1
|
Castiello E, Bruschi A, Bordini B, De Gaetano F, Tigani D. The Avantage ® dual mobility cup in primary total hip arthroplasty: A registry study. J Orthop 2024; 56:98-102. [PMID: 38828468 PMCID: PMC11137359 DOI: 10.1016/j.jor.2024.05.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/24/2024] [Accepted: 05/10/2024] [Indexed: 06/05/2024] Open
Abstract
Background Avantage Cup has been widely used in dual mobility implants. However, in Swedish Registry, the outcome of the Avantage Cup is reported with higher implants revision compared to control. The aim of our study was to verify if the same results are present in the Registry of Prosthetic Orthopedic Implants (RIPO) of Emilia Romagna (ER, Italy), as the Avantage cup was the most implanted dual mobility cup for a long follow-up reported in this Registry (2000-2012). Furthermore, we assessed the survival rate of the implant over the time. Methods We included all patients that underwent a primary THA using the Avantage cup during the period 2000-2020 in RIPO Registry. The survivorship of the primary THA implants was calculated and plotted according to Kaplan-Meier method. Results 886 Avantage cups were included in the analysis. During the observational period 44 hips were revised. The most common reasons for revision were: periprosthetic fractures (PPF) (n = 7, 0.8 %), deep infection (n = 7, 0.8 %), and cup aseptic loosening (n = 13, 1.5 %).The survival rate of the implant was 96.8 % (95.3-97.8) at 5 years, 95.7 at 10 years (94.0-97.0) and 92.1 at 15 years (88.5-94.6). Conclusion In conclusion, this study has demonstrated that the Avantage cup in primary hip arthroplasty implanted with a "friendly" femoral stem granted satisfactory long-term survival. Therefore, in the Swedish Registry, the cause of the poor results presented for Avantage Cup could be the thick, rough neck stem of the widely used Lubinus stem.
Collapse
Affiliation(s)
- E. Castiello
- Department of Orthopaedic Surgery Ospedale Maggiore “Carlo Alberto Pizzardi”, Largo Nigrisoli 2, 40133, Bologna, Italy
| | - A. Bruschi
- Department of Biomedical and Neuromotor Science-DIBINEM, IRCCS Rizzoli Orthopaedic Institute, University of Bologna, Via Zamboni 33, 40125, Bologna, Italy
| | - B. Bordini
- Medical Technology Laboratory, IRCCS – Rizzoli Orthopaedic Institute, Via di Barbiano 1/10, 40136, Bologna, Italy
| | - F. De Gaetano
- Medical Technology Laboratory, IRCCS – Rizzoli Orthopaedic Institute, Via di Barbiano 1/10, 40136, Bologna, Italy
| | - D. Tigani
- Department of Orthopaedic Surgery Ospedale Maggiore “Carlo Alberto Pizzardi”, Largo Nigrisoli 2, 40133, Bologna, Italy
| |
Collapse
|
2
|
Klein A, Bordes M, Viste A, Fessy M. Dual-mobility tripod cup for revision hip arthroplasty: long-term (five to fourteen years) evaluation of a new generation cementless implant. INTERNATIONAL ORTHOPAEDICS 2024; 48:1241-1247. [PMID: 38499712 DOI: 10.1007/s00264-024-06144-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Accepted: 03/06/2024] [Indexed: 03/20/2024]
Abstract
PURPOSE The aims of this study were to evaluate the survivorships of a new generation cementless DMC with tripod additional fixation in revision total hip arthroplasty and complications at a minimum five year follow-up. METHODS One hundred and fifteen revisions (THA) treated with tripod DMC performed between 2009 and 2015 were included in this retrospective study. Acetabular defects were classified as Paprosky 1 (n = 38, 33%), 2 (n = 75, 65%) or 3 (n = 2, 2%). Unipolar or bipolar revision was performed for the following indications: aseptic acetabular loosening (63%), infection (14%), aseptic bipolar loosening (11%), instability (4%), aseptic femoral loosening (3%), ALVAL (3%) and iliopsoas impingement (2%). Mean follow-up was 9.4 years ± two (range, 5 to 14). RESULTS At the final follow-up, a single episode of dislocation occurred within three months after the procedure (0.8%) with no revision. Three cases of aseptic loosening were diagnosed (2.6%). Four infections (3.5%) required reoperation: three required a two stage bipolar revision; one was treated by DAIR procedure. At the latest follow-up, the survivorship of the acetabular cup for aseptic loosening was 98% [95% CI (91.2-99.4)] and for any reasons was 94.4% [95% CI (90.1%-98.9%)]; the mean HHS improved from 60 points (range, 18-94 points) to 83 points (range, 37-100 points) (p < .001). CONCLUSION This study reports a low complication rate in favour of the use of a tripod DMC in revision THA with a satisfactory survivorship at a ten year follow-up.
Collapse
Affiliation(s)
- Aurélien Klein
- Hospices Civils de Lyon, Hôpital Lyon Sud, Chirurgie Orthopédique Et Traumatologique, 165 Chemin du Grand Revoyet, 69495, Pierre Benite Cedex, France
| | - Maxence Bordes
- Hospices Civils de Lyon, Hôpital Lyon Sud, Chirurgie Orthopédique Et Traumatologique, 165 Chemin du Grand Revoyet, 69495, Pierre Benite Cedex, France
| | - Anthony Viste
- Hospices Civils de Lyon, Hôpital Lyon Sud, Chirurgie Orthopédique Et Traumatologique, 165 Chemin du Grand Revoyet, 69495, Pierre Benite Cedex, France.
- Univ Lyon, Univ Gustave Eiffel, Univ Claude Bernard Lyon 1, LBMC UMR_T9406, 69622, Lyon, France.
| | - Michel Fessy
- Hospices Civils de Lyon, Hôpital Lyon Sud, Chirurgie Orthopédique Et Traumatologique, 165 Chemin du Grand Revoyet, 69495, Pierre Benite Cedex, France
- Univ Lyon, Univ Gustave Eiffel, Univ Claude Bernard Lyon 1, LBMC UMR_T9406, 69622, Lyon, France
| |
Collapse
|
3
|
Hitz O, Le Baron M, Jacquet C, Argenson JN, Parratte S, Ollivier M, Flecher X. Use of dual mobility cup cemented into a tantalum acetabular shell for hip revision with large bone loss can decrease dislocation risk without increasing the risk of mechanical failure. Orthop Traumatol Surg Res 2024; 110:103739. [PMID: 37918693 DOI: 10.1016/j.otsr.2023.103739] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Revised: 08/17/2023] [Accepted: 08/28/2023] [Indexed: 11/04/2023]
Abstract
BACKGROUND Porous tantalum components and augments have demonstrated short to midterm fixation stability in acetabular total hip arthroplasty (THA) revision but do not offer a novel option to decrease the postoperative dislocation rate. Recently, dual mobility (DM) cups have gained interest to decrease the prevalence of recurrent hip instability after revision hip arthroplasty, but this issue was not confirmed combined with use of tantalum reconstruction devices. Therefore, we did a retrospective study aiming to: (1) evaluate at a 5-year minimum follow-up period the dislocation rate (and other intra- and postoperative complications), (2) assess radiographic results specifically looking at osseointegration and restoration of the hip center, (3) and also clinical results in a cohort of patients who underwent complex acetabular reconstruction with trabecular metal revision components associated with a cemented DM socket. HYPOTHESIS Using a DM socket cemented in porous tantalum components can reach the low risk of hip dislocation reported with DM components in revision setting without increasing the risk of a mechanical failure. METHODS A cross-sectional study identified 174 THA revision including an acetabular revision. Were excluded 118 revisions with acetabular defects Type 1, 2a or 2B according to Paprosky's classification, as well as 18 hips revised without a dual mobility and 3 patients (3 hips) lost to follow-up. Were thus included in this study 35 hips (35 patients) implanted with uncemented total hip arthroplasty revision using both trabecular metal acetabular cup-cage reconstruction and a cemented DM cup. Seven hips were classified Paprosky types 2C, 15 type 3A and 13 types 3B. Patients were followed with clinical and radiological evaluation regarding dislocation rate, infection, reoperation or re-revision, osseointegration and restoration of the hip center, and functional results according to the Harris hip score and psoas impingement presence. RESULTS At a mean follow-up of 8.1±1.8 years (5.1-12.6), one dislocation was recorded, and one acute deep infection. No patient required a cup re-revision for septic or aseptic loosening. The survivorship at 8years regarding revision for any cause as an endpoint was 96.5% (CI95%: 92-99). Osseointegration of TM implants was analyzed and found no acetabular migration at the last follow-up in the cohort. The mean hip center position was optimized from 48±7mm (37-58) to 34±5mm (29-39) vertically and from 26±5mm (-18-36) to 24±8mm (7-31) horizontally without reaching significance (p=0.1). On the last follow-up X-rays, the mean acetabular inclination was 47̊±9̊ (32̊-61̊). According to the criteria of Hirakawa, 97.1% (34/35) of the hip centers were restored. One cup (2.9%) was more than 5mm proximally from the hip center, and none more than 10mm. Clinical results assessed a Harris Hip Score improved from 36±17 (23-62) preoperatively to 82±15 (69-93) at last follow-up (p<0.0001). Two patients (2/35, 5.7%) complained of psoas impingement. CONCLUSION This study suggests effectiveness of DM cups in association with a tantalum-made acetabular shell for reconstruction of large bone defect in THRs for both solving postoperative instability and aseptic loosening without increasing the re-revision rate for any reason in a midterm follow-up. LEVEL OF EVIDENCE IV; observational study.
Collapse
Affiliation(s)
- Olivier Hitz
- Clinique des Vergers, chemin de la Planche 1, 1217 Meyrin, Switzerland
| | - Marie Le Baron
- Institut du Mouvement et de l'appareil locomoteur, Aix Marseille Université - Assistance publique des Hôpitaux de Marseille, 270, boulevard Sainte-Marguerite, 13009 Marseille, France
| | - Christophe Jacquet
- Institut du Mouvement et de l'appareil locomoteur, Aix Marseille Université - Assistance publique des Hôpitaux de Marseille, 270, boulevard Sainte-Marguerite, 13009 Marseille, France
| | - Jean-Nöel Argenson
- Institut du Mouvement et de l'appareil locomoteur, Aix Marseille Université - Assistance publique des Hôpitaux de Marseille, 270, boulevard Sainte-Marguerite, 13009 Marseille, France
| | - Sebastien Parratte
- Institut du Mouvement et de l'appareil locomoteur, Aix Marseille Université - Assistance publique des Hôpitaux de Marseille, 270, boulevard Sainte-Marguerite, 13009 Marseille, France; International Knee & Joint Centre, Hazza Bin Zayed Street, Intersection with Fatima Bint Mubarak Street Opposite Burjeel Hospital, 46705 Abu Dhabi, United Arab Emirates
| | - Matthieu Ollivier
- Institut du Mouvement et de l'appareil locomoteur, Aix Marseille Université - Assistance publique des Hôpitaux de Marseille, 270, boulevard Sainte-Marguerite, 13009 Marseille, France
| | - Xavier Flecher
- Institut du Mouvement et de l'appareil locomoteur, Aix Marseille Université - Assistance publique des Hôpitaux de Marseille, 270, boulevard Sainte-Marguerite, 13009 Marseille, France.
| |
Collapse
|
4
|
Zampogna B, Papalia GF, Ferrini A, Torre G, Vorini F, Diaz Balzani LA, Farsetti P, Papalia R. Dual-mobility total hip arthroplasty in patients younger than 55 years old: a systematic review. Arch Orthop Trauma Surg 2023; 143:6821-6828. [PMID: 37062001 DOI: 10.1007/s00402-023-04882-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Accepted: 04/09/2023] [Indexed: 04/17/2023]
Abstract
Total hip arthroplasty (THA) is regarded as one of the most successful and cost-effective orthopedic procedures. However, THA is a surgical procedure with potential intraoperative and postoperative risks. Dislocation is one of the common postoperative complications and remains one of the main indications for THA revision. The purpose of this systematic review was to evaluate the role and the outcomes of dual-mobility implant to prevent dislocation in patients younger than < 55 years in primary THA. In this systematic review, we included observational, prospective, and retrospective studies that evaluated the outcome and the complications of the dual-mobility cup in < 55-year-old patients. After applying exclusion criteria (femoral neck fractures or THA revision, case series, reviews, and meta-analyses), ten articles were included in the study. The overall number of participants in all the studies was 1530. The mean age of the participants was 50 years. The mean follow-up was 11.7 years. A total of 46 patients (2.7%) reported intraprosthetic dislocations, in which the polyethylene liner dissociates from the femoral head, while 4.8% of revision was due to aseptic loosening. The mean revision rate at twelve years was 11%. The mean value of Harris Hip Score increased from 50.9 pre-operatively to 91.6 after surgery. Dual mobility is a valid option for young patients with extended survivorship and low rates of instability and dislocation after primary THA.
Collapse
Affiliation(s)
- Biagio Zampogna
- Department of Orthopaedic and Trauma Surgery, Università Campus Bio-Medico Di Roma, Via Alvaro del Portillo, 21-00128, Rome, Italy
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200-00128, Rome, Italy
| | - Giuseppe Francesco Papalia
- Department of Orthopaedic and Trauma Surgery, Università Campus Bio-Medico Di Roma, Via Alvaro del Portillo, 21-00128, Rome, Italy.
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200-00128, Rome, Italy.
| | - Augusto Ferrini
- Department of Clinical Science and Translational Medicine, Section of Orthopaedics and Traumatology, University of Rome "Tor Vergata", Rome, Italy
| | - Guglielmo Torre
- Department of Orthopaedic and Trauma Surgery, Università Campus Bio-Medico Di Roma, Via Alvaro del Portillo, 21-00128, Rome, Italy
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200-00128, Rome, Italy
| | - Ferruccio Vorini
- Department of Orthopaedic and Trauma Surgery, Università Campus Bio-Medico Di Roma, Via Alvaro del Portillo, 21-00128, Rome, Italy
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200-00128, Rome, Italy
| | - Lorenzo Alirio Diaz Balzani
- Department of Orthopaedic and Trauma Surgery, Università Campus Bio-Medico Di Roma, Via Alvaro del Portillo, 21-00128, Rome, Italy
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200-00128, Rome, Italy
| | - Pasquale Farsetti
- Department of Clinical Science and Translational Medicine, Section of Orthopaedics and Traumatology, University of Rome "Tor Vergata", Rome, Italy
| | - Rocco Papalia
- Department of Orthopaedic and Trauma Surgery, Università Campus Bio-Medico Di Roma, Via Alvaro del Portillo, 21-00128, Rome, Italy
- Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200-00128, Rome, Italy
| |
Collapse
|
5
|
Rodríguez-Zamorano P, Otero Otero J, Pérez González A, Moro Rodríguez LE, Marco F. Primary total hip arthroplasty in patients with sequelae of poliomyelitis. Rev Esp Cir Ortop Traumatol (Engl Ed) 2023; 67:401-410. [PMID: 37011859 DOI: 10.1016/j.recot.2023.03.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 03/12/2023] [Accepted: 03/23/2023] [Indexed: 04/03/2023] Open
Abstract
INTRODUCTION Total hip arthroplasty (THA) in patients with residual poliomyelitis (RP) is a surgical challenge. Dysplastic morphology, osteoporosis and gluteal weakness hinder orientation, increase fracture risk and reduce implant stability. The aim of this study is to describe a series of patients with RP treated by THA. MATERIAL AND METHODS Retrospective descriptive study of patients with RP treated with THA between 1999 and 2021 in a tertiary hospital, with clinical and radiological follow-up and functional and complication evaluation until present or death, with a minimum of 12months. RESULTS Sixteen patients underwent surgery, with 13THA implanted in the paretic limb, 6 for fracture and 7 for osteoarthritis, while the remaining 3 were implanted in the contralateral limb. Four dual mobility cups were implanted as an antiluxation measure. At 1year postoperatively, 11 had complete range of motion with no increase in Trendelenburg cases. The Harris hip score (HHS) improved 32.1points, the visual analog scale (VAS) 5.25 points, and the Merlé-d'Augbiné-Poste scale 6 points. The length discrepancy correction was 13.77mm. Median follow-up was 3.5years (1-24). Two cases were revised for polyethylene wear and two for instability, with no infections, periprosthetic fractures, or cup or stem loosening. CONCLUSIONS THA in patients with RP allows improvement of the clinico-functional situation with an acceptable complication rate. The risk of dislocation could be minimized with dual mobility cups.
Collapse
Affiliation(s)
- P Rodríguez-Zamorano
- Departamento de Cirugía Ortopédica y Traumatología, Hospital Clínico San Carlos, Madrid, España.
| | - J Otero Otero
- Departamento de Cirugía Ortopédica y Traumatología, Hospital Clínico San Carlos, Madrid, España
| | - A Pérez González
- Departamento de Cirugía Ortopédica y Traumatología, Hospital Clínico San Carlos, Madrid, España
| | - L E Moro Rodríguez
- Departamento de Cirugía Ortopédica y Traumatología, Hospital Clínico San Carlos, Madrid, España
| | - F Marco
- Departamento de Cirugía Ortopédica y Traumatología, Hospital Clínico San Carlos, Madrid, España; Departamento de Cirugía, Universidad Complutense de Madrid, Madrid, España
| |
Collapse
|
6
|
Rodríguez-Zamorano P, Otero Otero J, Pérez González A, Moro Rodríguez LE, Marco F. [Translated article] Primary total hip arthroplasty in patients with sequelae of poliomyelitis. Rev Esp Cir Ortop Traumatol (Engl Ed) 2023; 67:T401-T410. [PMID: 37328055 DOI: 10.1016/j.recot.2023.06.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Accepted: 03/23/2023] [Indexed: 06/18/2023] Open
Abstract
INTRODUCTION Total hip arthroplasty (THA) in patients with residual poliomyelitis (RP) is a surgical challenge. Dysplastic morphology, osteoporosis and gluteal weakness hinder orientation, increase fracture risk and reduce implant stability. The aim of this study is to describe a series of patients with RP treated by THA. MATERIAL AND METHODS Retrospective descriptive study of patients with RP treated with THA between 1999 and 2021 in a tertiary hospital, with clinical and radiological follow-up and functional and complication evaluation until present or death, with a minimum of 12 months. RESULTS Sixteen patients underwent surgery, with 13 THA implanted in the paretic limb, 6 for fracture and 7 for osteoarthritis, while the remaining 3 were implanted in the contralateral limb. Four dual mobility cups were implanted as an antiluxation measure. At 1 year postoperatively, 11 had complete range of motion with no increase in Trendelenburg cases. The Harris hip score (HHS) improved 32.1 points, the visual analogue scale (VAS) 5.25 points, and the Merlé-d'Augbiné-Poste scale 6 points. The length discrepancy correction was 13.77mm. Median follow-up was 3.5 years (1-24). Two cases were revised for polyethylene wear and two for instability, with no infections, periprosthetic fractures, or cup or stem loosening. CONCLUSIONS THA in patients with RP allows improvement of the clinico-functional situation with an acceptable complication rate. The risk of dislocation could be minimised with dual mobility cups.
Collapse
Affiliation(s)
- P Rodríguez-Zamorano
- Departamento de Cirugía Ortopédica y Traumatología, Hospital Clínico San Carlos, Madrid, Spain.
| | - J Otero Otero
- Departamento de Cirugía Ortopédica y Traumatología, Hospital Clínico San Carlos, Madrid, Spain
| | - A Pérez González
- Departamento de Cirugía Ortopédica y Traumatología, Hospital Clínico San Carlos, Madrid, Spain
| | - L E Moro Rodríguez
- Departamento de Cirugía Ortopédica y Traumatología, Hospital Clínico San Carlos, Madrid, Spain
| | - F Marco
- Departamento de Cirugía Ortopédica y Traumatología, Hospital Clínico San Carlos, Madrid, Spain; Departamento de Cirugía, Universidad Complutense de Madrid, Madrid, Spain
| |
Collapse
|
7
|
Weintraub MT, DeBenedetti A, Nam D, Darrith B, Baker CM, Waren D, Schwarzkopf R, Courtney PM, Della Valle CJ. Dual-Mobility Versus Large Femoral Heads in Revision Total Hip Arthroplasty: Interim Analysis of A Randomized Controlled Trial. J Arthroplasty 2023:S0883-5403(23)00339-X. [PMID: 37019309 DOI: 10.1016/j.arth.2023.03.089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Revised: 03/21/2023] [Accepted: 03/24/2023] [Indexed: 04/07/2023] Open
Abstract
INTRODUCTION This multicenter randomized controlled trial evaluated if dual-mobility bearings (DM) lower the risk of dislocation compared to large femoral heads (≥36mm) for patients undergoing revision total hip arthroplasty (THA) via a posterior approach. METHODS A total of 146 Patients were randomized to a DM (n=76; 46 mm median effective head size, range 36 to 59 mm) or a large femoral head (n=70; twenty-five 36 mm heads [35.7%], forty-one 40 mm heads [58.6%], and four 44mm heads [5.7%]). There were 71 single-component revisions (48.6%), 39 both-component revisions (26.7%), 24 reimplantations of THA after 2-stage revision (16.4%), seven isolated head and liner exchanges (4.8%), four conversions of hemiarthroplasty (2.7%), and one revision of a hip resurfacing (0.7%). Power analysis determined that 161 patients were required in each group to lower the dislocation rate from 8.4 to 2.2% (power=0.8, alpha=0.05). RESULTS At a mean of 18.2 months (range, 1.4 to 48.2), there were three dislocations in the large femoral head group compared to two in the DM cohort (4.3 vs. 2.6%; P=0.67). One patient in the large head group and none in the DM group were successfully treated with closed reduction without subsequent revision. CONCLUSION Interim analysis of this randomized controlled trial found no difference in the risk of dislocation between DM and large femoral heads in revision THA, although the rate of dislocation was lower than anticipated and continued follow up is needed.
Collapse
Affiliation(s)
- Matthew T Weintraub
- Department of Orthopaedic Surgery, Rush University Medical Center, 1611 W Harrison Street, Chicago, IL 60612, USA
| | - Anne DeBenedetti
- Department of Orthopaedic Surgery, Rush University Medical Center, 1611 W Harrison Street, Chicago, IL 60612, USA
| | - Denis Nam
- Department of Orthopaedic Surgery, Rush University Medical Center, 1611 W Harrison Street, Chicago, IL 60612, USA
| | - Brian Darrith
- Department of Orthopaedic Surgery, Rush University Medical Center, 1611 W Harrison Street, Chicago, IL 60612, USA
| | - Colin M Baker
- Department of Orthopaedic Surgery, Rothman Institute, 925 Chestnut Street, Philadelphia, PA 19107, USA
| | - Daniel Waren
- Department of Orthopaedic Surgery, NYU Langone Orthopedic Hospital, 301 East 17(th) Street, New York, NY 10003, USA
| | - Ran Schwarzkopf
- Department of Orthopaedic Surgery, NYU Langone Orthopedic Hospital, 301 East 17(th) Street, New York, NY 10003, USA
| | - P Maxwell Courtney
- Department of Orthopaedic Surgery, Rothman Institute, 925 Chestnut Street, Philadelphia, PA 19107, USA
| | - Craig J Della Valle
- Department of Orthopaedic Surgery, Rush University Medical Center, 1611 W Harrison Street, Chicago, IL 60612, USA.
| |
Collapse
|
8
|
Manson TT, Adrados M, Gililland JM, Mahmood BM, Samuel LT, Moskal JT. The Role of Dual-Mobility Components in Total Hip Arthroplasty. J Bone Joint Surg Am 2023; 105:250-261. [PMID: 36473055 DOI: 10.2106/jbjs.22.00185] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
➤ Dual mobility (DM) refers to a now widely available option for total hip articulation. DM implants feature a small inner head, a hard bearing, that connects via a taper fit onto the femoral trunnion. This head freely rotates but is encased inside a larger, outer polyethylene head that articulates with a smooth acetabular component. ➤ DM acetabular components are available in the form of a monoblock shell or as a liner that is impacted into a modular shell, providing a metal articulation for the polyethylene outer head. ➤ DM is designed to increase hip stability by providing the arthroplasty construct with a higher jump distance, head-to-neck ratio, and range of motion prior to impingement. ➤ The use of DM in total hip arthroplasty continues to increase in the United States for both primary and revision arthroplasty. Surgeons should be aware of the potential benefits and pitfalls. ➤ Long-term data are lacking, especially for modular DM implants. Points of concern include a potential for accelerated polyethylene wear, intraprosthetic dislocation, and modular backside fretting corrosion.
Collapse
Affiliation(s)
- Theodore T Manson
- Department of Orthopaedic Surgery, University of Maryland, Baltimore, Maryland
| | - Murillo Adrados
- Department of Orthopaedic Surgery, Virginia Tech Carilion School of Medicine, Roanoke, Virginia.,Department of Orthopaedic Surgery, Carilion Clinic Institute of Orthopaedics and Neurosciences, Roanoke, Virginia
| | - Jeremy M Gililland
- Department of Orthopaedic Surgery, University of Utah, Salt Lake City, Utah
| | - Bilal M Mahmood
- Department of Orthopaedic Surgery, University of Utah, Salt Lake City, Utah
| | - Linsen T Samuel
- Department of Orthopaedic Surgery, Carilion Clinic Institute of Orthopaedics and Neurosciences, Roanoke, Virginia
| | - Joseph T Moskal
- Department of Orthopaedic Surgery, Virginia Tech Carilion School of Medicine, Roanoke, Virginia.,Department of Orthopaedic Surgery, Carilion Clinic Institute of Orthopaedics and Neurosciences, Roanoke, Virginia
| |
Collapse
|
9
|
Antoniadis A, Wegrzyn J. Direct Cementation of Dual Mobility Cups Into the Bony Acetabulum in Primary Total Hip Arthroplasty: Clinical and Radiographic Outcomes at a Minimum 5-Year Follow-Up. J Arthroplasty 2022; 38:1120-1125. [PMID: 36566998 DOI: 10.1016/j.arth.2022.12.031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Revised: 12/14/2022] [Accepted: 12/17/2022] [Indexed: 12/24/2022] Open
Abstract
BACKGROUND Cemented dual mobility cups (DMCs) are commonly used in combination with acetabular reinforcement devices. Indeed, according to literature, direct cementation of metal-backed acetabular components into the bony acetabulum remains controversial as this technique is potentially associated with increased rates of aseptic loosening. Therefore, this study aimed to evaluate the clinical and radiographic outcomes of DMC cemented into the bony acetabulum in primary total hip arthroplasty (THA). METHODS A total of 49 THA (48 patients, mean age 78 years [range, 51 to 91]) performed with direct cementation of a DMC into the bony acetabulum were prospectively included in our total joint registry and retrospectively reviewed. The clinical outcome was assessed using the Harris hip score (HHS). The radiographic outcome included measurement of component positioning and occurrence and progression of demarcation around the cemented DMC. Complications were reported with a particular attention to cemented fixation failure and aseptic loosening. RESULTS At a 7-year mean follow-up (range, 5 to 8), the pre-to postoperative HHS improved from 47 (range, 30 to 58) to 92 points (range, 80 to 98) (P < .01). Nonprogressive and focalized demarcations were observed in 7 THA (14%). Importantly, no progressive demarcation or DMC aseptic loosening was observed. CONCLUSION Direct cementation of DMC into the bony acetabulum ensured a stable fixation with no progressive demarcation or aseptic loosening at midterm follow-up. Therefore, this technique can be selectively considered in primary THA, especially in elderly or frail patients to avoid potential mechanical failure of press-fit fixation due to altered bone quality or additional morbidity related to the use of acetabular reinforcement devices.
Collapse
Affiliation(s)
- Alexander Antoniadis
- Department of Orthopaedic Surgery, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Julien Wegrzyn
- Department of Orthopaedic Surgery, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| |
Collapse
|
10
|
A Meta-Analysis of the Incidence and Temporal Trends of Postoperative Dislocation in Revision Total Hip Arthroplasty Utilizing Constrained Acetabular Components or Dual Mobility Implants. J Arthroplasty 2022; 38:957-969.e1. [PMID: 36481281 DOI: 10.1016/j.arth.2022.11.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 11/07/2022] [Accepted: 11/28/2022] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND The incidence of dislocation after revision total hip arthroplasty (rTHA) is reported to be up to 25% and remains a common source of failure. Constrained acetabular components and dual mobility implants are two implant classes being utilized to alleviate this burden in patients who have recurrent instability or major intraoperative instability. This meta-analysis evaluated the incidence and temporal trends of dislocation after implantation with constrained acetabular components and dual mobility implants in rTHA. METHODS Longitudinal studies reporting dislocation after the use of constrained acetabular components or dual mobility implants in rTHA were sought from Medline and Embase to October 2022. Secondary outcomes included re-revision surgery for dislocation and all causes. A total of 75 relevant citations were identified comprising 36 datasets of 3,784 constrained acetabular components and 47 datasets of 10,216 dual mobility implants. RESULTS For constrained acetabular components, the pooled incidence of dislocation was 9% (95% confidence interval: 7.2, 11.7) (range 0.0%-35.3%) over a weighted mean follow-up of 6 years, in contrast to 3% (95% confidence interval: 2.2, 4.4) (range 0.0%-21.4%) over 5 years for dual mobility implants. Re-revision rates for dislocation after using constrained acetabular components were around 9%, in contrast to 2% for dual mobility implants. Re-revision rates for all causes after using constrained acetabular components were around 19%, in contrast to 8% for dual mobility implants. CONCLUSION Dual mobility implants in the context of rTHA demonstrate lower incidences of dislocation (3% versus 9%), re-revision for dislocation (2% versus 9%), and rer-evision for any cause (8% versus 19%) in contrast to constrained acetabular components. This must be considered by surgeons when implanting such devices, often selected to treat instability.
Collapse
|
11
|
Ulgelmo M, Sandri A, Regis D, Casablanca E, Toso G, Valentini R, Magnan B. Late intraprosthetic dislocation of a monoblock dual-mobility cup cemented into a well-fixed cementless acetabular shell. A case report. ACTA BIO-MEDICA : ATENEI PARMENSIS 2022; 93:e2022206. [PMID: 36129744 PMCID: PMC10510970 DOI: 10.23750/abm.v93is1.12553] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 11/13/2021] [Accepted: 01/10/2022] [Indexed: 12/14/2022]
Abstract
Intraprosthetic dislocation (IPD) is a specific implant-related complication of dual mobility (DM) implants, which is defined as a dissociation of polyethylene (PE) liner from the femoral head. We report a unique case of late IPD of a monoblock DM cup cemented into a well-fixed cementless acetabular shell for recurrent dislocation of total hip arthroplasty (THA). A 77-year-old woman was admitted to our department for acute right hip pain, functional impairment and inability to bear weight without any trauma. Three years earlier, she underwent revision THA for recurrent dislocation with a monoblock DM cup cemented into a well-fixed cementless acetabular shell according to the "double-socket" technique. Three months after that revision the patient experienced an anterior THA dislocation, which was managed by closed reduction under sedation in the emergency room. No additional episodes of prosthesis instability occurred. Upon admission, radiographic evaluation showed right THA dislocation. X-rays performed after closed reduction revealed eccentric positioning of the head inside the cup, and a direct contact between the metal head and the cup was revealed by subsequent CT scan, confirming the suspicion of IPD. The patient underwent revision surgery, during which the PE liner was found lodged within the cup in a subluxated position, disassembled from the inner head. Both the acetabular cup and modular femoral stem proved well-fixed and impossible to remove, therefore they were retained. The explanted DM components were replaced with new ones of the same size and, thanks to the femoral neck's modular nature, it was substituted with a longer one, which resulted in improved stability against intraoperative stress maneuvers. The postoperative course was uncomplicated. At 1-year follow-up, the patient had a good functional recovery.
Collapse
Affiliation(s)
| | | | | | | | - Giovanna Toso
- Azienda ULSS n. 6 Euganea - Ospedale Civile di Cittadella.
| | | | | |
Collapse
|
12
|
Beckert M, Meneghini RM, Meding JB. Instability After Primary Total Hip Arthroplasty: Dual Mobility Versus Jumbo Femoral Heads. J Arthroplasty 2022; 37:S571-S576. [PMID: 35271976 DOI: 10.1016/j.arth.2022.02.113] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Revised: 02/17/2022] [Accepted: 02/28/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND The use of dual mobility (DM) articulations has grown substantially over the last decade to help minimize dislocation risk. The purpose of this study is to compare the results of DM articulations to jumbo femoral heads of equivalent sizes as they relate to postoperative dislocation. METHODS This is a retrospective cohort study of primary total hip arthroplasties (THAs) performed at a single institution between 2005 and 2018. DM articulations and large-diameter metal-on-metal femoral heads were included. Patients were followed with Harris Hip Scores and standard radiographs. Complications were prospectively recorded. Statistical analyses included chi-squared and Brown-Forsythe tests. RESULTS In total, 1,288 Magnum femoral head THAs and 365 Active Articulation DM THAs were included for analysis. The same monoblock cup was implanted via a posterior approach in all cases. Age, gender, body mass index, and diagnosis were similar between groups. Average follow-up in the DM group was 49 months, and 126 months in the jumbo head group. The average head sizes in the DM and jumbo head groups were 50 mm. There were no dislocations in the DM hips and only 2 (0.2%) in the jumbo femoral head group. Both groups had significant improvements in Harris Hip Score from their preoperative baseline. CONCLUSION Our study found similarly low dislocation rates in DM and jumbo femoral heads in primary THA. No evidence currently exists showing a benefit of the DM articulation beyond that of the large effective head size, and we recommend making every attempt at maximizing head size prior to using DM articulations.
Collapse
Affiliation(s)
- Mitchell Beckert
- The Department of Orthopaedic Surgery, Indiana University School of Medicine, Indianapolis, IN; The IU Hip and Knee Center, Fishers, IN
| | - R Michael Meneghini
- The Department of Orthopaedic Surgery, Indiana University School of Medicine, Indianapolis, IN; The IU Hip and Knee Center, Fishers, IN
| | - John B Meding
- The Center for Hip and Knee Surgery, St. Francis Hospital Mooresville, Mooresville, IN
| |
Collapse
|
13
|
Singh V, Thomas J, Arraut J, Oakley CT, Rozell JC, Davidovitch RI, Schwarzkopf R. Similar Outcomes Achieved Between Anterior and Posterior Approach Total Hip Arthroplasty Using Dual Mobility Implants. THE IOWA ORTHOPAEDIC JOURNAL 2022; 42:137-143. [PMID: 35821937 PMCID: PMC9210419] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
BACKGROUND Dual mobility (DM) bearings for total hip arthroplasty (THA) have been proposed to reduce the risk of instability in high-risk patients; however, their utility in primary THA remains relatively unexplored. No previous reports have described whether surgical approach influences outcomes associated with DM implant systems. This study aims to compare patient reported outcomes and post-operative groin pain between patients undergoing anterior approach versus posterior approach following primary THA with DM implants. METHODS We retrospectively reviewed all patients who underwent primary THA and received a DM implant between 2011-2021. Patients were stratified into two cohorts based on surgical approach (anterior vs. posterior approach). Primary outcomes included the presence of substantial postoperative groin pain as well as readmission and revision rates. Demographic differences were assessed using chi-square and independent sample t-tests. Outcomes were compared using multilinear and logistic regressions. RESULTS Of the 495 patients identified, 55 (11%) underwent THA via the anterior approach and 440 (89%) via the posterior approach. Surgical time (100.24 vs. 109.42 minutes, p=0.070), length of stay (2.19vs.2.67 days,p=0.072), discharge disposition (p=0.151), and significant postoperative groin pain (1.8%vs.0.7%,p=0.966) did not statistically differ between the cohorts. 90-day readmission (9.1%vs.7.7%,p=0.823) and revision rate (0.0%vs.3.0%,p=0.993) did not significantly differ as well. Specifically, readmission (p=0.993) and revision (p=0.998) for instability did not significantly differ between the cohorts. We found no statistical difference in HOOS, JR (p=0.425), VR-12 PCS (p=0.718), and VR-12 MCS (p=0.257) delta score improvement from preoperative to 1-year follow-up between the two groups. CONCLUSION Comparable outcomes following implantation of DM constructs may be achievable irrespective of the surgical approach employed. The incidence of iliopsoas injections for groin pain did not significantly differ between anterior and posterior approaches. Future investigation is needed to determine whether surgical approach influences long-term outcomes in patients receiving DM implants. Level of Evidence: III.
Collapse
Affiliation(s)
- Vivek Singh
- Department of Orthopedic Surgery, NYU Langone Health, New York, New York, USA
| | - Jeremiah Thomas
- Department of Orthopedic Surgery, NYU Langone Health, New York, New York, USA
| | - Jerry Arraut
- Department of Orthopedic Surgery, NYU Langone Health, New York, New York, USA
| | - Christian T. Oakley
- Department of Orthopedic Surgery, NYU Langone Health, New York, New York, USA
| | - Joshua C. Rozell
- Department of Orthopedic Surgery, NYU Langone Health, New York, New York, USA
| | - Roy I. Davidovitch
- Department of Orthopedic Surgery, NYU Langone Health, New York, New York, USA
| | - Ran Schwarzkopf
- Department of Orthopedic Surgery, NYU Langone Health, New York, New York, USA
| |
Collapse
|
14
|
Influence of dual-mobility acetabular implants on revision and survivorship of cup and Kerboull-type reinforcement ring constructs in aseptic acetabular loosening. Orthop Traumatol Surg Res 2022; 108:103071. [PMID: 34560312 DOI: 10.1016/j.otsr.2021.103071] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/12/2020] [Revised: 02/02/2021] [Accepted: 03/23/2021] [Indexed: 02/03/2023]
Abstract
INTRODUCTION Dual-mobility (DM) acetabular implants have been used in revision total hip arthroplasty (THA) to prevent postoperative instability, with excellent mid-term survivorship. However, few comparative studies assessed the long-term outcomes of DM implants used in Kerboull-type reinforcement ring constructs for acetabular revision. The present study aimed to compare long-term survivorship, dislocation rates and clinical outcome between DM acetabular implants and conventional single-bearing (SB) implants when cemented in a reinforcement ring. HYPOTHESIS Dual-mobility implants are associated with equivalent survivorship and lower dislocation rates than SB implants. MATERIAL AND METHODS A retrospective study included 60 revision THAs for aseptic loosening using a Kerboull-type reinforcement ring, and finally included 2 groups of 23 patients with either DM or SB cemented acetabular implants after matching for age, gender, BMI and preoperative Harris hip score. Mean follow-up was 10 years (range, 6-14 years). Acetabular implant survivorship, dislocation rate and radiographic failure incidence (>5mm migration, progressive radiolucency, graft non-integration, reinforcement ring breakage) were compared between the two groups. Clinical outcomes used the Harris hip score, the Postel-Merle d'Aubigné score and the Parker score. RESULTS Survivorship free of aseptic acetabular re-revision was 89% at 10 years, with no significant difference between DM and SB (91% and 86%, respectively; p=0.54). Single-bearing implants showed a hazard ratio for dislocation of 6.7 (95% CI, 1.5-29.6; p=0.01) compared to DM implants. There were no significant differences in radiologic failure (10-year survivorship 72% and 64%, respectively; p=0.88) or functional scores. DISCUSSION The present study confirmed the impact of dual-mobility implants in reducing long-term dislocation risk when used in Kerboull-type reinforcement ring constructs for acetabular aseptic revision, with no increased risk of re-revision compared to conventional single-bearing implants. LEVEL OF EVIDENCE III, comparative retrospective study.
Collapse
|
15
|
Rotini M, Farinelli L, Natalini L, De Rosa F, Politano R, Cianforlini M, Pacetti E, Procaccini R, Magrini Pasquinelli F, Gigante A. Is Dual Mobility Total Hip Arthroplasty Surgery More Aggressive than Hemiarthroplasty when Treating Femoral Neck Fracture in the Elderly? A Multicentric Retrospective Study on 302 Hips. Geriatr Orthop Surg Rehabil 2022; 13:21514593221081375. [PMID: 35237459 PMCID: PMC8883369 DOI: 10.1177/21514593221081375] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Revised: 01/29/2022] [Accepted: 02/01/2022] [Indexed: 11/17/2022] Open
Abstract
Introduction Bipolar hemiarthroplasty (BHA) and total hip arthroplasty (THA) are validated treatments for displaced femoral neck fractures (DFNFs). BHA seldomly needs conversion to THA, but the latter has higher dislocation rate in FNFs. Dual Mobility THA offers a reduced dislocation rate and eliminates the risk of conversion. This study looks for differences between BHA and DMTHA in terms of surgical time, blood loss and transfusion, dislocation rate, mortality, and thromboembolic events. Material and Methods All patients were ≥75yo. Recorded data included use of anticoagulant/antiplatelet drugs, ASA, operative time, intra-operative complications, pre/post-operative hemoglobin values, transfusions, hospitalization time, DVT/PE, glomerular filtration rate, Charlson Comorbidity Index (CCI), dislocation at 60 days, and mortality at 30 days and 6 months. A secondary analysis compared the subgroups in different age range (75–85 and ≥ 86yo). Results In the cohort of 302 DFNF (93 BHA and 209 DMTHA) differences in mean age, CCI, and ASA score were significant. Once divided by age, the subgroups resulted comparable in terms of age and CCI, with no significant difference. A significant difference in surgical times showed DMTHA being an average 12 minutes longer than BHA. Significant was the ΔHB in the DMTHA subgroup which resulted lower compared to the BHA one. Difference in mean number of post-operative transfusion were not statistically significant. Conclusions From our data, DMTHA did not lead to an increase in mortality, morbidity, bleeding, or dislocation rate when compared to BHA and could be considered as treatment of choice for DFNFs especially in healthy and active patients.
Collapse
Affiliation(s)
- Marco Rotini
- Department of Clinical and Molecular Science, School of Medicine, Università Politecnica delle Marche, Ancona, Italy
| | - Luca Farinelli
- Department of Clinical and Molecular Science, School of Medicine, Università Politecnica delle Marche, Ancona, Italy
| | - Leonardo Natalini
- Department of Clinical and Molecular Science, School of Medicine, Università Politecnica delle Marche, Ancona, Italy
| | - Federico De Rosa
- Department of Clinical and Molecular Science, School of Medicine, Università Politecnica delle Marche, Ancona, Italy
| | - Rocco Politano
- Department of Orthopaedics and Traumatology, "Carlo Urbani" Hospital, Jesi, Italy
| | - Marco Cianforlini
- Department of Orthopaedics and Traumatology, "Carlo Urbani" Hospital, Jesi, Italy
| | - Emanuele Pacetti
- Department of Orthopaedics and Traumatology, "Carlo Urbani" Hospital, Jesi, Italy
| | - Roberto Procaccini
- Clinic of Adult and Paediatric Orthopaedic, "Umberto I" Hospital (Ospedali Riuniti di Ancona), Ancona, Italy
| | | | - Antonio Gigante
- Department of Clinical and Molecular Science, School of Medicine, Università Politecnica delle Marche, Ancona, Italy
| |
Collapse
|
16
|
Outcomes of revision total hip arthroplasty using the modular dual mobility acetabular system to treat recurrent dislocation. INTERNATIONAL ORTHOPAEDICS 2022; 46:789-795. [DOI: 10.1007/s00264-021-05280-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Accepted: 12/01/2021] [Indexed: 10/19/2022]
|
17
|
Monobloc Dual Mobility With a Minimum 5-Year Follow-Up: A Safe and Effective Solution in Primary Total Hip Arthroplasty. J Arthroplasty 2022; 37:83-88. [PMID: 34593287 DOI: 10.1016/j.arth.2021.09.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2021] [Revised: 08/29/2021] [Accepted: 09/07/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Instability constitutes over 20% of revisions after total hip arthroplasty (THA). Dual mobility (DM) designs were introduced as a solution to this problem. However, the few publications that have reported promising results for monobloc DM constructs have been limited by sample size or length of follow-up. The purpose of this study is to evaluate mid-term outcomes (minimum 5-year follow-up) of a single-surgeon series utilizing a monobloc DM acetabular component in patients with high risk for dislocation. METHODS This is a single-surgeon consecutive series of 207 primary THAs implanted with a monobloc DM component in patients who were considered at high risk for dislocation. Patient demographics and case-specific data were collected retrospectively. All patients had a minimum of 5-year follow-up. The Mann-Whitney U test was used to assess continuous variables, whereas categorical variables were analyzed using the chi-square test. Survival probability was calculated using the Kaplan-Meier method. RESULTS Radiographic analysis did not reveal acetabular radiolucency in any patients, and there were no revisions for aseptic loosening. In addition, there were no dislocations. Seven of 205 patients (3.4%) were revised, 5 on the femoral side due to periprosthetic fracture and the remaining two for infection. Survivorship of the acetabular component from revision was 99%. The mean Veteran RAND (VR-12) physical score improved from 7 (standard deviation [SD]: 13.7) preoperatively to 9.5 (SD: 17.6) at the final follow-up. Similarly, the hip disability osteoarthritis score improved from 8 (SD: 17.9) preoperatively to 21.2 (SD: 37). CONCLUSION Monobloc DM components reliably prevent dislocation after primary THA in high-risk patients. At mid-term follow-up, this DM monobloc component demonstrates excellent implant survivorship, radiographic fixation, and improved functional outcomes.
Collapse
|
18
|
Malhotra R, Gautam D, Gupta S, Eachempati KK. An algorithmic approach to total hip arthroplasty in patient with post-polio paralysis and fixed pelvic obliquity. Bone Jt Open 2021; 2:696-704. [PMID: 34465165 PMCID: PMC8479847 DOI: 10.1302/2633-1462.29.bjo-2021-0084.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Aims Total hip arthroplasty (THA) in patients with post-polio residual paralysis (PPRP) is challenging. Despite relief in pain after THA, pre-existing muscle imbalance and altered gait may cause persistence of difficulty in walking. The associated soft tissue contractures not only imbalances the pelvis, but also poses the risk of dislocation, accelerated polyethylene liner wear, and early loosening. Methods In all, ten hips in ten patients with PPRP with fixed pelvic obliquity who underwent THA as per an algorithmic approach in two centres from January 2014 to March 2018 were followed-up for a minimum of two years (2 to 6). All patients required one or more additional soft tissue procedures in a pre-determined sequence to correct the pelvic obliquity. All were invited for the latest clinical and radiological assessment. Results The mean Harris Hip Score at the latest follow-up was 79.2 (68 to 90). There was significant improvement in the coronal pelvic obliquity from 16.6o (SD 7.9o) to 1.8o (SD 2.4o; p < 0.001). Radiographs of all ten hips showed stable prostheses with no signs of loosening or migration, regardless of whether paralytic or non-paralytic hip was replaced. No complications, including dislocation or infection related to the surgery, were observed in any patient. The subtrochanteric shortening osteotomy done in two patients had united by nine months. Conclusion Simultaneous correction of soft tissue contractures is necessary for obtaining a stable hip with balanced pelvis while treating hip arthritis by THA in patients with PPRP and fixed pelvic obliquity. Cite this article: Bone Jt Open 2021;2(9):696–704.
Collapse
Affiliation(s)
- Rajesh Malhotra
- Orthopedics department, All India Institute of Medical Sciences, New Delhi, India
| | - Deepak Gautam
- Orthopedics department, All India Institute of Medical Sciences, New Delhi, India
| | - Saurabh Gupta
- Orthopedics department, All India Institute of Medical Sciences, New Delhi, India
| | | |
Collapse
|
19
|
Yang S, Xie F, Cui W, Zhang Y, Jin Z. A review of the clinical and engineering performance of dual-mobility cups for total hip arthroplasty. Am J Transl Res 2021; 13:9383-9394. [PMID: 34540057 PMCID: PMC8430055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Accepted: 02/20/2021] [Indexed: 06/13/2023]
Abstract
Charnley's low-friction principle of total hip arthroplasty (THA) is recognized as the gold standard. However, complications may arise, and one of the major reasons for revising THA is dislocation. Under such a background, Pr. Gilles Bousquet invented dual-mobility cups (DMC) in the 1970s to fight against hip instability. Despite the excellent clinical results of DMC compared with conventional implants, the clinical application of DMC is limited by concerns about the dual articulations, leading to rapid wear and the subsequent osteolysis and the wear on the retaining rim of the liner due to its contact with the femoral neck causing intraprosthetic dislocation (IPD). As a result, the original design of DMC has been upgraded by using highly cross-linked polyethylene, refining the geometry of the femoral neck, etc. After the improvement, the wear rate of the contemporary DMC liners has been largely reduced compared with the first generation DMC, and the IPD incidence rate has been controlled. However, with the increasing fretting corrosion damage found at the taper-trunnion interfaces in conventional implants, the contemporary DMC may face a similar problem. This is because the additional articulation and the larger head design of DMC gain the risk of articulation wear and taper-trunnion interface corrosion. Since there are still many potential DMC engineering issues that have not been extensively researched, future studies focusing on the wear and corrosion aspects are required. The purpose of this review article is to summarize both the clinical and engineering issues for DMC with possible directions for future research.
Collapse
Affiliation(s)
- Shu Yang
- School of Mechanical Engineering, Southwest Jiaotong UniversityChengdu 610031, China
- Beijing Chunlizhengda Medical Instruments Co., Ltd.Beijing 101100, China
| | - Fengbao Xie
- Beijing Chunlizhengda Medical Instruments Co., Ltd.Beijing 101100, China
| | - Wen Cui
- School of Mechanical Engineering, Southwest Jiaotong UniversityChengdu 610031, China
| | - Yali Zhang
- School of Mechanical Engineering, Southwest Jiaotong UniversityChengdu 610031, China
| | - Zhongmin Jin
- School of Mechanical Engineering, Southwest Jiaotong UniversityChengdu 610031, China
| |
Collapse
|
20
|
Grace TR, Goh GS, Lee GC, Kamath AF, Kurtz SM, Courtney PM. Dual Mobility Reduces Dislocations-Why I Use It in All Revisions. J Arthroplasty 2021; 36:S63-S69. [PMID: 33526395 DOI: 10.1016/j.arth.2021.01.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/03/2021] [Accepted: 01/05/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Instability remains the most common complication after revision total hip arthroplasty (THA) and presents a unique treatment dilemma for the orthopedic surgeon. Dual mobility (DM) bearing articulations have been used in France since the 1970s, but have only become more widely adopted in the United States over the last decade. The purpose of this symposium was to discuss the role for DM bearings in revision THA. METHODS We reviewed the existing literature on outcomes after DM bearing articulations in revision THA. We also report several case examples of the use of DM in difficult revision THA cases, including acetabular bone loss, failed constrained liner, and adverse local tissue reaction. Finally, we briefly discuss the limitations associated with the use of DM. RESULTS Several large retrospective series demonstrate that DM bearings reduce the incidence of dislocation after revision THA when compared with conventional single bearing THA. Specific complications related to DM bearings including polyethylene wear, loosening, intraprosthetic dislocation, and corrosion remain a concern, but appear to have drastically improved over time with modern implant designs. CONCLUSION Contemporary DM designs have been established as an effective bearing option to reduce instability in revision THA, although concerns do exist. High-quality prospective studies are necessary to further define the role this bearing option has in the coming years.
Collapse
Affiliation(s)
- Trevor R Grace
- Rothman Orthopaedic Institute at Thomas Jefferson University Hospital, Philadelphia, PA
| | - Graham S Goh
- Rothman Orthopaedic Institute at Thomas Jefferson University Hospital, Philadelphia, PA
| | - Gwo-Chin Lee
- Penn Presbyterian Medical Center, University of Pennsylvania School of Medicine, Department of Orthopaedic Surgery, Philadelphia, PA
| | - Atul F Kamath
- Cleveland Clinic, Department of Orthopaedic Surgery, Cleveland, OH
| | - Steven M Kurtz
- Exponent Inc and Drexel University School of Biomedical Engineering, Science, and Health Systems, Philadelphia, PA
| | - P Maxwell Courtney
- Rothman Orthopaedic Institute at Thomas Jefferson University Hospital, Philadelphia, PA
| |
Collapse
|
21
|
Castiello E, Moghnie A, Tigani D, Affatato S. Dual mobility cup in hip arthroplasty: an in-depth analysis of joint registries. Artif Organs 2021; 46:804-812. [PMID: 34153137 DOI: 10.1111/aor.14015] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Revised: 04/23/2021] [Accepted: 06/07/2021] [Indexed: 11/28/2022]
Abstract
Although total hip arthroplasty (THA) has shown successful results, instability remains a major complication. In recent years, dual mobility cups (DMC) have gained interest among clinicians thanks to its low rate of dislocation and good clinical results. The main aim of this work was to describe the accuracy of data on DMC from national and regional joint registries (JRs) and the available worldwide literature. We identified topics on DMC among JRs to propose a new harmonized and standardized section for DMC with the aim to understand its surveillance over the time. We extracted survival and implant data for a separate analysis. After performing a critical exclusion process, nine joint registries were considered eligible and included for final synthesis; these were the results from the available worldwide data from Joints Registries (JRs). In our study, eight analysed JRs reported a slight increase in DMC use in the last decade. In all the JRs evaluated and the available articles, dislocation remains one of the main reasons for revision and re-revision in hip arthroplasties. DMC is considered a valid construct increasingly used worldwide in primary and revision THA with the primary aim of reducing dislocation rates. Annual reports from JRs collect heterogeneous and low-quality information about outcomes and surveillance of DMC, creating a burden for clinicians to extract comparable data from different JR. Longer follow-up and a systematic registering of DMCs with international registry harmonization are needed to monitor DMC outcomes.
Collapse
Affiliation(s)
| | | | - Domenico Tigani
- Department of Orthopaedic Surgery, Ospedale Maggiore, Bologna, Italy
| | - Saverio Affatato
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| |
Collapse
|
22
|
Dual-Mobility Articulations in Femoral Neck Fractures: A Systematic Review of the Literature and Meta-analysis of the Outcomes. J Am Acad Orthop Surg 2021; 29:e618-e627. [PMID: 32925381 DOI: 10.5435/jaaos-d-20-00407] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Accepted: 05/24/2020] [Indexed: 02/01/2023] Open
Abstract
INTRODUCTION Femoral neck fractures have been traditionally managed with hemiarthroplasty (HA) or conventional total hip arthroplasty (CTHA). There has been recent interest in using dual-mobility components (DMC) in total hip arthroplasty for patients with femoral neck fractures to provide increased stability and decrease the need for future revision. METHODS We conducted a systematic review of the literature reporting on the use of DMC in the management of femoral neck fractures in geriatric patients. We included studies in which DMC were used alone and studies that included a comparison to total hip arthroplasty or HA. The outcomes of interest were postoperative dislocation, revision, and revision surgery rates. Two separate subgroup analyses were conducted. For the comparative studies, we analyzed the differences in outcomes using a random-effects model of relative risks. For the noncomparative studies, we estimated the cumulative incidence of the different outcomes. RESULTS Eighteen studies met the inclusion criteria and were included in our analysis. Eleven noncomparative studies showed a cumulative incidence of dislocation to be 1.2% (95% confidence interval = 0.3% to 2.7%) when DMC were used alone. Subgroup analyses of the seven comparative studies yielded a relative risk of dislocation using DMC was 59% less than HA and 83% less than CTHA. DMC also compared favorably in terms of revision surgery and revision rates to HA. There was insufficient quality evidence to comment on revision surgery and revision rates when compared with CTHA in comparative studies, but among the noncomparative studies, there was a low rate of revision and revision surgery. CONCLUSIONS Our study revealed overall lower risk of dislocation using DMC compared with both CTHA and HA. There were also lower revision and revision surgery rates when DMC were used compared with HA. Further studies are required to elucidate cost-effectiveness and long-term outcomes of DMC in these scenarios. LEVEL OF EVIDENCE Level III-meta-analysis.
Collapse
|
23
|
Pai FY, Ma HH, Chou TFA, Huang TW, Huang KC, Tsai SW, Chen CF, Chen WM. Risk factors and modes of failure in the modern dual mobility implant. A systematic review and meta-analysis. BMC Musculoskelet Disord 2021; 22:541. [PMID: 34126990 PMCID: PMC8204435 DOI: 10.1186/s12891-021-04404-4] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Accepted: 05/24/2021] [Indexed: 02/08/2023] Open
Abstract
Background The aims of this meta-analysis were to: (1) validate the outcome of modern dual mobility (DM) designs in patients who had undergone primary and revision total hip arthroplasty (THA) procedures and (2) to identify factors that affect the outcome. Methods We searched for studies that assessed the outcome of modern DM-THA in primary and revision procedures that were conducted between January, 2000 to August, 2020 on PubMed, MEDLINE, Cochrane Reviews and Embase. The pooled incidence of the most common failure modes and patient reported outcomes were evaluated in patients who have received: (1) primary THA, (2) revision THA for all causes or (3) for recurrent dislocation. A meta-regression analysis was performed for each parameter to determine the association with the outcome. The study design of each study was assessed for potential bias and flaws by using the quality assessment tool for case series studies. Results A total of 119 studies (N= 30016 DM-THAs) were included for analysis. The mean follow-up duration was 47.3 months. The overall implant failure rate was 4.2% (primary: 2.3%, revision for all causes: 5.5%, recurrent dislocation: 6.0%). The most common failure modes were aseptic loosening (primary: 0.9%, revision for all causes: 2.2%, recurrent dislocation: 2.4%), septic loosening (primary:0.8%, revision for all causes: 2.3%, recurrent dislocation: 2.5%), extra-articular dislocation (primary:0.6%, revision for all causes:1.3%, recurrent dislocation:2.5%), intra-prosthetic dislocation (primary:0.8%, revision for all causes:1.0%, recurrent dislocation:1.6%) and periprosthetic fracture (primary:0.9%, revision for all causes:0.9%, recurrent dislocation:1.3%). The multi-regression analysis identified younger age (β=-0.04, 95% CI -0.07 – -0.02) and female patients (β=3.34, 95% CI 0.91–5.78) were correlated with higher implant failure rate. Age, gender, posterolateral approach and body mass index (BMI) were not risk factors for extra-articular or intra-prosthetic dislocation in this cohort. The overall Harris hip score and Merle d’Aubigné score were 84.87 and 16.36, respectively. Level of evidence of this meta-analysis was IV. Conclusion Modern dual-mobility designs provide satisfactory mid-term implant survival and clinical performance. Younger age and female patients might impact the outcome after DM-THA. Future research directions should focus on, (1) long-term outcome of modern dual-mobility design, including specific concerns such as intra-prosthetic dislocation and elevated metal ion, and (2) cost-effectiveness analysis of dual-mobility implant as an alternative to conventional THA for patients who are at high risk of dislocation. Supplementary Information The online version contains supplementary material available at 10.1186/s12891-021-04404-4.
Collapse
Affiliation(s)
- Fu-Yuan Pai
- Department of Orthopaedics and Traumatology, Taipei Veterans General Hospital, No. 201, Sec 2, Shi-Pai Road, Taipei 112, Taiwan.,Department of Orthopaedics, School of Medicine, National Yang-Ming Chiao-Tung University, Taipei, Taiwan
| | - Hsuan-Hsiao Ma
- Department of Orthopaedics and Traumatology, Taipei Veterans General Hospital, No. 201, Sec 2, Shi-Pai Road, Taipei 112, Taiwan.,Department of Orthopaedics, School of Medicine, National Yang-Ming Chiao-Tung University, Taipei, Taiwan
| | - Te-Feng Arthur Chou
- Department of Orthopaedics and Traumatology, Taipei Veterans General Hospital, No. 201, Sec 2, Shi-Pai Road, Taipei 112, Taiwan.,Department of Orthopaedics, School of Medicine, National Yang-Ming Chiao-Tung University, Taipei, Taiwan
| | - Tsan-Wen Huang
- Chang Gung University College of Medicine, Taoyuan, Taiwan.,Department of Orthopaedic Surgery, Chang-Gung Memorial Hospital, Chiayi, Taiwan
| | - Kuo-Chin Huang
- Chang Gung University College of Medicine, Taoyuan, Taiwan.,Department of Orthopaedic Surgery, Chang-Gung Memorial Hospital, Chiayi, Taiwan
| | - Shang-Wen Tsai
- Department of Orthopaedics and Traumatology, Taipei Veterans General Hospital, No. 201, Sec 2, Shi-Pai Road, Taipei 112, Taiwan.,Department of Orthopaedics, School of Medicine, National Yang-Ming Chiao-Tung University, Taipei, Taiwan
| | - Cheng-Fong Chen
- Department of Orthopaedics and Traumatology, Taipei Veterans General Hospital, No. 201, Sec 2, Shi-Pai Road, Taipei 112, Taiwan. .,Department of Orthopaedics, School of Medicine, National Yang-Ming Chiao-Tung University, Taipei, Taiwan.
| | - Wei-Ming Chen
- Department of Orthopaedics and Traumatology, Taipei Veterans General Hospital, No. 201, Sec 2, Shi-Pai Road, Taipei 112, Taiwan.,Department of Orthopaedics, School of Medicine, National Yang-Ming Chiao-Tung University, Taipei, Taiwan
| |
Collapse
|
24
|
Giacomo P, Giulia B, Valerio P, Vincenzo S, Pierluigi A. Dual mobility for total hip arthroplasty revision surgery: A systematic review and metanalysis. SICOT J 2021; 7:18. [PMID: 33749588 PMCID: PMC7984151 DOI: 10.1051/sicotj/2021015] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/10/2020] [Accepted: 02/27/2021] [Indexed: 12/14/2022] Open
Abstract
INTRODUCTION Revision THA (R-THA) is thought to have a higher complication rate if compared to primary THA. Dual Mobility (DM) implants have been designed aiming for achieving greater stability, with good clinical results. However, scarce material can be found about the real improvements provided by this type of implant compared to traditional implant in Revisions of Total Hip Arthroplasties. METHODS A systematic review and meta-analysis of comparative studies were performed in December 2019. This was in accordance with the guidelines of Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA). Our primary outcome measure was overall survivorship and dislocation rate, either treated with a conservative method or requiring surgery. RESULTS Regarding the overall implant survival, we found a slight significant risk ratio, with a statistically meaningful difference between the two groups in questions in favour of the DM implant. A statistically significant difference in favour of the DM group turned out considering only the Dislocation rate Risk ratio and the aseptic loosening risk as well. No statistical difference was found between the two groups about the risk ratio of infection. DISCUSSION A steady increase of evidence is demonstrating the efficacy of using a DM cup system in THA revisions with low dislocation rates, but currently there is no study in the literature that demonstrates with statistically significant evidence. The main finding of the present study is that implant's Survivor and prevention of dislocation at medium follow-up showed better results with a DM if compared to a fixed-bearing cup, for Revision THA.
Collapse
Affiliation(s)
- Placella Giacomo
- Hospital San Raffaele - Orthopaedic Department, Milan 20132, Italy
| | | | - Pace Valerio
- Università degli Studi di Perugia, Perugia 06123, Italy
| | | | | |
Collapse
|
25
|
Unter Ecker N, Kocaoğlu H, Zahar A, Haasper C, Gehrke T, Citak M. What Is the Dislocation and Revision Rate of Dual-mobility Cups Used in Complex Revision THAs? Clin Orthop Relat Res 2021; 479:280-285. [PMID: 32898046 PMCID: PMC7899605 DOI: 10.1097/corr.0000000000001467] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2020] [Accepted: 08/03/2020] [Indexed: 01/31/2023]
Abstract
BACKGROUND Dual-mobility cups have been shown to reduce the dislocation risk after THA. Although dual-mobility cups can be a useful strategy to mitigate against recurrent dislocation after revision surgery, few clinical studies have focused on the results of complex revision THAs with extensive bone and soft-tissue loss or in patients who have undergone more than one previous surgical procedure. QUESTIONS/PURPOSES (1) What is the survival free from revision for dislocation of dual-mobility cups used in complex revision THAs? (2) What is the survival free from any dislocation? METHODS Between January 1, 2009 and December 31, 2013, 327 patients underwent a complex revision THA that included an acetabular revision, defined as preexisting massive bone loss in the acetabulum (at least Paprosky Type 2B) and/or proximal femur (at least Paprosky Type 3), substantial gluteal soft-tissue involvement, at least two previous surgical procedures or a one-stage septic revision, or history of dislocation. All 327 complex revision patients received a dual-mobility cup. Of those, 34% (111) were lost to follow-up before 5 years and were not known to have reached a study endpoint (revision for dislocation, and any dislocation) before then, leaving 216 patients for analysis. For patients with bilateral hip surgeries only the first operated hip was included for analysis. The median (range) follow-up duration was 69 months (60 to 110). The primary endpoint was dislocation or re-revision for dislocation. Fifty-six percent (120 of 216) of the patients were women and 44% (96 of 216) were men. The mean age of the patients was 69 ± 9 years. The patients underwent a median of four surgical procedures (1 to 4) before the index procedure (the revision evaluated in this study). A survival analysis was performed using the Kaplan-Meier method; any dislocation or revision for dislocation was determined as the endpoint. RESULTS The dislocation-free survival rates were 96% (95% confidence interval 92 to 98) at 5 years and 82% (95% CI 72 to 89) at 9 years. The overall dislocation rate was 11% (24 of 216 patients) at the final follow-up interval. Survival free of revision for dislocation was 99% (95% CI 96 to 100) at 5 years and 85% (95% CI 75 to 92) at 9 years. CONCLUSIONS Dual-mobility cups used in complex revision THA in this series had a higher rate of dislocation and revision than expected, based on earlier studies of dislocations of these components. Although we believe dual-mobility cups are still the first choice of implant if the patient has instability, these cups should be used cautiously if severe bone loss or soft-tissue involvement is present. LEVEL OF EVIDENCE Level III, therapeutic study.
Collapse
Affiliation(s)
- Niklas Unter Ecker
- N. U. Ecker, H. Kocaoğlu, C. Haasper, T. Gehrke, M. Citak, Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
- H. Kocaoğlu, Department of Orthopedics and Traumatology, Ankara University Faculty of Medicine, Ankara, Turkey
- A. Zahar, Department of Orthopaedic Surgery, Helios Klinik Berlin- Zehlendorf, Berlin, Germany
| | - Hakan Kocaoğlu
- N. U. Ecker, H. Kocaoğlu, C. Haasper, T. Gehrke, M. Citak, Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
- H. Kocaoğlu, Department of Orthopedics and Traumatology, Ankara University Faculty of Medicine, Ankara, Turkey
- A. Zahar, Department of Orthopaedic Surgery, Helios Klinik Berlin- Zehlendorf, Berlin, Germany
| | - Akos Zahar
- N. U. Ecker, H. Kocaoğlu, C. Haasper, T. Gehrke, M. Citak, Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
- H. Kocaoğlu, Department of Orthopedics and Traumatology, Ankara University Faculty of Medicine, Ankara, Turkey
- A. Zahar, Department of Orthopaedic Surgery, Helios Klinik Berlin- Zehlendorf, Berlin, Germany
| | - Carl Haasper
- N. U. Ecker, H. Kocaoğlu, C. Haasper, T. Gehrke, M. Citak, Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
- H. Kocaoğlu, Department of Orthopedics and Traumatology, Ankara University Faculty of Medicine, Ankara, Turkey
- A. Zahar, Department of Orthopaedic Surgery, Helios Klinik Berlin- Zehlendorf, Berlin, Germany
| | - Thorsten Gehrke
- N. U. Ecker, H. Kocaoğlu, C. Haasper, T. Gehrke, M. Citak, Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
- H. Kocaoğlu, Department of Orthopedics and Traumatology, Ankara University Faculty of Medicine, Ankara, Turkey
- A. Zahar, Department of Orthopaedic Surgery, Helios Klinik Berlin- Zehlendorf, Berlin, Germany
| | - Mustafa Citak
- N. U. Ecker, H. Kocaoğlu, C. Haasper, T. Gehrke, M. Citak, Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
- H. Kocaoğlu, Department of Orthopedics and Traumatology, Ankara University Faculty of Medicine, Ankara, Turkey
- A. Zahar, Department of Orthopaedic Surgery, Helios Klinik Berlin- Zehlendorf, Berlin, Germany
| |
Collapse
|
26
|
Thirty-Day Readmissions After Aseptic Revision Total Hip Arthroplasty: Rates, Predictors, and Reasons Vary by Surgical Indication. J Arthroplasty 2020; 35:3673-3678. [PMID: 32684401 DOI: 10.1016/j.arth.2020.06.069] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Revised: 06/01/2020] [Accepted: 06/23/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Revision total hip arthroplasty (rTHA) is performed for different surgical indications. With increasing attention being focused to minimize readmission risk, the National Surgical Quality Improvement Program (NSQIP) was used to assess 30-day readmissions after rTHA for 3 aseptic indications. METHODS Patients undergoing rTHA were identified in the 2013-2017 NSQIP and classified as being performed for osteolysis/aseptic loosening, recurrent dislocation, or periprosthetic fracture. Rates and predictors of 30-day readmission were determined by indication. Reasons for readmission were also assessed as being either related or unrelated to the surgical site. RESULTS Of 6104 patients meeting inclusion criteria, osteolysis/aseptic loosening represented 46% of the revisions (readmission rate: 6.2%), recurrent dislocation represented 33.2% (readmission rate: 10.9%), and periprosthetic fractures represented 20.9% (readmission rate: 9.3%). These readmission rates represented statistically significant variation across the 3 indications (P < .0001). On multivariate analysis, demographic, procedural, and postoperative predictors of readmission varied by indication. The osteolysis/aseptic loosening and periprosthetic fracture cohorts had surgical site-related readmissions in 43.9% and 42.4% of readmitted cases, respectively. On the contrary, readmissions after rTHA performed for recurrent dislocation were mostly surgical site-related (63.3%) and driven primarily by a postoperative dislocation. Further multivariate analysis showed that the rTHA indication of recurrent dislocation itself was the strongest predictor (odds ratio, 3.34; P < .0001) of a postoperative dislocation leading to a 30-day readmission. CONCLUSION Thirty-day readmissions varied from 6.2% to 10.9% based on surgical indication for aseptic rTHA. Reasons for readmission also differed across the 3 cohorts. These findings may aid postoperative care pathways and protocol optimization.
Collapse
|
27
|
Van Eecke E, Vanbiervliet J, Dauwe J, Mulier M. Comparison of Constrained Acetabular Components and Dual Mobility Cups in Revision Total Hip Arthroplasty: A Literature Review. Hip Pelvis 2020; 32:59-69. [PMID: 32566536 PMCID: PMC7295616 DOI: 10.5371/hp.2020.32.2.59] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/06/2019] [Revised: 10/10/2019] [Accepted: 10/23/2019] [Indexed: 12/26/2022] Open
Abstract
Recurrent instability remains a common cause of failure after revision total hip arthroplasty (THA). Dual mobility (DM) cups and designs with constrained acetabular liners (CAL) have both been developed to help overcome this challenge. The aim of this report is to compare safety and efficacy outcomes of both designs based on the literature. A comprehensive literature review including published evidence on the results of DM and CAL in revision THA was performed and summarized. Available literature focusing on overall survival, dislocation, loosening, intra-prosthetic dislocation (IPD), and functional outcomes were analysed. Forty-six reports including an evaluation of 5,617 total hips were evaluated were included in the review. The included studies were divided into two distinct groups based on implantation approach: i) CAL (n=15) and ii) DM (n=31). The DM group had higher overall survival rates (94.7% vs. 81.0%), lower dislocation rates (2.6% vs. 11.0%), and lower acetabular loosening rates (1.0% vs. 2.0%) compared to the CAL group. IPDs were reported in 6 studies (mean rate, 0.6%). No differences in functional outcomes were identified due to incomplete reports. Our observations reveal that designs with CAL have poorer outcomes as compared to DM cups in revision THA. Currently, the use of DM seems more appropriate since they offer lower rates of dislocations, loosening and re-revisions in the short- and mid-term. Concerns regarding the potential of increased wear in a younger, high-demand population require additional data and evaluation by long-term studies for the DM design.
Collapse
Affiliation(s)
- Eduard Van Eecke
- Department of Orthopedic Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Jens Vanbiervliet
- Department of Orthopedic Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Jan Dauwe
- Department of Orthopedic Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Michiel Mulier
- Department of Orthopedic Surgery, University Hospitals Leuven, Leuven, Belgium
| |
Collapse
|
28
|
Iatrogenic intraprosthetic dislocation after closed reduction of dual mobility total hip arthroplasty: Report of two cases. Int J Surg Case Rep 2020; 71:225-229. [PMID: 32480330 PMCID: PMC7262377 DOI: 10.1016/j.ijscr.2020.04.085] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2020] [Revised: 04/24/2020] [Accepted: 04/24/2020] [Indexed: 11/21/2022] Open
Abstract
INTRODUCTION Among hip arthroplasty, dual mobility aims to improve ROM and reduce dislocation rates, however this particular implant can fail in specific ways. Iatrogenic intraprosthetic dislocation (IPD) is a rare occurrence that can happen during closed reduction of a dislocated dual mobility total hip arthroplasty. PRESENTATION OF CASE #1 - A 34-year-old male who came to our attention with an undiagnosed IPD. He had experienced a classic dislocation 6 days earlier, which was treated with closed reduction. CT-scan confirmed decoupling of the metal head and PE liner. #2 - An 89-year-old male came to our attention for THA dislocation. During closed reduction manouvers he suffered IPD of the implant. Both patients were treated with revision surgery. DISCUSSION Despite being already reported in literature, IPD are still not well known to practitioners and sometimes overlooked even by orthopaedic specialists. Given the good results and diffusion of this kind of implant, iatrogenic IPD in the contest of a classic dislocation might become more frequent in the clinical practice. CONCLUSION When performing reduction maneuvers for a dislocated dual mobility total hip arthroplasty, X-rays must be carefully inspected for signs of IPD which, if undiagnosed, can lead to major implant damage and the need for extensive revision surgery.
Collapse
|
29
|
Jonker RC, van Beers LWAH, van der Wal BCH, Vogely HC, Parratte S, Castelein RM, Poolman RW. Can dual mobility cups prevent dislocation without increasing revision rates in primary total hip arthroplasty? A systematic review. Orthop Traumatol Surg Res 2020; 106:509-517. [PMID: 32278733 DOI: 10.1016/j.otsr.2019.12.019] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/16/2019] [Revised: 12/22/2019] [Accepted: 12/29/2019] [Indexed: 02/03/2023]
Abstract
BACKGROUND Dislocation is one of the leading causes for early revision surgery after total hip arthroplasty (THA). To address this problem, the dual mobility (DM) cup was developed in the 1970s by the French. Despite the increased and, in some countries, broad use of DM cups, high quality evidence of their effectiveness compared to traditional unipolar (UP) cups is lacking. There are a few well-conducted literature reviews, but the level of evidence of the included studies was moderate to low and the rates of revision were not specifically investigated. Therefore, we did a systematic review to investigate whether there is a difference in the rate of dislocations and revisions after primary THA with a DM cup or a UP cup. METHODS We conducted a systematic literature search in PubMed, Embase and Cochrane databases in July 2019. The articles were selected based upon their quality, relevance and measurement of the predictive factor. We used the MINORS criteria to determine the methodological quality of all studies. RESULTS The initial search resulted in 702 citations. After application of the inclusion and exclusion criteria, eight articles met our eligibility criteria and were graded. Included studies were of medium to low methodological quality with a mean score of 14/24 (11-16) points following the MINORS criteria. In the case-control studies, a total of 549 DM cups and 649 UP cups were included. In the registry studies, a total of 5.935 DM cups and 217.362 UP cups were included. In the case-control studies, one (0.2%) dislocation was reported for the DM cups and 46 (7.1%) for the UP cup (p=0.009, IQR=0.00-7.00). Nine (1.6%) revisions, of which zero due to dislocation, were reported for the DM cup and 39 (6.0%), of which 30 due to dislocation, for the UP cup (p=0.046, CI=-16.93-5.73). In the registry studies 161 (2.7%) revisions were reported for the DM cup, of which 14 (8.7%) due to dislocation. For the UP cup, 3.332 (1.5%) revisions were reported (p=0.275, IQR=41.00-866.25), of which 1.093 (32.8%) due to dislocation (p=0.050, IQR=3.50-293.25). CONCLUSION This review suggests lower rates of dislocation and lower rates of revision for dislocation in favor of the DM cups. Concluding, DM cups might be an effective solution to reduce dislocation in primary THA. To evaluate the efficacy of DM cups compared to UP cups, an economic evaluation alongside a randomized controlled trial is needed focusing on patient important endpoints. LEVEL OF EVIDENCE III, systematic review of level III studies.
Collapse
Affiliation(s)
- Ragna C Jonker
- Department of Orthopaedic Surgery, University Medical Center Utrecht, PO Box 85500, 3508 GA Utrecht, The Netherlands.
| | - Loes W A H van Beers
- Department of Orthopaedic Surgery, OLVG, PO Box 95500, 1090 HM Amsterdam, The Netherlands
| | - Bart C H van der Wal
- Department of Orthopaedic Surgery, University Medical Center Utrecht, PO Box 85500, 3508 GA Utrecht, The Netherlands
| | - H Charles Vogely
- Department of Orthopaedic Surgery, University Medical Center Utrecht, PO Box 85500, 3508 GA Utrecht, The Netherlands
| | - Sebastien Parratte
- Department of Orthopedic Surgery and Traumatology, St. Marguerite Hospital Marseille, 270 Boulevard de Sainte-Marguerite, 13009 Marseille, France
| | - René M Castelein
- Department of Orthopaedic Surgery, University Medical Center Utrecht, PO Box 85500, 3508 GA Utrecht, The Netherlands
| | - Rudolf W Poolman
- Department of Orthopaedic Surgery, OLVG, PO Box 95500, 1090 HM Amsterdam, The Netherlands; Department of Orthopaedic Surgery, Leiden University Medical Center, PO Box 9600, 2300 RC Leiden, The Netherlands
| |
Collapse
|
30
|
Laende EK, Richardson CG, Dunbar MJ. Migration and Wear of a Dual Mobility Acetabular Construct at 3 Years Measured by Radiostereometric Analysis. J Arthroplasty 2020; 35:1109-1116. [PMID: 31866254 DOI: 10.1016/j.arth.2019.11.010] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/08/2019] [Revised: 10/27/2019] [Accepted: 11/07/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The anatomic dual mobility (ADM) acetabular component was introduced because of previously described low dislocation rates for this type of construct. The shape of the anatomic cup and the motion of polyethylene liner may have implications for acetabular cup fixation and polyethylene liner wear; therefore, the purpose of this study was to assess the migration patterns and wear rates of the ADM component using radiostereometric analysis. METHODS Uncemented ADM acetabular components were implanted in 27 patients. Radiostereometric analysis exams were taken at 6 follow-up visits over 3 years. Proximal translation and sagittal rotation of the cup and polyethylene total wear and wear rates were calculated. Oxford 12 Hip scores and satisfaction were recorded. RESULTS Mean proximal translation was below the 0.2 mm threshold at 2 years associated with acceptable long-term survivorship (0.16 mm [standard deviation {SD} 0.31] at 3 years). Mean sagittal rotation was 0.29 degrees (SD 1.03) and was greater in female subjects (P < .001). Following bedding-in, the annual wear rate was 0.02 mm/y, below the 0.1 mm/y threshold. There was no association between cup migration and polyethylene wear. Patient satisfaction at 3 years was 96%. Mean Oxford 12 Hip scores improved from 21 (SD 7) preoperatively to 43 (SD 7) 3 years postoperatively. CONCLUSIONS The ADM cup demonstrated stable migration at 3 years indicating low risk for aseptic loosening. Bedding-in in the first year was followed by low annual wear rates. These finding suggest no increased risk of the dual mobility and anatomic design on fixation or wear.
Collapse
Affiliation(s)
- Elise K Laende
- Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada; School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada
| | - C Glen Richardson
- Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada
| | - Michael J Dunbar
- Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada; School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada
| |
Collapse
|
31
|
Castiello E, Amendola L, Barca P, Tigani D, Caton JH, Neri T, Prudhon JL. Letter to the editor on "Asymptomatic intraprosthetic dual mobility cup dislocation with increased metal ion levels". Arthroplast Today 2020; 6:132-133. [PMID: 32211491 PMCID: PMC7083734 DOI: 10.1016/j.artd.2020.01.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/30/2019] [Revised: 01/03/2020] [Accepted: 01/06/2020] [Indexed: 11/24/2022] Open
Affiliation(s)
- Emanuela Castiello
- Department of Orthopaedic Surgey, Ospedale Maggiore "Carlo Alberto Pizzardi", Bologna, Italy
| | - Luca Amendola
- Department of Orthopaedic Surgey, Ospedale Maggiore "Carlo Alberto Pizzardi", Bologna, Italy
| | - Paolo Barca
- Department of Orthopaedic Surgey, Ospedale Maggiore "Carlo Alberto Pizzardi", Bologna, Italy
| | - Domenico Tigani
- Department of Orthopaedic Surgey, Ospedale Maggiore "Carlo Alberto Pizzardi", Bologna, Italy
| | | | - Thomas Neri
- Department of Orthopaedic Surgery, University Hospital Centre of Saint-Etienne, EA 7424 - Inter-University Laboratory of Human Movement Science, University Lyon, University Jean Monnet, Saint Etienne, France
| | | |
Collapse
|
32
|
Koper MC, Bos K. Response to letter to the editor on “Asymptomatic intraprosthetic dual mobility cup dislocation with increased metal ion levels”. Arthroplast Today 2020; 6:134-135. [PMID: 32211492 PMCID: PMC7083732 DOI: 10.1016/j.artd.2020.01.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2019] [Revised: 12/27/2019] [Accepted: 01/06/2020] [Indexed: 11/28/2022] Open
|
33
|
Pedneault C, Tanzer D, Nooh A, Smith K, Tanzer M. Capsular closure outweighs head size in preventing dislocation following revision total hip arthroplasty. Hip Int 2020; 30:141-146. [PMID: 31074310 DOI: 10.1177/1120700019848107] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION The high dislocation rate following revision total hip arthroplasty (THA) has been shown to be significantly reduced by closing the posterior capsule and by the use of large diameter femoral heads. The relative importance of each of these strategies on the rate of dislocation remains unknown. We undertook a study to determine if increasing femoral head diameter, in addition to posterior capsular closure would influence the dislocation rate following revision THA. METHODS We retrospectively reviewed 144 patients who underwent a revision THA. We included all patients who underwent revision THA with closure of the posterior capsule and who had at least a 2-year minimum follow-up. 48 patients had a 28-mm femoral head, 47 had a 32-mm head and 49 patients had a 36-mm femoral head. RESULTS At a minimum follow-up of 2 years, there were 3 dislocations. There were no dislocations in the 28-mm group (0%), 2 in the 32-mm group (4%) and 1 in the 36-mm group (2%). Head size alone was not found to significantly decrease the risk of dislocation (28-mm versus 32-mm p = 0.12; 28-mm versus 36-mm p = 0.27; 32-mm versus 36-mm p = 0.40). CONCLUSION Both large diameter heads and careful attention to surgical technique with posterior capsular closure can decrease the historically high dislocation rate after revision THA when utilising the posterolateral approach. Capsular closure outweighs the effect of femoral head diameter in preventing dislocation following revision THA through a posterolateral approach.
Collapse
Affiliation(s)
| | - Dylan Tanzer
- Jo Miller Orthopaedic Laboratory, Research Institute of the McGill University, Montreal, Canada
| | - Anas Nooh
- Division of Orthopaedic Surgery, McGill University, Montreal, Canada
| | - Karen Smith
- Jo Miller Orthopaedic Laboratory, Research Institute of the McGill University, Montreal, Canada
| | - Michael Tanzer
- Division of Orthopaedic Surgery, McGill University, Montreal, Canada
| |
Collapse
|
34
|
Lack of early dislocation for dual mobility vs. fixed bearing total hip arthroplasty: A multi-center analysis of comparable cohorts. J Orthop 2020; 21:1-5. [PMID: 32071524 DOI: 10.1016/j.jor.2020.02.006] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/30/2020] [Accepted: 02/02/2020] [Indexed: 02/06/2023] Open
Abstract
Background Dislocation is a major cause of morbidity and revision surgery following total hip arthroplasty (THA). To address such issues, dual mobility (DM) bearings were introduced as a more stable alternative to fixed-bearing (FB) prostheses. As such, we compared DM and FB systems in a cohort study in terms of dislocations, readmissions, and revisions. Methods A 27 multi-center retrospective review was performed of 664 DM and 218 FB cases from the same manufacturer with mean follow-up of 2.09 years and 1.83 years, respectively. Patient reported outcome measures (PROMs) including Harris Hip Score (HHS), SF12, EQ5D, and Lower Extremity Activity Score (LEAS) were evaluated as well as dislocation rates, readmissions, and revisions rates. We also performed a survivorship analysis through Kaplan-Meier estimator. Students t-test was used for normally distributed continuous data and Fisher exact test (P < 0.05) was used for discrete data. Results There were 0 dislocations in the DM (0%) group and 2 dislocations in the FB (0.92%) group (p = 0.06). Latest follow up HHS revealed a significant difference between groups (91.44 DM and 87.81 FB; p = 0.006). In addition, there was significant difference between DM and FB on SF12 Physical Component Score (PCS) (46.83 and 44.55, respectively, p = 0.015). Also, readmission rates at 30, 60 and 90 days remained lower for DM than for FB at each time point (1.05% vs. 2.75%, 1.81% vs. 2.75%, and 1.81% vs. 2.75, respectively). Overall, DM had a lower revision rate at 1.51% compared to 2.29% for FB (p = 0.24). The revision breakdown for DM revealed 0 (0%) for both Anatomic Dual Mobility (ADM) and Modular Dual Mobility (MDM) due to the acetabular component.) There was a difference, 14 (87.5%) for ADM and 2 (12.5%) due to the femoral component. The survivorship analysis revealed no significance difference between DM and FB at 4 years (97.90% and 97.26%, respectively). Conclusion In comparison to patients who undergo FB THA, DM bearings have improved PROMs and a lower rate of dislocation, readmission, and revision.
Collapse
|
35
|
Sayac G, Neri T, Schneider L, Philippot R, Farizon F, Boyer B. Low Revision Rates at More Than 10 Years for Dual-Mobility Cups Cemented Into Cages in Complex Revision Total Hip Arthroplasty. J Arthroplasty 2020; 35:513-519. [PMID: 31543421 DOI: 10.1016/j.arth.2019.08.058] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2019] [Revised: 08/07/2019] [Accepted: 08/26/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Instability and aseptic loosening are the two main complications after revision total hip arthroplasty (rTHA). Dual-mobility (DM) cups were shown to counteract implant instability during rTHA. To our knowledge, no study evaluated the 10-year outcomes of rTHA using DM cups, cemented into a metal reinforcement ring, in cases of severe acetabular bone loss. We hypothesized that using a DM cup cemented into a metal ring is a reliable technique for rTHA at 10 years, with few revisions for acetabular loosening and/or instability. METHODS This is a retrospective study of 77 rTHA cases with severe acetabular bone loss (Paprosky ≥ 2C) treated exclusively with a DM cup (NOVAE STICK; Serf, Décines-Charpieu, France) cemented into a cage (Kerboull cross, Burch-Schneider, or ARM rings). Clinical scores and radiological assessments were performed preoperatively and at the last follow-up. The main endpoints were revision surgery for aseptic loosening or recurring dislocation. RESULTS With a mean follow-up of 10.7 years [2.1-16.2], 3 patients were reoperated because of aseptic acetabular loosening (3.9%) at 9.6 years [7-12]. Seven patients (9.45%) dislocated their hip implant, only 1 suffered from chronic instability (1.3%). Cup survivorship was 96.1% at 10 years. No sign of progressive radiolucent lines were found and bone graft integration was satisfactory for 91% of the patients. CONCLUSION The use of a DM cup cemented into a metal ring during rTHA with complex acetabular bone loss was associated with low revision rates for either acetabular loosening or chronic instability at 10 years.
Collapse
Affiliation(s)
- Gary Sayac
- Department of Orthopaedic Surgery, University Hospital Centre of Saint-Etienne, Saint-Etienne, France
| | - Thomas Neri
- Department of Orthopaedic Surgery, University Hospital Centre of Saint-Etienne, Saint-Etienne, France; EA 7424 - Inter-university Laboratory of Human Movement Science, University Lyon, University Jean Monnet, Saint-Etienne, France
| | - Loïc Schneider
- Department of Orthopaedic Surgery, Clinique Mutualiste of Saint-Etienne, Saint-Etienne, France
| | - Rémi Philippot
- Department of Orthopaedic Surgery, University Hospital Centre of Saint-Etienne, Saint-Etienne, France; EA 7424 - Inter-university Laboratory of Human Movement Science, University Lyon, University Jean Monnet, Saint-Etienne, France
| | - Frédéric Farizon
- Department of Orthopaedic Surgery, University Hospital Centre of Saint-Etienne, Saint-Etienne, France; INSERM U1059 (SAINBIOSE), University Jean Monnet, Saint-Etienne, France
| | - Bertrand Boyer
- Department of Orthopaedic Surgery, University Hospital Centre of Saint-Etienne, Saint-Etienne, France; INSERM U1059 (SAINBIOSE), University Jean Monnet, Saint-Etienne, France
| |
Collapse
|
36
|
Early results of revision dual mobility uncemented cups with impaction autologous and synthetic bone graft composite in revision hip arthroplasty for cavitary acetabular defects: A retrospective case series. CURRENT ORTHOPAEDIC PRACTICE 2019. [DOI: 10.1097/bco.0000000000000818] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
37
|
Dubin JA, Westrich GH. Anatomic dual mobility compared to modular dual mobility in primary total hip arthroplasty: a matched cohort study. Arthroplast Today 2019; 5:509-514. [PMID: 31886399 PMCID: PMC6920720 DOI: 10.1016/j.artd.2019.09.006] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2019] [Revised: 09/17/2019] [Accepted: 09/17/2019] [Indexed: 01/19/2023] Open
Abstract
Background Dual mobility (DM) has been used in primary total hip arthroplasty recently for their low dislocation rates, low revision rates, and improved patient functional outcomes. We compared 2 DM systems, anatomic dual mobility (ADM; Stryker, Mahwah, NJ) and modular dual mobility (MDM; Stryker, Mahwah, NJ), to determine differences in dislocation rates, revision rates, and patient outcome scores. Methods The study was a single-center matched retrospective review of prospectively collected data of patients who underwent primary total hip arthroplasty surgery with an ADM or MDM system by a single surgeon from 2012 to 2017. Demographics, operative details, postoperative patient-reported outcomes, and clinical outcomes were recorded. A Kaplan-Meier survivorship curve to compare survival time between groups was collected as well. Results Five hundred seventy-four patients were included in the study with 287 patients matched in each group with mean 2.86 years of follow-up. The dislocation rate in each cohort was 0%, the acetabular-specific revision rate was 0%, and in each cohort, overall revision rate in each cohort was 1.7%. In general, patient-reported outcomes were similar for each group (Harris Hip Score Pain (P = .919), Harris Hip Score Function (P = .736), Western Ontario and McMaster Universities Osteoarthritis Index (P = .139), Pain Visual Analog Scale (P = .146), Veterans RAND 12-Item Health Survey (P = .99), University of California, Los Angeles (P = .417), and Harris Hip Score Total (P = .136). There was a slight clinically insignificant increase in hip flexion between the cohorts favoring the ADM group (98.6 ± 9.8 vs 94.0 ± 9.7, P < .001). Conclusions Both DM systems had similar patient-reported outcomes that were quite favorable. At 2.86 years of follow-up, neither the ADM nor MDM systems demonstrated dislocation, and both had low acetabular-specific and overall revision rates in this matched cohort study.
Collapse
Affiliation(s)
- J A Dubin
- Department of Orthopedic Surgery, Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, NY, USA
| | - G H Westrich
- Department of Orthopedic Surgery, Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, NY, USA
| |
Collapse
|
38
|
de l'Escalopier N, Dumaine V, Auberger G, Babinet A, Courpied JP, Anract P, Hamadouche M. Dual mobility constructs in revision total hip arthroplasty: survivorship analysis in recurrent dislocation versus other indications at three to twelve-year follow-up. INTERNATIONAL ORTHOPAEDICS 2019; 44:253-260. [PMID: 31758218 DOI: 10.1007/s00264-019-04445-4] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2019] [Accepted: 10/21/2019] [Indexed: 01/15/2023]
Abstract
BACKGROUND The aim of this retrospective study was to evaluate the clinical, radiologic, and survival results of dual mobility (DM) sockets in revision total hip arthroplasty (THA) performed for instability versus revision THAs performed for other reasons. METHODS From a computerized database, we identified 84 revision THAs using a modern DM socket performed in 81 patients with a mean age of 71 years. Indication for revision was recurrent dislocation in 47 hips, and other reasons in the remaining 37 hips. A survivorship analysis according to the actuarial method was carried out on the entire series using revision for any cause, revision for dislocation, and radiological cup loosening revised or not, as the end points. RESULTS Of the 81 patients, twelve died, six were lost to follow-up, eight had been revised, and 55 patients (58 hips) were unrevised and alive at a mean follow-up of 6.4 years. Dislocation occurred in four of the 47 (8.5%) hips for which indication for revision was dislocation versus one of the remaining 37 (2.7%) hips [odds ratio = 3.4 (0.4-31.3), p = 0.07]. According to our criteria, three acetabular components of which one was revised were considered as loosened. When using revision for dislocation as the end-point, the survival rate at seven years was 90.4 ± 5.3% (IC95%, 79.9-100) in the 47 hips for which the indication for revision was dislocation versus 100% in the remaining 37 hips (log-rank, p = 0.5). CONCLUSIONS The current study indicated that DM sockets represent an interesting solution to prevent dislocation in revision THAs at mid-term follow-up.
Collapse
Affiliation(s)
- Nicolas de l'Escalopier
- Clinical Orthopaedics Research Center, Department of Orthopaedic and Reconstructive Surgery, Hôpitaux Universitaires Paris Centre (HUPC), Site Cochin-Port Royal, Assitance Publique-Hôpitaux de Paris (AP-HP), Université Paris 5, 27 Rue du Faubourg St Jacques, 75014, Paris, France.
| | - Valérie Dumaine
- Clinical Orthopaedics Research Center, Department of Orthopaedic and Reconstructive Surgery, Hôpitaux Universitaires Paris Centre (HUPC), Site Cochin-Port Royal, Assitance Publique-Hôpitaux de Paris (AP-HP), Université Paris 5, 27 Rue du Faubourg St Jacques, 75014, Paris, France
| | - Guillaume Auberger
- Clinical Orthopaedics Research Center, Department of Orthopaedic and Reconstructive Surgery, Hôpitaux Universitaires Paris Centre (HUPC), Site Cochin-Port Royal, Assitance Publique-Hôpitaux de Paris (AP-HP), Université Paris 5, 27 Rue du Faubourg St Jacques, 75014, Paris, France
| | - Antoine Babinet
- Clinical Orthopaedics Research Center, Department of Orthopaedic and Reconstructive Surgery, Hôpitaux Universitaires Paris Centre (HUPC), Site Cochin-Port Royal, Assitance Publique-Hôpitaux de Paris (AP-HP), Université Paris 5, 27 Rue du Faubourg St Jacques, 75014, Paris, France
| | - Jean-Pierre Courpied
- Clinical Orthopaedics Research Center, Department of Orthopaedic and Reconstructive Surgery, Hôpitaux Universitaires Paris Centre (HUPC), Site Cochin-Port Royal, Assitance Publique-Hôpitaux de Paris (AP-HP), Université Paris 5, 27 Rue du Faubourg St Jacques, 75014, Paris, France
| | - Philippe Anract
- Clinical Orthopaedics Research Center, Department of Orthopaedic and Reconstructive Surgery, Hôpitaux Universitaires Paris Centre (HUPC), Site Cochin-Port Royal, Assitance Publique-Hôpitaux de Paris (AP-HP), Université Paris 5, 27 Rue du Faubourg St Jacques, 75014, Paris, France
| | - Moussa Hamadouche
- Clinical Orthopaedics Research Center, Department of Orthopaedic and Reconstructive Surgery, Hôpitaux Universitaires Paris Centre (HUPC), Site Cochin-Port Royal, Assitance Publique-Hôpitaux de Paris (AP-HP), Université Paris 5, 27 Rue du Faubourg St Jacques, 75014, Paris, France
| |
Collapse
|
39
|
Huten D, Fournier Y, Gicquel T, Bertho P, Basselot F, Hamadouche M. Risk factors for dislocation after revision total hip arthroplasty with a dual-mobility cup. Matched case-control study (16 cases vs. 48 controls). Orthop Traumatol Surg Res 2019; 105:1303-1309. [PMID: 31153859 DOI: 10.1016/j.otsr.2019.01.020] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/15/2018] [Revised: 01/15/2019] [Accepted: 01/28/2019] [Indexed: 02/02/2023]
Abstract
BACKGROUND Reports of high dislocation rates after revision total hip arthroplasty (THA) have encouraged the widespread use of dual-mobility cups. Dislocation has been less common but not fully abolished with dual-mobility cups, and its causes have remained unidentified. The objectives of this retrospective matched case-control study were: 1) to identify risk factors for dislocation, 2) and to assess dislocation outcomes. HYPOTHESIS The causes of dislocation after revision THA with a dual-mobility cup can be identified. MATERIAL AND METHOD Among 653 consecutive patients identified retrospectively as having undergone revision THA with a dual-mobility cup (Medial Cup, Aston, Saint-Étienne, France) between January 2007 and December 2017, 16 (2.45%) subsequently experienced dislocation, after a mean of 3.6 months (range, 0.9-19 months). For each of these 16 patients, we collected the main patient characteristics (age, sex, body mass index [BMI], ASA score, and reason for the initial arthroplasty procedure), local history (number of previous surgical procedures, reason for revision, femoral and acetabular bony defects classified according to Paprosky, and status of the abductor apparatus), and characteristics of the revision (approach, diameters of the cup and femoral head, cup inclination, femoral offset, lower limb length, and implant anteversion). Controls were patients without dislocation after revision dual-mobility THA. Each of the 16 patients was matched to 3 controls on age (±10 years), sex, year of revision, and whether revision was only acetabular or bipolar. Univariate and multivariate analyses were done to compare the cases and controls, and dislocation outcomes in the cases were evaluated. RESULTS By univariate analyses, factors associated with dislocation were BMI>30 (cases, 37.5%; controls, 10.4%; p=0.02), larger number of previous surgical procedures on the same hip (cases, 2.8; controls, 1.8; p=0.004), larger number of arthroplasties (cases, 2.3; controls, 1.5; p=0.004), history of instability (cases, 31% with chronic dislocation and 13% with recurrent dislocation; controls, 6.25% and 2.1%, respectively; p=0.004), and compromised abductor apparatus (cases, 56.25%; controls, 14.6%; p=0.002). Independent risk factors for dislocation identified by multivariate analysis were instability (odds ratio [OR], 14.5; 95% confidence interval [95%CI], 1.5-149.9) and, most importantly, abductor apparatus compromise (OR, 43.1; 95%CI, 3.18-586.3). Of the 16 cases, 1 was lost to follow-up, 1 had contra-indications to anaesthesia, 1 died after several dislocation episodes, and 1 died 3 months after surgical reduction. In 5 cases, there was a single dislocation episode. Further surgery was performed in 8 cases (surgical reduction, n=1; constrained cup, n=3; trochanteric internal fixation, n=1; exchange of the dual-mobility cup, n=2, including 1 with subsequent dislocation episodes; and femoral component exchange followed by a retentive cup due to further dislocation episodes, n=1). CONCLUSION Risk factors for dislocation consisted of a history of instability and, most importantly, abductor apparatus compromise. A constrained cup should be considererd in patients with impaired abductor apparatus. No further dislocations occurred after reduction of the first episode in 31.25% of cases. Recurrent dislocation should prompt measures to correct impaired abductor apparatus whenever possible, as well as correction of any component malposition. Whether a retentive cup should be implanted routinely remains unclear. LEVEL OF EVIDENCE III, matched case-control study.
Collapse
Affiliation(s)
- Denis Huten
- Service de chirurgie orthopédique et réparatrice de l'appareil moteur du CHU de Rennes, hôpital Pontchaillou, 2, rue Henri-le-Guilloux, 35000 Rennes, France.
| | - Yohann Fournier
- Service de chirurgie orthopédique et réparatrice de l'appareil moteur du CHU de Rennes, hôpital Pontchaillou, 2, rue Henri-le-Guilloux, 35000 Rennes, France
| | - Thomas Gicquel
- Service de chirurgie orthopédique et réparatrice de l'appareil moteur du CHU de Rennes, hôpital Pontchaillou, 2, rue Henri-le-Guilloux, 35000 Rennes, France
| | - Pierre Bertho
- Service de chirurgie orthopédique et réparatrice de l'appareil moteur du CHU de Rennes, hôpital Pontchaillou, 2, rue Henri-le-Guilloux, 35000 Rennes, France
| | - Frédéric Basselot
- Service de chirurgie orthopédique et réparatrice de l'appareil moteur du CHU de Rennes, hôpital Pontchaillou, 2, rue Henri-le-Guilloux, 35000 Rennes, France
| | - Moussa Hamadouche
- Service d'orthopédie de l'hôpital Cochin, AP-HP, 27, rue du Faubourg Saint-Jacques, 75014 Paris, France
| |
Collapse
|
40
|
Abstract
Hip instability following total hip arthroplasty (THA) remains a major challenge and is one of the main causes of revision surgery. Dual mobility (DM) implants have been introduced to try to overcome this problem. The DM design consists of a small femoral head captive and mobile within a polyethylene liner. Numerous studies have shown that DM implants reduce the rate of dislocation compared to fixed-bearing inserts. Early designs for DM implants had problems with wear and intra-prosthetic dislocations, so their use was restricted to limited indications. The results of the latest generation of DM prostheses demonstrate that these problems have been overcome. Given the results of these studies presented in this review, surgeons may now consider DM THA for a wider patient selection.
Cite this article: EFORT Open Rev 2019;4:541-547. DOI: 10.1302/2058-5241.4.180045
Collapse
Affiliation(s)
- William G Blakeney
- Department of Surgery, CIUSSS-de-L'Est-de-L'Ile-de-Montréal, Hôpital Maisonneuve Rosemont, Montréal, Québec, Canada.,Department of Surgery, Albany Health Campus, Albany, Australia
| | | | - Pascal-André Vendittoli
- Department of Surgery, Albany Health Campus, Albany, Australia.,Department of Surgery, Université de Montréal, Montréal, Québec, Canada
| |
Collapse
|
41
|
Dikmen G, Ozden VE, Karaytug K, Tozun R. Dual-mobility cups in revision acetabular reconstructions: Short-term outcomes in high-risk patients for instability. ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA 2019; 53:329-333. [PMID: 31281078 PMCID: PMC6819842 DOI: 10.1016/j.aott.2019.05.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/11/2018] [Revised: 04/25/2019] [Accepted: 05/24/2019] [Indexed: 02/07/2023]
Abstract
Objective The aim of this study was to evaluate the performance of dual-mobility (DM) cup systems for revision total hip arthroplasty (rTHA) in patients who had high risk for instability. Methods We prospectively followed up 34 hips of 30 patients (27 females, 3 males; mean age: 66.1 (range: 33 to 89) years) who underwent rTHA with DM cups for aseptic loosening in 23 hips, infection treatment as second or single stage in nine hips, and instability in two hips. Clinical functions of the patients were evaluated using the Harris Hip Score (HHS), and radiological migration or loosening of the DM cups were recorded. The survival of the components was calculated with the Kaplan-Meier survival analysis and failure was defined as any dislocation of the polyethylene (PE) insert, intraprosthetic dislocation (IPD), aseptic loosening of any component or total hip system revision due to any reason. Results The mean duration of follow-up was 3.52 (range: 2.05 to 6.26) years. There was one dislocation of PE insert (2.9%), which was treated with closed reduction. There were two (5.8%) re-revisions for cemented DM cup due to migration. There was one PE insert and head change due to subacute infection. The mean HHS increased from 42.8 ± 6.7 (range: 34 to 60) points preoperatively to 87.3 ± 5.8 (range: 75 to 98) points postoperatively. The cumulative survival rate of the DM cup system was 91.2% (95% CI: 81.6–100%) with any revision, 94.1% (95% CI: 86.2–100%) with aseptic loosening and %97.1 (%95 CI: 91.4–100%) with dislocation as the end point at 3.5 years. Conclusion Dual-mobility cups may provide good stability and represent a good option for revision acetabular reconstruction in patients who have high risk for instability. Level of evidence Level IV, therapeutic study.
Collapse
|
42
|
Huang RC, Malkani AL, Harwin SF, Hozack WJ, Mont MA, Higuera-Rueda CA, Westrich GH. Multicenter Evaluation of a Modular Dual Mobility Construct for Revision Total Hip Arthroplasty. J Arthroplasty 2019; 34:S287-S291. [PMID: 31005430 DOI: 10.1016/j.arth.2019.03.027] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/09/2018] [Revised: 03/07/2019] [Accepted: 03/10/2019] [Indexed: 02/01/2023] Open
Abstract
INTRODUCTION Modular Dual Mobility (MDM) constructs in total hip arthroplasty (THA) offer increased hip stability compared with constrained liners, without compromising hip range of motion. The purpose of this study was to evaluate outcomes of revision THA using MDM. METHODS The study was a multiinstitutional retrospective cohort study of 315 hips that underwent revision THA using MDM between 2011 and 2017. Clinical outcomes and reasons for failure were collected. RESULTS Three hundred fifteen patients met 1-year minimum follow-up (mean 3.3 years). Nine hips had instability postoperatively (2.9%), and 30 hips required reoperation (9.5%). Seven had recurrent instability (6.5%) which was associated with liner-only exchange (P = .021) and liner outer diameter of ≤ 38 mm (P = .016). CONCLUSION Revision THA with MDM provided a low rate of instability and reoperation in a revision cohort. Recurrent instability following use of MDM in revision THA was associated with retention of the acetabular component and polyethylene outer diameter ≤ 38 mm. LEVEL OF EVIDENCE Therapeutic Level III.
Collapse
Affiliation(s)
- Ronald C Huang
- Hospital for Special Surgery, Adult Reconstruction and Joint Replacement, New York, NY; Department of Orthopedic Surgery, BronxCare Health Systems, Bronx, NY
| | | | - Steven F Harwin
- Department of Orthopedics, Mt. Sinai West Hospital, New York, NY
| | | | - Michael A Mont
- Department of Orthopedics, Cleveland Clinic, Cleveland, OH; Department of Orthopaedic Surgery, Lenox Hill at Northwell, New York, NY
| | | | - Geoffrey H Westrich
- Hospital for Special Surgery, Adult Reconstruction and Joint Replacement, New York, NY
| |
Collapse
|
43
|
John R, Jain A, Agarwal S, Thomas S, Agarwal S. Dissociation of Cemented Dual Mobility Socket from the Acetabulum in A Case of Recurrent Total Hip Arthroplasty Instability -A Novel Complication. J Orthop Case Rep 2019; 8:46-49. [PMID: 30915293 PMCID: PMC6424319 DOI: 10.13107/jocr.2250-0685.1252] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Introduction: Acute complete dissociation of a cemented socket from the acetabular cavity is very rare and has been described only in relation to closed reduction maneuver of a dislocated hip arthroplasty. Case Report: We present a case of recurrent hip dislocation in a 70-year-old female post total hip arthroplasty for which a cemented dual mobility (DM) component was used. The cemented socket dissociated from the acetabular cavity with the polyethylene liner insitul-year post- surgery. It was not related to intraprosthetic dislocation as the acetabular liner-socket interface was not disrupted. A re-revision of the acetabular component was done with an acetabular reinforcement cage, cemented cup, and constraint acetabular liner. No such case of cup dissociation has been reported in the literature till date. Conclusion: The use of cemented DM cups without acetabular reinforcement devices has been described recently and is still controversial. Surgeons should be aware of the possibility of such a complication when using metal-backed cemented DM cups.
Collapse
Affiliation(s)
- Rakesh John
- Department of Orthopaedics, Sant Parmanand Hospital, Civil Lines, New Delhi, India
| | - Anuj Jain
- Department of Orthopaedics, Sant Parmanand Hospital, Civil Lines, New Delhi, India
| | - Shekhar Agarwal
- Department of Orthopaedics, Sant Parmanand Hospital, Civil Lines, New Delhi, India
| | - Simon Thomas
- Department of Orthopaedics, Sant Parmanand Hospital, Civil Lines, New Delhi, India
| | - Sunny Agarwal
- Department of Orthopaedics, Sant Parmanand Hospital, Civil Lines, New Delhi, India
| |
Collapse
|
44
|
Plummer D, Passen E, Alexander J, Vajapey S, Frantz T, Niedermeier S, Pettit R, Scharschmidt T. Rapid return to function and stability with dual mobility components cemented into an acetabular reconstructive cage for large osseous defects in the setting of periacetabular metastatic disease. J Surg Oncol 2019; 119:1155-1160. [PMID: 30908659 DOI: 10.1002/jso.25463] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2018] [Revised: 02/25/2019] [Accepted: 03/04/2019] [Indexed: 12/30/2022]
Abstract
BACKGROUND AND OBJECTIVES Large acetabular defects secondary to metastatic disease frequently require extensive acetabular reconstruction. Techniques of acetabular reconstruction have been described, but no consensus for the management of these defects has been reached so far. We present our technique and patient outcomes for acetabular reconstruction by cementing a dual mobility cup into an acetabular cage. METHODS We reviewed 152 total hip arthroplasties and identified 19 patients with periacetabular metastatic disease and large defects who required acetabular reconstruction utilizing a dual mobility cup cemented into an acetabular reconstructive cage. The following outcomes were evaluated: pain relief, functional improvement, postoperative complications. RESULTS Mean follow-up was 3 years, with 13 of the 19 patients eligible for 2-year follow-up. Patients reported a significant improvement in both pain and functional outcomes. There were no dislocations or signs of loosening. Two patients developed postoperative infections. One patient required hemipelvectomy 16 months postop due to recurrence of metastatic disease. CONCLUSIONS Cementing a dual mobility cup into an acetabular cage provides a highly stable and durable option for patients with periacetabular metastatic disease and large defects. Patients are able to return to immediate full weight bearing with significant improvement in both function and pain at 2 years.
Collapse
Affiliation(s)
- Darren Plummer
- Department of Orthopaedic Surgery, The Ohio State University, Columbus, Ohio
| | - Edward Passen
- Department of Orthopaedic Surgery, Heritage College of Osteopathic Medicine, Ohio University, Athens, Ohio
| | - John Alexander
- Department of Orthopaedic Surgery, The Ohio State University, Columbus, Ohio
| | - Sravya Vajapey
- Department of Orthopaedic Surgery, The Ohio State University, Columbus, Ohio
| | - Travis Frantz
- Department of Orthopaedic Surgery, The Ohio State University, Columbus, Ohio
| | - Steven Niedermeier
- Department of Orthopaedic Surgery, The Ohio State University, Columbus, Ohio
| | - Robert Pettit
- Department of Orthopaedic Surgery, The Ohio State University, Columbus, Ohio
| | - Thomas Scharschmidt
- Department of Orthopaedic Surgery, The Ohio State University, Columbus, Ohio
| |
Collapse
|
45
|
Kreipke R, Rogmark C, Pedersen AB, Kärrholm J, Hallan G, Havelin LI, Mäkelä K, Overgaard S. Dual Mobility Cups: Effect on Risk of Revision of Primary Total Hip Arthroplasty Due to Osteoarthritis: A Matched Population-Based Study Using the Nordic Arthroplasty Register Association Database. J Bone Joint Surg Am 2019; 101:169-176. [PMID: 30653047 DOI: 10.2106/jbjs.17.00841] [Citation(s) in RCA: 45] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND The dual mobility acetabular cup (DMC) was designed to reduce prosthetic instability and has gained popularity for both primary and revision total hip arthroplasty (THA). We compared the risk of revision of primary THA for primary osteoarthritis between patients treated with a DMC and those who received a metal-on-polyethylene (MoP) or ceramic-on-polyethylene (CoP) bearing. METHODS A search of the Nordic Arthroplasty Register Association (NARA) database identified THAs performed with a DMC during 1995 to 2013. With use of propensity score matching, 2,277 of these patients were matched (1:1), with regard to sex, age, component fixation, and year of surgery, with patients with an MoP or CoP bearing. We estimated the cumulative incidence of revision taking death as a competing risk into consideration and performed competing risk regression with revision or death as end points. RESULTS There was no difference in the overall risk of revision between the DMC group and the propensity-score-matched MoP/CoP group (adjusted hazard ratio [HR] = 1.18; 95% confidence interval [95% CI] = 0.87 to 1.62). Patients with a DMC bearing had a lower risk of revision due to dislocation (adjusted HR = 0.09; 95% CI = 0.03 to 0.29) but a higher risk of revision caused by infection (adjusted HR = 3.20; 95% CI = 1.49 to 6.85). CONCLUSIONS There was no difference in overall risk of revision between the DMC and MoP/CoP groups. The DMCs protected against revision due to dislocation but THAs performed with this bearing were more commonly revised because of infection. There may have been a selection bias toward placing DMC implants in patients with greater frailty as the mortality rates were higher in the DMC group than in the age and sex-matched MoP/CoP group. LEVEL OF EVIDENCE Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Rasmus Kreipke
- Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, and Department of Clinical Research, Faculty of Health Sciences, University of Southern Denmark, Odense, Denmark
| | - Cecilia Rogmark
- Department of Orthopaedics, Skåne University Hospital, Lund University, Malmö, Sweden.,Swedish Hip Arthroplasty Register, Gothenburg, Sweden
| | - Alma B Pedersen
- Department of Clinical Epidemiology, Aarhus University Hospital, Aarhus, Denmark.,Danish Hip Arthroplasty Register, Aarhus, Denmark
| | - Johan Kärrholm
- Swedish Hip Arthroplasty Register, Gothenburg, Sweden.,Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Geir Hallan
- Norwegian Arthroplasty Register and Department of Orthopaedic Surgery, Haukeland University Hospital, Bergen, Norway
| | - Leif Ivar Havelin
- Department of Clinical Medicine, University of Bergen, Bergen, Norway
| | - Keijo Mäkelä
- Department of Orthopedics and Traumatology, Turku University Hospital, Turku, Finland
| | - Søren Overgaard
- Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, and Department of Clinical Research, Faculty of Health Sciences, University of Southern Denmark, Odense, Denmark.,Danish Hip Arthroplasty Register, Aarhus, Denmark
| |
Collapse
|
46
|
Biomechanics and Biotribology of UHMWPE Artificial Hip Joints. SPRINGER SERIES IN BIOMATERIALS SCIENCE AND ENGINEERING 2019. [DOI: 10.1007/978-981-13-6924-7_8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
|
47
|
Levin JM, Sultan AA, O'Donnell JA, Sodhi N, Khlopas A, Piuzzi NS, Mont MA. Modern Dual-Mobility Cups in Revision Total Hip Arthroplasty: A Systematic Review and Meta-Analysis. J Arthroplasty 2018; 33:3793-3800. [PMID: 30195654 DOI: 10.1016/j.arth.2018.08.013] [Citation(s) in RCA: 44] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2018] [Revised: 07/23/2018] [Accepted: 08/08/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The purpose of this systematic review is to analyze the outcomes of dual-mobility (DM) cups in revision total hip arthroplasty (THA). Specifically, we evaluated the following: (1) all-cause and aseptic survivorship rates; (2) dislocation rates; (3) complications; and (4) clinical outcomes reported using validated health status measures. METHODS A comprehensive literature search included studies that reported the following: (1) re-revision rates, (2) complications, and (3) clinical outcomes following DM use in revision THA. The following exclusion criteria were used: (1) studies that did not stratify their analysis between primary and revision THA, (2) studies that utilized off-label techniques, (3) review articles, (4) case studies, (5) basic science articles, (6) non-English language reports, and (6) reports on patients who underwent surgery before 2010, in order to reflect modern DM implants use and technology. A total of 9 studies were included in our final analysis. RESULTS Aseptic and all-cause survivorship rates were 97.7% and 94.5%. Prevalence of dislocation was 2.2%, and 0.3% for intraprosthetic dislocation. Meta-analysis comparing DM to fixed-bearing prostheses demonstrated a significantly lower odds of dislocation in the DM cohort (odds ratio 0.24, P = .002). Complications occurred in 7.4% of revision THAs with DM cups, while infection rates totaled to 3.3% of cases. Studies comparing outcomes using Harris Hip Scores did not demonstrate a statistically significant difference in improved postoperative scores (P > .05). CONCLUSION DM cups have demonstrated excellent survivorship, low dislocation, and overall complication rates. Therefore, it can be considered a safe and effective option, particularly in the high-risk patients who undergo revision THA.
Collapse
Affiliation(s)
- Jay M Levin
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, OH
| | - Assem A Sultan
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, OH
| | | | - Nipun Sodhi
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, OH
| | - Anton Khlopas
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, OH
| | - Nicolas S Piuzzi
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, OH
| | - Michael A Mont
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, OH; Department of Orthopaedic Surgery, Lenox Hill Hospital, New York, NY
| |
Collapse
|
48
|
Neri T, Philippot R, Klasan A, Putnis S, Leie M, Boyer B, Farizon F. Dual mobility acetabular cups for total hip arthroplasty: advantages and drawbacks. Expert Rev Med Devices 2018; 15:835-845. [PMID: 30345834 DOI: 10.1080/17434440.2018.1538781] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
INTRODUCTION The dual mobility cup (DMC) concept was proposed by Professor Gilles Bousquet in 1974. Its' aims were to prevent postoperative dislocation, restore the physiological range of motion of the hip, and reduce the stresses at the interface. Since it was created, this design has been modified multiple times to reduce the complication rate, improve implant survival, and expand the indications. AREAS COVERED The objective of this review is to discuss the advantages and disadvantages of this implant based on its 40-year history and also to propose a range of indications based on published results. This will provide surgeons with a complete overview of DMC. EXPERT COMMENTARY Published studies on DMC confirm the low dislocation rate. Improvements made to DMC overtime have greatly reduced the complications related to wear, such as aseptic loosening and intraprosthetic dislocation (IPD). According to the literature, the indications have expanded and are no longer limited to revision surgery only. Long-term studies are needed before we can draw formal conclusions and consolidate these promising results.
Collapse
Affiliation(s)
- Thomas Neri
- a Department of Orthopaedic Surgery , University Hospital Centre of Saint-Etienne , Saint Etienne , France.,b EA 7424, Inter-university Laboratory of Human Movement Science , University Lyon, University Jean Monnet , Saint Etienne , France.,c Sydney Orthopaedic Research Institute , Sydney , Australia
| | - Remi Philippot
- a Department of Orthopaedic Surgery , University Hospital Centre of Saint-Etienne , Saint Etienne , France.,b EA 7424, Inter-university Laboratory of Human Movement Science , University Lyon, University Jean Monnet , Saint Etienne , France
| | - Antonio Klasan
- c Sydney Orthopaedic Research Institute , Sydney , Australia
| | - Sven Putnis
- c Sydney Orthopaedic Research Institute , Sydney , Australia
| | - Murilo Leie
- c Sydney Orthopaedic Research Institute , Sydney , Australia
| | - Bertrand Boyer
- a Department of Orthopaedic Surgery , University Hospital Centre of Saint-Etienne , Saint Etienne , France.,b EA 7424, Inter-university Laboratory of Human Movement Science , University Lyon, University Jean Monnet , Saint Etienne , France
| | - Frederic Farizon
- a Department of Orthopaedic Surgery , University Hospital Centre of Saint-Etienne , Saint Etienne , France.,b EA 7424, Inter-university Laboratory of Human Movement Science , University Lyon, University Jean Monnet , Saint Etienne , France
| |
Collapse
|
49
|
Faldini C, Stefanini N, Fenga D, Neonakis EM, Perna F, Mazzotti A, Pilla F, Triantafyllopoulos IK, Traina F. How to prevent dislocation after revision total hip arthroplasty: a systematic review of the risk factors and a focus on treatment options. J Orthop Traumatol 2018; 19:17. [PMID: 30203338 PMCID: PMC6131116 DOI: 10.1186/s10195-018-0510-2] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/26/2017] [Accepted: 07/19/2018] [Indexed: 02/08/2023] Open
Abstract
Background Dislocation represents the most common complication after revision total hip arthroplasty (rTHA). Understanding risk factors for dislocation has a great clinical relevance for every hip surgeon in order to consider all surgical options for effective planning. The aim of this systematic review was to answer two main questions—(1) what are the risk factors for instability after rTHA? and (2) what are the best preoperative assessments and surgical options to avoid dislocation after rTHA? Materials and methods Scientific databases were accessed to identify papers dealing with prevention and treatment of dislocation after rTHA. We performed a search using the keywords ‘revision hip arthroplasty’ and ‘dislocation’, ‘instability’, ‘outcome’, ‘failure’, ‘treatment’. After removal of duplicates and exclusion of works published in different languages, 33 articles were reviewed completely. Results Risk factors were analysed in order to establish the most relevant and evidence-based treatments available in the current literature. Conclusions The risk of dislocation after rTHA can be reduced using some precautions inferred from the literature. The use of a larger femoral and acetabular component, elevated rim liner and dual mobility implants can significantly reduce the risk of dislocation after rTHA. However, care must be taken regarding patient-related risk factors since these cannot be addressed and modified. Hence, a complete evaluation of risk factors should be performed for each patient and procedure before starting rTHA.
Collapse
Affiliation(s)
- C Faldini
- 1st Orthopaedic and Traumatologic Clinic, IRCCS Istituto Ortopedico Rizzoli, Via Giulio Cesare Pupilli 1, 40136, Bologna, Italy.
| | - N Stefanini
- 1st Orthopaedic and Traumatologic Clinic, IRCCS Istituto Ortopedico Rizzoli, Via Giulio Cesare Pupilli 1, 40136, Bologna, Italy
| | - D Fenga
- Department of Biomedical and Dental Sciences and Morphofunctional Imaging, University Hospital "G.Martino", Messina, Italy
| | - E M Neonakis
- Agia Sofia General Children's Hospital, Athens, Greece
| | - F Perna
- 1st Orthopaedic and Traumatologic Clinic, IRCCS Istituto Ortopedico Rizzoli, Via Giulio Cesare Pupilli 1, 40136, Bologna, Italy
| | - A Mazzotti
- 1st Orthopaedic and Traumatologic Clinic, IRCCS Istituto Ortopedico Rizzoli, Via Giulio Cesare Pupilli 1, 40136, Bologna, Italy
| | - F Pilla
- 1st Orthopaedic and Traumatologic Clinic, IRCCS Istituto Ortopedico Rizzoli, Via Giulio Cesare Pupilli 1, 40136, Bologna, Italy
| | | | - F Traina
- Department of Biomedical and Dental Sciences and Morphofunctional Imaging, University Hospital "G.Martino", Messina, Italy
| |
Collapse
|
50
|
Ozden VE, Dikmen G, Beksac B, Tozun R. Dual-mobility bearings for patients with abductor-trochanteric complex insufficiency. Hip Int 2018; 28:491-497. [PMID: 29781290 DOI: 10.1177/1120700018757788] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION The purpose of this study was to summarise the performance of dual-mobility cup systems for revision total hip arthroplasty in patients with abductor-trochanteric complex deficiency. METHODS We prospectively followed 17 patients (20 hips) with a mean age of 64.5 years (range 33-89 years) who underwent acetabular reconstruction with dual-mobility cups for aseptic loosening in 12 hips, infection treatment as second or single stage in 6 hips, and instability in 2 hips. All of the patients had abductor insufficiency. We evaluated the clinical Harris Hip scores (HHS) and radiographs for migration, loosening, and osteolysis. The survival of the components was calculated according to Kaplan-Meier survivorship analysis, and failure was defined as any dislocation, acetabular component or total hip revision for any reason. RESULTS The mean duration of follow-up was 38.1 months (range 24-98 months). There were 2 (12.5%) revisions for cemented cup migration after 11 months and 19 months respectively. There were no dislocations. At the last follow-up, the mean HHS increased from 42 points preoperatively to 86 points. The cumulative survival rate of the dual-mobility cup system was 93% (95% confidence interval 88-98.7%) at 5 years, with any revision as the end point. CONCLUSION Dual-mobility cups may provide excellent stability in patients with abductor-trochanteric complex insufficiency.
Collapse
Affiliation(s)
- Vahit E Ozden
- Department of Orthopaedic Surgery and Traumatology, Acibadem School of Medicine, Acibadem Maslak Hospital, Istanbul - Turkey
| | - Goksel Dikmen
- Department of Orthopaedic Surgery and Traumatology, Acibadem School of Medicine, Acibadem Maslak Hospital, Istanbul - Turkey
| | - Burak Beksac
- Department of Orthopaedic Surgery and Traumatology, Acibadem School of Medicine, Acibadem Maslak Hospital, Istanbul - Turkey
| | - Remzi Tozun
- Department of Orthopaedic Surgery and Traumatology, Acibadem School of Medicine, Acibadem Maslak Hospital, Istanbul - Turkey
| |
Collapse
|