Tamura A, Watanabe T, Shinozaki K, Kotoku M, Yano S, Kadota J. Comparison of sarpogrelate and ticlopidine in bare metal coronary stent implantation. Int J Cardiol 2008; 126:79-83. [PMID: 17507105 DOI: 10.1016/j.ijcard.2007.03.120] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/07/2006] [Revised: 02/19/2007] [Accepted: 03/30/2007] [Indexed: 10/23/2022]
Abstract
BACKGROUND The efficacy and safety of sarpogrelate, a selective 5-hydroxytryptamine receptor subtype 2A antagonist, have not yet been established in bare metal coronary stenting. Accordingly, we sought to clarify whether treatment with sarpogrelate is clinically useful in bare metal coronary stenting. METHODS A total of 450 patients who underwent successfully planned or unplanned bare metal coronary stenting were randomly divided into the following 2 groups: the sarpogrelate (300 mg/day) plus aspirin (100 mg/day) group (group S, n=225) and the ticlopidine (200 mg/day) plus aspirin (100 mg/day) group (group T, n=225). Either sarpogrelate or ticlopidine was administered for at least 4 weeks after the procedure. Follow-up coronary arteriography was performed at 6 months after the procedure. The primary endpoints were the incidence of adverse drug reactions requiring a withdrawal of treatment and the rate of binary restenosis. The secondary endpoint was the incidence of stent thrombosis. RESULTS The incidence of adverse drug reactions requiring a withdrawal of treatment was significantly lower in group S than in group T (0.44% vs 8%, p=0.002). The rate of binary restenosis did not differ significantly between groups S and T (16.9% vs 18.2%). In addition, the incidence of subacute stent thrombosis did not differ between groups S and T (0.44% vs 0.44%). CONCLUSIONS The incidence of adverse drug reactions requiring a withdrawal of treatment was significantly lower with sarpogrelate use than with ticlopidine use. The rate of binary restenosis and the incidence of subacute stent thrombosis did not differ between both drug groups.
Collapse
|
152
|
Campolo L, Pantaleo P, Barattoni MC, Berardo A, Ghetti L, Fusco D. [Coronary angioplasty in the real world: the RESTEM registry. Outcome of patients treated with sirolimus-eluting stents]. GIORNALE ITALIANO DI CARDIOLOGIA (2006) 2008; 9:270-279. [PMID: 18543796] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
BACKGROUND RESTEM, a prospective multicenter registry collecting all percutaneous coronary interventions made over 20 months and monitored up to 2 years, had been performed to assess, in the real world, the impact of sirolimus-eluting stents (SES) versus bare metal stents (BMS) on patients' outcomes. METHODS The registry includes 5524 consecutive patients treated with BMS (72%), SES (15%), BMS+SES (4%) or other techniques (9%). The combination of death, acute myocardial infarction, unstable angina and revascularization had been chosen as primary endpoint. RESULTS The 2-year adjusted results confirm a significant advantage of SES in target vessel revascularization (8.3 vs 13.7%, odds ratio [OR] 0.66), a benefit for overall revascularizations (18.3 vs 25.6%, OR 0.76) without reducing mortality, other clinical events and primary endpoint, therefore denying the benefit on primary endpoint observed at 12 months (18.5 vs 25.0%, OR 0.68 at 1 year and 25.8 vs 32.4%, OR 0.84 at 2 years). CONCLUSIONS RESTEM results confirm the SES capacity to reduce target vessel revascularization without decreasing other clinical events, suggest that this advantage is limited to the first 6 months after percutaneous coronary intervention, and show no evidence of excess of deaths, acute myocardial infarction and late thrombosis following SES implantation described in recent meta-analyses.
Collapse
|
153
|
Dogan A, Turker Y, Ozaydin M, Acar G, Kahraman H. Late in-stent coronary dissection in an elderly woman: An interesting case report. Int J Cardiol 2008; 125:e25-6. [PMID: 17900718 DOI: 10.1016/j.ijcard.2007.06.108] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/02/2007] [Accepted: 06/23/2007] [Indexed: 10/22/2022]
Abstract
Primary or de novo spontaneous coronary dissection has been reported in many cases; however, in-stent dissection was demonstrated in the previously stented segment of coronary artery only in an autopsy study. Therefore, we report a 78-year-old female presenting with angina pectoris and dyspnea for the last 20 days. She had undergone stent implantation for a significant stenosis in the left anterior descending artery 3 years ago. In-stent dissection flap limiting coronary flow was noted at the coronary angiography and successfully treated with coronary re-stenting. She had no symptoms at follow-up.
Collapse
|
154
|
van der Hoeven BL, Pires NMM, Warda HM, Putter H, Quax PHA, Schalij MJ, Jukema JW. Dexamethasone-eluting stents for the prevention of in-stent restenosis: Evidence for a differential effect in insulin-dependent and non-insulin-dependent diabetic patients. Int J Cardiol 2008; 124:166-71. [PMID: 17408773 DOI: 10.1016/j.ijcard.2006.12.034] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/02/2006] [Revised: 12/08/2006] [Accepted: 12/30/2006] [Indexed: 11/23/2022]
Abstract
UNLABELLED Diabetes mellitus (DM) is a strong predictor of in-stent restenosis. This may be due to a higher level of vascular inflammation. We hypothesized that diabetic patients will benefit from dexamethasone-eluting stents, since local inflammation and consequently neointimal growth are suppressed and no systemic side effects will occur. METHODS 21 consecutive patients with DM with 32 lesions were treated with dexamethasone-eluting stents. Excluded were patients with triple vessel disease, bifurcation lesions, previous revascularization of the culprit vessel, and reference diameter smaller than 2.5 or larger than 3.75 mm. MACE (death, myocardial infarction, and revascularization) was counted at 12 months. At 6 months, angiographic follow-up was performed. RESULTS Of the patients, 38% had insulin-dependent DM. Lesion type was type A/B1 in 56% and B2/C in 44%. Lesion length was 15.7+/-8.4 mm and the reference diameter was 2.83+/-0.53 mm. Event-free survival at 12 months was 62%. Any revascularization procedure was performed in 33% and target lesion revascularization in 24% of the patients. At 6 months in-stent late loss was 1.07+/-0.64 mm. Binary restenosis occurred in 28.1% of the lesions. The event-free survival in insulin-dependent DM was worse compared to non-insulin-dependent DM (92.1 vs. 37.8%; p<0.01). Patients with insulin-dependent DM had higher in-stent late loss compared to non-insulin-dependent DM patients (1.44+/-0.83 vs. 0.83+/-0.51 mm; p<0.01). CONCLUSION Treatment with dexamethasone-eluting stents in patients with DM is associated with a relatively high restenosis rate. Our data suggest a differential effect of dexamethasone-eluting stents in insulin-dependent compared to non-insulin-dependent DM.
Collapse
|
155
|
Quan WW, Lu GP, Qi WH, Li YM, Shen Y, Yuan R. Diagnostic value of magnetocardiography in patients with coronary heart disease and in-stent restenosis. Chin Med J (Engl) 2008; 121:22-26. [PMID: 18208660] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/25/2023] Open
Abstract
BACKGROUND In-stent restenosis (ISR) has become one of the most challenging problems in patients with coronary heart disease. At present, using non-invasive methods to assess ISR is a hot topic. In this investigation we attempted to explore the potential of magnetocardiography (MCG) in diagnosis of in-stent restenosis. METHODS MCG was analyzed in 52 patients with coronary artery disease for three times: before stenting, one month and 7 months after successful intracoronary stenting. RESULTS The average classification of total maps (ACTM) and the ratio of abnormal maps (RAM) were lower in 1 month after intracoronary stenting compared with that obtained before stent planting (2.91 vs 2.52, 65.74% vs 42.80%, P < 0.01), while complex ventricular excitation index (CVEI) increased from -42.63 to -20.05 (P < 0.01). In ISR subgroup (n = 16), RAM decreased in 1 month after intracoronary stenting compared to it before stenting (68.99% vs 45.26%, P < 0.05). ACTM increased in 7 months compared to that obtained in 1 month after stenting (3.15 vs 2.51, P < 0.05). According to the ROC curve, ACTM showed its unique diagnostic value in restenosis patients. The sensitivity and specificity of ACTM were 80.0%, 69.40%, respectively. Its positive predictive value and negative predictive value were 54.6% and 88.5%, respectively. CONCLUSIONS After successful intracoronary stenting, most parameters of MCG were improved. ACTM was of prognostic value in diagnosing ISR.
Collapse
|
156
|
Fu Q, Li ZL, Wu HC. [Efficacy and safety of implantation of multiple drug-eluting stents]. NAN FANG YI KE DA XUE XUE BAO = JOURNAL OF SOUTHERN MEDICAL UNIVERSITY 2008; 28:110-112. [PMID: 18227039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
OBJECTIVE To assess the efficacy and safety of implantation of multiple drug-eluting stents. METHODS A retrospective study of 151 cases was conducted, including 34 with implantation of at least 3 drug-eluting stents in the coronary artery (MS group), 53 with implantation of two stents (TS group), and 64 with a single stent (OS group). The incidence of major adverse cardiovascular event (MACE) and restenosis was evaluated. RESULTS No significant difference was found between the 3 groups in the incidence of MACE or in the stent thrombosis rate 30 days after the implantation. Follow-up of the patients for 6 months still showed comparable restenosis rate and MACE incidence between the 3 groups. CONCLUSION Implantation of multiple drug-eluting stents does not increase the risk of restenosis or MACE, and has comparable safety and efficacy with implantation of single and two stents.
Collapse
|
157
|
Lewandowski M, Kornacewicz-Jach Z, Millo B, Zielonka J, Czechowska M, Kaliszczak R, Płońska E, Goracy J, Kaźmierczak J, Naruszewicz M. The influence of low dose atorvastatin on inflammatory marker levels in patients with acute coronary syndrome and its potential clinical value. Cardiol J 2008; 15:357-364. [PMID: 18698545] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/26/2023] Open
Abstract
BACKGROUND High-dose statins are used in acute coronary syndromes (ACS) to reduce inflammation. The aim of the study was the evaluation of the influence of low-dose atorvastatin (20 mg) on selected inflammatory parameters and clinical outcomes after ACS. METHODS Seventy eight patients (pts) with ACS were randomly divided into group A (39 pts) taking atorvastatin, and group NA (39 pts) not taking any statin for the following six weeks. C-reactive protein (CRP), interleukin-6 (IL-6), monocyte chemoattractant protein-1 (MCP-1) and tumour necrosis factor alpha (TNFa) levels were measured on the first and the fifth days and six weeks after ACS. RESULTS There was no significant CRP and IL-6 level decrease in group A (CRP--62%; IL-6-73%) or group NA (CRP-44%; IL-6-62%). There was also no significant change in TNFa levels. The MCP-1 level finally reached the level of significant difference (p < 0.04). Cardiovascular events (MACE) and the restenosis rates did not differ between the groups. CONCLUSIONS Low-dose atorvastatin does not have a significant influence on cooling down inflammation in ACS, and MCP-1 can be used as an early indicator of statin anti-inflammatory activity. Furthermore, it does not reduce MACE or restenosis rates despite its influence on MCP-1 levels.
Collapse
|
158
|
Ponnuthurai FA, van Gaal WJ, Channon KM. Focal in-stent restenosis and in-stent thrombosis within the same bare-metal stent 5 years after deployment in a saphenous vein graft. THE JOURNAL OF INVASIVE CARDIOLOGY 2007; 19:E369-E371. [PMID: 18180530] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Complications of percutaneous coronary intervention include in-stent restenosis (ISR) and in-stent thrombosis (IST) which have different underlying pathophysiological processes and different treatment strategies. ISR is primarily due to excessive neointimal growth and occurs in 20-30% of bare-metal stents (BMS). Drug-eluting stents (DES) have decreased the rates of ISR (< 10%), but are potentially associated with increased IST related to delayed arterial healing and stent strut exposure. ISR of BMS typically occurs within 6 months of stent deployment. IST usually occurs within 12 months of DES deployment. We present a case of focal ISR and IST within the same BMS, confirmed with intravascular ultrasound, 5 years after deployment in a saphenous vein graft.
Collapse
|
159
|
Hsieh NK, Chen HI. Interacting leukocytes predict atherosclerosis and restenosis. Stroke 2007; 38:e162-3; discussion e160-1. [PMID: 17975100 DOI: 10.1161/strokeaha.107.496455] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
160
|
Hou RT, Hao ZM, Ding ZJ, Jin FB, Guo DJ, Li CH. [Association of QT dispersion, ST/heart rate slope and ST-segment depression in exercise test to evaluate restenosis after percutaneous coronary intervention]. ZHONGGUO WEI ZHONG BING JI JIU YI XUE = CHINESE CRITICAL CARE MEDICINE = ZHONGGUO WEIZHONGBING JIJIUYIXUE 2007; 19:671-674. [PMID: 17996135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
OBJECTIVE To evaluate the sensitivity and specificity of QT dispersion (QTd) and ST/heart rate slope (ST/HRs) at the end of ECG exercise test plus ST-segment depression on diagnosing restenosis after percutaneous coronary intervention (PCI). METHODS Between November 2001 and December 2003, 129 patients underwent PCI successfully, and they were examined 3-6 months later. At the end of treadmill exercise, QTd and ST/HRs were measured. All patients also accepted coronary angiography to ascertain whether he/she had restenosis. The results of QTd and ST/HRs plus ST-segment depression were then evaluated. RESULTS The sensitivity and specificity of QTd and ST/HRs plus ST-segment depression were 84.6% and 80.4% respectively. Both of them were significantly higher than conventional ST-segment depression standard (sensitivity was 53.3% and specificity was 66.7%, P<0.05). CONCLUSION Measuring QTd and ST/HRs at the end of ECG treadmill exercise test plus ST-segment depression can be used for the diagnosis of restenosis after PCI.
Collapse
|
161
|
Hamon M, Champ-Rigot L, Morello R, Riddell JW, Hamon M. Diagnostic accuracy of in-stent coronary restenosis detection with multislice spiral computed tomography: a meta-analysis. Eur Radiol 2007; 18:217-25. [PMID: 17763854 DOI: 10.1007/s00330-007-0743-6] [Citation(s) in RCA: 56] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2007] [Revised: 05/27/2007] [Accepted: 07/20/2007] [Indexed: 11/24/2022]
Abstract
This study was designed to define the current role of multislice spiral computed tomography (MSCT) for the diagnosis of coronary in-stent restenosis using a meta-analytic process. Restenosis remains a limitation after coronary stent implantation and contributes to a substantial number of coronary re-assessments by conventional invasive coronary angiography (CA). We identified 15 studies (807 patients) evaluating in-stent restenosis by means of both MSCT (>or=16 slices) and conventional CA until February 2007. After data extraction the analysis was performed according to a random-effects model. The analysis pooled the results from 15 studies with a total of 1,175 stents. A substantial number of unassessable stents (13%) were excluded from the analysis underscoring the shortcomings of MSCT. With this major limitation the diagnostic performance of MSCT for in-stent restenosis detection can be summarized as follows: the sensitivity and specificity were 84% [95% confidence interval (CI) 77-89%] and 91% (95% CI 89-93%), respectively, with positive and negative likelihood ratios of 12.2 (95% CI 6.6-22.6) and 0.23 (95% CI 0.17-0.31), respectively, and with a diagnostic odds ratio of 67.9 (95% CI 34.4-134.1). MSCT has shortcomings difficult to overcome in daily practice for in-stent restenosis detection and continues to have moderately high sensitivity and specificity. The diagnostic role of this emerging technology as an alternative to CA for in-stent restenosis detection remains limited.
Collapse
|
162
|
Schwartz RS. Ionizing radiation and the coronary arteries: the plot is thickening! Catheter Cardiovasc Interv 2007; 70:366-7. [PMID: 17722040 DOI: 10.1002/ccd.21321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
163
|
Lee SH, Park JS, Shin DG, Kim YJ, Hong GR, Kim W, Shim BS. Frequency of stent fracture as a cause of coronary restenosis after sirolimus-eluting stent implantation. Am J Cardiol 2007; 100:627-30. [PMID: 17697818 DOI: 10.1016/j.amjcard.2007.03.073] [Citation(s) in RCA: 70] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2007] [Revised: 03/15/2007] [Accepted: 03/15/2007] [Indexed: 10/23/2022]
Abstract
Stent fracture (SF) was suggested as a cause of restenosis after sirolimus-eluting stent (SES) implantation. This study was performed to evaluate the incidence and characteristics of SF to determine its contribution to restenosis in patients with in-stent restenosis (ISR) after SES implantation. From May 2003 to February 2006, SESs were used for percutaneous coronary intervention in 868 patients with 1,109 coronary narrowings. Follow-up coronary angiography was performed in 366 patients (42%), and 26 ISR lesions were observed. These patients were enrolled in this study. SF was divided into 3 types as avulsion, collapse, and partial based on the findings of fluoroscopy, coronary angiography, and intravascular ultrasound study. Of 26 patients with ISR lesions, SF was identified in 10. SF types were avulsion (5 patients), collapse (2 patients), and partial (3 patients). SF was identified at the midshaft (7 patients) and overlap sites (3 patients) of stents. SF was not observed in the 30 patients with ISR after bare-metal Bx Velocity stent implantation. Four patients with SF were treated with paclitaxel-eluting stents. In conclusion, SF is 1 of the leading causes of ISR after SES implantation. Careful fluoroscopic examination is necessary at the time of follow-up angiography to identify this problem.
Collapse
|
164
|
Escolar E, Mintz GS, Popma J, Michalek A, Kim SW, Mandinov L, Koglin J, Stone G, Ellis SG, Grube E, Dawkins KD, Weissman NJ. Meta-analysis of angiographic versus intravascular ultrasound parameters of drug-eluting stent efficacy (from TAXUS IV, V, and VI). Am J Cardiol 2007; 100:621-6. [PMID: 17697817 DOI: 10.1016/j.amjcard.2007.03.076] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/31/2006] [Revised: 03/04/2007] [Accepted: 03/20/2007] [Indexed: 11/27/2022]
Abstract
Both quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS) are currently used to assess in-stent restenosis. This study aimed to use standardized imaging and clinical follow-up to compare QCA parameters with several IVUS parameters to evaluate their strengths and weaknesses for detecting in-stent restenosis in a drug-eluting stent population. A subset of patients from the TAXUS IV, V, and VI studies was evaluated. The subset, which included 216 TAXUS-treated patients and 191 bare-metal stent-treated patients, had complete IVUS and QCA performed at baseline and follow-up. As expected, all QCA and IVUS parameters were consistent with less intimal hyperplasia in TAXUS patients than controls. The overall incidence of QCA binary restenosis was 14.0%, which was 9.3% in TAXUS-treated patients and 19% in bare-metal stent-treated patients (p = 0.0008). Regression analysis showed that QCA late lumen loss and percentage of diameter stenosis correlated only moderately with the various IVUS measures of neointimal hyperplasia for the combined group of patients (TAXUS + bare-metal stent), as well as for the TAXUS-treated and bare-metal stent-treated patients separately. However, in general, correlations within the control (bare-metal stent) group tended to be stronger than within the TAXUS group. The strongest correlation was between QCA percentage of diameter stenosis and IVUS percentage of intimal hyperplasia in the overall group and the control group. The strongest IVUS predictor of QCA binary restenosis at 9 months was maximum percentage of intimal hyperplasia, with an overall C = 0.91 and p <0.001. In conclusion, the QCA and IVUS parameters used to evaluate drug-eluting stent efficacy showed a moderate correlation with IVUS percentage of intimal hyperplasia, reliably predicting QCA binary in-stent restenosis.
Collapse
|
165
|
Murasaki K, Kawana M, Murasaki S, Tsurumi Y, Tanoue K, Hagiwara N, Kasanuki H. High P-selectin expression and low CD36 occupancy on circulating platelets are strong predictors of restenosis after coronary stenting in patients with coronary artery disease. Heart Vessels 2007; 22:229-36. [PMID: 17653516 DOI: 10.1007/s00380-006-0966-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/27/2006] [Accepted: 12/01/2006] [Indexed: 10/23/2022]
Abstract
Recent studies have shown that circulating platelets play an important role in the development of restenosis early after coronary stent implantation. We investigated P-selectin expression and CD36 blockade on platelets by flow cytometry in 48 consecutive patients who underwent coronary stenting. P-selectin expression was significantly higher 1 day after stenting in patients who had restenosis (n = 15) than in those who had no restenosis (n = 28), and the odds ratio for restenosis in patients with high P-selectin levels (MFI > 6.5) was 11.67 (P < 0.001) as compared with patients who had intermediate and low P-selectin levels. CD36 blockade was assessed with the use of two anti-CD36 antibodies, OKM5 and GS95 (our new anti-CD36 antibody), the binding of which indicates total CD36 amount and free CD36 unoccupied by lipid-related ligands, respectively. Binding of OKM5 to platelets was similar before and after stenting in both groups. CD36 blockade on platelets was seen 1 day after stenting in the non-restenosis group, and the odds ratio for restenosis in patients without CD36 blockade [GS95 binding ratio >0.8 as compared with binding before stenting] on day 1 was 28.60 (P < 0.001). P-selectin expression and unoccupied CD36 on platelets shortly after stenting may be strong predictors of post-stent restenosis.
Collapse
|
166
|
Kotooka N, Inoue T, Fujimatsu D, Morooka T, Hashimoto S, Hikichi Y, Uchida T, Sugiyama A, Node K. Pentraxin3 is a novel marker for stent-induced inflammation and neointimal thickening. Atherosclerosis 2007; 197:368-74. [PMID: 17640648 DOI: 10.1016/j.atherosclerosis.2007.05.031] [Citation(s) in RCA: 64] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/23/2007] [Revised: 05/08/2007] [Accepted: 05/30/2007] [Indexed: 11/17/2022]
Abstract
Inflammation in the injured vessel wall plays an essential role in the mechanism of restenosis. Pentraxin3 (PTX3) is synthesized at the inflammatory site in response to primary inflammatory stimuli. To establish the clinical significance of plasma PTX3 levels in the pathophysiology of inflammation in the injured vessels, we serially measured the levels in 20 patients undergoing elective coronary stenting. Plasma PTX3 levels increased 15 min after coronary stenting, and reached a maximum at 24h in the coronary sinus (P<0.001 versus baseline) and peripheral blood (P<0.001 versus baseline). The transcardiac gradient of PTX3 at 15 min after PCI was higher in patients with than those without restenosis (0.40+/-0.64 versus -0.19+/-0.33 ng/ml, P=0.02). Furthermore, the increase in PTX3 at 24h was positively correlated with the increase in activated Mac-1 on the surface of neutrophils at 48 h (r=0.48, p<0.05) in the coronary sinus. Stepwise multiple regression analysis demonstrated that the relative increase in PTX3 at 24h was the most powerful predictor of late lumen loss (r=0.547, P=0.007). Coronary stenting enhanced circulating PTX3 levels in association with an inflammatory response. PTX3 may be a useful marker for evaluation of inflammatory reaction and neointimal thickening after vascular injury.
Collapse
|
167
|
Sheth T, Dodd JD, Hoffmann U, Abbara S, Finn A, Gold HK, Brady TJ, Cury RC. Coronary stent assessability by 64 slice multi-detector computed tomography. Catheter Cardiovasc Interv 2007; 69:933-8. [PMID: 17421013 DOI: 10.1002/ccd.21130] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND We evaluated the assessability of contemporary stent platforms by 64-slice multi-detector computed tomography (MDCT). METHODS Patients undergoing coronary stenting were included in a prospective protocol of MDCT imaging within 48 hr of stent implantation. MDCT data were acquired using a "Sensation 64" MDCT scanner (Siemens Medical Solutions, Forchheim, Germany). Stent assessability was assessed by two independent blinded observers and disagreement was resolved by a third observer. Assessability was defined at visualization of the in-stent lumen without influence of partial volume effects, beam hardening, motion, calcification, or contrast to noise limitations. RESULTS Fifty four stents (Cypher n = 25, Vision/Minivision n = 19, Taxus Express n = 8, Liberte n = 1, Driver n = 1) in 44 patients were included in the study. The two independent observers classified 30 of 54 stents (56%) as assessable. Interobserver reproducibility was good with kappa = 0.66. Stent size was the most important determinant of assessability. Consistently assessable stents were 3.0 mm or larger (85%), whereas those under 3 mm were mostly nonassessable (26%). CONCLUSIONS Contemporary stent designs evaluated on a 64-slice MDCT scanner showed artifact free assessability only in larger stents. Increase in spatial resolution of MDCT scanners or modifications in stent design will be necessary to noninvasive evaluate stents <3 mm in diameter, where in-stent restenosis is more frequent.
Collapse
|
168
|
Lell MM, Panknin C, Saleh R, Sayre JW, Schmidt B, Dinh H, Ruehm SG. Evaluation of Coronary Stents and Stenoses at Different Heart Rates With Dual Source Spiral CT (DSCT). Invest Radiol 2007; 42:536-41. [PMID: 17568277 DOI: 10.1097/rli.0b013e318041f674] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
OBJECTIVES Evaluation of coronary arteries at higher heart rates and in the presence of coronary stents remains problematic. The utilization of dual source computed tomography (DSCT) might improve the visualization of the coronary arteries under these conditions by imaging at a temporal resolution of 83 milliseconds, independent of heart rate. MATERIALS AND METHODS Vessel phantoms (diameter 2-4 mm) were attached to a robotic device to simulate cardiac motion and scanned with a DSCT system. The phantoms had either inserts leading to 50% stenosis or carried stents. Images were evaluated for motion artifacts and measurements of the normal, stenotic, and in-stent lumen at different heart rates (50-120 bpm) were performed. Quantile regression analysis was performed to investigate heart rate dependence of the measurement errors. RESULTS Visualization of the stenoses and stents was possible without motion artifacts at heart rates of up to 120 bpm. Image quality was similar for the static (0 bpm) and the dynamic (50-120 bpm) scans. Errors for diameter measurements of the vessel lumen and the stenotic lumen were low (3-mm vessel: 1-2%), but considerable for in-stent diameter measurements (3-mm stent: 27-32%). A window/level setting of 1500/300 Hounsfield units was more favorable for stent evaluation. No heart rate dependence was found. CONCLUSIONS Depiction of coronary stents with DSCT is possible across a large range of simulated heart rates without motion artifacts and with image quality superior to that of previous generations of CT scanners.
Collapse
|
169
|
Yamawaki T, Yamada A, Fukumoto Y, Kishi T, Sobashima A, Kuwata K, Nakamura R, Sekiya M, Ando H, Okamatsu S. Statin therapy may prevent restenosis after successful coronary intervention, independent of lipid-lowering effect and CRP level. FUKUOKA IGAKU ZASSHI = HUKUOKA ACTA MEDICA 2007; 98:260-9. [PMID: 17665547] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
BACKGROUND As statins have the anti-atherosclerotic pleiotropic effects, we retrospectively examined the effects of statins on restenosis after percutaneous coronary intervention (PCI). METHODS We reviewed consecutive 341 patients who underwent successful PCI and follow-up angiography six months after the procedure between January 2002 and December 2004. Statins were initiated in 207 patients (statin group), but not in the other 134 (control group). We compared the angiographic findings, low-density lipoprotein cholesterol (LDL-C) and C-reactive protein (CRP) between the two groups. RESULTS LDL-C level in statin group was significantly higher than those in control group at baseline (116.0 +/- 35.8 vs 103.1 +/- 24.5 mg/dL, p < 0.01); however, the values were inverted between the two groups at follow-up (99.9 +/- 29.5 vs 107.6 +/- 26.0 mg/dL, p = 0.015). CRP levels were comparable between these two groups. Statin group showed significantly lower angiographic restenosis (defined as > or = 50% stenosis at the target site) rate (35.3 vs 46.3%, p = 0.042) and target lesion revascularization (TLR) rate (14.5 vs 23.9%, p = 0.018) than control group. Multivariate analysis indicated that the prescription of statin, but not LDL-C level at follow-up and % reduction of LDL-C during the follow-up period, predict the restenosis prevention. CONCLUSIONS Statins can decrease restenosis and TLR rate after PCI, independent of lipid-lowering effect and CRP level in this study.
Collapse
|
170
|
Gupta R, Raffel OC, Jang IK. Severe intimal hyperplasia after sirolimus eluting stent deployment: evaluation by optical coherence tomography. Heart 2007; 93:754. [PMID: 17502657 PMCID: PMC1955168 DOI: 10.1136/hrt.2006.091918] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
171
|
Jaster M, Horstkotte D, Willich T, Stellbaum C, Knie W, Spencker S, Pauschinger M, Schultheiss HP, Rauch U. The amount of fibrinogen-positive platelets predicts the occurrence of in-stent restenosis. Atherosclerosis 2007; 197:190-6. [PMID: 17485094 DOI: 10.1016/j.atherosclerosis.2007.03.020] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2006] [Revised: 03/12/2007] [Accepted: 03/13/2007] [Indexed: 11/24/2022]
Abstract
AIMS To determine the value of fibrinogen-positive platelet-analysis in predicting restenosis after stent implantation in acute myocardial infarction patients. METHODS AND RESULTS Our patient population comprised 50 patients who underwent intravascular ultrasound (IVUS) guided stent implantation for acute myocardial infarction. In all cases, IVUS confirmed a deep vessel wall injury due to a ruptured plaque within the culprit lesion. Flow cytometry quantified the amount of platelets with surface-bound fibrinogen and thrombospondin before and immediately after the intervention. After 5 months, IVUS was repeated to assess the long-term results. In-stent restenosis - defined as a percent diameter stenosis of >50% - was detected in 11 of 45 patients who attended follow-up angiography. The amount of fibrinogen-positive platelets was significantly higher among patients who subsequently developed in-stent restenosis (50.5+/-6.8% fibrinogen-positive platelets immediately after intervention) than among those who did not (39.7+/-12.3% fibrinogen-positive platelets, p<0.005). Receiver operating characteristic curve revealed a 40% cut-off for fibrinogen-positive platelets immediately after the intervention to predict restenosis (p<0.05, sensitivity: 90.9%, specificity: 47.1%). CONCLUSION The amount of fibrinogen-positive platelets immediately after stent implantation predicts the occurrence of in-stent restenosis, as confirmed by IVUS in acute myocardial infarction patients.
Collapse
|
172
|
|
173
|
Jin X, Zhang S, Xie H, Wang C, Fan Z, Zeng Y, Shen Z, Fang Q. Strut fracture of DES: An increasing problem? Int J Cardiol 2007; 118:e54-6. [PMID: 17395294 DOI: 10.1016/j.ijcard.2006.12.064] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/12/2006] [Accepted: 12/31/2006] [Indexed: 11/21/2022]
Abstract
Drug-eluting stents (DES) have greatly reduced the possibility of in-stent restenosis by inhibiting neointimal growth. But recently stent fracture has emerged as a complication. Stent fracture may cause restenosis, even occlusion. Here we report a case of stent fracture after percutaneous coronary intervention with DES without restenosis.
Collapse
|
174
|
Lindsay J, Sharma AK, Canos D, Nandalur M, Pinnow E, Apple S, Ruotolo G, Wijetunga M, Waksman R. Preprocedure hyperglycemia is more strongly associated with restenosis in diabetic patients after percutaneous coronary intervention than is hemoglobin A1C. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2007; 8:15-20. [PMID: 17293264 DOI: 10.1016/j.carrev.2006.10.002] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2006] [Accepted: 10/11/2006] [Indexed: 11/17/2022]
Abstract
BACKGROUND Although more frequent in diabetic patients, restenosis after percutaneous coronary intervention (PCI) is less common in those with good glycemic control. High circulating insulin levels may also be associated with more frequent restenosis. METHODS Fasting blood samples were obtained from 162 diabetic patients immediately prior to the PCI and analyzed for glucose, hemoglobin A1C, and insulin. Nine-month follow-up information was obtained in 145 (89.5%) patients. Target vessel revascularization (TVR) was the surrogate for restenosis. RESULTS Patients were divided into quartiles with regard to their blood levels. Insulin, calculated insulin resistance, and hemoglobin A1C were not associated with increased TVR rates. Glucose level was significantly associated (P=.02). Patients in the two lower quartiles (glucose < or = 128 mg/dl) had a 9-month TVR rate of 12.7% while those in the two higher quartiles (>128 mg/dl) had a rate of 33.8% (P=.005). Level of glucose was independent of hemoglobin A1C. In patients whose A1C level was < or = 7%, the TVR rate was greater in those with a glucose level >128 mg/dl (39.1% vs. 10.6%, P=.009). Similarly, in patients with a hemoglobin A1C level >7%, the TVR rate was lower in patients with a glucose level < or = 128 mg/dl, but this difference did not reach statistical significance (16.6% vs. 31.3%, P=.3). CONCLUSIONS Hemoglobin A1C, insulin, and insulin resistance at the time of the PCI are not associated with restenosis. Periprocedural hyperglycemia may promote restenosis in diabetics.
Collapse
|
175
|
Martuscelli E, Razzini C, D'Eliseo A, Di Luozzo M, Mauro B, Romeo F. In-stent restenosis and multislice computed tomography: is the method ready to start? J Cardiovasc Med (Hagerstown) 2007; 8:377-80. [PMID: 17443107 DOI: 10.2459/01.jcm.0000268130.82037.43] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
We present two patients revascularized by coronary stents and evaluated by multislice computed tomography (CT). In first patient, angio-CT (16 slices/rotation scanner) detected a high-grade restenosis on the distal part of a drug-eluting stent; conventional coronary angiography confirmed the diagnosis. In second patient, angio-CT (64 slices/rotation) showed a tissue proliferation, non-flow-limiting, in the proximal part of a bare metal stent; conventional angiography confirmed the diagnosis. Blooming effects and partial volume averaging still limit the widespread application of this method. New scanners and the use of a special convolution kernel are likely to improve the accuracy of CT angiography in patients with stents.
Collapse
|