101
|
Li R, Emmerich MTM, Eggermont J, Bäck T, Schütz M, Dijkstra J, Reiber JHC. Mixed integer evolution strategies for parameter optimization. EVOLUTIONARY COMPUTATION 2012; 21:29-64. [PMID: 22122384 DOI: 10.1162/evco_a_00059] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Evolution strategies (ESs) are powerful probabilistic search and optimization algorithms gleaned from biological evolution theory. They have been successfully applied to a wide range of real world applications. The modern ESs are mainly designed for solving continuous parameter optimization problems. Their ability to adapt the parameters of the multivariate normal distribution used for mutation during the optimization run makes them well suited for this domain. In this article we describe and study mixed integer evolution strategies (MIES), which are natural extensions of ES for mixed integer optimization problems. MIES can deal with parameter vectors consisting not only of continuous variables but also with nominal discrete and integer variables. Following the design principles of the canonical evolution strategies, they use specialized mutation operators tailored for the aforementioned mixed parameter classes. For each type of variable, the choice of mutation operators is governed by a natural metric for this variable type, maximal entropy, and symmetry considerations. All distributions used for mutation can be controlled in their shape by means of scaling parameters, allowing self-adaptation to be implemented. After introducing and motivating the conceptual design of the MIES, we study the optimality of the self-adaptation of step sizes and mutation rates on a generalized (weighted) sphere model. Moreover, we prove global convergence of the MIES on a very general class of problems. The remainder of the article is devoted to performance studies on artificial landscapes (barrier functions and mixed integer NK landscapes), and a case study in the optimization of medical image analysis systems. In addition, we show that with proper constraint handling techniques, MIES can also be applied to classical mixed integer nonlinear programming problems.
Collapse
|
102
|
Boogers MJ, Broersen A, van Velzen JE, de Graaf FR, El-Naggar HM, Kitslaar PH, Dijkstra J, Delgado V, Boersma E, de Roos A, Schuijf JD, Schalij MJ, Reiber JHC, Bax JJ, Jukema JW. Automated quantification of coronary plaque with computed tomography: comparison with intravascular ultrasound using a dedicated registration algorithm for fusion-based quantification. Eur Heart J 2012; 33:1007-16. [PMID: 22285583 DOI: 10.1093/eurheartj/ehr465] [Citation(s) in RCA: 169] [Impact Index Per Article: 14.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
AIMS Previous studies have used semi-automated approaches for coronary plaque quantification on multi-detector row computed tomography (CT), while an automated quantitative approach using a dedicated registration algorithm is currently lacking. Accordingly, the study aimed to demonstrate the feasibility and accuracy of automated coronary plaque quantification on cardiac CT using dedicated software with a novel 3D coregistration algorithm of CT and intravascular ultrasound (IVUS) data sets. METHODS AND RESULTS Patients who had undergone CT and IVUS were enrolled. Automated lumen and vessel wall contour detection was performed for both imaging modalities. Dedicated automated quantitative software (QCT) with a unique registration algorithm was used to fuse a complete IVUS run with a CT angiography volume using true anatomical markers. At the level of the minimal lumen area (MLA), percentage lumen area stenosis, plaque burden, and degree of remodelling were obtained on CT. Additionally, mean plaque burden was assessed for the whole coronary plaque. At the identical level within the coronary artery, the same variables were derived from IVUS. Fifty-one patients (40 men, 58 ± 11 years, 103 coronary arteries) with 146 lesions were evaluated. Quantitative computed tomography and IVUS showed good correlation for MLA (n = 146, r = 0.75, P < 0.001). At the level of the MLA, both techniques were well-correlated for lumen area stenosis (n = 146, r = 0.79, P < 0.001) and plaque burden (n = 146, r = 0.70, P < 0.001). Mean plaque burden (n = 146, r = 0.64, P < 0.001) and remodelling index (n = 146, r = 0.56, P < 0.001) showed significant correlations between QCT and IVUS. CONCLUSION Automated quantification of coronary plaque on CT is feasible using dedicated quantitative software with a novel 3D registration algorithm.
Collapse
|
103
|
Tu S, Xu L, Ligthart J, Xu B, Witberg K, Sun Z, Koning G, Reiber JHC, Regar E. In vivo comparison of arterial lumen dimensions assessed by co-registered three-dimensional (3D) quantitative coronary angiography, intravascular ultrasound and optical coherence tomography. Int J Cardiovasc Imaging 2012; 28:1315-27. [PMID: 22261998 PMCID: PMC3463784 DOI: 10.1007/s10554-012-0016-6] [Citation(s) in RCA: 85] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2011] [Accepted: 01/04/2012] [Indexed: 12/18/2022]
Abstract
This study sought to compare lumen dimensions as assessed by 3D quantitative coronary angiography (QCA) and by intravascular ultrasound (IVUS) or optical coherence tomography (OCT), and to assess the association of the discrepancy with vessel curvature. Coronary lumen dimensions often show discrepancies when assessed by X-ray angiography and by IVUS or OCT. One source of error concerns a possible mismatch in the selection of corresponding regions for the comparison. Therefore, we developed a novel, real-time co-registration approach to guarantee the point-to-point correspondence between the X-ray, IVUS and OCT images. A total of 74 patients with indication for cardiac catheterization were retrospectively included. Lumen morphometry was performed by 3D QCA and IVUS or OCT. For quantitative analysis, a novel, dedicated approach for co-registration and lumen detection was employed allowing for assessment of lumen size at multiple positions along the vessel. Vessel curvature was automatically calculated from the 3D arterial vessel centerline. Comparison of 3D QCA and IVUS was performed in 519 distinct positions in 40 vessels. Correlations were r = 0.761, r = 0.790, and r = 0.799 for short diameter (SD), long diameter (LD), and area, respectively. Lumen sizes were larger by IVUS (P < 0.001): SD, 2.51 ± 0.58 mm versus 2.34 ± 0.56 mm; LD, 3.02 ± 0.62 mm versus 2.63 ± 0.58 mm; Area, 6.29 ± 2.77 mm2 versus 5.08 ± 2.34 mm2. Comparison of 3D QCA and OCT was performed in 541 distinct positions in 40 vessels. Correlations were r = 0.880, r = 0.881, and r = 0.897 for SD, LD, and area, respectively. Lumen sizes were larger by OCT (P < 0.001): SD, 2.70 ± 0.65 mm versus 2.57 ± 0.61 mm; LD, 3.11 ± 0.72 mm versus 2.80 ± 0.62 mm; Area 7.01 ± 3.28 mm2 versus 5.93 ± 2.66 mm2. The vessel-based discrepancy between 3D QCA and IVUS or OCT long diameters increased with increasing vessel curvature. In conclusion, our comparison of co-registered 3D QCA and invasive imaging data suggests a bias towards larger lumen dimensions by IVUS and by OCT, which was more pronounced in larger and tortuous vessels.
Collapse
|
104
|
Gupta V, Kirişli HA, Hendriks EA, van der Geest RJ, van de Giessen M, Niessen W, Reiber JHC, Lelieveldt BPF. Cardiac MR perfusion image processing techniques: a survey. Med Image Anal 2012; 16:767-85. [PMID: 22297264 DOI: 10.1016/j.media.2011.12.005] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2011] [Revised: 12/14/2011] [Accepted: 12/15/2011] [Indexed: 02/05/2023]
Abstract
First-pass cardiac MR perfusion (CMRP) imaging has undergone rapid technical advancements in recent years. Although the efficacy of CMRP imaging in the assessment of coronary artery diseases (CAD) has been proven, its clinical use is still limited. This limitation stems, in part, from manual interaction required to quantitatively analyze the large amount of data. This process is tedious, time-consuming, and prone to operator bias. Furthermore, acquisition and patient related image artifacts reduce the accuracy of quantitative perfusion assessment. With the advent of semi- and fully automatic image processing methods, not only the challenges posed by these artifacts have been overcome to a large extent, but a significant reduction has also been achieved in analysis time and operator bias. Despite an extensive literature on such image processing methods, to date, no survey has been performed to discuss this dynamic field. The purpose of this article is to provide an overview of the current state of the field with a categorical study, along with a future perspective on the clinical acceptance of image processing methods in the diagnosis of CAD.
Collapse
|
105
|
Huétink K, van 't Klooster R, Kaptein BL, Watt I, Kloppenburg M, Nelissen RGHH, Reiber JHC, Stoel BC. Automatic radiographic quantification of hand osteoarthritis; accuracy and sensitivity to change in joint space width in a phantom and cadaver study. Skeletal Radiol 2012; 41:41-9. [PMID: 21311883 PMCID: PMC3223586 DOI: 10.1007/s00256-011-1110-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/02/2010] [Revised: 01/06/2011] [Accepted: 01/18/2011] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To validate a newly developed quantification method that automatically detects and quantifies the joint space width (JSW) in hand radiographs. Repeatability, accuracy and sensitivity to changes in JSW were determined. The influence of joint location and joint shape on the measurements was tested. METHODS A mechanical micrometer set-up was developed to define and adjust the true JSW in an acrylic phantom joint and in human cadaver-derived phalangeal joints. Radiographic measurements of the JSW were compared to the true JSW. Repeatability, systematic error (accuracy) and sensitivity (defined as the smallest detectable difference (SDD)) were determined. The influence of joint position on the JSW measurement was assessed by varying the location of the acrylic phantom on the X-ray detector with respect to the X-ray beam and the influence of joint shape was determined by using morphologically different human cadaver joints. RESULTS The mean systematic error was 0.052 mm in the phantom joint and 0.210 mm in the cadaver experiment. In the phantom experiments, the repeatability was high (SDD = 0.028 mm), but differed slightly between joint locations (p = 0.046), and a change in JSW of 0.037 mm could be detected. Dependent of the joint shape in the cadaver hand, a change in JSW between 0.018 and 0.047 mm could be detected. CONCLUSIONS The automatic quantification method is sensitive to small changes in JSW. Considering the published data of JSW decline in the normal and osteoarthritic population, the first signs of OA progression with this method can be detected within 1 or 2 years.
Collapse
|
106
|
Tu S, Jing J, Holm NR, Onsea K, Zhang T, Adriaenssens T, Dubois C, Desmet W, Thuesen L, Chen Y, Reiber JHC. In vivo assessment of bifurcation optimal viewing angles and bifurcation angles by three-dimensional (3D) quantitative coronary angiography. Int J Cardiovasc Imaging 2011; 28:1617-25. [PMID: 22169957 PMCID: PMC3473185 DOI: 10.1007/s10554-011-9996-x] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/24/2011] [Accepted: 12/02/2011] [Indexed: 01/02/2023]
Abstract
Evaluation and stenting of coronary bifurcation lesions may benefit from optimal angiographic views. The anatomy-defined bifurcation optimal viewing angle (ABOVA) is characterized by having an orthogonal view of the bifurcation, such that overlap and foreshortening at the ostium are minimized. However, due to the mechanical constraints of the X-ray systems, certain deep angles cannot be reached by the C-arm. Therefore, second best or, so-called obtainable bifurcation optimal viewing angle (OBOVA) has to be used as an alternative. This study assessed the distributions of ABOVA and OBOVA using 3D quantitative coronary angiography in a typical patient population. In addition, the bifurcation angles in four main coronary bifurcations were assessed and compared. Patients with obstructive coronary bifurcation disease were included in this multicenter registry. A novel and validated 3D QCA software package was applied to reconstruct the bifurcations and to calculate the bifurcation angles in 3D. A list of optimal viewing angle candidates including ABOVA was also automatically proposed by the software. In a next step, the operator selected the best viewing angle as OBOVA, while applying a novel overlap prediction approach to assure no overlap between the target bifurcation and other major coronary arteries. A total of 194 bifurcations from 181 patients were assessed. The ABOVA could not be reached in 56.7% of the cases; being 40 (81.6%), 40 (78.4%), 9 (17.6%), and 21 (48.8%) cases for LM/LAD/LCx, LAD/Diagonal, LCx/OM, and PDA/PLA, respectively. Both ABOVA and OBOVA distributed sparsely with large ranges of variance: LM/LAD/LCx, 5 ± 33 RAO, 47 ± 35 Caudal versus 4 ± 39 LAO, 35 ± 16 Caudal; LAD/Diagonal, 4 ± 38 RAO, 50 ± 14 Cranial versus 14 ± 28 LAO, 33 ± 5 Cranial; LCx/OM, 21 ± 32 LAO, 27 ± 17 Caudal versus 18 ± 31 LAO, 25 ± 13 Caudal; PDA/PLA, 34 ± 21 LAO, 36 ± 21 Cranial versus 28 ± 25 LAO, 29 ± 15 Cranial. LM/LAD/LCx had the smallest proximal bifurcation angle (128° ± 24°) and the largest distal bifurcation angle (80° ± 21°), as compared with LAD/Diagonal (151° ± 13º and 48° ± 16º), LCx/OM (146° ± 18º and 57° ± 16°), and PDA/PLA (145° ± 19° and 59° ± 17°). In conclusion, large variabilities in optimal viewing angles existed for all main coronary bifurcations. The anatomy-defined bifurcation optimal viewing angle could not be reached in vivo in roughly half of the cases due to the mechanical constraints of the current X-ray systems. Obtainable bifurcation optimal viewing angle should be provided as an alternative or second best. The bifurcation angles in the left main bifurcation demonstrated the largest variabilities.
Collapse
|
107
|
Suinesiaputra A, de Koning PJH, Zudilova-Seinstra E, Reiber JHC, van der Geest RJ. Automated quantification of carotid artery stenosis on contrast-enhanced MRA data using a deformable vascular tube model. Int J Cardiovasc Imaging 2011; 28:1513-24. [PMID: 22160666 PMCID: PMC3463799 DOI: 10.1007/s10554-011-9988-x] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/19/2011] [Accepted: 11/24/2011] [Indexed: 12/12/2022]
Abstract
The purpose of this study was to develop and validate a method for automated segmentation of the carotid artery lumen from volumetric MR Angiographic (MRA) images using a deformable tubular 3D Non-Uniform Rational B-Splines (NURBS) model. A flexible 3D tubular NURBS model was designed to delineate the carotid arterial lumen. User interaction was allowed to guide the model by placement of forbidden areas. Contrast-enhanced MRA (CE-MRA) from 21 patients with carotid atherosclerotic disease were included in this study. The validation was performed against expert drawn contours on multi-planar reformatted image slices perpendicular to the artery. Excellent linear correlations were found on cross-sectional area measurement (r = 0.98, P < 0.05) and on luminal diameter (r = 0.98, P < 0.05). Strong match in terms of the Dice similarity indices were achieved: 0.95 ± 0.02 (common carotid artery), 0.90 ± 0.07 (internal carotid artery), 0.87 ± 0.07 (external carotid artery), 0.88 ± 0.09 (carotid bifurcation) and 0.75 ± 0.20 (stenosed segments). Slight overestimation of stenosis grading by the automated method was observed. The mean differences was 7.20% (SD = 21.00%) and 5.2% (SD = 21.96%) when validated against two observers. Reproducibility in stenosis grade calculation by the automated method was high; the mean difference between two repeated analyses was 1.9 ± 7.3%. In conclusion, the automated method shows high potential for clinical application in the analysis of CE-MRA of carotid arteries.
Collapse
|
108
|
van Velzen JE, de Graaf FR, de Graaf MA, Schuijf JD, Kroft LJ, de Roos A, Reiber JHC, Bax JJ, Jukema JW, Boersma E, Schalij MJ, van der Wall EE. Comprehensive assessment of spotty calcifications on computed tomography angiography: comparison to plaque characteristics on intravascular ultrasound with radiofrequency backscatter analysis. J Nucl Cardiol 2011; 18:893-903. [PMID: 21769702 PMCID: PMC3175045 DOI: 10.1007/s12350-011-9428-2] [Citation(s) in RCA: 74] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2011] [Accepted: 06/28/2011] [Indexed: 10/25/2022]
Abstract
BACKGROUND The purpose of the study was to systematically compare calcification patterns in plaques on computed tomography angiography (CTA) with plaque characteristics on intravascular ultrasound with radiofrequency backscatter analysis (IVUS-VH). METHODS AND RESULTS In total, 108 patients underwent CTA and IVUS-VH. On CTA, calcification patterns in plaques were classified as non-calcified, spotty or dense calcifications. Plaques with spotty calcifications were differentiated into small spotty (<1 mm), intermediate spotty (1-3 mm) and large spotty calcifications (≥3 mm). Plaque characteristics deemed more high-risk on IVUS-VH were defined by % necrotic core (NC) and presence of thin cap fibroatheroma (TCFA). Overall, 300 plaques were identified both on CTA and IVUS-VH. % NC core was significantly higher in plaques with small spotty calcifications as compared to non-calcified plaques (20% vs 13%, P = .006). In addition, there was a trend for a higher % NC in plaques with small spotty calcifications than in plaques with intermediate spotty calcifications (20% vs 14%, P = .053). Plaques with small spotty calcifications had the highest % TCFA as compared to large spotty and dense calcifications (31% vs 9% and 31% vs 6%, P < .05). CONCLUSION Plaques with small spotty calcifications on CTA were related to plaque characteristics deemed more high-risk on IVUS-VH. Therefore, CTA may be valuable in the assessment of the vulnerable plaque.
Collapse
|
109
|
Kirişli HA, Gupta V, Kirschbaum SW, Rossi A, Metz CT, Schaap M, van Geuns RJ, Mollet N, Lelieveldt BPF, Reiber JHC, van Walsum T, Niessen WJ. Comprehensive visualization of multimodal cardiac imaging data for assessment of coronary artery disease: first clinical results of the SMARTVis tool. Int J Comput Assist Radiol Surg 2011; 7:557-71. [PMID: 21948075 DOI: 10.1007/s11548-011-0657-2] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2011] [Accepted: 08/25/2011] [Indexed: 12/29/2022]
Abstract
PURPOSE In clinical practice, both coronary anatomy and myocardial perfusion information are needed to assess coronary artery disease (CAD). The extent and severity of coronary stenoses can be determined using computed tomography coronary angiography (CTCA); the presence and amount of ischemia can be identified using myocardial perfusion imaging, such as perfusion magnetic resonance imaging (PMR). To determine which specific stenosis is associated with which ischemic region, experts use assumptions on coronary perfusion territories. Due to the high variability between patient's coronary artery anatomies, as well as the uncertain relation between perfusion territories and supplying coronary arteries, patient-specific systems are needed. MATERIAL AND METHODS We present a patient-specific visualization system, called Synchronized Multimodal heART Visualization (SMARTVis), for relating coronary stenoses and perfusion deficits derived from CTCA and PMR, respectively. The system consists of the following comprehensive components: (1) two or three-dimensional fusion of anatomical and functional information, (2) automatic detection and ranking of coronary stenoses, (3) estimation of patient-specific coronary perfusion territories. RESULTS The potential benefits of the SMARTVis tool in assessing CAD were investigated through a case-study evaluation (conventional vs. SMARTVis tool): two experts analyzed four cases of patients with suspected multivessel coronary artery disease. When using the SMARTVis tool, a more reliable estimation of the relation between perfusion deficits and stenoses led to a more accurate diagnosis, as well as a better interobserver diagnosis agreement. CONCLUSION The SMARTVis comprehensive visualization system can be effectively used to assess disease status in multivessel CAD patients, offering valuable new options for the diagnosis and management of these patients.
Collapse
|
110
|
Prins AH, Kaptein BL, Stoel BC, Nelissen RGHH, Reiber JHC, Valstar ER. Integrated contour detection and pose estimation for fluoroscopic analysis of knee implants. Proc Inst Mech Eng H 2011; 225:753-61. [PMID: 21922952 DOI: 10.1177/0954411911407669] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
With fluoroscopic analysis of knee implant kinematics the implant contour must be detected in each image frame, followed by estimation of the implant pose. With a large number of possibly low-quality images, the contour detection is a time-consuming bottleneck. The present paper proposes an automated contour detection method, which is integrated in the pose estimation. In a phantom experiment the automated method was compared with a standard method, which uses manual selection of correct contour parts. Both methods demonstrated comparable precision, with a minor difference in the Y-position (0.08 mm versus 0.06 mm). The precision of each method was so small (below 0.2 mm and 0.3 degrees) that both are sufficiently accurate for clinical research purposes. The efficiency of both methods was assessed on six clinical datasets. With the automated method the observer spent 1.5 min per image, significantly less than 3.9 min with the standard method. A Bland-Altman analysis between the methods demonstrated no discernible trends in the relative femoral poses. The threefold increase in efficiency demonstrates that a pose estimation approach with integrated contour detection is more intuitive than a standard method. It eliminates most of the manual work in fluoroscopic analysis, with sufficient precision for clinical research purposes.
Collapse
|
111
|
Tao Q, Milles J, VAN Huls VAN Taxis C, Lamb HJ, Reiber JHC, Zeppenfeld K, VAN DER Geest RJ. Toward magnetic resonance-guided electroanatomical voltage mapping for catheter ablation of scar-related ventricular tachycardia: a comparison of registration methods. J Cardiovasc Electrophysiol 2011; 23:74-80. [PMID: 21914023 DOI: 10.1111/j.1540-8167.2011.02167.x] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
INTRODUCTION Integration of preprocedural delayed enhanced magnetic resonance imaging (DE-MRI) with electroanatomical voltage mapping (EAVM) may provide additional high-resolution substrate information for catheter ablation of scar-related ventricular tachycardias (VT). Accurate and fast image integration of DE-MRI with EAVM is desirable for MR-guided ablation. METHODS AND RESULTS Twenty-six VT patients with large transmural scar underwent catheter ablation and preprocedural DE-MRI. With different registration models and EAVM input, 3 image integration methods were evaluated and compared to the commercial registration module CartoMerge. The performance was evaluated both in terms of distance measure that describes surface matching, and correlation measure that describes actual scar correspondence. Compared to CartoMerge, the method that uses the translation-and-rotation model and high-density EAVM input resulted in a registration error of 4.32±0.69 mm as compared to 4.84 ± 1.07 (P <0.05); the method that uses the translation model and high-density EAVM input resulted in a registration error of 4.60 ± 0.65 mm (P = NS); and the method that uses the translation model and a single anatomical landmark input resulted in a registration error of 6.58 ± 1.63 mm (P < 0.05). No significant difference in scar correlation was observed between all 3 methods and CartoMerge (P = NS). CONCLUSIONS During VT ablation procedures, accurate integration of EAVM and DE-MRI can be achieved using a translation registration model and a single anatomical landmark. This model allows for image integration in minimal mapping time and is likely to reduce fluoroscopy time and increase procedure efficacy.
Collapse
|
112
|
van Ijsseldijk EA, Valstar ER, Stoel BC, Nelissen RGHH, Reiber JHC, Kaptein BL. The robustness and accuracy of in vivo linear wear measurements for knee prostheses based on model-based RSA. J Biomech 2011; 44:2724-7. [PMID: 21907991 DOI: 10.1016/j.jbiomech.2011.08.013] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2011] [Revised: 07/13/2011] [Accepted: 08/13/2011] [Indexed: 10/17/2022]
Abstract
Accurate in vivo measurements methods of wear in total knee arthroplasty are required for a timely detection of excessive wear and to assess new implant designs. Component separation measurements based on model-based Roentgen stereophotogrammetric analysis (RSA), in which 3-dimensional reconstruction methods are used, have shown promising results, yet the robustness of these measurements is unknown. In this study, the accuracy and robustness of this measurement for clinical usage was assessed. The validation experiments were conducted in an RSA setup with a phantom setup of a knee in a vertical orientation. 72 RSA images were created using different variables for knee orientations, two prosthesis types (fixed-bearing Duracon knee and fixed-bearing Triathlon knee) and accuracies of the reconstruction models. The measurement error was determined for absolute and relative measurements and the effect of knee positioning and true seperation distance was determined. The measurement method overestimated the separation distance with 0.1mm on average. The precision of the method was 0.10mm (2*SD) for the Duracon prosthesis and 0.20mm for the Triathlon prosthesis. A slight difference in error was found between the measurements with 0° and 10° anterior tilt. (difference=0.08mm, p=0.04). The accuracy of 0.1mm and precision of 0.2mm can be achieved for linear wear measurements based on model-based RSA, which is more than adequate for clinical applications. The measurement is robust in clinical settings. Although anterior tilt seems to influence the measurement, the size of this influence is low and clinically irrelevant.
Collapse
|
113
|
Mutsaerts HJMM, Palm-Meinders IH, de Craen AJM, Reiber JHC, Blauw GJ, van Buchem MA, van der Grond J, Box FMA. Diastolic carotid artery wall shear stress is associated with cerebral infarcts and periventricular white matter lesions. Stroke 2011; 42:3497-501. [PMID: 21903967 DOI: 10.1161/strokeaha.111.614453] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND AND PURPOSE Low wall shear stress (WSS) is an early marker in the development of vascular lesions. The present study aims to assess the relationship between diastolic and systolic WSS in the internal carotid artery and periventricular (PWML), deep white matter lesions, and cerebral infarcts (CI). METHODS Early, mid, and late diastolic and peak systolic WSS were derived from shear rate obtained by gradient echo phase contrast magnetic resonance sequences multiplied by individually modeled viscosity. PWML, deep white matter lesions, and CI were derived from proton density (PD), T2, and fluid attenuated inversion recovery (FLAIR) MRI in 329 participants (70-82 years; PROSPER baseline). Analyses were adjusted, if appropriate, for age, gender, intracranial volume, and multiple cardiovascular risk factors. RESULTS Mid-diastolic WSS was significantly correlated with the presence of PWML (B=-10.15; P=0.006) and CI (B=-2.06; P=0.044), but not with deep white matter lesions (B=-1.30; P=0.050; adjusted for age, gender, WML, and intracranial volume). After adjustment for cardiovascular risk factors, these correlations weakened but remained significant. Systolic WSS was not correlated with any of the cerebrovascular parameters. CONCLUSIONS This study is the first to our knowledge to present a cross-sectional correlation between carotid artery WSS and cerebrovascular pathology such as PWML and CI in a large population. Furthermore, it shows that diastolic hemodynamics may be more important than systolic or mean hemodynamics. Future studies exploring vascular hemodynamic damage should focus on diastolic WSS.
Collapse
|
114
|
Tu S, Hao P, Koning G, Wei X, Song X, Chen A, Reiber JHC. In vivo assessment of optimal viewing angles from X-ray coronary angiography. EUROINTERVENTION 2011; 7:112-20. [PMID: 21550911 DOI: 10.4244/eijv7i1a19] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
AIMS To propose and validate a novel approach to determine the optimal angiographic viewing angles for a selected coronary (target) segment from X-ray coronary angiography, without the need to reconstruct the entire coronary tree in three-dimensions (3D), such that subsequent interventions are carried out from the best view. METHODS AND RESULTS The approach starts with standard quantitative coronary angiography (QCA) of the target vessel in two angiographic views. Next, the target vessel is reconstructed in 3D, and in a very simple and intuitive manner, the possible overlap of the target vessel and other vessel segments can be assessed, resulting in the best view with minimum foreshortening and overlap. A retrospective study including 67 patients was set up for the validation. The overlap prediction result was compared with the true overlap on the available angiographic views (TEST views). The foreshortening for the views proposed by the new approach software viewing angle (SVA) and the views used during the stent deployment software viewing angle (EVA) were compared. Two experienced interventional cardiologists visually evaluated the success of SVA with respect to EVA. The evaluation results were graded into five values ranging from -2 to 2. The overlap prediction algorithm successfully predicted the overlap condition for all 235 TEST views. EVA was associated with more foreshortening than SVA (8.9% ± 8.2% vs. 1.6% ± 1.5%, p<0.001). The average evaluated point for the success of SVA was 0.94 ± 0.80 (p <0.001), indicating that the evaluators were in favor of the optimal views determined by the proposed approach versus the views used during the actual intervention. CONCLUSIONS The proposed approach is able to accurately and quickly determine the optimal viewing angles for the online support of coronary interventions.
Collapse
|
115
|
Tu S, Holm NR, Koning G, Maeng M, Reiber JHC. The impact of acquisition angle differences on three-dimensional quantitative coronary angiography. Catheter Cardiovasc Interv 2011; 78:214-22. [PMID: 21766427 DOI: 10.1002/ccd.23047] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/30/2010] [Revised: 02/01/2011] [Accepted: 02/13/2011] [Indexed: 11/10/2022]
Abstract
BACKGROUND Three-dimensional (3D) quantitative coronary angiography (QCA) requires two angiographic views to restore vessel dimensions. This study investigated the impact of acquisition angle differences (AADs) of the two angiographic views on the assessed dimensions by 3D QCA. METHODS X-ray angiograms of an assembled brass phantom with different types of straight lesions were recorded at multiple angiographic projections. The projections were randomly matched as pairs and 3D QCA was performed in those pairs with AAD larger than 25°. The lesion length and diameter stenosis in three different lesions, a circular concentric severe lesion (A), a circular concentric moderate lesion (B), and a circular eccentric moderate lesion (C), were measured by 3D QCA. The acquisition protocol was repeated for a silicone bifurcation phantom, and the bifurcation angles and bifurcation core volume were measured by 3D QCA. The measurements were compared with the true dimensions if applicable and their correlation with AAD was studied. RESULTS 50 matched pairs of angiographic views were analyzed for the brass phantom. The average value of AAD was 48.0 ± 14.1°. The percent diameter stenosis was slightly overestimated by 3D QCA for all lesions: A (error 1.2 ± 0.9%, P < 0.001); B (error 0.6 ± 0.5%, P < 0.001); C (error 1.1 ± 0.6%, P < 0.001). The correlation of the measurements with AAD was only significant for lesion A (R(2) = 0.151, P = 0.005). The lesion length was slightly overestimated by 3D QCA for lesion A (error 0.06 ± 0.18 mm, P = 0.026), but well assessed for lesion B (error -0.00 ± 0.16 mm, P = 0.950) and lesion C (error -0.01 ± 0.18 mm, P = 0.585). The correlation of the measurements with AAD was not significant for any lesion. Forty matched pairs of angiographic views were analyzed for the bifurcation phantom. The average value of AAD was 49.1 ± 15.4°. 3D QCA slightly overestimated the proximal angle (error 0.4 ± 1.1°, P = 0.046) and the distal angle (error 1.5 ± 1.3°, P < 0.001). The correlation with AAD was only significant for the distal angle (R(2) = 0.256, P = 0.001). The correlation of bifurcation core volume measurements with AAD was not significant (P = 0.750). Of the two aforementioned measurements with significant correlation with AAD, the errors tended to increase as AAD became larger. CONCLUSIONS 3D QCA can be used to reliably assess vessel dimensions and bifurcation angles. Increasing the AAD of the two angiographic views does not increase accuracy and precision of 3D QCA for circular lesions or bifurcation dimensions.
Collapse
|
116
|
de Graaf FR, van Velzen JE, Witkowska AJ, Schuijf JD, van der Bijl N, Kroft LJ, de Roos A, Reiber JHC, Bax JJ, de Grooth GJ, Jukema JW, van der Wall EE. Diagnostic performance of 320-slice multidetector computed tomography coronary angiography in patients after coronary artery bypass grafting. Eur Radiol 2011; 21:2285-96. [PMID: 21735068 PMCID: PMC3184392 DOI: 10.1007/s00330-011-2192-5] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2011] [Revised: 05/05/2011] [Accepted: 05/12/2011] [Indexed: 11/15/2022]
Abstract
Objectives To evaluate the diagnostic performance of 320-slice computed tomography coronary angiography (CTA) in the evaluation of patients with prior coronary artery bypass grafting (CABG). Invasive coronary angiography (ICA) served as the standard of reference, using a quantitative approach. Methods CTA studies were performed using CT equipment with 320 detector-rows, each 0.5 mm wide, and a gantry rotation time of 0.35 s. All grafts, recipient and nongrafted vessels were deemed interpretable or uninterpretable. The presence of significant (≥50%) stenosis and occlusion were determined on vessel and patient basis. Results were compared to ICA using quantitative coronary angiography. Results A total of 40 patients (28 men, 76 ± 15 years), with 89 grafts, were included in the study. On a graft analysis, the sensitivity, specificity, positive and negative predictive values in the evaluation of significant stenosis were 96%, 92%, 83% and 98% respectively. The diagnostic accuracy for the assessment of recipient and nongrafted vessels was 89% and 80%, respectively. The diagnostic accuracy for the assessment of graft, recipient and nongrafted vessel occlusion was 96%, 92% and 100%, respectively. Conclusions 320-slice CTA allows accurate non-invasive assessment of significant graft, recipient vessel and nongrafted vessel stenosis in patients with prior CABG.
Collapse
|
117
|
de Jong LW, Ferrarini L, van der Grond J, Milles JR, Reiber JHC, Westendorp RGJ, Bollen ELEM, Middelkoop HAM, van Buchem MA. Shape abnormalities of the striatum in Alzheimer's disease. J Alzheimers Dis 2011; 23:49-59. [PMID: 20930298 DOI: 10.3233/jad-2010-101026] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Postmortem studies show pathological changes in the striatum in Alzheimer's disease (AD). Here, we examine the surface of the striatum in AD and assess whether changes of the surface are associated with impaired cognitive functioning. The shape of the striatum (n. accumbens, caudate nucleus, and putamen) was compared between 35 AD patients and 35 individuals without cognitive impairment. The striatum was automatically segmented from 3D T1 magnetic resonance images and automatic shape modeling tools (Growing Adaptive Meshes) were applied for morphometrical analysis. Repeated permutation tests were used to identify locations of consistent shape deformities of the striatal surface in AD. Linear regression models, corrected for age, gender, educational level, head size, and total brain parenchymal volume were used to assess the relation between cognitive performance and local surface deformities. In AD patients, differences of shape were observed on the medial head of the caudate nucleus and on the ventral lateral putamen, but not on the accumbens. The head of the caudate nucleus and ventral lateral putamen are characterized by extensive connections with the orbitofrontal and medial temporal cortices. Severity of cognitive impairment was associated with the degree of deformity of the surfaces of the accumbens, rostral medial caudate nucleus, and ventral lateral putamen. These findings provide evidence for the hypothesis that in AD primarily associative and limbic cerebral networks are affected.
Collapse
|
118
|
Stoel BC, Dirksen A, Stockley RA, Parr D, Piitulainen E, Shaker SB, Russi EW, Bakker ME, Reiber JHC, Stolk J. Eureka? Radiology 2011; 259:610-1; author reply 611-2. [PMID: 21502395 DOI: 10.1148/radiol.11102262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
119
|
Tuinenburg JC, Koning G, Reiber JHC. Quantitative Coronary and Vascular Angiography. Interv Cardiol 2011. [DOI: 10.1002/9781444319446.ch7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
|
120
|
|
121
|
Costa RA, Reiber JHC, Rybicki FJ, Schoenhagen P, Stillman AA, de Sutter J, van de Veire NRL, van der Wall EE. Cardiovascular imaging 2010 in the International Journal of Cardiovascular Imaging. Int J Cardiovasc Imaging 2011; 27:309-19. [PMID: 21347592 PMCID: PMC3092067 DOI: 10.1007/s10554-011-9834-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/07/2011] [Accepted: 02/08/2011] [Indexed: 01/20/2023]
|
122
|
Reiber JHC. Introduction to QCA, IVUS and OCT in interventional cardiology. Int J Cardiovasc Imaging 2011; 27:153-4. [PMID: 21337024 PMCID: PMC3078306 DOI: 10.1007/s10554-011-9808-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/10/2011] [Accepted: 01/13/2011] [Indexed: 11/24/2022]
|
123
|
Ferrarini L, Veer IM, van Lew B, Oei NYL, van Buchem MA, Reiber JHC, Rombouts SARB, Milles J. Non-parametric model selection for subject-specific topological organization of resting-state functional connectivity. Neuroimage 2011; 56:1453-62. [PMID: 21338693 DOI: 10.1016/j.neuroimage.2011.02.028] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2010] [Revised: 02/04/2011] [Accepted: 02/09/2011] [Indexed: 11/30/2022] Open
Abstract
In recent years, graph theory has been successfully applied to study functional and anatomical connectivity networks in the human brain. Most of these networks have shown small-world topological characteristics: high efficiency in long distance communication between nodes, combined with highly interconnected local clusters of nodes. Moreover, functional studies performed at high resolutions have presented convincing evidence that resting-state functional connectivity networks exhibits (exponentially truncated) scale-free behavior. Such evidence, however, was mostly presented qualitatively, in terms of linear regressions of the degree distributions on log-log plots. Even when quantitative measures were given, these were usually limited to the r(2) correlation coefficient. However, the r(2) statistic is not an optimal estimator of explained variance, when dealing with (truncated) power-law models. Recent developments in statistics have introduced new non-parametric approaches, based on the Kolmogorov-Smirnov test, for the problem of model selection. In this work, we have built on this idea to statistically tackle the issue of model selection for the degree distribution of functional connectivity at rest. The analysis, performed at voxel level and in a subject-specific fashion, confirmed the superiority of a truncated power-law model, showing high consistency across subjects. Moreover, the most highly connected voxels were found to be consistently part of the default mode network. Our results provide statistically sound support to the evidence previously presented in literature for a truncated power-law model of resting-state functional connectivity.
Collapse
|
124
|
Tuinenburg JC, Koning G, Rareş A, Janssen JP, Lansky AJ, Reiber JHC. Dedicated bifurcation analysis: basic principles. Int J Cardiovasc Imaging 2011; 27:167-74. [PMID: 21327913 PMCID: PMC3078323 DOI: 10.1007/s10554-010-9795-9] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/24/2010] [Accepted: 12/30/2010] [Indexed: 11/25/2022]
Abstract
Over the last several years significant interest has arisen in bifurcation stenting, in particular stimulated by the European Bifurcation Club. Traditional straight vessel analysis by QCA does not satisfy the requirements for such complex morphologies anymore. To come up with practical solutions, we have developed two models, a Y-shape and a T-shape model, suitable for bifurcation QCA analysis depending on the specific anatomy of the coronary bifurcation. The principles of these models are described in this paper, as well as the results of validation studies carried out on clinical materials. It can be concluded that the accuracy, precision and applicability of these new bifurcation analyses are conform the general guidelines that have been set many years ago for conventional QCA-analyses.
Collapse
|
125
|
Tu S, Holm NR, Koning G, Huang Z, Reiber JHC. Fusion of 3D QCA and IVUS/OCT. Int J Cardiovasc Imaging 2011; 27:197-207. [PMID: 21264684 PMCID: PMC3078305 DOI: 10.1007/s10554-011-9809-2] [Citation(s) in RCA: 60] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/12/2011] [Accepted: 01/13/2011] [Indexed: 11/30/2022]
Abstract
The combination/fusion of quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS)/optical coherence tomography (OCT) depends to a great extend on the co-registration of X-ray angiography (XA) and IVUS/OCT. In this work a new and robust three-dimensional (3D) segmentation and registration approach is presented and validated. The approach starts with standard QCA of the vessel of interest in the two angiographic views (either biplane or two monoplane views). Next, the vessel of interest is reconstructed in 3D and registered with the corresponding IVUS/OCT pullback series by a distance mapping algorithm. The accuracy of the registration was retrospectively evaluated on 12 silicone phantoms with coronary stents implanted, and on 24 patients who underwent both coronary angiography and IVUS examinations of the left anterior descending artery. Stent borders or sidebranches were used as markers for the validation. While the most proximal marker was set as the baseline position for the distance mapping algorithm, the subsequent markers were used to evaluate the registration error. The correlation between the registration error and the distance from the evaluated marker to the baseline position was analyzed. The XA-IVUS registration error for the 12 phantoms was 0.03 ± 0.32 mm (P = 0.75). One OCT pullback series was excluded from the phantom study, since it did not cover the distal stent border. The XA-OCT registration error for the remaining 11 phantoms was 0.05 ± 0.25 mm (P = 0.49). For the in vivo validation, two patients were excluded due to insufficient image quality for the analysis. In total 78 sidebranches were identified from the remaining 22 patients and the registration error was evaluated on 56 markers. The registration error was 0.03 ± 0.45 mm (P = 0.67). The error was not correlated to the distance between the evaluated marker and the baseline position (P = 0.73). In conclusion, the new XA-IVUS/OCT co-registration approach is a straightforward and reliable solution to combine X-ray angiography and IVUS/OCT imaging for the assessment of the extent of coronary artery disease. It provides the interventional cardiologist with detailed information about vessel size and plaque size at every position along the vessel of interest, making this a suitable tool during the actual intervention.
Collapse
|