76
|
Silva MO, Kirkwood N, Mulvaney P, Ellis AV, Stok KS. Evaluation of a lanthanide nanoparticle-based contrast agent for microcomputed tomography of porous channels in subchondral bone. J Orthop Res 2023; 41:447-458. [PMID: 35524421 PMCID: PMC10084061 DOI: 10.1002/jor.25361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Revised: 04/10/2022] [Accepted: 05/05/2022] [Indexed: 02/04/2023]
Abstract
Osteoarthritis (OA) is a chronic joint disease that causes disability and pain. The osteochondral interface is a gradient tissue region that plays a significant role in maintaining joint health. It has been shown that during OA, increased neoangiogenesis creates porous channels at the osteochondral interface allowing the transport of molecules related to OA. Importantly, the connection between these porous channels and the early stages of OA development is still not fully understood. Microcomputed tomography (microCT) offers the ability to image the porous channels at the osteochondral interface, however, a contrast agent is necessary to delineate the different X-ray attenuations of the tissues. In this study BaYbF5 -SiO2 nanoparticles are synthesized and optimized as a microCT contrast agent to obtain an appropriate contrast attenuation for subsequent segmentation of structures of interest, that is, porous channels, and mouse subchondral bone. For this purpose, BaYbF5 nanoparticles were synthesized and coated with a biocompatible silica shell (SiO2 ). The optimized BaYbF5 -SiO2 27 nm nanoparticles exhibited the highest average microCT attenuation among the biocompatible nanoparticles tested. The BaYbF5 -SiO2 27 nm nanoparticles increased the mean X-ray attenuation of structures of interest, for example, porous channel models and mouse subchondral bone. The BaYbF5 -SiO2 contrast attenuation was steady after diffusion into mouse subchondral bone. In this study, we obtained for the first time, the average microCT attenuation of the BaYbF5 -SiO2 nanoparticles into porous channel models and mouse subchondral bone. In conclusion, BaYbF5 -SiO2 nanoparticles are a potential contrast agent for imaging porous channels at the osteochondral interface using microCT.
Collapse
|
77
|
Investigation of the Effects of Stress Hyperglycemia Ratio and Preoperative Computed Tomographic Angiography on the Occurrence of Acute Kidney Injury in Diabetic Patients following Surgical Thromboembolectomy. Tomography 2023; 9:255-263. [PMID: 36828372 PMCID: PMC9967571 DOI: 10.3390/tomography9010020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2022] [Revised: 01/22/2023] [Accepted: 01/25/2023] [Indexed: 01/31/2023] Open
Abstract
Acute lower extremity ischemia (ALI) is a cardiovascular emergency resulting from embolic and thrombotic causes. Although endovascular techniques have advanced, surgical thromboembolectomy is still the gold standard. Emergency thromboembolectomy surgery involves an ischemia-reperfusion injury, which also poses a risk for acute renal injury (AKI). The stress hyperglycemia rate (SHR) has recently emerged as an important prognostic value in emergency cardiovascular events. In the present study, we aimed to analyze the impact of preoperative contrast-enhanced tomographic angiography (CTA) and the SHR value on postoperative AKI in emergency thromboembolectomy procedures in patients with insulin-dependent diabetes mellitus (DM). In this retrospective analysis, patients with DM who received emergency surgical thromboembolectomy after being hospitalized at our hospital with ALI between 20 October 2015, and 10 September 2022, were included. Patients were classified into two groups: Group 1 (N = 159), who did not develop AKI, and Group 2 (N = 45), who did. The 45 patients in Group 2 and the 159 patients in Group 1 had median ages of 59 (39-90) and 66 (37-93), respectively (p = 0.008). The percentage of patients in Group 2 with Rutherford class IIB and admission times longer than 6 h was higher (p = 0.003, p = 0.027, respectively). To determine the variables affecting AKI after surgical embolectomy procedures, multivariate logistic regression analysis was used. In multivariate analysis Model 1, age > 65 years (odds ratio [OR]: 1.425, 95% confidence interval [CI]: 1.230-1.980, p < 0.001), preoperative high creatinine (OR: 4.194, 95% CI: 2.890-6.156, p = 0.003), and Rutherford class (OR: 0.874, 95% CI: 0.692-0.990, p = 0.036) were determined as independent predictors for AKI. In Model 2, age > 65 years (OR: 1.224 CI: 1.090-1.679, p = 0.014), preoperative high creatinine (OR: 3.975, 95% CI: 2.660-5.486, p = 0.007), and SHR (OR: 2.142, CI: 1.134-3.968, p = 0.003), were determined as independent predictors for amputation. In conclusion, when an emergency thromboembolectomy operation is planned in insulin-dependent DM patients, renal risky groups can be identified, and renal protective measures can be taken. In addition, to reduce the renal risk, according to the suitability of the clinical conditions of the patients, the decision to perform a CTA with contrast can be taken by looking at the SHR value.
Collapse
|
78
|
Arsalani S, Arsalani S, Isikawa M, Guidelli EJ, Mazon EE, Ramos AP, Bakuzis A, Pavan TZ, Baffa O, Carneiro AAO. Hybrid Nanoparticles of Citrate-Coated Manganese Ferrite and Gold Nanorods in Magneto-Optical Imaging and Thermal Therapy. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:434. [PMID: 36770395 PMCID: PMC9921964 DOI: 10.3390/nano13030434] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/11/2022] [Revised: 01/11/2023] [Accepted: 01/13/2023] [Indexed: 06/18/2023]
Abstract
The development of nanomaterials has drawn considerable attention in nanomedicine to advance cancer diagnosis and treatment over the last decades. Gold nanorods (GNRs) and magnetic nanoparticles (MNPs) have been known as commonly used nanostructures in biomedical applications due to their attractive optical properties and superparamagnetic (SP) behaviors, respectively. In this study, we proposed a simple combination of plasmonic and SP properties into hybrid NPs of citrate-coated manganese ferrite (Ci-MnFe2O4) and cetyltrimethylammonium bromide-coated GNRs (CTAB-GNRs). In this regard, two different samples were prepared: the first was composed of Ci-MnFe2O4 (0.4 wt%), and the second contained hybrid NPs of Ci-MnFe2O4 (0.4 wt%) and CTAB-GNRs (0.04 wt%). Characterization measurements such as UV-Visible spectroscopy and transmission electron microscopy (TEM) revealed electrostatic interactions caused by the opposing surface charges of hybrid NPs, which resulted in the formation of small nanoclusters. The performance of the two samples was investigated using magneto-motive ultrasound imaging (MMUS). The sample containing Ci-MnFe2O4_CTAB-GNRs demonstrated a displacement nearly two-fold greater than just using Ci-MnFe2O4; therefore, enhancing MMUS image contrast. Furthermore, the preliminary potential of these hybrid NPs was also examined in magnetic hyperthermia (MH) and photoacoustic imaging (PAI) modalities. Lastly, these hybrid NPs demonstrated high stability and an absence of aggregation in water and phosphate buffer solution (PBS) medium. Thus, Ci-MnFe2O4_CTAB-GNRs hybrid NPs can be considered as a potential contrast agent in MMUS and PAI and a heat generator in MH.
Collapse
|
79
|
Scorzo AV, Byrd BK, Strawbridge RR, Davis SC. A new candidate agent for fluorescence guided neurosurgery produces high, persistent tumor contrast shortly after administration. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2023; 12361:1236106. [PMID: 38765853 PMCID: PMC11101171 DOI: 10.1117/12.2650599] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2024]
Abstract
Neurosurgical fluorescence guidance relies on contrast agents to identify tumor regions to aid in increasing the extent of resection. Existing contrast agents for this indication each have their own limitation: unpredictable contrast from tumor heterogeneity, significant extravasation into the background brain and long incubation times. An ideal contrast agent should have high and rapid contrast that persists well into the surgical procedure. By using a whole animal hyperspectral cryo-imaging system several CAs were screened for these favorable properties and compared to the gold standard of gadolinium enhanced MR. Herein, we briefly report on the leading candidate Rd-PEG1k, which shows high contrast within minutes of administration that persists for at least 90 minutes.
Collapse
|
80
|
Jiang Z, Zhang M, Li P, Wang Y, Fu Q. Nanomaterial-based CT contrast agents and their applications in image-guided therapy. Theranostics 2023; 13:483-509. [PMID: 36632234 PMCID: PMC9830442 DOI: 10.7150/thno.79625] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Accepted: 12/01/2022] [Indexed: 12/23/2022] Open
Abstract
Computed tomography (CT), a diagnostic tool with clinical application, comprehensive coverage, and low cost, is used in hospitals worldwide. However, CT imaging fails to distinguish soft tissues from normal organs and tumors because their mass attenuation coefficients are similar. Various CT contrast agents have been developed in recent years to improve the sensitivity and contrast of imaging. Here, we review the progress of nanomaterial-based CT contrast agents and their applications in image-guided therapy. The CT contrast agents are classified according to their components; gold (Au)-based, bismuth (Bi)-based, lanthanide (Ln)-based, and transition metal (TM)-based nanomaterials are discussed. CT image-guided therapy of diseases, including photothermal therapy (PPT), photodynamic therapy (PDT), chemotherapy, radiotherapy (RT), gas therapy, sonodynamic therapy (SDT), immunotherapy, starvation therapy, gene therapy (GT), and microwave thermal therapy (MWTT), are reviewed. Finally, the perspectives on the CT contrast agents and their biomedical applications are discussed.
Collapse
|
81
|
Li N, Xue L, Mai X, Wang P, Zhu C, Han X, Xie Y, Wang B, Ge Y, Zhang Y, Sun J. Transfection of clMagR/clCry4 imparts MR-T 2 imaging contrast properties to living organisms ( E. coli) in the presence of Fe 3+ by endogenous formation of iron oxide nanoparticles. Front Mol Biosci 2023; 10:1119356. [PMID: 36876047 PMCID: PMC9981785 DOI: 10.3389/fmolb.2023.1119356] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Accepted: 01/30/2023] [Indexed: 02/19/2023] Open
Abstract
Rapid development of medical imaging, such as cellular tracking, has increased the demand for "live" contrast agents. This study provides the first experimental evidence demonstrating that transfection of the clMagR/clCry4 gene can impart magnetic resonance imaging (MRI) T2-contrast properties to living prokaryotic Escherichia coli (E. coli) in the presence of Fe3+ through the endogenous formation of iron oxide nanoparticles. The transfected clMagR/clCry4 gene markedly promoted uptake of exogenous iron by E. coli, achieving an intracellular co-precipitation condition and formation of iron oxide nanoparticles. This study will stimulate further exploration of the biological applications of clMagR/clCry4 in imaging studies.
Collapse
|
82
|
CT and MRI Imaging of Theranostic Bimodal Fe 3O 4@Au NanoParticles in Tumor Bearing Mice. Int J Mol Sci 2022; 24:ijms24010070. [PMID: 36613511 PMCID: PMC9820463 DOI: 10.3390/ijms24010070] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Revised: 12/13/2022] [Accepted: 12/16/2022] [Indexed: 12/24/2022] Open
Abstract
Gold-containing nanoparticles are proven to be an effective radiosensitizer in the radiotherapy of tumors. Reliable imaging of nanoparticles in a tumor and surrounding normal tissues is crucial both for diagnostics and for nanoparticle application as radiosensitizers. The Fe3O4 core was introduced into gold nanoparticles to form a core/shell structure suitable for MRI imaging. The aim of this study was to assess the in vivo bimodal CT and MRI enhancement ability of novel core/shell Fe3O4@Au theranostic nanoparticles. Core/shell Fe3O4@Au nanoparticles were synthesized and coated with PEG and glucose. C57Bl/6 mice bearing Ca755 mammary adenocarcinoma tumors received intravenous injections of the nanoparticles. CT and MRI were performed at several timepoints between 5 and 102 min, and on day 17 post-injection. Core/shell Fe3O4@Au nanoparticles provided significant enhancement of the tumor and tumor blood vessels. Nanoparticles also accumulated in the liver and spleen and were retained in these organs for 17 days. Mice did not show any signs of toxicity over the study duration. These results indicate that theranostic bimodal Fe3O4@Au nanoparticles are non-toxic and serve as effective contrast agents both for CT and MRI diagnostics. These nanoparticles have potential for future biomedical applications in cancer diagnostics and beyond.
Collapse
|
83
|
Leone L, Anemone A, Carella A, Botto E, Longo DL, Tei L. A Neutral and Stable Macrocyclic Mn(II) Complex for MRI Tumor Visualization. ChemMedChem 2022; 17:e202200508. [PMID: 36198652 PMCID: PMC10092550 DOI: 10.1002/cmdc.202200508] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Revised: 10/05/2022] [Indexed: 01/14/2023]
Abstract
A stable and inert amphiphilic Mn(II) complex based on a bisamide derivative of 1,4-DO2A (DO2A=tetraazacyclododecane-1,4-diacetic acid) was synthesized and its 1 H NMR relaxometric behavior was investigated as a function of the magnetic field strength, pH and temperature. The interaction with human serum albumin (HSA) was also studied via relaxometry showing a good relaxivity enhancement at low field (at 1T and 298 K the relaxivity increases from 4.5 mM-1 s-1 of the Mn(II)-complex to 14.0 mM-1 s-1 of the complex-HSA supramolecular adduct). In vivo biodistribution and MRI studies highlighted a rapid and mixed renal/liver elimination without spleen accumulation from healthy mice and good contrast enhancing properties in a breast tumor murine model. A comparison with a clinically approved Gd(III) agent (GdBOPTA, Multihance®) underlined that the proposed Mn(II) contrast agent gave comparable tumor contrast enhancement up to 3 hours post-injection.
Collapse
|
84
|
Maruyama H, Tobari M, Nagamatsu H, Shiina S, Yamaguchi T. Contrast-enhanced ultrasonography for the management of portal hypertension in cirrhosis. Front Med (Lausanne) 2022; 9:1057045. [PMID: 36590972 PMCID: PMC9794740 DOI: 10.3389/fmed.2022.1057045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Accepted: 11/16/2022] [Indexed: 12/15/2022] Open
Abstract
Portal hypertension is a major pathophysiological condition in patients with cirrhosis. This accounts for the occurrence and severity of the various manifestations. The degree is determined by the portal pressure or hepatic venous pressure gradients, both of which are obtained by invasive interventional radiological procedures. Ultrasound (US) is a simple and minimally invasive imaging modality for the diagnosis of liver diseases. Owing to the availability of microbubble-based contrast agents and the development of imaging modes corresponding to contrast effects, contrast-enhanced US (CEUS) has become popular worldwide for the detailed evaluation of hepatic hemodynamics, diffuse liver disease, and focal hepatic lesions. Recent advancements in digital technology have enabled contrast-based demonstrations with improved resolution, leading to a wider range of applications. This review article describes the current role, benefits, and limitations of CEUS in the management of portal hypertension.
Collapse
|
85
|
An H, Xie R, Ge Y, Wang T. Progress of CT aortic angiography combined with coronary artery in the evaluation of acute aortic syndrome. Front Cardiovasc Med 2022; 9:1036982. [PMID: 36479572 PMCID: PMC9719981 DOI: 10.3389/fcvm.2022.1036982] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Accepted: 10/12/2022] [Indexed: 09/19/2023] Open
Abstract
Acute aortic syndrome (AAS) is a group of cardiovascular diseases that seriously threaten human life and health. AAS patients are often complicated with coronary artery disease and other related diseases, which require rapid and clear clinical diagnosis to avoid serious adverse events. In recent years, with the progress of science and technology, a variety of computer tomography (CT) angiography techniques have been applied in the clinic, and the diagnosis rate of AAS with coronary heart disease (CAD) has greatly increased. At the same time, the development of surgical technology and endovascular repair technology has significantly reduced the mortality and complication rate of AAS surgery. In the clinical diagnosis of AAS and related diseases, CT aortic angiography (CTA) combined with coronary CTA is increasingly applied to identify related diseases. Here, the current research progress on the technique of aortic CTA combined with coronary CTA is reviewed.
Collapse
|
86
|
Moazami Goudarzi N, Samaro A, Vervaet C, Boone MN. Development of Flow-Through Cell Dissolution Method for In Situ Visualization of Dissolution Processes in Solid Dosage Forms Using X-ray μCT. Pharmaceutics 2022; 14:pharmaceutics14112475. [PMID: 36432667 PMCID: PMC9696340 DOI: 10.3390/pharmaceutics14112475] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Revised: 11/08/2022] [Accepted: 11/10/2022] [Indexed: 11/19/2022] Open
Abstract
Visualization of the dynamic behavior of pharmaceutical dosage forms during the dissolution process offers a better understanding of the drug release mechanism, enabling the design of customized dosage forms. In this study, an X-ray tomography-based approach is proposed to monitor and analyze the dynamics of the structure at the pore scale level during the dissolution process. A flow-through cell dissolution apparatus was developed, capable of mimicking the standard in vitro dissolution process, which can be easily positioned in an X-ray tomography setup. The method was utilized to study the dissolution of a Capa® (polycaprolactone)-based sustained-release 3D printed tablet. The impact of the flow rate on the active pharmaceutical ingredient (API) release rate was studied and 16 mL/min was selected as a suitable flow rate. Furthermore, cesium chloride (CsCl) was used as a contrast agent to increase the contrast between the sample and the dissolution medium. Data obtained with this novel technique were in a good agreement with the released drug rate acquired by the standard in vitro dissolution test (the similarity factor (f2) = 77%). Finally, the proposed approach allowed visualizing the internal structure of the sample, as well as real-time tracking of solution ingress into the product.
Collapse
|
87
|
He C, Zhu J, Zhang H, Qiao R, Zhang R. Photoacoustic Imaging Probes for Theranostic Applications. BIOSENSORS 2022; 12:947. [PMID: 36354456 PMCID: PMC9688356 DOI: 10.3390/bios12110947] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Revised: 10/23/2022] [Accepted: 10/26/2022] [Indexed: 06/16/2023]
Abstract
Photoacoustic imaging (PAI), an emerging biomedical imaging technology, capitalizes on a wide range of endogenous chromophores and exogenous contrast agents to offer detailed information related to the functional and molecular content of diseased biological tissues. Compared with traditional imaging technologies, PAI offers outstanding advantages, such as a higher spatial resolution, deeper penetrability in biological tissues, and improved imaging contrast. Based on nanomaterials and small molecular organic dyes, a huge number of contrast agents have recently been developed as PAI probes for disease diagnosis and treatment. Herein, we report the recent advances in the development of nanomaterials and organic dye-based PAI probes. The current challenges in the field and future research directions for the designing and fabrication of PAI probes are proposed.
Collapse
|
88
|
Misra DP, Jain N, Ora M, Singh K, Agarwal V, Sharma A. Outcome Measures and Biomarkers for Disease Assessment in Takayasu Arteritis. Diagnostics (Basel) 2022; 12:diagnostics12102565. [PMID: 36292253 PMCID: PMC9601573 DOI: 10.3390/diagnostics12102565] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2022] [Revised: 10/16/2022] [Accepted: 10/18/2022] [Indexed: 12/05/2022] Open
Abstract
Takayasu arteritis (TAK) is a less common large vessel vasculitis where histopathology of involved arteries is difficult to access except during open surgical procedures. Assessment of disease activity in TAK, therefore, relies on surrogate measures. Clinical disease activity measures such as the National Institutes of Health (NIH) score, the Disease Extent Index in TAK (DEI.TAK) and the Indian TAK Clinical Activity Score (ITAS2010) inconsistently associate with acute phase reactants (APRs). Computerized tomographic angiography (CTA), magnetic resonance angiography (MRA), or color Doppler Ultrasound (CDUS) enables anatomical characterization of stenosis, dilatation, and vessel wall characteristics. Vascular wall uptake of 18-fluorodeoxyglucose or other ligands using positron emission tomography computerized tomography (PET-CT) helps assess metabolic activity, which reflects disease activity well in a subset of TAK with normal APRs. Angiographic scoring systems to quantitate the extent of vascular involvement in TAK have been developed recently. Erythrocyte sedimentation rate and C-reactive protein have a moderate performance in distinguishing active TAK. Numerous novel biomarkers are under evaluation in TAK. Limited literature suggests a better assessment of active disease by combining APRs, PET-CT, and circulating biomarkers. Validated damage indices and patient-reported outcome measures specific to TAK are lacking. Few biomarkers have been evaluated to reflect vascular damage in TAK and constitute important research agenda.
Collapse
|
89
|
Jin BB, Ma Y, Zhao XH, Teng YL, Zhu SY. Operator's Influence on Contrast Agent Intravasation During Hysterosalpingo-Contrast Sonography: Explanation Based on a Physics Model. Int J Gen Med 2022; 15:7709-7718. [PMID: 36238541 PMCID: PMC9552795 DOI: 10.2147/ijgm.s380917] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2022] [Accepted: 08/26/2022] [Indexed: 11/23/2022] Open
Abstract
Objective To analyze the risk factors of the operators on contrast agent intravasation during hysterosalpingo-contrast sonography (HyCoSy). Methods We retrospectively collected 399 infertile women who underwent HyCoSy by the same sonographer. These patients were divided into two groups according to the way how the assistants connected the syringe to the uterus radiography catheter to inject the contrast agent. We analyzed whether the use of different contrast bolus injection methods had any influence on the incidence of intravasation during HyCoSy. Results There was no significant difference between the two groups with different cross-sectional areas of the syringe outflow tract in the risk variables for intravasation, but the intravasation rates of the two groups were different, 26.4% in group A and 17.1% in group B, P <0.05. The primary manifestation was that when both fallopian tubes were unobstructed, the intravasation rate of group B with smaller cross-sectional area of the outflow tract of the syringe was lower, and the difference was statistically significant. The inferences drawn from our physics model were also in line with the clinical results. Conclusion The influence of different operators on the contrast agent intravasation rate of HyCoSy cannot be ignored. The assistants of HyCoSy examination should inject the contrast agent slowly and steady, and a needle can be used as a flow restrictor to control the flow into the uterine cavity per unit time, slow down the rising speed of intrauterine pressure, and avoid the accumulation of contrast agent in the uterine cavity, so as to reduce the intravasation caused by operator factors.
Collapse
|
90
|
Li Y, Gao S, Jiang H, Ayat N, Laney V, Nicolescu C, Sun W, Tweedle MF, Lu ZR. Evaluation of Physicochemical Properties, Pharmacokinetics, Biodistribution, Toxicity, and Contrast-Enhanced Cancer MRI of a Cancer-Targeting Contrast Agent, MT218. Invest Radiol 2022; 57:639-654. [PMID: 35703463 PMCID: PMC9444296 DOI: 10.1097/rli.0000000000000881] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Accepted: 03/12/2022] [Indexed: 01/03/2023]
Abstract
OBJECTIVES Preclinical assessments were performed according to the US Food and Drug Administration guidelines to determine the physicochemical properties, pharmacokinetics, clearance, safety, and tumor-specific magnetic resonance (MR) imaging of MT218, a peptidic gadolinium-based MR imaging agent targeting to extradomain B fibronectin for MR molecular imaging of aggressive tumors. MATERIALS AND METHODS Relaxivity, chelation stability, binding affinity, safety-related target profiling, and effects on CYP450 enzymes and transporters were evaluated in vitro. Magnetic resonance imaging was performed with rats bearing prostate cancer xenografts, immunocompetent mice bearing murine pancreatic cancer allografts, and mice bearing lung cancer xenografts at different doses of MT218. Pharmacological effects on cardiovascular, respiratory, and central nervous systems were determined in rats and conscious beagle dogs. Pharmacokinetics were tested in rats and dogs. Biodistribution and excretion were studied in rats. Single and repeated dosing toxicity was evaluated in rats and dogs. In vitro and in vivo genotoxicity, in vitro hemolysis, and anaphylactic reactivity were also performed. RESULTS At 1.4 T, the r1 and r2 relaxivities of MT218 were 5.43 and 7.40 mM -1 s -1 in pure water, 6.58 and 8.87 mM -1 s -1 in phosphate-buffered saline, and 6.54 and 8.70 mM -1 s -1 in aqueous solution of human serum albumin, respectively. The binding affinity of MT218 to extradomain B fragment is 3.45 μM. MT218 exhibited no dissociation of the Gd(III) chelates under physiological conditions. The peptide degradation half-life ( t1/2 ) of MT218 was 1.63, 5.85, and 2.63 hours in rat, dog, and human plasma, respectively. It had little effect on CYP450 enzymes and transporters. MT218 produced up to 7-fold increase of contrast-to-noise ratios in the extradomain B fibronectin-rich tumors with a dose of 0.04 mmol/kg for at least 30 minutes. MT218 had little pharmacological effect on central nervous, cardiovascular, or respiratory systems. MT218 had a mean plasma elimination half-life ( t1/2 ) of 0.31 and 0.89 hours in rats and dogs at 0.1 mmol/kg, respectively. No detectable Gd deposition was observed in the brain at 6 hours postinjection of MT218 at 0.1 mmol/kg in rats. MT218 was not mutagenic and had no mortality or morbidity in the rats or dogs up to 1.39 and 0.70 mmol/kg/d, respectively. The no observed adverse effect level of MT218 in Sprague-Dawley rats was 1.39 mmol/kg for single dosing and 0.46 mmol/kg/d for repeated dosing. The no observed adverse effect level in dogs was 0.07 mmol/kg/d. MT218 exhibited no genotoxicity, hemolysis, and anaphylactic reactivity. CONCLUSION The preclinical assessments showed that the targeted contrast agent MT218 has high r1 and r2 relaxivities, satisfactory physicochemical properties, pharmacokinetic, and safety profiles and produces effective tumor enhancement in multiple cancer types in rats and mice at reduced doses.
Collapse
|
91
|
Lohrke J, Berger M, Frenzel T, Hilger CS, Jost G, Panknin O, Bauser M, Ebert W, Pietsch H. Preclinical Profile of Gadoquatrane: A Novel Tetrameric, Macrocyclic High Relaxivity Gadolinium-Based Contrast Agent. Invest Radiol 2022; 57:629-638. [PMID: 35703267 PMCID: PMC9444293 DOI: 10.1097/rli.0000000000000889] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Accepted: 04/12/2022] [Indexed: 11/26/2022]
Abstract
OBJECTIVES The aim of this report was to characterize the key physicochemical, pharmacokinetic (PK), and magnetic resonance imaging (MRI) properties of gadoquatrane (BAY 1747846), a newly designed tetrameric, macrocyclic, extracellular gadolinium-based contrast agent (GBCA) with high relaxivity and stability. MATERIALS AND METHODS The r1-relaxivities of the tetrameric gadoquatrane at 1.41 and 3.0 T were determined in human plasma and the nuclear magnetic relaxation dispersion profiles in water and plasma. The complex stability was analyzed in human serum over 21 days at pH 7.4 at 37°C and was compared with the linear GBCA gadodiamide and the macrocyclic GBCA (mGBCA) gadobutrol. In addition, zinc transmetallation assay was performed to investigate the kinetic inertness. Protein binding and the blood-to-plasma ratio were determined in vitro using rat and human plasma. The PK profile was evaluated in rats (up to 7 days postinjection). Magnetic resonance imaging properties were investigated using a glioblastoma (GS9L) rat model. RESULTS The new chemical entity gadoquatrane is a macrocyclic tetrameric Gd complex with one inner sphere water molecule per Gd ( q = 1). Gadoquatrane showed high solubility in buffer (1.43 mol Gd/L, 10 mM Tris-HCl, pH 7.4), high hydrophilicity (logP -4.32 in 1-butanol/water), and negligible protein binding. The r1-relaxivity of gadoquatrane in human plasma per Gd of 11.8 mM -1 ·s -1 (corresponding to 47.2 mM -1 ·s -1 per molecule at 1.41 T at 37°C, pH 7.4) was more than 2-fold (8-fold per molecule) higher compared with established mGBCAs. Nuclear magnetic relaxation dispersion profiles confirmed the more than 2-fold higher r1-relaxivity in human plasma for the clinically relevant magnetic field strengths from 0.47 to 3.0 T. The complex stability of gadoquatrane at physiological conditions was very high. The observed Gd release after 21 days at 37°C in human serum was below the lower limit of quantification. Gadoquatrane showed no Gd 3+ release in the presence of zinc in the transmetallation assay. The PK profile (plasma elimination, biodistribution, recovery) was comparable to that of gadobutrol. In MRI, the quantitative evaluation of the tumor-to-brain contrast in the rat glioblastoma model showed significantly improved contrast enhancement using gadoquatrane compared with gadobutrol at the same Gd dose administered (0.1 mmol Gd/kg body weight). In comparison to gadoterate meglumine, similar contrast enhancement was reached with gadoquatrane with 75% less Gd dose. In terms of the molecule dose, this was reduced by 90% when compared with gadoterate meglumine. Because of its tetrameric structure and hence lower number of molecules per volume, all prepared formulations of gadoquatrane were iso-osmolar to blood. CONCLUSIONS The tetrameric gadoquatrane is a novel, highly effective mGBCA for use in MRI. Gadoquatrane provides favorable physicochemical properties (high relaxivity and stability, negligible protein binding) while showing essentially the same PK profile (fast extracellular distribution, fast elimination via the kidneys in an unchanged form) to established mGBCAs on the market. Overall, gadoquatrane is an excellent candidate for further clinical development.
Collapse
|
92
|
Pothayee N, Sail D, Dodd S, Swenson RE, Koretsky AP. Multivalent Gd-DOTA Decorated Oligopeptide as Sensitive MRI Molecular Probes for In Vivo Imaging of Brain Connectivity. ACS Chem Neurosci 2022; 13:2674-2680. [PMID: 36040317 DOI: 10.1021/acschemneuro.2c00236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Abstract
One of the most important goals of brain imaging is to define the anatomical connections within the brain. In addition to revealing normal circuitry, studies of neural connections and neuronal transport can show rewiring and degeneration following brain injury and diseases. In this work, a highly sensitive magnetic resonance imaging (MRI)-visible neural tracer that can be used to visualize brain connectivity in vivo is developed. It is based on an oligopeptide with gadolinium chelates appended to the peptide backbone. This peptide construct is a sensitive MRI contrast agent that was conjugated to the classical neurotracer, Cholera-toxin Subunit-B. Injection of this probe enabled it to be used to trace neural connections in vivo. This complements other MRI tracing techniques such as diffusion tensor imaging and manganese-enhanced MRI for neural tracing.
Collapse
|
93
|
Zhang A, Wang D, Diwan S, Lin CP, Calodney A, Rosenthal R, Chang Chien GC. Effects of local anesthetics and contrast agents on musculoskeletal regenerative medicine procedures. Regen Med 2022; 17:845-853. [PMID: 36069006 DOI: 10.2217/rme-2021-0176] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
In regenerative medicine, cells, tissues and organs are often replaced, engineered or regrown in order to restore their function after they have been damaged or lost. Local anesthetics, corticosteroids and contrast agents are commonly employed for both diagnostic and therapeutic objectives in interventional pain and musculoskeletal treatments for regenerative medicine. There is growing evidence that routine injectables promote catabolism and disease processes. Thus, understanding the effects of these compounds on regenerative medicine injectates and target tissues such as tenocytes, chondrocytes, nucleus pulposus and ligamentous tissue is critical. This review includes the current research on the effects of local anesthetics and contrast agents, as well as their use and recommendations in regenerative medicine operations.
Collapse
|
94
|
Gonzalez EA, Lediju Bell MA. Dual-wavelength photoacoustic atlas method to estimate fractional methylene blue and hemoglobin contents. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:JBO-220093GR. [PMID: 36050818 PMCID: PMC9433893 DOI: 10.1117/1.jbo.27.9.096002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Accepted: 08/03/2022] [Indexed: 06/15/2023]
Abstract
SIGNIFICANCE Methylene blue (MB) is an exogenous contrast agent that has the potential to assist with visualization and penetration challenges in photoacoustic imaging. However, monitoring the local concentration between MB and endogenous chromophores is critical for avoiding unnecessary MB accumulations that could lead to adverse effects such as hemolysis when exposed to increased dose and photodamage when exposed to high laser energies. AIM We developed a modified version of a previously proposed acoustic-based atlas method to estimate concentration levels from a mixture of two photoacoustic-sensitive materials after two laser wavelength emissions. APPROACH Photoacoustic data were acquired from mixtures of 100-μM MB and either human or porcine blood (Hb) injected in a plastisol phantom, using laser wavelengths of 710 and 870 nm. An algorithm to perform linear regression of the acoustic frequency response from an atlas composed of pure concentrations was designed to assess the concentration levels from photoacoustic samples obtained from 11 known MB/Hb volume mixtures. The mean absolute error (MAE), coefficient of determination (i.e., R2), and Spearman's correlation coefficient (i.e., ρ) between the estimated results and ground-truth labels were calculated to assess the algorithm performance, linearity, and monotonicity, respectively. RESULTS The overall MAE, R2, and ρ were 12.68%, 0.80, and 0.89, respectively, for the human Hb dataset and 9.92%, 0.86, and 0.93, respectively, for the porcine Hb dataset. In addition, a similarly linear relationship was observed between the acoustic frequency response at 2.3 MHz and 870-nm laser wavelength and the ground-truth concentrations, with R2 and | ρ | values of 0.76 and 0.88, respectively. CONCLUSIONS Contrast agent concentration monitoring is feasible with the proposed approach. The potential for minimal data acquisition times with only two wavelength emissions is advantageous toward real-time implementation in the operating room.
Collapse
|
95
|
Jianxiong W, Yu W, Juyi W, Guangxia W. Intravenous combined with intrabiliary contrast-enhanced ultrasound in the evaluation of resectability of hilar cholangiocarcinomas. JOURNAL OF CLINICAL ULTRASOUND : JCU 2022; 50:931-939. [PMID: 35808898 DOI: 10.1002/jcu.23268] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 05/30/2022] [Accepted: 06/09/2022] [Indexed: 06/15/2023]
Abstract
OBJECTIVE To investigate the application value of combined intravenous contrast-enhanced ultrasound (IV-CEUS) with intrabiliary contrast-enhanced ultrasound (IB-CEUS) in the preoperative evaluation of hilar cholangiocarcinoma (HCCA) resectability. METHODS Clinical data from 82 patients with HCCA confirmed by surgery and pathology were retrospectively analyzed. Preoperative IV-CEUS + IB-CEUS and magnetic resonance cholangiopancreatography (MRCP) were performed and the results were compared with surgical and pathological findings. RESULTS The accuracy of the Bismuth-Corlette classification confirmed by IV-CEUS + IB-CEUS and MRCP was 95.12% (78/82) and 87.8% (72/82), respectively. The diagnostic precision of IV-CEUS + IB-CEUS was better than MRCP (p = 0.001). The sensitivity, specificity, and precision of CEUS for diagnosing lymph node metastases (72.7%, 93.3%, and 87.8%), intrahepatic metastases (78.6%, 98.5%, and 93.9%), invasion of the hepatic artery (92.9%, 98.5%, and 97.6%) and invasion of the portal vein (93.8%, 98.5%, and 97.6%) of HCCA were, respectively. The consistency between the preoperative evaluation of resectability confirmed by IV-CEUS +IB-CEUS and MRCP was 85.4% (70/82) and 78.0% (64/82), respectively. In addition, the evaluations did not have statistically significant differences (p > 0.05). There were no significant differences between the two evaluations (p = 0.266). CONCLUSION IV-CEUS combined with IB-CEUS has significant value in classifying HCCA and evaluating the resectability of lymph node metastases, liver metastases, and vessel invasion.
Collapse
|
96
|
Eslami P, Seo JH, Rahsepar AA, Shafique A, Rollison SF, Lardo AC, Mittal R, Chen MY. A Noninvasive Assessment of Flow Based on Contrast Dispersion in Computed Tomography Angiography: A Computational and Experimental Phantom Study. J Biomech Eng 2022; 144:091009. [PMID: 35237785 PMCID: PMC8990739 DOI: 10.1115/1.4053997] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2020] [Revised: 12/27/2021] [Indexed: 11/08/2022]
Abstract
Transluminal attenuation gradient (TAG), defined as the gradient of the contrast agent attenuation drop along the vessel, is an imaging biomarker that indicates stenosis in the coronary arteries. The transluminal attenuation flow encoding (TAFE) equation is a theoretical platform that quantifies blood flow in each coronary artery based on computed tomography angiography (CTA) imaging. This formulation couples TAG (i.e., contrast dispersion along the vessel) with fluid dynamics. However, this theoretical concept has never been validated experimentally. The aim of this proof-of-principle phantom study is to validate TAFE based on CTA imaging. Dynamic CTA images were acquired every 0.5 s. The average TAFE estimated flow rates were compared against four predefined pump values in a straight (20, 25, 30, 35, and 40 ml/min) and a tapered phantom (25, 35, 45, and 55 ml/min). Using the TAFE formulation with no correction, the flow rates were underestimated by 33% and 81% in the straight and tapered phantoms, respectively. The TAFE formulation was corrected for imaging artifacts focusing on partial volume averaging and radial variation of contrast enhancement. After corrections, the flow rates estimated in the straight and tapered phantoms had an excellent Pearson correlation of r = 0.99 and 0.87 (p < 0.001), respectively, with only a 0.6%±0.2 mL/min difference in estimation of the flow rate. In this proof-of-concept phantom study, we corrected the TAFE formulation and showed a good agreement with the actual pump values. Future clinical validations are needed for feasibility of TAFE in clinical use.
Collapse
|
97
|
Si G, Hapuarachchige S, Artemov D. Ultrasmall Superparamagnetic Iron Oxide Nanoparticles as Nanocarriers for Magnetic Resonance Imaging: Development and In Vivo Characterization. ACS APPLIED NANO MATERIALS 2022; 5:9625-9632. [PMID: 37139481 PMCID: PMC10153628 DOI: 10.1021/acsanm.2c01835] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Ultrasmall superparamagnetic iron oxide nanoparticles (uSPIOs) are attractive platforms for the development of smart contrast agents for magnetic resonance imaging (MRI). Oleic acid-capped uSPIOs are commercially available yet hydrophobic, hindering in vivo applications. A hydrophilic ligand with high affinity toward uSPIO surfaces can render uSPIOs water-soluble, biocompatible, and highly stable under physiological conditions. A small overall hydrodynamic diameter ensures optimal pharmacokinetics, tumor delivery profiles, and, of particular interest, enhanced T 1 MR contrasts. In this study, for the first time, we synthesized a ligand that not only fulfills the as-proposed properties but also provides multiple reactive groups for further modifications. The synthesis delivers a facile approach using commercially available reactants, with resultant uSPIO-ligand constructs assembled through a single-step ligand exchange process. Structural and molecular size analyses confirmed size uniformity and small hydrodynamic diameter of the constructs. On average, 43 reactive amine groups were present per uSPIO nanoparticle. Its r 1 relaxivity has been tested on a 7 Tesla MR instrument and is comparable to that of the clinically available T 1 gadolinium-based contrast agent GBCA (1 vs 3 mM-1 s-1, respectively). A significant decrease in tumor T1 (15%) within 1 h of injection and complete signal recovery after 2 h were detected with a dose of 7 μg Fe/g mouse. The agent also has high r 2 relaxivity and can be used for T 2 contrast-enhanced MRI. Taken together, good relaxation and delivery properties and the presence of multiple surface reactive groups can facilitate its application as a universal MRI-compatible nanocarrier platform.
Collapse
|
98
|
Barré R, Mouchel Dit Leguerrier D, Ruet Q, Fedele L, Imbert D, Martel-Frachet V, Fries PH, Molloy JK, Thomas F. Lanthanide complexes (GdIII and EuIII) based on a DOTA-TEMPO platform for redox monitoring via relaxivity. Chem Asian J 2022; 17:e202200544. [PMID: 35796463 PMCID: PMC9544908 DOI: 10.1002/asia.202200544] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2022] [Revised: 07/06/2022] [Indexed: 11/27/2022]
Abstract
Three lanthanide complexes (Ln=Gd, Eu) based on a DO3 A ([Ln(L1)]) or DO2 A ([Ln(L2–3)]+) platform appended by a redox active TEMPO‐based arm were prepared. Complex [Ln(L2)]+ shows an alkyne arm, offering the possibility of postfunctionalization by click reaction to yield [Ln(L3)]+. The complexes demonstrate a redox response whereby the hydroxylamine, nitroxide and oxoammonium forms of the arm can be obtained in turn. Luminescence measurements on the europium complexes support an octadentate (L1, L3) or heptadentate (L2) chelation by the ligand, with one water molecule in the inner coordination sphere. The relaxivity was determined from 20 kHz to 30 MHz by fast‐field cycling NMR. The three GdIII complexes under their hydroxylamine form [Gd(L1)] and [Gd(L2–3)]+ show r1 values of 7.0, 5.1 and 5.0 mM−1 s−1 (30 KHz), which increase to 8.8, 5.5 and 6.1 mM−1 s−1 in the nitroxide form. The radical complexes are not toxic against M21 cell lines, at least up to 40 μM. By using EPR spectroscopy we establish that they do not penetrate the cells with the exception of [Eu(L2)]+.
Collapse
|
99
|
Zheng W, Liu C, Jin J, Sun W, Zhao J, Zhao M, Yao S, Zhu B, Chen F, Shang J, Wang K, Guo P, Qin J, Cheng X. Biodegradable iron oxide nanoparticles for intraoperative parathyroid gland imaging in thyroidectomy. PNAS NEXUS 2022; 1:pgac087. [PMID: 36741464 PMCID: PMC9896913 DOI: 10.1093/pnasnexus/pgac087] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Accepted: 06/08/2022] [Indexed: 02/07/2023]
Abstract
Parathyroid gland (PG) injury is the most common complication of thyroidectomy owing to the lack of approaches for surgeons to effectively distinguish PGs from surrounding thyroid glands (TGs) in the operation room. Herein, we report the development of biodegradable iron oxide nanoparticles (IONPs) as a promising contrast agent candidate for intraoperative PG visualization. We elucidated that locally administrated dark-colored IONPs readily diffuse in TGs but cannot infiltrate tissue-dense PGs, yielding a distinguishable contrast enhancement between PGs and TGs by naked eye observation. We performed unbiased and quantitative in vivo screenings to optimize particle size and concentration of IONPs for PG/TG contrast enhancement. Moreover, in vivo applications of IONPs via the local administration route demonstrate no adverse toxicities and can be biodegraded in the thyroid microenvironment within 3 months. To our knowledge, these promising findings provide the first in vivo evidence that IONPs can serve as a safe, biodegradable, and effective contrast agent candidate for improving PG visualization in thyroidectomy.
Collapse
|
100
|
Das AB, Tranos JA, Zhang J, Wadghiri YZ, Kim SG. Estimation of Contrast Agent Concentration in DCE-MRI Using 2 Flip Angles. Invest Radiol 2022; 57:343-351. [PMID: 35025833 PMCID: PMC8986601 DOI: 10.1097/rli.0000000000000845] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
PURPOSE The aim of this study was to investigate the feasibility of using 2 flip angles (FAs) with an ultrashort echo time during dynamic contrast-enhanced (DCE)-magnetic resonance imaging (MRI) for estimation of plasma gadolinium (Gd) concentration without using a precontrast longitudinal relaxation time T1 (T10) measurement. METHODS T1-weighted DCE-MRI experiments were carried out with C57BL/6J mice using the scan protocol with 2 FAs over 3 sequential segments during 1 scan. The data with 2 FAs were used to estimate T10 (T1T) during conversion of a time-intensity curve to the time-concentration curve. Three dosages of gadolinium-based contrast agent were used to achieve a wide range of variability in Gd concentrations when measured at 10 minutes postinjection: 0.05 mmol/kg (n = 6), 0.1 mmol/kg (n = 11), and 0.15 mmol/kg (n = 7). For comparison, the signal-to-concentration conversion was also conducted using the T10 measured from the precontrast scan (T1M) as well as a constant T10 (2.1 seconds) from the literature (T1C). The Gd concentrations ([Gd]) estimated using DCE-MRI data for the time of retro-orbital blood collection ([Gd]T1T, [Gd]T1M, and [Gd]T1C, respectively) were compared against the [Gd] of the blood samples measured by inductively coupled plasma mass spectrometry ([Gd]MS). In addition, contrast kinetic model analysis was conducted on mice with GL261 brain tumors (n = 5) using the 3 different methods for T10. RESULTS T1T strongly correlated with T1M (r = 0.81). [Gd]T1M and [Gd]T1T were significantly different from [Gd]T1C. [Gd]T1M and [Gd]T1T were in good agreement with [Gd]MS with strong correlations (mean percentage error ± standard deviation) of r = 0.70 (16% ± 56%) and r = 0.85 (15% ± 44%), respectively. In contrast, [Gd]T1C had a weak correlation of r = 0.52 with larger errors of 33% ± 24%. The contrast kinetic model parameters of GL261 brain tumors using T1T were not significantly different from those using T1M. CONCLUSIONS This study substantiates the feasibility of using the 2-FA approach during DCE-MRI scan to estimate [Gd] in the plasma without using an extra scan to perform precontrast T1 measurements.
Collapse
|