1
|
He B, Zhang N, Peng M. Meta-analysis of the effect of entropy-assisted general anesthesia on the quality of postoperative recovery. Medicine (Baltimore) 2023; 102:e34091. [PMID: 37352057 PMCID: PMC10289486 DOI: 10.1097/md.0000000000034091] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Revised: 02/27/2023] [Accepted: 04/06/2023] [Indexed: 06/25/2023] Open
Abstract
BACKGROUND To evaluate the effect of the quality of postoperative anesthetic resuscitation in patients with entropy index monitoring assisted general anesthesia versus standard clinical practice. METHODS The randomized controlled trials on the application of entropy index monitoring in general anesthesia were searched in PubMed, Web of Science, Embase, The Cochrane Library, CNKI, Wanfang, VIP, and other databases by computer. The data were collected from inception to January 2022. Two researchers independently screened the retrieved literature according to the inclusion and exclusion criteria and used Cochrane's risk-of-bias assessment criteria to evaluate the quality of the literature. The evaluation indicators included respiratory recovery time, extubation time, consciousness recovery time, emergence agitation, postoperative nausea and vomiting (PONV), and intraoperative awareness. The RevMan 5.4.1 software was used for the meta-analysis of the data. RESULTS A total of 860 patients from 10 eligible randomized controlled trials were included in this study. The results showed that compared with the control group, the respiratory recovery time (MD = -3.37, 95% CI: -5.09 to -1.85, P < .0001), extubation time (MD = -4.57, 95% CI: -6.08 to -3.95, P < .00001), and consciousness recovery time (MD = -4.95, 95% CI: -7.21 to -2.70, P < .00001) in the entropy index group were significantly shortened. The incidence of emergence agitation in the entropy index group (RR = 0.23, 95% CI: 0.11-0.47, P < .0001) decreased significantly. The incidence of PONV (RR = 0.46, 95% CI: 0.27-0.79, P = .004) was significantly reduced. However, the incidence of intraoperative awareness (RR = 0.33, 95% CI: 0.04-3.16, P = .34) wasn't significantly different. CONCLUSION The application of the entropy index can improve the recovery quality of patients under general anesthesia, not only shortening the postoperative recovery time but also reducing the occurrence of agitation and PONV. It does not affect the incidence of intraoperative awareness.
Collapse
Affiliation(s)
- Bingyuan He
- Yongchuan Hospital of Chongqing Medical University, Chongqing, China
| | - Na Zhang
- Yongchuan Hospital of Chongqing Medical University, Chongqing, China
| | - Mingqing Peng
- Yongchuan Hospital of Chongqing Medical University, Chongqing, China
| |
Collapse
|
2
|
Validation of the patient State Index for monitoring sedation state in critically ill patients: a prospective observational study. J Clin Monit Comput 2023; 37:147-154. [PMID: 35661319 DOI: 10.1007/s10877-022-00871-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2022] [Accepted: 04/26/2022] [Indexed: 01/24/2023]
Abstract
PURPOSE The Patient State Index (PSI) is a newly introduced electroencephalogram-based tool for objective and continuous monitoring of sedation levels of patients under general anesthesia. This study investigated the potential correlation between the PSI and the Richmond Agitation‒Sedation Scale (RASS) score in intensive care unit (ICU) patients and established the utility of the PSI in assessing sedation levels. METHODS In this prospective observational study, PSI values were continuously monitored via SedLine® (Masimo, Irvine, CA, USA); the RASS score was recorded every 2 h for patients on mechanical ventilation. Physicians and nurses were blinded to the PSI values. Overall, 382 PSI and RASS score sets were recorded for 50 patients. RESULTS The PSI score correlated positively with RASS scores, and Spearman's rank correlation coefficient between the PSI and RASS was 0.79 (95% confidence interval [CI]: 0.75‒0.83). The PSI showed statistically significant difference among the RASS scores (Kruskal‒Wallis chi-square test: 242, df = 6, P < 2.2-e16). The PSI threshold for distinguishing light (RASS score ≥ - 2) sedation from deep sedation (RASS score ≤ - 3) was 54 (95% CI: 50-65; area under the curve, 0.92 [95% CI: 0.89‒0.95]; sensitivity, 0.91 [95% CI: 0.86‒0.95]; specificity, 0.81 [95% CI: 0.77-0.86]). CONCLUSIONS The PSI correlated positively with RASS scores, which represented a widely used tool for assessing sedation levels, and the values were significantly different among RASS scores. Additionally, the PSI had a high sensitivity and specificity for distinguishing light from deep sedation. The PSI could be useful for assessing sedation levels in ICU patients. University Hospital Medical Information Network (UMIN000035199, December 10, 2018).
Collapse
|
3
|
Jin S, Baik HJ, Cho S, Chung RK, Kong KA, Kim YJ. The influence of neuromuscular blockade on phase lag entropy and bispectral index: A randomized, controlled trial. PLoS One 2021; 16:e0257467. [PMID: 34520506 PMCID: PMC8439464 DOI: 10.1371/journal.pone.0257467] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Accepted: 08/31/2021] [Indexed: 11/18/2022] Open
Abstract
The aim of this study is to compare the effects of neuromuscular blockade (NMB) on phase lag entropy (PLE) and the bispectral index (BIS). We recorded the BIS, electromyograph (EMG) activity on a BIS monitor (EMG_BIS), PLE, and EMG activity on a PLE monitor (EMG_PLE) in 40 patients receiving general anesthesia. During the awake state, we analyzed the changes in parameters before and 2 min after the eyes were closed. During sedation, we compared the changes in the parameters before and at 4 min after injecting rocuronium (group R) or normal saline (group C) between the two groups. During anesthesia, we compared the changes in parameters before and at 4 min after injecting sugammadex (group B) or normal saline (group D) between the two groups. During the awake state, the BIS, EMG_BIS, and EMG_PLE, but not PLE, decreased significantly with closed eyes. An effect of EMG on the BIS was evident, but not on PLE. During sedation, the BIS decreased with the decrease in EMG_BIS regardless of NMB caused by rocuronium, but NMB decreased PLE, although the degree of the decrease in EMG_PLE after NMB was similar to that after placebo. To determine the effect of NMB on electroencephalograms (EEGs) in groups R and C, we plotted the power spectra before and at 4 min after injecting rocuronium or normal saline. Changes in slow and delta frequency bands were observed at 4 min after injecting rocuronium relative to before injecting rocuronium. There was no effect of EMG on either the BIS or PLE during anesthesia. In conclusion, the effect of electromyograph activity and/or neuromuscular blockade on BIS or PLE depends on the level of consciousness.
Collapse
Affiliation(s)
- Sohee Jin
- Department of Anesthesiology and Pain Medicine, Yonsei Barun Hospital, Seoul, Republic of Korea
| | - Hee Jung Baik
- Department of Anesthesiology and Pain Medicine, College of Medicine, Ewha Womans University, Ewha Womans University Mokdong Hospital, Seoul, Republic of Korea
| | - Sooyoung Cho
- Department of Anesthesiology and Pain Medicine, College of Medicine, Ewha Womans University, Ewha Womans University Mokdong Hospital, Seoul, Republic of Korea
| | - Rack Kyung Chung
- Department of Anesthesiology and Pain Medicine, College of Medicine, Ewha Womans University, Ewha Womans University Mokdong Hospital, Seoul, Republic of Korea
| | - Kyoung Ae Kong
- Department of Preventive Medicine, College of Medicine, Ewha Womans University, Seoul, Republic of Korea
| | - Youn Jin Kim
- Department of Anesthesiology and Pain Medicine, College of Medicine, Ewha Womans University, Ewha Womans University Seoul Hospital, Seoul, Republic of Korea
| |
Collapse
|
4
|
Nam SW, Oh AY, Koo BW, Kim BY, Han J, Chung SH. Effects of depth of neuromuscular blockade on the BIS-guided propofol requirement: A randomized controlled trial. Medicine (Baltimore) 2021; 100:e26576. [PMID: 34398011 PMCID: PMC8294904 DOI: 10.1097/md.0000000000026576] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/13/2021] [Accepted: 06/10/2021] [Indexed: 01/04/2023] Open
Abstract
BACKGROUND Deep neuromuscular blockade is considered beneficial for improving the surgical space condition during laparoscopic surgery. Adequacy of the surgical space condition may affect the anesthetists' decision regarding titration of depth of anesthesia. We investigated whether deep neuromuscular blockade reduces the propofol requirement under bispectral index monitoring compared to moderate neuromuscular blockade. METHODS Adult patients undergoing elective laparoscopic colorectal surgery were randomly allocated to a moderate or deep group. A train-of-four count of 1-2 in the moderate group, and a post-tetanic count of 1-2 in the deep group, were maintained by continuous infusion of rocuronium. The induction and maintenance of anesthesia were achieved by target-controlled infusion of propofol and remifentanil. The dose of propofol was adjusted to maintain the bispectral index in the range of 40-50. The remifentanil dose was titrated to maintain the systolic blood pressure to within 20% of the ward values. RESULTS A total of 82 patients were included in the analyses. The mean±SD dose of propofol was 7.54 ± 1.66 and 7.42 ± 1.01 mg·kg-1·h-1 in the moderate and deep groups, respectively (P = .104). The mean±SD dose of remifentanil was 4.84 ± 1.74 and 4.79 ± 1.77 μg kg-1 h-1 in the moderate and deep groups, respectively (P = .688). In comparison to the moderate group, the deep group showed significantly lower rates of intraoperative patient movement (42.9% vs 22.5%, respectively, P = .050) and additional neuromuscular blocking agent administration (76% vs 53%, respectively, P = .007). Postoperative complications, including pulmonary complications, wound problems and reoperation, were not different between the two groups. CONCLUSION Deep neuromuscular blockade did not reduce the bispectral index-guided propofol requirement compared to moderate neuromuscular blockade during laparoscopic colon surgery, despite reducing movement of the patient and the requirement for a rescue neuromuscular blocking agent. TRIAL REGISTRATION Clinicaltrials.gov (NCT03890406).
Collapse
Affiliation(s)
- Sun Woo Nam
- Department of Anesthesiology and Pain Medicine, Seoul National University Bundang Hospital, Seongnam
| | - Ah-Young Oh
- Department of Anesthesiology and Pain Medicine, Seoul National University Bundang Hospital, Seongnam
- Department of Anesthesiology and Pain Medicine, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Bon-Wook Koo
- Department of Anesthesiology and Pain Medicine, Seoul National University Bundang Hospital, Seongnam
| | - Bo Young Kim
- Department of Anesthesiology and Pain Medicine, Seoul National University Bundang Hospital, Seongnam
| | - Jiwon Han
- Department of Anesthesiology and Pain Medicine, Seoul National University Bundang Hospital, Seongnam
| | - Sung Hoon Chung
- Department of Anesthesiology and Pain Medicine, Seoul National University Bundang Hospital, Seongnam
| |
Collapse
|
5
|
Sanavia E, García M, del Castillo J, González R, López-Herce J, Mencía S. Efecto del bloqueo neuromuscular sobre la monitorización biespectral en los niños críticamente enfermos. An Pediatr (Barc) 2020; 93:251-256. [DOI: 10.1016/j.anpedi.2019.07.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2019] [Revised: 07/15/2019] [Accepted: 07/16/2019] [Indexed: 11/29/2022] Open
|
6
|
Dahaba AA. Benefits and boundaries of processed electroencephalography (pEEG) monitors when they do not concur with standard anesthetic clinical monitoring: lights and shadows. Minerva Anestesiol 2020; 86. [DOI: 10.23736/s0375-9393.19.13959-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/30/2023]
|
7
|
Sanavia E, García M, Castillo JD, González R, López-Herce J, Mencía S. Effect of neuromuscular blockade on the bispectral index in critically ill patients. An Pediatr (Barc) 2020; 93:251-256. [PMID: 34092338 DOI: 10.1016/j.anpede.2019.07.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2019] [Accepted: 07/16/2019] [Indexed: 12/20/2022] Open
Abstract
INTRODUCTION It has been suggested that neuromuscular blockade (NMB) affects the capacity of bispectral index (BIS) monitoring to measure consciousness in sedated children. Our aim was to analyse the impact of NMB on BIS values in critically ill children. METHODS We conducted a prospective observational study of children monitored with a BIS system that received a continuous infusion of vecuronium. We analysed data on clinical, diagnostic and haemodynamic variables, sedatives, analgesics, muscle relaxants, and BIS parameters. We compared BIS parameters before the use of a muscle relaxant, during its administration, before its discontinuation and for the 24h following the end of the infusion. RESULTS The analysis included 35 patients (median age, 30 months). The most common diagnosis was heart disease (85%). The most frequent indication for initiation of NMB was low cardiac output (45%), followed by adaptation to mechanical ventilation (20%). Neuromuscular blockade did not produce a significant change in BIS values. We found a decrease was observed in electromyography (EMG) values at 6h (34.9±9.4 vs 31.2±7; P=.008) and 12h after initiation of NMB (34.9±9.4 vs 28.6±4.8; P =.006). We observed a small significant increase in BIS after discontinuation of NMB (from 42.7±11 to 48.4±14.5, P=.001), and 6 and 12h later (51.3±16.6; P=.015). There were no differences in the doses of sedatives or analgesics except for fentanyl, of which the dose was lowered after discontinuation of vecuronium. CONCLUSION Continuous NMB produces small changes on BIS values that are not clinically significant and therefore does not interfere with BIS consciousness monitoring in critically ill children.
Collapse
Affiliation(s)
- Eva Sanavia
- Servicio de Pediatría, Hospital Infanta Leonor, Madrid, Spain
| | - Mirian García
- Unidad de Cuidados Intensivos Pediátricos, Hospital General Universitario Gregorio Marañón, Madrid, Spain; Facultad de Medicina, Universidad Complutense de Madrid, Madrid, Spain; Instituto de Investigación Sanitaria Gregorio Marañón, Red de Salud Materno Infantil y del Desarrollo (RedSAMID), Madrid, Spain.
| | - Jimena Del Castillo
- Unidad de Cuidados Intensivos Pediátricos, Hospital General Universitario Gregorio Marañón, Madrid, Spain; Facultad de Medicina, Universidad Complutense de Madrid, Madrid, Spain; Instituto de Investigación Sanitaria Gregorio Marañón, Red de Salud Materno Infantil y del Desarrollo (RedSAMID), Madrid, Spain
| | - Rafael González
- Unidad de Cuidados Intensivos Pediátricos, Hospital General Universitario Gregorio Marañón, Madrid, Spain; Facultad de Medicina, Universidad Complutense de Madrid, Madrid, Spain; Instituto de Investigación Sanitaria Gregorio Marañón, Red de Salud Materno Infantil y del Desarrollo (RedSAMID), Madrid, Spain
| | - Jesús López-Herce
- Unidad de Cuidados Intensivos Pediátricos, Hospital General Universitario Gregorio Marañón, Madrid, Spain; Facultad de Medicina, Universidad Complutense de Madrid, Madrid, Spain; Instituto de Investigación Sanitaria Gregorio Marañón, Red de Salud Materno Infantil y del Desarrollo (RedSAMID), Madrid, Spain
| | - Santiago Mencía
- Unidad de Cuidados Intensivos Pediátricos, Hospital General Universitario Gregorio Marañón, Madrid, Spain; Facultad de Medicina, Universidad Complutense de Madrid, Madrid, Spain; Instituto de Investigación Sanitaria Gregorio Marañón, Red de Salud Materno Infantil y del Desarrollo (RedSAMID), Madrid, Spain
| |
Collapse
|
8
|
Le Guen M, Roussel C, Chazot T, Dumont GA, Liu N, Fischler M. Reversal of neuromuscular blockade with sugammadex during continuous administration of anaesthetic agents: a double‐blind randomised crossover study using the bispectral index. Anaesthesia 2019; 75:583-590. [DOI: 10.1111/anae.14897] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/20/2019] [Indexed: 12/17/2022]
Affiliation(s)
- M. Le Guen
- Department of Anaesthesiology Hospital Foch Suresnes and University Versailles Saint‐Quentin en Yvelines France
| | - C. Roussel
- Department of Anaesthesiology Hospital Foch Suresnes and University Versailles Saint‐Quentin en Yvelines France
| | - T. Chazot
- Department of Anaesthesiology Hospital Foch Suresnes and University Versailles Saint‐Quentin en Yvelines France
| | - G. A. Dumont
- Department of Electrical and Computer Engineering University of British Columbia Vancouver BC Canada
| | - N. Liu
- Department of Anaesthesiology Hospital Foch Suresnes and University Versailles Saint‐Quentin en Yvelines France
| | - M. Fischler
- Department of Anaesthesiology Hospital Foch Suresnes and University Versailles Saint‐Quentin en Yvelines France
| |
Collapse
|
9
|
Xing Y, Xu D, Xu Y, Chen L, Wang H, Li S. Effects of Neuromuscular Blockages on Entropy Monitoring During Sevoflurane Anesthesia. Med Sci Monit 2019; 25:8610-8617. [PMID: 31729355 PMCID: PMC6873634 DOI: 10.12659/msm.917879] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
Background There are no data available on the effects of different degrees of neuromuscular blockade on spectral entropy during sevoflurane anesthesia. This study aimed to observe the effects of different degrees of neuromuscular blockade on state and response entropy during sevoflurane anesthesia. Material/Methods Eighty-one female patients were randomized to 9 groups (n=9 per group) according to the concentration of sevoflurane and degree of neuromuscular blockade. Response and state entropy were monitored. The endpoints were: 1) impact of neuromuscular blockade on state entropy and response entropy, and the difference between response entropy and state entropy; and 2) the response of entropy after cutaneous tetanic electrical noxious stimulation to the ulnar nerve under different degrees of neuromuscular blockade and concentrations of sevoflurane. Results These were no significant differences in response entropy or state entropy, or differences between response entropy and state entropy among the groups in the awake state (P>0.05). Without noxious stimulation, sevoflurane concentrations and neuromuscular blockade had no significant effects on response entropy or state entropy, or on the difference between response entropy and state entropy (all P>0.05), but sevoflurane concentrations showed a significant effect on state entropy (P<0.05). After noxious stimulation, sevoflurane concentrations and neuromuscular blockade had significant effects on response entropy and state entropy, and on the difference between response entropy and state entropy. Conclusions Response entropy and state entropy decreased with increasing sevoflurane concentration. Neuromuscular blockade did not affect entropy without noxious stimulation. With stimulation, muscle relaxants significantly reduced the changes in entropy, and there were significant effects of neuromuscular blockade and sevoflurane on entropy.
Collapse
Affiliation(s)
- Yian Xing
- Department of Anesthesiology, Shanghai General Hospital of Nanjing Medical University, Shanghai, China (mainland)
| | - Dian Xu
- Department of Anesthesiology, Shanghai General Hospital of Nanjing Medical University, Shanghai, China (mainland)
| | - Yanyifang Xu
- Department of Anesthesiology, Shanghai General Hospital of Nanjing Medical University, Shanghai, China (mainland)
| | - Lianhua Chen
- Department of Anesthesiology, Shanghai General Hospital of Nanjing Medical University, Shanghai, China (mainland)
| | - Hong Wang
- Department of Anesthesiology, Shanghai General Hospital of Nanjing Medical University, Shanghai, China (mainland)
| | - Shitong Li
- Department of Anesthesiology, Shanghai General Hospital of Nanjing Medical University, Shanghai, China (mainland)
| |
Collapse
|
10
|
Jung D, Yang S, Lee MS, Lee Y. Remifentanil Alleviates Propofol-Induced Burst Suppression without Affecting Bispectral Index in Female Patients: A Randomized Controlled Trial. J Clin Med 2019; 8:jcm8081186. [PMID: 31398849 PMCID: PMC6722898 DOI: 10.3390/jcm8081186] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2019] [Revised: 08/05/2019] [Accepted: 08/06/2019] [Indexed: 01/27/2023] Open
Abstract
The bispectral index is affected by various factors, such as noxious stimuli and other drugs, such as muscle relaxants. The burst suppression ratio from bispectral index monitoring is correlated with electroencephalographic burst suppression, which is associated with deep anesthesia, metabolic disorders, and brain injury. We assessed patients undergoing total intravenous anesthesia and examined the effects of remifentanil on the bispectral index, burst suppression ratio, and hemodynamic changes immediately after loss of consciousness with propofol. Seventy American Society of Anesthesiologists physical status class I and II Korean female patients scheduled for general anesthesia were administered propofol with an effect-site concentration of 5 μg/mL, using a target-controlled infusion (TCI). After losing consciousness, patients received either saline or remifentanil at an effect-site concentration of 5 ng/mL for 10 min. During this period, we recorded the bispectral index values, including burst suppression ratio, blood pressure, and heart rate. With remifentanil infusion, burst suppression ratios were lower (p < 0.01) but bispectral values were not different. The burst suppression ratio was significantly different at 6, 7, 8, and 10 min after remifentanil infusion (p < 0.05). In female patients with propofol-induced unconsciousness, remifentanil alleviated the burst suppression ratio without affecting the bispectral value.
Collapse
Affiliation(s)
- Dahye Jung
- Department of Anesthesiology and Pain Medicine, Changwon Fatima Hospital, Changwon 51394, Korea
- Department of Anesthesiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Banpo-daero, Seocho-gu, Seoul 06591, Korea
| | - Sungwon Yang
- Department of Anesthesiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Banpo-daero, Seocho-gu, Seoul 06591, Korea
| | - Min Soo Lee
- Department of Anesthesiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Banpo-daero, Seocho-gu, Seoul 06591, Korea
| | - Yoonki Lee
- Department of Anesthesiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Banpo-daero, Seocho-gu, Seoul 06591, Korea.
| |
Collapse
|
11
|
Behavior of a dual closed-loop controller of propofol and remifentanil guided by the bispectral index for postoperative sedation of adult cardiac surgery patients: a preliminary open study. J Clin Monit Comput 2019; 34:779-786. [PMID: 31327103 DOI: 10.1007/s10877-019-00360-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2018] [Accepted: 07/16/2019] [Indexed: 10/26/2022]
Abstract
A dual-loop controller permits the automated titration of propofol and remifentanil during anesthesia; it has never been used in intensive care after cardiac surgery. The goal of this preliminary study was to determine the efficacy of this controller to provide postoperative sedation in 19 adult cardiac surgery patients with a Bispectral Index target of 50. Results are presented as numbers (percentages) or medians [25th-75th percentiles]. The sedation period lasted 139 min [89-205] during which the Richmond Agitation Sedation Scale was at - 5 and the Behavioral Pain Scale score at three points for all patients and observation times but one (82 out of 83 assessments). Sedation time in the range 40-60 for the Bispectral Index was 87% [57-95]; one patient had a period of electrical silence defined as Suppression Ratio at least > 10% for more than 60 s. The time between the end of infusions and tracheal extubation was 84 min [63-129]. The Richmond Agitation Sedation Scale was 0 [0-0], 0 [- 1 to 0], and 0 [0-0] respectively during the 3 h following extubation while the verbal numerical pain scores were 6 [4.5-7], 5 [4-6], and 2 [0-5]. Mean arterial pressure decreased during sedation requiring therapeutic interventions, mainly vascular filling in 15 (79%) patients. Automated sedation device was discontinued in two patients for hemodynamic instability. No patient had awareness of the postoperative sedation period. Dual closed-loop can provide postoperative sedation after cardiac surgery but the choice of the depth of sedation should take into account the risk of hypotension.
Collapse
|
12
|
Ferreira AL, Nunes C, Mendes JG, Amorim P. Do we have today a reliable method to detect the moment of loss of consciousness during induction of general anaesthesia? REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION 2019; 66:93-103. [PMID: 30077394 DOI: 10.1016/j.redar.2018.06.008] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/08/2018] [Revised: 06/03/2018] [Accepted: 06/13/2018] [Indexed: 06/08/2023]
Abstract
This review aims to give an overview of the current state of monitoring depth of anaesthesia and detecting the moment of loss of consciousness, from the first clinical signs involved in anaesthesia to the latest technologies used in this area. Such techniques are extremely important for the development of automatic systems for anaesthesia control, including preventing intraoperative awareness episodes and overdoses. A search in the databases Pubmed and IEEE Xplore was performed using terms such anaesthetic monitoring, depth of anaesthesia, loss of consciousness, as well as anaesthesia indexes, namely BIS. Despite the several methods capable of monitoring the hypnotic state of anaesthesia, there is still no methodology to accurate detect the moment of loss of consciousness during induction of general anaesthesia.
Collapse
Affiliation(s)
- A L Ferreira
- LAETA/INEGI, Faculdade de Engenharia da Universidade do Porto, Oporto, Portugal; Centro de Investigação Clínica em Anestesiologia, Serviço de Anestesiologia, Centro Hospitalar do Porto, Oporto, Portugal.
| | - C Nunes
- Centro de Investigação Clínica em Anestesiologia, Serviço de Anestesiologia, Centro Hospitalar do Porto, Oporto, Portugal; Departamento de Ciências e Tecnologia, Universidade Aberta, Oporto, Portugal
| | - J G Mendes
- LAETA/INEGI, Faculdade de Engenharia da Universidade do Porto, Oporto, Portugal
| | - P Amorim
- Centro de Investigação Clínica em Anestesiologia, Serviço de Anestesiologia, Centro Hospitalar do Porto, Oporto, Portugal
| |
Collapse
|
13
|
Hayashi K, Sawa T. The fundamental contribution of the electromyogram to a high bispectral index: a postoperative observational study. J Clin Monit Comput 2019; 33:1097-1103. [PMID: 30607805 DOI: 10.1007/s10877-018-00244-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2018] [Accepted: 12/22/2018] [Indexed: 12/19/2022]
Abstract
The electromyogram (EMG) activity has been reported to falsely increase BIS. Conversely, EMG seems necessary to constitute the high BIS indicative of an awake condition, and may play a fundamental role in calculating BIS, rather than distorting the appropriate BIS. However, exactly how EMG is associated with a high BIS remains unclear. We intended to clarify the respective contributions of EMG and various electroencephalogram (EEG) parameters to high BIS. In 79 courses of anaesthesia, BIS monitor-derived EMG parameters (EMGLOW), and other processed EEG parameters [SEF95 (spectral edge frequency 95%), SynchFastSlow (bispectral parameter), BetaRatio (frequency parameter), total power subtypes in five frequency range], were obtained simultaneously with BIS, every 3 s. These EEG parameters were used for receiver operating characteristic (ROC) analysis of detecting three BIS levels (BIS > 80, BIS > 70, and BIS > 60) to assess their diagnosabilities. A total of 218,418 data points derived from 79 cases were used for analysis. Area under the ROC curve (AUC) was calculated and optimal cut-off (threshold) was determined by Youden index. As the results, for detecting BIS > 80, the AUC of EMGLOW was 0.975 [0.974-0.977] (mean [95% confidence interval]), significantly higher than any other processed EEG parameters such as BetaRatio (0.832 [0.828-0.835]), SEF95 (0.821 [0.817-0.826]) and SynchFastSlow (0.769 [0.764-0.774]) (p < 0.05 each). The threshold of EMGLOW for detecting BIS > 80 was 35.7 dB, with high sensitivity (92.5%) and high specificity (96.5%). Our results suggest EMG contributes considerably to the diagnosis of high BIS, and is particularly essential for determining BIS > 80.
Collapse
Affiliation(s)
- Kazuko Hayashi
- Department of Anesthesiology, Kyoto Chubu Medical Center, Yagi Ueno 25, Nantan, Kyoto, 629-0917, Japan.
| | - Teiji Sawa
- Department of Anesthesiology and Critical Care, Kyoto Prefectural University of Medicine, Kyoto, Japan
| |
Collapse
|
14
|
Kim YS, Chung D, Oh SK, Won YJ, Lee IO. Unusual elevation in Entropy but not in PSI during general anesthesia: a case report. BMC Anesthesiol 2018; 18:22. [PMID: 29444638 PMCID: PMC5813332 DOI: 10.1186/s12871-018-0486-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2017] [Accepted: 02/02/2018] [Indexed: 11/25/2022] Open
Abstract
Background EEG monitoring is useful for determining an adequate level of anesthesia. However it is sometimes interfered by various reasons. We describe a case in which we successfully confirmed the adequate depth of anesthesia by monitoring the patient state index (PSI), which was computed from the SedLine monitor data in Root (Masimo) during general anesthesia. Our case showed unusual elevations in entropy, but not in PSI. Case presentation A 34-year-old woman was scheduled for emergency surgery for a left tibial open fracture and a right femoral closed fracture, which were sustained during a traffic accident. Forty-five minutes after intubation, the response entropy abruptly increased up to 100 and state entropy to 91. Despite the absence of other abnormal events, the entropy data led to two types of incorrect decisions. The first was owing to the effect of the EMG and the second was misleading during the surgeon’s hammering. However, PSI from the SedLine monitor seemed to be less influenced by the same events. Conclusions In this report, we suggest that the PSI, derived from new-generation SedLine (Root, Masimo) may be a useful parameter for clinically determining the level of sedation. The use of two monitoring devices with different EEG algorithms might be helpful for determining the anesthetic depth and making decisions. Electronic supplementary material The online version of this article (10.1186/s12871-018-0486-8) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Young Sung Kim
- Department of Anesthesiology and Pain Medicine, Korea University Guro Hospital, 148 Gurodong-ro, Guro-gu, Seoul, 08308, South Korea
| | - Dongik Chung
- Department of Anesthesiology and Pain Medicine, Korea University Guro Hospital, 148 Gurodong-ro, Guro-gu, Seoul, 08308, South Korea
| | - Seok Kyeong Oh
- Department of Anesthesiology and Pain Medicine, Korea University Guro Hospital, 148 Gurodong-ro, Guro-gu, Seoul, 08308, South Korea
| | - Young Ju Won
- Department of Anesthesiology and Pain Medicine, Korea University Guro Hospital, 148 Gurodong-ro, Guro-gu, Seoul, 08308, South Korea
| | - Il Ok Lee
- Department of Anesthesiology and Pain Medicine, Korea University Guro Hospital, 148 Gurodong-ro, Guro-gu, Seoul, 08308, South Korea.
| |
Collapse
|
15
|
Messina AG, Wang M, Ward MJ, Wilker CC, Smith BB, Vezina DP, Pace NL. Anaesthetic interventions for prevention of awareness during surgery. Cochrane Database Syst Rev 2016; 10:CD007272. [PMID: 27755648 PMCID: PMC6461159 DOI: 10.1002/14651858.cd007272.pub2] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
BACKGROUND General anaesthesia is usually associated with unconsciousness. 'Awareness' is when patients have postoperative recall of events or experiences during surgery. 'Wakefulness' is when patients become conscious during surgery, but have no postoperative recollection of the period of consciousness. OBJECTIVES To evaluate the efficacy of two types of anaesthetic interventions in reducing clinically significant awareness:- anaesthetic drug regimens; and- intraoperative anaesthetic depth monitors. SEARCH METHODS We searched the Cochrane Central Register of Controlled Trials (CENTRAL, ISSUE 4 2016); PubMed from 1950 to April 2016; MEDLINE from 1950 to April 2016; and Embase from 1980 to April 2016. We contacted experts to identify additional studies. We performed a handsearch of the citations in the review. We did not search trial registries. SELECTION CRITERIA We included randomized controlled trials (RCTs) of either anaesthetic regimens or anaesthetic depth monitors. We excluded volunteer studies, studies of patients prior to skin incision, intensive care unit studies, and studies that only randomized different word presentations for memory tests (not anaesthetic interventions).Anaesthetic drug regimens included studies of induction or maintenance, or both. Anaesthetic depth monitors included the Bispectral Index monitor, M-Entropy, Narcotrend monitor, cerebral function monitor, cerebral state monitor, patient state index, and lower oesophageal contractility monitor. The use of anaesthetic depth monitors allows the titration of anaesthetic drugs to maintain unconsciousness. DATA COLLECTION AND ANALYSIS At least two authors independently scanned abstracts, extracted data from the studies, and evaluated studies for risk of bias. We made attempts to contact all authors for additional clarification. We performed meta-analysis statistics in packages of the R language. MAIN RESULTS We included 160 studies with 54,109 enrolled participants; 53,713 participants started the studies and 50,034 completed the studies or data analysis (or both). We could not use 115 RCTs in meta-analytic comparisons because they had zero awareness events. We did not merge 27 of the remaining 45 studies because they had excessive clinical and methodological heterogeneity. We pooled the remaining 18 eligible RCTs in meta-analysis. There are 10 studies awaiting classification which we will process when we update the review.The meta-analyses included 18 trials with 36,034 participants. In the analysis of anaesthetic depth monitoring (either Bispectral Index or M-entropy) versus standard clinical and electronic monitoring, there were nine trials with 34,744 participants. The overall event rate was 0.5%. The effect favoured neither anaesthetic depth monitoring nor standard clinical and electronic monitoring, with little precision in the odds ratio (OR) estimate (OR 0.98, 95% confidence interval (CI) 0.59 to 1.62).In a five-study subset of Bispectral Index monitoring versus standard clinical and electronic monitoring, with 34,181 participants, 503 participants gave awareness reports to a blinded, expert panel who adjudicated or judged the outcome for each patient after reviewing the questionnaires: no awareness, possible awareness, or definite awareness. Experts judged 351 patient awareness reports to have no awareness, 87 to have possible awareness, and 65 to have definite awareness. The effect size favoured neither Bispectral Index monitoring nor standard clinical and electronic monitoring, with little precision in the OR estimate for the combination of definite and possible awareness (OR 0.96, 95% CI 0.35 to 2.65). The effect size favoured Bispectral Index monitoring for definite awareness, but with little precision in the OR estimate (OR 0.60, 95% CI 0.13 to 2.75).We performed three smaller meta-analyses of anaesthetic drugs. There were nine studies with 1290 participants. Wakefulness was reduced by ketamine and etomidate compared to thiopental. Wakefulness was more frequent than awareness. Benzodiazepines reduces awareness compared to thiopental, ketamine, and placebo., Also, higher doses of inhaled anaesthetics versus lower doses reduced the risk of awareness.We graded the quality of the evidence as low or very low in the 'Summary of findings' tables for the five comparisons.Most of the secondary outcomes in this review were not reported in the included RCTs. AUTHORS' CONCLUSIONS Anaesthetic depth monitors may have similar effects to standard clinical and electrical monitoring on the risk of awareness during surgery. In older studies comparing anaesthetics in a smaller portion of the patient sample, wakefulness occurred more frequently than awareness. Use of etomidate and ketamine lowered the risk of wakefulness compared to thiopental. Benzodiazepines compared to thiopental and ketamine, or higher doses of inhaled anaesthetics versus lower doses, reduced the risk of awareness.
Collapse
Affiliation(s)
- Anthony G Messina
- School of Management, University of Texas at DallasThe Alliance for Medical Management EducationBox 2331920 N. Coit RoadRichardsonTXUSA75080
| | - Michael Wang
- University of LeicesterClinical Psychology UnitLancaster RoadLeicesterUKLE1 7HA
| | - Marshall J Ward
- Dartmouth‐Hitchcock Medical Center1 Medical Center DrLebanonNHUSA03766
| | - Chase C Wilker
- ARUP LaboratoriesClinical Toxicology IIISalt Lake CityUTUSA
| | - Brett B Smith
- University of UtahUniversity of Utah School of MedicineSalt Lake CityUTUSA84112
| | - Daniel P Vezina
- University of UtahDepartment of Anesthesiology, Department of Internal Medicine, Division of CardiologySalt Lake CityUTUSA
- Veteran's AdministrationEchocardiography LaboratorySalt Lake CityUTUSA
| | - Nathan Leon Pace
- University of UtahDepartment of Anesthesiology3C444 SOM30 North 1900 EastSalt Lake CityUTUSA84132‐2304
| | | |
Collapse
|
16
|
Escontrela Rodríguez B, Gago Martínez A, Merino Julián I, Martínez Ruiz A. Spectral entropy in monitoring anesthetic depth. REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION 2016; 63:471-478. [PMID: 26431743 DOI: 10.1016/j.redar.2015.07.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2015] [Revised: 06/30/2015] [Accepted: 07/14/2015] [Indexed: 06/05/2023]
Abstract
Monitoring the brain response to hypnotics in general anesthesia, with the nociceptive and hemodynamic stimulus interaction, has been a subject of intense investigation for many years. Nowadays, monitors of depth of anesthesia are based in processed electroencephalogram by different algorithms, some of them unknown, to obtain a simplified numeric parameter approximate to brain activity state in each moment. In this review we evaluate if spectral entropy suitably reflects the brain electric behavior in response to hypnotics and the different intensity nociceptive stimulus effect during a surgical procedure.
Collapse
Affiliation(s)
- B Escontrela Rodríguez
- Servicio Anestesiología y Reanimación, Hospital Universitario de Cruces, Barakaldo, Vizcaya, España.
| | - A Gago Martínez
- Servicio Anestesiología y Reanimación, Hospital Universitario de Cruces, Barakaldo, Vizcaya, España
| | - I Merino Julián
- Servicio Anestesiología y Reanimación, Hospital Universitario de Cruces, Barakaldo, Vizcaya, España
| | - A Martínez Ruiz
- Servicio Anestesiología y Reanimación, Hospital Universitario de Cruces, Barakaldo, Vizcaya, España; Facultad de Medicina, Universidad del País Vasco, Leioa, Vizcaya, España
| |
Collapse
|
17
|
Kim E, Ryu JH, Byun SH. Effect of neuromuscular blockade reversal by pyridostigmine on spectral entropy values during recovery from desflurane anesthesia: a prospective, randomized, double-blind, controlled trial. Korean J Anesthesiol 2016; 69:227-33. [PMID: 27274366 PMCID: PMC4891533 DOI: 10.4097/kjae.2016.69.3.227] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2015] [Revised: 01/30/2016] [Accepted: 02/03/2016] [Indexed: 12/17/2022] Open
Abstract
BACKGROUND According to several studies investigating the relationship between muscle activity and electroencephalogram results, reversal of neuromuscular blockade (NMB) may affect depth of anesthesia indices. Therefore, we investigated the effect of pyridostigmine on these indices via spectral entropy. METHODS Fifty-six patients scheduled for thyroidectomy or parotidectomy were included in this study and randomized into two groups. At the start of skin suturing, the desflurane concentration was adjusted to 4.2 vol% in both groups. Following this, the pyridostigmine group (group P, n = 28) was administered pyridostigmine 0.2 mg/kg mixed with glycopyrrolate 0.04 mg/kg, while the control group (group C, n = 28) received normal saline. Entropy values (response entropy [RE] and state entropy [SE]), train of four (TOF) ratio, and end-tidal desflurane concentration were recorded from point of drug administration to 15 minutes post-drug administration. RESULTS Mean RE values at 15 minutes, when the maximum effect of pyridostigmine was anticipated, showed a statistically significant difference between groups (53.8 ± 10.5 in group P and 48.0 ± 8.8 in group C; P = 0.030). However, mean SE at 15 minutes showed no significant difference between the two groups (P = 0.066). At 15 minutes, there were significant differences in the TOF ratio between the two groups (P < 0.001). CONCLUSIONS NMB reversal by pyridostigmine significantly increased RE values but not SE values. This finding suggests that spectral entropy may be a useful alternative tool for monitoring anesthetic depth during recovery from anesthesia in the presence of electromyogram activity.
Collapse
Affiliation(s)
- Eugene Kim
- Department of Anesthesiology and Pain Medicine, Catholic University of Daegu School of Medicine, Daegu, Korea
| | - Jae Hun Ryu
- Department of Anesthesiology and Pain Medicine, Catholic University of Daegu School of Medicine, Daegu, Korea
| | - Sung Hye Byun
- Department of Anesthesiology and Pain Medicine, Catholic University of Daegu School of Medicine, Daegu, Korea
| |
Collapse
|
18
|
Puttappa A, Sheshadri K, Boylan J, Conlon N. Large increases in both response and state entropy to awake values antagonized with administration of incremental rocuronium. Br J Anaesth 2015; 115:934-5. [PMID: 26582856 DOI: 10.1093/bja/aev385] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
19
|
Rao AK, Gurajala I, Gopinath R. Comparison of electroencephalogram entropy versus loss of verbal response to determine the requirement of propofol for induction of general anaesthesia. Indian J Anaesth 2015. [PMID: 26195830 PMCID: PMC4481753 DOI: 10.4103/0019-5049.158738] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
Background and Aims: Propofol causes dose-dependent reduction in blood pressure (BP). This study was done to evaluate the use of spectral entropy on the dose of propofol required and the haemodynamic stability during induction of general anaesthesia (GA). Methods: In this randomised controlled study, 72 American Society of Anesthesiologists’ physical status I and II patients undergoing general and orthopaedic surgeries were divided into Group S (n-36) and Group C (n-36). Patients in Group C were induced with propofol till loss of response to verbal commands and in Group S until the state entropy was <50 and state and response entropy difference was <10. The induction dose of propofol, haemodynamic parameters and the entropy values were recorded. Numerical data were expressed as a mean ± standard deviation and analysed using unpaired, two-tailed t-test. Categorical data were compared using Chi-square test. P < 0.05 value was considered significant. Results: The dose of propofol per kg was significantly more in the entropy group (1.80 ± 0.23 mg/kg in the Group C and 1.98 ± 0.217 mg/kg in the Group S [P < 0.05]). After induction, at intubation and 1 min after intubation, entropy values were lower in Group S than Group C (P < 0.05). The BP decreased significantly after induction compared with the baseline (P < 0.05), but there was no difference between the groups. Conclusion: Propofol required for induction of GA when guided by electroencephalogram entropy was significantly higher than the induction dose based on loss of verbal response. Both conventional induction and induction with entropy as the endpoint resulted in similar haemodynamic profile.
Collapse
Affiliation(s)
- Akasapu Karunakara Rao
- Department of Anaesthesiology, Rajiv Gandhi Institute of Medical Sciences, Srikakulam, Andhra Pradesh, India
| | - Indira Gurajala
- Department of Anaesthesiology and Critical Care, Nizam's Institute of Medical Sciences, Hyderabad, Telangana, India
| | - Ramachandran Gopinath
- Department of Anaesthesiology and Critical Care, Nizam's Institute of Medical Sciences, Hyderabad, Telangana, India
| |
Collapse
|
20
|
Schuller P, Newell S, Strickland P, Barry J. Response of bispectral index to neuromuscular block in awake volunteers. Br J Anaesth 2015; 115 Suppl 1:i95-i103. [DOI: 10.1093/bja/aev072] [Citation(s) in RCA: 143] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023] Open
|
21
|
Sharma A, Singh PM, Trikha A, Rewari V. Entropy correlates with Richmond Agitation Sedation Scale in mechanically ventilated critically ill patients. J Clin Monit Comput 2014; 28:193-201. [PMID: 24122077 DOI: 10.1007/s10877-013-9517-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2012] [Accepted: 10/04/2013] [Indexed: 11/26/2022]
Abstract
Sedation is routinely used in intensive care units. However due to absence of objective scoring systems like Bispectral Index and entropy our ability to regulate the degree of sedation is limited. This deficiency is further highlighted by the fact that agitation scores used in intensive care units (ICU) have no role in paralyzed patients. The present study compares entropy as a sedation scoring modality with Richmond Agitation Sedation Scale (RASS) in mechanically ventilated, critically ill patients in an ICU. Twenty-seven, mechanically ventilated, critically ill patients of either sex, 16-65 years of age, were studied over a period of 24 h. They received a standard sedation regimen consisting of a bolus dose of propofol 0.5 mg/kg and fentanyl 1 lg/kg followed by infusions of propofol and fentanyl ranging from 1.5 to 5 mg/kg/h and 0.5 to 2.0 lg/kg/h, respectively. Clinically relevant values of RASS for optimal ICU sedation (between 0 and -3) in non-paralyzed patients were compared to corresponding entropy values, to find if any significant correlation exists between the two. These entropy measurements were obtained using the Datex-Ohmeda-M-EntropyTM module. This module is presently not approved by Food and Drug Administration (FDA) for monitoring sedation in ICU. A total of 527 readings were obtained. There was a statistically significant correlation between the state entropy (SE) and RASS [Spearman's rho/rs = 0.334, p\0.0001]; response entropy (RE) and RASS [Spearman's rho/rs = 0.341, p\0.0001]). For adequate sedation as judged by a RASS value of 0 to -3, the mean SE was 57.86 ± 16.50 and RE was 67.75 ± 15.65. The present study illustrates that entropy correlates with RASS (between scores 0 and -3) when assessing the level of sedation in mechanically ventilated critically ill patients.
Collapse
|
22
|
Influence of neuromuscular block and reversal on bispectral index and NeuroSense values. Eur J Anaesthesiol 2014; 31:437-9. [DOI: 10.1097/eja.0b013e32836394df] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
23
|
Jagadeesan N, Wolfson M, Chen Y, Willingham M, Avidan MS. Brain monitoring during general anesthesia. TRENDS IN ANAESTHESIA AND CRITICAL CARE 2013. [DOI: 10.1016/j.tacc.2012.12.003] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
24
|
Automated sedation outperforms manual administration of propofol and remifentanil in critically ill patients with deep sedation: a randomized phase II trial. Intensive Care Med 2012; 39:454-62. [PMID: 23223772 DOI: 10.1007/s00134-012-2762-2] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2012] [Accepted: 11/05/2012] [Indexed: 01/14/2023]
Abstract
PURPOSE To compare automated administration of propofol and remifentanil guided by the Bispectral index (BIS) versus manual administration of short-acting drugs in critical care patients requiring deep sedation. The primary outcome was the percentage of BIS values between 40 and 60 (BIS(40-60)). METHODS This randomized controlled phase II trial in the intensive care unit (ICU) was conducted in adults with multiorgan failure. Thirty-one patients were assigned to receive sedation with propofol or remifentanil either by an automated or a manual system, both targeting BIS(40-60). Performance and feasibility of an automated administration were assessed. RESULTS The study groups were well balanced in terms of demographic characteristics. Study duration averaged 18 [8-24] h in the automated group and 14 [9-21] h in the manual group (p = 0.81). Adequate sedation (BIS(40-60)) was significantly more frequent in the automated group 77 [59-82] % than in the manual group 36 [22-56] %, with p = 0.001. Propofol consumption was reduced by a factor of 2 in the automated group with a median change of infusion rates of 39 ± 9 times per hour. In contrast, there were only 2 ± 1 propofol and 1 ± 1 remifentanil dose changes per hour in the manual group compared to 40 ± 9 for remifentanil in the automated group (p < 0.001). Vasopressors were more often discontinued or reduced in the automated group than in the manual control group (36 [6-40] vs. 12 [4-20] modifications, p = 0.03). CONCLUSIONS Continuous titration of propofol and remifentanil sedation with an automatic controller maintains deep sedation better than manual control in severely ill patients. It is associated with reduced sedative and vasopressor use.
Collapse
|
25
|
van Kralingen S, Diepstraten J, Peeters MYM, Deneer VHM, van Ramshorst B, Wiezer RJ, van Dongen EPA, Danhof M, Knibbe CAJ. Population pharmacokinetics and pharmacodynamics of propofol in morbidly obese patients. Clin Pharmacokinet 2012; 50:739-50. [PMID: 21973271 DOI: 10.2165/11592890-000000000-00000] [Citation(s) in RCA: 57] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
BACKGROUND AND OBJECTIVES In view of the increasing prevalence of morbidly obese patients, the influence of excessive total bodyweight (TBW) on the pharmacokinetics and pharmacodynamics of propofol was characterized in this study using bispectral index (BIS) values as a pharmacodynamic endpoint. METHODS A population pharmacokinetic and pharmacodynamic model was developed with the nonlinear mixed-effects modelling software NONMEM VI, on the basis of 491 blood samples from 20 morbidly obese patients (TBW range 98-167 kg) and 725 blood samples from 44 lean patients (TBW range 55-98 kg) from previously published studies. In addition, 2246 BIS values from the 20 morbidly obese patients were available for pharmacodynamic analysis. RESULTS In a three-compartment pharmacokinetic model, TBW proved to be the most predictive covariate for clearance from the central compartment (CL) in the 20 morbidly obese patients (CL 2.33 L/min × [TBW/70]^[0.72]). Similar results were obtained when the morbidly obese patients and the 44 lean patients were analysed together (CL 2.22 L/min × [TBW/70]^[0.67]). No covariates were identified for other pharmacokinetic parameters. The depth of anaesthesia in the morbidly obese patients was adequately described by a two-compartment biophase-distribution model with a sigmoid maximum possible effect (E(max)) pharmacodynamic model (concentration at half-maximum effect [EC(50)] 2.12 mg/L) without covariates. CONCLUSION We developed a pharmacokinetic and pharmacodynamic model of propofol in morbidly obese patients, in which TBW proved to be the major determinant of clearance, using an allometric function with an exponent of 0.72. For the other pharmacokinetic and pharmacodynamic parameters, no covariates could be identified. Trial registration number (clinicaltrials.gov): NCT00395681.
Collapse
Affiliation(s)
- Simone van Kralingen
- Department of Anesthesiology and Intensive Care, St Antonius Hospital, Nieuwegein, the Netherlands
| | | | | | | | | | | | | | | | | |
Collapse
|
26
|
Dahaba A, Bornemann H, Hopfgartner E, Ohran M, Kocher K, Liebmann M, Wilfinger G, Metzler H. Effect of sugammadex or neostigmine neuromuscular block reversal on bispectral index monitoring of propofol/remifentanil anaesthesia. Br J Anaesth 2012; 108:602-606. [DOI: 10.1093/bja/aer495] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/30/2023] Open
|
27
|
Kim HM, Shin SW, Yoon JY, Lee HJ, Kim KH, Baik SW. Effects of etomidate on bispectral index scale and spectral entropy during induction of anesthesia by means of the raw electroencephalographic and electromyographic characteristics. Korean J Anesthesiol 2012; 62:230-3. [PMID: 22474548 PMCID: PMC3315651 DOI: 10.4097/kjae.2012.62.3.230] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2011] [Revised: 06/13/2011] [Accepted: 07/16/2011] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND Etomidate frequently induces myoclonus, so it may affect electromyographics (EMG). And EMG commonly has an effect on the bispectral index scale (BIS) and spectral entropy. This study was performed to compare the effect of etomidate on BIS, response entropy (RE) and state entropy (SE) during induction of anesthesia. METHODS Fifty patients (ASA I or II) scheduled for elective surgery were included in this study. Anesthesia was induced with etomidate (0.3 mg/kg) and rocuronium (0.6 mg/kg). Patients also inhaled 4 vol% sevoflurane and 100% oxygen and, then intubated. BIS, RE, SE and Modified Observer's Assessment of Alertness/Sedation Scale (MOAA/S) were measured 4 times (before injection of etomidate [T0], at loss of eyelash reflex [T1], 90 seconds after rocuronium injection [T2], and after intubation [T3]). We also checked whether myoclonus occurred. RESULTS Baseline values (T0) were 93.1 ± 4.7 for BIS, 95.8 ± 3.7 for RE and, 87.3 ± 3.5 for SE. In comparison with T0, there were significantly differences in BIS (50.2 ± 16.3), RE (76.8 ± 18.5) and SE (66.3 ± 17.4) at T1 (all P < 0.05). There were no significant differences at T2 and T3. Thirty one patients had myoclonus. At the occurrence of myoclonus, RE and SE values significantly increased but not BIS (P < 0.05). CONCLUSIONS In patients with myoclonus, at the loss of consciousness, spectral entropy did not decrease where as BIS did, suggesting that BIS may evaluate hypnotic levels better than spectral entropy during induction of anesthesia with etomidate.
Collapse
Affiliation(s)
- Hyun-Mok Kim
- Department of Anesthesia and Pain Medicine, Pusan National University School of Medicine, Yangsan, Korea
| | - Sang-Wook Shin
- Department of Anesthesia and Pain Medicine, Pusan National University School of Medicine, Yangsan, Korea
| | - Ji-Young Yoon
- Department of Anesthesia and Pain Medicine, Pusan National University School of Medicine, Yangsan, Korea
| | - Hyeon-Jeong Lee
- Department of Anesthesia and Pain Medicine, Pusan National University School of Medicine, Yangsan, Korea
| | - Kyung-Hoon Kim
- Department of Anesthesia and Pain Medicine, Pusan National University School of Medicine, Yangsan, Korea
| | - Seong-Wan Baik
- Department of Anesthesia and Pain Medicine, Pusan National University School of Medicine, Yangsan, Korea
| |
Collapse
|
28
|
Time-frequency analysis of somatosensory evoked potentials for intraoperative spinal cord monitoring. J Clin Neurophysiol 2012; 28:504-11. [PMID: 21946365 DOI: 10.1097/wnp.0b013e318231c15c] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
PURPOSE To evaluate the potential use of time-frequency analysis and its reliability in intraoperative somatosensory evoked potential (SEP) monitoring. METHODS One hundred ninety-one patients undergoing thoracic and/or lumbar spinal surgery were studied retrospectively. The SEP signals were recorded during different stages of surgery. Averaged SEP was analyzed by short-time Fourier transform. The main peak in the time-frequency interpretation of SEP was measured in peak power, peak time, and peak frequency. The variability of these parameters was compared with that of amplitude and latency during different stages of surgery. The reliability of these parameters was also compared in true-positive and false-positive cases. RESULTS During different surgical stages for the posterior tibial nerve SEP, the intrasubject variability of peak power was found to be more stable than that of amplitude, while the intrasubject variability of peak time did not show any difference compared with that of latency. The peak frequency presented stable during surgery. Moreover, the true-positive SEP case showed that peak power may detect the potential injury earlier than amplitude does. The false-positive outcomes could be reduced by the proposed method. CONCLUSIONS The SEP peak component was found stable and reliable during the different stages of surgery. For clinical application purpose, time-frequency analysis was suggested to be an additional monitoring method besides the conventional amplitude/latency measurement since it provided a more reproducible and prompt response to the potential injury in intraoperative SEP monitoring.
Collapse
|
29
|
Jeong SJ, Han JI, Baik HJ, Lee H, Lee GY, Kim JH. The effect of pyridostigmine on bispectral index during recovery from sevoflurane anesthesia. Korean J Anesthesiol 2011; 61:460-4. [PMID: 22220221 PMCID: PMC3249566 DOI: 10.4097/kjae.2011.61.6.460] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2011] [Revised: 03/09/2011] [Accepted: 03/15/2011] [Indexed: 11/26/2022] Open
Abstract
Background There have been some conflicting reports showing that muscle relaxants and anticholinesterases affect the level of the bispectral index (BIS). The purpose of this study was to investigate whether pyridostigmine affects the level of the BIS during recovery from sevoflurane anesthesia. Methods Fifty-two adult patients scheduled for laparoscopic cholecystectomy and laparoscopic appendectomy. Anesthesia was induced with thiopental 4 mg/kg and rocuronium 0.6 mg/kg. The lung was mechanically ventilated with 1-3 vol% sevoflurane, 50% oxygen and 50% nitrous oxide. After a specimen was removed, the sevoflurane concentration was maintained at 1.5 vol%. When skin closure began, sevoflurane was stopped; however, 50% oxygen and 50% nitrous oxide were maintained. The patients then received either (1) a group that received an injection of glycopyrrolate 0.04 mg/kg and pyridostigmine 0.2 mg/kg (reverse (R) group, n = 26) or (2) a group that received normal saline (control (C) group, n = 26). Group assignment was random. Pyridostigmine, a reversible cholinesterase inhibitor, is a parasympathomimetic. End-tidal sevoflurane concentration, train of four (TOF) ratio, bispectral index (BIS), blood pressure and heart rate were measured from the end of the operation to 15 min after inject of pyridostigmine or placebo. Results There were no significant between group differences in the time dependent decrease in end-tidal sevoflurane concentration (P = 0.0642). There were significant differences between the two groups for the time course for increases in the TOF value (P < 0.0001). There were significant differences between the two groups for the time course for increases in the BIS value (P = 0.0107). There were no significant differences in the mean BIS value up to 10 minutes after administering drug, but 15 minutes after administrating the reverse drug or the control drug, the BIS value showed significantly different BIS values: 68.2 ± 6.2 (Group R) and 63.2 ± 6.2 (Group C) (P = 0.0058). Conclusions The finding that pyridostigmine increases TOF and BIS suggests that pyridostigmine may enhance recovery during recovery from sevoflurane anesthesia.
Collapse
Affiliation(s)
- Seol-Joo Jeong
- Department of Anesthesiology and Pain Medicine, School of Medicine, Ewha Womans University, Seoul, Korea
| | | | | | | | | | | |
Collapse
|
30
|
Chazot T, Dumont G, Le Guen M, Hausser-Hauw C, Liu N, Fischler M. Sugammadex administration results in arousal from intravenous anaesthesia: a clinical and electroencephalographic observation. Br J Anaesth 2011; 106:914-6. [DOI: 10.1093/bja/aer142] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
|
31
|
Comparison of spectral entropy and BIS VISTA™ monitor during general anesthesia for cardiac surgery. J Clin Monit Comput 2011; 25:95-103. [PMID: 21512777 DOI: 10.1007/s10877-011-9280-6] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2011] [Accepted: 04/08/2011] [Indexed: 10/18/2022]
Abstract
OBJECTIVES We compared the primary metrics of the Spectral entropy M-ENTROPY™ module and BIS VISTA™ monitor-i.e., bispectral index (BIS), state entropy (SE), and response entropy (RE) in terms of agreement and correlation during general anesthesia for cardiac surgery. We also evaluated responsiveness of electroencephalogram (EEG)-based and hemodynamic parameters to surgical noxious stimulation, skin incision, and sternotomy, hypothesizing that RE would be a better responsiveness predictor. METHODS BIS and entropy sensors were applied before anesthesia induction in 32 patients having elective cardiac surgery. Total intravenous anesthesia was standardized and guided by the BIS index with neuromuscular blockade tested with train-of-four monitoring. Parameters included SE, RE, BIS, forehead electromyography (EMG), and hemodynamic variables. Time points for analyzing BIS, entropy, and hemodynamic values were 1 min before and after: anesthesia induction, intubation, skin incision, sternotomy, cannulation of the aorta, cardiopulmonary bypass (CPB), cross-clamping the aorta, de-clamping the aorta, and end of CPB; also after starting the re-warming phase and at 10, 20, 30, and 40 min following. RESULTS The mean difference between BIS and SE (Bland-Altman) was 2.14 (+16/- 11; 95% CI 1.59-2.67), and between BIS and RE it was 0.02 (+14/- 14; 95% CI 0.01-0.06). BIS and SE (r(2) = 0.66; P = 0.001) and BIS and RE (r(2) = 0.7; P = 0.001) were closely correlated (Pearson's). EEG parameters, EMG values, and systolic blood pressure significantly increased after skin incision, and sternotomy. The effect of surgical stimulation (Cohen's d) was highest for RE after skin incision (-0.71; P = 0.0001) and sternotomy (-0.94; P = 0.0001). CONCLUSION Agreement was poor between the BIS index measured by BIS VISTA™ and SE values at critical anesthesia time points in patients undergoing cardiac surgery. RE was a good predictor of arousal after surgical stimulation regardless of the surgical level of muscle relaxation. Index differences most likely resulted from different algorithms for calculating consciousness level.
Collapse
|
32
|
Mustola S, Toivonen J. Effect-site concentration of remifentanil attenuating surgical stress index responses to intubation of the trachea. Anaesthesia 2010; 65:581-585. [DOI: 10.1111/j.1365-2044.2010.06329.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
33
|
Baulig W, Seifert B, Schmid ER, Schwarz U. Comparison of spectral entropy and bispectral index electroencephalography in coronary artery bypass graft surgery. J Cardiothorac Vasc Anesth 2009; 24:544-9. [PMID: 19945300 DOI: 10.1053/j.jvca.2009.09.013] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/17/2009] [Indexed: 11/11/2022]
Abstract
OBJECTIVE The study's aim was to compare response entropy (RE) and state entropy (SE) with bispectral index (BIS) electroencephalography (EEG) as an alternative cerebral monitoring tool in patients scheduled for coronary artery bypass graft surgery. DESIGN Prospective, observational single-center study. SETTING University hospital. PARTICIPANTS Thirty patients undergoing coronary artery bypass graft surgery receiving remifentanil-propofol anesthesia. INTERVENTIONS Surgery was performed with cardiopulmonary bypass (CPB) and cardiac arrest in 15 patients, with CPB without cardiac arrest in 9 patients and without CPB in 6 patients. MEASUREMENTS AND MAIN RESULTS RE, SE, BIS, burst suppression ratio (BSR), and frontal electromyography (f-EMG) were detected simultaneously. RE and SE compared favorably with BIS and their correlations were strong (r(2) = 0.6, r(2) = 0.55, respectively). The mean bias of RE and BIS was -1.8, but limits of agreement were high (+20.5/-24.1). RE and SE tended to be lower than the BIS values in the CPB subgroups. The detection of BSR was similar with RE and SE and the BIS. A strong correlation existed between BIS and f-EMG (r(2) = 0.62) in contrast to RE (r(2) = 0.45) and SE (r(2) =0.39). BIS monitoring was significantly more disturbed than RE and SE with 9.1% +/-10.9% and 0.1% +/- 0.2% of the total anesthesia time, respectively. Neither implicit nor explicit memory was shown. CONCLUSION RE and SE are comparable with the BIS but showed significantly less interference from f-EMG and superior resistance against artifacts. Thus, spectral entropy is more suitable than the BIS during propofol-remifentanil anesthesia in cardiac surgery patients.
Collapse
Affiliation(s)
- Werner Baulig
- Division of Cardiac Anaesthesia, University Hospital Zurich, Zurich, Switzerland.
| | | | | | | |
Collapse
|
34
|
Doufas AG, Komatsu R, Orhan-Sungur M, Sengupta P, Wadhwa A, Mascha E, Shafer SL, Sessler DI. Neuromuscular Block Differentially Affects Immobility and Cortical Activation at Near–Minimum Alveolar Concentration Anesthesia. Anesth Analg 2009; 109:1097-104. [DOI: 10.1213/ane.0b013e3181af631a] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
35
|
Fakhari S, Bilehjani E, Azarfarin R, Kianfar AA, Mirinazhad M, Negargar S. Anesthesia in adult cardiac surgery without maintenance of muscle relaxants: a randomized clinical trial. Pak J Biol Sci 2009; 12:1111-1118. [PMID: 19899321 DOI: 10.3923/pjbs.2009.1111.1118] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
There may be no need for muscle paralysis during cardiac surgery when adequate anesthesia is provided. We studied intra- and post-operative conditions during cardiac surgery without maintenance muscle relaxant therapy. Eighty adult patients who were candidates for elective coronary artery bypass graft surgery were randomly allocated into two groups. In the noMR or study group (noMR group; n = 40) only an intubation dose of cisatracurium (0.15 mg kg(-1)) was administrated, as opposed to the control group (MR group; n = 40), who had a continuous infusion added to the intubation dose. The anesthesia level was maintained at a Bispectral score of 40-50 using a propofol infusion. A remifentanil infusion was titrated to control patient hemodynamic response. During surgery, any minor (fine body or respiratory muscle movements) or major (coarse body movements or bucking/caught) movements were recorded. Postoperatively, analgesia was provided by remifentanil. The surgical condition was classified into three states: good (no movement), acceptable (minor movements), or poor (major movements). Anesthesia, surgery and postoperative characteristics were compared between the two groups. Statistical analysis was performed in only 78 patients (noMR = 38, MR = 40). The demographic and preoperative characteristics of the two groups were comparable. Intra-operative propofol consumption was the same, but significantly more remifentanil was used in the noMR group (p = 0.001). Post-operative characteristics and complication rates did not differ between the two groups. There were no movements in the MR group patients, while in the noMR group one patient had major movement and three had minor movements. We concluded that omitting maintenance muscle relaxants in adult cardiac surgery or eliminating residual muscle paralysis at the end of the surgery without improving early outcome can increase patient intra-operative movement risk.
Collapse
Affiliation(s)
- S Fakhari
- Madani Heart Hospital, Tabriz University of Medical Sciences, Tabriz, Iran
| | | | | | | | | | | |
Collapse
|
36
|
Bennett C, Voss LJ, Barnard JPM, Sleigh JW. Practical Use of the Raw Electroencephalogram Waveform During General Anesthesia: The Art and Science. Anesth Analg 2009; 109:539-50. [DOI: 10.1213/ane.0b013e3181a9fc38] [Citation(s) in RCA: 106] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
37
|
Is your patient sleeping? Eur J Anaesthesiol 2009; 26:704-6. [PMID: 19455043 DOI: 10.1097/eja.0b013e328329488e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
38
|
Shoda E, Kitagawa J, Suzuki I, Nitta-Kubota I, Miyamoto M, Tsuboi Y, Kondo M, Masuda Y, Oi Y, Ren K, Iwata K. Increased phosphorylation of extracellular signal-regulated kinase in trigeminal nociceptive neurons following propofol administration in rats. THE JOURNAL OF PAIN 2009; 10:573-85. [PMID: 19398380 DOI: 10.1016/j.jpain.2008.11.013] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2008] [Revised: 11/13/2008] [Accepted: 11/18/2008] [Indexed: 01/23/2023]
Abstract
UNLABELLED Although propofol (PRO) is widely used in clinic as a hypnotic agent, the underlying mechanisms of its action on pain pathways is still unknown. Sprague-Dawley rats were assigned to receive PRO or pentobarbital (PEN) and were divided into 2 groups as LIGHT and DEEP hypnotic levels based on the EEG analysis. Rats in each hypnotic level received capsaicin injection into the face and phosphorylated extracellular signal-regulated kinase (pERK) immunohistochemistry was performed in subnucleus caudalis (Vc) and upper cervical spinal cord. In the rats with PEN or PRO administration, a large number of pERK-like immunoreactive (LI) cells was observed in the trigeminal spinal subnuclei interpolaris and caudalis transition zone (Vi/Vc), middle Vc, and transition zone between Vc and upper cervical spinal cord (Vc/C2) following capsaicin injection into the whisker-pad region. The number of pERK-LI cells in Vi/Vc, middle Vc, and Vc/C2 was significantly larger in rats with PRO infusion than those with PEN infusion. The number of pERK-LI cells was increased following an increase in the dose of PRO but not in PEN. The pERK-LI cells were mainly distributed in the Vi/Vc, middle Vc, and Vc/C2 after the bolus infusion of PRO. The expression of pERK-LI cells was depressed after the intravenous lidocaine application before bolus PRO infusion. The present findings suggest that PRO induced an enhancement of the activity of trigeminal nociceptive pathways through nociceptors innervating the venous structure, as indicated by a lidocaine-sensitive increase in pERK. This may explain deep pain around the injection regions during intravenous bolus infusion of PRO. PERSPECTIVE The effect of propofol administration on ERK phosphorylation in the subregions of the spinal trigeminal complex and upper cervical spinal cord neurons were precisely analyzed in rats with PRO infusion. A large number of pERK-LI cells was observed following intravenous PRO administration, suggesting an enhancement of trigeminal nociceptive activity and that PRO may produce pain through nociceptors innervating the venous structures during infusion.
Collapse
Affiliation(s)
- Emi Shoda
- Department of Anesthesiology, Nihon University School of Dentistry, Tokyo, Japan
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
39
|
Kim BS, Lee SI, Choi SU, Shin HW, Lim HJ, Lee HW, Chang SH, Yoon SM. Effect of muscle relaxant on entropy during propofol anesthesia. Korean J Anesthesiol 2009; 56:381-386. [PMID: 30625757 DOI: 10.4097/kjae.2009.56.4.381] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The purpose of this study was to investigate whether muscle relaxant affect the values of Entropy, response entropy (RE) or state entropy (SE) during propofol anesthesia. METHODS Eighty patients (ASA I) scheduled for elective surgery under general anesthesia were randomly assigned to four groups. Anesthesia was maintained at a SE value of 80 (80 +/- 2) using target controlled infusion (TCI) of propofol. After maintaining SE 80 for 5 min, vecuronium 0.1 mg/kg was injected intravenously in group I and same volume of normal saline was intravenously injected in group II. After maintaining SE 60 for 5 min, vecuronium 0.1 mg/kg was injected intravenously in group III and same volume of normal saline was injected intravenously in group IV. The mean arterial pressure, heart rate, SE and RE were measured before anesthetic induction and up to 5 min after vecuronium or normal saline injection in each group. RESULTS SE and RE were not changed in group II, but significantly decreased in group I (P < 0.05, respectively). In group III and IV, SE and RE were not changed in both groups. There were no significant hemodynamic changes among the four groups. CONCLUSIONS These results suggest that the effect of muscle relaxant on Entropy vary according to the baseline values of RE or SE during propofol anesthesia.
Collapse
Affiliation(s)
- Bo Song Kim
- Department of Anesthesiology and Pain Medicine, College of Medicine, Korea University, Seoul, Korea.
| | - Sang Ik Lee
- Department of Anesthesiology and Pain Medicine, College of Medicine, Korea University, Seoul, Korea.
| | - Sung Uk Choi
- Department of Anesthesiology and Pain Medicine, College of Medicine, Korea University, Seoul, Korea.
| | - Hye Won Shin
- Department of Anesthesiology and Pain Medicine, College of Medicine, Korea University, Seoul, Korea.
| | - Hae Ja Lim
- Department of Anesthesiology and Pain Medicine, College of Medicine, Korea University, Seoul, Korea.
| | - Hye Won Lee
- Department of Anesthesiology and Pain Medicine, College of Medicine, Korea University, Seoul, Korea.
| | - Seong Ho Chang
- Department of Anesthesiology and Pain Medicine, College of Medicine, Korea University, Seoul, Korea.
| | - Suk Min Yoon
- Department of Anesthesiology and Pain Medicine, College of Medicine, Korea University, Seoul, Korea.
| |
Collapse
|
40
|
Delta sleep-inducing peptide alters bispectral index, the electroencephalogram and heart rate variability when used as an adjunct to isoflurane anaesthesia. Eur J Anaesthesiol 2009; 26:128-34. [DOI: 10.1097/eja.0b013e32831c8644] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
41
|
Abstract
One of the most important mandates of the anaesthesiologist is to control the depth of anaesthesia. An unsolved problem is that a straight definition of the depth of anaesthesia does not exist. Concerning this it is rational to separate hypnosis from analgesia, from muscle relaxation and from block of cardiovascular reactions. Clinical surrogate parameters such as blood pressure and heart rate are not well-suited for a valid statement about the depth of hypnosis. To answer this question the brain has become the focus of interest as the target of anaesthesia. It is possible to visualize the brain's electrical activity from anelectroencephalogram (EEG). The validity of the spontaneous EEG as an anesthetic depth monitor is limited by the multiphasic activity, especially when anaesthesia is induced (excitation) and in deep anaesthesia (burst suppression). Recently, various commercial monitoring systems have been introduced to solve this problem. These monitoring systems use different interpretations of the EEG or auditory-evoked potentials (AEP). These derived and calculated variables have no pure physiological basis. For that reason a profound knowledge of the algorithms and a validation of the monitoring systems is an indispensable prerequisite prior to their routine clinical use. For the currently available monitoring systems various studies have been reported. At this time it is important to know that the actual available monitors can only value the sedation and not the other components of anaesthesia. For example, they cannot predict if a patient will react to a painful stimulus or not. In the future it would be desirable to develop parameters which allow an estimate of the other components of anaesthesia in addition to the presently available monitoring systems to estimate sedation and muscle relaxation. These could be sensoric-evoked potentials to estimate analgesia and AEPs for the detection of awareness.
Collapse
|
42
|
Haenggi M, Ypparila-Wolters H, Bieri C, Steiner C, Takala J, Korhonen I, Jakob SM. Entropy and bispectral index for assessment of sedation, analgesia and the effects of unpleasant stimuli in critically ill patients: an observational study. Crit Care 2008; 12:R119. [PMID: 18796156 PMCID: PMC2592749 DOI: 10.1186/cc7015] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2008] [Revised: 08/26/2008] [Accepted: 09/16/2008] [Indexed: 11/22/2022] Open
Abstract
Introduction Sedative and analgesic drugs are frequently used in critically ill patients. Their overuse may prolong mechanical ventilation and length of stay in the intensive care unit. Guidelines recommend use of sedation protocols that include sedation scores and trials of sedation cessation to minimize drug use. We evaluated processed electroencephalography (response and state entropy and bispectral index) as an adjunct to monitoring effects of commonly used sedative and analgesic drugs and intratracheal suctioning. Methods Electrodes for monitoring bispectral index and entropy were placed on the foreheads of 44 critically ill patients requiring mechanical ventilation and who previously had no brain dysfunction. Sedation was targeted individually using the Ramsay Sedation Scale, recorded every 2 hours or more frequently. Use of and indications for sedative and analgesic drugs and intratracheal suctioning were recorded manually and using a camera. At the end of the study, processed electroencephalographical and haemodynamic variables collected before and after each drug application and tracheal suctioning were analyzed. Ramsay score was used for comparison with processed electroencephalography when assessed within 15 minutes of an intervention. Results The indications for boli of sedative drugs exhibited statistically significant, albeit clinically irrelevant, differences in terms of their association with processed electroencephalographical parameters. Electroencephalographical variables decreased significantly after bolus, but a specific pattern in electroencephalographical variables before drug administration was not identified. The same was true for opiate administration. At both 30 minutes and 2 minutes before intratracheal suctioning, there was no difference in electroencephalographical or clinical signs in patients who had or had not received drugs 10 minutes before suctioning. Among patients who received drugs, electroencephalographical parameters returned to baseline more rapidly. In those cases in which Ramsay score was assessed before the event, processed electroencephalography exhibited high variation. Conclusions Unpleasant or painful stimuli and sedative and analgesic drugs are associated with significant changes in processed electroencephalographical parameters. However, clinical indications for drug administration were not reflected by these electroencephalographical parameters, and barely by sedation level before drug administration or tracheal suction. This precludes incorporation of entropy and bispectral index as target variables for sedation and analgesia protocols in critically ill patients.
Collapse
Affiliation(s)
- Matthias Haenggi
- Department of Intensive Care Medicine, Bern University Hospital and University of Bern, Freiburgstrasse, CH-3010 Bern, Switzerland
| | | | | | | | | | | | | |
Collapse
|
43
|
Radhakrishnan M, Kumar S, Jaganath A, Umamaheswara Rao GS. Acute beta-adrenergic blockade: an unusual cause of suppression of spectral entropy values during isoflurane anaesthesia. Acta Anaesthesiol Scand 2008; 52:718-9. [PMID: 18419728 DOI: 10.1111/j.1399-6576.2008.01610.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
44
|
Guerrero JJ, Alsina E, Del Blanco B, Matute E. [Clinical utility of the bispectral index for detecting epileptic seizures]. REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION 2008; 55:127-128. [PMID: 18383980 DOI: 10.1016/s0034-9356(08)70525-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
|
45
|
Shin YC, Kim SI, Ok SY, Kim SC. The Influence of a Muscle Relaxant on Bispectral Index during the Propofol Induction of Anesthesia. Korean J Anesthesiol 2008. [DOI: 10.4097/kjae.2008.54.4.373] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Affiliation(s)
- Yun Chul Shin
- Department of Anesthesiology and Pain Medicine, Soonchunhyang University College of Medicine, Seoul, Korea
| | - Soon Im Kim
- Department of Anesthesiology and Pain Medicine, Soonchunhyang University College of Medicine, Seoul, Korea
| | - Si Young Ok
- Department of Anesthesiology and Pain Medicine, Soonchunhyang University College of Medicine, Seoul, Korea
| | - Sun Chong Kim
- Department of Anesthesiology and Pain Medicine, Soonchunhyang University College of Medicine, Seoul, Korea
| |
Collapse
|
46
|
Choi BM, Yang CS, Woo DH, Koo MS, Kim SH, Lee MA, Kwak HS, Noh GJ. Approximate entropy as the measurement of the electroencephalographic effect during sevoflurane induction. Korean J Anesthesiol 2008. [DOI: 10.4097/kjae.2008.55.4.404] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Affiliation(s)
- Byung Moon Choi
- Department of Anesthesiology and Pain Medicine, National Medical Center, Korea
| | - Cheol Sueng Yang
- Department of Anesthesiology and Pain Medicine, National Medical Center, Korea
| | - Dong Hee Woo
- Department of Anesthesiology and Pain Medicine, National Medical Center, Korea
| | - Min Seok Koo
- Department of Anesthesiology and Pain Medicine, National Medical Center, Korea
| | - Sang Ho Kim
- Department of Anesthesiology and Pain Medicine, Soonchunhyang University Hospital, Soonchunhyang University College of Medicine, Korea
| | - Myung Ae Lee
- Department of Anesthesiology and Pain Medicine, National Medical Center, Korea
| | - Ho Sung Kwak
- Department of Anesthesiology and Pain Medicine, National Medical Center, Korea
| | - Gyu Jeong Noh
- Department of Clinical Pharmacology and Therapeutics, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
- Department of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| |
Collapse
|
47
|
Weil G, Passot S, Servin F, Billard V. Does Spectral Entropy Reflect the Response to Intubation or Incision During Propofol-Remifentanil Anesthesia? Anesth Analg 2008; 106:152-9, table of contents. [DOI: 10.1213/01.ane.0000296454.00236.fc] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
48
|
Panousis P, Heller AR, Burghardt M, Bleyl JU, Koch T. The effects of electromyographic activity on the accuracy of the Narcotrend monitor compared with the Bispectral Index during combined anaesthesia. Anaesthesia 2007; 62:868-74. [PMID: 17697211 DOI: 10.1111/j.1365-2044.2007.05145.x] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
The Narcotrend is a monitor system for the assessment of depth of anaesthesia. The objective of this trial was to investigate the susceptibility of the Narcotrend to electromyographic (EMG) activity when compared with the Bispectral Index (BIS). We enrolled 33 patients undergoing major urological procedures under combined anaesthesia (thoracic epidural analgesia and general anaesthesia). Anaesthetic depth was assessed simultaneously by the BIS XP and Narcotrend. The intended anaesthetic depth ranged between 40 and 55 in the BIS and between D2 and D0 in the Narcotrend. BIS, but not Narcotrend, values correlated significantly (p < 0.0001) with EMG. BIS values between 70 and 80 occurred intermittently above an EMG activity of 35 dB, whereas the Narcotrend and the clinical signs remained unchanged during the period of elevated BIS values. None of the patients reported intra-operative awareness. Increased electromyographic activity does not affect Narcotrend values. Under combined anaesthesia, the Narcotrend monitor is more reliable when compared with the BIS regarding susceptibility to increased EMG activity.
Collapse
Affiliation(s)
- P Panousis
- Department of Anaesthesiology and Intensive Care Therapy, University Hospital, Fetscherstr. 74, 01307 Dresden, Germany.
| | | | | | | | | |
Collapse
|
49
|
Ekman A, Stålberg E, Sundman E, Eriksson LI, Brudin L, Sandin R. The Effect of Neuromuscular Block and Noxious Stimulation on Hypnosis Monitoring During Sevoflurane Anesthesia. Anesth Analg 2007; 105:688-95. [PMID: 17717224 DOI: 10.1213/01.ane.0000278117.31134.34] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
BACKGROUND There are conflicting results on the influence of neuromuscular block (NMB) on the bispectral index (BIS). We investigated the influence of two degrees of NMB on BIS, Alaris auditory-evoked potential index (AAI), and the electromyogram (EMG) obtained with needle electrodes from the frontal and temporal muscles, immediately adjacent to the BIS-sensor. METHODS Twenty patients were anesthetized with sevoflurane, titrated for 30 min to an end-tidal concentration of 1.2% (baseline). Rocuronium was infused to 50% (partial) and 95% (profound) depression of the first twitch in a train-of-four response, the order being randomly chosen. Noxious tetanic electrical stimulation was applied at four occasions: 1) at baseline (control measurement), 2 and 3) at each degree of NMB, and 4) after neostigmine reversal. BIS, AAI, and EMG were obtained 2 min before and 2 min after each noxious stimulation. RESULTS Median BIS and AAI at baseline were 44 (39-50) and 15 (14-16), respectively. The two degrees of NMB did not affect BIS, AAI, and EMG before noxious stimulation. In contrast, profound NMB altered the BIS and AAI responses to noxious stimulation when compared with partial NMB, (BIS P = 0.01, AAI P < 0.01), after neostigmine reversal (BIS P < 0.01, AAI P = 0.01) and compared with baseline (BIS P = 0.08, AAI P = 0.02). No significant increase in EMG was found. CONCLUSION BIS and AAI responses to noxious tetanic electrical stimulation are affected by the degree of NMB during sevoflurane anesthesia whereas NMB does not affect BIS or AAI in the absence of noxious stimulation.
Collapse
Affiliation(s)
- Andreas Ekman
- Department of Physiology and Pharmacology, Section for Anesthesiology and Intensive Care Medicine, Karolinska Institute, Stockholm, Sweden.
| | | | | | | | | | | |
Collapse
|
50
|
Bonhomme V, Hans P. Muscle relaxation and depth of anaesthesia: where is the missing link? Br J Anaesth 2007; 99:456-60. [PMID: 17704524 DOI: 10.1093/bja/aem243] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
|