51
|
Jurow K, Gauvreau K, Maschietto N, Prakash A. Growth of the right ventricular outflow tract in repaired tetralogy of Fallot: A longitudinal CMR study. J Cardiovasc Magn Reson 2024; 26:100002. [PMID: 38211659 DOI: 10.1016/j.jocmr.2023.100002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Accepted: 12/11/2023] [Indexed: 01/13/2024] Open
Abstract
BACKGROUND Many patients with repaired tetralogy of Fallot require pulmonary valve replacement (PVR) due to significant pulmonary regurgitation (PR). Transcatheter PVR (TPVR) is an equally effective and less invasive alternative to surgical PVR but many native right ventricular outflow tracts (RVOTs) are too large for TPVR at time of referral. Understanding the rate of growth of the RVOT may help optimize timing of referral. This study aims to examine the longitudinal growth of the native RVOT over time in repaired tetralogy of Fallot (TOF). METHODS A retrospective review of serial cardiac MRI cardiovascular magnetic resonance (CMR) data from 121 patients with repaired TOF and a native RVOT (median age at first CMR 14.7 years, average interval between the first and last CMR of 8.1 years) was performed to measure serial changes in RVOT diameter, cross-sectional area, perimeter-derived diameter, and length. RESULTS All parameters of RVOT size continued to grow with increasing age but growth was more rapid in the decade after TOF repair (for minimum systolic diameter, mean increase of 5.7 mm per 10 years up to year 12, subsequently 2.3 mm per 10 years). The RVOT was larger with a transannular patch and in patients without pulmonary stenosis (p < 0.001 for both), but this was not associated with rate of growth. More rapid RVOT enlargement was noted in patients with larger right ventricular end-diastolic volume (RVEDV), higher PR fraction, and greater rates of increases in RVEDV and PR (p < 0.001 for all) CONCLUSIONS: in patients with repaired TOF, using serial CMR data, we found that RVOT size increased progressively at all ages, but the rate was more rapid in the first decade after repair. More rapid RVOT enlargement was noted in patients with a larger RV, more PR, and greater rates of increases in RV size and PR severity. These results may be important in considering timing of referral for transcatheter pulmonary valves, in planning transcatheter and surgical valve replacement, and in designing future valves for the native RVOT.
Collapse
|
52
|
Turek JW, Kang L, Overbey DM, Carboni MP, Rajab TK. Partial Heart Transplant in a Neonate With Irreparable Truncal Valve Dysfunction. JAMA 2024; 331:60-64. [PMID: 38165407 PMCID: PMC10762570 DOI: 10.1001/jama.2023.23823] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/23/2023] [Accepted: 10/24/2023] [Indexed: 01/03/2024]
Abstract
Importance The treatment of neonates with irreparable heart valve dysfunction remains an unsolved problem because there are no heart valve implants that grow. Therefore, neonates with heart valve implants are committed to recurrent implant exchanges until an adult-sized valve can fit. Objective To deliver the first heart valve implant that grows. Design, Setting, and Participants Case report from a pediatric referral center, with follow-up for more than 1 year. Participants were a recipient neonate with persistent truncus arteriosus and irreparable truncal valve dysfunction and a donor neonate with hypoxic-ischemic brain injury. Intervention First-in-human transplant of the part of the heart containing the aortic and pulmonary valves. Main Outcomes and Measures Transplanted valve growth and hemodynamic function. Results Echocardiography demonstrated adaptive growth and excellent hemodynamic function of the partial heart transplant valves. Conclusions and Relevance In this child, partial heart transplant delivered growing heart valve implants with a good outcome at age 1 year. Partial heart transplants may improve the treatment of neonates with irreparable heart valve dysfunction.
Collapse
|
53
|
Siondalski P, Kołaczkowska M, Bieńkowski M, Pęksa R, Kowalik MM, Dawidowska K, Vandendriessche K, Meuris B. Bacterial cellulose as a promising material for pulmonary valve prostheses: In vivo study in a sheep model. J Biomed Mater Res B Appl Biomater 2024; 112:e35355. [PMID: 38247240 DOI: 10.1002/jbm.b.35355] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 10/18/2023] [Accepted: 11/09/2023] [Indexed: 01/23/2024]
Abstract
OBJECTIVES Currently, no consensus exists regarding the most durable prosthesis for pulmonary valve replacement. Bacterial cellulose is a resistant, nonbiodegradable, nonpyrogenic bioimplant with low hemolysis and clotting properties. We hypothesized that bacterial cellulose heart valve prostheses could be an attractive alternative for pulmonary valve replacement. METHODS We conducted a large animal model experiment in three adult sheep. The animals underwent open-heart surgery and cardiopulmonary bypass for bacterial cellulose conduit implantation in the pulmonary position. The sheep were followed for seven months, and clinical and laboratory parameters were analyzed. Echocardiographic evaluations were performed at 3 and 7 months. After seven months, the sheep were sacrificed and an autopsy was performed. The explanted conduits were radiologically and histopathologically analyzed. RESULTS All sheep survived the operation, showing good recovery and normal health status; no adverse events were noted during the 7-month postoperative follow-up. Interval laboratory findings were normal with no signs of hemolysis or infection. Echocardiographic analysis after 7 months revealed a normal mean pressure gradient with excellent cusp motion and coaptation; a trace of regurgitation was found in two sheep. X-ray analysis of the explanted conduits revealed no structural defects in the leaflets with minimal calcification. Histological examination showed slight thickening of the conduit by pannus formation. No material failure, no calcification inside the material, and only minor calcification extrinsic to the matrix were observed. CONCLUSIONS This pilot study provides evidence that bacterial cellulose may be suitable for pulmonary valve prostheses and surgical pulmonary artery plasty. Further studies on the high pressure side of the left heart are needed.
Collapse
|
54
|
Manukyan SN, Soynov IA, Voytov AV, Rzaeva KA, Baranov AA, Bogachev-Prokofiev AV. [Modern possibilities for transcatheter pulmonary valve replacement]. Khirurgiia (Mosk) 2024:32-44. [PMID: 38344958 DOI: 10.17116/hirurgia202402132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/15/2024]
Abstract
The literature review is devoted to transcatheter pulmonary valve replacement. The authors summarize the indications, clinical data and current capabilities of transcatheter pulmonary valve replacement. The authors also overviewed modern valves for transcatheter pulmonary artery replacement. Effectiveness of transcatheter pulmonary valve implantation has been substantiated. Various studies comparing the outcomes of different valve systems for endovascular implantation were analyzed. The authors concluded the prospects for transcatheter pulmonary valve implantation.
Collapse
|
55
|
Ishigaki T, Wakasa S, Sato K, Kato N, Kamikubo Y. Reconstruction of right ventricular outflow tract with severe calcification: lantern procedure. Gen Thorac Cardiovasc Surg 2024; 72:58-60. [PMID: 37620708 DOI: 10.1007/s11748-023-01973-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Accepted: 08/15/2023] [Indexed: 08/26/2023]
Abstract
Right ventricular outflow tract reconstruction is repeatedly required after the Rastelli procedure. However, standard right ventricular outflow tract reconstruction using direct anastomosis on the posterior right ventricular outflow tract wall is unfeasible in cases with severe calcification. Herein, we present a novel technique called the "lantern procedure," which can fix the prosthetic pulmonary valve without anastomosis to the calcified right ventricular outflow tract wall.
Collapse
|
56
|
Müller M, Biermann D, Righa MM, Carstens H, Kozlik-Feldmann RG, Hübler M, Sachweh JS. The Ongoing Debate: Longevity of Biological Valves in Pulmonary Position. Thorac Cardiovasc Surg 2024; 72:e1-e6. [PMID: 38688313 DOI: 10.1055/a-2316-8828] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/02/2024]
Abstract
BACKGROUND In patients with tetralogy of Fallot (ToF) or ToF-like anatomy, factors possibly impacting the longevity of biological valves in the pulmonary position were investigated. METHOD Between 1997 and 2017, 79 consecutive hospital survivors with a median age of 8.7 years (range: 0.2-56.1 years; interquartile range [IQR]: 14.8 years) with ToF or ToF-like anatomy underwent surgical implantation of Contegra (n = 34), Hancock (n = 23), Perimount (n = 9), pulmonary homograft (n = 9), and miscellaneous (n = 4) conduits. The median internal graft diameter was 19 mm (range: 11-29 mm; IQR: 8 mm) which refers to a median z-score of 0.6 standard deviation (SD) (range: -1.8 to 4.0 SD; IQR: 2.1 SD). RESULTS The median time of follow-up was 9.4 years (range: 1.1-18.8 years; IQR: 6.0 years). Thirty-nine patients (49%) underwent surgical (n = 32) or interventional (n = 7) pulmonary valve re-replacement. Univariate Cox regression revealed patient age (p = 0.018), body surface area (p = 0.004), internal valve diameter (p = 0.005), and prosthesis z-score (p = 0.018) to impact valve longevity. Multivariate Cox regression analysis, however, did not show any significant effect (likely related to multicollinearity). Subgroup analysis showed that valve-revised patients have a higher average z-score (p = 0.003) and younger average age (p = 0.007). CONCLUSION A decreased longevity of biological valves in the pulmonary position is related to younger age, lower valve diameter, and higher z-score. Because valve size (diameter and z-score) can be predicted by age, patient age is the crucial parameter influencing graft longevity.
Collapse
|
57
|
Montaña-Jiménez LP, Aristizabal AM, Mosquera-Álvarez W, Gutiérrez-Gil J, Ponce-Bravo LE, Beltrán E, Mejía-Quiñones V, Zunzunegui JL. Management of right ventricular outflow tract with percutaneous Melody valve implantation in pediatric patients: experience in a high complexity center in Colombia. ARCHIVOS DE CARDIOLOGIA DE MEXICO 2024; 94:7-14. [PMID: 38507314 PMCID: PMC11160522 DOI: 10.24875/acm.22000226] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2022] [Accepted: 04/06/2023] [Indexed: 03/22/2024] Open
Abstract
BACKGROUND Congenital heart disease poses a therapeutic challenge, specifically pulmonary valve stenosis. This has been treated for many years with invasive procedures and bioprostheses, which over time, become dysfunctional due to the accumulation of fibrous tissue and calcification. OBJECTIVE The aim of this study is to describe the use of endovascular management in the right ventricular outflow tract, as the beginning of an ongoing effot to improve pediatric outcomes in developing countries. METHODS Seven pediatric patients with endovascular management of the right outflow tract are presented. Three of them underwent surgical valvuloplasty with persistent pulmonary stenosis. They decided to insert a percutaneous transcatheter pulmonary valve (PPVI) with a Melody valve using the valve-in-valve technique, with 100% stenosis and no complications associated with the procedure. RESULTS Four patients with successful percutaneous valve implantation had different congenital heart diseases. In addition, the case of a patient in whom an intentional pulmonary valve fracture was performed, an innovative procedure in pediatric endovascular management in the country, is highlighted. CONCLUSIONS The procedure was minimally invasive, safe, and effective. The IVPP technique could be a viable option in our country for managing failed primary valve implantations or even in native tracts.
Collapse
|
58
|
Ishigami S, Ye XT, Buratto E, Ivanov Y, Chowdhuri KR, Fulkoski N, Robertson T, Davies B, Brizard CP, Konstantinov IE. Long-term outcomes of tetralogy of Fallot repair: A 30-year experience with 960 patients. J Thorac Cardiovasc Surg 2024; 167:289-302.e11. [PMID: 37169063 DOI: 10.1016/j.jtcvs.2023.04.015] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 04/13/2023] [Accepted: 04/13/2023] [Indexed: 05/13/2023]
Abstract
OBJECTIVE This study evaluates the long-term results of tetralogy of Fallot repair and assesses the risk factors for adverse outcomes. METHODS This retrospective study included 960 patients who underwent transatrial transpulmonary tetralogy of Fallot repair between 1990 and 2020. RESULTS A transannular patch was placed in 722 patients, and pulmonary valve preservation was achieved in 233 patients. The median age at tetralogy of Fallot repair was 9.4 (interquartile range, 6.2-14.2) months. The median follow-up duration was 10.6 (interquartile range, 5.4-16.3) years. There were 8 early deaths (0.8%) and 20 late deaths (2.1%). Genetic syndrome and pulmonary valve annulus Z score less than -3 were risk factors for mortality. The survival was 97.7% (95% confidence interval, 96.4-98.5) and 94.5% (95% confidence interval, 90.9-96.7) at 10 and 30 years, respectively. Freedom from any reoperation was 86.4% (95% confidence interval, 83.6-88.7) and 65.4% (95% confidence interval, 59.8-70.4) at 10 and 20 years, respectively. Postoperative right ventricular outflow tract peak gradient of 25 mm Hg or greater correlated with reoperation. Propensity score-matched analysis demonstrated that freedom from pulmonary valve replacement at 15 years was higher in the pulmonary valve preservation group compared with the transannular patch group (98.2% vs 78.4%, P = .004). Freedom from reoperation for right ventricular outflow tract obstruction at 15 years was lower in the pulmonary valve preservation group compared with the transannular patch group (P = .006). CONCLUSIONS The long-term outcomes of tetralogy of Fallot repair are excellent. A postoperative right ventricular outflow tract peak gradient less than 25 mm Hg appears to be optimal to prevent reoperation. If the pulmonary valve size is suitable, pulmonary valve preservation reduces the risk of pulmonary valve replacement, yet increases the reoperation rate for right ventricular outflow tract obstruction.
Collapse
|
59
|
Han BK, Garcia S, Aboulhosn J, Blanke P, Martin MH, Zahn E, Crean A, Overman D, Craig CH, Hanneman K, Semple T, Armstrong A. Technical recommendations for computed tomography guidance of intervention in the right ventricular outflow tract: Native RVOT, conduits and bioprosthetic valves:: A white paper of the Society of Cardiovascular Computed Tomography (SCCT), Congenital Heart Surgeons' Society (CHSS), and Society for Cardiovascular Angiography & Interventions (SCAI). J Cardiovasc Comput Tomogr 2024; 18:75-99. [PMID: 37517984 DOI: 10.1016/j.jcct.2023.06.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 05/03/2023] [Accepted: 06/20/2023] [Indexed: 08/01/2023]
Abstract
This consensus document for the performance of Cardiovascular Computed Tomography (CCT) to guide intervention in the right ventricular outflow tract (RVOT) in patients with congenital disease (CHD) was developed collaboratively by pediatric and adult interventionalists, surgeons and cardiac imagers with expertise specific to this patient subset. The document summarizes definitions of RVOT dysfunction as assessed by multi-modality imaging techniques and reviews existing consensus statements and guideline documents pertaining to indications for intervention. In the context of this background information, recommendations for CCT scan acquisition and a standardized approach for reporting prior to surgical or transcatheter pulmonary valve replacement are proposed and presented. It is the first Imaging for Intervention collaboration for CHD patients and encompasses imaging and reporting recommendations prior to both surgical and percutaneous pulmonary valve replacement.
Collapse
|
60
|
Figueras-Coll M, Betrián-Blasco P. Alterra device and Edwards SAPIEN 3. Pushing the boundaries of percutaneous pulmonary valve implantation. REVISTA ESPANOLA DE CARDIOLOGIA (ENGLISH ED.) 2024; 77:97-99. [PMID: 37625645 DOI: 10.1016/j.rec.2023.08.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Accepted: 06/28/2023] [Indexed: 08/27/2023]
|
61
|
Discussion to: Long-term outcomes of tetralogy of Fallot repair: A 30-year experience with 960 patients. J Thorac Cardiovasc Surg 2024; 167:303-304. [PMID: 37777954 DOI: 10.1016/j.jtcvs.2023.09.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Indexed: 10/02/2023]
|
62
|
Sengupta A, Pastuszko P, Zaidi AN, Murthy RA. Early Outcomes of Pulmonary Valve Replacement With the Edwards Inspiris Resilia Pericardial Bioprosthesis. World J Pediatr Congenit Heart Surg 2024; 15:52-59. [PMID: 37722839 DOI: 10.1177/21501351231178750] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/20/2023]
Abstract
BACKGROUND Controversy regarding the optimal pulmonary valve substitute remains, with no approved surgical valve for pulmonary valve replacement (PVR). Furthermore, unfavorable anatomy often precludes transcatheter PVR in patients with congenital heart disease. We therefore sought to evaluate the feasibility of the Edwards Inspiris pericardial aortic bioprosthesis in the pulmonary position in pediatric and adult patients requiring PVR. METHODS Data from consecutive patients who underwent PVR from February 2019 to February 2021 at our institution were retrospectively reviewed. Postoperative adverse events included paravalvular or transvalvular leak, endocarditis, explant, thromboembolism, valve thrombosis, valve-related bleeding, hemolysis, and structural valve degeneration. Progression of valve gradients was assessed from discharge to 30 days and one year. RESULTS Of 24 patients with median age of 26 years (interquartile range [IQR]: 17-33; range: 4-60 years), 22 (91.7%) patients had previously undergone tetralogy of Fallot repair and 2 (8.3%) patients had undergone double-outlet right ventricle repair in the neonatal period or infancy. All patients had at least mild right ventricular (RV) dilatation (median RV end-diastolic volume index 161.4, IQR: 152.3-183.5 mL/m2) and at least moderate pulmonary insufficiency (95.8%) or stenosis (8.3%). Median cardiopulmonary bypass and cross-clamp times were 71 (IQR: 63-101) min and 66 (IQR: 60-114) min, respectively. At a median postoperative follow-up of 2.5 years (IQR: 1.4-2.6; range: 1.0-3.0 years), there were no mortalities, valve-related reoperations, or adverse events. Postoperative valve gradients and the severity of pulmonary regurgitation did not change significantly over time. CONCLUSIONS At short-term follow-up, the bioprosthesis in this study demonstrated excellent safety and effectiveness for PVR. Further studies with longer follow-up are warranted.
Collapse
|
63
|
Amir G, Lowenthal A, Bruckheimer E, Dagan T, Schiller O, Shostak E, Frenkel G, Birk E. Three-Patch Reconstruction of Hourglass Supravalvar Pulmonary Artery Stenosis Mid-Term Results. World J Pediatr Congenit Heart Surg 2024; 15:89-93. [PMID: 37853700 DOI: 10.1177/21501351231196485] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2023]
Abstract
BACKGROUND Some patients with pulmonary stenosis present with a complex multilevel disease that involves the valve, the leaflets, and the sinotubular junction (STJ) forming an hourglass appearance. We herein report the mid-term results of our experience with the reconstruction of the supravalvar narrowing using three pericardial patches. MATERIAL AND METHODS Retrospective analysis of patient charts and echocardiography studies of patients who underwent three-patch reconstruction of the pulmonary valve (PV) from 2013 to 2022. After PV transection distal to STJ, vertical incisions into the sinuses were performed, and leaflets were trimmed and thinned. The three sinuses were augmented using three pericardial patches. RESULTS Nineteen patients underwent repair of hourglass supravalvar pulmonary stenosis. Mean weight at surgery was 9.4 kg (median 7.2, range 4.7-35); 16 patients underwent previous catheterization with unsuccessful balloon dilatation of the PV (13 pts.). Preoperative aortic/pulmonary annulus ratio was 1.02 (median 1, range 0.89-1.25). After surgery, gradients across the PV were significantly reduced (94 ± 26 vs 29 ± 9 mm Hg, P = .02). Postoperatively, 14 patients had mild or no pulmonary insufficiency (PI) and five had mild to moderate PI. At a mean follow-up of 71 months (median 78 months, range 8-137), gradients continued to decrease (29 ± 9 vs 15 ± 5 mm Hg, P < .001). CONCLUSION The three-patch technique for the repair of supravalvar pulmonary stenosis is simple, reproducible, and achieves excellent and long-standing relief of the right ventricular outflow tract gradient.
Collapse
|
64
|
Pilati M, Duong P, Bordonaro V, Secinaro A, Butera G. Auto-expandable pulmonary valve leaflet microthrombosis: a subtle and dangerous phenomenon. Eur Heart J Cardiovasc Imaging 2023; 25:e56. [PMID: 37846659 PMCID: PMC10735289 DOI: 10.1093/ehjci/jead260] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Accepted: 10/06/2023] [Indexed: 10/18/2023] Open
|
65
|
Gil-Jaurena JM, Pardo C, Pita A, Perez-Caballero R. Left axillary approach for pulmonary valve replacement. Multimed Man Cardiothorac Surg 2023; 2023. [PMID: 38108603 DOI: 10.1510/mmcts.2023.096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2023]
Abstract
A 14-year-old girl was scheduled for pulmonary valve replacement. A computed tomography scan showed an enlarged cardiac silhouette with an aneurysmal pulmonary artery. A less-invasive approach through the left axilla with peripheral cannulation was selected. The patient was draped in the decubitus position, with a roll under the left shoulder and the left arm over the head. The anatomical landmarks were the left nipple and the tip of the scapula. A 5-cm vertical incision in the mid-axillary line was performed, and the thorax was entered through the fourth intercostal space. Peripheral cannulation for cardiopulmonary bypass was achieved by a right groin dissection. Partial bypass was instituted and, on an unloaded heart, the ascending aorta plus the right appendage and the pulmonary artery were further cannulated. With the heart beating, the pulmonary artery was opened, and a 25-mm biological Carpentier Perimount-Magna valve was chosen. A second stitch was used to close the arteriotomy with large bites in a double row to reduce the perimeter of the trunk. Cardiopulmonary bypass was discontinued (after 64 minutes), and the cannulas were removed sequentially. Echocardiography showed a good result, with proper valve function and a reduced pulmonary artery. The patient was discharged on postoperative day 12 on antiplatelet therapy.
Collapse
|
66
|
Perri G, Galletti L. [Is there still role for the Ross procedure?]. GIORNALE ITALIANO DI CARDIOLOGIA (2006) 2023; 24:960-964. [PMID: 38009348 DOI: 10.1714/4139.41342] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 11/28/2023]
Abstract
The ideal aortic valve substitute for young and middle-aged adults with aortic valve disease is still debated. The Ross procedure (pulmonary autograft replacement) is the only operation that allows replacement of the diseased aortic valve with a living substitute. During the years, the use of this procedure has declined significantly due to concerns over increased intraoperative risk and especially potential long-term failure of the operation. However, several recent publications have shown that, after appropriate learning curve and in specialized centers, the Ross procedure can be performed safely in appropriately selected patients. Moreover, comparative studies suggest that the Ross procedure is associated with better long-term outcomes compared to conventional aortic valve replacement in young and middle-aged adults.
Collapse
|
67
|
Vervenne T, Maes L, Van Hoof L, Rega F, Famaey N. Drivers of vascular growth and remodeling: A computational framework to promote benign adaptation in the Ross procedure. J Mech Behav Biomed Mater 2023; 148:106170. [PMID: 37852088 DOI: 10.1016/j.jmbbm.2023.106170] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Revised: 10/04/2023] [Accepted: 10/09/2023] [Indexed: 10/20/2023]
Abstract
In the sixties, Dr Donald Ross designed a surgical solution for young patients with aortic valve disease by using the patients' own pulmonary valve. The Ross procedure is the only aortic valve replacement technique that can restore long-term survival and preserve quality of life. The main failure mode of the Ross procedure is wall dilatation, potentially leading to valve regurgitation and leakage. Dilatation occurs due to the inability of the pulmonary autograft to adapt to the sudden increase in loading when exposing to aortic pressures. Previous experimental data has shown that a permanent external support wrapped around the artery can prevent the acute dilatation of the arterial wall. However, the textile support leads to stress-shielding phenomena due to the loss of mechanical wall compliance. We present a pragmatic and modular computational framework of arterial growth and remodeling predicting the long-term outcomes of cardiovascular tissue adaptation, with and without textile wrapping. The model integrates mean, systolic and diastolic pressures and assumes the resulting wall stresses to drive the biological remodeling rules. Rather than a single mean pressure or stress deviation from the homeostatic state, we demonstrate that only pulsatile stresses can predict available experimental results. Therefore, we suggest that a biodegradable external support could induce benign remodeling in the Ross procedure. Indeed, a biodegradable textile wrapped around the autograft fulfills the trade-off between prevention of acute dilatation on the one hand and recovery of arterial wall compliance on the other hand. After further validation, the computational framework can set the basis for the development of an actual biodegradable external support for the Ross procedure with optimized polymer mechanical properties and degradation behavior.
Collapse
|
68
|
Bou Chaaya RG, Barron E, Herrmann JL, Brown JW, Ephrem G. QRS Duration After Pulmonary Valve Replacement in Adults with Repaired Tetralogy of Fallot: Association with Ventricular Arrhythmia and Correlation with Right Ventricular Size. Pediatr Cardiol 2023; 44:1658-1666. [PMID: 37624409 DOI: 10.1007/s00246-023-03272-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/13/2023] [Accepted: 08/09/2023] [Indexed: 08/26/2023]
Abstract
The aim of this study is to analyze the relationship between QRS duration after pulmonary valve replacement (PVR) and ventricular arrhythmias (VA) in patients with repaired tetralogy of Fallot (ToF). ToF patients may face complications such as heart failure and VA after primary repair, often mitigated by PVR. Prior studies have shown a decrease in QRS duration and right ventricular (RV) size following PVR. It remains unclear whether a lack of QRS duration reduction identifies patients at risk of VA. We retrospectively identified adult patients with repaired ToF who underwent surgical or transcatheter PVR. EKG data (pre-PVR, 30 days to 1-year post-PVR, and closest to CMR) was collected. The primary endpoint was sustained ventricular tachycardia (VT), ICD shock for sustained VT, or inducible VT on EP study. 85 patients were included (median follow-up 3.6 years; median age 34 years; 51% females). The primary outcome was noted in 8 patients. Mean QRS duration decreased by 5 ms following PVR (p = 0.0001). Increased age at PVR, QRS ≥ 180 ms post-PVR, no reduction in QRS after PVR, and a history of VT were associated with higher risk of the primary endpoint. The change in QRS was linearly correlated with the change in RVEDVi (R = 0.66). Adults with repaired ToF experience a reduction in QRS duration post-PVR that correlates with the change of the RV size. Patients with QRS ≥ 180 ms post-PVR, no reduction in QRS, increased age at repair, and a history of VT are at risk for recurrent VT and warrant closer monitoring/ICD consideration.
Collapse
|
69
|
Henmi S, Ryan JA, Mehta R, Haverty MC, Hovis IW, Puente BN, Ozturk M, Desai M, Tongut A, Yerebakan C, d'Udekem Y. A uniform strategy of primary repair of tetralogy of Fallot: Transventricular approach results in low reoperation rate in the first decade. J Thorac Cardiovasc Surg 2023; 166:1731-1738.e3. [PMID: 37301251 DOI: 10.1016/j.jtcvs.2023.05.036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Revised: 04/27/2023] [Accepted: 05/30/2023] [Indexed: 06/12/2023]
Abstract
OBJECTIVES To review outcomes after a uniform strategy of transventricular repair of tetralogy of Fallot. METHODS A total of 244 consecutive patients underwent transventricular primary repair of tetralogy of Fallot from 2004 to 2019. Median age at operation was 71 days; 57 (23%) patients were premature; 57 (23%) patients had low birth weight (<2.5 kg), and 40 (16%) had genetic syndromes. The diameter of pulmonary valve annulus, right pulmonary artery (PA), and left PA were 6.0 ± 1.8 mm (z score, -1.7 ± 1.3), 4.3 ± 1.4 mm (z score, -0.9 ± 1.2) and 4.1 ± 1.5 mm (z score, -0.5 ± 1.3). RESULTS Three (1.2%) operative deaths were recorded. Ninety patients (37%) underwent transannular patching. Postoperative echocardiographic peak right ventricular outflow tract gradient decreased from 72 ± 27 mm Hg to 21 ± 16 mm Hg. Median intensive care unit and hospital stay were 3 and 7 days. The survival rate at 10 years was 94.6% ± 1.8%. Reintervention was required 86 times (55 catheter interventions) in 56 patients following tetralogy of Fallot repair. The freedom from all-cause reintervention rate at 10 years was 70.5% ± 3.6%. Cyanotic spells (hazard ratio, 2.14; 95% CI, 1.22-3.90; P < .01) and smaller pulmonary valve annulus z score (hazard ratio, 1.26; 95% CI, 1.01-1.59; P = .04) were associated with increasing risk of all reinterventions. Freedom from redo surgery for right ventricular outflow tract obstruction and right ventricular dilatation at 10 years were, respectively, 85.0% ± 3.1% and 98.7% ± 0.9%. Freedom from valve implantation was 96.7% ± 1.5% at 10 years. CONCLUSIONS A uniform strategy of primary repair of tetralogy of Fallot through a transventricular approach resulted in low reoperation rate in the first decade. The need of pulmonary valve implantation was limited to <4% at 10 years.
Collapse
|
70
|
Wada T, Nagashima R, Kizu K, Takayama T, Miyamoto S, Sako H. Totally endoscopic pulmonary valve replacement. MINIM INVASIV THER 2023; 32:345-347. [PMID: 37729442 DOI: 10.1080/13645706.2023.2250422] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Accepted: 08/14/2023] [Indexed: 09/22/2023]
Abstract
A 68-year-old man with a history of valve-sparing aortic root replacement and endoscopic aortic valve replacement was admitted to our hospital with dyspnea. Transthoracic echocardiography revealed severe pulmonary valve regurgitation. The patient had undergone cardiac surgery twice, through median sternotomy and right thoracotomy; therefore, we planned endoscopic pulmonary valve replacement via the left thoracic approach. The patient was placed in a modified right lateral decubitus position and underwent mild hypothermic cardiopulmonary bypass. An on-pump beating-heart technique was used during surgery. The 3D endoscopic system and trocars for surgical instruments were inserted through the left 3rd and 4th intercostal spaces. After incision of the pulmonary artery, the pulmonary cusps were resected. A 27-mm St Jude Medical Epic heart valve was implanted in the intra-annular position. Subsequently, the left atrial appendage was resected. The patient was discharged without complications. To our knowledge, this is the first case of totally endoscopic pulmonary valve replacement.
Collapse
|
71
|
Al Kindi HN, Kaabi SA, Al Harthi H, Al Harthi T, Al Habsi A, Kandachar P. Pulmonary Annulus Growth Pattern in Patients with Tetralogy of Fallot Prior to Surgical Repair. Sultan Qaboos Univ Med J 2023; 23:31-37. [PMID: 38161756 PMCID: PMC10754307 DOI: 10.18295/squmj.12.2023.077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2023] [Revised: 10/14/2023] [Accepted: 11/14/2023] [Indexed: 01/03/2024] Open
Abstract
Objectives The size of the pulmonary valve annulus often determines the feasibility of pulmonary valve preservation at the time of intracardiac repair of Tetralogy of Fallot. Currently, there is limited available data regarding the growth pattern and the determining factors that contribute towards pulmonary valve annulus growth. Methods This retrospective study included patients who underwent surgical repair of Tetralogy of Fallot with or without prior palliation. These patients had an echocardiogram at the time of initial diagnosis and a second echocardiogram prior to intracardiac repair. The sizes of the pulmonary annulus, the right and left pulmonary arteries with z-scores were recorded. Patients with improvement in the pulmonary annulus z-scores between the 2 echocardiographic examinations were allocated in Group I (n = 46) and Group II (n = 68) were those with no improvement. Results A total of 114 patients were included in the study. The right and left pulmonary arteries size and z scores improved significantly between the 2 echocardiograms. Although the median size of the pulmonary annulus increased between the 2 echocardiograms (6 and 7.9 mm; P<0.001), there was no significant change in the z-score (-2.2, -2.34; P = 0.185). Multivariate logistic regression analysis showed that gender, blood group, presence of collaterals, and palliation with Blalock-Taussig shunt had no impact on the improvement in pulmonary annulus z-score. Conclusion In Tetralogy of Fallot, the pulmonary valve annulus z-score may not change significantly prior to the intracardiac repair. Although in certain subgroups there may be an improvement, there was no specific factor that could be identified and had an influence on this improvement.
Collapse
|
72
|
Góreczny S, Szeliga J, Lazu M, Załuska-Pitak B, Gewillig M. First Polish pediatric experience with percutaneous self-expandable pulmonary valve implantation. Kardiol Pol 2023; 82:101-102. [PMID: 37997834 DOI: 10.33963/v.kp.97724] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Accepted: 10/05/2023] [Indexed: 11/25/2023]
|
73
|
Voges I, Krupickova S. Transcatheter Pulmonary Valve Replacement Candidacy: Is Cardiovascular Magnetic Resonance Angiography Enough? Am J Cardiol 2023; 207:507-508. [PMID: 37802700 DOI: 10.1016/j.amjcard.2023.09.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Accepted: 09/06/2023] [Indexed: 10/08/2023]
|
74
|
Irwin M, Reynolds L, Binney G, Lipsitz S, Ghelani SJ, Harrild DM, Baird CW, Geva T, Brown DW. Right Heart Remodeling After Pulmonary Valve Replacement in Patients With Pulmonary Atresia or Critical Stenosis With Intact Ventricular Septum. J Am Heart Assoc 2023; 12:e031090. [PMID: 37929755 PMCID: PMC10727386 DOI: 10.1161/jaha.123.031090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Accepted: 09/28/2023] [Indexed: 11/07/2023]
Abstract
Background Patients with pulmonary atresia or critical pulmonary stenosis with intact ventricular septum (PA/IVS) and biventricular circulation may require pulmonary valve replacement (PVR). Right ventricular (RV) remodeling after PVR is well described in tetralogy of Fallot (TOF); we sought to investigate RV changes in PA/IVS using cardiac magnetic resonance imaging. Methods and Results A retrospective cohort of patients with PA/IVS who underwent PVR at Boston Children's Hospital from 1995 to 2021 with cardiac magnetic resonance imaging before and after PVR was matched 1:3 with patients with TOF by age at PVR. Median regression modeling was performed with post-PVR indexed RV end-diastolic volume as the primary outcome. A total of 20 patients with PA/IVS (cases) were matched with 60 patients with TOF (controls), with median age at PVR of 14 years. Pre-PVR indexed RV end-diastolic volume was similar between groups; cases had higher RV ejection fraction (51.4% versus 48.6%; P=0.03). Pre-PVR RV free wall and left ventricular (LV) longitudinal strain were similar, although LV midcavity circumferential strain was decreased in cases (-15.6 versus -17.1; P=0.001). At a median of 2 years after PVR, indexed RV end-diastolic volume was similarly reduced; cases continued to have higher RV ejection fraction (52.3% versus 46.9%; P=0.007) with less reduction in RV mass (Δ4.5 versus 9.6 g/m2; P=0.004). Post-PVR, RV and LV longitudinal strain remained unchanged, and LV circumferential strain was similar, although lower in cases. Conclusions Compared with patients with TOF, patients with PA/IVS demonstrate similar RV remodeling after PVR, with lower reduction in RV mass and comparatively higher RV ejection fraction. Although no differences were detected in peak systolic RV or LV strain values, further investigation of diastolic parameters is needed.
Collapse
|
75
|
Yacoub MH, Notenboom ML, Melina G, Takkenberg JJM. Surgical Heritage: You Had to Be There, Ross: The Comeback Kid. Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu 2023; 27:37-41. [PMID: 38522870 DOI: 10.1053/j.pcsu.2023.10.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Revised: 10/30/2023] [Accepted: 10/30/2023] [Indexed: 03/26/2024]
Abstract
Half a century after the first pulmonary autograft operation (Ross operation), performed in 1967 by Donald Ross in central London, there is a very strong conviction that the Ross operation is the best available valve substitute today, not only for children, but also for younger and older adults. The Ross operation has stimulated a lot of science to do with tissue-engineering and biology of heart valves, which is a promising avenue for the future. For one of us (M.Y.), it has certainly been a privilege to be associated with the comeback of the Ross operation.
Collapse
|