76
|
Niclauss L, Letovanec I, Chassot PG, Gersbach PA, von Segesser LK. Acute aortic valve insufficiency and cardiogenic shock due to an isolated giant cell inflammation of the aortic valve leaflets: case report and review of the literature. THE JOURNAL OF HEART VALVE DISEASE 2008; 17:343-347. [PMID: 18592933] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Giant cell arteritis (GCA) is a well-known entity, creating aortic valve regurgitation secondary to dilatation of the aortic wall. No direct involvement of the aortic valve leaflets has yet been documented. A 75-year-old woman with a history of polymyalgia rheumatica and Horton disease was admitted to the authors' institution with acute cardiac failure, severe left ventricular systolic dysfunction and grade III aortic valve insufficiency. The aortic valve was excised and replaced in the usual manner with a pericardial tissue heart valve. Histopathological examination revealed a non-bacterial granulomatous inflammation with giant cells, strictly limited to the valve leaflets. The present case appeared to be the first with isolated involvement of the valve leaflets by GCA, creating acute aortic valve insufficiency.
Collapse
|
77
|
Jegger D, Revelly JP, Horisberger J, von Segesser LK, Ruchat P. Establishing an association between a peri-operative perfusion score system (PerfSCORE) and post-operative patient morbidity/mortality during CPB cardiac surgery. Perfusion 2008; 22:311-6. [PMID: 18416215 DOI: 10.1177/0267659107084524] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND To date, there is no quality assurance program that correlates patient outcome to perfusion service provided during cardiopulmonary bypass (CPB). A score was devised, incorporating objective parameters that would reflect the likelihood to influence patient outcome. The purpose was to create a new method for evaluating the quality of care the perfusionist provides during CPB procedures and to deduce whether it predicts patient morbidity and mortality. METHODS We analysed 295 consecutive elective patients. We chose 10 parameters: fluid balance, blood transfused, Hct, ACT, PaO2, PaCO2, pH, BE, potassium and CPB time. Distribution analysis was performed using the Shapiro-Wilcoxon test. This made up the PerfSCORE and we tried to find a correlation to mortality rate, patient stay in the ICU and length of mechanical ventilation. Univariate analysis (UA) using linear regression was established for each parameter. Statistical significance was established when p < 0.05. Multivariate analysis (MA) was performed with the same parameters. RESULTS The mean age was 63.8 +/- 12.6 years with 70% males. There were 180 CABG, 88 valves, and 27 combined CABG/valve procedures. The PerfSCORE of 6.6 +/- 2.4 (0-20), mortality of 2.7% (8/295), CPB time 100 +/- 41 min (19-313), ICU stay 52 +/- 62 hrs (7-564) and mechanical ventilation of 10.5 +/- 14.8 hrs (0-564) was calculated. CPB time, fluid balance, PaO2, PerfSCORE and blood transfused were significantly correlated to mortality (UA, p < 0.05). Also, CPB time, blood transfused and PaO2 were parameters predicting mortality (MA, p < 0.01). Only pH was significantly correlated for predicting ICU stay (UA). Ultrafiltration (UF) and CPB time were significantly correlated (UA, p < 0.01) while UF (p < 0.05) was the only parameter predicting mechanical ventilation duration (MA). CONCLUSIONS CPB time, blood transfused and PaO2 are independent risk factors of mortality. Fluid balance, blood transfusion, PaO2, PerfSCORE and CPB time are independent parameters for predicting morbidity. PerfSCORE is a quality of perfusion measure that objectively quantifies perfusion performance.
Collapse
|
78
|
von Segesser LK. Imagination turns real, or vice versa? Interact Cardiovasc Thorac Surg 2008; 7:363-4. [PMID: 18367550 DOI: 10.1510/icvts.2008.179549] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
|
79
|
von Segesser LK. Intracardiac welding--a hot technology? Swiss Med Wkly 2008; 138:91-2. [PMID: 18293117 DOI: 2008/07/smw-12245] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
|
80
|
von Segesser LK. Intracardiac welding--a hot technology? Swiss Med Wkly 2008; 138:91-2. [PMID: 18293117 DOI: 10.4414/smw.2008.12245] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
81
|
Tozzi P, Hayoz D, Thévenaz P, Roulet JY, Salchli F, von Segesser LK. Atria assist device to restore transport function of fibrillating atrium☆. Eur J Cardiothorac Surg 2008; 33:263-7. [DOI: 10.1016/j.ejcts.2007.09.042] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/06/2007] [Revised: 09/16/2007] [Accepted: 09/18/2007] [Indexed: 10/22/2022] Open
|
82
|
von Segesser LK, Tozzi P, Augstburger M, Corno A. Working heart off-pump cardiac repair (OPCARE)--the next step in robotic surgery? Interact Cardiovasc Thorac Surg 2007; 2:120-4. [PMID: 17670006 DOI: 10.1016/s1569-9293(02)00117-2] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
The objective of the present study was to assess the feasibility of working heart off-pump cardiac repair (OPCARE), for example, for simple congenital defects or valves, with the help of a commercially available surgical robot in order to identify problem areas and to explore potential solutions. OPCARE was studied in four bovine experiments using the Zeus (Computermotion, Santa Barbara, CA, USA) surgical robot providing 3D viewing of the extra cardiac instruments in combination with two intra-cardiac ultrasound visualisation systems (Clearview Ultra, Boston Scientific, La Garenne, France) and Accunav (Accuson, Mountain View, CA, USA) allowing for two different viewing planes of the heart and identification of both, intra-cardiac structures and intra-cardiac robotic instruments. For the given experimental set-up, introduction of robotic instruments into the right atrium (typical for instrumentation during OPCARE), grabbing of the second instrument (typical for removal of intra-cardiac foreign bodies), and grabbing of relatively still atrial structures, which can be visualised by intra-cardiac ultrasound (typical for resection of specific cardiac tissue, clipping of a specific cardiac structure, steered access to other cardiac cavities) have been realised with relative ease. In contrast, grabbing of moving cardiac structures like a-v valve leaflets (typical for valve testing and absolutely necessary for valve repair) required, in general, numerous attempts, but was finally successful in the majority of test animals. Finally, introduction of self-attaching suture material (U-clips, Coalescent Surgical, Sunnyvale, CA, USA) typical for edge-to-edge valve repair could not be performed in reproducible fashion with the equipment used. We conclude that OPCARE is feasible for simple intra-cardiac lesions using current robotic instrumentation and state of the art intra-cardiac ultrasound. However, more complex procedures require further development of both robotic instrumentation and intra-cardiac visualisation.
Collapse
|
83
|
Mueller XM, Mallabiabrena I, Mucciolo G, von Segesser LK. Optimized venous return with a self-expanding cannula: from computational fluid dynamics to clinical application. Interact Cardiovasc Thorac Surg 2007; 1:23-7. [PMID: 17669950 DOI: 10.1016/s1569-9293(02)00006-3] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
The Smart canula concept allows for collapsed cannula insertion, and self-expansion within a vein of the body. (A) Computational fluid dynamics, and (B) bovine experiments (76+/-3.8 kg) were performed for comparative analyses, prior to (C) the first clinical application. For an 18F access, a given flow of 4 l/min (A) resulted in a pressure drop of 49 mmHg for smart cannula versus 140 mmHg for control. The corresponding Reynolds numbers are 680 versus 1170, respectively. (B) For an access of 28F, the maximal flow for smart cannula was 5.8+/-0.5 l/min versus 4.0+/-0.1 l/min for standard (P<0.0001), for 24F 5.5+/-0.6 l/min versus 3.2+/-0.4 l/min (P<0.0001), and for 20F 4.1+/-0.3 l/min versus 1.6+/-0.3 l/min (P<0.0001). The flow obtained with the smart cannula was 270+/-45% (20F), 172+/-26% (24F), and 134+/-13% (28F) of standard (one-way ANOVA, P=0.014). (C) First clinical application (1.42 m2) with a smart cannula showed 3.55 l/min (100% predicted) without additional fluids. All three assessment steps confirm the superior performance of the smart cannula design.
Collapse
|
84
|
von Segesser LK, Tozzi P, Ferrari ER, Huber C, Delay D, Jegger D, Horisberger J. Small access (30F) clinical central venous smart cannulation: is it adequate? Interact Cardiovasc Thorac Surg 2007; 5:540-3. [PMID: 17670641 DOI: 10.1510/icvts.2006.134676] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
OBJECTIVES To assess the performance of 45F vs. 36F smartcanula in CPB with gravity drainage alone. METHODS Twenty patients were randomly assigned to two groups receiving for venous drainage a smartcanula which is collapsed over a mandrel for trans-atrial insertion into the inferior vena cava and expanded in situ to either 45F or 36F. RESULTS Valve replacement/repair was realized in 7/10 and/or CABG in 6/10 for 36F (69+/-13 years) vs. 5/10 and 5/10, respectively, for 45F (63+/-11 years: NS). Body weight and surface area (BSA) were 83+/-9 kg (1.9+/-0.2 m2, max 2.2 m2) for 36F vs. 79+/-6 kg: NS (1.9+/-0.1 m2 (NS), max 2.1 m2) for 45F. Insertion and access orifice diameter (area) was 6 mm and 10 mm (78.5 mm2) for the 36F vs. 6 mm and 13 mm (132 mm2) for the 45F (+69%). Calculated target pump flow (2.4 l/min/m2) was 4.7+/-0.4 l/min for 36F vs. 4.5+/-0.3 l/min for 45F. Achieved pump flow accounted for 5.0+/-0.3 l/min for 36F (8% above target) vs. 4.8+/-0.3 l/min for 45F (8% above target): NS. The water balance during the pump run (clear volume added minus hemofilter and urine output) was 2.2+/-0.3 l for 36F vs. 2.0 l for 45F: NS. CONCLUSION Due to its 'open' wall (the vena cava provides the seal), its reduced wall thickness (range: 0.0-0.4 mm), and its self-expanding design, the 36F smartcanula requiring a 30F access orifice has sufficient drainage capacity by gravity alone for full CPB in adults with a BSA up to 2.2 mm2.
Collapse
|
85
|
Huber CH, Marty B, von Segesser LK. Acceptance and introduction of disruptive technologies - simple steps to build a fully functional pulmonary valved stent. Interact Cardiovasc Thorac Surg 2007; 6:430-2. [PMID: 17669890 DOI: 10.1510/icvts.2007.153494] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Valved stents are new land for cardiac surgeons even though they are being used more frequently by interventional disciplines. This paper presents simple steps to build a patient-specific pulmonary valved stent and its delivery device. The design concept was tested by random participants at a med-tech meeting. The valved stent is constructed by linking an endoprosthetic graft with a valved-jugular-vein. The delivery device is made from a modified 5-ml syringe. Of 72 participants, 66 (92%) built and 60 participants implanted the device successfully into the targeted pulmonary position via a trans-infundibular access.
Collapse
|
86
|
von Segesser LK. From the magic mountain to rocket science in thoracic and cardiovascular surgery. Interact Cardiovasc Thorac Surg 2007; 2:217-8. [PMID: 17670032 DOI: 10.1016/s1569-9293(03)00140-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
87
|
von Segesser LK. The fourth dimension for Interactive Cardiovascular and Thoracic Surgery--on-line video brings life to publications! Interact Cardiovasc Thorac Surg 2007; 2:1-2. [PMID: 17669973 DOI: 10.1016/s1569-9293(03)00012-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
|
88
|
Meyer MAR, von Segesser LK, Hurni M, Stumpe F, Eisa K, Ruchat P. Long-term outcome after mitral valve repair: a risk factor analysis. Eur J Cardiothorac Surg 2007; 32:301-7. [PMID: 17561410 DOI: 10.1016/j.ejcts.2007.05.008] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2006] [Revised: 04/26/2007] [Accepted: 05/14/2007] [Indexed: 11/19/2022] Open
Abstract
OBJECTIVE Mitral valve repair is the gold standard to restore mitral valve function and is now known to have good long-term outcome. In order to help perioperative decision making, we analyzed our collective to find independent risk factors affecting their outcome. METHODS We retrospectively studied our first 175 consecutive adult patients (mean age: 64+/-10.4 years; 113 males) who underwent primary mitral valve repair associated with any other cardiac procedures between January 1986 and December 1998. Risk factors influencing reoperations and late survival were plotted in a uni- and multivariate analyses. RESULTS Operative mortality was 3.4% (6 deaths, 0-22nd postoperative day (POD)). Late mortality was 9.1% (16 deaths, 3rd-125th POM). Reoperation was required in five patients. Kaplan-Meier actuarial analysis demonstrated a 96+/-1% 1-year survival, 88+/-3% 5-year survival and a 69+/-8% 10-year survival. Freedom from reoperations was 99% at 1 year after repair, 97+/-2% after 5 years and 88+/-6% after 10 years. Multivariate analysis demonstrated that residual NYHA class III and IV (p=0.001, RR 4.55, 95% CI: 1.85-14.29), poor preoperative ejection fraction (p=0.013, RR 1.09, 95% CI: 1.02-1.18), functional MR (p=0.018, RR 4.17, 95% CI: 1.32-16.67), and ischemic MR (p=0.049, RR 3.13, 95% CI: 1.01-10.0) were all independent predictors of late death. Persistent mitral regurgitation at seventh POD (p=0.005, RR 4.55, 95% CI: 1.56-20.0), age below 60 (p=0.012, RR 8.7, 95% CI: 2.44-37.8), and absence of prosthetic ring (p=0.034, RR 4.76, 95% CI: 1.79-33.3) were all independent risk factors for reoperation. CONCLUSIONS Mitral valve repair provides excellent survival. However, long-term outcome can be negatively influenced by perioperative risk factors. Risk of reoperation is higher in younger patients with a residual mitral regurgitation and without ring annuloplasty.
Collapse
|
89
|
Sekarski N, van Meir H, Rijlaarsdam MEB, Schoof PH, Koolbergen DR, Hruda J, von Segesser LK, Meijboom EJ, Hazekamp MG. Right Ventricular Outflow Tract Reconstruction With the Bovine Jugular Vein Graft: 5 Years’ Experience With 133 Patients. Ann Thorac Surg 2007; 84:599-605. [PMID: 17643642 DOI: 10.1016/j.athoracsur.2007.04.026] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/13/2006] [Revised: 04/04/2007] [Accepted: 04/05/2007] [Indexed: 10/23/2022]
Abstract
BACKGROUND We analyzed the results in two centers of using bovine jugular vein graft for right ventricular outflow tract reconstruction. METHODS From April 1999 to July 2005, 133 children with a median age of 30.9 months (range, 4 days to 19 years) underwent graft implantation. Echocardiography was performed during follow-up and retrospectively reviewed. RESULTS Nongraft-related early mortality occurred in 8 patients. Late mortality occurred in 11 patients, 2 late deaths were graft related (endocarditis). Median follow-up was 31.6 months (range, 1 to 73). Twelve patients received a new graft, because of endocarditis (3), distal pulmonary artery branch stenosis (4), graft obstruction caused by fibrosis (4), or thrombosis (1). Echocardiography Doppler studies showed good conduit function, with 92% of the patients having absent, trivial, or only mild valve regurgitation at last follow-up. A moderate degree of conduit stenosis due to external compression was observed in 2 patients. Twenty-five patients with otherwise intact conduits had hemodynamically significant distal stenosis. In most cases, the pulmonary branch stenosis was related to preoperative small pulmonary arteries and young age at operation. At 31.6 months, significant graft dilatation was observed in 4 grafts and was related to pulmonary artery branch obstruction or pulmonary hypertension. Calcification did not occur in 5 years time. Survival was 85.7%, freedom from conduit explantation was 91%, and freedom from intervention for pulmonary artery branch stenosis was 80% after 5 years. CONCLUSIONS The bovine jugular vein graft is a valuable right ventricular outflow tract conduit, but younger age and small pulmonary arteries increase the risk of distal conduit stenosis.
Collapse
|
90
|
Jegger D, da Silva RF, Lartaud I, Gaillard V, Jeanrenaud X, Nasratullah M, von Segesser LK, Atkinson J, Segers P, Tevaearai H, Stergiopulos N. Effects of an aging vascular model on healthy and diseased hearts. Am J Physiol Heart Circ Physiol 2007; 293:H1334-43. [PMID: 17616750 DOI: 10.1152/ajpheart.00341.2007] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The vitamin D(3) and nicotine (VDN) model is a model of isolated systolic hypertension (ISH) due to arterial calcification raising arterial stiffness and vascular impedance similar to an aged and stiffened arterial tree. We therefore analyzed the impact of this aging model on normal and diseased hearts with myocardial infarction (MI). Wistar rats were treated with VDN (n = 9), subjected to MI by coronary ligation (n = 10), or subjected to a combination of both MI and VDN treatment (VDN/MI, n = 14). A sham-treated group served as control (Ctrl, n = 10). Transthoracic echocardiography was performed every 2 wk, whereas invasive indexes were obtained at week 8 before death. Calcium, collagen, and protein contents were measured in the heart and the aorta. Systolic blood pressure, pulse pressure, thoracic aortic calcium, and end-systolic elastance as an index of myocardial contractility were highest in the aging model group compared with MI and Ctrl groups (P(VDN) < 0.05, 2-way ANOVA). Left ventricular wall stress and brain natriuretic peptide (P(VDNxMI) = not significant) were highest, while ejection fraction, stroke volume, and cardiac output were lowest in the combined group versus all other groups (P(VDNxMI) < 0.05). The combination of ISH due to this aging model and MI demonstrates significant alterations in cardiac function. This model mimics several clinical phenomena of cardiovascular aging and may thus serve to further study novel therapies.
Collapse
|
91
|
Caretti A, Morel S, Milano G, Fantacci M, Bianciardi P, Ronchi R, Vassalli G, von Segesser LK, Samaja M. Heart HIF-1alpha and MAP kinases during hypoxia: are they associated in vivo? Exp Biol Med (Maywood) 2007; 232:887-94. [PMID: 17609504] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/16/2023] Open
Abstract
To study the in vivo dynamics of hypoxia-inducible factor 1alpha (HIF-1alpha), master regulator of O(2)-dependent gene expression, and mitogen-activated protein kinases (MAPKs) in the hypoxic myocardium, Sprague-Dawley rats (n = 4 to 6 per group) were exposed to 1-hr hypoxia (10% O(2)), 23-hr hypoxia, and 23-hr hypoxia, followed by reoxygenation. HIF-1alpha increased 15-fold after 1-hr hypoxia, remained constant for 23 hrs, and returned to baseline on reoxygenation. Extracellular signal-regulated kinases (ERK1/2) were unchanged throughout. Phosphorylated p38 increased 4-fold after 1-hr hypoxia and returned to baseline within 23-hr hypoxia. The activity of stress-activated protein kinases/c-Jun NH(2)-terminal kinases (JNKs), measured as phosphorylated c-Jun, increased 3-fold after 1-hr hypoxia and remained sustained afterward. Furthermore, HIF-1alpha was halved in rats that were administered with the p38 inhibitor SB202190 and made hypoxic for 1 hr. In conclusion, although very sensitive to the reoxygenation, HIF-1alpha is overexpressed in vivo in the hypoxic myocardium, and its acute induction by hypoxia is correlated with that of p38.
Collapse
|
92
|
Dudler J, Simeoni E, Fleury S, Li J, Pagnotta M, Pascual M, von Segesser LK, Vassalli G. Gene transfer of interleukin-18-binding protein attenuates cardiac allograft rejection. Transpl Int 2007; 20:460-6. [PMID: 17313449 DOI: 10.1111/j.1432-2277.2007.00457.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
Interleukin (IL) 18 is a potent pro-inflammatory Th1 cytokine that exerts pleiotropic effector functions in both innate and acquired immune responses. Increased IL-18 production during acute rejection has been reported in experimental heart transplantation models and in kidney transplant recipients. IL-18-binding protein (IL-18BP) binds IL-18 with high affinity and neutralizes its biologic activity. We have analyzed the efficacy of an adenoviral vector expressing an IL-18BP-Ig fusion protein in a rat model of heart transplantation. IL-18BP-Ig gene transfer into Fisher (F344) rat donor hearts resulted in prolonged graft survival in Lewis recipients (15.8 +/- 1.4 days vs. 10.3 +/- 2.5 and 10.1 +/- 2.1 days with control virus and buffer solution alone, respectively; P < 0.001). Immunohistochemical analysis revealed decreased intra-graft infiltrates of monocytes/macrophages, CD4(+), CD8alpha(+) and T-cell receptor alphabeta(+) cells after IL-18BP-Ig versus mock gene transfer (P < 0.05). Real-time reverse transcriptase polymerase chain reaction analysis showed decreased cytokine transcripts for the RANTES chemokine and transforming growth factor-beta after IL-18BP-Ig gene transfer (P < 0.05). IL-18BP-Ig gene transfer attenuates inflammatory cell infiltrates and prolongs cardiac allograft survival in rats. These results suggest a contributory role for IL-18 in acute rejection. Further studies aiming at defining the therapeutic potential of IL-18BP are warranted.
Collapse
|
93
|
Jegger D, Tevaearai HT, Mallabiabarrena I, Horisberger J, Seigneul I, von Segesser LK. Comparing Oxygen Transfer Performance Between Three Membrane Oxygenators: Effect of Temperature Changes During Cardiopulmonary Bypass. Artif Organs 2007; 31:290-300. [PMID: 17437498 DOI: 10.1111/j.1525-1594.2007.00379.x] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Recently, a new oxygenator (Dideco 903 [D903], Dideco, Mirandola, Italy) has been introduced to the perfusion community, and we set about testing its oxygen transfer performance and then comparing it to two other models. This evaluation was based on the comparison between oxygen transfer slope, gas phase arterial oxygen gradients, degree of blood shunting, maximum oxygen transfer, and diffusing capacity calculated for each membrane. Sixty patients were randomized into three groups of oxygenators (Dideco 703 [D703], Dideco; D903; and Quadrox, Jostra Medizintechnik AG, Hirrlingen, Germany) including 40/20 M/F of 68.6 +/- 11.3 years old, with a body weight of 71.5 +/- 12.1 kg, a body surface area (BSA) of 1.84 +/- 0.3 m(2), and a theoretical blood flow rate (index 2.4 times BSA) of 4.4 +/- 0.7 L/min. The maximum oxygen transfer (VO(2)) values were 313 mL O(2)/min (D703), 579 mL O(2)/min (D903), and 400 mL O(2)/min (Quadrox), with the D903 being the most superior (P < 0.05). Oxygen (O(2)) gradients were 320 mm Hg (D703), 235 mm Hg (D903), and 247 mm Hg (Quadrox), meaning D903 and Quadrox are more efficient versus the D703 (P < 0.05). Shunt fraction (Qs/Qt) and diffusing capacity (DmO(2)) were comparable (P = ns). Diffusing capacity values indexed to BSA (DmO(2)/m(2)) were 0.15 mL O(2)/min/mm Hg/m(2) (D703), 0.2 mL O(2)/min/mm Hg/m(2) (D903), and 0.18 mL O(2)/min/mm Hg/m(2) (Quadrox) with D903 outperforming D703 (P < 0.0005). During hypothermia (32.0 +/- 0.3 degrees C), there was a lower absolute and relative VO(2 )for all three oxygenators (P = ns). The O(2) gradients, DmO(2) and DmO(2)/m(2), were significantly lower for all oxygenators (P < 0.01). Also, Qs/Qt significantly rose for all oxygenators (P < 0.01). The oxygen transfer curve is characteristic to each oxygenator type and represents a tool to quantify oxygenator performance. Using this parameter, we demonstrated significant differences among commercially available oxygenators. However, all three oxygenators are considered to meet the oxygen needs of the patients.
Collapse
|
94
|
Milano G, Morel S, Bonny C, Samaja M, von Segesser LK, Nicod P, Vassalli G. A peptide inhibitor of c-Jun NH2-terminal kinase reduces myocardial ischemia-reperfusion injury and infarct size in vivo. Am J Physiol Heart Circ Physiol 2007; 292:H1828-35. [PMID: 17158645 DOI: 10.1152/ajpheart.01117.2006] [Citation(s) in RCA: 86] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The c-Jun NH2-terminal kinase (JNK) pathway of the mitogen-activated protein kinase (MAPK) signaling cascade regulates cell function and survival after stress stimulation. Equally robust studies reported dichotomous results suggesting both protective and detrimental effects of JNK during myocardial ischemia-reperfusion (I/R). The lack of a highly specific JNK inhibitor contributed to this controversy. We recently developed a cell-penetrating, protease-resistant peptide inhibitor of JNK, d-JNKI-1. Here we report on the effects of d-JNKI-1 in myocardial I/R. d-JNKI-1 was tested in isolated-perfused adult rat hearts. Increased activation of JNK, p38-MAPK, and extracellular signal-regulated kinase-1/2 (ERK1/2), as assessed by kinase assays and Western blotting, occurred during I/R. d-JNKI-1 delivered before onset of ischemia prevented the increase in JNK activity while not affecting ERK1/2 and p38-MAPK activation. JNK inhibition reduced ischemic injury, as manifested by increased time to contracture ( P < 0.05) and decreased left ventricular end-diastolic pressure during ischemia ( P < 0.01), and enhanced posthypoxic recovery of systolic and diastolic function ( P < 0.01). d-JNKI-1 reduced mitochondrial cytochrome- c release, caspase-3 activation, and the number of apoptotic cells determined by terminal deoxynucleotidyltransferase-mediated dUTP nick-end labeling ( P < 0.05), indicating suppression of the mitochondrial machinery of apoptosis. d-JNKI-1 delivered at the time of reperfusion did not improve functional recovery but still prevented apoptosis. In vivo, d-JNKI-1 reduced infarct size after coronary artery occlusion and reperfusion by ∼50% ( P < 0.01). In conclusion, d-JNKI-1 is an important compound that can be used in preclinical models to investigate the role of JNK signaling in vivo. Inhibition of JNK during I/R is cardioprotective in anesthetized rats in vivo.
Collapse
|
95
|
Tozzi P, Pawelec-Wojtalic M, Bukowska D, Ferrari E, Siniscalchi G, von Segesser LK. Endoscopic access closure for direct implantation of valved stents. Swiss Med Wkly 2007; 137:182-4. [PMID: 17457701 DOI: 10.4414/smw.2007.11561] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
OBJECTIVES The off-pump trans left ventricular approach provides an alternative option for insertion of stented aortic valves of any size for endovascular replacement. One of the key steps in this procedure is the repair of the ventricle after catheter withdrawal. This study evaluates the reliability of a new device for sutureless and quick repair of the left ventricle access. METHODS The Amplatz-nitinol occluder consists of two square heads that squeeze the ventricle wall between them thus sealing the ventricular defect. In four adult pigs weighing 55 kg, left thoracoscopy was performed to open the pericardium and visualise the cardiac apex. Following a heparin injection (100 U/kg) under ICUS and fluoroscopic control, we inserted a 30 F sheath into the epigastric area through the cardiac apex up into the left ventricle thus simulating the approach for an off-pump aortic valve replacement. The sheath was then removed and the ventricle closed with the occluder. Animals were followed-up for three hours; the haemodynamics and pericardial bleeding were recorded. The animals were then sacrificed and the gross anatomy of the heart was examined. RESULTS The device was successfully deployed in four animals in less than one minute. ACT was above 200 seconds in all cases. All animals survived the procedure with a mean arterial pressure of 50 +/- 15 mm Hg. Bleeding during deployment was 80 +/- 20 ml and over a 3 hour period was 800 +/- 20 ml. Examination of the gross anatomy examination demonstrated the correct positioning of the device. CONCLUSIONS The occluder is easy to use and the procedure is feasible and reproducible. However, the occluder design requires technical improvements in order to reduce bleeding before it can be used clinically.
Collapse
|
96
|
Tozzi P, Pawelec-Wojtalic M, Bukowska D, Ferrari E, Siniscalchi G, von Segesser LK. Endoscopic access closure for direct implantation of valved stents. Swiss Med Wkly 2007; 137:182-4. [PMID: 17457701 DOI: 2007/11/smw-11561] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
OBJECTIVES The off-pump trans left ventricular approach provides an alternative option for insertion of stented aortic valves of any size for endovascular replacement. One of the key steps in this procedure is the repair of the ventricle after catheter withdrawal. This study evaluates the reliability of a new device for sutureless and quick repair of the left ventricle access. METHODS The Amplatz-nitinol occluder consists of two square heads that squeeze the ventricle wall between them thus sealing the ventricular defect. In four adult pigs weighing 55 kg, left thoracoscopy was performed to open the pericardium and visualise the cardiac apex. Following a heparin injection (100 U/kg) under ICUS and fluoroscopic control, we inserted a 30 F sheath into the epigastric area through the cardiac apex up into the left ventricle thus simulating the approach for an off-pump aortic valve replacement. The sheath was then removed and the ventricle closed with the occluder. Animals were followed-up for three hours; the haemodynamics and pericardial bleeding were recorded. The animals were then sacrificed and the gross anatomy of the heart was examined. RESULTS The device was successfully deployed in four animals in less than one minute. ACT was above 200 seconds in all cases. All animals survived the procedure with a mean arterial pressure of 50 +/- 15 mm Hg. Bleeding during deployment was 80 +/- 20 ml and over a 3 hour period was 800 +/- 20 ml. Examination of the gross anatomy examination demonstrated the correct positioning of the device. CONCLUSIONS The occluder is easy to use and the procedure is feasible and reproducible. However, the occluder design requires technical improvements in order to reduce bleeding before it can be used clinically.
Collapse
|
97
|
Jegger D, Horisberger J, Jachertz M, Seigneul I, Tozzi P, Delay D, von Segesser LK. A novel device for reducing hemolysis provoked by cardiotomy suction during open heart cardiopulmonary bypass surgery: a randomized prospective study. Artif Organs 2007; 31:23-30. [PMID: 17209957 DOI: 10.1111/j.1525-1594.2007.00336.x] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
Since the inception of cardiopulmonary bypass (CPB), little progress has been made concerning the design of cardiotomy suction (CS). Because this is a major source of hemolysis, we decided to test a novel device (Smartsuction [SS]) specifically aimed at minimizing hemolysis during CPB in a clinical setting. Block randomization was carried out on a treated group (SS, n=28) and a control group (CTRL, n=26). Biochemical parameters were taken pre-, peri-, and post CPB and were compared between the two groups using the Student's t-test with statistical significance when P<0.05. No significant differences in patient demographics were observed between the two groups. Lactate dehydrogenase (LDH) and plasma free hemoglobin (PFH) pre-CPB were comparable for the CTRL and SS groups, respectively. LDH peri-CPB was 275+/-100 U/L versus 207+/-83 U/L for the CTRL and SS groups, respectively (P<0.05). PFH was 486+/-204 mg/L versus 351+/-176 mg/L for the CTRL and SS groups, respectively (P<0.05). LDH post CPB was 354+/-116 U/L versus 275+/-89 U/L for the CTRL and SS groups, respectively (P<0.05). PFH was 549+/-271 mg/L versus 460+/-254 mg/L for the CTRL and SS groups, respectively (P<0.05). Preoperative hematocrit (Hct) of 43+/-5% (CTRL) versus 37+/-5% (SS), and hemoglobin (Hb) of 141+/-16 g/L (CTRL) versus 122+/-17 g/L (SS) were significantly lower in the SS group. However, when normalized (N), the SS was capable of conserving Hct, Hb, and erythrocyte count perioperatively. Erythrocytes (N) were 59+/-5% (CTRL) versus 67+/-9% (SS); Hct (N) was 59+/-6% (CTRL) versus 68+/-9% (SS), and Hb (N) was 61+/-6% (CTRL) versus 70+/-10% (SS) (all P<0.05). This novel SS device evokes significantly lowered blood PFH and LDH values peri- and post CPB compared with the CTRL blood using a CS system. The SS may be a valuable alternative compared to traditional CS techniques.
Collapse
|
98
|
Dudler J, Li J, Pagnotta M, Pascual M, von Segesser LK, Vassalli G. Gene transfer of programmed death ligand-1.Ig prolongs cardiac allograft survival. Transplantation 2007; 82:1733-7. [PMID: 17198268 DOI: 10.1097/01.tp.0000250757.69384.79] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
BACKGROUND The CD28 homologue programmed death-1 (PD-1) and its ligands, PD-L1 and PD-L2 (which are homologous to B7), constitute an inhibitory pathway of T cell costimulation. The PD-1 pathway is of interest for immune-mediated diseases given that PD-1-deficient mice develop autoimmune diseases. We have evaluated the effect of local overexpression of a PD-L1.Ig fusion protein on cardiac allograft survival. METHODS Adenovirus-mediated PD-L1.Ig gene transfer was performed in F344 rat donor hearts placed in the abdominal position in Lewis recipients. Inflammatory cell infiltrates in the grafts were assessed by immunohistochemistry. RESULTS Allografts transduced with the PD-L1.Ig gene survived for longer periods of time compared with those receiving noncoding adenovirus or virus dilution buffer alone: median survival time (MST), 17 (range: 16-20) days vs. 11 (8-14) and 9 (8-13) days, respectively (P < 0.001). PD-L1.Ig gene transfer combined with a subtherapeutic regimen of cyclosporin A (CsA) was superior to CsA alone: MST, 25 (15-42) vs. 15 (13-19) days (P < 0.05). PD-L1.Ig gene transfer was associated with decreased numbers of CD4 cells and monocytes/macrophages infiltrating the graft (P < 0.05). CONCLUSIONS Localized PD-L1.Ig expression in donor hearts attenuates acute allograft rejection in a rat model. The effect is additive to that of a subtherapeutic regimen of CsA. These results suggest that targeting of PD-1 by gene therapy may inhibit acute cardiac allograft rejection in vivo.
Collapse
|
99
|
von Segesser LK, Jegger D, Mucciolo G, Tozzi P, Mucciolo A, Delay D, Mallabiabarrena I, Horisberger J. The Smartcanula: a new tool for remote access perfusion in limited access cardiac surgery. Heart Surg Forum 2007; 8:E241-5. [PMID: 16112936 DOI: 10.1532/hsf98.20051127] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Devices for venous cannulation have seen significant progress over time: the original, rigid steel cannulas have evolved toward flexible plastic cannulas with wire support that prevents kinking, very thin walled wire wound cannulas allowing for percutaneous application, and all sorts of combinations. In contrast to all these rectilinear venous cannula designs, which present the same cross-sectional area over their entire intravascular path, the smartcanula concept of "collapsed insertion and expansion in situ" is the logical next step for venous access. Automatically adjusting cross-sectional area up to a pre-determined diameter or the vessel lumen provides optimal flow and ease of use for both, insertion and removal. Smartcanula performance was assessed in a small series of patients (76 +/- 17 kg) undergoing redo procedures. The calculated target pump flow (2.4 L/min/m2) was 4.42 +/- 61 L/ min. Mean pump flow achieved during cardiopulmonary bypass was 4.84 +/- 87 L/min or 110% of the target. Reduced atrial chatter, kink resistance in situ, and improved blood drainage despite smaller access orifice size, are the most striking advantages of this new device. The benefits of smart cannulation are obvious in remote cannulation for limited access cardiac surgery, but there are many other cannula applications where space is an issue, and that is where smart cannulation is most effective.
Collapse
|
100
|
Simeoni E, Dudler J, Fleury S, Li J, Pagnotta M, Pascual M, von Segesser LK, Vassalli G. Gene transfer of a soluble IL-1 type 2 receptor-Ig fusion protein improves cardiac allograft survival in rats☆. Eur J Cardiothorac Surg 2007; 31:222-8. [PMID: 17182252 DOI: 10.1016/j.ejcts.2006.10.042] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/27/2006] [Revised: 10/11/2006] [Accepted: 10/23/2006] [Indexed: 10/23/2022] Open
Abstract
OBJECTIVE Interleukin-1 (IL-1) mediates ischemia-reperfusion injury and graft inflammation after heart transplantation. IL-1 affects target cells through two distinct types of transmembrane receptors, type-1 receptor (IL-1R1), which transduces the signal, and the non-signaling type-2 receptor (IL-1R2), which acts as a ligand sink that subtracts IL-1beta from IL-1R1. We analyzed the efficacy of adenovirus (Ad)-mediated gene transfer of a soluble IL-1R2-Ig fusion protein in delaying cardiac allograft rejection and the mechanisms underlying the protective effect. METHODS IL-1 inhibition by IL-1R2-Ig was tested using an in vitro functional assay whereby endothelial cells preincubated with AdIL-1R2-Ig or control virus were stimulated with recombinant IL-1beta or tumor necrosis factor-alpha (TNF-alpha), and urokinase-type plasminogen activator (u-PA) induction was measured by zymography. AdIL-1R2-Ig was delivered to F344 rat donor hearts ex vivo, which were placed in the abdominal position in LEW hosts. Intragraft inflammatory cell infiltrates and proinflammatory cytokine expression were analyzed by immunohistochemistry and real-time reverse transcriptase-polymerase chain reaction (RT-PCR), respectively. RESULTS IL-1R2-Ig specifically inhibited IL-1beta-induced u-PA responses in vitro. IL-1R2-Ig gene transfer reduced intragraft monocytes/macrophages and CD4(+) cell infiltrates (p<0.05), TNF-alpha and transforming growth factor-beta (TGF-beta) expression (p<0.05), and prolonged graft survival (15.6+/-5.7 vs 10.3+/-2.5 days with control vector and 10.1+/-2.1 days with buffer alone; p<0.01). AdIL-1R2-Ig combined with a subtherapeutic regimen of cyclosporin A (CsA) was superior to CsA alone (19.4+/-3.0 vs 15.9+/-1.8 days; p<0.05). CONCLUSIONS Soluble IL-1 type-2 receptor gene transfer attenuates cardiac allograft rejection in a rat model. IL-1 inhibition may be useful as an adjuvant therapy in heart transplantation.
Collapse
|