101
|
Abe T, Chang EY, De Allie G, Ajose T, Nwokike C, Bakinde N. Rapid decline in ejection fraction and persistent elevation of troponin associated with cardiac amyloidosis. SAGE Open Med Case Rep 2020; 8:2050313X20923259. [PMID: 32547758 PMCID: PMC7249551 DOI: 10.1177/2050313x20923259] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2019] [Accepted: 04/05/2020] [Indexed: 01/15/2023] Open
Abstract
Cardiac amyloidosis is an increasingly recognized cause of heart failure. It remains underdiagnosed despite a significant morbidity and mortality rate. The mean survival in patients with cardiac amyloidosis is less than 1 year in untreated primary light-chain amyloidosis and less than 4 years in wild-type transthyretin amyloidosis. We report a unique case of a 78-year-old male with transthyretin cardiac amyloidosis, who presented with persistently elevated troponin and progressive heart failure unresponsive to conventional therapy. With this case, we would like to highlight the role of cardiac biomarkers in the early diagnosis of cardiac amyloidosis.
Collapse
|
102
|
Ma YJ, Jang H, Chang EY, Hiniker A, Head BP, Lee RR, Corey-Bloom J, Bydder GM, Du J. Ultrashort echo time (UTE) magnetic resonance imaging of myelin: technical developments and challenges. Quant Imaging Med Surg 2020; 10:1186-1203. [PMID: 32550129 PMCID: PMC7276362 DOI: 10.21037/qims-20-541] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2020] [Accepted: 04/23/2020] [Indexed: 12/11/2022]
|
103
|
Byra M, Hentzen E, Du J, Andre M, Chang EY, Shah S. Assessing the Performance of Morphologic and Echogenic Features in Median Nerve Ultrasound for Carpal Tunnel Syndrome Diagnosis. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2020; 39:1165-1174. [PMID: 31868248 DOI: 10.1002/jum.15201] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2019] [Revised: 10/30/2019] [Accepted: 11/19/2019] [Indexed: 06/10/2023]
Abstract
OBJECTIVES To assess the feasibility of using ultrasound (US) image features related to the median nerve echogenicity and shape for carpal tunnel syndrome (CTS) diagnosis. METHODS In 31 participants (21 healthy participants and 10 patients with CTS), US images were collected with a 30-MHz transducer from median nerves at the wrist crease in 2 configurations: a neutral position and with wrist extension. Various morphologic features, including the cross-sectional area (CSA), were calculated to assess the nerve shape. Carpal tunnel syndrome commonly results in loss of visualization of the nerve fascicular pattern on US images. To assess this phenomenon, we developed a nerve-tissue contrast index (NTI) method. The NTI is a ratio of average brightness levels of surrounding tissue and the median nerve, both calculated on the basis of a US image. The area under the curve (AUC) from a receiver operating characteristic curve analysis and t test were used to assess the usefulness of the features for differentiation of patients with CTS from control participants. RESULTS We obtained significant differences in the CSA and NTI parameters between the patients with CTS and control participants (P < .01), with the corresponding highest AUC values equal to 0.885 and 0.938, respectively. For the remaining investigated morphologic features, the AUC values were less than 0.685, and the differences in means between the patients and control participants were not statistically significant (P > .10). The wrist configuration had no impact on differences in average parameter values (P > .09). CONCLUSIONS Patients with CTS can be differentiated from healthy individuals on the basis of the median nerve CSA and echogenicity. Carpal tunnel syndrome is not manifested in a change of the median nerve shape that could be related to circularity or contour variability.
Collapse
|
104
|
Ignas DM, Doria AS, von Drygalski A, Blanchette VS, Chang EY, Dover S, Fischer K, Gibikote S, Keshava SN, Querol F, Abad A, Babyn P. Use of ultrasound for assessment of musculoskeletal disease in persons with haemophilia: Results of an International Prophylaxis Study Group global survey. Haemophilia 2020; 26:685-693. [PMID: 32441402 DOI: 10.1111/hae.14006] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Accepted: 03/30/2020] [Indexed: 12/18/2022]
Abstract
AIM The objective of this survey was to understand the global trends of imaging assessments in persons with haemophilia, focusing on point-of-care ultrasound (POCUS). Insights into the barriers impeding its widespread proliferation as a frontline imaging modality were obtained. METHODS The survey opened in September of 2017 and closed in May of 2018. Haemophilia Treatment Centres (HTCs) treating both paediatric/adult patients were the population of interest. A REDCap survey of 25 questions was disseminated to 232 clinical staff in 26 countries. RESULTS The majority of respondents (88.3%, 91/103) reported that POCUS is most useful to confirm or rule out a presumed acute joint bleed. European HTCs reported the highest routine use of POCUS at 59.5% (22/37) followed by HTCs in the "Other" countries of the world at 46.7% (7/15) and North American HTCs at 43.9% (25/57). At the time of the survey, physiotherapists were identified as the clinical staff who perform POCUS 52.8% (28/53) of the time, in contrast with nurses/nurse practitioners who represent only 5.7% (3/53) of users. The greatest perceived barriers to the implementation of POCUS are the lack of trained healthcare professionals who can perform POCUS at 69.2% (74/107) and the overall time commitment required at 68.2% (73/107). CONCLUSION Despite POCUS being used in 49.5% (54/109) of sampled HTCs, it is still utilized almost 30% less globally than full diagnostic ultrasound. A list of barriers has been identified to inform HTCs which challenges they will likely need to overcome should they choose to incorporate this imaging modality into their practice.
Collapse
|
105
|
Wu M, Ma YJ, Kasibhatla A, Chen M, Jang H, Jerban S, Chang EY, Du J. Convincing evidence for magic angle less-sensitive quantitative T 1ρ imaging of articular cartilage using the 3D ultrashort echo time cones adiabatic T 1ρ (3D UTE cones-AdiabT 1ρ ) sequence. Magn Reson Med 2020; 84:2551-2560. [PMID: 32419199 DOI: 10.1002/mrm.28317] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2020] [Revised: 04/17/2020] [Accepted: 04/20/2020] [Indexed: 01/27/2023]
Abstract
PURPOSE To investigate the magic angle effect in three-dimensional ultrashort echo time Cones Adiabatic T1ρ (3D UTE Cones-AdiabT1ρ ) imaging of articular cartilage at 3T. METHODS The magic angle effect was investigated by repeated 3D UTE Cones-AdiabT1ρ imaging of eight human patellar samples at five angular orientations ranging from 0° to 90° relative to the B0 field. Cones continuous wave T1ρ (Cones-CW-T1ρ ) and Cones- T 2 ∗ sequences were also applied for comparison. Cones-AdiabT1ρ , Cones-CW-T1ρ and Cones- T 2 ∗ values were measured for four regions of interest (ROIs) (10% superficial layer, 60% transitional layer, 30% radial layer, and a global ROI) for each sample at each orientation to evaluate their angular dependence. RESULTS 3D UTE Cones-AdiabT1ρ values increased from the radial layer to the superficial layer for all angular orientations. The superficial layer showed the least angular dependence (around 4.4%), while the radial layer showed the strongest angular dependence (around 34.4%). Cones-AdiabT1ρ values showed much reduced magic angle effect compared to Cones-CW-T1ρ and Cones- T 2 ∗ values for all four ROIs. On average over eight patellae, Cones-AdiabT1ρ values increased by 27.2% (4.4% for superficial, 23.8% for transitional, and 34.4% for radial layers), Cones-CW-T1ρ values increased by 76.9% (11.3% for superficial, 59.1% for transitional, and 117.8% for radial layers), and Cones- T 2 ∗ values increased by 237.5% (87.9% for superficial, 262.9% for transitional, and 327.3% for radial layers) near the magic angle. CONCLUSIONS The 3D UTE Cones-AdiabT1ρ sequence is less sensitive to the magic angle effect in the evaluation of articular cartilage compared to Cones- T 2 ∗ and Cones-CW-T1ρ .
Collapse
|
106
|
Gorbachova T, Chang EY, Ha AS, Amini B, Dorfman SR, Fox MG, Khurana B, Klitzke A, Lee KS, Mooar PA, Shah KH, Shah NA, Singer AD, Smith SE, Taljanovic MS, Thomas JM, Kransdorf MJ. ACR Appropriateness Criteria® Acute Trauma to the Foot. J Am Coll Radiol 2020; 17:S2-S11. [PMID: 32370964 DOI: 10.1016/j.jacr.2020.01.019] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2020] [Accepted: 01/22/2020] [Indexed: 12/26/2022]
Abstract
Acute injuries to the foot are frequently encountered in the emergency room and in general practice settings. This publication defines best practices for imaging evaluations for several variants of patients presenting with acute foot trauma. The variants include scenarios when the Ottawa rules can be evaluated, when there are exclusionary criteria, and when suspected pathology is in anatomic areas not addressed by the Ottawa rules. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.
Collapse
|
107
|
Jang H, Carl M, Ma Y, Searleman AC, Jerban S, Chang EY, Corey-Bloom J, Du J. Inversion recovery zero echo time (IR-ZTE) imaging for direct myelin detection in human brain: a feasibility study. Quant Imaging Med Surg 2020; 10:895-906. [PMID: 32489915 DOI: 10.21037/qims.2020.04.13] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Background Myelin alteration is closely associated with neurological diseases such as multiple sclerosis (MS). Unfortunately, due to myelin's extremely short T2* (~0.3 ms or shorter at 3T), it cannot be directly imaged with conventional MR imaging techniques. Recently, ultrashort echo time (UTE) imaging-based methods have been proposed for direct imaging of myelin. In this study, we explore the feasibility and efficacy of inversion recovery prepared zero echo time (IR-ZTE) imaging for direct volumetric imaging of myelin in white matter of the brain in vivo. Methods In the proposed method, an adiabatic IR preparation pulse is used to suppress long T2 white matter signal, followed by dual echo ZTE imaging where the remaining long T2 components, including gray matter, are suppressed by dual echo subtraction. In the implementation of ZTE, the sampling strategy introduced in Water- and Fat-Suppressed Proton Projection MRI (WASPI) was incorporated to acquire the k-space data missing due to the radiofrequency (RF) transmit/receiver switching time. The IR-ZTE sequence was implemented on a 3T clinical MR system and evaluated using a myelin phantom composed of six different myelin concentrations (0% to 20%), a cadaveric human brain, four healthy volunteers, and seven MS patients. Results In the myelin phantom experiment, the ZTE signal intensity showed high linearity to the myelin concentrations (R2=0.98). In the ex vivo and in vivo experiments, the IR-ZTE sequence provided high contrast volumetric imaging of myelin in human brains. The IR-ZTE sequence was able to detect demyelinated foci lesions in all MS patients. Conclusions Adiabatic IR prepared dual echo ZTE imaging allows for direct, volumetric imaging of myelin in white matter of the brain in vivo.
Collapse
|
108
|
Taljanovic MS, Chang EY, Ha AS, Bartolotta RJ, Bucknor M, Chen KC, Gorbachova T, Khurana B, Klitzke AK, Lee KS, Mooar PA, Nguyen JC, Ross AB, Shih RD, Singer AD, Smith SE, Thomas JM, Yost WJ, Kransdorf MJ. ACR Appropriateness Criteria® Acute Trauma to the Knee. J Am Coll Radiol 2020; 17:S12-S25. [PMID: 32370956 DOI: 10.1016/j.jacr.2020.01.041] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2020] [Accepted: 01/27/2020] [Indexed: 11/20/2022]
Abstract
Acute trauma to the knee is a common presentation seen in the emergency department. After a routine clinical examination, imaging is frequently performed to facilitate the diagnosis and almost always starts with radiographs. If clinically indicated, advanced cross-sectional imaging may then be performed for further evaluation. CT is often performed for preoperative planning of the complex tibial plateau and distal femur fractures. Currently, MRI is the study of choice for evaluation of bone marrow, internal derangements, and other soft-tissue injuries about the knee joint. In patients with knee dislocations, MR angiography may be performed simultaneously with MRI for evaluation of internal derangements and vascular injuries with less morbidity compared to conventional angiography. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.
Collapse
|
109
|
Ma YJ, Chen Y, Li L, Cai Z, Wei Z, Jerban S, Jang H, Chang EY, Du J. Trabecular bone imaging using a 3D adiabatic inversion recovery prepared ultrashort TE Cones sequence at 3T. Magn Reson Med 2020; 83:1640-1651. [PMID: 31631404 PMCID: PMC6982597 DOI: 10.1002/mrm.28027] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2019] [Revised: 09/02/2019] [Accepted: 09/12/2019] [Indexed: 12/21/2022]
Abstract
PURPOSE To investigate direct imaging of trabecular bone using a 3D adiabatic inversion recovery prepared ultrashort TE cones (3D IR-UTE-Cones) sequence. METHODS The proposed 3D IR-UTE-Cones sequence used a broadband adiabatic inversion pulse together with a short TR/TI combination to suppress signals from long T2 tissues such as muscle and marrow fat, followed by multispoke UTE acquisition to detect signal from short T2 water components in trabecular bone. The feasibility of this technique for robust suppression of long T2 tissues was first demonstrated through numerical simulations. The proposed IR-UTE-Cones sequence was applied to a hip agarose bone phantom and to 6 healthy volunteers for morphologic and quantitative T 2 ∗ and proton density mapping of trabecular bone. RESULTS Numeric simulation suggests that the IR technique with a short TR/TI combination provides sufficient suppression of long T2 tissues with a wide range of T1 s. High contrast imaging of trabecular bone can be achieved ex vivo and in vivo, with fitted T 2 ∗ values of 0.3-0.45 ms and proton densities of 5-9 mol/L. CONCLUSION The 3D IR-UTE-Cones sequence with a short TR/TI combination provides robust suppression of long T2 tissues and allows both selective imaging and quantitative ( T 2 ∗ and proton density) assessment of short T2 water components in trabecular bone in vivo.
Collapse
|
110
|
Ashir A, Ma Y, Jerban S, Jang H, Wei Z, Le N, Du J, Chang EY. Rotator Cuff Tendon Assessment in Symptomatic and Control Groups Using Quantitative MRI. J Magn Reson Imaging 2020; 52:864-872. [PMID: 32129560 DOI: 10.1002/jmri.27115] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2020] [Revised: 02/14/2020] [Accepted: 02/18/2020] [Indexed: 11/09/2022] Open
Abstract
BACKGROUND Relatively weak correlations between patient symptoms and rotator cuff tendon (RCT) tearing have been reported; however, the relationship between symptoms and tendinosis has been less well-studied. PURPOSE/HYPOTHESIS To use quantitative MRI to assess the bilateral RCTs in shoulders of both patients with unilateral symptomatic tendinopathy and control subjects. We hypothesized that quantitative MRI measures would differ between symptomatic patients and controls. STUDY TYPE Prospective imaging study. POPULATION/SUBJECTS In all, 48 shoulders from 24 subjects (mean age, 32.8 years), including 14 patients with unilateral symptomatic tendinopathy and 10 asymptomatic controls. FIELD STRENGTH/SEQUENCE 3T/3D ultrashort echo time Cones sequence with magnetization transfer preparation (UTE-Cones-MT) and Carr-Purcell-Meiboom-Gill. ASSESSMENT Macromolecular fraction (MMF) and T2 relaxation were measured in four regions of the superior RCT, including all-segments, and lateral-third, bursal-sided, and articular-sided segments. The Western Ontario Rotator Cuff (WORC) index and visual analog scale were assessed. STATISTICAL TESTS Three shoulder groups were evaluated, including symptomatic shoulders, contralateral asymptomatic shoulders in patients, and asymptomatic controls. MMF and T2 values were compared between groups using a bootstrap-based comparison of means. RESULTS Significant differences were found in both MMF and T2 values between symptomatic and control RCTs when analyzing all-segments (P = 0.027 and P = 0.006, respectively) and articular-sided segments (both P = 0.001). Significant differences between asymptomatic RCTs in patients and control RCTs were also found, including MMF in all four anatomic regions analyzed (P = 0.024-0.044), as well as T2 in all-segments (P = 0.003), bursal-sided segments (P = 0.021), and articular-sided segments (P = 0.002). No significant differences in MMF (P = 0.420-0.950) or T2 (P = 0.380-0.910) were seen between ipsilateral symptomatic and contralateral asymptomatic RCTs in patients. DATA CONCLUSION Symptomatic RCTs showed significantly lower MMF values and higher T2 values compared with control RCTs. In patients with unilateral symptomatic tendinopathy, the contralateral shoulder can demonstrate asymptomatic tendinopathy, which can be quantified using MMF or T2 . EVIDENCE LEVEL 2 TECHNICAL EFFICACY: Stage 2. J. Magn. Reson. Imaging 2020;52:864-872.
Collapse
|
111
|
Jerban S, Lu X, Dorthe EW, Alenezi S, Ma Y, Kakos L, Jang H, Sah RL, Chang EY, D’Lima D, Du J. Correlations of cortical bone microstructural and mechanical properties with water proton fractions obtained from ultrashort echo time (UTE) MRI tricomponent T2* model. NMR IN BIOMEDICINE 2020; 33:e4233. [PMID: 31820518 PMCID: PMC7161421 DOI: 10.1002/nbm.4233] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2019] [Revised: 10/31/2019] [Accepted: 11/06/2019] [Indexed: 05/12/2023]
Abstract
Mechanical and microstructural evaluations of cortical bone using ultrashort echo time magnetic resonance imaging (UTE-MRI) have been performed increasingly in recent years. UTE-MRI acquires considerable signal from cortical bone and enables quantitative bone evaluations. Fitting bone apparent transverse magnetization (T2*) decay using a bicomponent model has been regularly performed to estimate bound water (BW) and pore water (PW) in the quantification of bone matrix and porosity, respectively. Human cortical bone possesses a considerable amount of fat, which appears as MRI T2* signal oscillation and can subsequently lead to BW overestimation when using a bicomponent model. Tricomponent T2* fitting model has been developed to improve BW and PW estimations by accounting for fat contribution in the MRI signal. This study aimed to investigate the correlations of microstructural and mechanical properties of human cortical bone with water pool fractions obtained from a tricomponent T2* model. 135 cortical bone strips (~4 × 2 × 40 mm3 ) from tibial and femoral midshafts of 37 donors (61 ± 24 years old) were scanned using ten sets of dual-echo 3D-UTE-Cones sequences (TE = 0.032-24.0 ms) on a 3 T MRI scanner for T2* fitting analyses. Average bone porosity and pore size were measured using microcomputed tomography (μCT) at 9 μm voxel size. Bone mechanical properties were measured using 4-point bending tests. Using a tricomponent model, bound water fraction (FracBW ) showed significant strong (R = 0.70, P < 0.01) and moderate (R = 0.58-0.62, P < 0.01) correlations with porosity and mechanical properties, respectively. Correlations of bone microstructural and mechanical properties with water pool fractions were higher for tricomponent model results compared with the bicomponent model. The tricomponent T2* fitting model is suggested as a useful technique for cortical bone evaluation where the MRI contribution of bone fat is accounted for.
Collapse
|
112
|
Byra M, Wu M, Zhang X, Jang H, Ma YJ, Chang EY, Shah S, Du J. Knee menisci segmentation and relaxometry of 3D ultrashort echo time cones MR imaging using attention U-Net with transfer learning. Magn Reson Med 2020; 83:1109-1122. [PMID: 31535731 PMCID: PMC6879791 DOI: 10.1002/mrm.27969] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2019] [Revised: 07/11/2019] [Accepted: 08/04/2019] [Indexed: 12/24/2022]
Abstract
PURPOSE To develop a deep learning-based method for knee menisci segmentation in 3D ultrashort echo time (UTE) cones MR imaging, and to automatically determine MR relaxation times, namely the T1, T1ρ , and T 2 ∗ parameters, which can be used to assess knee osteoarthritis (OA). METHODS Whole knee joint imaging was performed using 3D UTE cones sequences to collect data from 61 human subjects. Regions of interest (ROIs) were outlined by 2 experienced radiologists based on subtracted T1ρ -weighted MR images. Transfer learning was applied to develop 2D attention U-Net convolutional neural networks for the menisci segmentation based on each radiologist's ROIs separately. Dice scores were calculated to assess segmentation performance. Next, the T1, T1ρ , T 2 ∗ relaxations, and ROI areas were determined for the manual and automatic segmentations, then compared. RESULTS The models developed using ROIs provided by 2 radiologists achieved high Dice scores of 0.860 and 0.833, while the radiologists' manual segmentations achieved a Dice score of 0.820. Linear correlation coefficients for the T1, T1ρ , and T 2 ∗ relaxations calculated using the automatic and manual segmentations ranged between 0.90 and 0.97, and there were no associated differences between the estimated average meniscal relaxation parameters. The deep learning models achieved segmentation performance equivalent to the inter-observer variability of 2 radiologists. CONCLUSION The proposed deep learning-based approach can be used to efficiently generate automatic segmentations and determine meniscal relaxations times. The method has the potential to help radiologists with the assessment of meniscal diseases, such as OA.
Collapse
|
113
|
Ma YJ, Searleman AC, Jang H, Wong J, Chang EY, Corey-Bloom J, Bydder GM, Du J. Whole-Brain Myelin Imaging Using 3D Double-Echo Sliding Inversion Recovery Ultrashort Echo Time (DESIRE UTE) MRI. Radiology 2020; 294:362-374. [PMID: 31746689 PMCID: PMC6996715 DOI: 10.1148/radiol.2019190911] [Citation(s) in RCA: 38] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2019] [Revised: 08/21/2019] [Accepted: 08/30/2019] [Indexed: 11/11/2022]
Abstract
Background Signal contamination from long T2 water is a major challenge in direct imaging of myelin with MRI. Nulling of the unwanted long T2 signals can be achieved with an inversion recovery (IR) preparation pulse to null long T2 white matter within the brain. The remaining ultrashort T2 signal from myelin can be detected with an ultrashort echo time (UTE) sequence. Purpose To develop patient-specific whole-brain myelin imaging with a three-dimensional double-echo sliding inversion recovery (DESIRE) UTE sequence. Materials and Methods The DESIRE UTE sequence generates a series of IR images with different inversion times during a single scan. The optimal inversion time for nulling long T2 signal is determined by finding minimal signal on the second echo. Myelin images are generated by subtracting the second echo image from the first UTE image. To validate this method, a prospective study was performed in phantoms, cadaveric brain specimens, healthy volunteers, and patients with multiple sclerosis (MS). A total of 20 healthy volunteers (mean age, 40 years ± 13 [standard deviation], 10 women) and 20 patients with MS (mean age, 58 years ± 8; 15 women) who underwent MRI between November 2017 and February 2019 were prospectively included. Analysis of variance was performed to evaluate the signal difference between MS lesions and normal-appearing white matter in patients with MS. Results High signal intensity and corresponding T2* and T1 of the extracted myelin vesicles provided evidence for direct imaging of ultrashort-T2 myelin protons using the UTE sequence. Gadobenate dimeglumine phantoms with a wide range of T1 values were selectively suppressed with DESIRE UTE. In the ex vivo brain study of MS lesions, signal loss was observed in MS lesions and was conformed with histologic analysis. In the human study, there was a significant reduction in normalized signal intensity in MS lesions compared with that in normal-appearing white matter (0.19 ± 0.10 vs 0.76 ± 0.11, respectively; P < .001). Conclusion The double-echo sliding inversion recovery ultrashort echo time sequence can generate whole-brain myelin images specifically with a clinical 3-T scanner. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Port in this issue.
Collapse
|
114
|
Jerban S, Ma Y, Jang H, Namiranian B, Le N, Shirazian H, Murphy ME, Du J, Chang EY. Water proton density in human cortical bone obtained from ultrashort echo time (UTE) MRI predicts bone microstructural properties. Magn Reson Imaging 2020; 67:85-89. [PMID: 31931112 DOI: 10.1016/j.mri.2020.01.004] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2019] [Revised: 01/08/2020] [Accepted: 01/10/2020] [Indexed: 12/16/2022]
Abstract
PURPOSE To investigate the correlations between cortical bone microstructural properties and total water proton density (TWPD) obtained from three-dimensional ultrashort echo time Cones (3D-UTE-Cones) magnetic resonance imaging techniques. MATERIALS AND METHODS 135 cortical bone samples were harvested from human tibial and femoral midshafts of 37 donors (61 ± 24 years old). Samples were scanned using 3D-UTE-Cones sequences on a clinical 3T MRI and on a high-resolution micro-computed tomography (μCT) scanner. TWPD was measured using 3D-UTE-Cones MR images. Average bone porosity, pore size, and bone mineral density (BMD) were measured from μCT images at 9 μm voxel size. Pearson's correlation coefficients between TWPD and μCT-based measures were calculated. RESULTS TWPD showed significant moderate correlation with both average bone porosity (R = 0.66, p < 0.01) and pore size (R = 0.57, p < 0.01). TWPD also showed significant strong correction with BMD (R = 0.71, p < 0.01). CONCLUSIONS The presented 3D-UTE-Cones imaging technique allows assessment of TWPD in human cortical bone. This quick UTE-MRI-based technique was capable of predicting bone microstructure differences with significant correlations. Such correlations highlight the potential of UTE-MRI-based measurement of bone water proton density to assess bone microstructure.
Collapse
|
115
|
Jerban S, Chang DG, Ma Y, Jang H, Chang EY, Du J. An Update in Qualitative Imaging of Bone Using Ultrashort Echo Time Magnetic Resonance. Front Endocrinol (Lausanne) 2020; 11:555756. [PMID: 33117275 PMCID: PMC7551122 DOI: 10.3389/fendo.2020.555756] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/26/2020] [Accepted: 09/11/2020] [Indexed: 12/31/2022] Open
Abstract
Bone is comprised of mineral, collagenous organic matrix, and water. X-ray-based techniques are the standard approach for bone evaluation in clinics, but they are unable to detect the organic matrix and water components in bone. Magnetic resonance imaging (MRI) is being used increasingly for bone evaluation. While MRI can non-invasively assess the proton pools in soft tissues, cortical bone typically appears as a signal void with clinical MR techniques because of its short T2*. New MRI techniques have been recently developed to image bone while avoiding the ionizing radiation present in x-ray-based methods. Qualitative bone imaging can be achieved using ultrashort echo time (UTE), single inversion recovery UTE (IR-UTE), dual-inversion recovery UTE (Dual-IR-UTE), double-inversion recovery UTE (Double-IR-UTE), and zero echo time (ZTE) sequences. The contrast mechanisms as well as the advantages and disadvantages of each technique are discussed.
Collapse
|
116
|
Wu M, Zhao W, Wan L, Kakos L, Li L, Jerban S, Jang H, Chang EY, Du J, Ma YJ. Quantitative three-dimensional ultrashort echo time cones imaging of the knee joint with motion correction. NMR IN BIOMEDICINE 2020; 33:e4214. [PMID: 31713936 PMCID: PMC7197345 DOI: 10.1002/nbm.4214] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2019] [Revised: 10/01/2019] [Accepted: 10/18/2019] [Indexed: 05/16/2023]
Abstract
Knee degeneration involves all the major tissues in the joint. However, conventional MRI sequences can only detect signals from long T2 tissues such as the superficial cartilage, with little signal from the deep cartilage, menisci, ligaments, tendons and bone. It is highly desirable to develop new sequences that can detect signal from all major tissues in the knee. We aimed to develop a comprehensive quantitative three-dimensional ultrashort echo time (3D UTE) cones imaging protocol for a truly "whole joint" evaluation of knee degeneration. The protocol included 3D UTE cones actual flip angle imaging (3D UTE-Cones-AFI) for T1 mapping, multiecho UTE-Cones with fat suppression for T2 * mapping, UTE-Cones with adiabatic T1ρ (AdiabT1ρ ) preparation for AdiabT1ρ mapping, and UTE-Cones magnetization transfer (UTE-Cones-MT) for MT ratio (MTR) and modeling of macromolecular proton fraction (f). An elastix registration technique was used to compensate for motion during scans. Quantitative data analyses were performed on the registered data. Three knee specimens and 15 volunteers were evaluated at 3 T. The elastix motion correction algorithm worked well in correcting motion artifacts associated with relatively long scan times. Much improved curve fitting was achieved for all UTE-Cones biomarkers with greatly reduced root mean square errors. The averaged T1 , T2 *, AdiabT1ρ , MTR and f for knee joint tissues of 15 healthy volunteers were reported. The 3D UTE-Cones quantitative imaging techniques (ie, T1 , T2 *, AdiabT1ρ , MTR and MT modeling) together with elastix motion correction provide robust volumetric measurement of relaxation times, MTR and f of both short and long T2 tissues in the knee joint.
Collapse
|
117
|
Guo T, Ma Y, Jerban S, Jang H, Zhao W, Chang EY, Chen M, Bydder GM, Du J. T 1 measurement of bound water in cortical bone using 3D adiabatic inversion recovery ultrashort echo time (3D IR-UTE) Cones imaging. Magn Reson Med 2019; 84:634-645. [PMID: 31863519 DOI: 10.1002/mrm.28140] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2019] [Revised: 11/04/2019] [Accepted: 11/30/2019] [Indexed: 11/11/2022]
Abstract
PURPOSE We describe the measurement of bound water T1 ( T 1 BW ) of cortical bone in vitro and in vivo with a 3D adiabatic inversion recovery ultrashort echo time (IR-UTE) Cones sequence using a clinical 3T scanner. METHODS A series IR-UTE data from 6 repetition times (TRs) with 5 inversion times (TIs) at each TR were acquired from 12 human tibial bone specimens, and data from 4 TRs with 5 TIs at each TR were acquired from the tibial midshafts of 8 healthy volunteers. The pore water nulling point was calculated from exponential fitting of the inversion recovery curve at each TR. Bone specimens and volunteers were then scanned again with the calculated nulling point at each TR. T 1 BW was derived through exponential fitting of data from IR-UTE images acquired at different TRs using the calculated pore water nulling point for each TR. RESULTS In vitro pore water nulling TIs were 141.3 ± 11.6, 123.4 ± 8.9, 101.3 ± 6.2, 88.9 ± 5.3, 74.8 ± 4.2, and 59.2 ± 3.9 ms for the 6 TRs of 500, 400, 300, 250, 200, and 150 ms, respectively. In vivo pore water nulling TIs were 132.8 ± 12.8, 110.3 ± 10.0, 80.0 ± 7.2, and 63.9 ± 5.4 ms for the 4 TRs of 400, 300, 200, and 150 ms, respectively. Excellent exponential fitting was achieved for IR-UTE imaging of bound water with pore water nulled at each TR. The mean T 1 BW was 106.9 ± 6.3 ms in vitro and 112.3 ± 16.4 ms in vivo. CONCLUSION Using the 3D IR-UTE Cones with a variable TR/TI approach, T 1 BW of cortical bone was calculated after complete nulling of pore water signals.
Collapse
|
118
|
Chang EY. Editorial on "Multiparametric MR Investigation of Proteoglycan Diffusivity, T 2 Relaxation, and Concentration in an ex vivo Model of Intervertebral Disc Degeneration". J Magn Reson Imaging 2019; 51:1401-1402. [PMID: 31794103 DOI: 10.1002/jmri.27010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Accepted: 11/19/2019] [Indexed: 11/09/2022] Open
|
119
|
Jerban S, Ma Y, Namiranian B, Ashir A, Shirazian H, Wei Z, Le N, Wu M, Cai Z, Du J, Chang EY. Age-related decrease in collagen proton fraction in tibial tendons estimated by magnetization transfer modeling of ultrashort echo time magnetic resonance imaging (UTE-MRI). Sci Rep 2019; 9:17974. [PMID: 31784631 PMCID: PMC6884538 DOI: 10.1038/s41598-019-54559-3] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2019] [Accepted: 11/11/2019] [Indexed: 12/12/2022] Open
Abstract
Clinical magnetic resonance imaging (MRI) sequences are not often capable of directly visualizing tendons. Ultrashort echo time (UTE) MRI can acquire high signal from tendons thus enabling quantitative assessments. Magnetization transfer (MT) modeling combined with UTE-MRI—UTE-MT-modeling—can indirectly assess macromolecular protons in the tendon. This study aimed to determine if UTE-MT-modeling is a quantitative technique sensitive to the age-related changes of tendons. The legs of 26 young healthy (29 ± 6 years old) and 22 elderly (75 ± 8 years old) female subjects were imaged using UTE sequences on a 3T MRI scanner. Institutional review board approval was obtained, and all recruited subjects provided written informed consent. T1 and UTE-MT-modeling were performed on anterior tibialis tendons (ATT) and posterior tibialis tendons (PTT) as two representative human leg tendons. A series of MT pulse saturation powers (500–1500°) and frequency offsets (2–50 kHz) were used to measure the macromolecular fraction (MMF) and macromolecular T2 (T2MM). All measurements were repeated by three independent readers for a reproducibility study. MMF demonstrated significantly lower values on average in the elderly cohort compared with the younger cohort for both ATT (decreased by 16.8%, p = 0.03) and PTT (decreased by 23.0%, p < 0.01). T2MM and T1 did not show a significant nor a consistent difference between the young and elderly cohorts. For all MRI parameters, intraclass correlation coefficient (ICC) was higher than 0.98, indicating excellent consistency between measurements performed by independent readers. MMF serving as a surrogate measure for collagen content, showed a significant decrease in elderly leg tendons. This study highlighted UTE-MRI-MT techniques as a useful quantitative method to assess the impact of aging on human tendons.
Collapse
|
120
|
Jang H, Wei Z, Wu M, Ma YJ, Chang EY, Corey-Bloom J, Du J. Improved volumetric myelin imaging in human brain using 3D dual echo inversion recovery-prepared UTE with complex echo subtraction. Magn Reson Med 2019; 83:1168-1177. [PMID: 31746487 DOI: 10.1002/mrm.28082] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2019] [Revised: 10/18/2019] [Accepted: 10/24/2019] [Indexed: 12/17/2022]
Abstract
PURPOSE Inversion recovery-based UTE (IR-UTE) sequences have been proposed to directly image myelin with extremely short T 2 ∗ (~0.3 ms). In this study, we demonstrate the feasibility of complex echo subtraction to improve 3D IR-UTE imaging of myelin in white matter of the brain in vivo. METHODS In IR-UTE imaging, long T2 components in white matter (i.e., water) are suppressed using an adiabatic inversion recovery preparation pulse. Dual echo UTE data acquisition and magnitude echo subtraction are used to suppress the residual white matter and gray matter signals, providing high myelin contrast. Complex echo subtraction may further improve the myelin contrast by reducing the residual long T2 water signal contamination caused by regional T1 variations. To verify the efficacy of the complex subtraction technique, in vivo experiments were performed with 5 non-symptomatic healthy volunteers and 5 multiple sclerosis patients on a 3T clinical MR system. Signal enhancement between the complex subtraction and the magnitude subtraction was introduced to evaluate the improvement. RESULTS The complex subtraction improved myelin contrast over the magnitude subtraction in both healthy and patient groups, with more fine myelin structures being revealed. The foci of the demyelinated lesion were more clearly detected by complex subtraction. An average signal enhancement of up to 135.9% was achieved with the complex subtraction over the magnitude subtraction. CONCLUSION The complex echo subtraction improves 3D IR-UTE morphologic imaging of myelin in white matter of the brain.
Collapse
|
121
|
Jerban S, Chang EY, Du J. Magnetic resonance imaging (MRI) studies of knee joint under mechanical loading: Review. Magn Reson Imaging 2019; 65:27-36. [PMID: 31670237 DOI: 10.1016/j.mri.2019.09.007] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2019] [Revised: 08/17/2019] [Accepted: 09/15/2019] [Indexed: 02/07/2023]
Abstract
Osteoarthritis (OA) is a very common disease that affects the human knee joint, particularly the articular cartilage and meniscus components which are regularly under compressive mechanical loads. Early-stage OA diagnosis is essential as it allows for timely intervention. The primary non-invasive approaches currently available for OA diagnosis include magnetic resonance imaging (MRI), which provides excellent soft tissue contrast at high spatial resolution. MRI-based knee investigation is usually performed on joints at rest or in a non-weight-bearing condition that does not mimic the actual physiological condition of the joint. This discrepancy may lead to missed detections of early-stage OA or of minor lesions. The mechanical properties of degenerated musculoskeletal (MSK) tissues may vary markedly before any significant morphological or structural changes detectable by MRI. Recognizing distinct deformation characteristics of these tissues under known mechanical loads may reveal crucial joint lesions or mechanical malfunctions which result from early-stage OA. This review article summarizes the large number of MRI-based investigations on knee joints under mechanical loading which have been reported in the literature including the corresponding MRI measures, the MRI-compatible devices employed, and potential challenges due to the limitations of clinical MRI sequences.
Collapse
|
122
|
Guo T, Ma YJ, High RA, Tang Q, Wong JH, Byra M, Searleman AC, To SC, Wan L, Le N, Du J, Chang EY. Assessment of an in vitro model of rotator cuff degeneration using quantitative magnetic resonance and ultrasound imaging with biochemical and histological correlation. Eur J Radiol 2019; 121:108706. [PMID: 31655315 DOI: 10.1016/j.ejrad.2019.108706] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Revised: 09/10/2019] [Accepted: 10/09/2019] [Indexed: 02/06/2023]
Abstract
PURPOSE Quantitative imaging methods could improve diagnosis of rotator cuff degeneration, but the capability of quantitative MR and US imaging parameters to detect alterations in collagen is unknown. The goal of this study was to assess quantitative MR and US imaging measures for detecting abnormalities in collagen using an in vitro model of tendinosis with biochemical and histological correlation. METHOD 36 pieces of supraspinatus tendons from 6 cadaveric donors were equally distributed into 3 groups (2 subjected to different concentrations of collagenase and a control group). Ultrashort echo time MR and US imaging measures were performed to assess changes at baseline and after 24 h of enzymatic digestion. Biochemical and histological measures, including brightfield, fluorescence, and polarized microscopy, were used to verify the validity of the model and were compared with quantitative imaging parameters. Correlations between the imaging parameters and biochemically measured digestion were analyzed. RESULTS Among the imaging parameters, macromolecular fraction (MMF), adiabatic T1ρ, T2*, and backscatter coefficient (BSC) were useful in differentiating between the extent of degeneration among the 3 groups. MMF strongly correlated with collagen loss (r=-0.81; 95% confidence interval [CI]: -0.90,-0.66), while the adiabatic T1ρ (r = 0.66; CI: 0.42,0.81), T2* (r = 0.58; CI: 0.31,0.76), and BSC (r = 0.51; CI: 0.22,0.72) moderately correlated with collagen loss. CONCLUSIONS MMF, adiabatic T1ρ, and T2* measured and US BSC can detect alterations in collagen. Of the quantitative MR and US imaging measures evaluated, MMF showed the highest correlation with collagen loss and can be used to assess rotator cuff degeneration.
Collapse
|
123
|
Jerban S, Ma Y, Li L, Jang H, Wan L, Guo T, Searleman A, Chang EY, Du J. Volumetric mapping of bound and pore water as well as collagen protons in cortical bone using 3D ultrashort echo time cones MR imaging techniques. Bone 2019; 127:120-128. [PMID: 31176044 PMCID: PMC6708764 DOI: 10.1016/j.bone.2019.05.038] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2019] [Revised: 05/28/2019] [Accepted: 05/31/2019] [Indexed: 12/13/2022]
Abstract
Cortical bone assessment using magnetic resonance imaging (MRI) has recently received great attention in an effort to avoid the potential harm associated with ionizing radiation-based techniques. Ultrashort echo time MRI (UTE-MRI) techniques can acquire signal from major hydrogen proton pools in cortical bone, including bound and pore water, as well as from the collagen matrix. This study aimed to develop and evaluate the feasibility of a technique for mapping bound water, pore water, and collagen proton densities in human cortical bone ex vivo and in vivo using three-dimensional UTE Cones (3D-UTE-Cones) MRI. Eight human tibial cortical bone specimens (63 ± 19 years old) were scanned using 3D-UTE-Cones sequences on a clinical 3 T MRI scanner and a micro-computed tomography (μCT) scanner. Total, bound, and pore water proton densities (TWPD, BWPD, and PWPD, respectively) were measured using UTE and inversion recovery UTE (IR-UTE) imaging techniques. Macromolecular proton density (MMPD), a collagen representation, was measured using TWPD and macromolecular fraction (MMF) obtained from two-pool UTE magnetization transfer (UTE-MT) modeling. The correlations between proton densities and μCT-based measures were investigated. The 3D-UTE-Cones techniques were further applied on ten young healthy (34 ± 3 years old) and five old (78 ± 6 years old) female volunteers to evaluate the techniques' feasibility for translational clinical applications. In the ex vivo study, PWPD showed the highest correlations with bone porosity and bone mineral density (BMD) (R = 0.79 and - 0.70, p < 0.01). MMPD demonstrated moderate to strong correlations with bone porosity and BMD (R = -0.67 and 0.65, p < 0.01). MMPD showed strong correlation with age in specimens from female donors (R = -0.91, p = 0.03, n = 5). The presented comprehensive 3D-UTE-Cones imaging protocol allows quantitative mapping of protons in major pools of cortical bone ex vivo and in vivo. PWPD and MMPD can serve as potential novel biomarkers to assess bone matrix and microstructure, as well as bone age- or injury-related variations.
Collapse
|
124
|
High RA, Ji Y, Ma YJ, Tang Q, Murphy ME, Du J, Chang EY. In vivo assessment of extracellular pH of joint tissues using acidoCEST-UTE MRI. Quant Imaging Med Surg 2019; 9:1664-1673. [PMID: 31728310 DOI: 10.21037/qims.2019.08.11] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Background Degradation of cartilage and meniscus may be mediated by changes in extracellular pH. The purpose of this study was to optimize saturation powers used with the acidoCEST magnetic resonance imaging (MRI) technique with a 3D ultrashort echo time readout (acidoCEST-UTE) and to demonstrate feasibility of the method for measuring pH in cartilage and meniscus in vivo. Methods Magnetization transfer ratio asymmetry and ratio of radiofrequency (RF) power mismatch at different powers were evaluated in cartilage and meniscus tissue phantoms for iopamidol and iohexol. Using optimized RF powers, the acidoCEST-UTE MRI sequence was used to assess pH of joint fluid and tissues in four patients after direct intra-articular administration of iodinated contrast. Results In the phantoms, the ratio of powers 0.54/1.10 µT showed the strongest correlation with pH. In vivo acidoCEST-UTE pH measurements of intra-articular fluid were similar to electrode measurements of the contrast agent (7.22 vs. 7.1 for iopamidol, respectively; 7.65 vs. 7.5 for iohexol, respectively). As measured with the acidoCEST-UTE technique, overall mean cartilage pH was significantly lower than overall mean meniscus pH (6.60 vs. 6.72, respectively; P=0.043). Conclusions AcidoCEST-UTE MRI after direct intra-articular administration of either iopamidol or iohexol can be used to measure cartilage and meniscus pH in vivo.
Collapse
|
125
|
Jang H, Ma Y, Searleman AC, Carl M, Corey-Bloom J, Chang EY, Du J. Inversion recovery UTE based volumetric myelin imaging in human brain using interleaved hybrid encoding. Magn Reson Med 2019; 83:950-961. [PMID: 31532032 DOI: 10.1002/mrm.27986] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2019] [Revised: 07/12/2019] [Accepted: 08/15/2019] [Indexed: 12/11/2022]
Abstract
PURPOSE Direct myelin imaging can improve the characterization of myelin-related diseases such as multiple sclerosis. In this study, we explore a novel method to directly image myelin using inversion recovery-prepared hybrid encoding (IR-HE) UTE MRI. METHODS The IR-HE sequence uses an adiabatic inversion pulse to suppress the long T2 white matter signal, followed by 3D dual-echo HE utilizing both single point imaging and radial frequency encoding, for which the subtraction image between 2 echoes reveals the myelin signal with high contrast. To reduce scan time, it is common to obtain multiple spokes per IR. Here, we invented a novel method to improve the HE, adapted for the multi-spoke IR imaging-termed interleaved HE-for which single point imaging encoding is interleaved between radial frequency encodings near nulling point to allow more efficient IR-signal suppression. To evaluate the proposed approach, a computer simulation, myelin phantom experiment, an ex vivo experiment with a cadaveric multiple sclerosis brain, and an in vivo experiment with 8 healthy volunteers and 13 multiple sclerosis patients were performed. RESULTS The computer simulation showed that IR-interleaved HE allows for improved contrast of myelin signal with reduced imaging artifacts. The myelin phantom experiment showed IR-interleaved HE allows direct imaging of myelin lipid with excellent suppression of water signal. In the ex vivo and in vivo experiments, the proposed method demonstrated highly specific imaging of myelin in white matter of the brain. CONCLUSION IR-interleaved HE allows for time-efficient, high-contrast direct myelin imaging and can detect demyelinated lesions in multiple sclerosis patients.
Collapse
|