101
|
Thompson JG, van der Sterren W, Bakhutashvili I, van der Bom IM, Radaelli AG, Karanian JW, Esparza-Trujillo J, Woods DL, Lewis AL, Wood BJ, Pritchard WF. Distribution and Detection of Radiopaque Beads after Hepatic Transarterial Embolization in Swine: Cone-Beam CT versus MicroCT. J Vasc Interv Radiol 2018; 29:568-574. [PMID: 29500000 PMCID: PMC5869084 DOI: 10.1016/j.jvir.2017.11.011] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2017] [Revised: 10/28/2017] [Accepted: 11/13/2017] [Indexed: 12/28/2022] Open
Abstract
PURPOSE To determine the true distribution of radiopaque beads (ROBs) after hepatic embolization in swine as imaged by micro-computed tomography (microCT) compared with in vivo cone-beam computerized tomography (CT) imaged at different kVp settings. MATERIALS AND METHODS Swine (n = 3) underwent hepatic transarterial embolization (n = 6) with the use of 70-150-μm ROBs under fluoroscopic guidance. After stasis, in vivo cone-beam CT was performed at 120, 100, and 80 kVp. The animal was euthanized, the liver resected, and microCT with 17 μm resolution performed on embolized tissue samples. The resulting cone-beam CT and microCT data were segmented and registered. Total vessel length, minimum volume-enclosing ellipsoid (MVEE), and number of independent volumes were measured. Maximum-intensity projections (MIPs) were generated for each cone-beam CT. RESULTS Metrics for all cone-beam CT segmentations differed significantly from microCT segmentations. Segmentations at 80 kVp presented significantly greater vessel length, MVEE, and number of independent volumes compared with 100 kVp and 120 kVp. In addition, 100 kVp segmentations presented significantly greater vessel length than 120 kVp. MIPs presented greater visualization than cone-beam CT segmentations and improved as kVp decreased. CONCLUSIONS The full ROB distribution was more extensive than was apparent on cone-beam CT. Quantitative measures of embolic distribution demonstrated significantly better correlation with microCT with decreasing kVp. Similarly, qualitative analysis of MIPs showed improved visualization of beads with decreasing kVp. These findings demonstrate the clinical value of 80 kVp and 100 kVp protocols in the imaging of radiopaque embolizations compared with 120 kVp. However, considerations on X-ray penetration and dose may favor use of 100 kVp imaging over 80 kVp.
Collapse
|
102
|
Lee WC, Fang HY, Wu CJ. How to treat the combination of coronary artery fistula and occluded coronary artery: A case report. Medicine (Baltimore) 2018; 97:e0363. [PMID: 29620668 PMCID: PMC5902290 DOI: 10.1097/md.0000000000010363] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
RATIONALE Coronary artery fistulae (CAF) are uncommon and are reported in 0.25% of patients undergoing routine coronary angiography. The combination of severe coronary artery disease and a CAF was rare. PATIENT CONCERNS A 76-year-old man presented unstable angina. DIAGNOSES Coronary angiography showed a subtotal occlusion lesion and a CAF at left anterior descending artery. INTERVENTIONS The combination of transcatheter coil embolization and a drug-eluting stent was used for this problem. OUTCOMES The patient was symptom-free and had regularly followed up as an outpatient for three years. LESSONS The combination of a CAF and atherosclerotic change in the same site of the coronary artery is unique. It is feasible to solve the combination of CAF and severe coronary atherosclerotic lesion by transcatheter coil embolization and stent implantation. A big case series study is necessary to evaluate the safety and efficacy of the technique of transcatheter coil embolization and stent implantation in the patients with severe coronary atherosclerotic lesion and a CAF.
Collapse
|
103
|
Flores BC, See AP, Weiner GM, Jankowitz BT, Ducruet AF, Albuquerque FC. Use of the Apollo detachable-tip microcatheter for endovascular embolization of arteriovenous malformations and arteriovenous fistulas. J Neurosurg 2018; 130:963-971. [PMID: 29570006 DOI: 10.3171/2017.9.jns17397] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2017] [Accepted: 09/11/2017] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Liquid embolic agents have revolutionized endovascular management of arteriovenous malformations (AVMs) and arteriovenous fistulas (AVFs). Nonetheless, since 2005, the US FDA has received more than 100 reports of microcatheter breakage or entrapment related to Onyx embolization, including 9 deaths. In 2014, the Apollo detachable-tip microcatheter became the first of its kind available in the US. Since then, few reports on its safety have been published. METHODS The authors conducted a retrospective review of endovascular cases by searching the patient databases at 2 tertiary cerebrovascular centers (Barrow Neurological Institute and University of Pittsburgh Medical Center). Patients who underwent endovascular embolization of an AVM or AVF using the Apollo microcatheter were identified. Patient demographics and lesion characteristics were collected. The authors analyzed Apollo-specific endovascular variables, such as number of microcatheterizations, sessions, and pedicles embolized; microcatheter tip detachment status; obliteration rate; and endovascular- and microcatheter-related morbidity and mortality. RESULTS From July 2014 to October 2016, a total of 177 embolizations using the Apollo microcatheter were performed in 61 patients (mean age 40.3 years). The most frequent presentation was hemorrhage (22/61, 36.1%). Most lesions were AVMs (51/61, 83.6%; mean diameter 30.6 mm). The mean Spetzler-Martin grade was 2.4. Thirty-nine (76.5%) of 51 patients with AVMs underwent resection. Microcatheterization was successful in 172 pedicles. Most patients (50/61, 82%) underwent a single embolization session. The mean number of pedicles per session was 2.5 (range 1-7). Onyx-18 was used in 103 (59.9%), N-butyl cyanoacrylate (NBCA) in 44 (25.6%), and Onyx-34 in 25 (14.5%) of the 172 embolizations. In 45.9% (28/61) of the patients, lesion obliteration of 75% or greater was achieved. Tip detachment occurred in 19.2% (33/172) of microcatheters. Fifty-three (86.9%) of the 61 patients who underwent embolization with the Apollo microcatheter had good functional outcomes (modified Rankin Scale score 0-2). No unintended microcatheter fractures or related morbidity was observed. One patient died of intraprocedural complications unrelated to microcatheter selection. In the univariate analysis, microcatheter tip detachment (p = 0.12), single embolized pedicles (p = 0.12), and smaller AVM nidus diameter (p = 0.17) correlated positively with high obliteration rates (> 90%). In the multivariate analysis, microcatheter tip detachment was the only independent variable associated with high obliteration rates (OR 9.5; p = 0.03). CONCLUSIONS The use of the Apollo detachable-tip microcatheter for embolization of AVMs and AVFs is associated with high rates of successful catheterization and obliteration and low rates of morbidity and mortality. The microcatheter was retrieved in all cases, even after prolonged injections in distal branch pedicles, often with significant reflux. This study represents the largest case series on the application of the Apollo microcatheter for neurointerventional procedures.
Collapse
|
104
|
Son W, Kang DH, Kim BM, Park J, Kim YS. Retrograde Snare-Assisted Rescue via Anterior Communicating Artery for Lost Access During Multiple Overlapping Pipeline Embolization Device Placement. World Neurosurg 2018. [PMID: 29524711 DOI: 10.1016/j.wneu.2018.02.150] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
BACKGROUND The Pipeline embolization device (PED; ev3, Irvine, California, USA) has been used to divert flow away from an aneurysm sac. The risk of complications may increase for flow diversion with giant aneurysms because these cases may require multiple overlapping PEDs, which makes the technique highly complex. CASE DESCRIPTION We report a rescue technical strategy for lost access during multiple overlapping PED placement for a giant, fusiform cavernous aneurysm. CONCLUSIONS By using the collateral circulation as an alternative rescue route, intraprocedural loss of distal access may be salvaged.
Collapse
|
105
|
Frölich AM, Nawka MT, Ernst M, Frischmuth I, Fiehler J, Buhk JH. Intra-aneurysmal flow disruption after implantation of the Medina® Embolization Device depends on aneurysm neck coverage. PLoS One 2018; 13:e0191975. [PMID: 29408857 PMCID: PMC5800678 DOI: 10.1371/journal.pone.0191975] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2017] [Accepted: 01/15/2018] [Indexed: 11/21/2022] Open
Abstract
Background and purpose Flow disruption achieved by braided intrasaccular implants is a novel treatment strategy for cerebrovascular aneurysms. We hypothesized that the degree of intra-aneurysmal flow disruption can be quantified in vitro and is influenced by device position across the aneurysm neck. We tested this hypothesis using the Medina® Embolization Device (MED). Methods Ten different patient-specific elastic vascular models were manufactured. Models were connected to a pulsatile flow circuit, filled with a blood-mimicking fluid and treated by two operators using a single MED. Intra-aneurysmal flow velocity was measured using conventional and high-frequency digital subtraction angiography (HF-DSA) before and after each deployment. Aneurysm neck coverage by the implanted devices was assessed with flat detector computed tomography on a three-point Likert scale. Results A total of 80 individual MED deployments were performed by the two operators. The mean intra-aneurysmal flow velocity reduction after MED implantation was 33.6% (27.5–39.7%). No significant differences in neck coverage (p = 0.99) or flow disruption (p = 0.84) were observed between operators. The degree of flow disruption significantly correlated with neck coverage (ρ = 0.42, 95% CI: 0.21–0.59, p = 0.002) as well as with neck area (ρ = -0,35, 95% CI: -0.54 –-0.13, p = 0.024). On multiple regression analysis, both neck coverage and total neck area were independent predictors of flow disruption. Conclusions The degree of intra-aneurysmal flow disruption after MED implantation can be quantified in vitro and varies considerably between different aneurysms and different device configurations. Optimal device coverage across the aneurysm neck improves flow disruption and may thus contribute to aneurysm occlusion.
Collapse
|
106
|
Sedat J, Chau Y, Gaudart J, Sachet M, Beuil S, Lonjon M. Stent-assisted coiling of intracranial aneurysms using LEO stents: long-term follow-up in 153 patients. Neuroradiology 2017; 60:211-219. [PMID: 29273960 DOI: 10.1007/s00234-017-1965-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2017] [Accepted: 12/15/2017] [Indexed: 01/31/2023]
Abstract
PURPOSE Coiling associated with placement of a self-expandable intracranial stent has improved the treatment of intracranial wide-necked aneurysms. Little is known, however, about the durability of this treatment. The purpose of this report is to present our experience with the LEO stent and to evaluate the complications, effectiveness, and long-term results of this technique. METHODS We analyzed the records of 155 intracranial unruptured aneurysms that were treated by stent-assisted coiling with a LEO stent between 2008 and 2012. Procedural, early post-procedural, and delayed complications were recorded. Clinical and angiographic follow-up of patients was conducted over a period of at least 36 months. RESULTS No procedural mortality was observed. One-month morbidity was observed in 14 out of 153 patients (9,15%). One hundred thirty-eight patients (with 140 aneurysms) had clinical and angiographic follow-up for more than 36 months. No aneurysm rupture was observed during follow-up. Four patients presented an intra-stent stenosis at 8 months, and 6 patients who had an early recurrence were retreated. Final results showed 85% complete occlusion, 13% neck remnants, and 2% stable incomplete occlusion. CONCLUSION Stent-assisted coiling with the LEO stent is a safe and effective treatment for unruptured intracranial aneurysms. The long-term clinical outcomes with the LEO stent are excellent with a high rate of complete occlusion that is stable over time.
Collapse
|
107
|
Adeeb N, Moore JM, Wirtz M, Griessenauer CJ, Foreman PM, Shallwani H, Gupta R, Dmytriw AA, Motiei-Langroudi R, Alturki A, Harrigan MR, Siddiqui AH, Levy EI, Thomas AJ, Ogilvy CS. Predictors of Incomplete Occlusion following Pipeline Embolization of Intracranial Aneurysms: Is It Less Effective in Older Patients? AJNR Am J Neuroradiol 2017; 38:2295-2300. [PMID: 28912285 DOI: 10.3174/ajnr.a5375] [Citation(s) in RCA: 49] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2017] [Accepted: 07/08/2017] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Flow diversion with the Pipeline Embolization Device (PED) for the treatment of intracranial aneurysms is associated with a high rate of aneurysm occlusion. However, clinical and radiographic predictors of incomplete aneurysm occlusion are poorly defined. In this study, predictors of incomplete occlusion at last angiographic follow-up after PED treatment were assessed. MATERIALS AND METHODS A retrospective analysis of consecutive aneurysms treated with the PED between 2009 and 2016, at 3 academic institutions in the United States, was performed. Cases with angiographic follow-up were selected to evaluate factors predictive of incomplete aneurysm occlusion at last follow-up. RESULTS We identified 465 aneurysms treated with the PED; 380 (81.7%) aneurysms (329 procedures; median age, 58 years; female/male ratio, 4.8:1) had angiographic follow-up, and were included. Complete occlusion (100%) was achieved in 78.2% of aneurysms. Near-complete (90%-99%) and partial (<90%) occlusion were collectively achieved in 21.8% of aneurysms and defined as incomplete occlusion. Of aneurysms followed for at least 12 months (211 of 380), complete occlusion was achieved in 83.9%. Older age (older than 70 years), nonsmoking status, aneurysm location within the posterior communicating artery or posterior circulation, greater aneurysm maximal diameter (≥21 mm), and shorter follow-up time (<12 months) were significantly associated with incomplete aneurysm occlusion at last angiographic follow-up on univariable analysis. However, on multivariable logistic regression, only age, smoking status, and duration of follow-up were independently associated with occlusion status. CONCLUSIONS Complete occlusion following PED treatment of intracranial aneurysms can be influenced by several factors related to the patient, aneurysm, and treatment. Of these factors, older age (older than 70 years) and nonsmoking status were independent predictors of incomplete occlusion. While the physiologic explanation for these findings remains unknown, identification of factors predictive of incomplete aneurysm occlusion following PED placement can assist in patient selection and counseling and might provide insight into the biologic factors affecting endothelialization.
Collapse
|
108
|
Medical Devices; Gastroenterology-Urology Devices; Classification of the Prostatic Artery Embolization Device. Final order. FEDERAL REGISTER 2017; 82:52649-52651. [PMID: 29231691] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The Food and Drug Administration (FDA or we) is classifying the prostatic artery embolization device into class II (special controls). The special controls that apply to the device type are identified in this order and will be part of the codified language for the prostatic artery embolization device's classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.
Collapse
|
109
|
Boyle AJ, Wierzbicki MA, Herting S, Weems AC, Nathan A, Hwang W, Maitland DJ. In vitro performance of a shape memory polymer foam-coated coil embolization device. Med Eng Phys 2017; 49:56-62. [PMID: 28774685 PMCID: PMC5819332 DOI: 10.1016/j.medengphy.2017.07.009] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2017] [Accepted: 07/17/2017] [Indexed: 01/21/2023]
Abstract
Intracranial saccular aneurysm treatment using endovascular embolization devices are limited by aneurysm recurrence that can lead to aneurysm rupture. A shape memory polymer (SMP) foam-coated coil (FCC) embolization device was designed to increase packing density and improve tissue healing compared to current commercial devices. FCC devices were fabricated and tested using in vitro models to assess feasibility for clinical treatment of intracranial saccular aneurysms. FCC devices demonstrated smooth delivery through tortuous pathways similar to control devices as well as greater than 10 min working time for clinical repositioning during deployment. Furthermore, the devices passed pilot verification tests for particulates, chemical leachables, and cytocompatibility. Finally, devices were successfully implanted in an in vitro saccular aneurysm model with large packing density. Though improvements and future studies evaluating device stiffness were identified as a necessity, the FCC device demonstrates effective delivery and packing performance that provides great promise for clinical application of the device in treatment of intracranial saccular aneurysms.
Collapse
|
110
|
Heit JJ, Ball RL, Telischak NA, Do HM, Dodd RL, Steinberg GK, Chang SD, Wintermark M, Marks MP. Patient Outcomes and Cerebral Infarction after Ruptured Anterior Communicating Artery Aneurysm Treatment. AJNR Am J Neuroradiol 2017; 38:2119-2125. [PMID: 28882863 DOI: 10.3174/ajnr.a5355] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2017] [Accepted: 06/16/2017] [Indexed: 01/16/2023]
Abstract
BACKGROUND AND PURPOSE Anterior communicating artery aneurysm rupture and treatment is associated with high rates of dependency, which are more severe after clipping compared with coiling. To determine whether ischemic injury might account for these differences, we characterized cerebral infarction burden, infarction patterns, and patient outcomes after surgical or endovascular treatment of ruptured anterior communicating artery aneurysms. MATERIALS AND METHODS We performed a retrospective cohort study of consecutive patients with ruptured anterior communicating artery aneurysms. Patient data and neuroimaging studies were reviewed. A propensity score for outcome measures was calculated to account for the nonrandom assignment to treatment. Primary outcome was the frequency of frontal lobe and striatum ischemic injury. Secondary outcomes were patient mortality and clinical outcome at discharge and at 3 months. RESULTS Coiled patients were older (median, 55 versus 50 years; P = .03), presented with a worse clinical status (60% with Hunt and Hess Score >2 versus 34% in clipped patients; P = .02), had a higher modified Fisher grade (P = .01), and were more likely to present with intraventricular hemorrhage (78% versus 56%; P = .03). Ischemic frontal lobe infarction (OR, 2.9; 95% CI, 1.1-8.4; P = .03) and recurrent artery of Heubner infarction (OR, 20.9; 95% CI, 3.5-403.7; P < .001) were more common in clipped patients. Clipped patients were more likely to be functionally dependent at discharge (OR, 3.2; P = .05) compared with coiled patients. Mortality and clinical outcome at 3 months were similar between coiled and clipped patients. CONCLUSIONS Frontal lobe and recurrent artery of Heubner infarctions are more common after surgical clipping of ruptured anterior communicating artery aneurysms, and are associated with poorer clinical outcomes at discharge.
Collapse
|
111
|
Xu J, Lu X, Zhang Y, Yang H, Yu X. Laparoscopic associating liver tourniquet and portal ligation combined rescue transhepatic arterial embolization for staged hepatectomy: A case report. Medicine (Baltimore) 2017; 96:e8378. [PMID: 29069032 PMCID: PMC5671865 DOI: 10.1097/md.0000000000008378] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
RATIONALE Staged hepatectomy is an important surgical method for large hepatocellular carcinoma (HCC). However, the insufficient future liver remnant (FLR) is still the major barrier in stage II hepatectomy. We herein reported a case of laparoscopic associating liver tourniquet and portal ligation combined rescue transhepatic arterial embolization (TAE) for staged hepatectomy. PATIENT CONCERNS Laparoscopic associating liver tourniquet and portal ligation for staged hepatectomy (ALTPS) was performed for cirrhotic HCC in stage I. To stimulate the growth of FLR, a "rescue" TAE was initiated before stage II. DIAGNOSE HCC with hepatitis B cirrhosis. OUTCOMES Two weeks later after TAE, the FLR achieved sufficient hypertrophy and stage II surgery was successfully performed. The patient was discharged 7 days after the second stage without serious complication. During the follow-up at postoperative 6 months, the patient underwent radiofrequency ablation, because contrast-enhanced ultrasonography showed 1 cm tumor recurrence in the remnant liver. LESSONS Rescue TAE plays an important role to stimulate the increasing of FLR after ALTPS.
Collapse
|
112
|
Lv X, Song C, He H, Jiang C, Li Y. Transvenous retrograde AVM embolization: Indications, techniques, complications and outcomes. Interv Neuroradiol 2017; 23:504-509. [PMID: 28675345 PMCID: PMC5624411 DOI: 10.1177/1591019917716817] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
Objective Transvenous retrograde arteriovenous malformation (AVM) embolization (TRAE) has been proposed. The present study was to review the techniques, their conjunctions and effectiveness. Methods Eligible related articles were identified by searching the PubMed and Web of Science databases using "transvenous" and "arteriovenous malformation." Results A total of 16 eligible studies, with 60 cases of AVM treated with TRAE, were analyzed. Prior to TRAE procedure, transarterial Onyx 18 was performed in 23 (38.3%), cyanoacrylate in three (5%) and coiling in two (3.3%), neurosurgery in one (1.7%) and radiosurgery in three (5%). These prior treatments were used to reduce the size of the nidus to <3 cm and TRAE was performed. One anterior choroidal artery aneurysm was coiled before TRAE. Systemic hypotension (blood pressure<100 mmHg) occurred in six (10%) patients and local hypotension (proximal arterial temporary balloon protection) in five (8.3%) patients. Complete obliteration was achieved in 56 (93.3%) AVMs, four (6.7%) with residual, of which one was supplemented with radiosurgery. During mean one-year follow-up (1 month to 3.2 years), there were five cases (8.3%) of permanent disability and one (1.7%) mortality resulting from initial hemorrhage. Fifty-four (90%) patients were independent (mRS ≤ 2) at follow-up. Ruptured AVMs and Spetzler-Martin I-III were associated with a high cure rate. Conclusion According to previous reports, selected AVMs could undergo TRAE. TRAE is safe and curative with Onyx after the nidus size is reduced sufficiently by transarterial embolization, neurosurgery or radiosurgery, with or without the aid of proximal arterial temporary balloon protection.
Collapse
|
113
|
Texakalidis P, Bekelis K, Atallah E, Tjoumakaris S, Rosenwasser RH, Jabbour P. Flow diversion with the pipeline embolization device for patients with intracranial aneurysms and antiplatelet therapy: A systematic literature review. Clin Neurol Neurosurg 2017; 161:78-87. [PMID: 28863286 DOI: 10.1016/j.clineuro.2017.08.003] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2017] [Revised: 08/01/2017] [Accepted: 08/07/2017] [Indexed: 11/17/2022]
Abstract
Flow diversion with the Pipeline Embolization Device (PED) is reported as a safe and efficient treatment for patients with intracranial aneurysms; however, literature discussing the antiplatelet (APT) regimen used before and after the PED is limited. Our aim was to systematically review and summarize available data regarding the APT regimen and the platelet function test (PFT) that was used. We also sought to provide an overview of the aneurysm morphologies and adverse event rates associated with the PED use. This systematic review was conducted according to the PRISMA statement and eligible studies were identified through search of the PubMed and Cochrane databases. We reviewed 28 studies, involving 1556 patients that underwent aneurysm treatment with the PED. The preprocedural aspirin (ASA) 300- 325mg (2-14days) combined with clopidogrel 75mg (3 to >10days) were used as a treatment strategy in 61.7% of patients and ASA 81mg with clopidogrel 75mg for 5-10days for 27%. Patients who received low versus high dose pre-PED ASA, were at less risk for a hemorrhagic event (0.7% versus 3.3%, p=0.053); however no statistical significance was reached. There was also lack of relationship between patients that received low versus high preprocedural ASA in terms of thromboembolic events. Regarding postprocedural APT, ASA (>6months) and clopidogrel (3- 12 months) was the regimen of choice for 93% of patients. Most studies conducted at least one PFT, most common being the VerifyNow. The most frequently reported target P2Y12 Reaction unit (PRU) and Aspirin Reaction Unit (ARU) values were <230 and <550 respectively. There was no statistically demonstrable difference in regards to thrombotic events between centers that conducted at least one PFT and centers that did not test their patients with a PFT. The overall rates of symptomatic thrombotic episodes were 6.6% and hemorrhagic were 3%. The pre- and post-PED APT dose and duration varies across different institutions. More prospective studies are needed to compare the efficacy of different APT agents and reach conclusions regarding use of PFT and platelet reaction values in order to decrease hemorrhagic and thromboembolic complications associated with the PED.
Collapse
|
114
|
Lim JW, Lee J, Cho YD. Progressive Occlusion of Small Saccular Aneurysms Incompletely Occluded After Stent-Assisted Coil Embolization : Analysis of Related Factors and Long-Term Outcomes. Clin Neuroradiol 2017; 28:569-577. [PMID: 28791434 DOI: 10.1007/s00062-017-0612-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2017] [Accepted: 07/18/2017] [Indexed: 12/23/2022]
Abstract
PURPOSE Incompletely occluded aneurysms after coil embolization are subject to recanalization but occasionally progress to a totally occluded state. Deployed stents may actually promote thrombosis of coiled aneurysms. We evaluated outcomes of small aneurysms (<10 mm) wherein saccular filling with contrast medium was evident after stent-assisted coiling, assessing factors implicated in subsequent progressive occlusion. METHODS Between September 2012 and June 2016, a total of 463 intracranial aneurysms were treated by stent-assisted coil embolization. Of these, 132 small saccular aneurysms displayed saccular filling with contrast medium in the immediate aftermath of coiling. Progressive thrombosis was defined as complete aneurysmal occlusion at the 6‑month follow-up point. Rates of progressive occlusion and factors predisposing to this were analyzed via binary logistic regression. RESULTS In 101 (76.5%) of the 132 intracranial aneurysms, complete occlusion was observed in follow-up imaging studies at 6 months. Binary logistic regression analysis indicated that progressive occlusion was linked to smaller neck diameter (odds ratio [OR] = 1.533; p = 0.003), hyperlipidemia (OR = 3.329; p = 0.036) and stent type (p = 0.031). The LVIS stent is especially susceptible to progressive thrombosis, more so than Neuroform (OR = 0.098; p = 0.008) or Enterprise (OR = 0.317; p = 0.098) stents. In 57 instances of progressive thrombosis, followed for ≥12 months (mean 25.0 ± 10.7 months), 56 (98.2%) were stable, with minor recanalization noted once (1.8%) and no major recanalization. CONCLUSION Aneurysms associated with smaller diameter necks, hyperlipidemic states and LVIS stent deployment may be inclined to possible thrombosis, if occlusion immediately after stent-assisted coil embolization is incomplete. In such instances, excellent long-term durability is anticipated.
Collapse
|
115
|
Adeeb N, Moore JM, Griessenauer CJ, Foreman PM, Shallwani H, Dmytriw AA, Shakir H, Siddiqui AH, Levy EI, Davies JM, Harrigan MR, Thomas AJ, Ogilvy CS. Treatment of Tandem Internal Carotid Artery Aneurysms Using a Single Pipeline Embolization Device: Evaluation of Safety and Efficacy. AJNR Am J Neuroradiol 2017; 38:1605-1609. [PMID: 28522668 DOI: 10.3174/ajnr.a5221] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2017] [Accepted: 03/13/2017] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Tandem aneurysms are defined as multiple aneurysms located in close proximity on the same parent vessel. Endovascular treatment of these aneurysms has rarely been reported. Our aim was to evaluate the safety and efficacy of a single Pipeline Embolization Device for the treatment of tandem aneurysms of the internal carotid artery. MATERIALS AND METHODS A retrospective analysis of consecutive aneurysms treated with the Pipeline Embolization Device between 2009 and 2016 at 3 institutions in the United States was performed. Cases included aneurysms of the ICA treated with a single Pipeline Embolization Device, and they were divided into tandem versus solitary. Angiographic and clinical outcomes were compared. RESULTS The solitary group (median age, 58 years) underwent 184 Pipeline Embolization Device procedures for 184 aneurysms. The tandem group (median age, 50.5 years) underwent 34 procedures for 78 aneurysms. Aneurysms were primarily located along the paraophthalmic segment of the ICA in both the single and tandem groups (72.3% versus 78.2%, respectively, P = .53). The median maximal diameters in the solitary and tandem groups were 6.2 and 6.7 mm, respectively. Complete occlusion on the last angiographic follow-up was achieved in 75.1% of aneurysms in the single compared with 88.6%% in the tandem group (P = .06). Symptomatic thromboembolic complications were encountered in 2.7% and 8.8% of procedures in the single and tandem groups, respectively (P = .08). CONCLUSIONS Tandem aneurysms of the ICA can be treated with a single Pipeline Embolization Device with high rates of complete occlusion. While there appeared to be a trend toward higher thromboembolic complication rates, this did not reach statistical significance.
Collapse
|
116
|
Lee WJ, Byun JS, Kim JK, Nam TK. Quantitative Computed Tomographic Volumetry after Treatment of a Giant Intracranial Aneurysm with a Pipeline Embolization Device. Yonsei Med J 2017; 58:668-671. [PMID: 28332378 PMCID: PMC5368158 DOI: 10.3349/ymj.2017.58.3.668] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2016] [Revised: 10/08/2016] [Accepted: 11/10/2016] [Indexed: 11/27/2022] Open
Abstract
Recently developed flow diverters, such as the pipeline embolization device (PED), allow for safe and efficacious treatment of giant intracranial aneurysms, with high occlusion rates and a low incidence of complications. However, incomplete obliteration after PED treatment may lead to aneurysm regrowth and delayed rupture. Herein, we report a case of a partially thrombosed giant aneurysm of the cavernous internal carotid artery that showed progressive recanalization at 1-3 months after application of a PED. We monitored inflow volume in the aneurysm by computed tomographic angiography (CTA) and computed tomographic volumetric imaging (CTVI). Based on the imaging results, rather than applying additional PED, we decided to make the switch from a dual antiplatelet medication to low-dose aspirin alone at 3 months after the treatment; complete obliteration of the aneurysm was noted at 21 months. Similar to the findings in this unusual case, CTA and CTVI may be useful follow-up methods for optimal management of patients with giant intracranial aneurysms after PED treatment.
Collapse
|
117
|
Hussein AE, Linninger A, Shakur SF, Charbel FT, Hsu CY, Charbel FT, Alaraj A. Changes in contrast transit times on digital subtraction angiography post-Pipeline Embolization Device deployment. Interv Neuroradiol 2017; 23:137-142. [PMID: 28304204 PMCID: PMC5433610 DOI: 10.1177/1591019916685892] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2016] [Revised: 11/29/2016] [Accepted: 12/02/2016] [Indexed: 11/15/2022] Open
Abstract
It is postulated that hemodynamic changes occur in the distal vascular bed post-deployment of Pipeline Embolization Devices (PEDs). In this paper, we evaluate changes in the contrast transit times (TTs) on digital subtraction angiography (DSA) post-PED interventions. DSA films were analyzed using custom-made software for the time-density relationship at baseline and compared to post-PED deployment. All analyses were performed within the middle cerebral artery (MCA) M1 segment. Analyses included TT10%-100% (time needed for the contrast to change from 10% image intensity to 100%), TT100%-10%, and TT25%-25%. Forty-four patients were included. We found a significant decrease in TT10%-100% (2.79 to 2.24 seconds, p < 0.001) post-PED. There was a significant correlation between the percentage change in TT100%-10% and aneurysm size ( p = 0.02). There was also a significant decrease in TT25%-25% (7.07 to 6.41 seconds, p = 0.02) post-PED. Moreover, there was a significant correlation between the absolute or percentage changes in TT25%-25% and aneurysm size (rho = 0.54, p = 0.05 and rho = 0.29, p = 0.05, respectively). Statistically significant distal intracranial hemodynamic changes occur post-PED deployment. These hemodynamic changes appear to be more pronounced with large and giant aneurysms.
Collapse
|
118
|
Snyderman CH, Pant H. Endoscopic Management of Vascular Sinonasal Tumors, Including Angiofibroma. Otolaryngol Clin North Am 2017; 49:791-807. [PMID: 27267026 DOI: 10.1016/j.otc.2016.02.009] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
The greatest challenge in the surgical treatment of angiofibromas is dealing with the hypervascularity of these tumors. Staging systems that take into account the vascularity of the tumor may be more prognostic. A variety of treatment strategies are used to deal with the vascularity of angiofibromas, including preoperative embolization, segmentation of the tumor into vascular territories, use of hemostatic tools, and staging of surgery. Even large angiofibromas with intracranial extension and residual vascularity can be successfully managed by a skull base team using endoscopic techniques.
Collapse
|
119
|
Nassiri N, Huntress LA. Stent-Assisted Coil Embolization of a Symptomatic Renal Artery Aneurysm at a Bifurcation Point. Ann Vasc Surg 2017; 42:299.e11-299.e14. [PMID: 28279720 DOI: 10.1016/j.avsg.2016.10.042] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2016] [Revised: 10/01/2016] [Accepted: 10/17/2016] [Indexed: 11/17/2022]
Abstract
BACKGROUND Symptomatic renal artery aneurysms at bifurcation points present challenging clinical scenarios rarely amenable to endovascular repair due to concerns regarding parenchymal loss following intervention. Herein, we add to the scant body of literature describing successful endovascular repair of a saccular, symptomatic renal artery aneurysm situated at a bifurcation point. METHODS A 52-year-old woman with a 2.5-cm extraparenchymal, saccular, symptomatic left renal artery aneurysm underwent self-expanding stent-assisted detachable platinum microcoil embolization. RESULTS Complete aneurysm exclusion was achieved with minimal parenchymal loss. There were no perioperative complications, and no evidence of acute kidney injury perioperatively or at 3-month follow-up. Sustained symptomatic relief was achieved. CONCLUSIONS Endovascular therapy can provide safe and effective aneurysm treatment within challenging bifurcated renal artery anatomy.
Collapse
|
120
|
Ishikawa H, Hara M, Ryuge M, Takafuji J, Youmoto M, Akira M, Nagasaka Y, Kabata D, Yamamoto K, Shintani A. Efficacy and safety of super selective bronchial artery coil embolisation for haemoptysis: a single-centre retrospective observational study. BMJ Open 2017; 7:e014805. [PMID: 28213604 PMCID: PMC5318547 DOI: 10.1136/bmjopen-2016-014805] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
OBJECTIVES Evidence on the safety and long-term efficacy of super selective bronchial artery embolisation (ssBAE) using platinum coils in patients with haemoptysis is insufficient. The objective of the present study was to evaluate the safety and the 3-year postprocedure haemoptysis-free survival rate of de novo elective ssBAE using platinum coils rather than particles for the treatment of haemoptysis. DESIGN A single-centre retrospective observational study. SETTING Hemoptysis and Pulmonary Circulation Center in Japan. PARTICIPANTS A total of 489 consecutive patients with massive and non-massive haemoptysis who underwent de novo elective ssBAE without malignancy or haemodialysis. INTERVENTIONS ssBAE using platinum coils. All patients underwent CT angiography before the procedure for identifying haemoptysis-related arteries (HRAs) and for procedural planning. PRIMARY AND SECONDARY OUTCOME MEASURES The composite of the 3-year recurrence of haemoptysis and mortality from the day of the last ssBAE session. Each component of the primary end point and procedural success defined as successful embolisation of all target HRAs were also evaluated. RESULTS The median patient age was 69 years, and 46.4% were men. The total number of target vessels was 4 (quartile 2-7), and the procedural success rate was 93.4%. There were 8 (1.6%) major complications: 1 aortic dissection, 2 symptomatic cerebellar infarctions and 5 mediastinal haematoma cases. The haemoptysis-free survival rates were estimated by the Kaplan-Meier analysis at 86.9% (95% CI 83.7% to 90.2%) at 1 year, 79.4% (74.8% to 84.3%) at 2 years and 57.6% (45.1% to 73.4%) at 3 years. Although not statistically significant by the adjusted analysis of variance with multiple imputation of missing variables, cryptogenic haemoptysis tended to show the most favourable outcome and non-tuberculous mycobacterium showed the worst outcome (adjusted p=0.250). CONCLUSIONS We demonstrated the safety and long-term efficacy of elective ssBAE using platinum coils and established that it can be a valuable therapeutic option for treating patients with haemoptysis.
Collapse
|
121
|
Griessenauer CJ, Gupta R, Shi S, Alturki A, Motiei-Langroudi R, Adeeb N, Ogilvy CS, Thomas AJ. Collar Sign in Incompletely Occluded Aneurysms after Pipeline Embolization: Evaluation with Angiography and Optical Coherence Tomography. AJNR Am J Neuroradiol 2017; 38:323-326. [PMID: 28056454 DOI: 10.3174/ajnr.a5010] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2016] [Accepted: 09/15/2016] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Flow diversion with the Pipeline Embolization Device has emerged as an attractive treatment for cerebral aneurysms. Processes involved in aneurysm occlusion include changes in intra-aneurysmal hemodynamics and endothelialization of the device. Here, we call attention to a radiographic sign not previously reported that is detected in incompletely occluded aneurysms after treatment with the Pipeline Embolization Device at angiographic follow-up and referred to as the "collar sign." MATERIALS AND METHODS A retrospective review of all patients who underwent placement of a Pipeline Embolization Device for cerebral aneurysms between January 2014 and May 2016 was performed. All aneurysms found to show the collar sign at follow-up were included. Optical coherence tomography was performed in 1 case. RESULTS One hundred thirty-five aneurysms were treated in 115 patients. At angiographic follow-up, 17 (10.7%) aneurysms were found to be incompletely occluded. Ten (58.8%) of these aneurysms (average diameter, 7.9 ± 5.0 mm) were found to have the collar sign at angiographic follow-up (average, 5.5 ± 1.0 months). Four (40.0%) of the aneurysms underwent a second angiographic follow-up (average, 11.0 ± 0.9 months) after treatment, and again were incompletely occluded and showing the collar sign. Two patients underwent retreatment with a second Pipeline Embolization Device. Optical coherence tomography showed great variability of endothelialization at the proximal end of the Pipeline Embolization Device. CONCLUSIONS The collar sign appears to be indicative of endothelialization, but continued blood flow into the aneurysm. This is unusual given the processes involved in aneurysm occlusion after placement of the Pipeline Embolization Device and has not been previously reported.
Collapse
|
122
|
Lin LM, Colby GP, Bender MT, Xu R, Huang J, Tamargo RJ, Coon AL. Use of the 0.027-inch VIA microcatheter for delivery of Pipeline Flex: a technical note. J Neurointerv Surg 2017; 9:689-693. [PMID: 28151413 DOI: 10.1136/neurintsurg-2016-012971] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2016] [Accepted: 01/18/2017] [Indexed: 11/03/2022]
Abstract
BACKGROUND The Pipeline Embolization Device (PED; Medtronic Neurovascular, Irvine, California, USA) is designed for delivery through a 0.027″ microcatheter. Challenges with the second-generation PED Flex include limited support from the Marksman microcatheter for consistent resheathing and transmission of push forces for device delivery. The VIA27 (Sequent Medical/MicroVention Terumo, Tustin, California, USA) is an alternative 0.027″ microcatheter originally designed for intrasaccular flow diverter delivery. Here we describe our experience with the VIA27 in the delivery of PED Flex. METHODS We retrospectively identified patients who underwent PED Flex treatment with the VIA27 microcatheter at our institution. Patient demographics, aneurysm characteristics, equipment utilized, and procedural details were documented. RESULTS A total of 127 cases were completed using the VIA27 microcatheter for PED Flex implantation. Mean patient age was 56.8±12.4 years (range 21-86 years). All but one of the cases were treatments for intracranial aneurysms. Average aneurysm size was 6.5±6 mm (range 2-38 mm). Of the 127 cases, 120 (95%) were anterior circulation cases and 7 (6%) were posterior circulation cases. Significant cervical internal carotid artery (ICA) tortuosity was present in 33/120 cases (28%). Moderate to severe cavernous ICA tortuosity was present in 54/120 cases (45%). Mean fluoroscopy time was 34.1±22.7 min. Large diameter PED devices (4.5-5 mm) were used in 42/127 cases (33%). Balloon post-processing of the PED was used in 15/127 cases (12%) to improve vessel wall apposition of the PED. CONCLUSIONS The VIA27 is a microcatheter capable of successful PED Flex delivery in neurointervention. We have shown its utility in enhancing both resheathing and push for optimal PED Flex implantation. The VIA27 microcatheter may be a useful and safe adjunct to the traditional Marksman microcatheter in PED Flex treatment of the cerebrovasculature.
Collapse
|
123
|
Lv X, Ge H, He H, Jiang C, Li Y. A systematic review of pipeline embolization device for giant intracranial aneurysms. Neurol India 2017; 65:35-38. [PMID: 28084235 DOI: 10.4103/0028-3886.198200] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
The experience with respect to the treatment of giant intracranial aneurysms with flow-diversion devices is limited. The aim of the present systematic review was to evaluate the effect of the pipeline embolization device (PED) on giant intracranial aneurysms. Eligible related articles were identified by searching the PubMed, Web of Science, Springer, ScienceDirect, and OVID databases using "giant aneurysm" and "pipeline" as the search items. The date of the last search was November 20, 2015. This systematic review adopted the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. In a total of 9 eligible studies with 200 patients and 215 aneurysms, 40 (18.6%) giant (aneurysm diameter >25mm) intracranial aneurysms treated with PED were analyzed. During a 6 to 34 month follow-up, complete occlusion was achieved in 23 (57.5%) cases. Seven patients (17.5%) developed intracranial hemorrhage, 5 developed ischemic attack (12.5%), and 13 (32.5%) developed a mass effect after PED treatment. The complication rate was 77.8% in PED for giant vertebrobasilar artery aneurysms. The cumulative mortality rate for giant paraclinoid carotid artery and middle cerebral artery aneurysms was 13.3% and increased up to 50% for giant vertebrobasilar artery aneurysms. The complete obliteration rate of PED for giant intracranial aneurysms was approximately 60%. Mass effect is the most mechanism of complications. Complication and mortality rates associated with PED for giant vertebrobasilar artery aneurysms are still extremely high.
Collapse
|
124
|
Malghem J, Abdalkader M, Lecouvet F, Goffette P, Hammer F, Vande Berg B. Pseudoaneurysms after Ankle Sprain: Report of Three Cases Successfully Cured by Nonsurgical Treatment. Ann Vasc Surg 2016; 40:296.e5-296.e13. [PMID: 27903468 DOI: 10.1016/j.avsg.2016.07.103] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2016] [Revised: 07/18/2016] [Accepted: 07/19/2016] [Indexed: 12/26/2022]
Abstract
Pseudoaneurysm is a rare complication of ankle sprain, with 18 case reports published in the current literature. In the vast majority of the cases, they were treated surgically. We present 3 cases of pseudoaneurysm following ankle sprain, treated by nonsurgical methods in 2 cases, and spontaneously healed in another. The diagnosis was made between 2 and 4 weeks after traumatism, by ultrasonography and arteriography in 2 cases, and only by ultrasonography in a third case. The pseudoaneurysms originated respectively from the perforating fibular artery, the dorsal pedis artery, and a lateral malleolar artery. Largest diameters of the pseudoaneurysms ranged from 2.4 to 6 cm. Patients were successfully treated by thrombin injection in a case and by coil embolization in another. Spontaneous thrombosis was demonstrated at follow-up in the third case. These cases suggest that a nonsurgical treatment can be considered for pseudoaneurysms complicating ankle sprains.
Collapse
|
125
|
Maleux G, Cornelissen S, Bonne L. New materials in embolizations. THE JOURNAL OF CARDIOVASCULAR SURGERY 2016; 57:750-757. [PMID: 27647339] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Percutaneous, catheter-directed embolotherapy is an established interventional technique for the management of many vascular disorders. For more than three decades, typical embolization devices included macro and microcoils, polyvinyl alcohol microparticles, glue and certain liquids such as absolute alcohol. In the past decade, however, several new embolic devices and refinements of existing embolic devices have arrived on the market and a number of clinical studies have demonstrated their added value. In this review article, these new embolic devices and their typical indications will be discussed, as well as the results of studies involving the embolic devices.
Collapse
|