101
|
Dhakhwa R, Sapkota S, Maharjan A, Pradhan S. Malignant Serous Effusions among Hospital In-patients in a Tertiary Care Hospital: A Descriptive Cross-sectional Study. JNMA J Nepal Med Assoc 2022; 60:167-170. [PMID: 35210637 PMCID: PMC9200016 DOI: 10.31729/jnma.7145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2021] [Accepted: 02/15/2022] [Indexed: 11/21/2022] Open
Abstract
Introduction: Cell block technique is an adjunct to conventional smears in the diagnosis of malignancy in effusion fluid. It aims at retrieving cellular material and concentrating cells in a small field, with preservation of cytomorphologic details. The objective of this study was to find the proportion of malignant serous effusions using cell block technique among hospital in-patients in a tertiary care centre. Methods: This was a descriptive cross-sectional study conducted among patients visiting a tertiary care centre between 1st June 2020 to 30th November 2020. Ethical approval was taken from the Institutional Review Committee (Reference number: 305202001). Using a convenience sampling method, 96 hospital in-patients were included in the study. Serous effusions were evaluated by conventional smears and cell block sections. Data was analysed using the Statistical Package for the Social Sciences version 23. Point estimate at 95% Confidence Interval was calculated along with frequency, percentage, mean and standard deviation. Results: Among 96 hospital in-patients, 15 (15.62%) (8.35-22.88 at 95% Confidence Interval) were diagnosed as positive for malignancy by using cell block technique. By conventional smears, 80 (83.33%) cases turned out to be negative for malignancy, 13 (13.54%) were positive for malignancy and three (3.12%) were suspicious for malignancy. Of the three (3.12%) cases suspected for malignancy, two turned out to be positive for malignancy and one was found to be negative for malignancy on cell block technology. Conclusions: The proportion of malignant serous effusions was similar in comparison to other studies. Cell block technique could be routinely incorporated along with conventional smears for a more accurate diagnosis of malignancy on serous effusion.
Collapse
|
102
|
Uzun E, Erkilic S. Diagnostic accuracy of Thinprep® in cervical lymph node aspiration: Assessment according to the Sydney system. Diagn Cytopathol 2022; 50:253-262. [PMID: 35148033 DOI: 10.1002/dc.24943] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2021] [Revised: 01/20/2022] [Accepted: 01/26/2022] [Indexed: 11/07/2022]
Abstract
BACKGROUND Fine-needle aspiration cytology (FNAC) is a reliable technique that has been used for many years in lymphadenopathy diagnosis. Although conventional smear is the standard approach in FNAC, liquid-based cytology (LBC) is accepted as an alternative method. Reporting standardization is a significant gap in fine-needle aspiration cytology, leading to failure in pathologist-clinician dialog and interobserver variability. In 2020, an expert panel proposed the Sydney system for classifying and reporting lymph node aspiration cytology. This study aimed to evaluate the diagnostic accuracy of LBC in lymph node aspiration cytology under the guidance of the Sydney system. METHODS Five hundred-four LBC samples were reevaluated and classified according to the Sydney system. Of these, n = 24 were categorized as L1-inadequate/non-diagnostic, n = 283 as L2-benign, n = 36 as L3- atypical cells of undetermined significance/atypical lymphoid cells of uncertain significance (AUS/ALUS), n = 48 as L4-suspicious, and n = 113 as L5-malignant. Four hundred-one samples were histopathologically confirmed. The diagnostic accuracy of LBC and the risk of malignancy for each Sydney category were calculated. RESULTS The results were as follows: sensitivity 98.97%; specificity 98.60%; positive predictive value 94.80%; negative predictive value 99.29%; and overall diagnostic accuracy 98.75%. The ROM was 16.6% for L1, 0.7% for L2, 88.8% for L3, and 100% for L4 and L5. CONCLUSION LBC is suitable for use in lymph node aspiration under the guidance of the Sydney system and has high diagnostic accuracy. Future comprehensive studies will increase the applicability of the Sydney system and minimize interobserver variability.
Collapse
|
103
|
Kurtulan O, Bilginer B, Soylemezoglu F. Challenges in the Intraoperative Consultation of Low-Grade Epilepsy-Associated Neuroepithelial Tumors by Cytomorphology in Squash Preparations. Acta Cytol 2022; 66:142-148. [PMID: 35016169 DOI: 10.1159/000521249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2021] [Accepted: 11/28/2021] [Indexed: 11/19/2022]
Abstract
INTRODUCTION Low-grade epilepsy-associated neuroepithelial tumors (LEATs) create a diagnostic challenge in daily practice and intraoperative pathological consultation (IC) in particular. Squash smears are extremely useful in IC for accurate diagnosis; however, the knowledge on cytopathologic features of LEATs is based on individual case reports. Here, we discuss the 3 most common and well-established entities of LEATs: ganglioglioma (GG), dysembryoplastic neuroepithelial tumor (DNT), and papillary glioneuronal tumor (PGNT). METHODS Thirty patients who underwent surgery for GG, DNT, and PGNT between 2001 and 2021 were collected. Squash smears prepared during intraoperative consultation were reviewed by 1 cytopathologist and an experienced neuropathologist. RESULTS Among the 30 tumors, 16 (53.3%) were GG, 11 (36.6%) DNT, and 3 (10%) PGNT. Cytomorphologically, all of the 3 tumor types share 2 common features such as dual cell population and vasculocentric pattern. GG smears were characteristically composed of dysplastic ganglion cells and piloid-like astrocytes on a complex architectural background of thin- to thick-walled vessels. DNT, on the other hand, showed oligodendroglial-like cells in a myxoid thin fibrillary background associated with a delicate capillary network. Common cytological features of PGNT were hyperchromatic cells with narrow cytoplasm surrounding hyalinized vessels forming a pseudopapillary pattern and bland cells with neuroendocrine nuclei dispersed in a neuropil background. CONCLUSION A higher diagnostic accuracy can be obtained when squash smears are applied with frozen sections. However, it is important to integrate clinical and radiologic features of the patient as well as to know the cytopathologic features of the LEAT spectrum in the context of differential diagnosis to prevent misinterpretation in the IC.
Collapse
|
104
|
Phruttinarakorn B, Plumworasawat S, Kayankarnnavee J, Lualon J, Pongtippan A. Application of the Paris Reporting System for Urine Cytology: The Three-Year Experience of a Single Tertiary Care Institute in Thailand. Acta Cytol 2022; 66:134-141. [PMID: 34999581 DOI: 10.1159/000521139] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Accepted: 11/22/2021] [Indexed: 11/19/2022]
Abstract
INTRODUCTION Urothelial carcinoma is one of the most common human cancers, both in Thailand and worldwide. Urine cytology is a screening tool used to detect urothelial carcinoma. The Paris System for Reporting Urinary Cytology (TPSRUC) was first published in 2016 to standardize the procedures, reporting, and management of urothelial carcinoma. Diagnostic categories include negative for high-grade urothelial carcinoma (NHGUC), atypical urothelial cells (AUCs), suspicious for HGUC (SHGUC), HGUC, low-grade urothelial neoplasm, and other malignancies. MATERIAL AND METHODS In a retrospective review, urine cytology specimens from 2016 to 2019 were reevaluated using the TPSRUC. The risk of high-grade malignant neoplasm (ROHM) for each diagnostic category was calculated. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of prediction of high-grade malignant neoplasms were evaluated for cases with histological follow-up specimens. RESULTS In total, 2,178 urine cytology specimens were evaluated, of which 456 cases had follow-up histological specimens. The ROHM in each diagnostic category was as follows: NHGUC, 17.4%; AUC, 49.9%; SHGUC, 81.2%; HGUC, 91.3%; and other malignant neoplasms, 87.5%. The sensitivity, specificity, PPV, NPV, and accuracy for high-grade malignant neoplasm prediction were 63%, 92.8%, 89%, 73.1%, and 78.5% when AUC was included as malignant in the comparison and 82.6%, 74.7%, 75.1%, 82.3%, and 78.5% when AUC was not considered malignant. CONCLUSIONS TPSRUC provides reliable results that are reproducible by different interpreters and is a helpful tool for the detection of HGUC.
Collapse
|
105
|
Meel M, Sahu I, Kumar M. Micronucleus scoring in breast cytology as a diagnostic tool to assess genotoxic changes. INDIAN J PATHOL MICR 2022; 65:223-225. [PMID: 35075007 DOI: 10.4103/ijpm.ijpm_1019_19] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/14/2023] Open
|
106
|
Mohanty P, Sahoo N, Lenka A, Bhattacharyya S. Unusual presentation of Langerhans cell sarcoma as bilateral submandibular gland swelling - A rare case report. Indian J Cancer 2022; 59:123-127. [PMID: 35645054 DOI: 10.4103/ijc.ijc_819_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Langerhans cell sarcoma (LCS) is a rare malignant tumor of Langerhans cells and uncommonly involves head and neck regions. Unlike Langerhans cell histiocytosis (LCH), it has an aggressive clinical course with malignant cytological features. Till now, a handful of cases have been reported and the common anatomical sites involved are skin, lymph node, and bone in loco - regional cases and lymph node, lung, liver, spleen, and bone in disseminated disease. Due to its rarity, standard protocols of treatment for these patients are not yet well established. Herein, we report such a case in a 25-year-old male presenting with a bilateral submandibular swelling, which was diagnosed as LCH on Fine Needle Aspiration Cytology (FNAC) and later confirmed to be a case of LCS in histopathological examination and immunohistochemistry. The authors are aware of only a single similar case being reported in the English literature.
Collapse
|
107
|
Baykus N, Özekinci S, Erdem ZB, Vurgun E, Yildiz FR. Comparison of Morphological Similarities and Differences between Liquid-Based Cytology and Conventional Techniques of Serous Effusion Cytology Specimens. Acta Cytol 2021; 66:159-164. [PMID: 34969029 DOI: 10.1159/000521052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2021] [Accepted: 11/14/2021] [Indexed: 11/19/2022]
Abstract
INTRODUCTION The aim of this study is to discover a fast and efficient method for the diagnosis of serous effusion cytology specimens by comparing the cytomorphological features of SurePath (SP) smears and smears prepared by cytospin. After the macroscopic features of the incoming material were recorded, it was divided into 2 for conventional technique (CT) and liquid-based technique. Cytospin was used for CT and SurePath for liquid-based technique in this study. MATERIALS AND METHODS 243 serous effusions (33 thoracentesis and 92 paracentesis fluids, 118 peritoneal lavage fluids) were investigated. After shaking the effusion gently, it was centrifuged for 5 min at 1,250 rpm for cytospin smear. SP smear was prepared according to the "BD PrepStain slide processor". Two smears were prepared with these 2 methods and then stained with Papanicolaou. The smears were examined under a light microscope in terms of fixation, background, cellularity, nucleus, and structural features. All statistical analysis of the data was performed using the SPSS 17.0 software. For each microscopic feature, the χ2 test was used to assess the significance of the relationship between cytospin and SP, and level of agreement in between the methods was assessed using the kappa statistic. RESULTS A statistically significant difference was observed between the 2 methods in background (p < 0.001), cellularity (p < 0.001), nucleus features (p < 0.001), and structural features (p < 0.05). There was no significant difference in fixation. Low level of agreement was observed with the kappa statistic in fixation, background, and cellularity. Moderate level of agreement was observed in the nucleus and structural feature groups with the kappa statistic. DISCUSSION/CONCLUSION Although there are advantages of liquid-based technique such as standardized fixation and cleaner background, since the cellular and background components required for morphological analysis and diagnosis are better preserved in cytospin, it is considered to be better to use liquid-based technique not alone but together with CT.
Collapse
|
108
|
Husaiyin S, Jiao Z, Yimamu K, Maisaidi R, Han L, Niyazi M. ThinPrep cytology combined with HPV detection in the diagnosis of cervical lesions in 1622 patients. PLoS One 2021; 16:e0260915. [PMID: 34855928 PMCID: PMC8638999 DOI: 10.1371/journal.pone.0260915] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2020] [Accepted: 11/19/2021] [Indexed: 11/18/2022] Open
Abstract
The timely detection of precancerous lesions and early intervention can greatly reduce cervical cancer occurrence. The current study aimed to assess the diagnostic value and accuracy of different methods of cervical lesion screening. A total of 1622 females who visited the Outpatient Department of Xinjiang Uyghur Autonomous Region People’s Hospital between January and December 2018 were consecutively enrolled. All participants underwent separate high-risk human papilloma virus (HR-HPV) DNA detection, ThinPrep cytology testing (TCT) and colposcopic biopsy. Their medical records were retrospectively analyzed. While considering biopsy outcomes as the gold standard, the diagnostic values of TCT, HR-HPV testing, and TCT+HR-HPV testing for cervical cancer screening were compared. The sensitivity, specificity and Youden index of each method were calculated. Among the different methods, TCT+HR-HPV testing had the highest sensitivity (89.8%), followed by TCT (79.9%) and HR-HPV testing (49.2%). The combined method also had the highest Youden value, and its screening outcomes exhibited the highest consistency with those of biopsy. In addition, the combined method had the largest area under the receiver operating characteristic (ROC) curve, which was 0.673 (0.647, 0.699), compared with any other screening method. Compared with TCT or HR-HPV testing alone, TCT+HR-HPV testing serves as a better screening method for cervical cancer and precancerous lesions.
Collapse
|
109
|
Haaga E, Kalfert D, Ludvíková M, Kholová I. Non-Invasive Follicular Thyroid Neoplasm with Papillary-Like Nuclear Features Is Not a Cytological Diagnosis, but It Influences Cytological Diagnosis Outcomes: A Systematic Review and Meta-Analysis. Acta Cytol 2021; 66:85-105. [PMID: 34781293 DOI: 10.1159/000519757] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Accepted: 09/16/2021] [Indexed: 12/19/2022]
Abstract
BACKGROUND A low-risk thyroid tumour, non-invasive follicular thyroid neoplasm with papillary-like nuclear features (NIFTP) was introduced in 2016. NIFTP criteria require a thorough histological examination to rule out capsular and lymphovascular invasion, which denies the possibility of preoperative cytological diagnosis. Nevertheless, since the adoption of the new entity, the cytology of NIFTP has been a subject of interest. OBJECTIVES The present systematic review and meta-analysis investigate the cytological diagnosis of NIFTP. METHOD An online PubMed literature search was conducted between March 1, 2020, and June 30, 2020, for all original articles considering the cytology of histologically proven NIFTP. The studies including data on fine needle aspiration specimens classified by The Bethesda System for Reporting Thyroid Cytology (TBSRTC) categories, risk of malignancy (ROMs) in the TBSRTC categories, and cytomorphological features of NIFTP were included in the meta-analysis. Non-English studies and case reports were excluded. The data were tabulated and statistical analysis was performed with Open Meta-Analyst program. RESULTS Fifty-eight studies with a total of 2,553 NIFTP cases were included in the study. The pooled prevalence of NIFTP cases was calculated among 25,892 surgically resected cases from 20 studies and the results show that NIFTP consisted 4.4% (95% confidence interval [CI]: 3.5-5.4%) of all cases. Most of the NIFTP cases (79.0%) belonged to the intermediate categories of TBSRTC. The pooled distribution of NIFTP cases in each TBSRTC category was 1.3% (95% CI: 0.8-1.7%) in non-diagnostic (ND), 8.9% (95% CI: 6.9-10.8%) in benign, 29.2% (95% CI: 25.0-33.4%) in atypia of undetermined significance or follicular lesion of undetermined significance (AUS/FLUS), 24.2% (95% CI: 19.6-28.9%) in follicular neoplasm (FN), 19.5% (95% CI: 16.1-22.9%) in suspicious for malignancy (SM), and 6.9% (95% CI: 5.2-8.7%) in malignant. Compared to pre-NIFTP era, the pooled risk differences of ROM were reduced by 2.4% in ND, 2.7% in benign, 8.2% in AUS/FLUS, 8.2% in FN, 7.3% in SM, and 1.1% in the malignant category. The cytomorphological features of NIFTP were similar to follicular variant of papillary thyroid carcinoma (FVPTC) but lesser to papillary thyroid carcinoma (PTC). CONCLUSIONS Based on our results, NIFTP remains a histological diagnosis. Although cytomorphological features cannot be used in differentiating NIFTP from FVPTC, they may guide in separating NIFTP from PTC. Features such as papillae, microfollicles, giant cells, psammoma bodies, and the amount of papillary-like nuclear features should be taken into account when suspicious of NIFTP. NIFTP should not have papillae or psammoma bodies, and giant cells were rarely observed.
Collapse
|
110
|
Shimura H, Matsuzuka T, Suzuki S, Iwadate M, Suzuki S, Yokoya S, Ohira T, Yasumura S, Suzuki S, Ohto H, Kamiya K. Fine Needle Aspiration Cytology Implementation and Malignancy Rates in Children and Adolescents Based on Japanese Guidelines: The Fukushima Health Management Survey. Thyroid 2021; 31:1683-1692. [PMID: 34762538 DOI: 10.1089/thy.2021.0072] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Background: The thyroid ultrasound examination (TUE) program was initiated among the residents of Fukushima Prefecture aged ≤18 years at the time of the Fukushima Dai-ichi Nuclear Power Plant accident. In this program, fine needle aspiration cytology (FNAC) was performed only in cases that conformed to the Japanese guidelines for the management of thyroid nodules. To analyze the suitability of the protocol in the TUE, we analyzed the implementation rate of FNAC and the detection rate of thyroid malignancy. Methods: There were 299,939 and 269,659 voluntary participants in the Preliminarily Baseline Survey (PLBS), first-round survey, and the first Full-scale Survey (FSS), second-round survey, of the TUE, respectively. FNAC is recommended for nodules with diameters 5.1-10.0 mm showing sonographic characteristics that are strongly suspicious for thyroid carcinoma; diameters 10.1-20.0 mm with characteristics that are suspicious for carcinoma; and all nodules with diameters >20 mm. Results: In the PLBS and the first FSS, 1362 and 1382 cases with thyroid nodules sized ≥5.1 mm in diameter were found, respectively. The implementation rates of FNAC in the PLBS were 20.1%, 63.2%, and 87.7% of subjects with nodules sized 5.1-10.0, 10.1-20.0, and ≥20.1 mm in diameter, respectively. In the first FSS, the FNAC implementation rates were 7.3%, 26.0%, and 50.0% in the subjects with nodules with diameters 5.1-10.0, 10.1-20.0, and ≥20.1 mm, respectively. In the subjects who underwent FNAC, the detection rates of malignant and suspected malignant nodules were 21.4% and 34.1% in the PLBS and first FSS, respectively. In the first FSS, malignant or suspected malignant nodules were found in 0.63% and 0.40% of subjects who had nodules of diameters ≤5.0 mm and 5.1-10.0 mm in the PLBS, respectively. In contrast, in the subjects with nodules measuring ≥10.0 mm in diameter in the PLBS, no malignancies were detected. Conclusions: The use of a protocol that conformed to the Japanese guidelines led to a reduction in the FNAC implementation rate and an increase in the malignancy detection rate in smaller nodules. In addition, the use of this strategy enabled us to avoid detection failure of thyroid carcinomas >10.0 mm.
Collapse
|
111
|
Gupta S, Gautam U, Susheilia S, Bansal B, Uppal R, Srinivasan R. Sodium Alginate versus Plasma Thrombin Cell Blocks in Diagnostic Cytopathology: A Comparative Analysis. Acta Cytol 2021; 66:72-78. [PMID: 34718240 DOI: 10.1159/000519336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Accepted: 08/27/2021] [Indexed: 11/19/2022]
Abstract
BACKGROUND Cell blocks (CBs) are an essential adjunct in cytopathology practice. The aim of this study was to compare 2 techniques of CB preparation - plasma thrombin (PT) method with sodium alginate (SA) method for overall cellularity, morphological preservation, obscuring artefacts, immunocytochemistry (ICC), suitability for molecular analysis, and cost of preparation. DESIGN A total of 80 fine-needle aspirates from various sites and serous effusion samples were included. Of these cases, by random selection, 40 each were prepared by PT method and SA methods, respectively. The haematoxylin-eosin-stained sections from the formalin-fixed, paraffin-embedded CBs from both methods were evaluated in a blinded fashion by 2 cytopathologists and scored for cellularity, artefacts, and morphological preservation and analysed by χ2 test with Yates correction. We evaluated 6 cases from each method by ICC for a range of membrane, cytoplasmic and nuclear marker expression. DNA was extracted from four cases to evaluate their utility for molecular analysis. RESULTS CB sections from PT and SA techniques showed comparable cellularity and excellent cytomorphological preservation. Blue gel-like artefacts were common in the SA technique but did not interfere with morphological evaluation. ICC staining results were also similar. DNA yield and utility for PCR were also comparable. The SA-CB cost half that of PT-CB (USD 0.4 vs. USD 1). CONCLUSION SA technique of CB preparation is an excellent low-cost alternative to PT method for CB preparation.
Collapse
|
112
|
McAlpine ED, Michelow PM, Celik T. The Dynamics of Pathology Dataset Creation Using Urine Cytology as an Example. Acta Cytol 2021; 66:46-54. [PMID: 34662874 DOI: 10.1159/000519273] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Accepted: 08/26/2021] [Indexed: 11/19/2022]
Abstract
INTRODUCTION Dataset creation is one of the first tasks required for training AI algorithms but is underestimated in pathology. High-quality data are essential for training algorithms and data should be labelled accurately and include sufficient morphological diversity. The dynamics and challenges of labelling a urine cytology dataset using The Paris System (TPS) criteria are presented. METHODS 2,454 images were labelled by pathologist consensus via video conferencing over a 14-day period. During the labelling sessions, the dynamics of the labelling process were recorded. Quality assurance images were randomly selected from images labelled in previous sessions within this study and randomly distributed throughout new labelling sessions. To assess the effect of time on the labelling process, the labelled set of images was split into 2 groups according to the median relative label time and the time taken to label images and intersession agreement were assessed. RESULTS Labelling sessions ranged from 24 m 11 s to 41 m 06 s in length, with a median of 33 m 47 s. The majority of the 2,454 images were labelled as benign urothelial cells, with atypical and malignant urothelial cells more sparsely represented. The time taken to label individual images ranged from 1 s to 42 s with a median of 2.9 s. Labelling times differed significantly among categories, with the median label time for the atypical urothelial category being 7.2 s, followed by the malignant urothelial category at 3.8 s and the benign urothelial category at 2.9 s. The overall intersession agreement for quality assurance images was substantial. The level of agreement differed among classes of urothelial cells - benign and malignant urothelial cell classes showed almost perfect agreement and the atypical urothelial cell class showed moderate agreement. Image labelling times seemed to speed up, and there was no evidence of worsening of intersession agreement with session time. DISCUSSION/CONCLUSION Important aspects of pathology dataset creation are presented, illustrating the significant resources required for labelling a large dataset. We present evidence that the time taken to categorise urine cytology images varies by diagnosis/class. The known challenges relating to the reproducibility of the AUC (atypical) category in TPS when compared to the NHGUC (benign) or HGUC (malignant) categories is also confirmed.
Collapse
|
113
|
Babu S, Kim NW, Wu M, Chan I, Escobar-Hoyos LF, Shroyer KR. Keratin 17 Is a Novel Cytologic Biomarker for Urothelial Carcinoma Diagnosis. Am J Clin Pathol 2021; 156:926-933. [PMID: 34086841 PMCID: PMC8512275 DOI: 10.1093/ajcp/aqab050] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
OBJECTIVES The microscopic features of urine cytology specimens are subjective and may not reliably distinguish between benign urothelial cells and low-grade urothelial carcinoma (UC). Prior studies demonstrated that keratin 17 (K17) detection in biopsies is highly sensitive for UC. The current study aimed to define K17 diagnostic test performance for initial screening and detect recurrent UC in urine specimens. METHODS K17 was detected by immunocytochemistry (ICC) in consecutively collected urine specimens (2018-2019). A qualitative score for the K17 test was determined in 81 samples (discovery cohort) and validated in 98 samples (validation cohort). K17 sensitivity and specificity were analyzed in both cohorts across all grades of UC. RESULTS Based on the discovery cohort, the presence of 5 or more K17 immunoreactive urothelial cells (area under the curve = 0.90; P < .001) was the optimal threshold to define a K17-positive test. The sensitivity of the K17 ICC test for biopsy-confirmed UC was 35 of 36 (97%) and 18 of 21 (86%) in the discovery and validation cohorts, respectively. K17 was positive in 16 of 19 (84%) specimens with biopsy-confirmed low-grade UC and in 34 of 34 (100%) of specimens with high-grade UC. CONCLUSIONS K17 ICC is a highly sensitive diagnostic test for initial screening and detection of recurrence across all grades of UC.
Collapse
|
114
|
Ikeda K, Oboshi W, Hashimoto Y, Komene T, Yamaguchi Y, Sato S, Maruyama S, Furukawa N, Sakabe N, Nagata K. Characterizing the Effect of Processing Technique and Solution Type on Cytomorphology Using Liquid-Based Cytology. Acta Cytol 2021; 66:55-60. [PMID: 34644702 DOI: 10.1159/000519335] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Accepted: 08/31/2021] [Indexed: 11/19/2022]
Abstract
INTRODUCTION Liquid-based cytology (LBC) is increasingly used for nongynecologic applications. However, the cytological preparation of LBC specimens is influenced by the processing technique and the preservative used. In this study, the influence of the processing techniques and preservatives on cell morphology was examined mathematically and statistically. METHODS Cytological specimens were prepared using the ThinPrep (TP), SurePath (SP), and AutoSmear methods, with 5 different preservative solutions. The cytoplasmic and nuclear areas of Papanicolaou-stained specimens were measured for all samples. RESULTS The cytoplasmic and nuclear areas were smaller in cells prepared using the 2 LBC methods, compared to that prepared using the AutoSmear method, irrespective of the preservative used. The cytoplasmic and nuclear areas of cells prepared using the SP method were smaller than those of cells prepared using the TP method, irrespective of the preservative used. There were fewer differences among the cytoplasmic areas of cells prepared with different preservative solutions using the TP method; however, the cytoplasmic areas of cells prepared using the SP method changed with the preservative solution used. CONCLUSIONS The most significant difference affecting the cytoplasmic and nuclear areas was the processing technique. The TP method increased the cytoplasmic and nuclear areas, while the methanol-based PreservCyt solution enabled the highest enlargement of the cell. LBC is a superior preparation technique for standardization of the specimens. Our results offer a better understanding of methods suitable for specimen preparation for developing precision AI-based diagnosis in cytology.
Collapse
|
115
|
Shibata T, Nakagawa M, Coleman HN, Owens SM, Greenfield WW, Sasagawa T, Robeson MS. Evaluation of DNA extraction protocols from liquid-based cytology specimens for studying cervical microbiota. PLoS One 2021; 16:e0237556. [PMID: 34460815 PMCID: PMC8404996 DOI: 10.1371/journal.pone.0237556] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Accepted: 08/12/2021] [Indexed: 12/22/2022] Open
Abstract
Cervical microbiota (CM) are considered an important factor affecting the progression of cervical intraepithelial neoplasia (CIN) and are implicated in the persistence of human papillomavirus (HPV). Collection of liquid-based cytology (LBC) samples is routine for cervical cancer screening and HPV genotyping and can be used for long-term cytological biobanking. We sought to determine whether it is possible to access microbial DNA from LBC specimens, and compared the performance of four different extraction protocols: (ZymoBIOMICS DNA Miniprep Kit; QIAamp PowerFecal Pro DNA Kit; QIAamp DNA Mini Kit; and IndiSpin Pathogen Kit) and their ability to capture the diversity of CM from LBC specimens. LBC specimens from 20 patients (stored for 716 ± 105 days) with CIN values of 2 or 3 were each aliquoted for each of the four kits. Loss of microbial diversity due to long-term LBC storage could not be assessed due to lack of fresh LBC samples. Comparisons with other types of cervical sampling were not performed. We observed that all DNA extraction kits provided equivalent accessibility to the cervical microbial DNA within stored LBC samples. Approximately 80% microbial genera were shared among all DNA extraction protocols. Potential kit contaminants were observed as well. Variation between individuals was a significantly greater influence on the observed microbial composition than was the method of DNA extraction. We also observed that HPV16 was significantly associated with community types that were not dominated by Lactobacillus iners.
Collapse
|
116
|
Bayona A, Benavent P, Muriel A, Abuchaibe C, Sharpe SC, Tarasova V, McIver B, Valderrabano P. Outcomes of repeat fineneedle aspiration biopsy for AUS/FLUS thyroid nodules. Eur J Endocrinol 2021; 185:497-506. [PMID: 34313606 DOI: 10.1530/eje-21-0330] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/28/2021] [Accepted: 07/27/2021] [Indexed: 11/08/2022]
Abstract
OBJECTIVE To determine the proportion of aspirates reclassified into each Bethesda category and to assess the rates of malignancy in each of them on repeat fine-needle aspiration biopsy (RFNA) following an AUS/FLUS diagnosis. DESIGN Systematic review and meta-analysis. METHODS On February 2019, Pubmed/MEDLINE, EMBASE, WoS, and the Cochrane Library were searched for articles published from January 1, 2007. All studies published in English describing RFNA outcomes in AUS/FLUS nodules were included. PRISMA and MOOSE guidelines were followed. Five investigators independently assessed the eligibility of the studies. Two investigators extracted summary data and assessed the risk of bias. Data were pooled using a random-effects model. The rate of malignancy was calculated on resected nodules only (upper limit of true value); and considering all unresected nodules were benign (lower limit of true value). The protocol was registered in PROSPERO (CRD42019123114). RESULTS Of 2937 retrieved studies, 27 were eligible. The meta-analysis was conducted on summary data of 3932 AUS/FLUS thyroid nodules with RFNA. RFNA cytology would reclassify into categories I through VI of Bethesda: 4% (3%, 5%), 48% (43%, 54%), 26% (20%, 32%), 4% (3%, 6%), 5% (3%, 6%), and 2% (1%, 2%) of AUS/FLUS nodules. Malignancy rates of resected nodules were 24% (9%, 38%), 4% (1%, 7%), 40% (28%, 52%), 37% (27%, 47%), 79% (69%, 90%), and 99% (95%, 100%) for categories I through VI of Bethesda. There was high heterogeneity in these data. CONCLUSIONS RFNA reclassified two-thirds of the AUS/FLUS specimens into a more definitive cytological category, with a benign call rate of nearly 50% and a negative predictive value greater than 96%.
Collapse
|
117
|
Guo Y, Peng Q, Wang Y, Li L, Yi X, Yan B, Zou M, Dai G, Guo P, Ma Q, Wu X. The Application of DNA Ploidy Analysis in Large-Scale Population Screening for Cervical Cancer. Acta Cytol 2021; 65:385-392. [PMID: 34482310 DOI: 10.1159/000518052] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Accepted: 06/18/2021] [Indexed: 11/19/2022]
Abstract
OBJECTIVE The objective of this study was to evaluate the application of DNA ploidy analysis in large-scale population screening for cervical cancer. METHODS From March 2016 to March 2019, eligible subjects were enrolled and recommended to undergo DNA ploidy analysis, the ThinPrep cytology test (TCT), and high-risk human papillomavirus (hrHPV) detection concurrently. Patients with positive results were recommended for colposcopy, and biopsy diagnosis was regarded as the "gold standard." We compared the test efficiencies of the 3 methods and compared the efficiency and accuracy of the TCT in our hospital and the "2-cancer screening" project in Hubei Province during the same period. RESULTS Among 20,574 women, the positive rates of DNA ploidy analysis, cytology, and hrHPV testing were 4.01%, 4.71%, and 16.28%, respectively. The sensitivities of these methods for screening for grade 2+ cervical intraepithelial neoplasia were 0.70, 0.68, and 0.96, and their specificities were 0.79, 0.82, and 0.45, respectively. On comparing DNA ploidy analysis with the TCT, there was no significant difference in the sensitivity, specificity, positive predictive value, negative predictive value, and missed diagnosis rate. In opportunistic screening and the 2-cancer screening project, the positive rates of cytology were 4.71% and 2.87%, respectively. And the efficiency and accuracy of the TCT in opportunistic screening were higher than in the 2-cancer screening project. CONCLUSION Therefore, DNA ploidy analysis, which is of low-cost and does not depend on cytopathologists, can replace cytology and be applied in large-scale population screening for cervical cancer.
Collapse
|
118
|
Tafoya M, Judd A, Chiotti K, Dearen K, Jiron K, Chabot-Richards D, Broehm CJ. Performance of a 50-gene next generation sequencing panel with post-centrifuge supernatant cytology fluid in non-small-cell lung cancer. Diagn Cytopathol 2021; 49:1173-1178. [PMID: 34339108 DOI: 10.1002/dc.24844] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2021] [Revised: 07/19/2021] [Accepted: 07/22/2021] [Indexed: 11/07/2022]
Abstract
BACKGROUND Liquid based cytology (LBC) specimens are increasingly utilized for molecular analysis, as results are comparable to molecular analysis performed on traditional specimens (biopsy or cell block). However, there are few studies demonstrating the long-term viability of DNA in LBC samples. METHODS In this study, a 50-gene next generation sequencing (NGS) panel was performed on DNA isolated from post-centrifuged supernatant LBC samples of cases of non-small-cell lung carcinoma. Comparison was made to results of an identical NGS panel performed on a concurrent clinical sample (biopsy or cell block). Quality parameters including DNA concentration, total reads, amplicons with reads under 450 and 350, and variant allele fraction were also compared. For a subset of LBC samples, DNA was isolated after being held for varying extended lengths of time after collection (up to 41 days) at 5°C and results compared. RESULTS Results of NGS mutation analysis were concordant between LBC samples and clinical samples. DNA concentration was on average higher in the LBC samples compared to the clinical samples. The remaining metrics were more variable, but illustrated the adequacy of LBC samples for NGS testing. DNA isolated from LBC samples held for longer periods of time was of good concentration. NGS analysis was successfully performed on all samples, with concordance with results of clinical samples. CONCLUSION DNA isolated directly from LBC fluid is suitable for NGS analysis. DNA is also stable in LBC preservative for extended periods of time before isolation and NGS analysis can subsequently be successfully performed.
Collapse
|
119
|
Podany P, Gilani SM. Hyalinizing trabecular tumor: Cytologic, histologic and molecular features and diagnostic considerations. Ann Diagn Pathol 2021; 54:151803. [PMID: 34385072 DOI: 10.1016/j.anndiagpath.2021.151803] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2021] [Revised: 07/03/2021] [Accepted: 07/25/2021] [Indexed: 12/24/2022]
Abstract
Hyalinizing trabecular tumors are a follicular origin neoplasm of the thyroid that usually present as an asymptomatic, well circumscribed, solitary mass. However, diagnosis of a hyalinizing trabecular tumor may be challenging especially on fine needle aspiration cytology and requires careful examination of the specimen to rule out potential mimickers such as papillary thyroid carcinoma, medullary thyroid carcinoma, paraganglioma, other follicular patterned neoplasms, intrathyroidal parathyroid tissue, and metastatic disease. We will review the cytologic, histologic and molecular features of hyalinizing trabecular tumors that aid in distinction from these mimickers with overlapping morphologic features and help ensure proper diagnosis for appropriate management.
Collapse
|
120
|
Li L, Chen X, Li P, Liu Y, Ma X, Ye YQ. The Value of Ultrasound-Guided Fine-Needle Aspiration Cytology Combined with Puncture Feeling in the Diagnosis of Thyroid Nodules. Acta Cytol 2021; 65:368-376. [PMID: 34350849 DOI: 10.1159/000517168] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2021] [Accepted: 05/10/2021] [Indexed: 11/19/2022]
Abstract
INTRODUCTION There are few studies on the role of puncture feeling in thyroid nodules during ultrasound-guided fine-needle aspiration cytology (US-FNAC), although it is expected to become a new predictive technique. We aimed to analyze the importance of puncture feeling in combination with US-FNAC and investigate whether it can be used as an indicator to predict the nature of thyroid nodules. MATERIALS AND METHODS From January 1, 2018, to October 31, 2020, a total of 623 thyroid nodules were included. Puncture feeling was classified as "soft," "hard," or "hard with grittiness." The correlation between puncture feeling and postoperative pathology and the diagnostic value of FNAC combined with puncture feeling were analyzed, and the influence of thyroid nodule size on puncture feeling, FNAC, and FNAC combined with puncture feeling was studied. We further explored the correlation between puncture feeling and histopathology in Bethesda III and IV thyroid nodules. RESULTS There was a significant correlation between puncture feeling and postoperative pathology (p < 0.001). The sensitivity, negative predictive value, and total coincidence rate of US-FNAC combined with puncture feeling for the diagnosis of thyroid nodules were higher than those of US-FNAC alone (96.1, 83.6, and 94.7% vs. 89.0, 65.5, and 89.7%, respectively). Thyroid nodule size was the influencing factor for puncture feeling, FNAC, and FNAC combined with puncture feeling (p < 0.05 for all). The area under the curve for puncture feeling, FNAC, and FNAC combined with puncture feeling for thyroid nodules of size ≤1 cm was greater than for modules of size >1 cm. Puncture feeling was of great value in diagnosing Bethesda III thyroid nodules (p < 0.001), and all Bethesda IV thyroid nodules had puncture feeling of soft. CONCLUSION Puncture feeling is of great value during US-FNAC. "Hard" and "hard with grittiness" were indicators for malignancy, while "soft" indicated that the thyroid nodule was likely to be benign. The diagnostic value of US-FNAC combined with puncture feeling for thyroid nodules is higher than US-FNAC alone, especially when nodule size is ≤1 cm. Puncture feeling is of great value in predicting the nature of Bethesda III thyroid nodules.
Collapse
|
121
|
Hallikeri K, Babu B, Sudhakaran A, Monteiro R. Cell Block and Its Impact in the Diagnosis of Jaw Lesions over Fine Needle Aspiration Cytology. Acta Cytol 2021; 65:361-367. [PMID: 34237724 DOI: 10.1159/000517166] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2021] [Accepted: 05/09/2021] [Indexed: 12/13/2022]
Abstract
OBJECTIVES To determine the role and efficacy of fine needle aspiration cytology (FNAC) and cell block in diagnosis of jaw lesions and compare the agreement between FNAC and cell block to predict the diagnosis. METHOD The sample comprised 51 cases, including 12 odontogenic keratocysts (OKCs), 8 ameloblastomas, 22 radicular cysts, 7 dentigerous cysts, and 1 each of intraosseous mucoepidermoid carcinoma (MEC) and adenomatoid odontogenic tumor (AOT). FNAC samples remaining after hematoxylin and eosin (H&E)-stained cytosmear diagnosis were centrifuged at 3,000 rpm for 10 min. The supernatant was discarded and sediment mixed with 2-3 mL alcohol and filtered. To this, 10% formalin was added, filtered, taken for routine processing, and stained with H&E. The result of FNAC smear and cell block was compared with histopathological diagnosis. RESULTS On cytological examination of the smears, 7 OKCs and 22 radicular cysts were diagnosed, whereas ameloblastomas, AOT, intraosseous MEC, and dentigerous cysts were not. This gave an agreement of 56.8% with the biopsy reports. Cell block sections stained with H&E of 12 OKCs, 22 radicular cysts, 1 MEC, and 3 cases of ameloblastoma offered a diagnosis in accordance with the biopsies giving an agreement of 74.5%, while dentigerous cyst and AOT failed to do so. In comparison with FNAC, additionally 5 cases of OKC and 1 of MEC could be detected, and in ameloblastoma, out of 8 cases, only 3 yielded a concordant diagnosis through the cell block technique. CONCLUSION In comparison with FNAC, the architectural pattern and the morphology of the cells were better preserved by the cell block technique. This substantiates that cell block could be used as an ancillary technique to aid in definitive diagnosis of head and neck swellings.
Collapse
|
122
|
Wang H, Weiss VL, Ely K, Johnson J, Coogan A, Borinstein SC, Mannion K, Virgin F, Liang J. Application of the Milan System for Reporting Pediatric Salivary Gland Cytopathology: Analysis of histologic follow-up, risk of malignancy, and diagnostic accuracy. Cancer Cytopathol 2021; 129:555-565. [PMID: 33595882 PMCID: PMC10030063 DOI: 10.1002/cncy.22415] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2020] [Revised: 01/07/2021] [Accepted: 01/19/2021] [Indexed: 11/10/2022]
Abstract
BACKGROUND The diagnosis and management of salivary gland tumors in pediatric patients can be challenging. The utility of fine-needle aspiration (FNA) cytopathology and the performance of the Milan System for Reporting Salivary Gland Cytopathology (MSRSGC) in this age group have not been systematically assessed. The paucity of data has contributed to the controversial role of FNA cytopathology in the presurgical management of these patients. METHODS The authors retrospectively analyzed 104 pediatric salivary gland FNAs (2000-2020). A correlation with the available histopathologic follow-up (n = 54) was performed. The distribution percentages, the risk of neoplasm (RON), and the risk of malignancy (ROM) were assessed for each category of the MSRSGC. RESULTS The overall sensitivity, specificity, negative predictive value, and positive predictive value of pediatric salivary gland FNAs were 80%, 97%, and 92%, respectively. The RON values for the nondiagnostic, nonneoplastic, atypia of undetermined significance, benign neoplasm, salivary gland neoplasm of uncertain malignant potential, suspicious for malignancy, and malignant categories were 60%, 11%, 100%, 100%, 100%, 100%, and 100%, respectively, whereas the ROM values were 0%, 11%, 100%, 6%, 67%, 100%, and 100%, respectively. The percentage of nonneoplastic FNAs was greater in comparison with the adult population (52% vs 8%). All neoplasms in patients aged 0 to 10 years were malignant, whereas benign neoplasms occurred only in patients aged ≥11 years; this supported an inverse correlation between age and malignancy rate in salivary gland neoplasms. CONCLUSIONS FNA cytopathology demonstrates excellent diagnostic performance in differentiating malignant and benign pediatric salivary gland lesions. The MSRSGC is a valuable tool for standardization of the reporting and preoperative risk stratification of these lesions.
Collapse
|
123
|
Crescenzi A, Palermo A, Trimboli P. Cancer prevalence in the subcategories of the indeterminate class III (AUS/FLUS) of the Bethesda system for thyroid cytology: a meta-analysis. J Endocrinol Invest 2021; 44:1343-1351. [PMID: 33590467 DOI: 10.1007/s40618-021-01526-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/03/2020] [Accepted: 02/01/2021] [Indexed: 12/18/2022]
Abstract
PURPOSE The indeterminate cytologic report represents a major challenge in the field of thyroid nodule. The indeterminate class III of the Bethesda classification system (i.e., AUS/FLUS) includes a heterogeneous group of subcategories characterized by doubtful nuclear and/or architectural atypia. The study aim was to conduct a systematic review and meta-analysis to evaluate the rate of malignancy in each subcategory of Bethesda III. METHODS PubMed, CENTRAL, and Scopus databases were searched until April 2020. Original articles reporting data on the subcategories of Bethesda III were included. The histological diagnosis was the reference standard to classify true/false negative and true/false positive cases. RESULTS The pooled cancer prevalence in each subcategory of Bethesda III was estimated using a random-effects model. Twenty-three papers with 4241 nodules were included. Overall, 1163 (27.4%) were malignant. The cancer rate observed in the subcategories ranged from 15%, in "Hürthle cell aspirates with low risk pattern", to 44%, in "Focal cytologic atypia". CONCLUSIONS The overall cancer rate found in the Bethesda III ranged more largely than that originally estimated (10-30%) and varied among any scenarios. These evidence-based data represent a reference for the clinical management of these patients.
Collapse
|
124
|
Morimoto Y, Oya T, Ichimura-Shimizu M, Matsumoto M, Ogawa H, Kobayashi T, Sumida S, Kakimoto T, Yamashita M, Cheng C, Tsuneyama K. Applying Probe Electrospray Ionization Mass Spectrometry to Cytological Diagnosis: A Preliminary Study by Using Cultured Lung Cancer Cells. Acta Cytol 2021; 65:430-439. [PMID: 34098551 DOI: 10.1159/000516639] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2020] [Accepted: 04/18/2021] [Indexed: 11/19/2022]
Abstract
OBJECTIVES Cytology and histology are 2 indispensable diagnostic tools for cancer diagnosis, which are rapidly increasing in importance with aging populations. We applied mass spectrometry (MS) as a rapid approach for swiftly acquiring nonmorphological information of interested cells. Conventional MS, which primarily rely on promoting ionization by pre-applying a matrix to cells, has the drawback of time-consuming both on data acquisition and analysis. As an emerging method, probe electrospray ionization-MS (PESI-MS) with a dedicated probe is capable to pierce sample and measure specimen in small amounts, either liquid or solid, without the requirement for sample pretreatment. Furthermore, PESI-MS is timesaving compared to the conventional MS. Herein, we investigated the capability of PESI-MS to characterize the cell types derived from the respiratory tract of human tissues. STUDY DESIGN PESI-MS analyses with DPiMS-2020 were performed on various type of cultured cells including 5 lung squamous cell carcinomas, 5 lung adenocarcinomas, 5 small-cell carcinomas, 4 malignant mesotheliomas, and 2 normal controls. RESULTS Several characteristic peaks were detected at around m/z 200 and 800 that were common in all samples. As expected, partial least squares-discriminant analysis of PESI-MS data distinguished the cancer cell types from normal control cells. Moreover, distinct clusters divided squamous cell carcinoma from adenocarcinoma. CONCLUSION PESI-MS presented a promising potential as a novel diagnostic modality for swiftly acquiring specific cytological information.
Collapse
|
125
|
Morito S, Nitanda T, Tsukamoto R, Kamoshida S, Yasui H, Itoh T, Ohsaki H. Rapid Cell Transfer by Means of Nylon Mesh to Improve Cellular Diagnosis: The Role of Immunocytochemistry. Acta Cytol 2021; 65:424-429. [PMID: 34098550 DOI: 10.1159/000516555] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2021] [Accepted: 04/10/2021] [Indexed: 11/19/2022]
Abstract
Immunocytochemistry (ICC) is an important ancillary technique in clinical cytology for not only identifying and characterizing tumor cells but also gaining prognostic or therapeutic information. Although cell blocks are often prepared for immunocytochemical evaluation of body cavity fluid and fine-needle aspiration specimens, they are not suitable for hypocellular samples. Liquid-based cytology can help prepare additional smears from residual cytological specimens. However, since conventional methods are used for nongynecological specimens in most laboratories, ICC is often limited by the number of cytological smears. Cell transfer methods permit to evaluate several immunocytochemical markers in a single cytological smear. Yet, these methods have some limitations; for example, they are time-consuming (about 3-40 h) and medium membranes with their attached cells are occasionally stretched or torn when peeled off the slides. Therefore, in an attempt to solve these problems, we developed a rapid and reliable cell transfer method using a nylon mesh. Our method requires no special equipment or reagent and can significantly reduce the turnaround time, as compared to previous methods.
Collapse
|