151
|
Kim Y, Hsu I, Pouliot J. SU-FF-T-37: Measurement of Cranio-Caudal Catheter Displacement Between Fractions in CT-Based HDR Brachytherapy of Prostate Cancer. Med Phys 2005. [DOI: 10.1118/1.1997708] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
152
|
Aubin M, Morin O, Bucci K, Chen J, Roach M, Pouliot J. SU-FF-J-60: Effectiveness of MVCBCT for Patients with Implanted High-Z Material. Med Phys 2005. [DOI: 10.1118/1.1997606] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
153
|
Pouliot J, Bani-Hashemi A, Aubin M, Ghelmansarai F, Chen J, Morin O, Bucci K, Roach M, Verhey L. SU-FF-J-81: Clinical Integration of a MV Conebeam CT System for Image-Guided Treatment. Med Phys 2005. [DOI: 10.1118/1.1997627] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
154
|
Ghelmansarai F, Bani-Hashemi A, Pouliot J, Calderon E, Hernandez P, Mitschke M, Aubin M, Bucci K. WE-D-I-6B-01: Soft Tissue Visualization Using a Highly Efficient Megavoltage Cone Beam CT Imaging System. Med Phys 2005. [DOI: 10.1118/1.1998537] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
155
|
Chen J, Morin O, Chen H, Aubin M, Pouliot J. SU-FF-J-72: The Effect of MV Cone-Beam CT Cupping Artifacts On Dose Calculation Accuracy. Med Phys 2005. [DOI: 10.1118/1.1997618] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
156
|
Morin O, Bose S, Chen J, Aubin M, Pouliot J. SU-FF-I-53: The Impact of Portal Imager Shifts and the Assumption of Rigid Isocentricity On Megavoltage Cone Beam CT Images. Med Phys 2005. [DOI: 10.1118/1.1997533] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
157
|
Lometti M, Morin O, Aubin M, Gottschalk A, Pouliot J, Roach M. TH-C-J-6B-07: Intra-Fractional and Inter/Intra-Field Organ Motion and a Proposal for a New Patient Set-Up Protocol. Med Phys 2005. [DOI: 10.1118/1.1998651] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
158
|
Kwa S, Lessard E, Moerland M, Pouliot J. SU-FF-T-43: Objective Comparison of RAPID Strand and Free SelectSeeds Loading for Permanent Prostate Implants Using An Inverse Planning Approach. Med Phys 2005. [DOI: 10.1118/1.1997714] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
159
|
Huang K, Pouliot J, Lessard E, Weinberg V, Speight J, Chen L, Hsu I. Early clinical experience on inverse planned high dose rate interstitial brachytherapy in the treatment of locally advanced cervical cancer. Int J Radiat Oncol Biol Phys 2004. [DOI: 10.1016/j.ijrobp.2004.07.405] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
160
|
Mate T, Balter J, Wong J, Pouliot J, Starkschall G, Wright J, Dimmer S. Principles of ac magnetic fields for objective and continuous target localization in radiation therapy. Int J Radiat Oncol Biol Phys 2004. [DOI: 10.1016/j.ijrobp.2004.07.362] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
161
|
Lometti M, Thurston D, Aubin M, Verhey L, Lockhart J, Bland R, Roach M, Pouliot J. Are lateral electronic portal images adequate for accurate on-line daily targeting of the prostate? Results of a prospective study. Int J Radiat Oncol Biol Phys 2004. [DOI: 10.1016/j.ijrobp.2004.07.384] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
162
|
Menard C, Citrin D, Susil R, Ahmed Gharib P, Gustafson G, Ning H, Miller R, Ullman K, Guion P, Pouliot J, Coleman C, Camphausen K. 1.5T MRI for cathether placement and treatment planning in high dose rate brachytherapy for prostate cancer. Int J Radiat Oncol Biol Phys 2004. [DOI: 10.1016/j.ijrobp.2004.07.372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
163
|
Langen KM, Pouliot J, Anezinos C, Aubin M, Gottschalk AR, Hsu IC, Lowther D, Liu YM, Shinohara K, Verhey LJ, Weinberg V, Roach M. Evaluation of ultrasound-based prostate localization for image-guided radiotherapy. Int J Radiat Oncol Biol Phys 2003; 57:635-44. [PMID: 14529767 DOI: 10.1016/s0360-3016(03)00633-3] [Citation(s) in RCA: 197] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
To evaluate the use of the ultrasound-based BAT system for daily prostate alignment. Prostate alignments using the BAT system were compared with alignments using radiographic images of implanted radiopaque markers. The latter alignments were used as a reference. The difference between the BAT and marker alignments represents the displacements that would remain if the alignments were done using ultrasonography. The inter-user variability of the contour alignment process was assessed. On the basis of the marker alignments, the initial displacement of the prostate in the AP, superoinferior, and lateral direction was -0.9 +/- 3.9, 0.1 +/- 3.9, and 0.2 +/- 3.4 mm respectively. The directed differences between the BAT and marker alignments in the respective directions were 0.2 +/- 3.7, 2.7 +/- 3.9, and 1.6 +/- 3.1 mm. The occurrence of displacements >/=5 mm was reduced by a factor of two in the AP direction after the BAT system was used. Among eight users, the average range of couch shifts due to contour alignment variability was 7, 7, and 5 mm in the antero-posterior (AP), superoinferior, and lateral direction, respectively. In our study, the BAT alignments were systematically different from the marker alignments in the superoinferior, and lateral directions. The remaining random variability of the prostate position after the ultrasound-based alignment was similar to the initial variability. However, the occurrence of displacements >/=5 mm was reduced in the AP direction. The inter-user variation of the contour alignment process was significant.
Collapse
|
164
|
DeWitt K, Hsu I, Weinberg V, Lessard E, Pouliot J. 3-D inverse treatment planning and optimization for the tandem and ovoid applicator in cervical cancer. Int J Radiat Oncol Biol Phys 2003. [DOI: 10.1016/s0360-3016(03)01229-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
165
|
Pouliot J, Xia P, Aubin M, Verhey L, Bani-Hashemi A, Ghelmansarai F, Mitschke M, Svatos M. Low-dose megavoltage cone-beam CT for dose-guided radiation therapy. Int J Radiat Oncol Biol Phys 2003. [DOI: 10.1016/s0360-3016(03)00977-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
166
|
Mate T, Wong J, Wright J, Pouliot J, Dimmer S, Friemel B, Newell L, Silber A. Theory of operation for a system to perform objective, continuous target location tracking using non-ionizing energy. Int J Radiat Oncol Biol Phys 2003. [DOI: 10.1016/s0360-3016(03)01374-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
167
|
Aubin S, Beaulieu L, Pouliot S, Pouliot J, Roy R, Girouard LM, Martel-Brisson N, Vigneault E, Laverdière J. Robustness and precision of an automatic marker detection algorithm for online prostate daily targeting using a standard V-EPID. Med Phys 2003; 30:1825-32. [PMID: 12906201 DOI: 10.1118/1.1584041] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
An algorithm for the daily localization of the prostate using implanted markers and a standard video-based electronic portal imaging device (V-EPID) has been tested. Prior to planning, three gold markers were implanted in the prostate of seven patients. The clinical images were acquired with a BeamViewPlus 2.1 V-EPID for each field during the normal course radiotherapy treatment and are used off-line to determine the ability of the automatic marker detection algorithm to adequately and consistently detect the markers. Clinical images were obtained with various dose levels from ranging 2.5 to 75 MU. The algorithm is based on marker attenuation characterization in the portal image and spatial distribution. A total of 1182 clinical images were taken. The results show an average efficiency of 93% for the markers detected individually and 85% for the group of markers. This algorithm accomplishes the detection and validation in 0.20-0.40 s. When the center of mass of the group of implanted markers is used, then all displacements can be corrected to within 1.0 mm in 84% of the cases and within 1.5 mm in 97% of cases. The standard video-based EPID tested provides excellent marker detection capability even with low dose levels. The V-EPID can be used successfully with radiopaque markers and the automatic detection algorithm to track and correct the daily setup deviations due to organ motions.
Collapse
|
168
|
Downs T, Roach M, Grossfeld G, Langen K, Pouliot J, Aubin M, Pickett B, Carroll P, Shinohara K. The university of California, San Francisco (UCSF) experience with permanently implanted gold markers for daily prostate realignment during radiation therapy. Int J Radiat Oncol Biol Phys 2002. [DOI: 10.1016/s0360-3016(02)03542-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
169
|
Aubin M, Liu Y, Langen K, Shinohara K, Anezino C, Osofsky M, Weinberg V, Pouliot J, Roach M. Set-up verification using portal images of implanted prostate markers: an inter-observer study. Int J Radiat Oncol Biol Phys 2002. [DOI: 10.1016/s0360-3016(02)03522-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
170
|
Pouliot J, Charra-Brunaud C, Kim Y, Lessard E, Speight J, Xia P, Hsu I. Inverse planning for HDR brachytherapy: clinical implementation. Int J Radiat Oncol Biol Phys 2002. [DOI: 10.1016/s0360-3016(02)03631-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
171
|
Tubic D, Zaccarin A, Pouliot J, Beaulieu L. Automated seed detection and three-dimensional reconstruction. I. Seed localization from fluoroscopic images or radiographs. Med Phys 2001; 28:2265-71. [PMID: 11764031 DOI: 10.1118/1.1414308] [Citation(s) in RCA: 40] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
An automated procedure for the detection of the position and the orientation of radioactive seeds on fluoroscopic images or scanned radiographs is presented. The extracted positions of seed centers and the orientations are used for three-dimensional reconstruction of permanent prostate implants. The extraction procedure requires several steps: correction of image intensifier distortions, normalization, background removal, automatic threshold selection, thresholding, and finally, moment analysis and classification of the connected components. The algorithm was tested on 75 fluoroscopic images. The results show that, on average, 92% of the seeds are detected automatically. The orientation is found with an error smaller than 50 for 75% of the seeds. The orientation of overlapping seeds (10%) should be considered as an estimate at best. The image processing procedure can also be used for seed or catheter detection in CT images, with minor modifications.
Collapse
|
172
|
Lessard E, Hsu I, Pouliot J. Inverse planning dose optimization of interstitial gyn-template high-dose-rate brachytherapy boost. Int J Radiat Oncol Biol Phys 2001. [DOI: 10.1016/s0360-3016(01)02429-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
173
|
Tubic D, Zaccarin A, Beaulieu L, Pouliot J. Automated seed detection and three-dimensional reconstruction. II. Reconstruction of permanent prostate implants using simulated annealing. Med Phys 2001; 28:2272-9. [PMID: 11764032 DOI: 10.1118/1.1414309] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
We present an algorithm, based on simulated annealing, for automatic seed matching and three-dimensional spatial coordinate reconstruction using either three radiographic films or three fluoroscopic images taken from different perspectives. The matching problem is defined in the framework of combinatorial optimization, which allows robust reconstruction in presence of calibration imprecision, patient movements, and isometric distortions. Furthermore, by using a global criterion to select the correct matching, we evade common problems of the three-film method and its variants in presence of noise. The algorithm has been tested on 112 clinical cases and 100 simulated implants and used clinically on more than 100 cases. Simulated implants were reconstructed with an average error of 0.21 mm. For clinical cases, comparison of the precision is performed between results obtained with this new method and results obtained using the three-film technique. Compared to the latter technique, the reconstruction precision was improved in 62% of the clinical cases.
Collapse
|
174
|
Pouliot J, Aubin M, Faddegon B. Electron beam and e-multileaf collimator verification with an A-Si flat panel EPID. Int J Radiat Oncol Biol Phys 2001. [DOI: 10.1016/s0360-3016(01)02141-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
175
|
Lessard E, Pouliot J. Inverse planning anatomy-based dose optimization for HDR-brachytherapy of the prostate using fast simulated annealing algorithm and dedicated objective function. Med Phys 2001; 28:773-9. [PMID: 11393472 DOI: 10.1118/1.1368127] [Citation(s) in RCA: 183] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
An anatomy-based dose optimization algorithm is developed to automatically and rapidly produce a highly conformal dose coverage of the target volume while minimizing urethra, bladder, and rectal doses in the delivery of an high dose-rate (HDR) brachytherapy boost for the treatment of prostate cancer. The dwell times are optimized using an inverse planning simulated annealing algorithm (IPSA) governed entirely from the anatomy extracted from a CT and by a dedicated objective function (cost function) reflecting clinical prescription and constraints. With this inverse planning approach, the focus is on the physician's prescription and constraint instead of on the technical limitations. Consequently, the physician's control on the treatment is improved. The capacity of this algorithm to represent the physician's prescription is presented for a clinical prostate case. The computation time (CPU) for IPSA optimization is less than 1 min (41 s for 142915 iterations) for a typical clinical case, allowing fast and practical dose optimization. The achievement of highly conformal dose coverage to the target volume opens the possibility to deliver a higher dose to the prostate without inducing overdosage of urethra and normal tissues surrounding the prostate. Moreover, using the same concept, it will be possible to deliver a boost dose to a delimited tumor volume within the prostate. Finally, this method can be easily extended to other anatomical sites.
Collapse
|
176
|
Chrétien M, Côté C, Blais R, Brouard L, Roy-Lacroix L, Larochelle M, Roy R, Pouliot J. A variable speed translating couch technique for total body irradiation. Med Phys 2000; 27:1127-30. [PMID: 10841419 DOI: 10.1118/1.598978] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
We have developed a variable speed translating patient couch system for the delivery of total body irradiation (TBI). For a whole body Rando-type phantom, dose variation at mid-plane relative to the prescription point (navel) can be as high as 15% (neck or legs) with a constant velocity. By taking into account variations in body thickness, the intensity modulation radiation therapy, resulting from variable velocities, effectively delivers a uniform dose distribution at mid plane. The couch control user interface, technical aspects and dose planning optimization procedure for determining velocity distribution are described.
Collapse
|
177
|
Taschereau R, Pouliot J, Roy J, Tremblay D. Seed misplacement and stabilizing needles in transperineal permanent prostate implants. Radiother Oncol 2000; 55:59-63. [PMID: 10788689 DOI: 10.1016/s0167-8140(00)00162-6] [Citation(s) in RCA: 71] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND AND PURPOSE Seed misplacement occurring in transperineal permanent implants contributes to the degradation in dose coverage. It has been suggested that needles could be used to immobilize the prostate and help reduce misplacement. This study investigates the effects of parallel stabilizing needles on seed misplacement. MATERIALS AND METHODS A group of ten patients implanted with stabilizing needles was compared with a group of 20 patients implanted without stabilization. Measurements were performed on the displacement of individual seeds and needles. The needle measurements are: insertion angle, the ratio of post-implant over pre-implant lengths and the clustering tendency, a measure of relative misplacement among the seeds of the same needle. RESULTS No difference was observed in seed misplacement. No difference was observed in needle insertion angle, a measure which was expected to improve with the use of stabilizing needles. CONCLUSION None of the expected effects from the use of parallel stabilizing needles have been observed. This method of prostate contention appears to be without benefits. Seed misplacement is most pronounced along the insertion axis and is caused by friction between prostatic tissues and implantation needles. Reducing friction could be a promising alternative to prostate contention in trying to reduce misplacement.
Collapse
|
178
|
Beaulieu L, Tubic D, Pouliot J, Vigneault E, Taschereau R. Post-implant dosimetry using fusion of ultrasound images with 3D seed coordinates from fluoroscopic images in transperineal interstitial permanent prostate brachytherapy. Int J Radiat Oncol Biol Phys 2000. [DOI: 10.1016/s0360-3016(00)80526-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
179
|
Chretien M, Cote C, Larochelle M, Varfalvy N, Pouliot J. IMRT for TBI treatment using a variable speed translating couch technique. Int J Radiat Oncol Biol Phys 2000. [DOI: 10.1016/s0360-3016(00)80484-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
180
|
Lavertu S, Girouard LM, Pouliot J. Observation study of electronic portal images for off-line verification. Radiother Oncol 2000; 54:47-55. [PMID: 10719699 DOI: 10.1016/s0167-8140(99)00171-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
PURPOSE The goals of this study were to evaluate the use of electronic portal imaging device (EPID) paper images as off-line verification tools and to assess the feasibility of replacing portal films by EPID printed images. MATERIALS AND METHODS Electronic portal images were acquired using a video-based imaging system. After contrast enhancement, these images were printed and compared to portal films when prescribed, and judged about their usefulness for off-line verification. A total of 2025 images were acquired from 322 fields on 137 patients. The images were shown to eight radiation oncologists and two senior residents in radiation oncology, each one of them judging fields relevant to his (her) daily practice. The questions asked were related to the choice of important anatomical structures and the visibility of such structures, the usefulness of the printed images, the comparison with portal films and the possible replacement of such films by paper images. RESULTS Answers to the different questions were treated as quantitative scores. For the visibility question, means and standard deviations were calculated for each individual structure, then a global score was obtained for a given treatment site. Means and standard deviations were also computed for the comparison question. Proportions and confidence intervals were used for the other questions. The results show that EPID paper images are useful for some treatment sites such as breast, thorax, prostate, abdomen, pelvis (other than rectum) and axilla. The image quality remains insufficient for some other sites such as head and neck and spine. CONCLUSION Although global anatomical landmarks scores are good, the usefulness score is not always as high because some essential anatomical structures scores must be taken into account. There is also a strong habit factor related to acceptance of EPID printed images as verification tools. As long as they see more and more images, radiation oncologists can more easily visualize anatomical structures and are less stringent when evaluating the efficiency of EPID paper images as off-line verification tools.
Collapse
|
181
|
Létourneau D, Pouliot J, Roy R. Miniature scintillating detector for small field radiation therapy. Med Phys 1999; 26:2555-61. [PMID: 10619239 DOI: 10.1118/1.598793] [Citation(s) in RCA: 85] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
In planning stereotactic radiosurgery treatments, depth dose curves, profiles, and dose rate of treatment beams are difficult to obtain with conventional detectors because of loss of lateral electronic equilibrium and volume averaging. A scintillating detector with high spatial resolution and good reliability has been developed to overcome this problem. The miniature dosimeter consists of two identical radiation-resistant 10 m long silica optical fibers, each connected to an independent silicon photodiode. A small cylindrical polystyrene scintillator (3.9 mm3) is optically glued to the detection fiber. The light seen by the photodiode connected to this fiber arises from fluorescence of the scintillator and from the Cerenkov effect produced in silica. The reference signal produced by the fiber without scintillator is used to subtract the Cerenkov light contribution from the raw detector response. The sensitive volume of the scintillating detector is nearly water-equivalent and thus minimizes dose distribution perturbation in water. The miniature dosimeter has a spatial resolution comparable to the film-densitometer system. Profiles of 1 cm diam, 6 MV photon beam measured with both systems show very similar shapes. Furthermore, the use of photodiodes instead of photomultiplier tubes gives a better stability response and offers the possibility to perform absolute dosimetry.
Collapse
|
182
|
Taschereau R, Roy J, Pouliot J. Monte Carlo simulations of prostate implants to improve dosimetry and compare planning methods. Med Phys 1999; 26:1952-9. [PMID: 10505885 DOI: 10.1118/1.598700] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
The objective of this study is to use Monte Carlo simulations to assess the sensitivity of implant planning methods to seed misplacement. A model of seed misplacement is first developed. It is based upon data gathered after a study on source migration performed on 30 patients treated with I-125 transperineal implants. It consists of applying elementary transformations to every needle in a loading plan to produce a distorted implant mimicking the effect of migration. After being validated, the model has been used to tune the inverse planning system in use at our institution. The new planning system is now used clinically and actual results are compared with those predicted by simulations. Simulations were also used to compare our planning method with others. The new planning system increased the average postimplant dose-volume histogram DVH(160) from 82% to 93%, which is the value predicted by the simulations. This improvement is due to an increased dose margin providing coverage even in the presence of migration. At the same time, the dose to the urethra remained at 267 Gy because of a special protection feature included in the planning system. Some other implant planning methods are not as robust [average DVH(160) ranging from 76% to 85%] and deliver a higher dose to the urethra (close to 400 Gy). To conclude, a simple model of source migration can provide realistic feedback about sensitivity to migration of planning methods. It allowed a significant clinical improvement at our institution. The improved inverse planning system provided better coverage with fewer seeds (but equal total activity) than a manual method. Hence, a properly tuned inverse planning system has the potential to deliver the less sensitive plans. The model also helped demonstrate that planning methods are not equally robust to migration and that they should not be evaluated solely by the plans they produce, but also by their clinical (or simulated) results.
Collapse
|
183
|
Tschereau R, Roy J, Pouliot J. 2283 A comparison of planning methods in permanent prostate implants. Int J Radiat Oncol Biol Phys 1999. [DOI: 10.1016/s0360-3016(99)90551-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
184
|
Girouard LM, Pouliot J, Maldague X, Zaccarin A. Automatic setup deviation measurements with electronic portal images for pelvic fields. Med Phys 1998; 25:1180-5. [PMID: 9682203 DOI: 10.1118/1.598296] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
The purpose of this work was to develop a fully automatic tool for the detection of setup deviation for small pelvic field using, in external beam radiotherapy, an electronic portal imaging device (EPID). The algorithm processes electronic portal images of prostate cancer patients. No fiducial points or user interventions are needed. Deviation measurements are based on bone edge detection performed with Laplacian of a Gaussian (LoG) operator. Two bone edge images are then correlated, one of which is a reference image taken as the first fraction image for the purpose of this study. The electronic portal images (EPI) also show band artefacts which are removed using the morphological top-hat transform. The algorithm was first validated with 59 phantom images acquired in clinical treatment conditions with known displacements. The algorithm was then validated with 79 clinical images where bone contours were delineated manually. For the phantom images, the setup deviations were measured with a absolute mean error of 0.59 mm and 0.47 mm with a standard deviation of 0.64 mm and 0.42 mm, horizontally and vertically, respectively. A second validation was performed using clinical prostate cancer images. The measured patient displacements have an absolute mean error of 0.48 mm and 1.41 mm with a standard deviation of 0.58 mm and 1.30 mm in the X and Y directions, respectively. The algorithm execution time on a SUN workstation is 5 s. This algorithm shows good potential as a setup deviation measurement tool in clinical practice. The possibility of using this algorithm combined with decision rules based on statistical observations is very promising.
Collapse
|
185
|
Lachance B, Tremblay D, Pouliot J. A new penumbra generator for electron fields matching. Med Phys 1997; 24:485-95. [PMID: 9127298 DOI: 10.1118/1.597932] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
Abstract
Abutment of two or more electron fields to irradiate extended areas may lead to significant dose inhomogeneities in the junction region. This paper describes the geometric and dosimetric characteristics of a device developed to modify the penumbra of an electron beam and thereby improve the dose uniformity in the overlap region when fields are abutted. The device is a Lipowitz metal block placed on top of the electron applicator's insertion plate and positioned to stop part of the electron beam on the side of field abutment. The air-scattered electrons beyond the block increase the penumbra width from about 1.4 to 2.7-3.4 cm with an SSD of 100 cm. The modified penumbra is broad and almost linear at all depths for the 9 and 12 MeV electron beams used in this study. Film dosimetry was used to obtain beam profiles and isodose distributions of single modified beams and matched fields of 9 and 12 MeV as well as matched fields of both energies. Computer simulation was used to optimize the skin gap to be used and to quantify the dose uniformity as a function of the field separation for both modified and nonmodified beams. Results are presented for various field configurations. Without the penumbra generator, lateral setup errors of 2-3 mm may introduce dose variations of 20% or more in the junction region. Similar setup errors cause less than 5% dose variations when the penumbra generator is used to match the fields. The potential of the technique for the irradiation of curved surfaces is presented. A possible method for implementing the modified penumbra into a conventional treatment planning system is evaluated.
Collapse
|
186
|
Vigneault E, Pouliot J, Laverdière J, Roy J, Dorion M. Electronic portal imaging device detection of radioopaque markers for the evaluation of prostate position during megavoltage irradiation: a clinical study. Int J Radiat Oncol Biol Phys 1997; 37:205-12. [PMID: 9054897 DOI: 10.1016/s0360-3016(96)00341-0] [Citation(s) in RCA: 213] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
PURPOSE This study was designed to assess daily prostatic apex motion relative to pelvic bone structures during megavoltage irradiation. METHODS AND MATERIALS Radioopaque markers were implanted under ultrasound guidance near the prostatic apex of 11 patients with localized prostatic carcinoma. Patients were subsequently treated with a four field-box technique at a beam energy of 23 MV. During treatment, on-line images were obtained with an electronic portal imaging device (EPID). The marker was easily identified, even on unprocessed images, and the distance between the marker and a bony landmark was measured. Timelapse movies were also reviewed. After the completion of treatment, a transrectal ultrasound examination was performed in 8 of 11 patients, to verify the position of the marker. RESULTS We acquired over 900 digital portal images and analyzed posterioanterior and right lateral views. The quality of portal images obtained with megavoltage irradiation was good. It was possible to evaluate pelvic bone structures even without image histogram equalization. Moreover, the radioopaque marker was easily visible on every online portal image. The review of timelapse movies showed important interfraction motion of the marker while bone structures remained stable. We measured the position of the marker for each fraction. Marker displacements up to 1.6 cm were measured between 2 consecutive days of treatment. Important marker motions were predominantly in the posteroanterior and cephalocaudal directions. In eight patients, we verified the position of the marker relative to the prostatic apex with ultrasound at the end of the treatments. The marker remained in the trapezoid zone. Intratreatment images reviewed in two cases showed no-change in marker position. Our results, obtained during the treatment courses, indicate similar or larger prostate motions than previously observed in studies that used intertreatment x-ray films and CT images. Marker implantation under transrectal ultrasound was well tolerated. CONCLUSIONS Radioopaque marker and the use of electronic portal imaging give a direct evaluation of prostatic motion during radiation treatment. As suggested in previous studies the motions observed are predominantly in the posteroanterior and cephalocaudal directions. Therefore, prostate motion during treatment is important and must be considered especially when using conformal therapy.
Collapse
|
187
|
Pouliot J, Tremblay D, Roy J, Filice S. Optimization of permanent 125I prostate implants using fast simulated annealing. Int J Radiat Oncol Biol Phys 1996; 36:711-20. [PMID: 8948357 DOI: 10.1016/s0360-3016(96)00365-3] [Citation(s) in RCA: 82] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
PURPOSE Treatment planning of ultrasound-guided transperineal 125I permanent prostatic implants is a time-consuming task, due to the large number of seeds used and the very large number of possible source arrangements within the target volume. The goal of this work is to develop an algorithm based on fast simulated annealing allowing consistent and automatic dose distribution optimization in permanent 125I prostatic implants. METHODS AND MATERIALS Fast simulated annealing is used to optimize the dose distribution by finding the best seed distribution through the minimization of a cost function. The cost function includes constraints on the dose at the periphery of the planned target volume and on the dose uniformity within this volume. Adjustment between peripheral dose and the dose uniformity can be achieved by varying the weight factor in the cost function. RESULTS Fast simulated annealing algorithm finds very good seed distributions within 20,000 iterations. The computer time needed for the optimization of a typical permanent implant involving 60 seeds and 14 needles is approximately 15 min. An additional 5 min are necessary for isodose distribution computations and miscellaneous outputs. CONCLUSION The use of fast simulated annealing allows for an efficient and rapid optimization of dose distribution. This algorithm is now routinely used at our institution in the clinical planning of 125I permanent transperineal prostate implants for early stage prostatic carcinoma.
Collapse
|
188
|
Pouliot J, Lirette A. Verification and correction of setup deviations in tangential breast irradiation using EPID: gain versus workload. Med Phys 1996; 23:1393-8. [PMID: 8873036 DOI: 10.1118/1.597722] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023] Open
Abstract
PURPOSE When a deviation in the treatment setup is identified, when or how should it be corrected? With the aim of improving the precision and reducing the systematic errors while maintaining the workload to a minimum, a study was performed to define the proper set of actions for the correction of tangential breast setup deviations during the course of the treatment. PATIENTS AND METHODS Clinical data were taken from a prospective study of more than 2200 on-line Electronic Portal Images (EPI) from 20 patients treated with tangential irradiation following a partial mastectomy for an early stage (I and II) breast cancer. The values of the central lung distance were then entered in the verification/correction procedure and modified to correct only the portion of the deviation most likely attributed to systematic errors according to the maximum likelihood. The verification/ correction procedure uses an action level equal to FML x alpha/square root of N, where alpha is proportional to the standard deviation (alpha = n sigma) and N is the number of consecutive fractions delivered after the start of the treatment. FML is the fraction of the deviation due to the systematic errors estimated from the maximum likelihood of the two distributions. In addition to n, one needs to specify Nmax, the maximum number of consecutive measurements without correction, to apply the procedure. The combination of these two parameters C(n,Nmax) will determine the reduction of systematic errors (gain) and the number of measurements and corrections (workload) associated to the procedure. RESULTS The effects of three combinations, C(1,1), C(2,2), and C(3,4) were studied. Also, the analysis of the results after application of the procedure with and without the factor of maximum likelihood made individually for each patient demonstrates the importance of the FML. CONCLUSIONS The verification/correction procedure with the inclusion of the FML can effectively improve the accuracy when applied to clinical data. With the specific workload related to measurements and corrections performed at our institution, we have found that in the case of the tangential breast treatment, the optimum combination uses an action level equal to 2 sigma and a maximum of two consecutive measurements without correction.
Collapse
|
189
|
Larochelle Y, Beaulieu L, Anctil G, Djerroud B, Doré D, Laforest R, Pouliot J, Roy R, Samri M, St-Pierre C, Ball GC, Bowman DR, Galindo-Uribarri A, Hagberg E, Horn D, Guinet D, Lautesse P. Dependence of intermediate mass fragment production on the reaction mechanism in light heavy-ion collisions at intermediate energy. PHYSICAL REVIEW. C, NUCLEAR PHYSICS 1996; 53:823-837. [PMID: 9971002 DOI: 10.1103/physrevc.53.823] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
|
190
|
Lirette A, Pouliot J, Aubin M, Larochelle M. The role of electronic portal imaging in tangential breast irradiation: a prospective study. Radiother Oncol 1995; 37:241-5. [PMID: 8746594 DOI: 10.1016/0167-8140(95)01653-8] [Citation(s) in RCA: 72] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Side effects due to irradiation of normal tissues and local failure can be associated with deviations in the patient positioning in radiation therapy. In particular, tangential breast irradiation may include normal lung tissue or even a small portion of the heart in the field. A prospective study was performed to assess the precision and the reproducibility of the tangential breast irradiation technique with the help of on-line electronic portal imaging devices (EPID). The influence of respiration on the treatment set-up was evaluated. Also, a comparison was made with simulation films to study the degree of concordance with the intended treatment. Twenty patients with early breast cancer receiving post-operative radiotherapy were entered in the study. Geometrical parameters were measured from daily on-line portal images taken for approximately 17 fractions of each tangential fields. Multiple images were also acquired (six per field) for six fractions for all patients, yielding a total of 2120 images including the simulator films. Random and systematic errors were obtained. Variations of the parameters between various fractions and within the same fraction were about 3 mm (1 SD) or less. Variation between simulation and treatment set-up was 4.3 mm or less. Large maximum deviations, reaching 22.9 mm, were observed in rare cases. This confirms the need to implement daily verification procedures and to correct deviations in the treatment set-up. The study has shown that EPID can help reaching a high accuracy in patient treatment.
Collapse
|
191
|
Scarpaci JA, Chan Y, DiGregorio D, Harmon BA, Pouliot J, Stokstad RG, Suro J. Central collisions in the 16O+12C reaction at 32.5 MeV/nucleon. PHYSICAL REVIEW. C, NUCLEAR PHYSICS 1995; 52:764-774. [PMID: 9970568 DOI: 10.1103/physrevc.52.764] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
|
192
|
Voigt L, Paice JA, Pouliot J. Standardized pain flowsheet: impact on patient-reported pain experiences after cardiovascular surgery. Am J Crit Care 1995; 4:308-13. [PMID: 7663595] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
BACKGROUND Administration of analgesics per patient request or random pain assessments may provide inadequate pain management. OBJECTIVE To examine the impact of nurses' use of a standardized pain flowsheet to document pain assessment and pharmacologic management on patient-reported pain intensity. METHODS A pre-post intervention design was used to compare 61 patients. In the preimplementation group, traditional charting of pain presence or absence was documented in the narrative notes and pharmacologic management was recorded on the medication profile. In the postimplementation group, the intensity of pain and pharmacologic management were documented on a pain flowsheet. Within 24 hours after transfer to the step-down unit, patients were interviewed regarding pain intensity experienced in the surgical heart unit and at the time of questioning. The distribution of these pain intensity scores was compared. RESULTS The postimplementation group reported significantly lower pain intensity ratings for the average amount of pain experienced while in the surgical heart unit, the least amount of pain experienced while in the surgical heart unit, and the pain experienced at the moment of questioning. CONCLUSIONS Use of a standardized pain flowsheet to assess pain intensity and document pharmacologic intervention may improve pain management in postsurgical cardiovascular patients.
Collapse
|
193
|
Voigt L, Paice JA, Pouliot J. Standardized pain flowsheet: impact on patient-reported pain experiences after cardiovascular surgery. Am J Crit Care 1995. [DOI: 10.4037/ajcc1995.4.4.308] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Abstract
BACKGROUND: Administration of analgesics per patient request or random pain assessments may provide inadequate pain management. OBJECTIVE: To examine the impact of nurses' use of a standardized pain flowsheet to document pain assessment and pharmacologic management on patient-reported pain intensity. METHODS: A pre-post intervention design was used to compare 61 patients. In the preimplementation group, traditional charting of pain presence or absence was documented in the narrative notes and pharmacologic management was recorded on the medication profile. In the postimplementation group, the intensity of pain and pharmacologic management were documented on a pain flowsheet. Within 24 hours after transfer to the step-down unit, patients were interviewed regarding pain intensity experienced in the surgical heart unit and at the time of questioning. The distribution of these pain intensity scores was compared. RESULTS: The postimplementation group reported significantly lower pain intensity ratings for the average amount of pain experienced while in the surgical heart unit, the least amount of pain experienced while in the surgical heart unit, and the pain experienced at the moment of questioning. CONCLUSIONS: Use of a standardized pain flowsheet to assess pain intensity and document pharmacologic intervention may improve pain management in postsurgical cardiovascular patients.
Collapse
|
194
|
Beaulieu L, Samri M, Djerroud B, Auger G, Ball GC, Doré D, Galindo-Uribarri A, Gendron P, Hagberg E, Horn D, Jalbert E, Laforest R, Larochelle Y, Laville JL, Lopez O, Plagnol E, Pouliot J, Regimbart R, Roy R, Steckmeyer JC, St-Pierre C, Walker RB. Excitation energies in statistical emission of light charged particles in heavy-ion reactions. PHYSICAL REVIEW. C, NUCLEAR PHYSICS 1995; 51:3492-3495. [PMID: 9970457 DOI: 10.1103/physrevc.51.3492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
|
195
|
Vigneault E, Pouliot J, Laverdiere J, Roy J. 4 EPID detection of radio-opaque markers for the evaluation of prostate position during megavoltage irradiation: A clinical study. Int J Radiat Oncol Biol Phys 1995. [DOI: 10.1016/0360-3016(95)97669-r] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
196
|
Pouliot J, Beaulieu L, Djerroud B, Dore D, Laforest R, Roy R, St-Pierre C, Lopez JA. Erratum: Evidence for the statistical and sequential nature of 16O breakup into four alphas. PHYSICAL REVIEW. C, NUCLEAR PHYSICS 1994; 49:3360. [PMID: 9969629 DOI: 10.1103/physrevc.49.3360.2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
|
197
|
Pouliot J, Beaulieu L, Djerroud B, Doré D, Laforest R, Roy R, St-Pierre C, Lopez JA. Evidence for the statistical and sequential nature of 16O breakup into four alphas. PHYSICAL REVIEW. C, NUCLEAR PHYSICS 1993; 48:2514-2516. [PMID: 9969109 DOI: 10.1103/physrevc.48.2514] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
|
198
|
Sangster TC, Britt HC, Fields DJ, Hansen LF, Lanier RG, Namboodiri MN, Remington BA, Webb ML, Begemann-Blaich M, Blaich T, Fowler MM, Wilhelmy JB, Chan YD, Dacal A, Harmon A, Pouliot J, Stokstad RG, Kaufman S, Videbaek F, Fraenkel Z, Peilert G, Stöcker H, Greiner W, Botvina A, Mishustin IN. Intermediate mass fragment emission in Fe+Au collisions. PHYSICAL REVIEW. C, NUCLEAR PHYSICS 1992; 46:1404-1415. [PMID: 9968248 DOI: 10.1103/physrevc.46.1404] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
|
199
|
Comtois R, Pouliot J, Vinet B, Gervais A, Lemieux C. Higher pentamidine levels in AIDS patients with hypoglycemia and azotemia during treatment of Pneumocystis carinii pneumonia. THE AMERICAN REVIEW OF RESPIRATORY DISEASE 1992; 146:740-4. [PMID: 1519856 DOI: 10.1164/ajrccm/146.3.740] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Trimethoprim-sulfamethoxazole (TMP-SMZ) and pentamidine are both licensed for the treatment of Pneumocystis carinii pneumonia (PCP). However, their use is associated with various adverse side effects. In this prospective study, 26 AIDS patients with 32 episodes of PCP were treated with pentamidine (4 mg/kg/d). Each patient was treated for 12 to 21 days, depending on the rapidity of onset of the clinical response. During the 32 PCP episodes, hypoglycemia occurred in 16 instances, azotemia in 12, liver toxicity in 10, and leukopenia in 8. The occurrence of thrombopenia, leukopenia, and liver toxicity was not related to age, pentamidine levels, or other complications. However, patients who had hypoglycemia during pentamidine treatment had higher serum pentamidine levels than patients who did not have hypoglycemia (107 +/- 40 versus 70 +/- 26 ng/ml, p less than 0.004). In addition, we observed that patients with azotemia showed higher pentamidine levels during treatment (120 +/- 35 versus 64 +/- 22 ng/ml, p less than 0.001). In fact, 100% (11/11) of patients with serum pentamidine concentration greater than 100 ng/ml had fasting hypoglycemia and/or azotemia, while 33% (7/21) of those with pentamidine levels less than 100 ng/ml had these side effects (p less than 0.001). The relative risk of these complications with pentamidine levels greater than 100 ng/ml was 3 (95% confidence interval, 1.6 to 5.5). Fine-tuning the dose of pentamidine may eventually prove useful to avoid toxicity and optimize therapy.
Collapse
|
200
|
Comtois R, Pouliot J, Gervais A, Vinet B, Lemieux C. High pentamidine levels associated with hypoglycemia and azotemia in a patient with Pneumocystis carinii pneumonia. Diagn Microbiol Infect Dis 1992; 15:523-6. [PMID: 1424505 DOI: 10.1016/0732-8893(92)90102-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
We report on a patient who presented with a Pneumocystis carinii pneumonia. Intravenous pentamidine (4 mg/kg/day) was given for 14 days without the occurrence of adverse effects. During this treatment, the mean (+/- SD) serum pentamidine trough concentration was 94 +/- 16 ng/ml. Three days later, the patient was admitted because of fever, and pentamidine (4 mg/kg/day) was again started. Fasting hypoglycemia and azotemia then occurred; the mean serum trough pentamidine level was 190 +/- 10 ng/ml during this week of treatment. We conclude that the occurrence of hypoglycemia and azotemia during pentamidine therapy may not be idiosyncrasic, but seemed associated in our patient with high levels of serum pentamidine.
Collapse
|