76
|
Fujita Y, Shibata A, Ogimoto I, Kurozawa Y, Nose T, Yoshimura T, Suzuki H, Iwai N, Sakata R, Ichikawa S, Tamakoshi A. The effect of interaction between hepatitis C virus and cigarette smoking on the risk of hepatocellular carcinoma. Br J Cancer 2006; 94:737-9. [PMID: 16465190 PMCID: PMC2361208 DOI: 10.1038/sj.bjc.6602981] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
We evaluated the interaction between hepatitis C virus (HCV) and cigarette smoking on death from hepatocellular cancer in The Japan Collaborative Cohort Study. The odds ratio of death from HCC for smoking was 9.60 (1.50–61.35) and 1.71(0.58–5.08) among anti-HCV positive and negative individuals, respectively.
Collapse
|
77
|
Sumino H, Ichikawa S, Takahashi T, Sakamoto H, Goto-Onozato K, Koya S, Kanda T, Nara M, Seki K, Murakami M, Kurabayashi M. Conjugated estrogen plus medroxyprogesterone does not impair blood rheological properties in hypertensive postmenopausal women. Maturitas 2006; 53:306-14. [PMID: 16040211 DOI: 10.1016/j.maturitas.2005.05.018] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2004] [Revised: 05/25/2005] [Accepted: 05/27/2005] [Indexed: 11/24/2022]
Abstract
OBJECTIVES Hypertension and estrogens are both prothrombotic. We used the microchannel method to investigate whether hormone replacement therapy (HRT) with conjugated equine estrogen (CEE) plus medroxyprogesterone acetate (MPA) affects blood flow through the microchannels in hypertensive postmenopausal women being treated with antihypertensive drugs and in normotensive postmenopausal women. METHODS Sixty-two consecutive postmenopausal women were randomly assigned to a hypertensive HRT group (n=16), hypertensive control group (n=15), normotensive HRT group (n=16) and normotensive control group (n=15). Each HRT group received CEE 0.625 mg plus MPA 2.5 mg daily orally for 12 months. Both hypertensive groups were being treated with antihypertensive drugs before the study. Microvascular blood flow was assessed on the basis of blood passage time, the time required for 100 microl of whole blood to pass through a cylinder, was determined before and 12 months after the start of HRT by the microchannel method (micro channel array flow analyzer). RESULTS CEE plus MPA therapy did not change blood passage time in any of the groups. Microscopic observation showed that the whole blood passed smoothly through the microchannels in every group. CONCLUSIONS CEE plus MPA therapy may not impair blood flow through the microchannels in hypertensive postmenopausal women receiving antihypertensive drugs or in normotensive postmenopausal women. However, administration of CEE plus MPA to postmenopausal women with hypertension warrants caution against the occurrence of thromboembolic events.
Collapse
|
78
|
Ichikawa S, Johnson ML, Koller DL, Lai D, Xuei X, Edenberg HJ, Hui SL, Foroud TM, Peacock M, Econs MJ. Polymorphisms in the bone morphogenetic protein 2 (BMP2) gene do not affect bone mineral density in white men or women. Osteoporos Int 2006; 17:587-92. [PMID: 16432645 DOI: 10.1007/s00198-005-0018-5] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2005] [Accepted: 09/30/2005] [Indexed: 10/25/2022]
Abstract
INTRODUCTION Peak bone mineral density (BMD) achieved during adulthood is a major determinant of osteoporotic fracture in later life. Although environmental factors affect peak BMD, it is a highly heritable trait. Recently, bone morphogenetic protein 2 (BMP2) was reported as a susceptibility gene for osteoporotic fractures and low BMD in Icelandic and Danish populations. METHODS To determine whether polymorphisms in the BMP2 gene contribute to BMD variation in our population of healthy American whites, we tested seven single nucleotide polymorphisms (SNPs), four of which were associated with osteoporotic phenotypes in the previous study. BMD at the femoral neck and lumbar spine (L2-L4) were measured by dual energy X-ray absorptiometry (DXA) in 411 men (age 18-61) and 1,291 pre-menopausal women (age 20-50). SNP genotypes/haplotypes were tested for population-based association with BMD using analysis of variance. RESULTS None of the polymorphisms tested reached statistical significance (all p values >0.05) for BMD at the femoral neck or lumbar spine in either gender. Two of the SNP haplotypes spanning the entire BMP2 gene were marginally associated with BMD in men (p values=0.019-0.043). However, these haplotypes would account for only a small, if any, portion of BMD variation and would not be significant after adjustment for multiple comparisons. CONCLUSIONS These results demonstrate that genetic variations in BMP2 do not substantially contribute to BMD variation in our population of healthy American whites.
Collapse
|
79
|
Kurozawa Y, Ogimoto I, Shibata A, Nose T, Yoshimura T, Suzuki H, Sakata R, Fujita Y, Ichikawa S, Iwai N, Tamakoshi A. Coffee and risk of death from hepatocellular carcinoma in a large cohort study in Japan. Br J Cancer 2005; 93:607-10. [PMID: 16091758 PMCID: PMC2361599 DOI: 10.1038/sj.bjc.6602737] [Citation(s) in RCA: 86] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023] Open
Abstract
We examined the relation between coffee drinking and hepatocellular carcinoma (HCC) mortality in the Japan Collaborative Cohort Study for Evaluation of Cancer Risk (JACC Study). In total, 110 688 cohort members (46 399 male and 64 289 female subjects) aged 40–79 years were grouped by coffee intake into three categories: one or more cups per day, less than one cup per day and non-coffee drinkers. Cox proportional hazards model by SAS was used to obtain hazard ratio of HCC mortality for each coffee consumption categories. The hazard ratios were adjusted for age, gender, educational status, history of diabetes and liver diseases, smoking habits and alcohol. The hazard ratio of death due to HCC for drinkers of one and more cups of coffee per day, compared with non-coffee drinkers, was 0.50 (95% confidence interval 0.31–0.79), and the ratio for drinkers of less than one cup per day was 0.83 (95% confidence interval 0.54–1.25). Our data confirmed an inverse association between coffee consumption and HCC mortality.
Collapse
|
80
|
Kasama S, Toyama T, Hatori T, Sumino H, Kumakura H, Takayama Y, Ichikawa S, Suzuki T, Kurabayashi M. Comparative effects of valsartan and enalapril on cardiac sympathetic nerve activity and plasma brain natriuretic peptide in patients with congestive heart failure. Heart 2005; 92:625-30. [PMID: 16159967 PMCID: PMC1860905 DOI: 10.1136/hrt.2005.062463] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
OBJECTIVE To evaluate the effects of valsartan on cardiac sympathetic nerve activity, plasma brain natriuretic peptide (BNP) concentration, cardiac function, and symptoms in patients with congestive heart failure (CHF) by comparison with those of enalapril. METHODS 50 patients with CHF (left ventricular ejection fraction (LVEF) < 40%) were randomly assigned to valsartan (80 mg/day; n = 25) or enalapril (5 mg/day; n = 25). All patients were also treated with a loop diuretic. The delayed heart to mediastinum count (H/M) ratio, delayed total defect score (TDS), and washout rate were determined from (123)I-meta-iodobenzylguanidine (MIBG) images. Plasma BNP concentrations were measured before and after six months of treatment. The left ventricular end diastolic volume (LVEDV) and LVEF were also determined by echocardiography. RESULTS In patients receiving valsartan, TDS decreased from a mean (SD) of 43 (8) to 39 (10) (p < 0.01), H/M ratio increased from 1.70 (0.17) to 1.78 (0.22) (p < 0.05), washout rate decreased from 46 (11)% to 41 (10)% (p < 0.05), and plasma BNP concentration decreased from 237 (180) pg/ml to 143 (93) pg/ml (p < 0.05). In addition, LVEDV decreased from 172 (42) ml to 151 (45) ml (p < 0.05) and LVEF increased from 31 (7)% to 39 (10)% (p < 0.001). However, these parameters did not change significantly in patients receiving enalapril. CONCLUSION Plasma BNP concentration and (123)I-MIBG scintigraphic and echocardiographic parameters improved significantly after six months of treatment with valsartan. These findings indicate that valsartan can improve cardiac sympathetic nerve activity and left ventricular performance in patients with CHF.
Collapse
|
81
|
Asai M, Tsukada K, Sakama M, Ichikawa S, Ishii T, Nagame Y, Nishinaka I, Akiyama K, Osa A, Oura Y, Sueki K, Shibata M. Experimental identification of spin-parities and single-particle configurations in 257No and its alpha-decay daughter 253Fm. PHYSICAL REVIEW LETTERS 2005; 95:102502. [PMID: 16196924 DOI: 10.1103/physrevlett.95.102502] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2005] [Indexed: 05/04/2023]
Abstract
alpha-gamma and alpha-electron coincidence spectroscopy for a short-lived heavy actinide nucleus (257)No (T(1/2) = 24.5 s) has been performed using a gas-jet transport system and an on-line isotope separator. Spin-parities of excited states in (253)Fm fed by the alpha decay of (257)No have been identified on the basis of the measured internal conversion coefficients. The nu3/2(+)[622] configuration has been assigned to the ground state of (257)No as well as to the 124.1 keV level in (253)Fm. It was found that the ground-state configuration of (257)No is different from that of lighter N = 155 isotones.
Collapse
|
82
|
Harada M, Ichikawa S, Otsuka A, Hattori M, Hashimoto S. Durability Study on Si-SiC Material for DPF (3). ACTA ACUST UNITED AC 2005. [DOI: 10.4271/2005-01-0582] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
83
|
Linneweber J, Nonaka K, Ichikawa S, Ishitoya H, Motomura T, Nosé Y. Current status on the development of a totally implantable biventricular assist device: the Baylor Gyro BVAD. Thorac Cardiovasc Surg 2004; 52:1-5. [PMID: 15002068 DOI: 10.1055/s-2004-815796] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
OBJECTIVE The Baylor Gyro BVAD is under development with the final goal of establishing a totally implantable biventricular assist system (BVAD). The aim of this study was to evaluate the safety, reliability, and effectiveness of the device in a long-term in vivo model. METHODS The BVAD was implanted into eight calves for longer than 4 weeks in a biventricular bypass fashion, with the native heart remaining. Pump performance was assessed with the system's digital data acquisition unit. Postoperatively, anticoagulation was maintained with i.v. heparin perfusion (ACT< or = 250 sec) gradually replaced by coumadin. Treadmill exercise tests were performed daily following a 10-day reconvalescence period after surgery. RESULTS The animals were kept alive for 37-90 days. The pumps yielded average flows of 5.3 +/- 1.1 l/min and 4.9 +/- 0.7 l/min for the LVAD and RVAD, respectively. Power consumption was 8.2 +/- 2.7 W and 9.6 +/- 4.7 W at 1935 +/- 123 rpm and 2015 +/- 365 rpm, respectively. All cases exhibited low hemolysis; renal and liver function were kept normal throughout the experiments. The animals demonstrated no thromboembolic neurological symptoms and tolerated moderate treadmill exercise. CONCLUSION The Baylor Gyro BVAD demonstrated effective and reliable in vivo performance with acceptable biocompatibility. Based on these studies, we conclude that the system will be suitable as a long-term totally implantable BVAD for uses intended for longer than two years.
Collapse
|
84
|
Sumino H, Takahashi T, Itoh T, Kusaka K, Yamakawa J, Ichikawa S, Kurabayashi M, Kanda T. Plasma Adiponectin Levels in Post-menopausal Women Receiving Hormone Replacement Therapy. J Int Med Res 2004; 32:639-45. [PMID: 15587758 DOI: 10.1177/147323000403200609] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
This study aimed to evaluate the correlation between plasma adiponectin levels and plasma lipid and lipoprotein levels in post-menopausal women (PMW) receiving hormone replacement therapy (HRT). Various clinical and biochemical parameters, including plasma lipid and lipoprotein concentrations and adiponectin levels, were measured in 54 healthy PMW before and after 3 and 6 months of HRT. Control groups consisted of women aged < 40 years ( n = 20) or > 60 years ( n = 17). PMW had significantly lower baseline adiponectin levels compared with the younger or older control groups, but adiponectin concentrations were not significantly altered after 3 or 6 months of HRT. Adiponectin levels in PMW were positively correlated with plasma high-density lipoprotein-cholesterol levels and were negatively correlated with body mass index and triglyceride levels. Our data suggest that circulating adiponectin may contribute to lipid homeostasis in PMW. Further studies are needed to elucidate the effects of HRT and oestrogen on adiponectin levels.
Collapse
|
85
|
Takeuchi Y, Ichikawa S, Konuma A, Tomaru N, Niiyama K, Lee SL, Muhammad N, Tsumura Y. Comparison of the fine-scale genetic structure of three dipterocarp species. Heredity (Edinb) 2004; 92:323-8. [PMID: 14735142 DOI: 10.1038/sj.hdy.6800411] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
We investigated the fine-scale genetic structure of three tropical-rainforest trees, Hopea dryobalanoides, Shorea parvifolia and S. acuminata (Dipterocarpaceae), in Peninsular Malaysia, all of which cooccurred within a 6-ha plot in Pasoh Forest Reserve. A significant genetic structure was found in H. dryobalanoides, weaker (but still significant) genetic structure in S. parvifolia and nonsignificant structure in S. acuminata. Seeds of all three species are wind dispersed, and their flowers are thought to be insect pollinated. The most obvious difference among these species is their height: S. parvifolia and S. acuminata are canopy species, whereas H. dryobalanoides is a subcanopy species. Clear differences were also found among these species in their range of seed dispersal, which depends on the height of the release point; so taller trees disperse their seed more extensively. The estimates of seed dispersal area were consistent with the degree of genetic structure found in the three species. Therefore, tree height probably had a strong influence on the fine-scale genetic structure of the three species.
Collapse
|
86
|
Nishimura I, Ichikawa S, Mikami M, Ishitoya H, Motomura T, Kawamura M, Linneweber J, Glueck J, Shinohara T, Nosé Y, Nishimura I. Evaluation of floating impeller phenomena in a gyro centrifugal pump. ASAIO J 2004; 49:744-7. [PMID: 14655746 DOI: 10.1097/01.mat.0000093962.97611.01] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
The Gyro centrifugal pump, developed as a totally implantable artificial heart, was designed with a free impeller in which the rotational shaft (male bearing) of the impeller was completely separated from the female bearing. For this type of pump, it is very important to keep the proper magnet balance (impeller-magnet and actuator-magnet balance) to prevent thrombus formation or bearing wear. When the magnet balance is not proper, the impeller is jerked down into the bottom bearing. On the other hand, if magnet balance is proper, the impeller is lifted off the bottom of the pump housing within a certain range of pumping conditions. In this study, this floating phenomenon was investigated in detail. The floating phenomenon was proven by observation of the impeller behavior by means of a transparent acrylic pump. The impeller floating phenomenon was mapped on a pump performance curve. The impeller floating phenomenon is affected by the magnet-magnet coupling distance and the rotational speed of the impeller. To keep the proper magnet balance and to maintain the impeller floating phenomenon at the driving conditions of right and left pumps, the magnet-magnet coupling distance was altered by a spacer that was installed between the pump and actuator. It became clear that the same pump could handle different conditions (right and left ventricular assist) by changing the thickness of the spacer. When magnet balance is proper, the floating impeller phenomenon occurs automatically in response to the impeller revolution. This is called "the dynamic revolutions per minute suspension."
Collapse
|
87
|
Shimada K, Kimura K, Ichikawa S, Ohta H, Aoki K. Phenomenon of labyrinth seal with low static pressure difference and large clearance. J Vis (Tokyo) 2004. [DOI: 10.1007/bf03181486] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
88
|
Sumino H, Ichikawa S, Yoshida A, Murakami M, Kanda T, Mizunuma H, Sakamaki T, Kurabayashi M. Effects of hormone replacement therapy on weight, abdominal fat distribution, and lipid levels in Japanese postmenopausal women. Int J Obes (Lond) 2003; 27:1044-51. [PMID: 12917709 DOI: 10.1038/sj.ijo.0802371] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
OBJECTIVE To investigate the effects of hormone replacement therapy (HRT) on weight, abdominal fat distribution, and fasting lipid levels in Japanese postmenopausal women (PMW). DESIGN Prospective, 12-month-controlled clinical comparison of women with and without HRT. SUBJECTS In all, 35 PMW with HRT (conjugated estrogens, 0.625 mg daily; medroxyprogesterone acetate, 2.5 mg daily; HRT group) and 26 PMW without HRT (control group). MEASUREMENTS Weight, abdominal fat distribution by computed tomographic measurements, lipid profiles, and sex hormones were determined at baseline and after 12 months of treatment or observation. RESULTS Weight did not change in any group. Visceral abdominal fat increased in controls, but not in the HRT group. Total and low-density lipoprotein cholesterol decreased, and triglyceride (TG) and high-density lipoprotein cholesterol increased in the HRT group; these did not change in the control group. When we divided women into those with android and gynoid types of abdominal fat distribution. Subjects with an android distribution showed reduced visceral fat with HRT, which also decreased the proportion of patients maintaining an android distribution. HRT did not alter abdominal fat distribution in subjects with a gynoid distribution. HRT increased serum TG in the android and the gynoid subgroups. CONCLUSION Improved distribution of abdominal fat and fasting lipid levels except for TG may represent beneficial effects of HRT with respect to cardiovascular disease, but caution is warranted concerning TG elevation from HRT performed in PMW.
Collapse
|
89
|
Kosaka R, Yanagi K, Sato T, Ishitoya H, Ichikawa S, Motomura T, Kawahito S, Mikami M, Linneweber J, Nonaka K, Takano T, Glueck J, Sankai Y, Nosè Y. Operating point control system for a continuous flow artificial heart: in vitro study. ASAIO J 2003; 49:259-64. [PMID: 12790373 DOI: 10.1097/01.mat.0000065376.28871.a8] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
We proposed and developed a practical and effective servo control system for rotary blood pumps. A rotary blood pump for assisting the failing natural heart should be operated only in physiologically acceptable conditions. The operation of a rotary blood pump is based on the rotational speed of the impeller and pressure head. If the pump flow and the pressure head are set within an acceptable range, the driving condition is deemed normal condition, and this control system maintains the preset operating point by applying proportional and detective control (PD control). If the pump flow or pressure head is outside the acceptable range, the driving condition is determined to be abnormal condition, and this system operates the pump in a recovery fashion. If the driving condition is kept under abnormal conditions of sudden decrease of the flow, the condition is termed a suction condition. The controller releases the pump from the suction condition and later returns it to the normal condition. In this study, we evaluated these servo control modes of the centrifugal pump and confirmed whether the performance of this proposed operating point control system was practical.
Collapse
|
90
|
Uchida Y, Ichikawa S, Harada T, Hamanaka T. Durability Study on Si-SiC Material for DPF. ACTA ACUST UNITED AC 2003. [DOI: 10.4271/2003-01-0384] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
91
|
Kasama S, Toyama T, Kumakura H, Takayama Y, Ichikawa S, Suzuki T, Kurabayashi M. Low-dose dobutamine stress 99mTc tetrofosmin quantitative gated SPECT performed during the acute phase of myocardial infarction predicts subsequent myocardial viability and detects stunned myocardium. Nucl Med Commun 2003; 24:167-74. [PMID: 12548041 DOI: 10.1097/00006231-200302000-00009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
This study evaluated the ability of low-dose dobutamine stress 99mTc tetrofosmin (DSTF) quantitative gated single photon emission computed tomography (QGS) performed during the acute phase of myocardial infarction to predict subsequent myocardial viability and detect stunned myocardium. Twenty-four patients suffering their first acute myocardial infarction (AMI) underwent coronary angioplasty after coronary angiography (CAG) immediately following admission. Follow-up CAG and left ventriculography (LVG) were performed 10 days and 6 months later. All patients underwent DSTF QGS to measure left ventricular ejection fraction (LVEF) at rest and during dobutamine infusion (10 microg.kg(-1).min(-1)) 14 days after angioplasty. No patient suffered coronary restenosis. After 6 months, the LVEF measured by LVG improved >5% in 12 patients (group A), and did not improve in the remaining 12 patients (group B). The culprit coronary artery, the peak serum creatine phosphokinase concentration, the recanalization time, and the LVEF during the acute phase were similar in the two groups. However, the increase in the LVEF was greater in group A than in group B during dobutamine infusion (deltaLVEF) as measured by DSTF QGS (11.2+/-3.8% vs 2.9+/-4.7%, P <0.001). If a cut-off value of 6.5% for the deltaLVEF was used to predict the improvement in LVEF during the chronic phase, then the sensitivity of this test was 83.3% and its specificity was 83.3%. It is concluded that DSTF QGS during AMI can be used to predict myocardial viability and detect stunned myocardium.
Collapse
|
92
|
Maruyama T, Kaji D, Kaneko T, Goto S, Tsukada K, Haba H, Asai M, Ichikawa S, Nagame Y, Kudo H. J Radioanal Nucl Chem 2003; 255:253-256. [DOI: 10.1023/a:1022571813231] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
93
|
Toyoshima A, Tsukada K, Haba H, Asai M, Goto S, Akiyama K, Nishinaka I, Ichikawa S, Nagame Y, Shinohara A. J Radioanal Nucl Chem 2003; 255:485-487. [DOI: 10.1023/a:1022520113173] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
94
|
Goto S, Kaji D, Nishinaka I, Nagame Y, Ichikawa S, Tsukada K, Asai M, Haba H, Mitsuoka S, Nishio K, Sakama M, Zhao YL, Sueki K, Tanikawa K, Takamiya,6 K, Kudo H, Nakahara H. J Radioanal Nucl Chem 2003; 255:73-76. [DOI: 10.1023/a:1022271529219] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
95
|
Niinami H, Takeuchi Y, Ichikawa S, Ban T, Higashita R, Suda Y, Yamamoto M. [Multivessel off-pump coronary aortic bypass grafting with an impaired and severely dilated left ventricle using the Starfish heart positioner]. KYOBU GEKA. THE JAPANESE JOURNAL OF THORACIC SURGERY 2002; 55:773-7. [PMID: 12174622] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/26/2023]
Abstract
Off-pump coronary artery bypass grafting (OPCAB) is gaining acceptance and is now more widely used for coronary revascularization worldwide. Accessing the vessels, particularly on the lateral and inferior walls of the heart, can sometimes be challenging while the heart is beating, especially in hearts with an impaired and severely dilated left ventricle. The Starfish heart positioner was designed to achieve optimal exposure of the lateral and inferior walls of the heart with minimal hemodynamic compromise. This device was used in a patient with a severely impaired and dilated left ventricle to successfully position the heart for quadruple bypass grafting using all in situ arterial grafts, such as bilateral international thoracic arteries (ITAs) and the right gastroepiploic artery. The degree of hematoma caused by the pressure of the suction cup of this device was minimal. This case report suggests that the use of Starfish heart positioner will facilitate and expand the ability of surgeons to easily and consistently perform OPCAB.
Collapse
|
96
|
Suda Y, Otsuka K, Niinami H, Ichikawa S, Ban T, Higashita R, Takeuchi Y. Changes in ultra-low and very low frequency heart rate variability after coronary artery bypass grafting. Biomed Pharmacother 2002; 55 Suppl 1:110s-114s. [PMID: 11774857 DOI: 10.1016/s0753-3322(01)90015-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
This study was performed to assess the effects of coronary artery bypass grafting (CABG) on the ultra-low (ULF) and very low (VLF) frequency components of heart rate variability (HRV). Forty-nine CABG patients (aged from 38 to 77 years) were examined by 24-h ambulatory electrocardiographic (AECG) monitoring, both preoperatively and 4 weeks after CABG. HRV spectral components were obtained by maximum entropy method analysis. Then the ULF, VLF, low frequency (LF), high frequency (HF) and total frequency (TF) components were compared before and after CABG. The average 24-h heart rate increased significantly after CABG (69+/-11.5 vs 82.9+/-10.9 beats per minute [bpm], P < 0.0001). The power of the ULF, VLF, and LF spectral components showed a decrease after surgery (2,859.9 vs 1,601.2 ms2, P<0.0001, 1,215.0 vs 572.3 ms2, P<0.0001, and 260.3 vs 125.9 ms2, P< 0.002, respectively), but the HF power did not show any significant change (98.7 vs 125.9 ms2, NS). Analysis of the normalized ratio of the ULF component (ULF/TF ratio) revealed a significant increase postoperatively (0.6496+/-0.0931 vs 0.7003+/-0.1338, P < 0.0001), but the VLF/TF and LF/TF ratios decreased after CABG (from 0.2671+/-0.0689 to 0.2040+/-0.0832, P< 0.0001 and from 0.0568+/-0.0290 to 0.0429+/-0.0232, P< 0.0088, respectively). In contrast, there was no significant alteration in the HF/TF ratio. These results suggest that recovery of cardiac autonomic activity is delayed after surgery. However, improvement of the ULF/TF ratio, one of the prognostic indicators for patients with cardiac disease, should be related to the relief of myocardial ischemia by CABG.
Collapse
|
97
|
Iwamoto K, Ikeda J, Nito M, Kosaka N, Ichikawa S, Ohmori K, Sakai K. Effect of oxatomide, an antiallergic agent, on QT interval in dogs. ARZNEIMITTEL-FORSCHUNG 2002; 51:971-6. [PMID: 11799844 DOI: 10.1055/s-0031-1300147] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
Oxatomide (CAS 60607-34-3, KW-4354) is an effective antiallergic agent for allergic rhinitis, urticaria, pruritus cutaneous, and eczema/dermatitis, etc. Terfenadine (CAS 50679-08-8) and astemizole (CAS 68844-77-9), antiallergic agents, have been reported to induce QT prolongation leading to serious ventricular arrhythmia (torsades de pointes) as cardiovascular adverse effects. The present study was carried out to determine whether oxatomide and terfenadine have effects on QT interval as a single drug or in combination with itraconazole (CAS 84625-61-6), an antifungal agent with a CYP3A4 inhibitory effect, in conscious dogs. Terfenadine alone induced QT prolongation at the dose of 30 mg/kg p.o. When itraconazole was administered at the dose of 100 mg/kg p.o. 1 h before terfenadine administration, terfenadine induced QT prolongation at the dose of 10 mg/kg p.o. On the other hand, oxatomide did not induce QT prolongation either as a single agent at the dose of 30 mg/kg p.o. or in combination with itraconazole at the dose of 10 mg/kg p.o. The results present no evidence that oxatomide has the potential to provoke ventricular arrhythmia.
Collapse
|
98
|
Nagame Y, Asai M, Haba H, Tsukada K, Goto S, Sakama M, Nishinaka I, Toyoshima A, Akiyama K, Ichikawa S. Status and Prospects of Heavy Element Nuclear Chemistry Research at JAERI. ACTA ACUST UNITED AC 2002. [DOI: 10.14494/jnrs2000.3.129] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
99
|
Nagame Y, Asai M, Haba H, Goto S, Tsukada K, Nishinaka I, Nishio K, Ichikawa S, Toyoshima A, Akiyama K, Nakahara H, Sakama M, Sch^|^auml;adl M, Kratz JV, G^|^auml;ggeler HW, T^|^uuml;rler A. Production Cross Sections of 261Rf and 262Db in Bombardments of 248Cm with 18O and 19F Ions. ACTA ACUST UNITED AC 2002. [DOI: 10.14494/jnrs2000.3.85] [Citation(s) in RCA: 59] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
100
|
Asai M, Sakama M, Tsukada K, Ichikawa S, Haba H, Nishinaka I, Nagame Y, Goto S, Akiyama K, Toyoshima A, Kojima Y, Oura Y, Nakahara H, Shibata M, Kawade K. Decay Studies of Neutron-deficient Am, Cm, and Bk Nuclei Using an On-line Isotope Separator. ACTA ACUST UNITED AC 2002. [DOI: 10.14494/jnrs2000.3.187] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|