51
|
Radi IA. OCCLUSAL APPLIANCES MIGHT BE CLINICALLY EFFICIENT IN TREATING SLEEP BRUXISM. J Evid Based Dent Pract 2023; 23:101890. [PMID: 37689458 DOI: 10.1016/j.jebdp.2023.101890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/11/2023]
Abstract
ARTICLE TITLE AND BIBLIOGRAPHIC INFORMATION Minakuchi H, Fujisawa M, Abe Y, Iida T, Oki K, Okura K, Tanabe N, Nishiyama A. Managements of sleep bruxism in adult: A systematic review. Jpn Dent Sci Rev. 2022; 58:124-36. SOURCE OF FUNDING None was reported. TYPE OF STUDY/DESIGN Systematic review.
Collapse
|
52
|
Malenova Y, Ortner F, Liokatis P, Haidari S, Tröltzsch M, Fegg F, Obermeier KT, Hartung JT, Kakoschke TK, Burian E, Otto S, Sabbagh H, Probst FA. Accuracy of maxillary positioning using computer-designed and manufactured occlusal splints or patient-specific implants in orthognathic surgery. Clin Oral Investig 2023; 27:5063-5072. [PMID: 37382718 PMCID: PMC10492762 DOI: 10.1007/s00784-023-05125-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2023] [Accepted: 06/20/2023] [Indexed: 06/30/2023]
Abstract
OBJECTIVE To determine the accuracy of maxillary positioning using computer-designed and manufactured occlusal splints or patient-specific implants in orthognathic surgery. MATERIAL AND METHODS A retrospective analysis of 28 patients that underwent virtually planned orthognathic surgery with maxillary Le Fort I osteotomy either using VSP-generated splints (n = 13) or patient-specific implants (PSI) (n = 15) was conducted. The accuracy and surgical outcome of both techniques were compared by superimposing preoperative surgical planning with postoperative CT scans and measurement of translational and rotational deviation for each patient. RESULTS The 3D global geometric deviation between the planned position and the postoperative outcome was 0.60 mm (95%-CI 0.46-0.74, range 0.32-1.11 mm) for patients with PSI and 0.86 mm (95%-CI 0.44-1.28, range 0.09-2.60 mm) for patients with surgical splints. Postoperative differences for absolute and signed single linear deviations between planned and postoperative position were a little higher regarding the x-axis and pitch but lower regarding the y- and z-axis as well as yaw and roll for PSI compared to surgical splints. There were no significant differences regarding global geometric deviation, absolute and signed linear deviations in the x-, y-, and z-axis, and rotations (yaw, pitch, and roll) between both groups. CONCLUSIONS Regarding accuracy for positioning of maxillary segments after Le Fort I osteotomy in orthognathic surgery patient-specific implants and surgical splints provide equivalent high accuracy. CLINICAL RELEVANCE Patient-specific implants for maxillary positioning and fixation facilitate the concept of splintless orthognathic surgery and can be reliably used in clinical routines.
Collapse
|
53
|
Wu B, Lv K. Control of Mandibular Width With 3D Printed Occlusal Splint in Children With Multiple Mandibular Fractures. J Craniofac Surg 2023; 34:e582-e584. [PMID: 37236625 DOI: 10.1097/scs.0000000000009418] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Accepted: 03/28/2023] [Indexed: 05/28/2023] Open
Abstract
BACKGROUND The fracture of mandibular symphysis combined with bilateral condylar fractures often leads to changes in the width of the mandible, which significantly widens the face of the child. Therefore, it is necessary to reposition the mandible through accurate adduction. METHODS To ensure that the mandible can be accurately repositioned, a 3D printed occlusal splint was used. Bilateral maxillomandibular fixation screws were implanted. The 3D printed occlusal splint was located on the maxillary dentition and fixed to the maxillomandibular fixation screws with wire loops. The reference basis for adduction is to make the mandibular dentition located in the occlusal splint. The absorbable plate was contoured according to the restored model and fixed at the fracture site. The 3D printed occlusal splint was retained in the maxillary dentition for two months. RESULTS AND DISCUSSION Postoperative computed tomography showed that the mandible had been adducted according to the preoperative design. Two months of follow-up showed that the child's facial development, mouth opening type, occlusion, and range of motion were good. It is especially suitable for children with mandibular symphyseal fractures accompanied by bilateral condylar fractures.
Collapse
|
54
|
O'Toole S, Moazzez R, Wojewodka G, Zeki S, Jafari J, Hope K, Brand A, Hoare Z, Scott S, Doungsong K, Ezeofor V, Edwards RT, Drakatos P, Steier J. Single-centre, single-blinded, randomised, parallel group, feasibility study protocol investigating if mandibular advancement device treatment for obstructive sleep apnoea can reduce nocturnal gastro-oesophageal reflux (MAD-Reflux trial). BMJ Open 2023; 13:e076661. [PMID: 37620257 PMCID: PMC10450077 DOI: 10.1136/bmjopen-2023-076661] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Accepted: 08/16/2023] [Indexed: 08/26/2023] Open
Abstract
INTRODUCTION Just under half of patients with obstructive sleep apnoea (OSA) also have gastro-oesophageal reflux disease (GORD). These conditions appear to be inter-related and continual positive airway pressure (CPAP) therapy, the gold standard treatment for OSA to prevent airway collapse, has been shown to reduce GORD. As the impact of mandibular advancement devices, a second-line therapy for OSA, on GORD has yet to be investigated, a feasibility study is needed prior to a definitive trial. METHODS This will be a single-centre, single-blinded, tertiary-care based, interdisciplinary, parallel randomised controlled study. Potential OSA participants presenting to the sleep department will be pre-screened for GORD using validated questionnaires, consented and invited to receive simultaneous home sleep and oesophageal pH monitoring. Those with confirmed OSA and GORD (n=44) will be randomly allocated to receive either CPAP (n=22) or MAD therapy (n=22). Following successful titration and 3 weeks customisation period, participants will repeat the simultaneous sleep and oesophageal pH monitoring while wearing the device. The number of patients screened for recruitment, drop-out rates, patient feedback of the study protocol, costs of interventions and clinical information to inform a definitive study design will be investigated. ETHICS AND DISSEMINATION Health Research Authority approval has been obtained from the Nottingham 2 Research Ethics Committee, ref:22/EM/0157 and the trial has been registered on ISRCTN (https://doi.org/10.1186/ISRCTN16013232). Definitive findings about the feasibility of doing 24 hour pH oesophageal monitoring while doing a home sleep study will be disseminated via clinical and research networks facilitating valuable insights into the simultaneous management of both conditions. TRIAL REGISTRATION NUMBER ISRCTN Reg No: 16013232.
Collapse
|
55
|
Iftikhar IH, Cistulli PA, Jahrami H, Alamoud KA, Saeed M, Soulimiotis AP, BaHammam AS. Comparative efficacy of mandibular advancement devices in obstructive sleep apnea: a network meta-analysis. Sleep Breath 2023; 27:1365-1381. [PMID: 36374442 DOI: 10.1007/s11325-022-02744-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Revised: 10/25/2022] [Accepted: 11/05/2022] [Indexed: 11/16/2022]
Abstract
PURPOSE To analyze relative efficacies of mandibular advancement devices (MAD) in sleep apnea treatment. METHODS From eligible randomized controlled trials (RCT), MADs were classified based on their mechanistic designs. Data on apnea-hypopnea index (AHI), Epworth sleepiness scale (ESS), nadir oxygen saturation (minSaO2), and sleep efficiency (SE%) from RCTs were then analyzed in network meta-analyses, and relative ranking of different MADs was computed based on P scores (a method of ranking similar to SUCRA). Similar analyses were conducted based on the different brands of MADs. RESULTS There were no statistically significant differences between MADs in any of the outcomes analyzed. However, the P-scores, based on the point estimates and standard errors of the network estimates, ranked some MADs higher than others in some of the outcomes. Of the different mechanistic designs, the highest P scores were achieved for attached midline traction (P score = 0.84) and unattached bilateral interlocking (P score = 0.78) devices for AHI reduction, attached bilateral traction (P score = 0.78) and unattached bilateral interlocking (P score = 0.76) for ESS, monobloc (P score = 0.91) and unattached bilateral interlocking (P score = 0.64) for minSaO2, and unattached bilateral interlocking (P score = 0.82) and attached bilateral traction (P score = 0.77) for SE%. Notable findings in the network meta-analyses based on MAD brands, of the limited number of studies that specified them were the effects of SomnoDent Flex™, TAP™, and IST® in their effects on AHI reduction, with P scores of 0.94, 0.83, and 0.82, respectively. Monobloc decreased supine-AHI the most (- 44.46 [- 62.55; - 26.36], P score = 0.99), and unattached bilateral interlocking had the greatest effect on REM-AHI (- 11.10 [- 17.10; - 5.10], P score = 0.87). CONCLUSIONS Findings from this study show clinically (but not statistically) significant differences between MADs in terms of their relative efficacy when analyzed for different sleep apnea treatment outcomes and sleep apnea phenotypes.
Collapse
|
56
|
Sangalli L, Yanez-Regonesi F, Fernandez-Vial D, Moreno-Hay I. Self-reported improvement in obstructive sleep apnea symptoms compared to treatment response with mandibular advancement device therapy: a retrospective study. Sleep Breath 2023; 27:1577-1588. [PMID: 36449217 DOI: 10.1007/s11325-022-02754-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 11/09/2022] [Accepted: 11/21/2022] [Indexed: 12/02/2022]
Abstract
PURPOSE Mandibular advancement device (MAD) is recognized as the treatment option for management of obstructive sleep apnea (OSA) in mild-moderate cases or those unable to tolerate positive airway pressure therapy. Post-treatment sleep study is recommended to establish MAD efficacy when maximal therapeutic benefit is achieved based on OSA symptom improvement or maximum anatomical protrusion. The aim of this study was to investigate the difference between responders and non-responders in OSA symptom improvement and predictors of treatment success. METHODS Medical charts of patients referred to the Orofacial Pain Clinic between 2016 and 2021 for management of OSA with MAD were retrospectively evaluated. Participants with post-treatment sleep study with MAD in situ were included. Participants were categorized as responders according to different criteria: 50% reduction in apnea-hypopnea index (AHI) compared to baseline; post-treatment AHI ≤ 10 with ≥ 50% reduction from baseline; AHI ≤ 5 with ≥ 50% reduction. OSA symptoms included snoring, apneas, sleep quality, tiredness upon awakening, daytime sleepiness, and subjective improvement. Differences in pre- and post-treatment variables within/between groups and predictors were analyzed with t test and logistic regression. RESULTS Among 53 participants (30 females), mean age was 64.2 ± 10.7 and pre-treatment was AHI 23.3 ± 17.2. Depending upon the criteria, responders ranged between 26 and 57%. At first follow-up after MAD delivery, non-responders reported less tiredness upon awakening (p = 0.003), better sleep quality (p = 0.005), and greater subjective improvement (p = 0.012) than responders. Among significant OSA symptoms, tiredness upon awakening, poorer sleep quality, and less subjective improvement were consistently found as predictors of treatment response. CONCLUSION Subjective improvement, sleep quality, and tiredness upon awakening significantly improved in non-responders at first follow-up compared to responders, according to the strictest definition of treatment response. Therefore, a post-treatment sleep study is crucial to confirm proper management of OSA with MAD.
Collapse
|
57
|
Zhiguo Z, Ruizhi T, Fan Z, Wenchao S, Maoning W. Biomechanical effects of a mandibular advancement device on the periodontal ligament: Based on different bone models. J Mech Behav Biomed Mater 2023; 144:105914. [PMID: 37290168 DOI: 10.1016/j.jmbbm.2023.105914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 05/13/2023] [Accepted: 05/15/2023] [Indexed: 06/10/2023]
Abstract
Obstructive sleep apnea syndrome (OSAS) is recurrent apnoea caused by upper airway obstruction during sleep. In severe cases, OSAS might lead to sudden death. Currently, the mandibular advancement device (MAD) is the preferred product for the treatment of mild to moderate OSAS because of its compliance, portability and low cost. However, many clinical studies have suggested that long-term use of MAD might cause occlusal changes, periodontitis, muscle soreness, and joint damage. In view of the difficulties in the measurement of relevant mechanical factors in vivo, the present work aimed to quantitatively analyze biomechanical mechanisms that might lead to these side effects through computer numerical simulations and a nonhomogeneous alveolar bone model was established to approximate the actual bony features of the jaw in the simulations model. First, a 3D digital model of the teeth, periodontal ligament(PDL), and alveolar bone was created on the basis of computed tomography images and assembled with a 3D model of the MAD. A nonhomogeneous alveolar bone model was created based on computed tomographic images, and the stresses acting on the PDL were computed using the finite element method. The results showed that the nonhomogeneous model could more realistically reflect the mechanical properties of the alveolar bone and obtain the true stresses compared with the homogeneous model, which underestimated the adverse effects of PDL therapy. The numerical simulations in this paper can help doctors make more accurate judgements about MAD treatment from an oral health protection perspective.
Collapse
|
58
|
Benli M, Özcan M. Short-term effect of material type and thickness of occlusal splints on maximum bite force and sleep quality in patients with sleep bruxism: a randomized controlled clinical trial. Clin Oral Investig 2023; 27:4313-4322. [PMID: 37127807 DOI: 10.1007/s00784-023-05049-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2022] [Accepted: 04/26/2023] [Indexed: 05/03/2023]
Abstract
OBJECTIVE To evaluate the short-term effects of hard and soft splints of different thicknesses on maximum bite force (MBF) and sleep quality (SQ) in participants with sleep bruxism (SB). METHODS One-hundred-fifteen patients were randomly allocated to five groups: Groups H2(Hard splint-2 mm), H3(Hard splint-3 mm), S2(Soft splint-2 mm), S3(Soft splint-3 mm), and C (control). Outcomes were MBF (assessed with a digital gnathodynamometer) and SQ (assessed with the Pittsburgh Sleep Quality Index). Measurements were performed at T0 (before the splints), T1 (1-month follow-up), and T2 (2-months follow-up). Data were analyzed using one-way analysis of variance(ANOVA), Tukey's HSD, and chi-square tests (alpha = 0.05). RESULTS At T1, the highest MBF values were observed in group H3 (658.01 ± 22.6 N), while the lowest in group S2 (585.45 ± 8.68 N). For T2, the highest values were obtained in H3 group (676.85 ± 21.9 N), and the lowest in group S2 (565.65 ± 10.9 N) (p < 0.05).For SQ, groups S2 and S3 revealed the lowest PSQI values at T1 (9.1; 9.6) and T2 (9; 9.5) (p < 0.001). CONCLUSIONS The short-term use of both 2 and 3-mm thick soft splints resulted in a decrease in MBF. Improvement in SQ in patients using soft splints was observed in the 1st month and was maintained in the 2nd month. CLINICAL RELEVANCE This study provides insights on short-term clinical effects as regards to increased sleep quality and regulated maximum bite force as a function of splint material type and the thickness of the splint.
Collapse
|
59
|
Gurgel M, Cevidanes L, Costa F, Pereira R, Cunali P, Bittencourt L, Ruellas A, Gonçalves J, Bianchi J, Chaves C. Three-dimensional comparison between the effects of mandibular advancement device and maxillomandibular advancement surgery on upper airway. BMC Oral Health 2023; 23:436. [PMID: 37391785 PMCID: PMC10314553 DOI: 10.1186/s12903-023-03125-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Accepted: 06/10/2023] [Indexed: 07/02/2023] Open
Abstract
BACKGROUND The efficacy of mandibular advancement devices (MAD) and maxillomandibular advancement (MMA) in improving upper airway (UA) patency has been described as being comparable to continuous positive airway pressure (CPAP) outcomes. However, no previous study has compared MAD and MMA treatment outcomes for the upper airway enlargement. This study aimed to evaluate three-dimensionally the UA changes and mandibular rotation in patients after MAD compared to MMA. METHODS The sample consisted of 17 patients with treated with MAD and 17 patients treated with MMA matched by weight, height, body mass index. Cone-beam computed tomography from before and after both treatments were used to measure total UA, superior/inferior oropharynx volume and surface area; and mandibular rotation. RESULTS Both groups showed a significant increase in the superior oropharynx volume after the treatments (p = 0.003) and the MMA group showed greater increase (p = 0.010). No statistical difference was identified in the MAD group considering the inferior volume, while the MMA group showed a significantly gain (p = 0.010) and greater volume (p = 0.024). Both groups showed anterior mandibular displacement. However, the mandibular rotation were statistically different between the groups (p < 0.001). While the MAD group showed a clockwise rotation pattern (-3.97 ± 1.07 and - 4.08 ± 1.30), the MMA group demonstrated a counterclockwise (2.40 ± 3.43 and 3.41 ± 2.79). In the MAD group, the mandibular linear anterior displacement was correlated with superior [p = 0.002 (r=-0.697)] and inferior [p = 0.004 (r = 0.658)] oropharynx volume, suggesting that greater amounts of mandibular advancement are correlated to a decrease in the superior oropharynx and an increase in the inferior oropharynx. In the MMA group, the superior oropharynx volume was correlated to mandibular anteroposterior [p = 0.029 (r=-0.530)] and vertical displacement [p = 0.047 (r = 0.488)], indicating greater amounts of mandibular advancement may lead to a lowest gain in the superior oropharynx volume, while a great mandibular superior displacement is correlated with improvements in this region. CONCLUSIONS The MAD therapy led to a clockwise mandibular rotation, increasing the dimensions of the superior oropharynx; while a counterclockwise rotation with greater increases in all UA regions were showed in the MMA treatment.
Collapse
|
60
|
Shi X, Lobbezoo F, Chen H, Rosenmöller BRAM, Berkhout E, de Lange J, Aarab G. Comparisons of the effects of two types of titratable mandibular advancement devices on respiratory parameters and upper airway dimensions in patients with obstructive sleep apnea: a randomized controlled trial. Clin Oral Investig 2023; 27:2013-2025. [PMID: 36928350 PMCID: PMC10160211 DOI: 10.1007/s00784-023-04945-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Accepted: 03/06/2023] [Indexed: 03/18/2023]
Abstract
OBJECTIVES To compare the effects of two types of titratable mandibular advancement devices (MADs), namely MAD-H (allowing limited vertical opening) and MAD-S (allowing free vertical opening), on respiratory parameters and upper airway dimensions in patients with mild to moderate obstructive sleep apnea (OSA). MATERIALS AND METHODS Patients with mild to moderate OSA (5 ≤ apnea-hypopnea index (AHI) < 30 /h) were randomly assigned to two parallel MAD groups. All MADs were subjectively titrated according to a standardized protocol during a 3-month follow-up. Every patient underwent two polysomnographic recordings, and two cone beam computed tomography scans in supine position: one at baseline and another one after 3 months with the MAD in situ. The primary outcome variables were the AHI in supine position (AHI-supine) and the minimal cross-sectional area of the upper airway in supine position (CSAmin-supine). RESULTS A total of 49 patients were recruited, and 31 patients (21 men and 10 women) with a mean (± SD) age of 48.5 (± 13.9) years and a mean AHI of 16.6 (± 6.7) /h completed the study. In the per-protocol analysis, there was no significant difference between MAD-H (n = 16) and MAD-S (n = 15) in their effects on AHI-supine (P = 0.14) and CSAmin-supine (P = 0.59). Similar results were found in the intention-to-treat analysis (P = 0.47 and 0.57, respectively). CONCLUSIONS Within the limitations of this study, we conclude that there is no significant difference in the effects of an MAD allowing limited vertical opening and an MAD allowing free vertical opening on respiratory parameters and upper airway dimensions in patients with mild to moderate OSA. CLINICAL RELEVANCE MADs allowing limited vertical opening and allowing free vertical opening have similar effects on respiratory parameters and upper airway dimensions in patients with mild to moderate OSA. TRIAL REGISTRATION ClinicalTrials.gov Identifier: NCT02724865. https://clinicaltrials.gov/ct2/show/NCT02724865.
Collapse
|
61
|
Stipa C, Incerti-Parenti S, Cameli M, Ippolito DR, Gracco A, Alessandri-Bonetti G. Antero-Posterior Mandibular Excursion in Obstructive Sleep Apnea Patients Treated with Mandibular Advancement Device: A Retrospective Cohort Study. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:3561. [PMID: 36834252 PMCID: PMC9960680 DOI: 10.3390/ijerph20043561] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Revised: 02/13/2023] [Accepted: 02/15/2023] [Indexed: 06/18/2023]
Abstract
Since obstructive sleep apnea (OSA) management with a mandibular advancement device (MAD) is likely to be life-long, potential changes in mandibular movements during therapy should be investigated. The purpose of this study was to use a method that has already been shown to be reliable in order to determine whether the range of antero-posterior mandibular excursion, the procedure upon which MAD titration is based, varies between baseline (T0) and at least 1 year of treatment (T1). The distance between maximal voluntary protrusion and maximal voluntary retrusion determined using the millimetric scale of the George Gauge was retrospectively collected from the medical records of 59 OSA patients treated with the MAD and compared between T0 and T1. A regression analysis was performed to evaluate the influence of treatment time, MAD therapeutic advancement and the patient's initial characteristics in excursion range variation. A statistically significant increase of 0.80 ± 1.52 mm (mean ± standard deviation, p < 0.001) was found for antero-posterior mandibular excursion. The longer the treatment time (p = 0.044) and the smaller the patient's mandibular excursion at T0 (p = 0.002), the greater the increase was. These findings could be explained by a muscle-tendon unit adaptation to the forward mandibular repositioning induced by the MAD. During MAD therapy, patients can develop a wider range of antero-posterior mandibular excursion, especially those with a smaller initial excursion capacity.
Collapse
|
62
|
Lowery MM, Rundo JV, Walia HK, Shah V. Personalized multimodal management for severe obstructive sleep apnea in a patient intolerant of positive airway pressure with hypoglossal nerve stimulator and mandibular advancement device. J Clin Sleep Med 2023; 19:403-408. [PMID: 36117433 PMCID: PMC9892739 DOI: 10.5664/jcsm.10296] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Revised: 09/13/2022] [Accepted: 09/14/2022] [Indexed: 02/04/2023]
Abstract
Treatment of moderate to severe obstructive sleep apnea poses clinical challenges in persons with intolerance or inadequate response to traditional treatment modalities, including positive airway pressure and mandibular advancement devices. Hypoglossal nerve stimulation is a new treatment option, but few management guidelines exist when it is intolerable or ineffective. Combining several treatment modalities has been an effective strategy for improving symptoms, tolerance, and efficacy. We describe a patient intolerant to positive airway pressure therapy who had continued sleepiness, morning headaches, and snoring with a mandibular advancement device. He underwent hypoglossal nerve stimulation implantation but was intolerant of the voltages required to adequately control his obstructive sleep apnea. Multimodal management with hypoglossal nerve stimulation, mandibular advancement device, and positional therapy was successfully implemented to improve sleepiness, nocturnal symptoms, and the apnea-hypopnea index. This case highlights the personalization and adaptability of combination therapy to suit patient needs while effectively controlling obstructive sleep apnea. CITATION Lowery MM, Rundo JV, Walia HK, Shah V. Personalized multimodal management for severe obstructive sleep apnea in a patient intolerant of positive airway pressure with hypoglossal nerve stimulator and mandibular advancement device. J Clin Sleep Med. 2023;19(2):403-408.
Collapse
|
63
|
Losev FF, Starikov NA, Babunashvili GB, Rudakov AM, Vataeva AA. [Duration of splint therapy in patients with temporomandibular joint disorders]. STOMATOLOGIIA 2023; 102:37-43. [PMID: 38096393 DOI: 10.17116/stomat202310206237] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
AIM Studying the duration of treatment in patients with temporomandibular joint pain dysfunction syndrome, and the relationship of the duration of treatment with the age of the patient at the beginning of therapy. MATERIALS AND METHODS The study was carried out using information from medical records of dental patients, information from additional examinations of patients who were treated at the National Medical Research Centre for Dentistry and Maxillofacial Surgery of the Ministry of Health of Russia from 2016 to 2022. Statistical research methods: to evaluate the normality of the distribution, graphical methods were used, as well as the Shapiro-Wilk criterion. RESULTS The duration of splint therapy in patients with temporomandibular joint pain dysfunction syndrome varied from 4 to 27 months. The average duration of treatment of patients using occlusive splints was 10.5±5.3 months. Without abnormal observations, the average duration of splint therapy in patients with TMJ pain syndrome was 9.6±4.1 months. The obtained data allow stating the absence of a correlation between the age of patients and the duration of splint-therapy. CONCLUSION The majority of patients (68.4%) complete the splint therapy stage within 1 year, and a very small part (1.8%) are treated for more than 1.5 years. The duration of treatment of patients with temporomandibular joint pain dysfunction syndrome does not depend on age or gender.
Collapse
|
64
|
Levine M, Cantwell M, Postol K, Schwartz D. Comparison of a noncustom vs custom mandibular advancement device to treat obstructive sleep apnea. J Clin Sleep Med 2023; 19:205-206. [PMID: 36148629 PMCID: PMC9806772 DOI: 10.5664/jcsm.10316] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 09/20/2022] [Accepted: 09/20/2022] [Indexed: 01/07/2023]
|
65
|
Buyse B, Nguyen PAH, Leemans J, Verhaeghe V, Peters M, Strobbe S, Van Valckenborgh I, Belge C, Testelmans D. Short-term positive effects of a mandibular advancement device in a selected phenotype of patients with moderate obstructive sleep apnea: a prospective study. J Clin Sleep Med 2023; 19:5-16. [PMID: 35962942 PMCID: PMC9806777 DOI: 10.5664/jcsm.10232] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Revised: 08/05/2022] [Accepted: 08/05/2022] [Indexed: 01/07/2023]
Abstract
STUDY OBJECTIVES To evaluate (determinants of) treatment success of mandibular advancement device application in a selected phenotype of patients with obstructive sleep apnea (OSA). METHODS Ninety nonobese patients with moderate OSA (obstructive apnea-hypopnea index [OAHI] ≥ 15 and < 30 events/h) without comorbidities were prospectively included. Polysomnography was performed at baseline and with a mandibular advancement device. A drug-induced sleep endoscopy with jaw thrust was performed in 83%. RESULTS OAHI reduction ≥ 50% was observed in 73%, OAHI reduction ≥ 50% with OAHI < 10 events/h in 70%, and complete OSA resolution (OAHI < 5 events/h) in 40%. Patients with nonpositional OSA showed a significantly higher rate of complete OSA resolution: Posttest probability increased to 67%. In patients with total disappearance of collapse at velum level and at all levels during drug-induced sleep endoscopy with jaw thrust, the drop in OAHI was impressive with an infinitively high positive likelihood ratio. However, the proportion of patients having nonpositional OSA or the drug-induced sleep endoscopy characteristics as described above was < 20%. The change in snoring disturbance based on a visual analog scale was 76% (interquartile range 40-89%, P < .001) and a statistically significant amelioration in Epworth Sleepiness Scale (especially in somnolent subjects) was observed. High adherence was reported. CONCLUSIONS In this predefined OSA phenotype, a mandibular advancement device was effective in reduction of OAHI and in amelioration of symptoms. Stratification by nonpositional OSA and findings on drug-induced sleep endoscopy with jaw thrust increased treatment success defined as reduction in OAHI. However, the clinical relevance can be questioned because only a small number of patients demonstrated these characteristics. CITATION Buyse B, Nguyen PAH, Leemans J, et al. Short-term positive effects of a mandibular advancement device in a selected phenotype of patients with moderate obstructive sleep apnea: a prospective study. J Clin Sleep Med. 2023;19(1):5-16.
Collapse
|
66
|
Uniken Venema JAM. [A PhD completed. Predictability and long-term effects of MAD treatment of obstructive sleep apnea]. Ned Tijdschr Tandheelkd 2022; 129:557-561. [PMID: 36472309 DOI: 10.5177/ntvt.2022.12.22077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Obstructive sleep apnea is a sleep-related breathing disorder, characterized by repetitive obstruction of the upper airway during sleep. Obstructive sleep apnea can be treated with a mandibular advancement device (MAD), which advances the mandibula into a forward position, thus preventing obstruction of the upper airway. Different MAD designs are available, however, clinically significant differences in effectiveness have not been found. Besides this, a randomized crossover study found the effectiveness of a new 'boil and bite' MAD to be equal to that of the custom MAD. After a 10-year follow-up, too, the MAD has been proven to be a successful treatment option. However, attention must be paid to minimalizing dental side effects, such as tooth repositioning.
Collapse
|
67
|
Diaz de Teran T, Muñoz P, de Carlos F, Macias E, Cabello M, Cantalejo O, Banfi P, Nicolini A, Solidoro P, Gonzalez M. Mandibular Torus as a New Index of Success for Mandibular Advancement Devices. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:14154. [PMID: 36361031 PMCID: PMC9657412 DOI: 10.3390/ijerph192114154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Revised: 10/26/2022] [Accepted: 10/27/2022] [Indexed: 06/16/2023]
Abstract
BACKGROUND In obstructive sleep apnoea (OSA), treatment with mandibular advancement devices (MADs) reduces patients' Apnoea-Hypopnoea index (AHI) scores and improves their sleepiness and quality of life. MADs are non-invasive alternatives for patients who cannot tolerate traditional continuous positive airway pressure (CPAP) therapy. The variability of responses to these devices makes it necessary to search for predictors of success. The aim of our study was to evaluate the presence of mandibular torus as a predictor of MAD efficacy in OSA and to identify other potential cephalometric factors that could influence the response to treatment. METHODS This was a retrospective cohort study. The study included 103 patients diagnosed of OSA who met the criteria for initiation of treatment with MAD. Structural variables were collected (cephalometric and the presence or absence of mandibular torus). Statistical analysis was performed to evaluate the existence of predictive factors for the efficacy of MADs. RESULTS A total of 103 patients who were consecutively referred for treatment with MAD were included (89.3% men); the mean age of the participants was 46.3 years, and the mean AHI before MAD was 31.4 (SD 16.2) and post- MAD 11.3 (SD 9.2). Thirty-three percent of patients had mandibular torus. Torus was associated with a better response (odds ratio (OR) = 2.854 (p = 0.035)) after adjustment for sex, age, body mass index (BMI; kg/m2), the angle formed by the occlusal plane to the sella-nasion plane (OCC plane to SN), overinjection, and smoking. No cephalometric predictors of efficacy were found that were predictive of MAD treatment success. CONCLUSIONS The presence of a mandibular torus practically triples the probability of MAD success. This is the simplest examination with the greatest benefits in terms of the efficacy of MAD treatment for OSA.
Collapse
|
68
|
Vimal J, Dutt P, Singh N, Singh BP, Chand P, Jurel S. To compare different non-surgical treatment modalities on treatment of obstructive sleep apnea: A systematic review and meta-analysis. J Indian Prosthodont Soc 2022; 22:314-327. [PMID: 36511065 PMCID: PMC9709867 DOI: 10.4103/jips.jips_261_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2022] [Revised: 07/28/2022] [Accepted: 07/29/2022] [Indexed: 11/07/2022] Open
Abstract
The study aimed to assess the effect of mandibular advancement device (MAD) in patients with obstructive sleep apnea for reduction in 24-h mean blood pressure, sleep quality, Apnea Hypopnea Index (AHI), and patient compliance, compared to continuous positive airway pressure (CPAP), other interventions, or no treatment. Three different databases such as PubMed, EMBASE, and CENTRAL were searched using different search terms till July 2021 as per the inclusion and exclusion criteria. After inclusion of studies, data extraction including risk of bias assessment was done. For each study, we used odds ratio, mean difference, and 95% confidence interval to assess and synthesize the outcomes. The quality of evidence was evaluated as per the Grading of Recommendations, Assessment, Development, and Evaluation (GRADE). Twenty-one randomized controlled trials were included: 497 patients in the MAD group, 239 patients in the CPAP group, and 274 patients in the sham group. In MAD-CPAP comparison, the results favored CPAP in the reduction of AHI of 3.48 (1.76-5.19). However, unclear results were found for sleep quality measured as Epworth Sleepiness Scale (ESS), patient compliance, and 24-h mean blood pressure. In MAD-sham comparison, the results favored MAD in the reduction of AHI of - 8.39 (-10.90--5.88] and ESS of - 0.91 (-1.70--0.12) and favored sham in terms of patient compliance while, unclear results for 24-h mean blood pressure. The GRADE score indicated that the quality of evidence is very low, low, and moderate for different outcomes. CPAP in comparison to MAD and MAD in comparison to sham showed a significant AHI reduction. However, patient compliance and 24-h mean blood pressure were not significantly different in MAD-CPAP or MAD-sham. Quality of evidence is very low and low when MAD was compared with CPAP and sham, respectively, for AHI.
Collapse
|
69
|
Bosschieter PF, Uniken Venema JA, Vonk PE, Ravesloot MJ, Hoekema A, Plooij JM, Lobbezoo F, de Vries N. Equal effect of a noncustom vs a custom mandibular advancement device in treatment of obstructive sleep apnea. J Clin Sleep Med 2022; 18:2155-2165. [PMID: 35532113 PMCID: PMC9435323 DOI: 10.5664/jcsm.10058] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Revised: 04/11/2022] [Accepted: 04/12/2022] [Indexed: 11/13/2022]
Abstract
STUDY OBJECTIVES Numerous types of mandibular advancement devices (MADs) are available to treat patients with obstructive sleep apnea, varying from noncustom to custom devices. Only a limited number of studies have been performed to determine whether a noncustom MAD could be used to predict treatment success of a custom MAD. In this study, we investigated the potential of a new-generation noncustom MAD, by comparing its effectiveness with a custom MAD. We hypothesized that the effectiveness of the devices is similar with regard to both objective (polysomnography) and self-reported (questionnaires, adherence, and patient satisfaction) outcomes. METHODS This was a single-center prospective randomized crossover study including a consecutive series of patients with obstructive sleep apnea. Patients were randomized to start either with the noncustom or custom MAD. Both MADs were applied for 12 weeks, followed by polysomnography with MAD in situ and questionnaires. After the first 12 weeks of follow-up, a washout period of 1 week was applied. Equal effectiveness was defined as no significant differences in both objective and self-reported outcomes between both devices. RESULTS Fifty-eight patients were included; 40 completed the full follow-up. The median apnea-hypopnea index significantly decreased from 16.3 (7.7, 24.8) events/h to 10.7 (5.6, 16.6) events/h with the custom MAD (P = .010) and to 7.8 (2.9, 16.1) events/h with the noncustom MAD (P < .001). Self-reported outcomes significantly improved in both groups. No significant differences were found between both devices. CONCLUSIONS The effectiveness of a noncustom and custom MAD is comparable, which suggests that a noncustom MAD can be used as a selection tool for MAD treatment eligibility to improve MAD treatment outcome. CLINICAL TRIAL REGISTRATION Registry: Netherlands Trial Register; Name: The Use of a Boil and Bite Mandibular Advancement Device vs a Custom Mandibular Advancement Device in Obstructive Sleep Apnea Management; URL: https://www.trialregister.nl/trial/7249; Identifier: NL64738.100.18. CITATION Bosschieter PFN, Uniken Venema JAM, Vonk PE, et al. Equal effect of a noncustom vs a custom mandibular advancement device in treatment of obstructive sleep apnea. J Clin Sleep Med. 2022;18(9):2155-2165.
Collapse
|
70
|
Denardin ACS, do Nascimento LP, Valesan LF, Da Cas CD, Pauletto P, Garanhani RR, Januzzi E, Hilgert LA, de Souza BDM. Disocclusion guides in occlusal splints on temporomandibular disorders and sleep bruxism: A systematic review. Oral Surg Oral Med Oral Pathol Oral Radiol 2022; 135:51-64. [PMID: 36241594 DOI: 10.1016/j.oooo.2022.07.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 06/08/2022] [Accepted: 07/12/2022] [Indexed: 11/16/2022]
Abstract
OBJECTIVE To determine the best disocclusion guidance in occlusal splints (OSs) to manage and treat temporomandibular disorder (TMD) and sleep bruxism (SB). STUDY DESIGN The research was conducted on 7 major electronic databases and 3 gray literature sources. We included randomized trials, nonrandomized clinical trials, and before-and-after studies. The risk of bias (RoB) was assessed by Joanna Briggs Institute of Critical Appraisal Tools. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach was used to grade the certainty of evidence. RESULTS Qualitative synthesis included 16 surveys reporting data from 620 participants. Canine guidance (CG) was widely searched. Bilateral balanced occlusion (BBO) and CG significantly decreased pain levels compared with the placebo splint. Comparing between OS and absence of therapy, only CG was assessed and showed significant improvements on mouth opening, pain, sleep quality, and muscle activity. When compared different guide types among themselves, no significant improvement was founded in any evaluated outcome. Three studies presented high RoB, 7 presented moderate RoB, and 6 presented low RoB. CONCLUSIONS It is suggested there is not enough evidence to support that there are any specific kind of guidance responsible for improving evaluated outcomes on TMD and SB.
Collapse
|
71
|
Piskin B, Uyar A. Concerns regarding the published article "Evaluation of mandibular advancement device placement based on levels of TNF-alpha in participants with obstructive sleep apnea: A clinical study" by Solanki et al. J Prosthet Dent 2022; 128:118. [PMID: 35623918 DOI: 10.1016/j.prosdent.2022.01.042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2022] [Revised: 01/28/2022] [Accepted: 01/28/2022] [Indexed: 11/15/2022]
|
72
|
Burns RH. TMD splint construction. JOURNAL OF CLINICAL ORTHODONTICS : JCO 2022; 56:384-389. [PMID: 36067126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
|
73
|
Sánchez-Jáuregui E, Baranda-Manterola E, Ranz-Colio Á, Bueno de Vicente Á, Acero-Sanz J. Custom made cutting guides and osteosynthesis plates versus CAD/CAM occlusal splints in positioning and fixation of the maxilla in orthognathic surgery: A prospective randomized study. J Craniomaxillofac Surg 2022; 50:609-614. [PMID: 35760659 DOI: 10.1016/j.jcms.2022.05.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Revised: 04/22/2022] [Accepted: 05/30/2022] [Indexed: 11/19/2022] Open
Abstract
The aim of this study is to compare the accuracy of maxilla positioning in orthognathic surgery with the use of custom-made devices (cutting guides and patient-fitted osteosynthesis plates) comparing to CAD/CAM splints. A prospective randomized study was performed. Patients with dentofacial deformities undergoing orthognathic surgery were compared, using customized guides (experimental group) vs. CAD/CAM surgical splints (control group) for the repositioning of the upper maxilla. Preoperative and postoperative CT scans were used to compare positioning and fixation of the maxilla in the three planes of space. A total of 30 patients were included in the study (15 patients in each study group). The mean error obtained with customized guides was 0.8 mm (range 0.1-1.9) in the anterior-posterior axis, 0.4 mm (range 0-1.4) in the vertical axis and 0.2 mm (range 0-1.1) in the horizontal axis. There were statistically significant differences in the anterior-posterior and vertical axes in favour of the customized implants, whereas there were no differences in the horizontal plane. Furthermore, there was a mean reduction of the operative time of 36.5 min in the experimental group. Within the limitations of the study it seems that patient specific surgical guides should be preferred when accuracy of repositioning of the maxilla and saving operative time are the priority.
Collapse
|
74
|
Wang Y, Wang P, Xiang X, Xu H, Tang Y, Zhou Y, Bai D, Xue C. Effect of occlusal coverage depths on the precision of 3D-printed orthognathic surgical splints. BMC Oral Health 2022; 22:218. [PMID: 35655203 PMCID: PMC9161535 DOI: 10.1186/s12903-022-02247-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Accepted: 05/23/2022] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND Precise orthognathic surgical splints are important in surgical-orthodontic treatment. This study aimed to propose a standardized protocol for three-dimensional (3D)-printed splints and assess the precision of splints with different occlusal coverage on the dentition (occlusal coverage depth, OCD), thus optimizing the design of 3D-printed splints to minimize the seemingly unavoidable systematic errors. METHODS Resin models in optimal occlusion from 19 patients were selected and scanned. Intermediate splints (ISs) and final splints (FSs) with 2-mm, 3-mm, 4-mm, and 5-mm OCDs were fabricated and grouped as IS-2, IS-3, IS-4, IS-5, FS-2, FS-3, FS-4, and FS-5, respectively. The dentitions were occluded with each splint and scanned as a whole to compare with the original occlusion. Translational and rotational deviations of the lower dentition and translational deviations of the landmarks were measured. RESULTS For vertical translation, the lower dentitions translated inferiorly to the upper dentition in most of the splints, and the translation increased as OCD got larger. Vertical translations of the dentitions in 89.47% of IS-2, 68.42% of IS-3, 42.11% of IS-4, 10.53% of IS-5, 94.74% of FS-2, 63.16% of FS-3, 26.32% of FS-4, and 21.05% of FS-5 splints were below 1 mm, respectively. For pitch rotation, the lower dentitions rotated inferiorly and posteriorly in most groups, and the rotation increased as OCD got larger. Pitch rotations of the dentitions in 100% of IS-2, 89.47% of IS-3, 57.89% of IS-4, 52.63% of IS-5, 100.00% of FS-2, 78.95% of FS-3, 52.63% of FS-4, and 47.37% of FS-5 splints were below 2°, respectively. On the other hand, the transversal and sagittal translations, roll and yaw rotations of most groups were clinically acceptable (translation < 1 mm and rotation < 2°). The deviations of ISs and FSs showed no statistical significance at all levels of coverage (P > 0.05). CONCLUSIONS A protocol was proposed to generate 3D-printed ISs and FSs with normalized basal planes and standardized OCDs. Deviations of the ISs and FSs were more evident in the vertical dimension and pitch rotation and had a tendency to increase as the OCD got larger. ISs and FSs with both 2-mm and 3-mm OCD are recommendable regarding the precision relative to clinical acceptability. However, considering the fabrication, structural stability, and clinical application, ISs and FSs with 3-mm OCD are recommended for accurate fitting.
Collapse
|
75
|
Bilir H, Kurt H. Influence of Stabilization Splint Thickness on Temporomandibular Disorders. INT J PROSTHODONT 2022; 35:163-173. [PMID: 35507529 DOI: 10.11607/ijp.6923] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
PURPOSE To assess the effect of stabilization splint (SS) thickness on temporomandibular disorders (TMDs). MATERIALS AND METHODS Participants were selected from patients who applied to the clinic with a complaint of temporomandibular disorders (TMDs). Symptoms were evaluated with the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD). Regarding the treatment plan, patients were divided into two groups: the 2-mm-thick splint group (2-mm TSG) and the 4-mm-thick splint group (4-mm TSG). They used SSs at night (8 hours) and were recalled 1, 2, 3, and 6 months after splint insertion. At the end of the study, 72 patients (2-mm TSG = 39, 4-mm TSG = 33) had completed the 6-month follow-up. The SPSS program was used for statistical analysis. The results of the analysis were evaluated at a significance level of .05. RESULTS Pain in the muscles decreased significantly in the muscle disorders and combined groups (both 2- and 4-mm TSG) after 6 months of treatment (P < .05). In the combined group, TMJ sounds significantly decreased after 6 months of treatment, and there was a statistically significant difference between the 2-mm TSG and the 4-mm TSG (P = .045). Also, in the combined group, maximum unassisted opening (MUO) values of patients treated with 2-mm-thick splints decreased after 6 months of treatment (P = .022). CONCLUSION Both 2-mm-thick and 4-mm-thick splints were effective in the treatment of muscle disorders and disc displacements, especially in muscle-related pain and TMJ sound symptoms.
Collapse
|