76
|
Zobel K, Choi SE, Minakova R, Gocyla M, Offenhäusser A. N-Cadherin modified lipid bilayers promote neural network formation and circuitry. SOFT MATTER 2017; 13:8096-8107. [PMID: 29085948 DOI: 10.1039/c7sm01214d] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Neural adhesion, maturation, and the correct wiring of the brain to establish each neuron's intended connectivity are controlled by complex interactions of bioactive molecules such as ligands, growth factors, or enzymes. The correct pairing of adjacent neurons is thought to be highly regulated by ligand-mediated cell-cell adhesion proteins, which are known to induce signaling activities. We developed a new platform consisting of supported lipid bilayers incorporated with Fc-chimera synaptic proteins like ephrinA5 or N-cadherin. We extensively characterized their function employing a quartz crystal microbalance with dissipation (QCM-D), calcium imaging, and immunofluorescence analysis. Our biomimetic platform has been shown to promote neural cell adhesion and to improve neural maturation at day in vitro 7 (DIV7) as indicated by an elevated expression of synaptophysin.
Collapse
|
77
|
Fu W, Feng L, Panaitov G, Kireev D, Mayer D, Offenhäusser A, Krause HJ. Biosensing near the neutrality point of graphene. SCIENCE ADVANCES 2017; 3:e1701247. [PMID: 29075669 PMCID: PMC5656418 DOI: 10.1126/sciadv.1701247] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2017] [Accepted: 09/26/2017] [Indexed: 05/05/2023]
Abstract
Over the past decade, the richness of electronic properties of graphene has attracted enormous interest for electrically detecting chemical and biological species using this two-dimensional material. However, the creation of practical graphene electronic sensors greatly depends on our ability to understand and maintain a low level of electronic noise, the fundamental reason limiting the sensor resolution. Conventionally, to reach the largest sensing response, graphene transistors are operated at the point of maximum transconductance, where 1/f noise is found to be unfavorably high and poses a major limitation in any attempt to further improve the device sensitivity. We show that operating a graphene transistor in an ambipolar mode near its neutrality point can markedly reduce the 1/f noise in graphene. Remarkably, our data reveal that this reduction in the electronic noise is achieved with uncompromised sensing response of the graphene chips and thus significantly improving the signal-to-noise ratio-compared to that of a conventionally operated graphene transistor for conductance measurement. As a proof-of-concept demonstration of the usage of the aforementioned new sensing scheme to a broader range of biochemical sensing applications, we selected an HIV-related DNA hybridization as the test bed and achieved detections at picomolar concentrations.
Collapse
|
78
|
Adly NY, Hassani H, Tran AQ, Balski M, Yakushenko A, Offenhäusser A, Mayer D, Wolfrum B. Observation of chemically protected polydimethylsiloxane: towards crack-free PDMS. SOFT MATTER 2017; 13:6297-6303. [PMID: 28920620 DOI: 10.1039/c7sm01457k] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The current modification of polydimethylsiloxane (PDMS) substrates via oxygen plasma treatment causes surface cracks. Here, we demonstrate a method to prevent crack formation by chemical treatment. Chemical modification renders the surface hydrophilic for several days and is effective in preserving the elasticity of the PDMS surface at the nanoscale level.
Collapse
|
79
|
Markov A, Wolf N, Yuan X, Mayer D, Maybeck V, Offenhäusser A, Wördenweber R. Controlled Engineering of Oxide Surfaces for Bioelectronics Applications Using Organic Mixed Monolayers. ACS APPLIED MATERIALS & INTERFACES 2017; 9:29265-29272. [PMID: 28783310 DOI: 10.1021/acsami.7b08481] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Modifying the surfaces of oxides using self-assembled monolayers offers an exciting possibility to tailor their surface properties for various applications ranging from organic electronics to bioelectronics applications. The simultaneous use of different molecules in particular can extend this approach because the surface properties can be tuned via the ratio of the chosen molecules. This requires the composition and quality of the monolayers to be controlled on an organic level, that is, on the nanoscale. In this paper, we present a method of modifying the surface and surface properties of silicon oxide by growing self-assembled monolayers comprising various compositions of two different molecules, (3-aminopropyl)-triethoxysilane and (3-glycidyloxypropyl)-trimethoxysilane, by means of in situ controlled gas-phase deposition. The properties of the resulting mixed molecular monolayers (e.g., effective thickness, hydrophobicity, and surface potential) exhibit a perfect linear dependence on the composition of the molecular layer. Finally, coating the mixed layer with poly(l-lysine) proves that the density of proteins can be controlled by the composition as well. This indicates that the method might be an ideal way to optimize inorganic surfaces for bioelectronics applications.
Collapse
|
80
|
Kireev D, Seyock S, Lewen J, Maybeck V, Wolfrum B, Offenhäusser A. Graphene Multielectrode Arrays as a Versatile Tool for Extracellular Measurements. Adv Healthc Mater 2017; 6. [PMID: 28371490 DOI: 10.1002/adhm.201601433] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2016] [Revised: 02/05/2017] [Indexed: 11/12/2022]
Abstract
Graphene multielectrode arrays (GMEAs) presented in this work are used for cardio and neuronal extracellular recordings. The advantages of the graphene as a part of the multielectrode arrays are numerous: from a general flexibility and biocompatibility to the unique electronic properties of graphene. The devices used for extensive in vitro studies of a cardiac-like cell line and cortical neuronal networks show excellent ability to extracellularly detect action potentials with signal to noise ratios in the range of 45 ± 22 for HL-1 cells and 48 ± 26 for spontaneous bursting/spiking neuronal activity. Complex neuronal bursting activity patterns as well as a variety of characteristic shapes of HL-1 action potentials are recorded with the GMEAs. This paper illustrates that the potential applications of the GMEAs in biological and medical research are still numerous and diverse.
Collapse
|
81
|
Toma M, Belu A, Mayer D, Offenhäusser A. Flexible Gold Nanocone Array Surfaces as a Tool for Regulating Neuronal Behavior. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2017; 13:1700629. [PMID: 28464550 DOI: 10.1002/smll.201700629] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/24/2017] [Indexed: 05/20/2023]
Abstract
Accelerated neurite outgrowth of rat cortical neurons on a flexible and inexpensive substrate functionalized with gold nanocone arrays is reported. The gold nanocone arrays are fabricated on Teflon films by a bottom-up approach based on colloidal lithography followed by deposition of a thin gold layer. The geometry of nanocone arrays including height and pitch is controlled by the overall etching time and template polystyrene beads size. Fluorescence microscopy studies reveal high viability and significant morphological changes of the neurons on the structured surfaces. The elongation degree of neurite is maximized on the nanocone arrays created with 1 µm polystyrene beads by a factor of two with respect to the control. Furthermore, the interface between the neurons and the nanocones is investigated by scanning electron microscopy and focused ion beam cross-sectioning. The detailed observation of the neuron/nanocone interfaces reveals the morphological similarity between the nanocone tips and the neuronal processes, the existence of interspace at the interface between the cell body and the nanocones, and neurite bridging among the neighboring structures, which may induce the acceleration of neurite outgrowth. The flexible gold nanocone arrays can be a good supporting substrate of neuron culture with noble electrical and optical properties.
Collapse
|
82
|
Bilatto SER, Adly NY, Correa DS, Wolfrum B, Offenhäusser A, Yakushenko A. Printed microfluidic filter for heparinized blood. BIOMICROFLUIDICS 2017; 11:034101. [PMID: 28798855 PMCID: PMC5533500 DOI: 10.1063/1.4982963] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2016] [Accepted: 04/24/2017] [Indexed: 05/25/2023]
Abstract
A simple lab-on-a-chip method for blood plasma separation was developed by combining stereolithographic 3D printing with inkjet printing, creating a completely sealed microfluidic device. In some approaches, one dilutes the blood sample before separation, reducing the concentration of a target analyte and increasing a contamination risk. In this work, a single drop (8 μl) of heparinized whole blood could be efficiently filtered using a capillary effect without any external driving forces and without dilution. The blood storage in heparin tubes during 24 h at 4 °C initiated the formation of small crystals that formed auto-filtration structures in the sample upon entering the 3D-printed device, with pores smaller than the red blood cells, separating plasma from the cellular content. The total filtration process took less than 10 s. The presented printed plasma filtration microfluidics fabricated with a rapid prototyping approach is a miniaturized, fast and easy-to-operate device that can be integrated into healthcare/portable systems for point-of-care diagnostics.
Collapse
|
83
|
Nikolaev KG, Ermakov SS, Offenhäusser A, Mourzina Y. Nonenzymatic determination of glucose on electrodes prepared by directed electrochemical nanowire assembly (DENA). JOURNAL OF ANALYTICAL CHEMISTRY 2017. [DOI: 10.1134/s1061934817040104] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
84
|
Grellmann T, Mayer D, Offenhäusser A, Wördenweber R. Temperature-Dependent Electron Transport in Single Terphenyldithiol Molecules. J Phys Chem A 2017; 121:2911-2917. [PMID: 28375607 DOI: 10.1021/acs.jpca.7b00977] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Analyzing the electronic properties of individual terphenyldithiol (TPT) molecules in a temperature range of 30-300 K using cryogenic mechanically controllable break junctions, we observe an unexpected change of the transport mechanism with temperature for this linear and symmetric aromatic molecule. Whereas the work function (∼3.8 eV) and molecular energy level (∼0.8 to ∼1 eV depending on the analysis of the data) of TPT are temperature-independent, elastic tunneling dominates charge transport at low temperatures, whereby an inelastic transport (via hopping) sets in at about 100 K. The molecular level of TPT lies around 1 eV and is temperature-independent. This unusual temperature dependence agrees with recent predictions for other short molecules using density-functional-based transport studies as well as experimental observations obtained for similar relatively short rodlike molecules.
Collapse
|
85
|
Krause KJ, Brings F, Schnitker J, Kätelhön E, Rinklin P, Mayer D, Compton RG, Lemay SG, Offenhäusser A, Wolfrum B. The Influence of Supporting Ions on the Electrochemical Detection of Individual Silver Nanoparticles: Understanding the Shape and Frequency of Current Transients in Nano-impacts. Chemistry 2017; 23:4638-4643. [DOI: 10.1002/chem.201605924] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2016] [Indexed: 01/01/2023]
|
86
|
Rosen YS, Yakushenko A, Offenhäusser A, Magdassi S. Self-Reducing Copper Precursor Inks and Photonic Additive Yield Conductive Patterns under Intense Pulsed Light. ACS OMEGA 2017; 2:573-581. [PMID: 31457455 PMCID: PMC6641306 DOI: 10.1021/acsomega.6b00478] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/07/2016] [Accepted: 02/03/2017] [Indexed: 06/10/2023]
Abstract
Printing conducting copper interconnections on plastic substrates is of growing interest in the field of printed electronics. Photonic curing of copper inks with intense pulsed light (IPL) is a promising process as it is very fast and thus can be incorporated in roll-to-roll production. We report on using IPL for obtaining conductive patterns from inks composed of submicron particles of copper formate, a copper precursor that has a self-reduction property. Decomposition of copper formate can be performed by IPL and is affected both by the mode of energy application and the properties of the printed precursor layer. The energy application mode was controlled by altering three pulse parameters: duration, intensity, and repetitions at 1 Hz. As the decomposition results from energy transfer via light absorption, carbon nanotubes (CNTs) were added to the ink to increase the absorbance. We show that there is a strict set of IPL parameters necessary to obtain conductive copper patterns. Finally, we show that by adding as little as 0.5 wt % single-wall CNTs to the ink the absorptance was enhanced by about 50% and the threshold energy required to obtain a conductive pattern decreased by ∼25%. These results have major implications for tailoring inks intended for IPL processing.
Collapse
|
87
|
Adly N, Feng L, Krause KJ, Mayer D, Yakushenko A, Offenhäusser A, Wolfrum B. Flexible Microgap Electrodes by Direct Inkjet Printing for Biosensing Application. ACTA ACUST UNITED AC 2017. [DOI: 10.1002/adbi.201600016] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
88
|
Weidlich S, Krause KJ, Schnitker J, Wolfrum B, Offenhäusser A. MEAs and 3D nanoelectrodes: electrodeposition as tool for a precisely controlled nanofabrication. NANOTECHNOLOGY 2017; 28:095302. [PMID: 28139471 DOI: 10.1088/1361-6528/aa57b5] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Microelectrode arrays (MEAs) are gaining increasing importance for the investigation of signaling processes between electrogenic cells. However, efficient cell-chip coupling for robust and long-term electrophysiological recording and stimulation still remains a challenge. A possible approach for the improvement of the cell-electrode contact is the utilization of three-dimensional structures. In recent years, various 3D electrode geometries have been developed, but we are still lacking a fabrication approach that enables the formation of different 3D structures on a single chip in a controlled manner. This, however, is needed to enable a direct and reliable comparison of the recording capabilities of the different structures. Here, we present a method for a precisely controlled deposition of nanoelectrodes, enabling the fabrication of multiple, well-defined types of structures on our 64 electrode MEAs towards a rapid-prototyping approach to 3D electrodes.
Collapse
|
89
|
Tran AQ, Kaulen C, Simon U, Offenhäusser A, Mayer D. Surface coupling strength of gold nanoparticles affects cytotoxicity towards neurons. Biomater Sci 2017; 5:1051-1060. [DOI: 10.1039/c7bm00054e] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Weakly bound gold nanoparticles reveal awful toxicity towards neurons.
Collapse
|
90
|
Seyock S, Maybeck V, Scorsone E, Rousseau L, Hébert C, Lissorgues G, Bergonzo P, Offenhäusser A. Interfacing neurons on carbon nanotubes covered with diamond. RSC Adv 2017. [DOI: 10.1039/c6ra20207a] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Investigation of the interface and needed adhesion surface for neuronal cells on carbon nanotubes covered with diamond.
Collapse
|
91
|
Adly NY, Bachmann B, Krause KJ, Offenhäusser A, Wolfrum B, Yakushenko A. Three-dimensional inkjet-printed redox cycling sensor. RSC Adv 2017. [DOI: 10.1039/c6ra27170g] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Electrochemical amplification through redox cycling in an all-inkjet-printed device utilizing four different functional inks.
Collapse
|
92
|
Seyock S, Maybeck V, Offenhäusser A. How to image cell adhesion on soft polymers? Micron 2016; 92:39-42. [PMID: 27866099 DOI: 10.1016/j.micron.2016.11.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2016] [Revised: 11/07/2016] [Accepted: 11/07/2016] [Indexed: 11/25/2022]
Abstract
Here, we present a method to investigate cell adhesion on soft, non-conducting polymers that are implant candidate materials. Neuronal cells were grown on two elastomers (polydimethylsiloxane (PDMS) and Ecoflex®) and prepared for electron microscopy. The samples were treated with osmium tetroxide (OsO4) and uranylacetate (UrAc). Best results can be achieved when the polymers were coated with a thin iridium layer before the cell culture. This was done to emphasize the usage of soft polymers as supports for implant electrodes. A good contrast and the adhesion of the cells on soft polymers could be visualized.
Collapse
|
93
|
Maybeck V, Schnitker J, Li W, Heuschkel M, Offenhäusser A. An evaluation of extracellular MEA versus optogenetic stimulation of cortical neurons. Biomed Phys Eng Express 2016. [DOI: 10.1088/2057-1976/2/5/055017] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
94
|
Jin L, Lange W, Kempmann A, Maybeck V, Günther A, Gruteser N, Baumann A, Offenhäusser A. High-efficiency transduction and specific expression of ChR2opt for optogenetic manipulation of primary cortical neurons mediated by recombinant adeno-associated viruses. J Biotechnol 2016; 233:171-80. [DOI: 10.1016/j.jbiotec.2016.07.001] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2016] [Revised: 06/29/2016] [Accepted: 07/01/2016] [Indexed: 10/21/2022]
|
95
|
Chen L, Li W, Maybeck V, Offenhäusser A, Krause HJ. Statistical study of biomechanics of living brain cells during growth and maturation on artificial substrates. Biomaterials 2016; 106:240-9. [PMID: 27573132 DOI: 10.1016/j.biomaterials.2016.08.029] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2016] [Revised: 08/03/2016] [Accepted: 08/17/2016] [Indexed: 11/26/2022]
Abstract
There is increasing evidence that mechanical issues play a vital role in neuron growth and brain development. The importance of this grows as novel devices, whose material properties differ from cells, are increasingly implanted in the body. In this work, we studied the mechanical properties of rat brain cells over time and on different materials by using a high throughput magnetic tweezers system. It was found that the elastic moduli of both neurite and soma in networked neurons increased with growth. However, neurites at DIV4 exhibited a relatively high stiffness, which could be ascribed to the high outgrowth tension. The power-law exponents (viscoelasticity) of both neurites and somas of neurons decreased with culture time. On the other hand, the stiffness of glial cells also increased with maturity. Furthermore, both neurites and glia become softer when cultured on compliant substrates. Especially, the glial cells cultured on a soft substrate obviously showed a less dense and more porous actin and GFAP mesh. In addition, the viscoelasticity of both neurites and glia did not show a significant dependence on the substrates' stiffness.
Collapse
|
96
|
Funari R, Della Ventura B, Altucci C, Offenhäusser A, Mayer D, Velotta R. Single Molecule Characterization of UV-Activated Antibodies on Gold by Atomic Force Microscopy. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2016; 32:8084-91. [PMID: 27444884 DOI: 10.1021/acs.langmuir.6b02218] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
The interaction between proteins and solid surfaces can influence their conformation and therefore also their activity and affinity. These interactions are highly specific for the respective combination of proteins and solids. Consequently, it is desirable to investigate the conformation of proteins on technical surfaces, ideally at single molecule level, and to correlate the results with their activity. This is in particular true for biosensors where the conformation-dependent target affinity of an immobilized receptor determines the sensitivity of the sensor. Here, we investigate for the first time the immobilization and orientation of antibodies (Abs) photoactivated by a photonic immobilization technique (PIT), which has previously demonstrated to enhance binding capabilities of antibody receptors. The photoactivated immunoglobulins are immobilized on ultrasmooth template stripped gold films and investigated by atomic force microscopy (AFM) at the level of individual molecules. The observed protein orientations are compared with results of nonactivated antibodies adsorbed on similar gold films and mica reference samples. We find that the behavior of Abs is similar for mica and gold when the protein are not treated (physisorption), whereas smaller contact area and larger heights are measured when Abs are treated (PIT). This is explained by assuming that the activated antibodies tend to be more upright compared with nonirradiated ones, thereby providing a better exposure of the binding sites. This finding matches the observed enhancement of Abs binding efficiency when PIT is used to functionalize gold surface of QCM-based biosensors.
Collapse
|
97
|
Muratova IS, Mikhelson KN, Ermolenko Y, Offenhäusser A, Mourzina Y. On “resistance overpotential” caused by a potential drop along the ultrathin high aspect ratio gold nanowire electrodes in cyclic voltammetry. J Solid State Electrochem 2016. [DOI: 10.1007/s10008-016-3280-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
98
|
Markov A, Greben K, Mayer D, Offenhäusser A, Wördenweber R. In Situ Analysis of the Growth and Dielectric Properties of Organic Self-Assembled Monolayers: A Way To Tailor Organic Layers for Electronic Applications. ACS APPLIED MATERIALS & INTERFACES 2016; 8:16451-16456. [PMID: 27268402 DOI: 10.1021/acsami.6b04021] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Organic nanoscale science and technology relies on the control of phenomena occurring at the molecular level. This is of particular importance for the self-assembly of molecular monolayers (SAM) that can be used in various applications ranging from organic electronics to bioelectronic applications. However, the understanding of the elementary nanoscopic processes in molecular film growth is still in its infancy. Here, we developed a novel in situ and extremely sensitive detection method for the analysis of the electronic properties of molecular layer during molecular layer deposition. This low-frequency sensor (1 kHz) is employed to analyze the standard vapor deposition process of SAMs of molecules and, subsequently, it is used to optimize the growth process itself. By combining this method with an ex situ determination of the effective thickness of the resulting layers via ellipsometry, we observe a large difference of the permittivity (1 kHz) of the examined aminosilanes in the liquid state (εliquid = 5.5-8.8) and in SAMs (εSAM = 22-52, electric field in the plane of the layer). We ascribe this difference to either the different orientation and order of the molecules, the different density of molecules, or a combination of both effects. Our novel in situ analyses not only allows monitoring and optimizing the deposition of organic layers but also demonstrates the high potential of organic SAMs as organic high-k layers in electronic devices.
Collapse
|
99
|
Albers J, Offenhäusser A. Signal Propagation between Neuronal Populations Controlled by Micropatterning. Front Bioeng Biotechnol 2016; 4:46. [PMID: 27379230 PMCID: PMC4908115 DOI: 10.3389/fbioe.2016.00046] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2015] [Accepted: 05/20/2016] [Indexed: 11/13/2022] Open
Abstract
The central nervous system consists of an unfathomable number of functional networks enabling highly sophisticated information processing. Guided neuronal growth with a well-defined connectivity and accompanying polarity is essential for the formation of these networks. To investigate how two-dimensional protein patterns influence neuronal outgrowth with respect to connectivity and functional polarity between adjacent populations of neurons, a microstructured model system was established. Exclusive cell growth on patterned substrates was achieved by transferring a mixture of poly-l-lysine and laminin to a cell-repellent glass surface by microcontact printing. Triangular structures with different opening angle, height, and width were chosen as a pattern to achieve network formation with defined behavior at the junction of adjacent structures. These patterns were populated with dissociated primary cortical embryonic rat neurons and investigated with respect to their impact on neuronal outgrowth by immunofluorescence analysis, as well as their functional connectivity by calcium imaging. Here, we present a highly reproducible technique to devise neuronal networks in vitro with a predefined connectivity induced by the design of the gateway. Daisy-chained neuronal networks with predefined connectivity and functional polarity were produced using the presented micropatterning method. Controlling the direction of signal propagation among populations of neurons provides insights to network communication and offers the chance to investigate more about learning processes in networks by external manipulation of cells and signal cascades.
Collapse
|
100
|
Chen L, Maybeck V, Offenhäusser A, Krause HJ. Implementation and application of a novel 2D magnetic twisting cytometry based on multi-pole electromagnet. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:064301. [PMID: 27370475 DOI: 10.1063/1.4954185] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
We implemented a novel 2D magnetic twisting cytometry (MTC) based on a previously reported multi-pole high permeability electromagnet, in which both the strength and direction of the twisting field can be controlled. Thanks to the high performance twisting electromagnet and the heterodyning technology, the measurement frequency has been extended to the 1 kHz range. In order to obtain high remanence of the ferromagnetic beads, a separate electromagnet with feedback control was adopted for the high magnetic field polarization. Our setup constitutes the first instrument which can be operated both in MTC mode and in magnetic tweezers (MT) mode. In this work, the mechanical properties of HL-1 cardiomyocytes were characterized in MTC mode. Both anisotropy and log-normal distribution of cell stiffness were observed, which agree with our previous results measured in MT mode. The response from these living cells at different frequencies can be fitted very well by the soft glassy rheology model.
Collapse
|