101
|
Woo S, Lee JM, Yoon JH, Joo I, Kim SH, Lee JY, Yoon JH, Kim YJ, Han JK, Choi BI. Small- and medium-sized hepatocellular carcinomas: monopolar radiofrequency ablation with a multiple-electrode switching system-mid-term results. Radiology 2013; 268:589-600. [PMID: 23513241 DOI: 10.1148/radiol.13121736] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
PURPOSE To prospectively assess the safety and mid-term therapeutic effectiveness of monopolar radiofrequency (RF) ablation with a multiple-electrode switching system for treating small- and medium-sized (≤ 5 cm) hepatocellular carcinomas (HCCs). MATERIALS AND METHODS The institutional review board approved this prospective study, and all patients gave informed consent. From February 2009 to January 2010, 166 patients (110 men and 56 women; age range, 38-86 years; mean age, 62 years ± 10 [standard deviation]) with 166 HCCs less than or equal to 5 cm in diameter were treated with monopolar RF ablation with a multiple-electrode switching system. One of three experienced radiologists performed the RF ablation. Technique effectiveness, ablation volume and time, and major complications were evaluated by means of computed tomography (CT) immediately after RF ablation and at follow-up CT examinations at 1 month and then every 3 months after the procedure. The overall survival, disease-free survival, and local tumor progression-free survival rates were evaluated by using the Kaplan-Meier method. RESULTS The technique effectiveness rate determined 1 month after RF ablation was 99.4%. Mean ablation parameters were as follows: volume, 85 cm(3) ± 54; maximum diameter, 61 mm ± 13; and minimum diameter, 43 mm ± 11. The major complication rate was 4.8%. The 6-month and 1-, 2-, and 3-year local tumor progression rates were 2%, 6%, 10%, and 11%, respectively. The overall survival rates at 1, 2, and 3 years after RF ablation were 99%, 97%, and 96%, and corresponding local tumor progression-free survival rates were 94%, 90%, and 89%, respectively. The disease-free survival rates at 1, 2, and 3 years after RF ablation were 75%, 60%, and 54%, respectively. CONCLUSION Monopolar RF ablation with a multiple-electrode switching system in small- and medium-sized HCCs was safe and efficient, and it provided successful local tumor control and high local tumor progression-free survival rates because an adequate ablation volume was obtained.
Collapse
|
102
|
Yoon JH, Lee JM, Woo HS, Yu MH, Joo I, Lee ES, Sohn JY, Lee KB, Han JK, Choi BI. Staging of hepatic fibrosis: comparison of magnetic resonance elastography and shear wave elastography in the same individuals. Korean J Radiol 2013; 14:202-12. [PMID: 23483022 PMCID: PMC3590331 DOI: 10.3348/kjr.2013.14.2.202] [Citation(s) in RCA: 58] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2012] [Accepted: 10/12/2012] [Indexed: 02/06/2023] Open
Abstract
Objective To cross-validate liver stiffness (LS) measured on shear wave elastography (SWE) and on magnetic resonance elastography (MRE) in the same individuals. Materials and Methods We included 94 liver transplantation (LT) recipients and 114 liver donors who underwent either MRE or SWE before surgery or biopsy. We determined the technical success rates and the incidence of unreliable LS measurements (LSM) of SWE and MRE. Among the 69 patients who underwent both MRE and SWE, the median and coefficient of variation (CV) of the LSM from each examination were compared and correlated. Areas under the receiver operating characteristic curve in both examinations were calculated in order to exclude the presence of hepatic fibrosis (HF). Results The technical success rates of MRE and SWE were 96.4% and 92.2%, respectively (p = 0.17), and all of the technical failures occurred in LT recipients. SWE showed 13.1% unreliable LSM, whereas MRE showed no such case (p < 0.05). There was moderate correlation in the LSM in both examinations (r = 0.67). SWE showed a significantly larger median LSM and CV than MRE. Both examinations showed similar diagnostic performance for excluding HF (Az; 0.989, 1.000, respectively). Conclusion MRE and SWE show moderate correlation in their LSMs, although SWE shows higher incidence of unreliable LSMs in cirrhotic liver.
Collapse
|
103
|
Lee ES, Lee JM, Kim KW, Lee IJ, Han JK, Choi BI. Evaluation of the in vivo efficiency and safety of hepatic radiofrequency ablation using a 15-G Octopus® in pig liver. Korean J Radiol 2013; 14:194-201. [PMID: 23482995 PMCID: PMC3590330 DOI: 10.3348/kjr.2013.14.2.194] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2012] [Accepted: 09/17/2012] [Indexed: 12/14/2022] Open
Abstract
OBJECTIVE To determine in vivo efficacy of radiofrequency ablation (RFA) in porcine liver by using 15-gauge Octopus® (15-G Octopus®) electrodes to create a large coagulation. MATERIALS AND METHODS A total of 18 coagulations were created by using a 180-W generator and 15-G Octopus® electrodes during laparotomy, performed in 14 pigs. Coagulation necrosis was created in the pig livers by the use of one of three RFA protocols: 1) group A, monopolar RFA using a 15-G Octopus® electrode with a 5-mm inter-electrode distance (n = 4); 2) group B, monopolar RFA using a 15-G Octopus® electrode with a 10-mm inter-electrode distance (n = 6); and 3) group C, switching monopolar RFA using two 15-G Octopus® electrodes (n = 8). The energy efficiency, shape, maximum and minimum diameters (Dmx and Dmi), and the volume of the coagulation volume were measured in each group. The Summary statistics were obtained and Mann-Whitney test was were performed. RESULTS The mean ablated volume of each group was 49.23 cm(3) in A, 64.11 cm(3) in B, and 72.35 cm(3) in C. The mean Dmx and Dmi values were 5.68 cm and 4.58 cm in A and 5.97 cm and 4.97 cm in B, respectively. In group C, the mean diameters of Dmx and Dmi were 6.80 cm and 5.11 cm, respectively. The mean ratios of Dmi/Dmx were 1.25, 1.20, and 1.35 in groups A, B, and C, respectively. There was one animal death during the RFA procedure, the cause of which could not be subsequently determined. However, there were no other significant, procedure-related complications during the seven-hour-delayed CT scans. CONCLUSION RFA procedures using 15-G Octopus® electrodes are useful and safe for creating a large ablation in a single electrode model as well as in the multiple electrodes model.
Collapse
|
104
|
Kang KM, Lee JM, Shin CI, Baek JH, Kim SH, Yoon JH, Han JK, Choi BI. Added value of diffusion-weighted imaging to MR cholangiopancreatography with unenhanced mr imaging for predicting malignancy or invasiveness of intraductal papillary mucinous neoplasm of the pancreas. J Magn Reson Imaging 2013; 38:555-63. [PMID: 23390008 DOI: 10.1002/jmri.24022] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2012] [Accepted: 12/07/2012] [Indexed: 02/01/2023] Open
Abstract
PURPOSE To investigate the added value of diffusion-weighted imaging (DWI) to magnetic resonance cholangiopancreatography (MRCP) with unenhanced MR imaging for predicting the malignancy or invasiveness of intraductal papillary mucinous neoplasms (IPMNs). MATERIALS AND METHODS Following Institutional Review Board (IRB) approval, this retrospective study included 52 patients with surgically resected IPMNs and who underwent MRCP, unenhanced MRI, and DWI. Three blinded radiologists evaluated the two image sets, ie, MRCP with unenhanced MR images vs. the combined set with MRCP, unenhanced MR images, and DWI, and scored their confidence for malignancy or for invasiveness of IPMNs. The mean apparent diffusion coefficient (ADC) values of benign IPMNs and of intraductal mucinous carcinomas (IPMCs) were compared. The diagnostic accuracy was calculated using receiver operating characteristic (ROC) curve analysis. RESULTS The mean ADC of malignant IPMNs (2.05 ± 0.66 × 10(-3) mm(2) /sec) was significantly lower than that of benign IPMNs (2.95 ± 0.32 × 10(-3) mm(2) /sec, P < 0.0001). Invasive IPMCs (1.51 ± 0.32 × 10(-3) mm(2) /sec) showed significantly lower ADC than that of noninvasive IPMCs (2.67 ± 0.23 × 10(-3) mm(2) /sec, P = 0.0003). The area of diffusion restriction was more frequently seen in malignant IPMNs than in benign IPMNs (P < 0.00001). The addition of DWI to MRCP with unenhanced MRI did not show a significant improvement for predicting malignant IPMN (P> 0.05), but resulted in a tendency to improve the diagnostic accuracy for the prediction of invasive IPMN in two observers (P = 0.072, P = 0.085). CONCLUSION The addition of DWI to MRCP with unenhanced MRI may improve the diagnosis of malignant IPMN and further increase the prediction of invasive IPMC.
Collapse
|
105
|
Claudon M, Dietrich CF, Choi BI, Cosgrove DO, Kudo M, Nolsøe CP, Piscaglia F, Wilson SR, Barr RG, Chammas MC, Chaubal NG, Chen MH, Clevert DA, Correas JM, Ding H, Forsberg F, Fowlkes JB, Gibson RN, Goldberg BB, Lassau N, Leen ELS, Mattrey RF, Moriyasu F, Solbiati L, Weskott HP, Xu HX. Guidelines and good clinical practice recommendations for Contrast Enhanced Ultrasound (CEUS) in the liver - update 2012: A WFUMB-EFSUMB initiative in cooperation with representatives of AFSUMB, AIUM, ASUM, FLAUS and ICUS. ULTRASOUND IN MEDICINE & BIOLOGY 2013; 39:187-210. [PMID: 23137926 DOI: 10.1016/j.ultrasmedbio.2012.09.002] [Citation(s) in RCA: 479] [Impact Index Per Article: 43.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Initially, a set of guidelines for the use of ultrasound contrast agents was published in 2004 dealing only with liver applications. A second edition of the guidelines in 2008 reflected changes in the available contrast agents and updated the guidelines for the liver, as well as implementing some non-liver applications. Time has moved on, and the need for international guidelines on the use of CEUS in the liver has become apparent. The present document describes the third iteration of recommendations for the hepatic use of contrast enhanced ultrasound (CEUS) using contrast specific imaging techniques. This joint WFUMB-EFSUMB initiative has implicated experts from major leading ultrasound societies worldwide. These liver CEUS guidelines are simultaneously published in the official journals of both organizing federations (i.e., Ultrasound in Medicine and Biology for WFUMB and Ultraschall in der Medizin/European Journal of Ultrasound for EFSUMB). These guidelines and recommendations provide general advice on the use of all currently clinically available ultrasound contrast agents (UCA). They are intended to create standard protocols for the use and administration of UCA in liver applications on an international basis and improve the management of patients worldwide.
Collapse
|
106
|
Claudon M, Dietrich CF, Choi BI, Cosgrove DO, Kudo M, Nolsøe CP, Piscaglia F, Wilson SR, Barr RG, Chammas MC, Chaubal NG, Chen MH, Clevert DA, Correas JM, Ding H, Forsberg F, Fowlkes JB, Gibson RN, Goldberg BB, Lassau N, Leen ELS, Mattrey RF, Moriyasu F, Solbiati L, Weskott HP, Xu HX. Guidelines and good clinical practice recommendations for contrast enhanced ultrasound (CEUS) in the liver--update 2012: a WFUMB-EFSUMB initiative in cooperation with representatives of AFSUMB, AIUM, ASUM, FLAUS and ICUS. ULTRASCHALL IN DER MEDIZIN (STUTTGART, GERMANY : 1980) 2013; 34:11-29. [PMID: 23129518 DOI: 10.1055/s-0032-1325499] [Citation(s) in RCA: 210] [Impact Index Per Article: 19.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Initially, a set of guidelines for the use of ultrasound contrast agents was published in 2004 dealing only with liver applications. A second edition of the guidelines in 2008 reflected changes in the available contrast agents and updated the guidelines for the liver, as well as implementing some non-liver applications. Time has moved on, and the need for international guidelines on the use of CEUS in the liver has become apparent. The present document describes the third iteration of recommendations for the hepatic use of contrast enhanced ultrasound (CEUS) using contrast specific imaging techniques. This joint WFUMB-EFSUMB initiative has implicated experts from major leading ultrasound societies worldwide. These liver CEUS guidelines are simultaneously published in the official journals of both organizing federations (i.e., Ultrasound in Medicine and Biology for WFUMB and Ultraschall in der Medizin/European Journal of Ultrasound for EFSUMB). These guidelines and recommendations provide general advice on the use of all currently clinically available ultrasound contrast agents (UCA). They are intended to create standard protocols for the use and administration of UCA in liver applications on an international basis and improve the management of patients worldwide.
Collapse
|
107
|
Kim KW, Lee JM, Jeon YS, Lee IJ, Choi Y, Park J, Kiefer B, Kim C, Han JK, Choi BI. Vascular disrupting effect of CKD-516: preclinical study using DCE-MRI. Invest New Drugs 2013; 31:1097-106. [PMID: 23299389 DOI: 10.1007/s10637-012-9915-6] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2012] [Accepted: 12/11/2012] [Indexed: 11/29/2022]
Abstract
Vascular disrupting agents (VDAs) are new class of anti-cancer drugs targeting pre-existing tumor vasculature which lead to tumor ischemia and necrosis. An innovative tubulin polymerization inhibitor, CKD-516, was recently developed as a VDA. We attempted to evaluate its tubulin destabilizing effect using immunofluorescence staining on human endothelial cells (HUVECs) and to ascertain its antivascular effect in a rabbit VX2 tumor model using dynamic contrast-enhanced (DCE) MRI by measuring the changes in kinetic parameters such as K-trans and IAUGC. Immunofluorescence staining using anti-tubulin and anti-actin antibodies on HUVECs showed that CKD-516 selectively disrupted tubulin component of the endothelial cytoskeleton. Serial DCE-MRI showed a significant decrease in K-trans and IAUGC parameters from baseline at 4 h (39.9 % in K-trans; -45.0 % in IAUGC) and at 24 h (-32.2 % in K-trans; -36.5 % in IAUGC), and a significant recovery at 48 h (22.9 % in K-trans; 34.8 % in IAUGC) following administration of CKD-516 at a 0.7-mg/kg dose. When the tumors were stratified according to the initial K-trans value of 0.1, tumors with a high K-trans > 0.1 which was indicative of having well-developed pre-existing vessels, showed greater reduction in K-trans and IAUGC values. On histologic examination, the degree of necrosis of treated tumors was significantly greater than that of untreated tumors. In summary, CKD-516 is an effective VDA which results in rapid vascular shutdown by targeting the tubulin component of tumor vessels and thus leads to necrosis.
Collapse
|
108
|
Kim JH, Eun HW, Hong SS, Kim YJ, Han JK, Choi BI. Gastric cancer detection using MDCT compared with 2D axial CT: diagnostic accuracy of three different reconstruction techniques. ACTA ACUST UNITED AC 2013; 37:541-8. [PMID: 22080389 DOI: 10.1007/s00261-011-9823-9] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
PURPOSE To assess the diagnostic accuracy of different reconstruction techniques using MDCT for gastric cancer detection compared with 2D axial CT. MATERIALS AND METHODS During 7 months, we performed CT examinations of 104 consecutive patients with gastric cancer and of a control group composed of 35 patients without gastric disease. All gastric cancer was pathologically proven by endoscopy and surgery. Among 104 patients with gastric cancer, 63 patients had early gastric cancer (EGC). Two radiologists retrospectively and independently interpreted the axial CT and three different reconstruction techniques including multiplanar reformation (MPR), transparent imaging (TI), and virtual gastroscopy (VG), using a commercially available, 3D workstation. They graded the presence or absence of gastric cancer in each image sets using a five-point scale and, if present, they assessed its location. Diagnostic accuracy was compared using the area under the receiver operating characteristic curve (Az) for both gastric cancer and only EGC. Sensitivity and specificity were also calculated for each image technique. The k statistics were used to determine inter-observer agreement. RESULTS The diagnostic accuracy for overall gastric cancer detection for each of the image sets was as follows: 2D axial CT (Az = 0.858); MPR (Az = 0.879); TI (Az = 0.873); and VG (Az = 0.928). VG had significantly better performance than 2D axial CT (p = 0.016). The sensitivity and specificity were as follows: 76.7% and 82.9% in axial CT; 79.6% and 85.7% in MPR; 91.3% and 80% in TI; and 95.1% and 74.3% in VG. In EGC, the diagnostic performance for its detection was as follows: axial CT (Az = 0.777); MPR (Az = 0.811); TI (Az = 0.825); and VG (Az = 0.896). VG had significantly better performance than both 2D axial CT (P = 0.006) and MRP (P = 0.038). The sensitivity and specificity were as follows: 62.9% and 82.9% in axial CT; 67.7% and 85.7% in MPR; 85.5% and 80% in TI; and 91.9% and 74.3% in VG. The inter-observer agreement showed substantial agreement (κ = 0.67-0.75). CONCLUSION Among the different reconstruction techniques, VG accurately detects gastric cancer and is especially useful for EGC compared with 2D axial CT.
Collapse
|
109
|
Lee DH, Lee JM, Klotz E, Kim SJ, Kim KW, Han JK, Choi BI. Detection of recurrent hepatocellular carcinoma in cirrhotic liver after transcatheter arterial chemoembolization: value of quantitative color mapping of the arterial enhancement fraction of the liver. Korean J Radiol 2012; 14:51-60. [PMID: 23323031 PMCID: PMC3542303 DOI: 10.3348/kjr.2013.14.1.51] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2012] [Accepted: 07/11/2012] [Indexed: 11/24/2022] Open
Abstract
Objective To investigate the additional diagnostic value of color mapping of the hepatic arterial enhancement fraction (AEF) for detecting recurrent or residual hepatocellular carcinoma (HCC) in patients treated with transcatheter arterial chemoembolization (TACE). Materials and Methods Seventy-six patients with 126 HCCs, all of whom had undergone previous TACE, and subsequently, underwent follow-up multiphasic liver CT scans, were included in this study. Quantitative color maps of the AEF of the whole liver were created, by using prototype software with non-rigid registration. The AEF was defined as the ratio of the attenuation increment during the arterial phase to the attenuation increment during the portal phase. Two radiologists independently analyzed the two image sets at a two-week interval, i.e., the multiphasic CT image set and the second image set of the AEF color maps and the CT images. The additional diagnostic value of the AEF color mapping was determined, by the use of the jackknife-alternative free-response receiver-operating-characteristic analysis. The sensitivity and positive predictive values for detecting HCCs of each image set were also evaluated and compared. Results The reader-averaged figures of merit were 0.699 on the initial interpretation of the MDCT image set, and 0.831 on the second interpretation of the combined image set; the difference between the two interpretations was significant (p value < 0.001). The mean sensitivity for residual or recurrent HCC detection increased from 62.7% on the initial analysis to 82.1% on the second analysis using the AEF color maps (p value < 0.001). The mean positive predictive value for HCC detection was 74.5% on the initial analysis using MDCT, and 71.6% on the second analysis using AEF color mapping. Conclusion Quantitative color mapping of the hepatic AEF may have the possibility to increase the diagnostic performance of MDCT for the detection of recurrent or residual HCC without the potential risk of radiation-related hazards.
Collapse
|
110
|
Lee DH, Lee JM, Han JK, Choi BI. MR elastography of healthy liver parenchyma: Normal value and reliability of the liver stiffness value measurement. J Magn Reson Imaging 2012; 38:1215-23. [PMID: 23281116 DOI: 10.1002/jmri.23958] [Citation(s) in RCA: 75] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2012] [Accepted: 10/16/2012] [Indexed: 12/19/2022] Open
Abstract
PURPOSE To investigate the normal liver stiffness value using MR elastography (MRE) and to compare the repeatability and reproducibility of three measurement methods. MATERIALS AND METHODS Forty-nine subjects who underwent liver MR imaging including elastography using a 1.5 Tesla scanner, who had normal laboratory test results, and who underwent liver donation, were included in this study. Two, independent readers measured the liver stiffness value of the hepatic parenchyma using three methods, including evaluating various liver parenchyma portions using different-sized, regions-of-interest (ROIs): 2cm-ROI-per-slice in the right lobe (2cm-per-slice); 1cm-ROI-per-segment (1cm-S); and 70%-of-the-surface area (70% S). The mean liver stiffness values were compared between gender using the t-test and among the age groups using one-way analysis of variance. The reproducibility and repeatability of the three liver stiffness value measurement methods were determined using intraclass correlation coefficients (ICCs) and the 95% Bland-Altman limits of agreement. RESULTS The liver stiffness values in living liver donors ranged from 1.54 to 2.87 kPa. The mean stiffness value was 2.05 kilopascal using the 2cm-per-slice method, 2.01 kilopascal with the 1cm-S method and 2.12 kilopascal using the 70% S method. There was no significant difference in the liver stiffness value according to the gender or age factors. For reproducibility, the ICCs were 0.416 with the 2cm-per-slice method, 0.800 using the 1cm-S method, and 0.845 with the 70% S method. In terms of repeatability, the ICCs were 0.238 using the 2cm-per-slice method, 0.914 with the 1cm-S method, and 0.852 using the 70% S method. The ICCs determined using the 2cm-per-slice method were significantly lower than those of the 1cm-S or 70% S method for assessing both reproducibility and repeatability. The 95% limit of agreement was 54.0% with the 2cm-per-slice method, 24.0% using the 1cm-S method, and 18.8% with the 70% S method, in terms of reproducibility. To assess the repeatability, the 95% limit of agreement was 63.3% using the 2cm-per-slice method, 20.6% with the 1cm-S method, and 17.4% using the 70% S method. CONCLUSION The mean liver stiffness values in living donors ranged from 2.05 to 2.12 kilopascals and did not differ significantly for either gender or age. The 1cm-S and 70% S methods were significantly more reliable compared with the 2cm-per-slice method.
Collapse
|
111
|
Sun HY, Lee JM, Park HS, Yoon JH, Baek JH, Han JK, Choi BI. Gadoxetic acid-enhanced MRI with MR cholangiography for the preoperative evaluation of bile duct cancer. J Magn Reson Imaging 2012; 38:138-47. [PMID: 23281093 DOI: 10.1002/jmri.23957] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2011] [Accepted: 10/16/2012] [Indexed: 12/13/2022] Open
Abstract
PURPOSE To assess the diagnostic accuracy of gadoxetic acid-enhanced biliary MRI with MR cholangiography (MRC) in the preoperative evaluation of bile duct cancer (BDC) staging and resectability. MATERIALS AND METHODS Seventy-three patients with BDC who underwent gadoxetic acid-enhanced biliary MRI and MRC, were included in this study. Two abdominal radiologists evaluated the biliary MRI findings regarding the tumor extent, vascular involvement, lymph node metastasis, and tumor resectability. The results were compared with the surgical and pathology findings which were used as the standard reference. The diagnostic performance of the MRI was evaluated using receiver operating characteristics (ROC) analysis. In addition, to determine whether the hepatobiliary phase images had been successfully obtained, the enhancement percentage of the hepatic parenchyma was measured on the portal venous images (PVI) and hepatobiliary phase images (HBPI), respectively. RESULTS The overall accuracy of the two reviewers for determining the tumor resectability was 61.6% and 83.5%, respectively. The Az values were 0.802 for reviewer 1 and 0.892 for reviewer 2 in the evaluation of the secondary biliary confluence tumor involvement and 0.773 for reviewer 1 and 0.846 for reviewer 2 in the evaluation of the intrapancreatic bile duct involvement. In the evaluation of the vascular involvement, the Az values were 0.718 and 0.906, respectively, for the hepatic artery evaluation and 0.55 and 0.88, respectively, for the portal vein evaluation. For assessment of lymph node metastasis, the overall accuracy was 69.6% and 79.7%, respectively. The mean enhancement percentages of hepatic parenchyma on PVI and HBPI were 39.3% and 65.9%, respectively (P % 0.05), and 49 of 73 patients (67.1%) showed higher enhancement percentage on HBPI than on PVI CONCLUSION: Gadoxetic acid-enhanced MRI with MRC is a reliable diagnostic method for assessing the tumor extent and resectability of BDC.
Collapse
|
112
|
Kim SJ, Lee JM, Kim H, Yoon JH, Han JK, Choi BI. Role of diffusion-weighted magnetic resonance imaging in the diagnosis of gallbladder cancer. J Magn Reson Imaging 2012; 38:127-37. [PMID: 23281048 DOI: 10.1002/jmri.23956] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2012] [Accepted: 10/10/2012] [Indexed: 12/13/2022] Open
Abstract
PURPOSE To determine the additional diagnostic value of high b-value diffusion-weighted imaging (DWI) compared to conventional biliary magnetic resonance imaging (MRI) for differentiating gallbladder (GB) cancer from benign GB diseases with wall thickening. MATERIALS AND METHODS Thirty-nine patients with GB cancers and 36 patients with cholecystitis having preoperative biliary MRIs were included. All patients underwent unenhanced T1- and T2-weighted imaging (T2WI), Gd-enhanced dynamic MRI, and DWI (b values 0, 100, 500, 1000 s/mm(2) ). Two radiologists independently analyzed two sets of MRI for characterization of GB lesions: a conventional biliary image (CBI) set with T1- and T2WI and a dynamic image; and a DWI set composed of DWI and a CBI set. Diagnostic accuracy and sensitivity were evaluated using the receiver operator characteristic method. The mean apparent diffusion coefficient (ADC) values of the lesions were also calculated. RESULTS The Az values were 0.856 and 0.960 for reviewers 1 and 2, respectively, with the CBI set and increased to 0.952 and 0.983 with the DWI set. The mean ADC value of GB carcinoma was 1.46 ± 0.45 × 10(-3) mm(2) /s and that of cholecysititis was 2.16 ± 0.56 × 10(-3) mm(2) /s (P < 0.0001). CONCLUSION Adding DWI to the standard biliary MRI protocol may improve sensitivity for distinguishing GB cancers from benign GB diseases with wall thickening.
Collapse
|
113
|
Joo I, Lee JY, Kim JH, Kim SJ, Kim MA, Han JK, Choi BI. Differentiation of adenomyomatosis of the gallbladder from early-stage, wall-thickening-type gallbladder cancer using high-resolution ultrasound. Eur Radiol 2012; 23:730-8. [PMID: 23247807 DOI: 10.1007/s00330-012-2641-9] [Citation(s) in RCA: 56] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2012] [Revised: 07/27/2012] [Accepted: 08/01/2012] [Indexed: 12/25/2022]
Abstract
OBJECTIVES To evaluate the diagnostic performance of transabdominal high-resolution ultrasound (HRUS) for differentiation of adenomyomatosis from early-stage, wall-thickening-type gallbladder (GB) cancer. METHODS HRUS was defined as the addition of high megahertz imaging to conventional low megahertz imaging with use of state-of-the-art imaging technology. HRUS findings were retrospectively compared in 45 patients with adenomyomatosis and 28 patients with stage T1/T2 wall-thickening-type GB cancer. For evaluating HRUS performance in the differential diagnosis of adenomyomatosis from GB cancer, receiver operating characteristic curve analysis was used with a five-point confidence scale independently scored by three blinded radiologists who also analysed morphological abnormalities. RESULTS The area under the receiver operating characteristic curve (A (z)) values of HRUS in the diagnosis of adenomyomatosis were 0.948, 0.915 and 0.917 for reviewers 1, 2 and 3. Symmetrical wall thickening, intramural cystic spaces, intramural echogenic foci and twinkling artefacts were significantly associated with adenomyomatosis (P < 0.05), whereas irregular thickening of the outer wall, focal innermost hyperechoic layer (IHL) discontinuity, IHL irregularity, IHL thickening greater than 1 mm, loss of multilayer pattern in the GB wall, and intralesional vascularity were significantly associated with cancer (P < 0.05). The sensitivity, specificity and accuracy of intramural cystic spaces/echogenic foci for the diagnosis of adenomyomatosis were 80.0 %, 85.7 % and 82.2 %. CONCLUSIONS This study showed that HRUS can be helpful for distinguishing adenomyomatosis from early-stage, wall-thickening-type GB cancer.
Collapse
|
114
|
Kim KW, Lee JM, Jeon YS, Kang SE, Baek JH, Han JK, Choi BI, Bang YJ, Kiefer B, Block KT, Ji H, Bauer S, Kim C. Free-breathing dynamic contrast-enhanced MRI of the abdomen and chest using a radial gradient echo sequence with K-space weighted image contrast (KWIC). Eur Radiol 2012. [PMID: 23187728 DOI: 10.1007/s00330-012-2699-4] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
OBJECTIVES To evaluate the feasibility of free-breathing, dynamic contrast-enhanced (DCE) MRI of the abdomen and thorax using the radial-gradient-echo sequence with k-space weighted image contrast (KWIC) reconstruction. METHODS Institutional review board approval was obtained. Fourteen patients underwent free-breathing radial DCE-MRI. Radial MRI yielded full-frame images by gridding all k-space data and time-resolved subframe images by using KWIC reconstruction technique. Using subframe KWIC images, voxel-wise perfusion maps were created. For comparison, the breath-hold conventional Cartesian 3D-gradient-echo sequence (VIBE) was also performed during the equilibrium phase. The image qualities of radial and conventional VIBE images were compared quantitatively and qualitatively. RESULTS Radial DCE-MRI provided high spatial resolution (1.4 × 1.4 mm) and temporal resolution (4.1 s for subframe images) allowing voxel-wise perfusion mapping with negligible motion or streaking artefacts. There were no significant differences in SNR between full-frame radial images and conventional VIBE images (79.08 vs 74.80, P > 0.05). Overall image quality score of full-frame radial images was slightly lower than that of conventional VIBE images (3.88 ± 0.59 vs. 4.31 ± 0.97, P < 0.05), but provided clinically useful images. CONCLUSIONS The free-breathing radial DCE-MRI can provide high spatial and temporal resolution while maintaining reasonably high image quality and thus is a feasible technique for DCE-MRI in the abdomen and thorax. KEY POINTS • Dynamic contrast-enhanced magnetic resonance imaging (DCE) MRI is important in oncological imaging • Radial MRI with k-space weighted image contrast (KWIC) reconstruction offers potential improvements • Radial DCE-MRI provides good image quality, reduced artefacts and high spatial/temporal resolution.
Collapse
|
115
|
Kim JH, Lee JM, Park JH, Kim SC, Joo I, Han JK, Choi BI. Solid pancreatic lesions: characterization by using timing bolus dynamic contrast-enhanced MR imaging assessment--a preliminary study. Radiology 2012. [PMID: 23192779 DOI: 10.1148/radiol.12120111] [Citation(s) in RCA: 58] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
PURPOSE To assess the feasibility of postprocessing dynamic contrast material-enhanced (DCE) magnetic resonance (MR) imaging timing bolus data by using a three-dimensional radial gradient-echo technique with k-space-weighted image contrast (KWIC) for the characterization of solid pancreatic diseases. MATERIALS AND METHODS This retrospective study was approved by the institutional review board, and informed consent was waived. A total of 45 patients suspected of having biliary or pancreatic disease underwent pancreatic MR examination with a 3.0-T imager with a low-dose (2 mL gadopentetate dimeglumine) timing bolus by using the radial KWIC technique. There were 24 patients with pancreatic cancers, eight with pancreatic neuroendocrine tumors (PNETs), three with chronic pancreatitis, and 10 with a normal pancreas. By using a dedicated postprocessing software program for DCE MR imaging, the following perfusion parameters were measured for tumor and nontumorous parenchyma: volume transfer coefficient (K(trans)) and extracellular extravascular volume fraction; the rate constant (k(ep)) and initial area under the concentration curve in 60 seconds (iAUC) were then generated. The perfusion parameters acquired on DCE MR images were compared among the groups by using the analysis of variance test. RESULTS K(trans), k(ep), and iAUC values in patients with pancreatic cancer (0.042 min(-1) ± 0.023 [standard deviation], 0.761 min(-1) ± 0.529, and 2.841 mmol/sec ± 1.811, respectively) were significantly lower than in patients with a normal pancreas (0.387 min(-1) ± 0.176, 6.376 min(-1) ± 2.529, and 7.156 mmol/sec ± 3.414, respectively) (P < .05 for all). In addition, k(ep) values of PNETs and normal pancreas also differed (P < .0001), and K(trans), k(ep), and iAUC values of pancreatic cancers and PNETs differed significantly (P < .0001, P = .038, and P < .0001, respectively). CONCLUSION Results of timing bolus DCE MR imaging with the radial KWIC sequence from routine examinations can be postprocessed to yield potentially useful perfusion parameters for the characterization of pancreatic diseases.
Collapse
|
116
|
Chu AJ, Lee JM, Lee YJ, Moon SK, Han JK, Choi BI. Dual-source, dual-energy multidetector CT for the evaluation of pancreatic tumours. Br J Radiol 2012; 85:e891-8. [PMID: 22972978 DOI: 10.1259/bjr/26129418] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
OBJECTIVE To investigate the potential diagnostic value of dual-energy CT (DECT) with virtual non-enhanced (VNE) and iodine-only images, and to determine the optimal mixed ratio of blended images for evaluation of pancreatic diseases. METHODS Multiphasic DECT was performed in 44 patients with focal pancreatic disease. DECT was used during the pancreatic and hepatic venous phases, and a peak kilovoltage of 120 kVp was used for both non-contrast phases. For qualitative analysis of the CT images, two radiologists assessed three image sets (VNE, iodine-only and blended images) in order to determine the acceptability of VNE in replacing true non-enhanced (TNE) images, the added value of iodine-only images and the preferred blending ratio. For quantitative analyses, the CT numbers and image noise of the pancreatic parenchyma, lesions, aorta and psoas muscle were measured. The contrast-to-noise ratio of the lesion was calculated on the pancreatic phase images. The effective radiation dose for DECT and TNE images was calculated. Statistical comparisons were made using the Friedman test, the Wilcoxon test, the paired t-test and repeated measures of analysis of variation with Bonferroni correction for multiple comparisons. RESULTS The level of acceptance of the VNE images in replacing TNE images was 90.9%. Regarding the iodine-only images, 50% of the cases were found to have an added value. The linear-blended images with a weighting factor of 0.5 were preferred. CONCLUSIONS DECT was able to provide high-quality VNE images that could replace TNE images and iodine-only images showing an added value. Blended images with a weighting factor of 0.5 were preferred by the reviewers.
Collapse
|
117
|
Lee JH, Lee JM, Kim SJ, Baek JH, Yun SH, Kim KW, Han JK, Choi BI. Enhancement patterns of hepatocellular carcinomas on multiphasicmultidetector row CT: comparison with pathological differentiation. Br J Radiol 2012; 85:e573-83. [PMID: 22919011 DOI: 10.1259/bjr/86767895] [Citation(s) in RCA: 76] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
OBJECTIVE The objective of this study was to determine the incidence of typical and atypical enhancement patterns of hepatocellular carcinomas (HCCs) on multiphasic multidetector row CT (MDCT) and to correlate the enhancement patterns and morphological image findings of HCC with the degree of tumour differentiation. METHODS MDCT images of 217 patients with 243 surgically proven HCCs were evaluated through consensus reading by two radiologists. Our MDCT protocol was composed of precontrast, arterial, portal and delayed phases. The reviewers analysed the CT images for degree of attenuation; relative timing of washout; presence of dysmorphic intratumoral vessels, aneurysms and necrosis; tumour size; tumour margin; presence of pseudocapsule; intratumoral heterogeneity; and determined enhancement pattern. The imaging features were correlated with tumour differentiation using Fisher's exact test or the χ(2) test. RESULTS Among 243 HCCs, 137 (56.4%) showed the typical enhancement pattern of HCC, which is arterial enhancement and washout on portal or equilibrium phase images. In the arterial phase, 190 of 243 (78.2%) HCCs showed hypervascularity, with approximately three quarters of poorly differentiated (PD) (34 of 45, 75.6%) and moderately differentiated (MD) HCCs (92 of 123, 74.8%) showing washout during the portal or delayed phases, vs only 50% of well-differentiated (WD) HCCs (11 of 22; p<0.048). The presence of intratumoral vessels and aneurysms, tumour necrosis, attenuation of precontrast, the relative timing of washout, intratumoral attenuation heterogeneity, tumour margin and tumour size were correlated with the pathological differentiation of HCCs (p<0.05). CONCLUSION A typical enhancement of HCCs on MDCT was not unusual (43.6%) and WD and PD HCCs account for most of the atypical enhancement patterns. Early washout favoured MD and PD HCCs rather than WD HCCs, whereas in our study the presence of intratumoral aneurysm was a highly specific finding for PD HCC.
Collapse
|
118
|
Lee KH, Lee JM, Moon SK, Baek JH, Park JH, Flohr TG, Kim KW, Kim SJ, Han JK, Choi BI. Attenuation-based Automatic Tube Voltage Selection and Tube Current Modulation for Dose Reduction at Contrast-enhanced Liver CT. Radiology 2012; 265:437-447. [DOI: 10.1148/radiol.12112434] [Citation(s) in RCA: 74] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/30/2023]
|
119
|
Lee JY, Choi BI, Chung YE, Kim MW, Kim SH, Han JK. Clinical value of CT/MR-US fusion imaging for radiofrequency ablation of hepatic nodules. Eur J Radiol 2012; 81:2281-9. [DOI: 10.1016/j.ejrad.2011.08.013] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2011] [Revised: 08/17/2011] [Accepted: 08/22/2011] [Indexed: 12/29/2022]
|
120
|
Abstract
Based on recent clinical practice guidelines, imaging is largely replacing pathology as the preferred diagnostic method for determination of hepatocellular carcinoma (HCC). A variety of imaging modalities, including ultrasound (US), computed tomography (CT), magnetic resonance imaging (MRI), nuclear medicine, and angiography, are currently used to examine patients with chronic liver disease and suspected HCC. Advancements in imaging techniques such as perfusion imaging, diffusion imaging, and elastography along with the development of new contrast media will further improve the ability to detect and characterize HCC. Early diagnosis of HCC is essential for prompt treatment, which may in turn improve prognosis. Considering the process of hepatocarcinogenesis, it is important to evaluate sequential changes via imaging which would help to differentiate HCC from premalignant or benign lesions. Recent innovations including multiphasic examinations, high-resolution imaging, and the increased functional capabilities available with contrast-enhanced US, multidetector row CT, and MRI have raised the standards for HCC diagnosis. Although hemodynamic features of nodules in the cirrhotic liver remain the main diagnostic criterion, newly developed cellspecific contrast agents have shown great possibilities for improved HCC diagnosis and may overcome the diagnostic dilemma associated with small or borderline hepatocellular lesions. In the 20th century paradigm of medical imaging, radiological diagnosis was based on morphological characteristics, but in the 21st century, a paradigm shift to include biomedical, physiological, functional, and genetic imaging is needed. A multidisciplinary team approach is necessary to foster an integrated approach to HCC imaging. By developing and combining new imaging modalities, all phases of HCC patient care, including screening, diagnosis, treatment, and therapy, can be dramatically improved.
Collapse
|
121
|
Ryoo I, Lee JM, Park HS, Han JK, Choi BI. Preoperative assessment of longitudinal extent of bile duct cancers using MDCT with multiplanar reconstruction and minimum intensity projections: Comparison with MR cholangiography. Eur J Radiol 2012; 81:2020-6. [DOI: 10.1016/j.ejrad.2011.06.007] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2011] [Accepted: 06/01/2011] [Indexed: 01/26/2023]
|
122
|
Kim WH, Chang JM, Kim C, Park J, Yoo Y, Moon WK, Cho N, Choi BI. Synthetic aperture imaging in breast ultrasound: a preliminary clinical study. Acad Radiol 2012; 19:923-9. [PMID: 22633005 DOI: 10.1016/j.acra.2012.04.005] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2012] [Revised: 04/02/2012] [Accepted: 04/02/2012] [Indexed: 11/18/2022]
Abstract
RATIONALE AND OBJECTIVES To compare the image quality between conventional and synthetic aperture (SA) imaging in breast ultrasound (US). MATERIALS AND METHODS Twenty-four patients with 31 breast lesions were included in our study. The US data were processed with SA algorithm. For quantitative analysis, contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were calculated. For qualitative analysis, conventional and SA images were reviewed by three radiologists and diagnostic preference (conspicuity, margin sharpness, and contrast) was assessed. The radiologists also determined whether artifacts were present. Parameters were analyzed using a paired t-test, Wilcoxon signed-rank test, and chi-square test. RESULTS The mean CNRs were higher in SA images compared with conventional images (mean, 2.56 versus 2.28, P = .004). The mean SNRs were higher in SA images compared with conventional images (31.62 versus 25.26, P < .0001). SA images were considered as being "better" or "much better" in 16-23 (51.6-74.2%) lesions of total 31 lesions for conspicuity, in 17-24 (45.2%-77.4%) for margin sharpness, and in 13-23 (41.9%-74.2%) for contrast. Significant preferences in SA images were demonstrated (conspicuity, P < .05 for all radiologists; margin sharpness and contrast in two radiologists). Refraction and speckle artifacts were less frequently observed in SA images (refraction, P < .05 for all radiologists; speckle, P < .05 for two radiologists), whereas reflection artifacts were more frequent in SA images (P < .05 in two radiologists). CONCLUSION SA imaging provides better image quality than conventional imaging in patients with focal breast lesions in breast US.
Collapse
|
123
|
Lee JY, Choi BI, Son KR, Lee JM, Kim SJ, Park HS, Chang JM, Choi SH, Kim MA, Moon WK. Lymph node metastases from gastric cancer: gadofluorine M and gadopentetate dimeglumine MR imaging in a rabbit model. Radiology 2012; 263:391-400. [PMID: 22517957 DOI: 10.1148/radiol.000102431] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To compare the diagnostic performance of gadofluorine M with that of gadopentetate dimeglumine in the diagnosis of lymph node metastases with magnetic resonance (MR) imaging in a rabbit model of gastric cancer. MATERIALS AND METHODS The study protocol was approved by the institutional animal care committee. VX2 carcinomas were inoculated into the wall of the stomach in 20 rabbits. Gadopentetate dimeglumine-enhanced MR imaging was performed 4-6 weeks after inoculation, and gadofluorine M-enhanced MR imaging was performed approximately 24 hours later. Both MR imaging sets were analyzed separately and independently by four radiologists with respect to confidence level regarding the presence of metastases in lymph nodes and lymph node conspicuity. Statistical analysis was performed by using multiple-reader multiple-case (MRMC) receiver operating characteristic curve analysis and the Wilcoxon signed rank test. RESULTS Metastases were confirmed at pathologic analysis in 32 of 104 lymph nodes from 16 rabbits. The area under the receiver operating characteristic curve (AUC) for confidence regarding the presence of metastases in lymph nodes was significantly greater for gadofluorine M than for gadopentetate dimeglumine (AUC, 0.947 vs 0.894; P = .009). However, most (81%, 25 of 32) metastatic nodes were necrotic, and no significant difference was obtained in nonnecrotic nodes. For lymph node conspicuity, the gadofluorine M MR imaging set was assigned a significantly higher score than was the gadopentetate dimeglumine MR imaging set by all readers (P < .001). CONCLUSION Gadofluorine M showed significantly higher accuracy and better conspicuity than gadopentetate dimeglumine in the diagnosis of metastatic nodes, most of which were necrotic, in this animal model of gastric cancer.
Collapse
|
124
|
Kang Y, Lee JM, Kim SH, Han JK, Choi BI. Intrahepatic mass-forming cholangiocarcinoma: enhancement patterns on gadoxetic acid-enhanced MR images. Radiology 2012; 264:751-60. [PMID: 22798225 DOI: 10.1148/radiol.12112308] [Citation(s) in RCA: 134] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
PURPOSE To evaluate the enhancement patterns of intrahepatic mass-forming cholangiocarcinomas (IMCCs) with emphasis on the hepatobiliary phase (HBP) of gadoxetic acid-enhanced magnetic resonance (MR) imaging. MATERIALS AND METHODS This retrospective study was institutional review board approved, and the requirement for informed consent was waived. Fifty patients (41 men, nine women; mean age, 62.3 years; range, 44-76 years) with IMCC underwent unenhanced and gadoxetic acid-enhanced T1- and T2-weighted MR imaging including dynamic phase and hepatobiliary phase imaging between May 2008 and December 2010. Signal intensity and enhancement patterns of lesions were compared with those of the liver parenchyma in each phase. Conspicuity and margin sharpness of lesions on dynamic phase and HBP images were rated on a 4- or 5-point scale and compared by using the Wilcoxon signed-rank test. Percentage of relative enhancement was compared among pathologic subgroups by using the unpaired Student t test. RESULTS On dynamic phase images, 29 of 48 (60%) lesions showed a thin peripheral rim with centripetal or gradual progression. On HBP images, 48 of 50 (96%) IMCCs were hypointense, and two of 50 (4%) were hyperintense. Subjective ratings of conspicuity and margin sharpness were significantly higher on HBP (median scores, 5 and 4, respectively) (P < .001) than on the dynamic phase (median scores, 4 and 3, respectively) images (P < .001). Additional daughter nodules were found in five patients and intrahepatic metastasis was found in one. Percentage of relative enhancement on HBP images was significantly higher in moderately differentiated (66.4% ± 42.1) than in poorly differentiated (36.84% ± 21.5) tumors (P = .039) and in patients without (59.7% ± 28.8) than in those with (24.9% ± 14.7) (P = .036) lymph node metastasis. CONCLUSION The most prevalent enhancement pattern on gadoxetic acid-enhanced MR images of IMCCs was a thin peripheral rim with internal heterogeneous enhancement during the dynamic phase. HBP images showed increased lesion conspicuity and better delineation of daughter nodules and intrahepatic metastasis, which may aid in the diagnosis of IMCC.
Collapse
|
125
|
Joe E, Lee JM, Kim KW, Lee KB, Kim SJ, Baek JH, Shin CI, Suh KS, Yi NJ, Han JK, Choi BI. Quantification of hepatic macrosteatosis in living, related liver donors using T1-independent, T2*-corrected chemical shift MRI. J Magn Reson Imaging 2012; 36:1124-30. [PMID: 22761083 DOI: 10.1002/jmri.23738] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2011] [Accepted: 05/21/2012] [Indexed: 12/15/2022] Open
Abstract
PURPOSE To evaluate the diagnostic implications of the iterative decomposition of water and fat using echo-asymmetry and the least-squares estimation (IDEAL) technique to detect hepatic steatosis (HS) in potential liver donors using histopathology as the reference standard. MATERIALS AND METHODS Forty-nine potential liver donors (32 male, 17 female; mean age, 31.7 years) were included. All patients were imaged using the in- and out-of-phase (IOP) gradient-echo (GRE) and IDEAL techniques on a 1.5 T MR scanner. To estimate the hepatic fat fraction (FF), two reviewers performed regions-of-interest measurement in 15 areas of the liver seen on the IOP images and on the IDEAL-FF images. The magnetic resonance imaging (MRI) and pathology values of macrosteatosis were correlated using the Pearson correlation coefficient. We analyzed the diagnostic performance of IOP imaging and IDEAL for detecting HS. RESULTS The results of the hepatic-FF estimated on IDEAL were well correlated with the histologic degree of macrosteatosis (γ = 0.902, P < 0.001). IDEAL showed 100% sensitivity and 91% specificity for detecting HS, and IOP imaging showed 87.5% sensitivity and 97% specificity, respectively. CONCLUSION IDEAL is a useful tool for the preoperative diagnosis of HS in potential living liver donors; it can also help to avoid unnecessary biopsies in these patients.
Collapse
|