four zones in 3 consecutive days and mortality of the birds for the duration of a month were investigated. The results showed that the air temperature, airflow rate, dust concentration, and number of dead birds increase from zone 1 to zone 4 in the tunnel-ventilated layer breeding house.
Collapse
|
69
|
El-Ghitany EM, Abd El-Salam MM. Environmental intervention for house dust mite control in childhood bronchial asthma. Environ Health Prev Med 2012; 17:377-84. [PMID: 22302565 PMCID: PMC3437361 DOI: 10.1007/s12199-011-0263-5] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2011] [Accepted: 12/29/2011] [Indexed: 11/29/2022] Open
Abstract
OBJECTIVES This study was carried out to determine the effectiveness of physical and chemical environmental control measures for house dust mites (HDM) in controlling bronchial asthma in children. METHODS A total of 160 asthmatic children who were sensitized to HDM underwent clinical and environmental assessment. The children were randomly allocated into one of four groups according to the intervention (chemical, physical, both chemical and physical, none) and the effectiveness of the intervention was assessed at 8 and 16 weeks. RESULTS The group for which physical control measures were used showed significant improvement in all outcome measures, including mean differences of forced expiratory volume after 1 s (FEV1) and peak expiratory flow rate (PEFR), which were 2.05% and 4.65 l/min, respectively, at the 8-week follow-up evaluation. The percentage of severe asthma decreased from 45 to 22%. Similar results were obtained for the group with both chemical (tannic acid) and physical interventions (p < 0.05 for all measures). In the group where tannic acid was used as a chemical measure, the number of children with moderate and severe asthma decreased from 15 in each category to 11 and 7, respectively. In the control group, only the mean difference of PEFR (1.62 l/min) was significant after 16 weeks. Despite these promising findings, only the FEV1 was significantly different (p = 0.014) when the four groups were compared. CONCLUSIONS Based on these results, we conclude that simple physical control measures have the potential to contribute to the control of asthma symptoms in asthmatic children sensitized to HDM allergen.
Collapse
|
70
|
Holman C. The health impact of demolition dust. HEALTH ESTATE 2012; 66:72-74. [PMID: 23009022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Dr Claire Holman, Principal at ENVIRON, a global consultancy which works with clients 'to manage their most challenging environmental and health and safety issues, and attain their sustainability goals', considers the impacts on health of dust released during demolition work, and the measures that can be taken to mitigate them. Drawing on a recent case study, she explains how ENVIRON prepared a comprehensive site dust management plan (DMP) to minimise fungal spore release during the demolition of a building located adjacent to residential accommodation for child leukaemia patients and their parents. She also considers some of the lessons learned, in terms of actions that 'worked well' and those that could, with hindsight, have been undertaken 'better'.
Collapse
|
71
|
Liu L, Guan D, Peart MR. The morphological structure of leaves and the dust-retaining capability of afforested plants in urban Guangzhou, South China. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2012; 19:3440-3449. [PMID: 22614051 DOI: 10.1007/s11356-012-0876-2] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2011] [Accepted: 03/13/2012] [Indexed: 06/01/2023]
Abstract
PURPOSE Air pollution is a serious health problem throughout the world, exacerbating a wide range of respiratory and vascular illnesses in urban areas. The mass artificial plantation is very helpful to absorb dust and reduce pollution for conservation of the urban environment. The foliar surface of plants is an important receptor of atmospheric pollutants. Therefore, selection of suitable plant species for urban environment is very important. METHODS The dust-retaining capability of urban trees in Guangzhou was determined at four different types of urban area, and the morphological traits of their leaves such as wax, cuticle, stomata, and trichomes were observed under a scanning electron microscope. RESULTS It was determined that the dust-retaining capability of any given tree species is significantly different in the same place. Of the four studied tree species in the industrial area (IA) and commercial/traffic areas (CTA) type urban areas, the highest amounts of dust removed by Mangifera indica Linn was 12.723 and 1.482 g/m(2), respectively. However, in contrast, the equivalent maxima for Bauhinia blakeana is only 2.682 g/m(2) and 0.720 g/m(2), respectively. Different plant species have different leaf morphology. The leaf of M. indica has deep grooves and high stomata density which are in favor of dust-retained, and thus, their dust-retained capability is stronger, while B. blakeana has the cells and epicuticular wax with its stomata arranging regularly, resulting in poor dust catching capability. Leaf size was also shown to be related to dust capture for the four studied tree species. CONCLUSIONS The dust removal capacity of individual tree species should be taken into account in the management of greening plantation in and around an urban area. It was also shown that temporal variation in dust accumulation occurred over the 28-day observation period and this was discussed. Furthermore, spatial contrasts in dust accumulation were evidenced by the data. This reflected the differing pollution loadings of the four urban-type areas. The highest amount of dust accumulation was associated with the industrial area in which shipyard and steelworks occurred whilst the lowest dust accumulation was associated with the grounds of the University which was the control area.
Collapse
|
72
|
DeLuca PF, Corr D, Wallace J, Kanaroglou P. Effective mitigation efforts to reduce road dust near industrial sites: assessment by mobile pollution surveys. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2012; 98:112-118. [PMID: 22265811 DOI: 10.1016/j.jenvman.2011.12.023] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2010] [Revised: 11/30/2011] [Accepted: 12/26/2011] [Indexed: 05/31/2023]
Abstract
Assessment of spatial variation of fugitive dust sources, particularly road dust track-out from industrial sites and its subsequent re-suspension is difficult with fixed air quality monitoring stations given their sparse distribution and the highly localized nature of road dust. Mobile monitoring was employed to measure levels of road dust in the industrial area of the City of Hamilton, Ontario, Canada. Results of this monitoring were used in a Fugitive Dust Control workshop held for local stakeholders, where fugitive dust control solutions were presented. After the workshop, the City of Hamilton and cooperative industrial groups executed enhanced street cleaning and individual industries and facilities performed on-site control activities. Post-workshop mobile air monitoring was performed for comparison to the initial values to determine effectiveness of these approaches. A regression model testing the difference pre- and post-workshop yielded a statistically significant difference in PM(10) measurements demonstrating improvement. The average value of PM(10) prior to the workshop was 114 μg/m(3). Post-workshop the average value dropped to 73 μg/m(3).
Collapse
|
73
|
Yeoh B, Woolfenden S, Lanphear B, Ridley GF, Livingstone N. Household interventions for preventing domestic lead exposure in children. Cochrane Database Syst Rev 2012:CD006047. [PMID: 22513934 DOI: 10.1002/14651858.cd006047.pub3] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND Lead poisoning is associated with physical, cognitive and neurobehavioural impairment in children and trials have tested many household interventions to prevent lead exposure. This is an update of the original review by the same authors first published in 2008. OBJECTIVES To determine the effectiveness of household interventions in preventing or reducing lead exposure in children as measured by reductions in blood lead levels and/or improvements in cognitive development. SEARCH METHODS We identified trials through electronic searches of CENTRAL (The Cochrane Library, 2010, Issue 2), MEDLINE (1948 to April Week 1 2012), EMBASE (1980 to 2012 Week 2), CINAHL (1937 to 20 Jan 2012), PsycINFO (1887 to Dec week 2 2011), ERIC (1966 to 17 Jan 2012), Sociological Abstracts (1952 to 20 January 2012), Science Citation Index (1970 to 20 Jan 2012), ZETOC (20 Jan 2012), LILACS (20 Jan 2012), Dissertation Abstracts (late 1960s to Jan 2012), ClinicalTrials.gov (20 Jan 2012), Current Controlled Trials (Jan 2012), Australian New Zealand Clinical Trials Registry (Jan 2012) and the National Research Register Archive. We also contacted experts to find unpublished studies. SELECTION CRITERIA Randomised and quasi-randomised controlled trials of household educational or environmental interventions to prevent lead exposure in children where at least one standardised outcome measure was reported. DATA COLLECTION AND ANALYSIS Two authors independently reviewed all eligible studies for inclusion, assessed risk of bias and extracted data. We contacted trialists to obtain missing information. MAIN RESULTS We included 14 studies (involving 2656 children). All studies reported blood lead level outcomes and none reported on cognitive or neurobehavioural outcomes. We put studies into subgroups according to their intervention type. We performed meta-analysis of both continuous and dichotomous data for subgroups where appropriate. Educational interventions were not effective in reducing blood lead levels (continuous: mean difference (MD) 0.02, 95% confidence interval (CI) -0.09 to 0.12, I(2) = 0 (log transformed); dichotomous ≥ 10µg/dL (≥ 0.48 µmol/L): relative risk (RR) 1.02, 95% CI 0.79 to 1.30, I(2)=0; dichotomous ≥ 15µg/dL (≥ 0.72 µmol/L): RR 0.60, 95% CI 0.33 to 1.09, I(2) = 0). Meta-analysis for the dust control subgroup also found no evidence of effectiveness (continuous: MD -0.15, 95% CI -0.42 to 0.11, I(2) = 0.9 (log transformed); dichotomous ≥ 10µg/dL (≥ 0.48 µmol/L): RR 0.93, 95% CI 0.73 to 1.18, I(2) =0; dichotomous ≥ 15µg/dL (≥ 0.72 µmol/L): RR 0.86, 95% CI 0.35 to 2.07, I(2) = 0.56). When meta-analysis for the dust control subgroup was adjusted for clustering, no statistical significant benefit was incurred. The studies using soil abatement (removal and replacement) and combination intervention groups were not able to be meta-analysed due to substantial differences between studies. AUTHORS' CONCLUSIONS Based on current knowledge, household educational or dust control interventions are ineffective in reducing blood lead levels in children as a population health measure. There is currently insufficient evidence to draw conclusions about the effectiveness of soil abatement or combination interventions.Further trials are required to establish the most effective intervention for prevention of lead exposure. Key elements of these trials should include strategies to reduce multiple sources of lead exposure simultaneously using empirical dust clearance levels. It is also necessary for trials to be carried out in developing countries and in differing socioeconomic groups in developed countries.
Collapse
|
74
|
Séguin V, Garon D, Lemauviel-Lavenant S, Lanier C, Bouchart V, Gallard Y, Blanchet B, Diquélou S, Personeni E, Ourry A. How to improve the hygienic quality of forages for horse feeding. JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE 2012; 92:975-986. [PMID: 22002664 DOI: 10.1002/jsfa.4680] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/20/2011] [Revised: 07/22/2011] [Accepted: 08/23/2011] [Indexed: 05/31/2023]
Abstract
BACKGROUND Improving the hygienic quality of forages for horse nutrition seems to be a reasonable target for decreasing the prevalence of pulmonary diseases. The aim of the experiment was to study the effects of different agricultural practices on the main aero-allergens contained in forages, including breathable dust, fungi, mycotoxins and pollens. RESULTS Results showed that the late harvest of hay, a second crop or a haylage production provides a good alternative to increase hygienic quality by reducing fungi contamination and breathable dust content. Barn drying of hay, while having no effect on breathable dust, similarly reduced fungi contamination. In contrast, when hay was harvested at a lower dry mass content (750 g DM kg⁻¹ versus 850 g DM kg⁻¹), both breathable dust and fungi contaminations were increased, which could at least be reversed by adding propionic acid just before baling. Zearalenone was detected in different hays, and even in one case, in breathable dust. CONCLUSION Overall, our data suggest that different approaches can be used to increase forage hygienic quality for horse feeding and thus reduce their exposure to factors involved in equine pulmonary disease.
Collapse
|
75
|
Phillips ML, Johnson AC. Prevalence of dry methods in granite countertop fabrication in Oklahoma. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2012; 9:437-442. [PMID: 22650974 DOI: 10.1080/15459624.2012.684549] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Granite countertop fabricators are at risk of exposure to respirable crystalline silica, which may cause silicosis and other lung conditions. The purpose of this study was to estimate the prevalence of exposure control methods, especially wet methods, in granite countertop fabrication in Oklahoma to assess how many workers might be at risk of overexposure to crystalline silica in this industry. Granite fabrication shops in the three largest metropolitan areas in Oklahoma were enumerated, and 47 of the 52 shops participated in a survey on fabrication methods. Countertop shops were small businesses with average work forces of fewer than 10 employees. Ten shops (21%) reported using exclusively wet methods during all fabrication steps. Thirty-five shops (74%) employing a total of about 200 workers reported using dry methods all or most of the time in at least one fabrication step. The tasks most often performed dry were edge profiling (17% of shops), cutting of grooves for reinforcing rods (62% of shops), and cutting of sink openings (45% of shops). All shops reported providing either half-face or full-face respirators for use during fabrication, but none reported doing respirator fit testing. Few shops reported using any kind of dust collection system. These findings suggest that current consumer demand for granite countertops is giving rise to a new wave of workers at risk of silicosis due to potential overexposure to granite dust.
Collapse
|