1
|
ALCAN V, ZİNNUROĞLU M. Current developments in surface electromyography. Turk J Med Sci 2023; 53:1019-1031. [PMID: 38813041 PMCID: PMC10763750 DOI: 10.55730/1300-0144.5667] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Revised: 10/26/2023] [Accepted: 03/26/2023] [Indexed: 05/31/2024] Open
Abstract
Background/aim Surface electromyography (surface EMG) is a primary technique to detect the electrical activities of muscles through surface electrodes. In recent years, surface EMG applications have grown from conventional fields into new fields. However, there is a gap between the progress in the research of surface EMG and its clinical acceptance, characterized by the translational knowledge and skills in the widespread use of surface EMG among the clinician community. To reduce this gap, it is necessary to translate the updated surface EMG applications and technological advances into clinical research. Therefore, we aimed to present a perspective on recent developments in the application of surface EMG and signal processing methods. Materials and methods We conducted this scoping review following the Joanna Briggs Institute (JBI) method. We conducted a general search of PubMed and Web of Science to identify key search terms. Following the search, we uploaded selected articles into Rayyan and removed duplicates. After prescreening 133 titles and abstracts, we assessed 91 full texts according to the inclusion criteria. Results We concluded that surface EMG has made innovative technological progress and has research potential for routine clinical applications and a wide range of applications, such as neurophysiology, sports and art performances, biofeedback, physical therapy and rehabilitation, assessment of physical exercises, muscle strength, fatigue, posture and postural control, movement analysis, muscle coordination, motor synergies, modelling, and more. Novel methods have been applied for surface EMG signals in terms of time domain, frequency domain, time-frequency domain, statistical methods, and nonlinear methods. Conclusion Translating innovations in surface EMG and signal analysis methods into routine clinical applications can be a helpful tool with a growing and valuable role in muscle activation measurement in clinical practices. Thus, researchers must build many more interfaces that give opportunities for continuing education and research with more contemporary techniques and devices.
Collapse
Affiliation(s)
- Veysel ALCAN
- Department of Electrical and Electronics Engineering, Engineering Faculty, Tarsus University, Mersin,
Turkiye
| | - Murat ZİNNUROĞLU
- Department of Physical Medicine and Rehabilitation, Faculty of Medicine, Gazi University, Ankara,
Turkiye
| |
Collapse
|
2
|
Campanini I, Merlo A, Disselhorst-Klug C, Mesin L, Muceli S, Merletti R. Fundamental Concepts of Bipolar and High-Density Surface EMG Understanding and Teaching for Clinical, Occupational, and Sport Applications: Origin, Detection, and Main Errors. SENSORS (BASEL, SWITZERLAND) 2022; 22:4150. [PMID: 35684769 PMCID: PMC9185290 DOI: 10.3390/s22114150] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2022] [Revised: 05/20/2022] [Accepted: 05/26/2022] [Indexed: 06/15/2023]
Abstract
Surface electromyography (sEMG) has been the subject of thousands of scientific articles, but many barriers limit its clinical applications. Previous work has indicated that the lack of time, competence, training, and teaching is the main barrier to the clinical application of sEMG. This work follows up and presents a number of analogies, metaphors, and simulations using physical and mathematical models that provide tools for teaching sEMG detection by means of electrode pairs (1D signals) and electrode grids (2D and 3D signals). The basic mechanisms of sEMG generation are summarized and the features of the sensing system (electrode location, size, interelectrode distance, crosstalk, etc.) are illustrated (mostly by animations) with examples that teachers can use. The most common, as well as some potential, applications are illustrated in the areas of signal presentation, gait analysis, the optimal injection of botulinum toxin, neurorehabilitation, ergonomics, obstetrics, occupational medicine, and sport sciences. The work is primarily focused on correct sEMG detection and on crosstalk. Issues related to the clinical transfer of innovations are also discussed, as well as the need for training new clinical and/or technical operators in the field of sEMG.
Collapse
Affiliation(s)
- Isabella Campanini
- LAM-Motion Analysis Laboratory, Neuromotor and Rehabilitation Department, S. Sebastiano Hospital, Azienda USL-IRCCS di Reggio Emilia, Via Circondaria 29, 42015 Correggio, Italy; (I.C.); or (A.M.)
| | - Andrea Merlo
- LAM-Motion Analysis Laboratory, Neuromotor and Rehabilitation Department, S. Sebastiano Hospital, Azienda USL-IRCCS di Reggio Emilia, Via Circondaria 29, 42015 Correggio, Italy; (I.C.); or (A.M.)
- Merlo Bioengineering, 43121 Parma, Italy
| | - Catherine Disselhorst-Klug
- Department of Rehabilitation & Prevention Engineering, Institute of Applied Medical Engineering, RWTH Aachen University, Pauwelsstr. 20, 52074 Aachen, Germany;
| | - Luca Mesin
- Mathematical Biology and Physiology Group, Department of Electronics and Telecommunications, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Turin, Italy;
| | - Silvia Muceli
- Division of Signal Processing and Biomedical Engineering, Department of Electrical Engineering, Chalmers University of Technology, Hörsalsvägen 11, 41296 Gothenburg, Sweden;
| | - Roberto Merletti
- Laboratory for Engineering of the Neuromuscular System (LISiN), Department of Electronics and Telecommunications, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Turin, Italy
| |
Collapse
|
3
|
Luo X, Wang S, Rutkove SB, Sanchez B. Nonhomogeneous volume conduction effects affecting needle electromyography: an analytical and simulation study. Physiol Meas 2021; 42:10.1088/1361-6579/ac38c0. [PMID: 34763321 PMCID: PMC8744488 DOI: 10.1088/1361-6579/ac38c0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Accepted: 11/11/2021] [Indexed: 12/30/2022]
Abstract
Objective.Needle electromyography (EMG) is used to study the electrical behavior of myofiber properties in patients with neuromuscular disorders. However, due to the complexity of electrical potential spatial propagation in nonhomogeneous diseased muscle, a comprehensive understanding of volume conduction effects remains elusive. Here, we develop a framework to study the conduction effect of extracellular abnormalities and electrode positioning on extracellular local field potential (LFP) recordings.Methods.The framework describes the macroscopic conduction of electrical potential in an isotropic, nonhomogeneous (i.e. two tissue) model. Numerical and finite element model simulations are provided to study the conduction effect in prototypical monopolar EMG measurements.Results.LFPs recorded are influenced in amplitude, phase and duration by the electrode position in regards to the vicinity of tissue with different electrical properties.Conclusion.The framework reveals the influence of multiple mechanisms affecting LFPs including changes in the distance between the source-electrode and tissue electrical properties.Clinical significance.Our modeled predictions may lead to new ways for interpreting volume conduction effects on recorded EMG activity, for example in neuromuscular diseases that cause structural and compositional changes in muscle tissue. These change will manifest itself by changing the electric properties of the conductor media and will impact recorded potentials in the area of affected tissue.
Collapse
Affiliation(s)
- Xuesong Luo
- Department of Automation Science and Electric Engineering, Beijing Advanced Innovation Center for Big Data-Based Precision Medicine, Beihang University, Beijing 100083, China
- Sanchez Research Lab, Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT 84112-9206, USA
| | - Shaoping Wang
- Department of Automation Science and Electric Engineering, Beijing Advanced Innovation Center for Big Data-Based Precision Medicine, Beihang University, Beijing 100083, China
| | - Seward B. Rutkove
- Department of Neurology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA 02215, USA
| | - Benjamin Sanchez
- Sanchez Research Lab, Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT 84112-9206, USA
| |
Collapse
|
4
|
Ma S, Chen C, Zhao J, Han D, Sheng X, Farina D, Zhu X. Analytical Modelling of Surface EMG Signals Generated by Curvilinear Fibers with Approximate Conductivity Tensor. IEEE Trans Biomed Eng 2021; 69:1052-1062. [PMID: 34529557 DOI: 10.1109/tbme.2021.3112766] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
OBJECTIVE Mathematical modelling of surface electromyographic (EMG) signals has been proven a valuable tool to interpret experimental data and to validate signal processing techniques. Most analytical EMG models only consider muscle fibers with specific and fixed arrangements. However, the fiber orientation and curvature may change along the fiber paths and may differ from fiber to fiber. Here we propose a subject-specific EMG model that simulates the fiber trajectories in muscles of the upper arm and analytically derives the action potentials assuming an approximate conductivity tensor. METHODS Magnetic Resonance (MR) images were acquired to identify and generate muscle fiber paths and to determine the muscle locations in a cylindrical volume conductor. While the propagation of the action potentials followed the identified curvilinear fiber paths, the conductivity tensor was not adapted to the fiber direction but approximated along the longitudinal axis of the cylindrical volume conductor. Single fiber action potentials (SFAPs) were computed by simulating the generation, propagation, and extinction of membrane current sources. To validate the assumption of the approximate conductivity tensor, two numerical models were implemented for comparison with the analytical solution. The first numerical model reproduced the analytical model and therefore included an approximation for the conductivity tensor. The second numerical model included the exact conductivity tensor derived from the fiber curvatures. RESULTS The motor unit action potentials generated by the proposed analytical model and the two numerical models were highly similar (cross-correlation >0.98, normalized root mean square error, nRMSE 0.04, relative error in the median frequency of the simulated waveforms of approximately 3%). The proposed analytical model was also evaluated by comparing simulated and experimentally recorded compound muscle action potentials (CMAPs). The CMAPs simulated with the proposed model better matched the experimental data (cross-correlation >0.90 and nRMSE <0.25 for the majority of the channels) than a model with straight fibers. Finally, the proposed model was representatively used to test the accuracy of an EMG decomposition algorithm, providing a realistic benchmark. CONCLUSIONS AND SIGNIFICANCE The proposed analytical model generates action potentials that reflect the spatial distributions of muscle fibers with curvilinear paths. The simulated signals are more realistic than signals generated by analytical models with straight fibers and can therefore be applied for testing EMG processing algorithms with a trade-off between simulation accuracy and computational speed.
Collapse
|
5
|
Schlink BR, Ferris DP. A Lower Limb Phantom for Simulation and Assessment of Electromyography Technology. IEEE Trans Neural Syst Rehabil Eng 2019; 27:2378-2385. [DOI: 10.1109/tnsre.2019.2944297] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
6
|
Merletti R, Muceli S. Tutorial. Surface EMG detection in space and time: Best practices. J Electromyogr Kinesiol 2019; 49:102363. [PMID: 31665683 DOI: 10.1016/j.jelekin.2019.102363] [Citation(s) in RCA: 118] [Impact Index Per Article: 23.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2019] [Revised: 08/26/2019] [Accepted: 10/03/2019] [Indexed: 11/28/2022] Open
Abstract
This tutorial is aimed to non-engineers using, or planning to use, surface electromyography (sEMG) as an assessment tool in the prevention, monitoring and rehabilitation fields. Its first purpose is to address the issues related to the origin and nature of the signal and to its detection (electrode size, distance, location) by one-dimensional (bipolar and linear arrays) and two-dimensional (grids) electrode systems while avoiding advanced mathematical, physical or physiological issues. Its second purpose is to outline best practices and provide general guidelines for proper signal detection. Issues related to the electrode-skin interface, signal conditioning and interpretation will be discussed in subsequent tutorials.
Collapse
Affiliation(s)
- R Merletti
- LISiN, Dept. of Electronics and Telecommunications, Politecnico di Torino, Italy.
| | - S Muceli
- Division of Signal Processing and Biomedical Engineering, Department of Electrical Engineering, Chalmers University of Technology, Gothenburg, Sweden; Imperial College, London, UK.
| |
Collapse
|
7
|
Cai S, Chen Y, Huang S, Wu Y, Zheng H, Li X, Xie L. SVM-Based Classification of sEMG Signals for Upper-Limb Self-Rehabilitation Training. Front Neurorobot 2019; 13:31. [PMID: 31214010 PMCID: PMC6558101 DOI: 10.3389/fnbot.2019.00031] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2019] [Accepted: 05/09/2019] [Indexed: 11/28/2022] Open
Abstract
Robot-assisted rehabilitation is a growing field that can provide an intensity, quality, and quantity of treatment that exceed therapist-mediated rehabilitation. Several control algorithms have been implemented in rehabilitation robots to develop a patient-cooperative strategy with the capacity to understand the intention of the user and provide suitable rehabilitation training. In this paper, we present an upper-limb motion pattern recognition method using surface electromyography (sEMG) signals with a support vector machine (SVM) to control a rehabilitation robot, ReRobot, which was built to conduct upper-limb rehabilitation training for post-stroke patients. For poststroke rehabilitation training using the ReRobot, the upper-limb motion of the patient's healthy side is first recognized by detecting and processing the sEMG signals; then, the ReRobot assists the impaired arm in conducting mirror rehabilitation therapy. To train and test the SVM model, five healthy subjects participated in the experiments and performed five standard upper-limb motions, including shoulder flexion, abduction, internal rotation, external rotation, and elbow joint flexion. Good accuracy was demonstrated in experimental results from the five healthy subjects. By recognizing the model motion of the healthy side, the rehabilitation robot can provide mirror therapy to the affected side. This method can be used as a control strategy of upper-limb rehabilitation robots for self-rehabilitation training with stroke patients.
Collapse
Affiliation(s)
- Siqi Cai
- Shien-Ming Wu School of Intelligent Engineering, South China University of Technology, Guangzhou, China
| | - Yan Chen
- Shien-Ming Wu School of Intelligent Engineering, South China University of Technology, Guangzhou, China
| | - Shuangyuan Huang
- Shien-Ming Wu School of Intelligent Engineering, South China University of Technology, Guangzhou, China
| | - Yan Wu
- ASTAR Institute for Infocomm Research, Singapore, Singapore
| | - Haiqing Zheng
- The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Xin Li
- The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Longhan Xie
- Shien-Ming Wu School of Intelligent Engineering, South China University of Technology, Guangzhou, China
| |
Collapse
|
8
|
Independent component analysis based algorithms for high-density electromyogram decomposition: Systematic evaluation through simulation. Comput Biol Med 2019; 109:171-181. [DOI: 10.1016/j.compbiomed.2019.04.033] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2018] [Revised: 04/22/2019] [Accepted: 04/25/2019] [Indexed: 11/22/2022]
|
9
|
Papagiannis GI, Triantafyllou AI, Roumpelakis IM, Zampeli F, Garyfallia Eleni P, Koulouvaris P, Papadopoulos EC, Papagelopoulos PJ, Babis GC. Methodology of surface electromyography in gait analysis: review of the literature. J Med Eng Technol 2019; 43:59-65. [PMID: 31074312 DOI: 10.1080/03091902.2019.1609610] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Gait analysis is a significant diagnostic procedure for the clinicians who manage musculoskeletal disorders. Surface electromyography (sEMG) combined with kinematic and kinetic data is a useful tool for decision making of the appropriate method needed to treat such patients. sEMG has been used for decades to evaluate neuromuscular responses during a range of activities and develop rehabilitation protocols. The sEMG methodology followed by researchers assessed the issues of noise control, wave frequency, cross talk, low signal reception, muscle co-contraction, electrode placement protocol and procedure as well as EMG signal timing, intensity and normalisation so as to collect accurate, adequate and meaningful data. Further research should be done to provide more information related to the muscle activity recorded by sEMG and the force produced by the corresponding muscle during gait analysis.
Collapse
Affiliation(s)
- Georgios I Papagiannis
- a 1st Department of Orthopaedic Surgery, Medical School , Orthopaedic Research and Education Center "P.N.Soukakos", Biomechanics and Gait Analysis Laboratory "Sylvia Ioannou", "Attikon" University Hospital, National and Kapodistrian University of Athens , Athens , Greece.,b Physioloft Physical Therapy Center , Athens , Greece
| | - Athanasios I Triantafyllou
- a 1st Department of Orthopaedic Surgery, Medical School , Orthopaedic Research and Education Center "P.N.Soukakos", Biomechanics and Gait Analysis Laboratory "Sylvia Ioannou", "Attikon" University Hospital, National and Kapodistrian University of Athens , Athens , Greece.,b Physioloft Physical Therapy Center , Athens , Greece
| | - Ilias M Roumpelakis
- a 1st Department of Orthopaedic Surgery, Medical School , Orthopaedic Research and Education Center "P.N.Soukakos", Biomechanics and Gait Analysis Laboratory "Sylvia Ioannou", "Attikon" University Hospital, National and Kapodistrian University of Athens , Athens , Greece.,b Physioloft Physical Therapy Center , Athens , Greece
| | - Frantzeska Zampeli
- a 1st Department of Orthopaedic Surgery, Medical School , Orthopaedic Research and Education Center "P.N.Soukakos", Biomechanics and Gait Analysis Laboratory "Sylvia Ioannou", "Attikon" University Hospital, National and Kapodistrian University of Athens , Athens , Greece
| | | | - Panayiotis Koulouvaris
- a 1st Department of Orthopaedic Surgery, Medical School , Orthopaedic Research and Education Center "P.N.Soukakos", Biomechanics and Gait Analysis Laboratory "Sylvia Ioannou", "Attikon" University Hospital, National and Kapodistrian University of Athens , Athens , Greece
| | - Elias C Papadopoulos
- c 2nd Department of Orthopaedic Surgery, Medical School , Konstantopouleio General Hospital, Nea Ionia, National and Kapodistrian University of Athens , Athens , Greece
| | - Panayiotis J Papagelopoulos
- a 1st Department of Orthopaedic Surgery, Medical School , Orthopaedic Research and Education Center "P.N.Soukakos", Biomechanics and Gait Analysis Laboratory "Sylvia Ioannou", "Attikon" University Hospital, National and Kapodistrian University of Athens , Athens , Greece
| | - George C Babis
- c 2nd Department of Orthopaedic Surgery, Medical School , Konstantopouleio General Hospital, Nea Ionia, National and Kapodistrian University of Athens , Athens , Greece
| |
Collapse
|
10
|
Ang WS, Geyer H, Chen IM, Ang WT. Objective Assessment of Spasticity With a Method Based on a Human Upper Limb Model. IEEE Trans Neural Syst Rehabil Eng 2018; 26:1414-1423. [DOI: 10.1109/tnsre.2018.2821197] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
11
|
Sex-specific reliability and multidimensional stability of responses to tests assessing neuromuscular function. HOMO-JOURNAL OF COMPARATIVE HUMAN BIOLOGY 2017; 68:452-464. [PMID: 29175061 DOI: 10.1016/j.jchb.2017.10.004] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/07/2016] [Accepted: 10/30/2017] [Indexed: 11/22/2022]
Abstract
The objective of this study was to estimate sex-specific effects in the test-retest cross-reliability of peripheral and central changes in nonlinear and linear measures of a surface electromyography signal during a brief (5 second) and sustained (2minute) isometric maximal voluntary contraction, combined with superimposed electrical stimulation involving the ankle plantar flexors over five identical trials. In this study, we repeated the testing protocol used in our previous study of 10 women (age 20.9, SD=0.3 years) (Bernecke et al., 2015) in a group of 10 men (age 21.2, SD=0.4 years). Despite the central (sex effect; p<0.05, ηp2>0.71, SP>70%) and peripheral fatigability (sex effect; p<0.01, ηp2>0.8, SP>90%) during sustained isometric maximal voluntary contraction, and lower reliability for central activation ratio during brief (intraclass correlation coefficient [ICC]=0.95 for men and ICC=0.82 for women) and sustained maximal voluntary contraction (ICC>0.82 for men and ICC>0.66 for women) over ankle plantar flexors expressed in women more than in men, all the ICCs of all indices measured by tests assessing neuromuscular function across the five identical test-retest trials were found as meaningful (correlation significance of p<0.05 was reached) and no significant differences were found between trials for any of the measured variables. In conclusion, the present study demonstrated greater central and peripheral fatigue for female participants following sustained (2minute) isometric maximal voluntary contraction of the plantar flexor muscles for all repeated trials and indicated an acceptable agreement between measurements of the characteristic variables made using the three different devices (dynamometry, electrical stimulation, and surface electromyography) over time for both sexes.
Collapse
|
12
|
Wearable bio signal monitoring system applied to aviation safety. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2017; 2017:2349-2352. [PMID: 29060369 DOI: 10.1109/embc.2017.8037327] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Pilots are required to have the ability to evaluate their own physical and psychological status to operate high performance aircrafts effectively. Existing studies have lacked consideration of applying bio signal of pilots in real time flight situation. The purpose of this study is to develop a wearable bio signal monitoring system that can measure the condition of pilots under an extreme flight environment to ensure flight safety. The wearable bio signal monitoring system consists of an algorithm for evaluating pilots' physiological stability, algorithms for detecting Gravity-induced Loss of Consciousness (G-LOC) prognosis, pilots' interaction module, and pilots' context awareness platform. The algorithm for evaluating pilots' physiological stability uses psychomotor cognitive test (PCT) and heart rate variability (HRV) to measure pilots' mission performance before flight. The algorithms for detecting G-LOC prognosis utilizes electromyogram (EMG) to generate warning signal during flight. The pilots' interaction module was developed for pilots to operate the system efficiently under flight environment. The pilots' context awareness platform was designed for the system to process multiple sensor signals in real time. This wearable bio signal monitoring system is expected to enhance flight safety and mission performance of pilots.
Collapse
|
13
|
Marco G, Alberto B, Taian V. Surface EMG and muscle fatigue: multi-channel approaches to the study of myoelectric manifestations of muscle fatigue. Physiol Meas 2017; 38:R27-R60. [DOI: 10.1088/1361-6579/aa60b9] [Citation(s) in RCA: 44] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
14
|
Ning Y, Zhang Y. A new approach for multi-channel surface EMG signal simulation. Biomed Eng Lett 2017; 7:45-53. [PMID: 30603150 DOI: 10.1007/s13534-017-0009-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2016] [Revised: 11/29/2016] [Accepted: 12/01/2016] [Indexed: 11/29/2022] Open
Abstract
Simulation models are necessary for testing the performance of newly developed approaches before they can be applied to interpreting experimental data, especially when biomedical signals such as surface electromyogram (SEMG) signals are involved. A new and easily implementable surface EMG simulation model was developed in this study to simulate multi-channel SEMG signals. A single fiber action potential (SFAP) is represented by the sum of three Gaussian functions. SFAP waveforms can be modified by adjusting the amplitude and bandwidth of the Gaussian functions. SEMG signals were successfully simulated at different detected locations. Effects of the fiber depth, electrode position and conduction velocity of SFAP on motor unit action potential (MUAP) were illustrated. Results demonstrate that the easily implementable SEMG simulation approach developed in this study can be used to effectively simulate SEMG signals.
Collapse
Affiliation(s)
- Yong Ning
- 1School of Automation and Electrical Engineering, Zhejiang University of Science and Technology, Hangzhou, 310023 Zhejiang China
| | - Yingchun Zhang
- Guangdong Provincial Work Injury Rehabilitation Center, Guangzhou, 510000 China.,3Department of Biomedical Engineering, Cullen College of Engineering, University of Houston, 3605 Cullen Blvd, Room 2024, Houston, TX 77204 USA
| |
Collapse
|
15
|
Age-Associated Changes in the Spectral and Statistical Parameters of Surface Electromyogram of Tibialis Anterior. BIOMED RESEARCH INTERNATIONAL 2016; 2016:7159701. [PMID: 27610379 PMCID: PMC5005778 DOI: 10.1155/2016/7159701] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/26/2016] [Revised: 07/15/2016] [Accepted: 07/19/2016] [Indexed: 01/10/2023]
Abstract
Age-related neuromuscular change of Tibialis Anterior (TA) is a leading cause of muscle strength decline among the elderly. This study has established the baseline for age-associated changes in sEMG of TA at different levels of voluntary contraction. We have investigated the use of Gaussianity and maximal power of the power spectral density (PSD) as suitable features to identify age-associated changes in the surface electromyogram (sEMG). Eighteen younger (20–30 years) and 18 older (60–85 years) cohorts completed two trials of isometric dorsiflexion at four different force levels between 10% and 50% of the maximal voluntary contraction. Gaussianity and maximal power of the PSD of sEMG were determined. Results show a significant increase in sEMG's maximal power of the PSD and Gaussianity with increase in force for both cohorts. It was also observed that older cohorts had higher maximal power of the PSD and lower Gaussianity. These age-related differences observed in the PSD and Gaussianity could be due to motor unit remodelling. This can be useful for noninvasive tracking of age-associated neuromuscular changes.
Collapse
|
16
|
Siddiqi A, Arjunan SP, Kumar DK. Age related neuromuscular changes in sEMG of m. Tibialis Anterior using higher order statistics (Gaussianity & linearity test). ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2016:3638-3641. [PMID: 28324992 DOI: 10.1109/embc.2016.7591516] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Age-associated changes in the surface electromyogram (sEMG) of Tibialis Anterior (TA) muscle can be attributable to neuromuscular alterations that precede strength loss. We have used our sEMG model of the Tibialis Anterior to interpret the age-related changes and compared with the experimental sEMG. Eighteen young (20-30 years) and 18 older (60-85 years) performed isometric dorsiflexion at 6 different percentage levels of maximum voluntary contractions (MVC), and their sEMG from the TA muscle was recorded. Six different age-related changes in the neuromuscular system were simulated using the sEMG model at the same MVCs as the experiment. The maximal power of the spectrum, Gaussianity and Linearity Test Statistics were computed from the simulated and experimental sEMG. A correlation analysis at α=0.05 was performed between the simulated and experimental age-related change in the sEMG features. The results show the loss in motor units was distinguished by the Gaussianity and Linearity test statistics; while the maximal power of the PSD distinguished between the muscular factors. The simulated condition of 40% loss of motor units with halved the number of fast fibers best correlated with the age-related change observed in the experimental sEMG higher order statistical features. The simulated aging condition found by this study corresponds with the moderate motor unit remodelling and negligible strength loss reported in literature for the cohorts aged 60-70 years.
Collapse
|
17
|
A Finite Element Model Approach to Determine the Influence of Electrode Design and Muscle Architecture on Myoelectric Signal Properties. PLoS One 2016; 11:e0148275. [PMID: 26886908 PMCID: PMC4757537 DOI: 10.1371/journal.pone.0148275] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2015] [Accepted: 01/15/2016] [Indexed: 11/20/2022] Open
Abstract
Introduction Surface electromyography (sEMG) is the measurement of the electrical activity of the skeletal muscle tissue detected at the skin’s surface. Typically, a bipolar electrode configuration is used. Most muscles have pennate and/or curved fibres, meaning it is not always feasible to align the bipolar electrodes along the fibres direction. Hence, there is a need to explore how different electrode designs can affect sEMG measurements. Method A three layer finite element (skin, fat, muscle) muscle model was used to explore different electrode designs. The implemented model used as source signal an experimentally recorded intramuscular EMG taken from the biceps brachii muscle of one healthy male. A wavelet based intensity analysis of the simulated sEMG signal was performed to analyze the power of the signal in the time and frequency domain. Results The model showed muscle tissue causing a bandwidth reduction (to 20-92- Hz). The inter-electrode distance (IED) and the electrode orientation relative to the fibres affected the total power but not the frequency filtering response. The effect of significant misalignment between the electrodes and the fibres (60°- 90°) could be reduced by increasing the IED (25–30 mm), which attenuates signal cancellation. When modelling pennated fibres, the muscle tissue started to act as a low pass filter. The effect of different IED seems to be enhanced in the pennated model, while the filtering response is changed considerably only when the electrodes are close to the signal termination within the model. For pennation angle greater than 20°, more than 50% of the source signal was attenuated, which can be compensated by increasing the IED to 25 mm. Conclusion Differences in tissue filtering properties, shown in our model, indicates that different electrode designs should be considered for muscle with different geometric properties (i.e. pennated muscles).
Collapse
|
18
|
Detection of G-Induced Loss of Consciousness (G-LOC) prognosis through EMG monitoring on gastrocnemius muscle in flight. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2015:7007-10. [PMID: 26737905 DOI: 10.1109/embc.2015.7320005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
G-Induced Loss of Consciousness (G-LOC) is mainly caused by the sudden acceleration in the direction of +Gz axis from the fighter pilots, and is considered as an emergent situation of which fighter pilots are constantly aware. In order to resist against G-LOC, fighter pilots are subject to run Anti-G straining maneuver (AGSM), which includes L-1 respiration maneuvering and muscular contraction of the whole body. The purpose of this study is to create a G-LOC warning alarm prior to G-LOC by monitoring the Electromyogram (EMG) of the gastrocnemius muscle on the calf, which goes under constant muscular contraction during the AGSM process. EMG data was retrieved from pilots and pilot trainees of the Korean Air Force, during when subjects were under high G-trainings on a human centrifugal simulator. Out of the EMG features, integrated absolute value (IAV), reflecting muscle contraction, and waveform length (WL), reflecting muscle contraction and fatigue, have shown a rapid decay during the alarm phase, 3 seconds before G-LOC, compared to that of a normal phase withstanding G-force. Such results showed consistency amongst pilots and pilot trainees who were under G-LOC. Based on these findings, this study developed an algorithm which can detect G-LOC prognosis during flight, and at the same time, generate warning signals. The probability of G-LOC occurrence is detected through monitoring the decay trend and degree of the IVA and WL value of when the pilot initiates AGSM during sudden acceleration above 6G. Conclusively, this G-LOC prognosis detecting and warning system is a customized, real-time countermeasure which enhanced the accuracy of detecting G-LOC.
Collapse
|
19
|
Vieira TM, Botter A, Minetto MA, Hodson-Tole EF. Spatial variation of compound muscle action potentials across human gastrocnemius medialis. J Neurophysiol 2015; 114:1617-27. [PMID: 26156382 DOI: 10.1152/jn.00221.2015] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2015] [Accepted: 06/26/2015] [Indexed: 12/14/2022] Open
Abstract
The massed action potential (M wave) elicited through nerve stimulation underpins a wide range of physiological and mechanical understanding of skeletal muscle structure and function. Although systematic approaches have evaluated the effect of different factors on M waves, the effect of the location and distribution of activated fibers within the muscle remains unknown. By detecting M waves from the medial gastrocnemius (MG) of 12 participants with a grid of 128 electrodes, we investigated whether different populations of muscle units have different spatial organization within MG. If populations of muscle units occupy discrete MG regions, current pulses of progressively greater intensities applied to the MG nerve branch would be expected to lead to local changes in M-wave amplitudes. Electrical pulses were therefore delivered at 2 pps, with the current pulse amplitude increased every 10 stimuli to elicit different degrees of muscle activation. The localization of MG response to increases in current intensity was determined from the spatial distribution of M-wave amplitude. Key results revealed that increases in M-wave amplitude were detected somewhat locally, by 10-50% of the 128 electrodes. Most importantly, the electrodes detecting greatest increases in M-wave amplitude were localized at different regions in the grid, with a tendency for greater stimulation intensities to elicit M waves in the more distal MG region. The presented results indicate that M waves recorded locally may not provide a representative MG response, with major implications for the estimation of, e.g., the maximal stimulation levels, the number of motor units, and the onset and normalization in H-reflex studies.
Collapse
Affiliation(s)
- Taian M Vieira
- Laboratorio di Ingegneria del Sistema Neuromuscolare, Dipartimento di Elettronica e Telecomunicazioni, Politecnico di Torino, Turin, Italy; Escola de Educação Física e Desportos, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil
| | - Alberto Botter
- Laboratorio di Ingegneria del Sistema Neuromuscolare, Dipartimento di Elettronica e Telecomunicazioni, Politecnico di Torino, Turin, Italy;
| | - Marco A Minetto
- Division of Endocrinology, Diabetology and Metabolism, Department of Medical Sciences, University of Turin, Turin, Italy; Division of Physical Medicine and Rehabilitation, Department of Surgical Sciences, University of Turin, Turin, Italy; and
| | - Emma F Hodson-Tole
- School of Healthcare Sciences, Manchester Metropolitan University, Manchester, United Kingdom
| |
Collapse
|
20
|
Cronin NJ, Kumpulainen S, Joutjärvi T, Finni T, Piitulainen H. Spatial variability of muscle activity during human walking: the effects of different EMG normalization approaches. Neuroscience 2015; 300:19-28. [PMID: 25967267 DOI: 10.1016/j.neuroscience.2015.05.003] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2014] [Revised: 04/30/2015] [Accepted: 05/01/2015] [Indexed: 11/16/2022]
Abstract
Human leg muscles are often activated inhomogeneously, e.g. in standing. This may also occur in complex tasks like walking. Thus, bipolar surface electromyography (sEMG) may not accurately represent whole muscle activity. This study used 64-electrode high-density sEMG (HD-sEMG) to examine spatial variability of lateral gastrocnemius (LG) muscle activity during the stance phase of walking, maximal voluntary contractions (MVCs) and maximal M-waves, and determined the effects of different normalization approaches on spatial and inter-participant variability. Plantar flexion MVC, maximal electrically elicited M-waves and walking at self-selected speed were recorded in eight healthy males aged 24-34. sEMG signals were assessed in four ways: unnormalized, and normalized to MVC, M-wave or peak sEMG during the stance phase of walking. During walking, LG activity varied spatially, and was largest in the distal and lateral regions. Spatial variability fluctuated throughout the stance phase. Normalizing walking EMG signals to the peak value during stance reduced spatial variability within LG on average by 70%, and inter-participant variability by 67%. Normalizing to MVC reduced spatial variability by 17% but increased inter-participant variability by 230%. Normalizing to M-wave produced the greatest spatial variability (45% greater than unnormalized EMG) and increased inter-participant variability by 70%. Unnormalized bipolar LG sEMG may provide misleading results about representative muscle activity in walking due to spatial variability. For the peak value and MVC approaches, different electrode locations likely have minor effects on normalized results, whereas electrode location should be carefully considered when normalizing walking sEMG data to maximal M-waves.
Collapse
Affiliation(s)
- N J Cronin
- Neuromuscular Research Centre, Department of Biology of Physical Activity, University of Jyväskylä, P.O. Box 35, 40014 Jyväskylä, Finland.
| | - S Kumpulainen
- Neuromuscular Research Centre, Department of Biology of Physical Activity, University of Jyväskylä, P.O. Box 35, 40014 Jyväskylä, Finland
| | - T Joutjärvi
- Neuromuscular Research Centre, Department of Biology of Physical Activity, University of Jyväskylä, P.O. Box 35, 40014 Jyväskylä, Finland
| | - T Finni
- Neuromuscular Research Centre, Department of Biology of Physical Activity, University of Jyväskylä, P.O. Box 35, 40014 Jyväskylä, Finland
| | - H Piitulainen
- Brain Research Unit, O.V. Lounasmaa Laboratory, Aalto University School of Science, P.O. Box 15100, 00076 AALTO, Espoo, Finland
| |
Collapse
|
21
|
Mohseni Bandpei MA, Rahmani N, Majdoleslam B, Abdollahi I, Ali SS, Ahmad A. Reliability of Surface Electromyography in the Assessment of Paraspinal Muscle Fatigue: An Updated Systematic Review. J Manipulative Physiol Ther 2014; 37:510-21. [DOI: 10.1016/j.jmpt.2014.05.006] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2013] [Revised: 04/28/2014] [Accepted: 05/01/2014] [Indexed: 12/18/2022]
|
22
|
Siddiqi A, Kumar D, Arjunan SP. A model for generating Surface EMG signal of m. Tibialis Anterior. 2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY 2014; 2014:106-9. [PMID: 25569908 DOI: 10.1109/embc.2014.6943540] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
23
|
Wang J, Zhang Y, Zhu X, Zhou P, Liu C, Rymer WZ. A novel spatiotemporal muscle activity imaging approach based on the Extended Kalman Filter. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2013; 2012:6236-8. [PMID: 23367354 DOI: 10.1109/embc.2012.6347419] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
A novel spatiotemporal muscle activity imaging (sMAI) approach has been developed using the Extended Kalman Filter (EKF) to reconstruct internal muscle activities from non-invasive multi-channel surface electromyogram (sEMG) recordings. A distributed bioelectric dipole source model is employed to describe the internal muscle activity space, and a linear relationship between the muscle activity space and the sEMG measurement space is then established. The EKF is employed to recursively solve the ill-posed inverse problem in the sMAI approach, in which the weighted minimum norm (WMN) method is utilized to calculate the initial state and a new nonlinear method is developed based on the propagating features of muscle activities to predict the recursive state. A series of computer simulations was conducted to test the performance of the proposed sMAI approach. Results show that the localization error rapidly decreases over 35% and the overlap ratio rapidly increases over 45% compared to the results achieved using the WMN method only. The present promising results demonstrate the feasibility of utilizing the proposed EKF-based sMAI approach to accurately reconstruct internal muscle activities from non-invasive sEMG recordings.
Collapse
Affiliation(s)
- Jing Wang
- Department of Urology, University of Minnesota, Minneapolis, MN 55455, USA
| | | | | | | | | | | |
Collapse
|
24
|
Gallina A, Ritzel CH, Merletti R, Vieira TMM. Do surface electromyograms provide physiological estimates of conduction velocity from the medial gastrocnemius muscle? J Electromyogr Kinesiol 2012; 23:319-25. [PMID: 23265664 DOI: 10.1016/j.jelekin.2012.11.007] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2012] [Revised: 11/09/2012] [Accepted: 11/11/2012] [Indexed: 11/18/2022] Open
Abstract
Muscle fiber conduction velocity (CV) is commonly estimated from surface electromyograms (EMGs) collected with electrodes parallel to muscle fibers. If electrodes and muscle fibers are not located in parallel planes, CV estimates are biased towards values far over the physiological range. In virtue of their pinnate architecture, the fibers of muscles such as the gastrocnemius are hardly aligned in planes parallel to surface electrodes. Therefore, in this study we investigate whether physiological CV estimates can be obtained from the gastrocnemius muscle. Specifically, with a large grid of 16×8 electrodes we map CV estimates over the whole gastrocnemius muscle while eleven subjects exerted isometric plantar flexions at three different force levels. CV was estimated for couples of single differential EMGs and estimate locations (i.e., channels) were classified as physiological and non-physiological, depending on whether CV estimates were within the physiological range (3-6ms(-1)) or not. Physiological CV values could be estimated from a markedly small muscle region for eight participants; channels providing physiological CV estimates corresponded to about 5% of the total number of channels. As expected, physiological and non-physiological channels were clustered in distinct regions. CV estimates within the physiological range were obtained for the most distal gastrocnemius portion (ANOVA, P<0.001), where occurrences of propagating potentials were often verified through visual analysis. For the first time, this study shows that CV might be reliably assessed from surface EMGs collected from the most distal gastrocnemius region.
Collapse
Affiliation(s)
- Alessio Gallina
- Laboratorio di Ingegneria del Sistema Neuromuscolare (LISiN), Politecnico di Torino, Italy
| | | | | | | |
Collapse
|
25
|
Zhao Y, Li D. A simulation study on the relation between muscle motor unit numbers and the non-Gaussianity/non-linearity levels of surface electromyography. SCIENCE CHINA. LIFE SCIENCES 2012; 55:958-67. [PMID: 23160827 DOI: 10.1007/s11427-012-4400-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2012] [Accepted: 10/16/2012] [Indexed: 10/27/2022]
Abstract
Recent research has demonstrated that surface electromyography (sEMG) signals have non-Gaussianity and non-linearity properties. It is known that more muscle motor units are recruited and firing rates (FRs) increase as exertion increases. A hypothesis was proposed that the Gaussianity test (S (g)) and linearity test (S (ℓ)) levels of sEMG signals are associated with the number of active motor units (nMUs) and the FR. The hypothesis has only been preliminarily discussed in experimental studies. We used a simulation sEMG model involving spatial (active MUs) and temporal (three FRs) information to test the hypothesis. Higher-order statistics (HOS) from the bi-frequency domain were used to perform S (g) and S (ℓ). Multivariate covariance analysis and a correlation test were employed to determine the nMUs-S (g) relationship and the nMUs-S (ℓ) relationship. Results showed that nMUs, the FR, and the interaction of nMUs and the FR all influenced the S (g) and S (ℓ) values. The nMUs negatively correlated to both the S (g) and S (ℓ) values. That is, at the three FRs, sEMG signals tended to a more Gaussian and linear distribution as exertion and nMUs increased. The study limited experiment factors to the sEMG non-Gaussianity and non-linearity levels. The study quantitatively described nMUs and the FR of muscle that are not directly available from experiments. Our finding has guiding significance for muscle capability assessment and prosthetic control.
Collapse
Affiliation(s)
- Yan Zhao
- College of Aerospace Science and Engineering, National University of Defense Technology, Changsha 410073, China.
| | | |
Collapse
|
26
|
Nazarpour K, Al-Timemy AH, Bugmann G, Jackson A. A note on the probability distribution function of the surface electromyogram signal. Brain Res Bull 2012; 90:88-91. [PMID: 23047056 PMCID: PMC3878385 DOI: 10.1016/j.brainresbull.2012.09.012] [Citation(s) in RCA: 66] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2012] [Revised: 09/17/2012] [Accepted: 09/18/2012] [Indexed: 11/16/2022]
Abstract
The probability density function (PDF) of the surface electromyogram (EMG) signals has been modelled with Gaussian and Laplacian distribution functions. However, a general consensus upon the PDF of the EMG signals is yet to be reached, because not only are there several biological factors that can influence this distribution function, but also different analysis techniques can lead to contradicting results. Here, we recorded the EMG signal at different isometric muscle contraction levels and characterised the probability distribution of the surface EMG signal with two statistical measures: bicoherence and kurtosis. Bicoherence analysis did not help to infer the PDF of measured EMG signals. In contrast, with kurtosis analysis we demonstrated that the EMG PDF at isometric, non-fatiguing, low contraction levels is super-Gaussian. Moreover, kurtosis analysis showed that as the contraction force increases the surface EMG PDF tends to a Gaussian distribution.
Collapse
|
27
|
Wheeler KA, Kumar DK, Shimada H, Arjunan SP, Kalra C. Surface EMG model of the bicep during aging: a preliminary study. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2012; 2011:7127-30. [PMID: 22255981 DOI: 10.1109/iembs.2011.6091801] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Reduction in the median frequency and the amplitude of surface electromyogram (sEMG) has been observed among older subjects compared with the younger cohort. These changes in sEMG have been associated with a reduction in the number of muscle fibers and a drop in the ratio of type II muscle fibers. However, the details of this association are not known. This paper has experimentally determined the difference between the magnitude and spectrum of sEMG of the younger and older cohorts, and estimated the changes to the muscle by populating a lifelike model with the experimental data. Experiments were conducted on subjects belonging to younger (20-28 years) and older (61-69) age groups. From the simulated results, it is shown that experimental sEMG signals are matched by the model representing the older cohort with a substantially reduced number of motor units compared to the younger people. In the model, the best match with experimental results was observed when the ratio of the bicep motor units between the older and the younger subjects was 0.5. The results also indicate a substantial reduction in the ratio of fast fibers, from 0.45 in the younger cohort to 0.11 in the older cohort.
Collapse
Affiliation(s)
- Katherine A Wheeler
- School of Electrical and Computer Engineering at RMIT University, Melbourne, Australia.
| | | | | | | | | |
Collapse
|
28
|
Bowden JL, McNulty PA. Mapping the motor point in the human tibialis anterior muscle. Clin Neurophysiol 2011; 123:386-92. [PMID: 21802984 DOI: 10.1016/j.clinph.2011.06.016] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2011] [Revised: 05/31/2011] [Accepted: 06/19/2011] [Indexed: 11/25/2022]
Abstract
OBJECTIVE Percutaneous electrical stimulation of the motor point permits selective activation of a muscle. However, the definition and number of motor points reported for a given muscle varies. Our goal was to address these problems. METHODS The area, location and number of motor points in human tibialis anterior were examined, using isometric dorsiflexion torque responses to electrical stimuli. Three methods were used: lowest electrical threshold, maximum muscle response, and approximate motor point. RESULTS A single motor point was identified in 39/40 subjects regardless of method. The area of the site of lowest electrical threshold was smaller (median, 35 mm(2)) than those using the maximum muscle response (144 mm(2)) and approximate motor point (132 mm(2)). There was substantial, but not significant, between-subject variation in motor point location. Fifty three percent of motor points would have been missed if located only by reference to anatomical landmarks. CONCLUSIONS These results suggested that the motor point's location cannot be determined a priori and that the identification method will affect both area and location. SIGNIFICANCE If it is important to maximally activate a single muscle in isolation, the motor point is best represented by the site producing a maximal but isolated muscle response at the lowest stimulation intensity.
Collapse
Affiliation(s)
- J L Bowden
- Neuroscience Research Australia, Sydney, Australia
| | | |
Collapse
|
29
|
Mesin L, Merletti R, Vieira TMM. Insights gained into the interpretation of surface electromyograms from the gastrocnemius muscles: A simulation study. J Biomech 2011; 44:1096-103. [PMID: 21334627 DOI: 10.1016/j.jbiomech.2011.01.031] [Citation(s) in RCA: 68] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2010] [Revised: 01/26/2011] [Accepted: 01/26/2011] [Indexed: 01/29/2023]
Abstract
Interpretation of surface electromyograms (EMG) is usually based on the assumption that the surface representation of action potentials does not change during their propagation. This assumption does not hold for muscles whose fibers are oblique to the skin. Consequently, the interpretation of surface EMGs recorded from pinnate muscles unlikely prompts from current knowledge. Here we present a complete analytical model that supports the interpretation of experimental EMGs detected from muscles with oblique architecture. EMGs were recorded from the medial gastrocnemius muscle during voluntary and electrically elicited contractions. Preliminary indications obtained from simulated and experimental signals concern the spatial localization of surface potentials and the myoelectric fatigue. Specifically, the spatial distribution of surface EMGs was localized about the fibers superficial extremity. Strikingly, this localization increased with the pinnation angle, both for the simulated EMGs and the recorded M-waves. Moreover, the average rectified value (ARV) and the mean frequency (MNF) of interference EMGs increased and decreased with simulated fatigue, respectively. The degree of variation in ARV and MNF did not depend on the pinnation angle simulated. Similar variations were observed for the experimental EMGs, although being less evident for a higher fiber inclination. These results are discussed on a physiological context, highlighting the relevance of the model proposed here for the interpretation of gastrocnemius EMGs and for conceiving future experiments on muscles with pinnate geometry.
Collapse
Affiliation(s)
- Luca Mesin
- Department of Electronics, Politecnico di Torino, Torino, Italy
| | | | | |
Collapse
|
30
|
Wheeler KA, Shimada H, Kumar DK, Arjunan SP. A sEMG model with experimentally based simulation parameters. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2010; 2010:4258-61. [PMID: 21096642 DOI: 10.1109/iembs.2010.5627175] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
A differential, time-invariant, surface electromyogram (sEMG) model has been implemented. While it is based on existing EMG models, the novelty of this implementation is that it assigns more accurate distributions of variables to create realistic motor unit (MU) characteristics. Variables such as muscle fibre conduction velocity, jitter (the change in the interpulse interval between subsequent action potential firings) and motor unit size have been considered to follow normal distributions about an experimentally obtained mean. In addition, motor unit firing frequencies have been considered to have non-linear and type based distributions that are in accordance with experimental results. Motor unit recruitment thresholds have been considered to be related to the MU type. The model has been used to simulate single channel differential sEMG signals from voluntary, isometric contractions of the biceps brachii muscle. The model has been experimentally verified by conducting experiments on three subjects. Comparison between simulated signals and experimental recordings shows that the Root Mean Square (RMS) increases linearly with force in both cases. The simulated signals also show similar values and rates of change of RMS to the experimental signals.
Collapse
Affiliation(s)
- Katherine A Wheeler
- School of Electrical and Computer Engineering at RMIT University, Melbourne, Australia.
| | | | | | | |
Collapse
|
31
|
Piitulainen H, Botter A, Merletti R, Avela J. Muscle fiber conduction velocity is more affected after eccentric than concentric exercise. Eur J Appl Physiol 2010; 111:261-73. [PMID: 20865423 DOI: 10.1007/s00421-010-1652-y] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/08/2010] [Indexed: 11/30/2022]
Affiliation(s)
- Harri Piitulainen
- Department of Biology of Physical Activity, Neuromuscular Research Center, University of Jyväskylä, P.O. Box 35, 40014, Jyväskylä, Finland.
| | | | | | | |
Collapse
|
32
|
Navallas J, Malanda A, Gila L, Rodríguez J, Rodríguez I. A muscle architecture model offering control over motor unit fiber density distributions. Med Biol Eng Comput 2010; 48:875-86. [PMID: 20535575 DOI: 10.1007/s11517-010-0642-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2009] [Accepted: 05/13/2010] [Indexed: 11/29/2022]
Abstract
The aim of this study was to develop a muscle architecture model able to account for the observed distributions of innervation ratios and fiber densities of different types of motor units in a muscle. A model algorithm is proposed and mathematically analyzed in order to obtain an inverse procedure that allows, by modification of input parameters, control over the output distributions of motor unit fiber densities. The model's performance was tested with independent data from a glycogen depletion study of the medial gastrocnemius of the rat. Results show that the model accurately reproduces the observed physiological distributions of innervation ratios and fiber densities and their relationships. The reliability and accuracy of the new muscle architecture model developed here can provide more accurate models for the simulation of different electromyographic signals.
Collapse
Affiliation(s)
- Javier Navallas
- Department of Electric and Electronic Engineering, Public University of Navarra, Pamplona, Navarra, Spain.
| | | | | | | | | |
Collapse
|
33
|
Sung PS, Zurcher U, Kaufman M. Reliability difference between spectral and entropic measures of erector spinae muscle fatigability. J Electromyogr Kinesiol 2010; 20:25-30. [PMID: 19121587 DOI: 10.1016/j.jelekin.2008.11.005] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2008] [Revised: 10/03/2008] [Accepted: 11/23/2008] [Indexed: 11/17/2022] Open
Affiliation(s)
- Paul S Sung
- Department of Physical Therapy, College of Health Science, Korea University, Seoul, Republic of Korea.
| | | | | |
Collapse
|
34
|
|
35
|
Vieira TMM, Windhorst U, Merletti R. Is the stabilization of quiet upright stance in humans driven by synchronized modulations of the activity of medial and lateral gastrocnemius muscles? J Appl Physiol (1985) 2010; 108:85-97. [DOI: 10.1152/japplphysiol.00070.2009] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
A matrix of 120 electromyogram (EMG) electrodes (8 rows and 15 columns) was used to investigate individual activation patterns of the medial (MG) and lateral gastrocnemius (LG) muscles during forward sways of the body in human quiet stance. This matrix was positioned on the right calf of eight subjects after identification of the MG and LG contours with ultrasound scanning. Gray-scale images were generated with the maxima and minima of the cross-correlation function between the envelope of each EMG signal and the body center of pressure (CoP) for individual forward sways. These images were automatically segmented to reduce the data set into representative and local values of EMG-CoP cross-correlation for each muscle. On average, modulations in EMG amplitude preceded the onset of forward sways with a variable timing, with both gastrocnemius muscles being similarly and synchronously modulated in 193 out of 236 sways. Variations in the timing of activation between muscles were less frequent, although consistent across subjects and significantly correlated with changes in the direction and velocity of body sways. Interestingly, the time shift between EMG and CoP traces sometimes varied consistently along different channels of the same column of electrodes, either in proximal-to-distal or distal-to-proximal direction. The variable EMG-CoP cross-correlation delay was not congruent with the delay expected for the propagation of surface potentials along muscle fibers. Comparison of surface EMGs with intramuscular EMGs recorded from six subjects demonstrated that surface potentials provide high spatial selectivity, thus supporting the notion of selective activation of motor units during quiet standing. Hence, the stabilization of the quiet standing posture likely relies on flexible rather than stereotyped mechanisms of control.
Collapse
Affiliation(s)
- Taian M. M. Vieira
- Laboratory for Engineering of the Neuromuscular System, Politecnico di Torino, Torino, Italy
- Biomechanics Laboratory, School of Physical Education and Sports, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil; and
| | - Uwe Windhorst
- Consultant to Laboratory for Engineering of the Neuromuscular System, Politecnico di Torino, Torino, Italy
| | - Roberto Merletti
- Laboratory for Engineering of the Neuromuscular System, Politecnico di Torino, Torino, Italy
| |
Collapse
|
36
|
Navallas J, Malanda A, Gila L, Rodriguez J, Rodriguez I. Comparative evaluation of motor unit architecture models. Med Biol Eng Comput 2009; 47:1131-42. [DOI: 10.1007/s11517-009-0526-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2009] [Accepted: 08/03/2009] [Indexed: 11/27/2022]
|
37
|
Staats C, Austin D, Aboy M. A statistical model and simulator for cardiovascular pressure signals. Proc Inst Mech Eng H 2008; 222:991-8. [DOI: 10.1243/09544119jeim348] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Physiological signal simulators are often used to conduct validation studies of commercially available devices such as oscillometric non-invasive blood pressure (NIBP) monitors. Numerous assessment studies have been conducted using simulators to validate commercial NIBP monitors. While there are several simulators commercially available to evaluate oscillometric NIBP devices, currently there are no simulators designed to validate invasive pressure signal devices. A statistical model and simulator for invasive cardiovascular pressure signals such as arterial blood pressure and intracranial pressure are described. The model incorporates the effects of respiration on pressure signals and can be used to generate synthetic signals with time and frequency domain characteristics matching any desired subject population. Additionally, the way that noise and artefacts typically present in real pressure signals should be modelled is described. The proposed statistical model is a useful tool for validation of algorithms designed to process or analyse biomedical pressure signals to estimate parameters of clinical interest such as the cardiac frequency, heart rate variability, respiratory frequency, and pulse pressure variation in the presence of noise. The model can be used to simulate signals in order to validate commercial devices that process and analyse invasive pressure signals.
Collapse
Affiliation(s)
- C Staats
- Electrical Engineering Department, Oregon Institute of Technology, Beaverton, OR, USA
| | - D Austin
- Electrical Engineering Department, Oregon Institute of Technology, Beaverton, OR, USA
| | - M Aboy
- Electrical Engineering Department, Oregon Institute of Technology, Beaverton, OR, USA
| |
Collapse
|
38
|
Mesin L. Simulation of Surface EMG Signals for a Multilayer Volume Conductor With a Superficial Bone or Blood Vessel. IEEE Trans Biomed Eng 2008; 55:1647-57. [DOI: 10.1109/tbme.2008.919104] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
39
|
A simulation study for a surface EMG sensor that detects distinguishable motor unit action potentials. J Neurosci Methods 2008; 168:54-63. [PMID: 18029025 DOI: 10.1016/j.jneumeth.2007.09.007] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2007] [Revised: 08/21/2007] [Accepted: 09/11/2007] [Indexed: 11/30/2022]
Abstract
An advanced volume conductor model was used to simulate the surface-detected motor unit action potentials (MUAPs) due to current sources located at different depths within the muscle tissue of the biceps brachii. Seven different spatial filters were investigated by linear summation of the monopolarly detected surface MUAPs on a square array of nine electrodes. The criterion of the relative energy-of-difference (EOD) between the MUAPs was used to rank spatial filters for their ability to distinguish two motor units located at different depths. Using the same criterion pair wise combinations of spatial filters were ranked for their ability to generate different MUAP shape representations of the same motor unit. In both analyses, the bi-transversal double-differential (BiTDD) configurations and pair wise combinations involving a BiTDD configuration consistently ranked highest. Varying electrode spacing did not change the results in a relevant way. Based on the EOD calculations, a four-channel detection system using all available electrodes of the array is proposed. The implications of using only six electrodes, effectively reducing contact area of the sensor in half, are discussed.
Collapse
|
40
|
Dimitrov GV, Arabadzhiev TI, Hogrel JY, Dimitrova NA. Simulation analysis of interference EMG during fatiguing voluntary contractions. Part I: What do the intramuscular spike amplitude–frequency histograms reflect? J Electromyogr Kinesiol 2008; 18:26-34. [PMID: 16963279 DOI: 10.1016/j.jelekin.2006.06.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2005] [Revised: 06/15/2006] [Accepted: 06/27/2006] [Indexed: 10/24/2022] Open
Abstract
Decline in amplitude of EMG signals and in the rate of counts of intramuscularly recorded spikes during fatigue is often attributed to a progressive reduction of the neural drive only. As a rule, alterations in intracellular action potential (IAP) are not taken into account. To test correctness of the hypothesis, the effect of various discharge frequency patterns as well as changes in IAP shape and muscle fibre propagation velocity (MFPV) on the spike amplitude-frequency histogram of intramuscular interference EMG signals were simulated and analyzed. It was assumed that muscle was composed of four types of motor units (MUs): slow-twitch fatigue resistant, fast-twitch fatigue resistant, fast intermediate, and fast fatigable. MFPV and IAP duration at initial stage before fatigue as well as their changes differed for individual MU types. Fatigability of individual MU types in normal conditions as well as in the case of ischaemic or low oxygen conditions due to restricted blood flow was also taken into account. It was found that spike amplitude-frequency histogram is poorly sensitive to MU firing frequency, while it is highly sensitive to IAP profile lengthening. It is concluded that spike amplitude-frequency analysis can hardly provide a correct measure of MU rate-coding pattern during fatigue.
Collapse
Affiliation(s)
- G V Dimitrov
- Centre of Biomedical Engineering, Bulgarian Academy of Sciences, Acad. G. Bonchev Str., Bl. 105, Sofia 1113, Bulgaria.
| | | | | | | |
Collapse
|
41
|
Gabriel DA, Kamen G. Experimental and modeling investigation of spectral compression of biceps brachii SEMG activity with increasing force levels. J Electromyogr Kinesiol 2008; 19:437-48. [PMID: 18083563 DOI: 10.1016/j.jelekin.2007.10.009] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2007] [Revised: 10/23/2007] [Accepted: 10/24/2007] [Indexed: 11/30/2022] Open
Abstract
This study investigated possible motor unit (MU) firing patterns underlying changes in biceps brachii (BB) surface electromyographic (SEMG) activity in 96 participants who performed isometric actions of the elbow flexors at 40%, 60%, 80%, and 100% of maximum voluntary contraction (MVC). We also conducted a modeling investigation to determine the extent to which a model would fit the experimental results. Experimentally, there was a linear increase (277%; p<0.01) in root-mean-square (RMS) amplitude with increasing force. The mean power frequency (MNF) remained stable from 40% to 80% of MVC, but there was a decrease (8.2%; p<0.01) between 80% and 100% of MVC. A modeling approach was taken wherein well-known recruitment and rate-coding schemes activated MUs whose basic building block was the muscle fibre action potential. Two conditions were investigated: (1) an increase in firing rate (rate-coding) and (2) synchronization. The levels of rate-coding and synchronization were selected to produce a linear RMS-force relationship as observed in the experimental data. Then, the impact of these two strategies on changes in MNF was assessed. The MNF remained stable from 40% to 80% of maximum excitation for both the rate-coding and synchronization conditions. There was a decrease in MNF between 80% and 100% of maximum excitation for both modeling conditions, similar to that observed for the experimental data. Thus, at these high forces at which experimental data are technically difficult to obtain, the model supports the idea that both rate-coding and synchronization are responsible for the changes observed in surface EMG amplitude and frequency characteristics.
Collapse
Affiliation(s)
- David A Gabriel
- Electromyographic Kinesiology Laboratory, Faculty of Applied Health Sciences, Brock University, 500 Glenridge Avenue, St. Catharines, ON, Canada L2S 3A1.
| | | |
Collapse
|
42
|
Reffad A, Bekka RE, Mebarkia K, Chikouche D. Efficient parameterization of MUAP signal for identification of MU and volume conductor characteristics using neural networks. J Neurosci Methods 2007; 164:325-38. [PMID: 17544153 DOI: 10.1016/j.jneumeth.2007.04.015] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2007] [Revised: 04/15/2007] [Accepted: 04/22/2007] [Indexed: 11/25/2022]
Abstract
The motor unit action potential (MUAPs) shapes depend on the anatomy and the physiology of the contracted muscle. The aim of this work is the identification of some characteristics of the motor unit (MU) and the volume conductor, namely the MU depth, the innervation zone width and the thickness of fat and skin layers based on MUAP signal parameters. The relationship between these characteristics and MUAP parameters are non-linear and complex. Thus, the use of the neural networks approach becomes an efficient tool to put in evidence this relationship. We have used the similarity and the homogeneity of the parameter criterions to choose which parameters are appropriate for the extraction. Two identification systems are presented and compared, a global system and a separate one. In order to evaluate the performance of each system, we have tested them using several simulated MUAP signals corrupted with additive Gaussian noise at different signal to noise ratios (SNR). A new test is introduced in which the electrode radius, the bar electrode dimensions and inclination angles for the detection system, fixed during the training process, are changed.
Collapse
Affiliation(s)
- A Reffad
- Electronics Department, Engineering Faculty, Ferhat ABBAS University of Setif, 19000 Setif, Algeria.
| | | | | | | |
Collapse
|
43
|
Frigon A, Carroll TJ, Jones KE, Zehr EP, Collins DF. Ankle position and voluntary contraction alter maximal M waves in soleus and tibialis anterior. Muscle Nerve 2007; 35:756-66. [PMID: 17295303 PMCID: PMC5005069 DOI: 10.1002/mus.20747] [Citation(s) in RCA: 61] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Compound muscle action potentials (CMAPs) recorded using surface electrodes are often used to assess the excitability of neural pathways to skeletal muscle. However, the amplitude of CMAPs can be influenced by changes at the recording site, independent of mechanisms within the central nervous system. We quantified how joint angle and background contraction influenced CMAP amplitude. In seven subjects CMAPs evoked by supramaximal transcutaneous electrical stimulation of motor axons (M(max)) were recorded using surface electrodes from soleus and tibialis anterior (TA) at static positions over the full range of ankle movement at 5 degrees intervals. Across subjects the peak-to-peak amplitude of M(max) was 155% and 159% larger at the shortest than longest muscle lengths for soleus and TA, respectively. In five subjects the effect of ankle position and voluntary contraction on M-wave/H-reflex recruitment curves was assessed in the soleus. Both ankle position and level of contraction significantly influenced M(max), H(max), and the H(max) to M(max) ratio, but there were no interactions between the two parameters. These peripheral changes that influence M(max) will also impact other CMAPs such as submaximal M-waves, H-reflexes, and responses to transcranial magnetic stimulation. As such, during experimental studies CMAPs evoked at a given joint angle and contraction level should be normalized to M(max) recorded at similar joint angle and contraction strength.
Collapse
Affiliation(s)
- Alain Frigon
- Centre for Research in Neurological Sciences, Department of Physiology, Université de Montréal, Montréal, Québec, Canada
| | | | | | | | | |
Collapse
|
44
|
Abstract
Surface electromyography is used in research, to estimate the activity of muscle, in prosthetic design, to provide a control signal, and in biofeedback, to provide subjects with a visual or auditory indication of muscle contraction. Unfortunately, successful applications are limited by the variability in the signal and the consequent poor quality of estimates. I propose to use a nonlinear recursive filter based on Bayesian estimation. The desired filtered signal is modeled as a combined diffusion and jump process and the measured electromyographic (EMG) signal is modeled as a random process with a density in the exponential family and rate given by the desired signal. The rate is estimated on-line by calculating the full conditional density given all past measurements from a single electrode. The Bayesian estimate gives the filtered signal that best describes the observed EMG signal. This estimate yields results with very low short-time variability but also with the capability of very rapid response to change. The estimate approximates isometric joint torque with lower error and higher signal-to-noise ratio than current linear methods. Use of the nonlinear filter significantly reduces noise compared with current algorithms, and it may therefore permit more effective use of the EMG signal for prosthetic control, biofeedback, and neurophysiology research.
Collapse
Affiliation(s)
- Terence D Sanger
- Division of Child Neurology and Movement Disorders, Stanford University Medical Center, 300 Pasteur, Room A345, Stanford, CA 94305-5235.
| |
Collapse
|
45
|
Drost G, Stegeman DF, van Engelen BGM, Zwarts MJ. Clinical applications of high-density surface EMG: A systematic review. J Electromyogr Kinesiol 2006; 16:586-602. [PMID: 17085302 DOI: 10.1016/j.jelekin.2006.09.005] [Citation(s) in RCA: 189] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
High density-surface EMG (HD-sEMG) is a non-invasive technique to measure electrical muscle activity with multiple (more than two) closely spaced electrodes overlying a restricted area of the skin. Besides temporal activity HD-sEMG also allows spatial EMG activity to be recorded, thus expanding the possibilities to detect new muscle characteristics. Especially muscle fiber conduction velocity (MFCV) measurements and the evaluation of single motor unit (MU) characteristics come into view. This systematic review of the literature evaluates the clinical applications of HD-sEMG. Although beyond the scope of the present review, the search yielded a large number of "non-clinical" papers demonstrating that a considerable amount of work has been done and that significant technical progress has been made concerning the feasibility and optimization of HD-sEMG techniques. Twenty-nine clinical studies and four reviews of clinical applications of HD-sEMG were considered. The clinical studies concerned muscle fatigue, motor neuron diseases (MND), neuropathies, myopathies (mainly in patients with channelopathies), spontaneous muscle activity and MU firing rates. In principle, HD-sEMG allows pathological changes at the MU level to be detected, especially changes in neurogenic disorders and channelopathies. We additionally discuss several bioengineering aspects and future clinical applications of the technique and provide recommendations for further development and implementation of HD-sEMG as a clinical diagnostic tool.
Collapse
Affiliation(s)
- Gea Drost
- Department of Clinical Neurophysiology, Institute of Neurology, Radboud University Nijmegen Medical Centre, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands.
| | | | | | | |
Collapse
|
46
|
Mesin L. Simulation of Surface EMG Signals for a Multilayer Volume Conductor With Triangular Model of the Muscle Tissue. IEEE Trans Biomed Eng 2006; 53:2177-84. [PMID: 17073322 DOI: 10.1109/tbme.2006.879469] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
This study analytically describes surface electromyogram (sEMG) signals generated by a model of a triangular muscle, i.e., a muscle with fibers arranged in a fan shape. Examples of triangular muscles in the human body are the deltoid, the pectoralis major, the trapezius, the adductor pollicis. A model of triangular muscle is proposed. It is a sector of a cylindrical volume conductor (with the fibers directed along the radial coordinate) bounded at the muscle/fat interface. The muscle conductivity tensor reflects the fan anisotropy. Edge effects have been neglected. A solution of the nonspace invariant problem for a triangular muscle is provided in the Fourier domain. An approximate analytical solution for a two plane layer volume conductor model is obtained by introducing a homogeneous layer (modeling the fat) over the triangular muscle. The results are implemented in a complete sEMG generation model (including the finite length of the fibers), simulating single fiber action potentials. The model is not space invariant due to the changes of the volume conductor along the direction of action potential propagation. Thus the detected potentials at the skin surface change shape as they propagate. This determines problems in the extraction and interpretation of parameters. As a representative example of application of the simulation model, the influence of the inhomogeneity of the volume conductor in conduction velocity (CV) estimation is addressed (for two channels; maximum likelihood and reference point methods). Different fiber depths, electrode placements and small misalignments of the detection system with respect to the fiber have been simulated. The error in CV estimation is large when the depth of the fiber increases, when the detection system is not aligned with the fiber and close to the innervation point and to the tendons.
Collapse
Affiliation(s)
- Luca Mesin
- Laboratory for Neuromuscular System Engineering (LISiN), Dipartimento di Elettronica, Politecnico di Torino, Italy.
| |
Collapse
|
47
|
Staudenmann D, Kingma I, Daffertshofer A, Stegeman DF, van Dieën JH. Improving EMG-based muscle force estimation by using a high-density EMG grid and principal component analysis. IEEE Trans Biomed Eng 2006; 53:712-9. [PMID: 16602578 DOI: 10.1109/tbme.2006.870246] [Citation(s) in RCA: 112] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The accuracy of predictions of muscle force based on electromyography (EMG) is an important issue in biomechanics and kinesiology. Since human skeletal muscles show a high diversity and heterogeneity in their fiber architecture, it is difficult to properly align electrodes to the muscle fiber direction. Against this background, we analyzed the effect of different bipolar configuration directions on EMG-based force estimation. In addition, we investigated whether principal component analysis (PCA) can improve this estimation. High-density surface-EMG from the triceps brachii muscle and the extension force of the elbow were measured in 11 subjects. The root mean square difference (RMSD) between predicted and measured force was determined. We found the best bipolar configuration direction to cause a 13% lower RMSD relative to the worst direction. Optimal results were obtained with electrodes aligned with the expected main muscle fiber direction. We found that PCA reduced RMSD by about 40% compared to conventional bipolar electrodes and by about 12% compared to optimally aligned multiple bipolar electrodes. Thus, PCA contributes to the accuracy of EMG-based estimation of muscle force when using a high-density EMG grid.
Collapse
Affiliation(s)
- Didier Staudenmann
- Institute for Fundamental and Clinical Human Movement Sciences, Vrije Universiteit, Amsterdam BT 1081, The Netherlands.
| | | | | | | | | |
Collapse
|
48
|
Mesin L, Farina D. An analytical model for surface EMG generation in volume conductors with smooth conductivity variations. IEEE Trans Biomed Eng 2006; 53:773-9. [PMID: 16686399 DOI: 10.1109/tbme.2006.872825] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
A nonspace invariant model of volume conductor for surface electromyography (EMG) signal generation is analytically investigated. The volume conductor comprises planar layers representing the muscle and subcutaneous tissues. The muscle tissue is homogeneous and anisotropic while the subcutaneous layer is inhomogeneous and isotropic. The inhomogeneity is modeled as a smooth variation in conductivity along the muscle fiber direction. This may reflect a practical situation of tissues with different conductivity properties in different locations or of transitions between tissues with different properties. The problem is studied with the regular perturbation theory, through a series expansion of the electric potential. This leads to a set of Poisson's problems, for which the source term in an equation and the boundary conditions are determined by the solution of the previous equations. This set of problems can be solved iteratively. The solution is obtained in the two-dimensional Fourier domain, with spatial angular frequencies corresponding to the longitudinal and perpendicular direction with respect to the muscle fibers, in planes parallel to the detection surface. The series expansion is truncated for the practical implementation. Representative simulations are presented. The proposed model constitutes a new approach for surface EMG signal simulation with applications related to the validation of methods for information extraction from this signal.
Collapse
Affiliation(s)
- Luca Mesin
- Laboratorio di Ingegneria del Sistema Neuromuscolare (LISiN), Dipartimento di Elettronica, Politecnico di Torino, 10129 Torino, Italy
| | | |
Collapse
|
49
|
Hu XL, Tong KY, Li L. The mechanomyography of persons after stroke during isometric voluntary contractions. J Electromyogr Kinesiol 2006; 17:473-83. [PMID: 16603386 DOI: 10.1016/j.jelekin.2006.01.015] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2005] [Revised: 10/28/2005] [Accepted: 01/05/2006] [Indexed: 11/23/2022] Open
Abstract
This study was to investigate the properties of mechanomyography (MMG), or muscle sound, of the paretic muscle in the affected side of hemiplegic subjects after stroke during isometric voluntary contractions, in comparison with those from the muscle in the unaffected side of the hemiplegic subjects and from the healthy muscle of unimpaired subjects. MMG and electromyography (EMG) signals were recorded simultaneously from the biceps brachii muscles of the dominant arm of unimpaired subjects (n=5) and the unaffected and affected arms of subjects after stroke (n=8), when performing a fatiguing maximal voluntary contraction (MVC) associated with the decrease in elbow flexion torque, and then submaximal elbow flexions at 20%, 40%, 60% and 80% MVCs. The root mean squared (RMS) values, the mean power frequencies (MPF, in the power density spectrum, PDS) of the EMG and MMG, and the high frequency rate (HF-rate, the ratio of the power above 15Hz in the MMG PDS) were used for the analysis. The MMG RMS decreased more slowly during the MVC in the affected muscle compared to the healthy and unaffected muscles. A transient increase could be observed in the MMG MPFs from the unaffected and healthy muscles during the MVC, associated with the decrease in their simultaneous EMG MPFs due to the muscular fatigue. No significant variation could be seen in the EMG and MMG MPFs in the affected muscles during the MVC. The values in the MPF and HF-rate of MMG from the affected muscles were significantly lower than those from the healthy and unaffected muscles (P<0.05) at the high contraction level (80% MVC). Both the MMG and EMG RMS values in the healthy and unaffected groups were found to be significantly higher than the affected group (P<0.05) at 60% and 80% MVCs. These observations were related to an atrophy of the fast-twitch fibers and a reduction of the neural input in the affected muscles of the hemiplegic subjects. The results in this study suggested MMG could be used as a complementary to EMG for the analysis on muscular characteristics in subjects after stroke.
Collapse
Affiliation(s)
- X L Hu
- The Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Room ST417, Core S, Hong Kong
| | | | | |
Collapse
|
50
|
Mesin L, Joubert M, Hanekom T, Merletti R, Farina D. A Finite Element Model for Describing the Effect of Muscle Shortening on Surface EMG. IEEE Trans Biomed Eng 2006; 53:593-600. [PMID: 16602565 DOI: 10.1109/tbme.2006.870256] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
A finite-element model for the generation of single fiber action potentials in a muscle undergoing various degrees of fiber shortening is developed. The muscle is assumed fusiform with muscle fibers following a curvilinear path described by a Gaussian function. Different degrees of fiber shortening are simulated by changing the parameters of the fiber path and maintaining the volume of the muscle constant. The conductivity tensor is adapted to the muscle fiber orientation. In each point of the volume conductor, the conductivity of the muscle tissue in the direction of the fiber is larger than that in the transversal direction. Thus, the conductivity tensor changes point-by-point with fiber shortening, adapting to the fiber paths. An analytical derivation of the conductivity tensor is provided. The volume conductor is then studied with a finite-element approach using the analytically derived conductivity tensor. Representative simulations of single fiber action potentials with the muscle at different degrees of shortening are presented. It is shown that the geometrical changes in the muscle, which imply changes in the conductivity tensor, determine important variations in action potential shape, thus affecting its amplitude and frequency content. The model provides a new tool for interpreting surface EMG signal features with changes in muscle geometry, as it happens during dynamic contractions.
Collapse
Affiliation(s)
- Luca Mesin
- Laboratorio di Ingegneria del Sistema Neuromuscolare (LISiN), Dipartimento di Elettronica, Politecnico di Torino, 10129 Torino, Italy
| | | | | | | | | |
Collapse
|