1
|
Henry EC, Mahvash A, Lopez BP, Kappadath SC. A comparison of methods for in vivo activity and absorbed dose quantification with PET/CT following yttrium-90 radioembolization. Med Phys 2024. [PMID: 38772046 DOI: 10.1002/mp.17174] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Revised: 05/02/2024] [Accepted: 05/07/2024] [Indexed: 05/23/2024] Open
Abstract
BACKGROUND Yttrium-90 (90Y) positron emission tomography (PET)/computed tomography (CT) imaging is increasingly being used to perform tumor (T) and normal liver (NL) voxel dosimetry after 90Y-radioembolization (90Y-RE). Yet, the accuracy of in vivo 90Y-PET/CT imaging, subject to motion blur and co-registration inaccuracies, and 90Y-PET/CT dose quantification, subject to availability of different voxel dosimetry algorithms, are not well understood. PURPOSE The purpose of this study was to investigate the accuracy of 90Y-PET/CT-based activity estimates following 90Y-RE and characterize differences between 90Y-PET/CT-based voxel dosimetry algorithms. METHODS Thirty-five patients underwent 90Y-PET/CT imaging after 90Y-RE with TheraSphere. The net administered 90Y activity (Aadmin) was determined using a dose calibrator and pre- and post-procedure exposure rate measurements. The summation of image-based activity (Aimage) was extracted from perfused volume (PV) and 3D-isotropically 2-cm expanded PV contour (PV+2 cm). Absorbed doses were calculated using voxel S-value (VSV), local deposition method (LDM), and LDM with known activity (LDMKA) dosimetry algorithms. Linear regression and Bland-Altman analysis quantified the relationship between Aimage and Aadmin and between mean dose estimates (DLDM, DVSV, DLDM-KA) for PV, T, and perfused NL volumes. RESULTS While Aadmin and Aimage in PV were highly correlated (R2 > 0.95), the mean bias ± standard error (SE) and (95% limits of agreement, LOA) was significantly non-zero with -22.7 ± 4.7% (± 28.4%). In PV+2 cm, the mean bias ± SE (± LOA) decreased to 1.3 ± 3.4% (± 18.0%) consistent with zero mean error. DLDM and DVSV were highly correlated (R2 > 0.99) for all volumes of interest (VOIs) and the mean bias ± SE (± LOA) was 2.2 ± 0.2% (± 1.0%), 0.7 ± 0.4% (± 2.8%), and 3.2 ± 0.5% (± 2.8%) for PV, T, and NL, respectively. DLDM-KA and DVSV were correlated with R2 = 0.86, 0.80, and 0.86 for PV, T, and NL, respectively. The mean bias ± SE (± LOA) between DLDM-KA and DVSV was significantly non-zero with -19.6 ± 5.1% (± 31.0%), -20.8 ± 4.4% (± 29.0%), and -18.1 ± 5.3% (± 31.1%) for PV, T, and NL, respectively. CONCLUSIONS The summation of Aimage in PV was underestimated relative to Aadmin. Only by accounting for respiratory motion, limited spatial resolution, and PET/CT co-registration errors through VOI expansion was Aimage, on average, equal to Aadmin. The differences between DLDM and DVSV were not clinically relevant, though DLDM-KA was approximately 20% greater than DVSV. Given the high quantitative accuracy of dose calibrators and challenges associated with accurate 90Y-PET/CT quantification, LDMKA is the preferred algorithm for accurate 90Y-PET/CT-based dosimetry following 90Y-RE.
Collapse
Affiliation(s)
- Eric Courtney Henry
- Department of Imaging Physics, University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Armeen Mahvash
- Department of Interventional Radiology, University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Benjamin P Lopez
- Department of Imaging Physics, University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | | |
Collapse
|
2
|
Wise PA, Preukschas AA, Özmen E, Bellemann N, Norajitra T, Sommer CM, Stock C, Mehrabi A, Müller-Stich BP, Kenngott HG, Nickel F. Intraoperative liver deformation and organ motion caused by ventilation, laparotomy, and pneumoperitoneum in a porcine model for image-guided liver surgery. Surg Endosc 2024; 38:1379-1389. [PMID: 38148403 PMCID: PMC10881715 DOI: 10.1007/s00464-023-10612-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Accepted: 11/26/2023] [Indexed: 12/28/2023]
Abstract
BACKGROUND Image-guidance promises to make complex situations in liver interventions safer. Clinical success is limited by intraoperative organ motion due to ventilation and surgical manipulation. The aim was to assess influence of different ventilatory and operative states on liver motion in an experimental model. METHODS Liver motion due to ventilation (expiration, middle, and full inspiration) and operative state (native, laparotomy, and pneumoperitoneum) was assessed in a live porcine model (n = 10). Computed tomography (CT)-scans were taken for each pig for each possible combination of factors. Liver motion was measured by the vectors between predefined landmarks along the hepatic vein tree between CT scans after image segmentation. RESULTS Liver position changed significantly with ventilation. Peripheral regions of the liver showed significantly higher motion (maximal Euclidean motion 17.9 ± 2.7 mm) than central regions (maximal Euclidean motion 12.6 ± 2.1 mm, p < 0.001) across all operative states. The total average motion measured 11.6 ± 0.7 mm (p < 0.001). Between the operative states, the position of the liver changed the most from native state to pneumoperitoneum (14.6 ± 0.9 mm, p < 0.001). From native state to laparotomy comparatively, the displacement averaged 9.8 ± 1.2 mm (p < 0.001). With pneumoperitoneum, the breath-dependent liver motion was significantly reduced when compared to other modalities. Liver motion due to ventilation was 7.7 ± 0.6 mm during pneumoperitoneum, 13.9 ± 1.1 mm with laparotomy, and 13.5 ± 1.4 mm in the native state (p < 0.001 in all cases). CONCLUSIONS Ventilation and application of pneumoperitoneum caused significant changes in liver position. Liver motion was reduced but clearly measurable during pneumoperitoneum. Intraoperative guidance/navigation systems should therefore account for ventilation and intraoperative changes of liver position and peripheral deformation.
Collapse
Affiliation(s)
- Philipp A Wise
- Department of General, Visceral and Transplantation Surgery, Heidelberg University, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany
| | - Anas A Preukschas
- Department of General, Visceral and Transplantation Surgery, Heidelberg University, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany
- Department of General, Visceral and Thoracic Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Germany
| | - Emre Özmen
- Department of General, Visceral and Transplantation Surgery, Heidelberg University, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany
| | - Nadine Bellemann
- Department of Diagnostic and Interventional Radiology, Heidelberg University, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany
| | - Tobias Norajitra
- Division of Medical and Biological Informatics, German Cancer Research Center, Im Neuenheimer Feld 280, 69120, Heidelberg, Germany
| | - Christof M Sommer
- Department of Diagnostic and Interventional Radiology, Heidelberg University, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany
| | - Christian Stock
- Institute for Medical Biometry and Informatics, Heidelberg University, Im Neuenheimer Feld 305, 69120, Heidelberg, Germany
| | - Arianeb Mehrabi
- Department of General, Visceral and Transplantation Surgery, Heidelberg University, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany
| | - Beat P Müller-Stich
- Division of Abdominal Surgery, Clarunis-Academic Centre of Gastrointestinal Diseases, St. Clara and University Hospital of Basel, Petersgraben 4, 4051, Basel, Switzerland
| | - Hannes G Kenngott
- Department of General, Visceral and Transplantation Surgery, Heidelberg University, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany
| | - Felix Nickel
- Department of General, Visceral and Transplantation Surgery, Heidelberg University, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany.
- Department of General, Visceral and Thoracic Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Germany.
| |
Collapse
|
3
|
Tabotta F, Gnesin S, Dunet V, Ponti A, Digklia A, Boughdad S, Schaefer N, Prior JO, Villard N, Tsoumakidou G, Denys A, Duran R. 99mTc-macroaggregated albumin SPECT/CT predictive dosimetry and dose-response relationship in uveal melanoma liver metastases treated with first-line selective internal radiation therapy. Sci Rep 2023; 13:13118. [PMID: 37573346 PMCID: PMC10423257 DOI: 10.1038/s41598-023-39994-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Accepted: 08/03/2023] [Indexed: 08/14/2023] Open
Abstract
First-line selective internal radiation therapy (SIRT) showed promising outcomes in patients with uveal melanoma liver metastases (UMLM). Patient survival depends on liver's disease control. SIRT planning is essential and little is known about dosimetry. We investigated whether 99mTc-MAA-SPECT/CT dosimetry could predict absorbed doses (AD) evaluated on 90Y-PET/CT and assess the dose-response relationship in UMLM patients treated with first-line SIRT. This IRB-approved, single-center, retrospective analysis (prospectively collected cohort) included 12 patients (median age 63y, range 43-82). Patients underwent MRI/CT, 18F-FDG-PET/CT before and 3-6 months post-SIRT, and 90Y-PET/CT immediately post-SIRT. Thirty-two target lesions were included. AD estimates in tumor and non-tumor liver were obtained from 99mTc-MAA-SPECT/CT and post-SIRT 90Y-PET/CT, and assessed with Lin's concordance correlation coefficients (ρc and Cb), Pearson's coefficient correlation (ρ), and Bland-Altman analyses (mean difference ± standard deviation; 95% limits-of-agreement (LOA)). Influence of tumor characteristics and microsphere type on AD was analyzed. Tumor response was assessed according to size-based, enhancement-based and metabolic response criteria. Mean target lesion AD was 349 Gy (range 46-1586 Gy). Concordance between 99mTc-MAA-SPECT/CT and 90Y-PET/CT tumor dosimetry improved upon dose correction for the recovery coefficient (RC) (ρ = 0.725, ρc = 0.703, Cb = 0.969) with good agreement (mean difference: - 4.93 ± 218.3 Gy, 95%LOA: - 432.8-422.9). Without RC correction, concordance was better for resin microspheres (ρ = 0.85, ρc = 0.998, Cb = 0.849) and agreement was very good between predictive 99mTc-MAA-SPECT/CT and 90Y-PET/CT dosimetry (mean difference: - 4.05 ± 55.9 Gy; 95%LOA: - 113.7-105.6). After RC correction, 99mTc-MAA-SPECT/CT dosimetry overestimated AD (- 70.9 ± 158.9 Gy; 95%LOA: - 382.3-240.6). For glass microspheres, concordance markedly improved with RC correction (ρ = 0.790, ρc = 0.713, Cb = 0.903 vs without correction: ρ = 0.395, ρc = 0.244, Cb = 0.617) and 99mTc-MAA-SPECT/CT dosimetry underestimated AD (148.9 ± 267.5 Gy; 95%LOA: - 375.4-673.2). For non-tumor liver, concordance was good between 99mTc-MAA-SPECT/CT and 90Y-PET/CT dosimetry (ρ = 0.942, ρc = 0.852, Cb = 0.904). 99mTc-MAA-SPECT/CT slightly overestimated liver AD for resin (3.4 ± 3.4 Gy) and glass (11.5 ± 13.9 Gy) microspheres. Tumor AD was not correlated with baseline or post-SIRT lesion characteristics and no dose-response threshold could be identified. 99mTc-MAA-SPECT/CT dosimetry provides good estimates of AD to tumor and non-tumor liver in UMLM patients treated with first-line SIRT.
Collapse
Affiliation(s)
- Flavian Tabotta
- Department of Radiology and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Silvano Gnesin
- Institute of Radiation Physics, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
- Department of Nuclear Medicine and Molecular Imaging, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Vincent Dunet
- Department of Radiology and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Alexandre Ponti
- Department of Radiology and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Antonia Digklia
- Department of Medical Oncology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Sarah Boughdad
- Department of Nuclear Medicine and Molecular Imaging, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Niklaus Schaefer
- Department of Nuclear Medicine and Molecular Imaging, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - John O Prior
- Department of Nuclear Medicine and Molecular Imaging, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Nicolas Villard
- Department of Radiology and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Georgia Tsoumakidou
- Department of Radiology and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Alban Denys
- Department of Radiology and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Rafael Duran
- Department of Radiology and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
| |
Collapse
|
4
|
Salih T, Elgie L, Hari B, Williams B, Thomas RM, Bandula S, Walkden M, Sultan P, McPherson K, Jenkins K. In-Circuit High-Frequency Jet Ventilation for Radiological Tumor Ablation: A Case Series. A A Pract 2022; 16:e01608. [DOI: 10.1213/xaa.0000000000001608] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
5
|
Musa M, Sengupta S, Chen Y. Design of a 6-DoF Parallel Robotic Platform for MRI Applications. JOURNAL OF MEDICAL ROBOTICS RESEARCH 2022; 7:2241005. [PMID: 37614779 PMCID: PMC10445425 DOI: 10.1142/s2424905x22410057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/25/2023]
Abstract
In this work, the design, analysis, and characterization of a parallel robotic motion generation platform with 6-degrees of freedom (DoF) for magnetic resonance imaging (MRI) applications are presented. The motivation for the development of this robot is the need for a robotic platform able to produce accurate 6-DoF motion inside the MRI bore to serve as the ground truth for motion modeling; other applications include manipulation of interventional tools such as biopsy and ablation needles and ultrasound probes for therapy and neuromodulation under MRI guidance. The robot is comprised of six pneumatic cylinder actuators controlled via a robust sliding mode controller. Tracking experiments of the pneumatic actuator indicates that the system is able to achieve an average error of 0.69 ± 0.14 mm and 0.67 ± 0.40 mm for step signal tracking and sinusoidal signal tracking, respectively. To demonstrate the feasibility and potential of using the proposed robot for minimally invasive procedures, a phantom experiment was performed in the benchtop environment, which showed a mean positional error of 1.20 ± 0.43 mm and a mean orientational error of 1.09 ± 0.57°, respectively. Experiments conducted in a 3T whole body human MRI scanner indicate that the robot is MRI compatible and capable of achieving positional error of 1.68 ± 0.31 mm and orientational error of 1.51 ± 0.32° inside the scanner, respectively. This study demonstrates the potential of this device to enable accurate 6-DoF motions in the MRI environment.
Collapse
Affiliation(s)
- Mishek Musa
- Department of Mechanical Engineering, University of Arkansas, Fayetteville, AR 72701, USA
| | - Saikat Sengupta
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN 37232, USA
| | - Yue Chen
- Department of Biomedical Engineering, Georgia Institute of Technology/Emory University, Atlanta, GA 30332, USA
| |
Collapse
|
6
|
de Baere T, Roux C, Noel G, Delpla A, Deschamps F, Varin E, Tselikas L. Robotic assistance for percutaneous needle insertion in the kidney: preclinical proof on a swine animal model. Eur Radiol Exp 2022; 6:13. [PMID: 35257224 PMCID: PMC8901810 DOI: 10.1186/s41747-022-00265-1] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Accepted: 01/17/2022] [Indexed: 01/04/2023] Open
Abstract
Abstract
Background
We evaluated the accuracy, safety, and feasibility of a computed tomography (CT)-guided robotic assistance system for percutaneous needle placement in the kidney.
Methods
Fiducials surgically implanted into the kidneys of two pigs were used as targets for subsequent robotically-assisted needle insertion. Robotically-assisted needle insertions and CT acquisitions were coordinated using respiratory monitoring. An initial scan volume data set was used for needle insertion planning defining skin entry and target point. Then, needle insertion was performed according to robot positioning. The accuracy of needle placement was evaluated upon the distance between the needle tip and the predefined target on a post needle insertion scan. A delayed contrast-enhanced CT scan was acquired to assess safety.
Results
Eight needle trajectories were performed with a median procedural time measured from turning on the robotic system to post needle insertion CT scan of 21 min (interquartile range 15.5−26.5 min). Blind review of needle placement accuracy was 2.3 ± 1.2 mm (mean ± standard deviation) in lateral deviation, 0.7 ± 1.7 mm in depth deviation, and 2.8 ± 1.3 mm in three-dimensional Euclidian deviation. All needles were inserted on the first attempt, which determined 100% feasibility, without needle readjustment. The angulation and length of the trajectory did not impact on the needle placement accuracy. Two minor procedure-related complications were encountered: 2 subcapsular haematomas (13 × 6 mm and 35 × 6 mm) in the same animal.
Conclusions
Robotically-assisted needle insertion was shown feasible, safe and accurate in a swine kidney model. Further larger studies are needed.
Collapse
|
7
|
Dong G, Zhang C, Deng L, Zhu Y, Dai J, Song L, Meng R, Niu T, Liang X, Xie Y. A deep unsupervised learning framework for the 4D CBCT artifact correction. Phys Med Biol 2022; 67. [DOI: 10.1088/1361-6560/ac55a5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Accepted: 02/16/2022] [Indexed: 11/11/2022]
Abstract
Abstract
Objective. Four-dimensional cone-beam computed tomography (4D CBCT) has unique advantages in moving target localization, tracking and therapeutic dose accumulation in adaptive radiotherapy. However, the severe fringe artifacts and noise degradation caused by 4D CBCT reconstruction restrict its clinical application. We propose a novel deep unsupervised learning model to generate the high-quality 4D CBCT from the poor-quality 4D CBCT. Approach. The proposed model uses a contrastive loss function to preserve the anatomical structure in the corrected image. To preserve the relationship between the input and output image, we use a multilayer, patch-based method rather than operate on entire images. Furthermore, we draw negatives from within the input 4D CBCT rather than from the rest of the dataset. Main results. The results showed that the streak and motion artifacts were significantly suppressed. The spatial resolution of the pulmonary vessels and microstructure were also improved. To demonstrate the results in the different directions, we make the animation to show the different views of the predicted correction image in the supplementary animation. Significance. The proposed method can be integrated into any 4D CBCT reconstruction method and maybe a practical way to enhance the image quality of the 4D CBCT.
Collapse
|
8
|
Zhang W, Xia P, Liu S, Huang X, Zhao X, Liu Z, Dang H, Li X, Niu G. A coordinate positioning puncture method under robot-assisted CT-guidance: phantom and animal experiments. MINIM INVASIV THER 2022; 31:206-215. [PMID: 32633586 DOI: 10.1080/13645706.2020.1787451] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
PURPOSE To evaluate the accuracy of the robot-assisted computed tomography (CT)-guided coordinate positioning puncture method by phantom and animal experiments. MATERIAL AND METHODS In the phantom experiment, seven robot-assisted punctures were made to evaluate the accuracy of the method. In the animal experiment, 18 punctures (nine robotic and nine manual) were made in the livers of nine rabbits. The indicators, such as needle-tract length, angle deviation, puncture accuracy, number of scans required, and radiation exposure dose were compared between manual and robotic punctures. The paired-samples t-test was used for analysis. RESULTS In the phantom experiment, the mean accuracy of seven punctures was 2.67 mm. In the animal experiment, there was no significant difference in needle-tract length (32.58 mm vs. 34.04 mm, p = .606), angle deviation (17.21° vs. 21.23° p = .557) and puncture accuracy (8.42 vs. 8.77 mm, p = .851) between the two groups. However, the number CT scans required (2.44 vs. 3.33, p = .002), and the radiation exposure dose (772.98 vs. 1077.89 mGy/cm, p = .003) were lower in the robot group than in the manual group. CONCLUSIONS The coordinate positioning puncture method under robot-assisted CT-guidance can reach an accuracy that is comparable to that of the traditional manual CT-guided puncture method and with fewer CT scanning times accompanied with a lower radiation dosage.
Collapse
Affiliation(s)
- Weifan Zhang
- Department of Surgical Oncology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, PR China
| | - Peng Xia
- Department of Surgical Oncology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, PR China
| | - Shijie Liu
- School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, PR China
| | - Xiaowei Huang
- School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, PR China
| | - Xinhui Zhao
- Department of Surgical Oncology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, PR China
| | - Zhao Liu
- Department of Surgical Oncology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, PR China
| | - Hui Dang
- Department of Endocrinology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, PR China
| | - Xiaohu Li
- School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, PR China
| | - Gang Niu
- Department of Medical Imaging, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, PR China
| |
Collapse
|
9
|
Effects of Respiratory Motion on Y-90 PET Dosimetry for SIRT. Diagnostics (Basel) 2022; 12:diagnostics12010194. [PMID: 35054361 PMCID: PMC8775032 DOI: 10.3390/diagnostics12010194] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Revised: 01/07/2022] [Accepted: 01/10/2022] [Indexed: 12/04/2022] Open
Abstract
Respiratory motion degrades the quantification accuracy of PET imaging by blurring the radioactivity distribution. In the case of post-SIRT PET-CT verification imaging, respiratory motion can lead to inaccuracies in dosimetric measures. Using an anthropomorphic phantom filled with 90Y at a range of clinically relevant activities, together with a respiratory motion platform performing realistic motions (10–15 mm amplitude), we assessed the impact of respiratory motion on PET-derived post-SIRT dosimetry. Two PET scanners at two sites were included in the assessment. The phantom experiments showed that device-driven quiescent period respiratory motion correction improved the accuracy of the quantification with statistically significant increases in both the mean contrast recovery (+5%, p = 0.003) and the threshold activities corresponding to the dose to 80% of the volume of interest (+6%, p < 0.001). Although quiescent period gating also reduces the number of counts and hence increases the noise in the PET image, its use is encouraged where accurate quantification of the above metrics is desired.
Collapse
|
10
|
Kyme AZ, Fulton RR. Motion estimation and correction in SPECT, PET and CT. Phys Med Biol 2021; 66. [PMID: 34102630 DOI: 10.1088/1361-6560/ac093b] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Accepted: 06/08/2021] [Indexed: 11/11/2022]
Abstract
Patient motion impacts single photon emission computed tomography (SPECT), positron emission tomography (PET) and X-ray computed tomography (CT) by giving rise to projection data inconsistencies that can manifest as reconstruction artifacts, thereby degrading image quality and compromising accurate image interpretation and quantification. Methods to estimate and correct for patient motion in SPECT, PET and CT have attracted considerable research effort over several decades. The aims of this effort have been two-fold: to estimate relevant motion fields characterizing the various forms of voluntary and involuntary motion; and to apply these motion fields within a modified reconstruction framework to obtain motion-corrected images. The aims of this review are to outline the motion problem in medical imaging and to critically review published methods for estimating and correcting for the relevant motion fields in clinical and preclinical SPECT, PET and CT. Despite many similarities in how motion is handled between these modalities, utility and applications vary based on differences in temporal and spatial resolution. Technical feasibility has been demonstrated in each modality for both rigid and non-rigid motion, but clinical feasibility remains an important target. There is considerable scope for further developments in motion estimation and correction, and particularly in data-driven methods that will aid clinical utility. State-of-the-art machine learning methods may have a unique role to play in this context.
Collapse
Affiliation(s)
- Andre Z Kyme
- School of Biomedical Engineering, The University of Sydney, Sydney, New South Wales, AUSTRALIA
| | - Roger R Fulton
- Sydney School of Health Sciences, The University of Sydney, Sydney, New South Wales, AUSTRALIA
| |
Collapse
|
11
|
Catheter navigation support for liver radioembolization guidance: feasibility of structure-driven intensity-based registration. Int J Comput Assist Radiol Surg 2020; 15:1881-1894. [PMID: 32870445 DOI: 10.1007/s11548-020-02250-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Accepted: 08/16/2020] [Indexed: 10/23/2022]
Abstract
PURPOSE The fusion of pre/intraoperative images may improve catheter manipulation during radioembolization (RE) interventions by adding relevant information. The objective of this work is to propose and evaluate the performance of a RE guidance strategy relying on structure-driven intensity-based registration between preoperative CTA and intraoperative X-ray images. METHODS The navigation strategy is decomposed into three image fusion steps, supporting the catheter navigation from the femoral artery till reaching the injection site (IS). During the pretreatment assessment intervention, the aorta and the origins of its side branches are projected on the intraoperative 2D fluoroscopy following a 3D/2D bone-based registration process, to assist the celiac trunk access. Subsequently, a similar approach consisting in projecting the hepatic vasculature on intraoperative DSA through 3D/2D vessel-based registration is performed to assist the IS location. Lastly, the selected IS is reproduced during the treatment intervention by employing 2D/2D image-based registration between pretreatment and treatment fluoroscopic images. RESULTS The three fusion steps were independently evaluated on subsets of 20, 19 and 5 patient cases, respectively. Best results were obtained with gradient difference as similarity measure and with a delimited preoperative vascular structure for vessel-based registration. The approach resulted in qualitatively appropriate anatomical correspondences when projecting the preoperative structures on intraoperative images. With the best configuration, the registration steps showed accuracy and feasibility in aligning data, with global mean landmarks errors of 1.59 mm, 2.32 mm and 2.17 mm, respectively, a computation time that never exceeded 5 s, 25 s and 11 s, respectively, and a user interaction limited to manual initialization of the 3D/2D registration. CONCLUSION An image fusion-based approach has been specifically proposed for RE procedures guidance. The catheter manipulation strategy based on the fusion of pre- and intraoperative images has the potential to support different steps of the RE clinical workflow and to guide the overall procedure.
Collapse
|
12
|
Real-time control of respiratory motion: Beyond radiation therapy. Phys Med 2019; 66:104-112. [PMID: 31586767 DOI: 10.1016/j.ejmp.2019.09.241] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/23/2019] [Revised: 09/23/2019] [Accepted: 09/26/2019] [Indexed: 12/16/2022] Open
Abstract
Motion management in radiation oncology is an important aspect of modern treatment planning and delivery. Special attention has been paid to control respiratory motion in recent years. However, other medical procedures related to both diagnosis and treatment are likely to benefit from the explicit control of breathing motion. Quantitative imaging - including increasingly important tools in radiology and nuclear medicine - is among the fields where a rapid development of motion control is most likely, due to the need for quantification accuracy. Emerging treatment modalities like focussed-ultrasound tumor ablation are also likely to benefit from a significant evolution of motion control in the near future. In the present article an overview of available respiratory motion systems along with ongoing research in this area is provided. Furthermore, an attempt is made to envision some of the most expected developments in this field in the near future.
Collapse
|
13
|
Liu M, Cygler JE, Vandervoort E. Geometrical tracking accuracy and appropriate PTV margins for robotic radiosurgery of liver lesions by SBRT. Acta Oncol 2019; 58:906-915. [PMID: 30799669 DOI: 10.1080/0284186x.2019.1578896] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Purpose: To assess the geometrical accuracy and estimate adequate PTV margins for liver treatments using the Synchrony respiratory tracking system. Material and methods: Treatment log files are analyzed for 72 liver patients to assess tracking accuracy. The tracking error is calculated as the quadratic sum of the correlation, the predictor and the beam positioning errors. Treatment target rotations and rigid body errors reported by the system are also evaluated. The impact of uncorrected rotations is assessed by rotating the planned dose distribution and reassessing target coverage. Total PTV margins are estimated by summing in quadrature tracking errors and rigid body errors. Relationships are explored between tracking errors, model linearity and motion amplitudes of internal and external markers. Results: Margins of 3, 2, 2 mm in SUP-INF, LT-RT and ANT-POST directions, respectively, are sufficient to account for tracking and beam positioning errors for 95% of patients. If rigid body error is also considered, margins increase to 4 mm isotropic. Rotations could not be corrected for 92% of patients due to imperfect fiducial implantation and limitations in the magnitude of corrections that the system can apply. Uncorrected rotations would lead to average estimated dose reductions of 2.7% ± 5.8% of the prescribed dose for D99 of GTVs (5 mm PTV expansion) in which the target was well covered in the original plan (28 of 31 GTVs). 80% of tracking models exhibit near linear correlation between internal and external marker motions with small tracking errors (<2.2 mm). Conclusions: Isotropic PTV margins considering tracking errors and target rigid body errors could be used for liver SBRT treatments if rotational corrections can be calculated accurately so that systematic rotational offsets can be avoided. The linearity of the internal and external breathing motions might be useful for other types of treatment modalities for liver cancer.
Collapse
Affiliation(s)
- Ming Liu
- Department of Physics, Carleton University, Ottawa, Canada
| | - Joanna E. Cygler
- Department of Physics, Carleton University, Ottawa, Canada
- Department of Medical Physics, The Ottawa Hospital Cancer Centre, Ottawa, Canada
- Department of Radiology, University of Ottawa, Ottawa, Canada
| | - Eric Vandervoort
- Department of Physics, Carleton University, Ottawa, Canada
- Department of Medical Physics, The Ottawa Hospital Cancer Centre, Ottawa, Canada
- Department of Radiology, University of Ottawa, Ottawa, Canada
| |
Collapse
|
14
|
Comparison of End-Expiration Versus End-Inspiration Breath-Holds With Respect to Respiratory Motion Artifacts on T1-Weighted Abdominal MRI. AJR Am J Roentgenol 2019; 212:1024-1029. [PMID: 30835515 DOI: 10.2214/ajr.18.20239] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
OBJECTIVE. The purpose of this study was to compare respiratory motion artifact and diagnostic image quality between end-inspiration and end-expiration breath-holding techniques on unenhanced and contrast-enhanced axial T1-weighted MRI of the liver. MATERIALS AND METHODS. This retrospective observational study included 50 consecutive subjects undergoing axial T1-weighted liver MRI, with unenhanced images acquired with both end-inspiration and end-expiration breath-holding techniques, and with contrast-enhanced images acquired for 47 of the subjects with either the end-inspiration or the end-expiration breath-holding technique. Three radiologists performed blinded independent evaluations of each unenhanced sequence, contrast-enhanced sequence, and subtraction (contrast-enhanced minus unenhanced) image, using a scale ranging from 1 point (denoting nondiagnostic imaging) to 5 points (denoting no artifacts). Blinded side-by-side assessment of each pair of unenhanced sequences was also performed. Two-tailed Wilcoxon signed rank and Wilcoxon rank sum tests were used to assess statistical significance. RESULTS. A significant improvement in motion scores was noted for sequences acquired in end-expiration, compared with those acquired in end-inspiration, for unenhanced sequences (mean, 3.35 vs 2.80; p < 0.00001), contrast-enhanced sequences (mean, 4.02 vs 3.46; p = 0.0003), and subtraction images (mean, 3.67 vs 2.41; p < 0.00001). Severe degradation of image quality or nondiagnostic image quality was noted for 15% of unenhanced images (23/150), 0% of contrast-enhanced images, and 8% (5/63) of subtraction images acquired on end-expiration, whereas it was noted for 36% (54/150) of unenhanced images, 13% (10/78) of contrast-enhanced images, and 59% (46/78) of subtraction images acquired on end-inspiration. When side-by-side assessment of paired unenhanced sequences was performed, images acquired in end-expiration were significantly favored in 59% of paired sequences (88/150) (p < 0.00001), and no difference between images acquired with both breath-hold techniques was noted for 21% (32/150) of paired sequences. CONCLUSION. The end-expiration breath-holding technique leads to significant decreases in respiratory motion artifacts, compared with the end-inspiration technique, on unenhanced and contrast-enhanced T1-weighted liver MRI.
Collapse
|
15
|
Automatic planning of needle placement for robot-assisted percutaneous procedures. Int J Comput Assist Radiol Surg 2018; 13:1429-1438. [PMID: 29671199 DOI: 10.1007/s11548-018-1754-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2018] [Accepted: 03/26/2018] [Indexed: 12/24/2022]
Abstract
PURPOSE Percutaneous procedures allow interventional radiologists to perform diagnoses or treatments guided by an imaging device, typically a computed tomography (CT) scanner with a high spatial resolution. To reduce exposure to radiations and improve accuracy, robotic assistance to needle insertion is considered in the case of X-ray guided procedures. We introduce a planning algorithm that computes a needle placement compatible with both the patient's anatomy and the accessibility of the robot within the scanner gantry. METHODS Our preoperative planning approach is based on inverse kinematics, fast collision detection, and bidirectional rapidly exploring random trees coupled with an efficient strategy of node addition. The algorithm computes the allowed needle entry zones over the patient's skin (accessibility map) from 3D models of the patient's anatomy, the environment (CT, bed), and the robot. The result includes the admissible robot joint path to target the prescribed internal point, through the entry point. A retrospective study was performed on 16 patients datasets in different conditions: without robot (WR) and with the robot on the left or the right side of the bed (RL/RR). RESULTS We provide an accessibility map ensuring a collision-free path of the robot and allowing for a needle placement compatible with the patient's anatomy. The result is obtained in an average time of about 1 min, even in difficult cases. The accessibility maps of RL and RR covered about a half of the surface of WR map in average, which offers a variety of options to insert the needle with the robot. We also measured the average distance between the needle and major obstacles such as the vessels and found that RL and RR produced needle placements almost as safe as WR. CONCLUSION The introduced planning method helped us prove that it is possible to use such a "general purpose" redundant manipulator equipped with a dedicated tool to perform percutaneous interventions in cluttered spaces like a CT gantry.
Collapse
|
16
|
Walker MD, Bradley KM, McGowan DR. Evaluation of principal component analysis-based data-driven respiratory gating for positron emission tomography. Br J Radiol 2018; 91:20170793. [PMID: 29419327 PMCID: PMC5911393 DOI: 10.1259/bjr.20170793] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Objective: Respiratory motion can degrade PET image quality and lead to inaccurate quantification of lesion uptake. Such motion can be mitigated via respiratory gating. Our objective was to evaluate a data-driven gating (DDG) technique that is being developed commercially for clinical PET/CT. Methods: A data-driven respiratory gating algorithm based on principal component analysis (PCA) was applied to phantom and FDG patient data. An anthropomorphic phantom and a NEMA IEC Body phantom were filled with 18F, placed on a respiratory motion platform, and imaged using a PET/CT scanner. Motion waveforms were measured using an infrared camera [the Real-time Position Management™ system (RPM)] and also extracted from the PET data using the DDG algorithm. The waveforms were compared via calculation of Pearson’s correlation coefficients. PET data were reconstructed using quiescent period gating (QPG) and compared via measurement of recovery percentage and background variability. Results: Data-driven gating had similar performance to the external gating system, with correlation coefficients in excess of 0.97. Phantom and patient images were visually clearer with improved contrast when QPG was applied as compared to no motion compensation. Recovery coefficients in the phantoms were not significantly different between DDG- and RPM-based QPG, but were significantly higher than those found for no motion compensation (p < 0.05). Conclusion: A PCA-based DDG algorithm was evaluated and found to provide a reliable respiratory gating signal in anthropomorphic phantom studies and in example patients. Advances in knowledge: The prototype commercial DDG algorithm may enable reliable respiratory gating in routine clinical PET-CT.
Collapse
Affiliation(s)
- Matthew D Walker
- 1 Radiation Physics and Protection, Churchill Hospital, Oxford University Hospitals NHS Foundation Trust , Oxford , UK
| | - Kevin M Bradley
- 2 Department of Radiology, Churchill Hospital, Oxford University Hospitals NHS Foundation Trust , Oxford , UK
| | - Daniel R McGowan
- 1 Radiation Physics and Protection, Churchill Hospital, Oxford University Hospitals NHS Foundation Trust , Oxford , UK.,3 Department of Oncology, University of Oxford , Oxford , UK
| |
Collapse
|
17
|
Ozkan E, Goksel O. Compliance boundary conditions for patient-specific deformation simulation using the finite element method. Biomed Phys Eng Express 2018. [DOI: 10.1088/2057-1976/aa918d] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
18
|
Abayazid M, Kato T, Silverman SG, Hata N. Using needle orientation sensing as surrogate signal for respiratory motion estimation in percutaneous interventions. Int J Comput Assist Radiol Surg 2018; 13:125-133. [PMID: 28766177 PMCID: PMC5754381 DOI: 10.1007/s11548-017-1644-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2017] [Accepted: 07/10/2017] [Indexed: 12/25/2022]
Abstract
PURPOSE To develop and evaluate an approach to estimate the respiratory-induced motion of lesions in the chest and abdomen. MATERIALS AND METHODS The proposed approach uses the motion of an initial reference needle inserted into a moving organ to estimate the lesion (target) displacement that is caused by respiration. The needles position is measured using an inertial measurement unit (IMU) sensor externally attached to the hub of an initially placed reference needle. Data obtained from the IMU sensor and the target motion are used to train a learning-based approach to estimate the position of the moving target. An experimental platform was designed to mimic respiratory motion of the liver. Liver motion profiles of human subjects provided inputs to the experimental platform. Variables including the insertion angle, target depth, target motion velocity and target proximity to the reference needle were evaluated by measuring the error of the estimated target position and processing time. RESULTS The mean error of estimation of the target position ranged between 0.86 and 1.29 mm. The processing maximum training and testing time was 5 ms which is suitable for real-time target motion estimation using the needle position sensor. CONCLUSION The external motion of an initially placed reference needle inserted into a moving organ can be used as a surrogate, measurable and accessible signal to estimate in real-time the position of a moving target caused by respiration; this technique could then be used to guide the placement of subsequently inserted needles directly into the target.
Collapse
Affiliation(s)
- Momen Abayazid
- Department of Radiology, Brigham and Womens Hospital and Harvard Medical School, Boston, MA, USA.
- MIRA-Institute for Biomedical Technology and Technical Medicine (Robotics and Mechatronics), University of Twente, Enschede, The Netherlands.
| | - Takahisa Kato
- Department of Radiology, Brigham and Womens Hospital and Harvard Medical School, Boston, MA, USA
- Healthcare Optics Research Laboratory, Canon U.S.A., Inc., Cambridge, MA, USA
| | - Stuart G Silverman
- Department of Radiology, Brigham and Womens Hospital and Harvard Medical School, Boston, MA, USA
| | - Nobuhiko Hata
- Department of Radiology, Brigham and Womens Hospital and Harvard Medical School, Boston, MA, USA
| |
Collapse
|
19
|
Küstner T, Schwartz M, Martirosian P, Gatidis S, Seith F, Gilliam C, Blu T, Fayad H, Visvikis D, Schick F, Yang B, Schmidt H, Schwenzer NF. MR-based respiratory and cardiac motion correction for PET imaging. Med Image Anal 2017; 42:129-144. [PMID: 28800546 DOI: 10.1016/j.media.2017.08.002] [Citation(s) in RCA: 56] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2017] [Revised: 07/18/2017] [Accepted: 08/01/2017] [Indexed: 01/22/2023]
Abstract
PURPOSE To develop a motion correction for Positron-Emission-Tomography (PET) using simultaneously acquired magnetic-resonance (MR) images within 90 s. METHODS A 90 s MR acquisition allows the generation of a cardiac and respiratory motion model of the body trunk. Thereafter, further diagnostic MR sequences can be recorded during the PET examination without any limitation. To provide full PET scan time coverage, a sensor fusion approach maps external motion signals (respiratory belt, ECG-derived respiration signal) to a complete surrogate signal on which the retrospective data binning is performed. A joint Compressed Sensing reconstruction and motion estimation of the subsampled data provides motion-resolved MR images (respiratory + cardiac). A 1-POINT DIXON method is applied to these MR images to derive a motion-resolved attenuation map. The motion model and the attenuation map are fed to the Customizable and Advanced Software for Tomographic Reconstruction (CASToR) PET reconstruction system in which the motion correction is incorporated. All reconstruction steps are performed online on the scanner via Gadgetron to provide a clinically feasible setup for improved general applicability. The method was evaluated on 36 patients with suspected liver or lung metastasis in terms of lesion quantification (SUVmax, SNR, contrast), delineation (FWHM, slope steepness) and diagnostic confidence level (3-point Likert-scale). RESULTS A motion correction could be conducted for all patients, however, only in 30 patients moving lesions could be observed. For the examined 134 malignant lesions, an average improvement in lesion quantification of 22%, delineation of 64% and diagnostic confidence level of 23% was achieved. CONCLUSION The proposed method provides a clinically feasible setup for respiratory and cardiac motion correction of PET data by simultaneous short-term MRI. The acquisition sequence and all reconstruction steps are publicly available to foster multi-center studies and various motion correction scenarios.
Collapse
Affiliation(s)
- Thomas Küstner
- Institute of Signal Processing and System Theory, University of Stuttgart, Stuttgart, Germany; Department of Radiology, University of Tübingen, Tübingen, Germany.
| | - Martin Schwartz
- Institute of Signal Processing and System Theory, University of Stuttgart, Stuttgart, Germany; Section on Experimental Radiology, University of Tübingen, Germany
| | | | - Sergios Gatidis
- Department of Radiology, University of Tübingen, Tübingen, Germany
| | - Ferdinand Seith
- Department of Radiology, University of Tübingen, Tübingen, Germany
| | - Christopher Gilliam
- Department of Electronic Engineering, Chinese University of Hong Kong, Hong Kong
| | - Thierry Blu
- Department of Electronic Engineering, Chinese University of Hong Kong, Hong Kong
| | - Hadi Fayad
- INSERM U1101, LaTIM, University of Bretagne, Brest, France
| | | | - F Schick
- Section on Experimental Radiology, University of Tübingen, Germany
| | - B Yang
- Institute of Signal Processing and System Theory, University of Stuttgart, Stuttgart, Germany
| | - H Schmidt
- Department of Radiology, University of Tübingen, Tübingen, Germany
| | - N F Schwenzer
- Department of Radiology, University of Tübingen, Tübingen, Germany
| |
Collapse
|
20
|
Oshiro Y, Ohkohchi N. Three-Dimensional Liver Surgery Simulation: Computer-Assisted Surgical Planning with Three-Dimensional Simulation Software and Three-Dimensional Printing<sup/>. Tissue Eng Part A 2017; 23:474-480. [PMID: 28343411 DOI: 10.1089/ten.tea.2016.0528] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
To perform accurate hepatectomy without injury, it is necessary to understand the anatomical relationship among the branches of Glisson's sheath, hepatic veins, and tumor. In Japan, three-dimensional (3D) preoperative simulation for liver surgery is becoming increasingly common, and liver 3D modeling and 3D hepatectomy simulation by 3D analysis software for liver surgery have been covered by universal healthcare insurance since 2012. Herein, we review the history of virtual hepatectomy using computer-assisted surgery (CAS) and our research to date, and we discuss the future prospects of CAS. We have used the SYNAPSE VINCENT medical imaging system (Fujifilm Medical, Tokyo, Japan) for 3D visualization and virtual resection of the liver since 2010. We developed a novel fusion imaging technique combining 3D computed tomography (CT) with magnetic resonance imaging (MRI). The fusion image enables us to easily visualize anatomic relationships among the hepatic arteries, portal veins, bile duct, and tumor in the hepatic hilum. In 2013, we developed an original software, called Liversim, which enables real-time deformation of the liver using physical simulation, and a randomized control trial has recently been conducted to evaluate the use of Liversim and SYNAPSE VINCENT for preoperative simulation and planning. Furthermore, we developed a novel hollow 3D-printed liver model whose surface is covered with frames. This model is useful for safe liver resection, has better visibility, and the production cost is reduced to one-third of a previous model. Preoperative simulation and navigation with CAS in liver resection are expected to help planning and conducting a surgery and surgical education. Thus, a novel CAS system will contribute to not only the performance of reliable hepatectomy but also to surgical education.
Collapse
Affiliation(s)
- Yukio Oshiro
- Division of Gastroenterological and Hepatobiliary Surgery and Organ Transplantation, Department of Surgery, Faculty of Medicine, University of Tsukuba , Tsukuba, Japan
| | - Nobuhiro Ohkohchi
- Division of Gastroenterological and Hepatobiliary Surgery and Organ Transplantation, Department of Surgery, Faculty of Medicine, University of Tsukuba , Tsukuba, Japan
| |
Collapse
|
21
|
James J, Cetnar A, Dunlap NE, Huffaker C, Nguyen VN, Potts M, Wang B. Technical Note: Validation and implementation of a wireless transponder tracking system for gated stereotactic ablative radiotherapy of the liver. Med Phys 2017; 43:2794-2801. [PMID: 27277027 DOI: 10.1118/1.4948669] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Tracking soft-tissue targets has recently been cleared as a new application of Calypso, an electromagnetic wireless transponder tracking system, allowing for gated treatment of the liver based on the motion of the target volume itself. The purpose of this study is to describe the details of validating the Calypso system for wireless transponder tracking of the liver and to present the clinical workflow for using it to deliver gated stereotactic ablative radiotherapy (SABR). METHODS A commercial 3D diode array motion system was used to evaluate the dynamic tracking accuracy of Calypso when tracking continuous large amplitude motion. It was then used to perform end-to-end tests to evaluate the dosimetric accuracy of gated beam delivery for liver SABR. In addition, gating limits were investigated to determine how large the gating window can be while still maintaining dosimetric accuracy. The gating latency of the Calypso system was also measured using a customized motion phantom. RESULTS The average absolute difference between the measured and expected positional offset was 0.3 mm. The 2%/2 mm gamma pass rates for the gated treatment delivery were greater than 97%. When increasing the gating limits beyond the known extent of planned motion, the gamma pass rates decreased as expected. The 2%/2 mm gamma pass rate for a 1, 2, and 3 mm increase in gating limits was measured to be 97.8%, 82.9%, and 61.4%, respectively. The average gating latency was measured to be 63.8 ms for beam-hold and 195.8 ms for beam-on. Four liver patients with 17 total fractions have been successfully treated at our institution. CONCLUSIONS Wireless transponder tracking was validated as a dosimetrically accurate way to provide gated SABR of the liver. The dynamic tracking accuracy of the Calypso system met manufacturer's specification, even for continuous large amplitude motion that can be encountered when tracking liver tumors close to the diaphragm. The measured beam-hold gating latency was appropriate for targets that will traverse the gating limit each respiratory cycle causing the beam to be interrupted constantly throughout treatment delivery.
Collapse
Affiliation(s)
- Joshua James
- Department of Radiation Oncology, University of Louisville, Louisville, Kentucky 40202
| | - Ashley Cetnar
- Department of Radiation Oncology, Ohio State University, Columbus, Ohio 43210
| | - Neal E Dunlap
- Department of Radiation Oncology, University of Louisville, Louisville, Kentucky 40202
| | | | - Vi Nhan Nguyen
- Department of Radiation Oncology, University of Louisville, Louisville, Kentucky 40202
| | - Melissa Potts
- Department of Radiology, University of Louisville, Louisville, Kentucky 40202
| | - Brian Wang
- Department of Radiation Oncology, University of Louisville, Louisville, Kentucky 40202
| |
Collapse
|
22
|
Lee CK, Seo N, Kim B, Huh J, Kim JK, Lee SS, Kim IS, Nickel D, Kim KW. The Effects of Breathing Motion on DCE-MRI Images: Phantom Studies Simulating Respiratory Motion to Compare CAIPIRINHA-VIBE, Radial-VIBE, and Conventional VIBE. Korean J Radiol 2017; 18:289-298. [PMID: 28246509 PMCID: PMC5313517 DOI: 10.3348/kjr.2017.18.2.289] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2016] [Accepted: 10/18/2016] [Indexed: 11/15/2022] Open
Abstract
OBJECTIVE To compare the breathing effects on dynamic contrast-enhanced (DCE)-MRI between controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA)-volumetric interpolated breath-hold examination (VIBE), radial VIBE with k-space-weighted image contrast view-sharing (radial-VIBE), and conventional VIBE (c-VIBE) sequences using a dedicated phantom experiment. MATERIALS AND METHODS We developed a moving platform to simulate breathing motion. We conducted dynamic scanning on a 3T machine (MAGNETOM Skyra, Siemens Healthcare) using CAIPIRINHA-VIBE, radial-VIBE, and c-VIBE for six minutes per sequence. We acquired MRI images of the phantom in both static and moving modes, and we also obtained motion-corrected images for the motion mode. We compared the signal stability and signal-to-noise ratio (SNR) of each sequence according to motion state and used the coefficients of variation (CoV) to determine the degree of signal stability. RESULTS With motion, CAIPIRINHA-VIBE showed the best image quality, and the motion correction aligned the images very well. The CoV (%) of CAIPIRINHA-VIBE in the moving mode (18.65) decreased significantly after the motion correction (2.56) (p < 0.001). In contrast, c-VIBE showed severe breathing motion artifacts that did not improve after motion correction. For radial-VIBE, the position of the phantom in the images did not change during motion, but streak artifacts significantly degraded image quality, also after motion correction. In addition, SNR increased in both CAIPIRINHA-VIBE (from 3.37 to 9.41, p < 0.001) and radial-VIBE (from 4.3 to 4.96, p < 0.001) after motion correction. CONCLUSION CAIPIRINHA-VIBE performed best for free-breathing DCE-MRI after motion correction, with excellent image quality.
Collapse
Affiliation(s)
- Chang Kyung Lee
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Korea
| | - Nieun Seo
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Korea.; Department of Radiology, Yonsei University College of Medicine, Severance Hospital, Seoul 03722, Korea
| | - Bohyun Kim
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Korea.; Department of Radiology, Ajou Unversity School of Medicine, Suwon 16499, Korea
| | - Jimi Huh
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Korea.; Department of Radiology, Ulsan University Hospital, Ulsan 44033, Korea
| | - Jeong Kon Kim
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Korea
| | - Seung Soo Lee
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Korea
| | | | - Dominik Nickel
- MR Application Predevelopment, Siemens Healthcare, Erlangen 91052, Germany
| | - Kyung Won Kim
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Korea
| |
Collapse
|
23
|
Hua R, Pozo JM, Taylor ZA, Frangi AF. Multiresolution eXtended Free-Form Deformations (XFFD) for non-rigid registration with discontinuous transforms. Med Image Anal 2017; 36:113-122. [PMID: 27894001 DOI: 10.1016/j.media.2016.10.008] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2016] [Revised: 10/18/2016] [Accepted: 10/26/2016] [Indexed: 10/20/2022]
|
24
|
|
25
|
Suh GY, Choi G, Herfkens RJ, Dalman RL, Cheng CP. Three-Dimensional Modeling Analysis of Visceral Arteries and Kidneys during Respiration. Ann Vasc Surg 2016; 34:250-60. [PMID: 27116907 DOI: 10.1016/j.avsg.2016.04.004] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2015] [Revised: 02/17/2016] [Accepted: 04/14/2016] [Indexed: 11/28/2022]
Abstract
BACKGROUND Visceral arteries are commonly involved in endovascular repair of complex abdominal aortic aneurysms (AAAs). To improve repair techniques and reduce long-term complications involving visceral arteries, it is crucial to understand in vivo arterial geometry and the deformations due to visceral organ movement with respiration. This study quantifies deformation of the celiac, superior mesenteric (SMA), and renal arteries during respiration and correlates the deformations with diaphragmatic excursion. METHODS Sixteen patients with small AAAs underwent magnetic resonance angiography during inspiratory and expiratory breathholds. From geometric models of the aorta and visceral arteries, vessel length, branch angle, curvature, and positions were computed, along with degree of diaphragmatic excursion as indicated by kidney translation. RESULTS From inspiration to expiration, the celiac artery exhibited axial shortening of 4.8 ± 6.4% (P < 0.001) and a mean curvature increase of 0.03 ± 0.02 mm(-1), greater than other visceral arteries (P < 0.01). With expiration, the SMA, left and right renal arteries (LRA and RRA) angled upward by -9.8 ± 6.4°, -6.4 ± 6.4°, and -5.2 ± 5.0°, respectively (P < 0.005). All vessels translated superiorly (P < 0.0005) and posteriorly (P < 0.01), and the SMA translated rightward additionally (P < 0.005). The left and right kidneys translated by 22 ± 9 mm and 21 ± 9 mm, mostly superiorly (P < 0.001). Translations of all visceral arteries were moderately correlated to the right kidney (R > 0.50). Correlation of the LRA with the left kidney was greater than that of the RRA with the right kidney. CONCLUSIONS The celiac artery exhibited less branch angle change, and greater axial and curvature deformations than the other visceral arteries, due to the vicinity to the liver and influence of the median arcuate ligament. Correlation between visceral arteries and kidney translations revealed that diaphragmatic excursion affects vessel mobility. Weaker correlation of the RRA to the right kidney indicates mechanical shielding from the inferior vena cava.
Collapse
Affiliation(s)
- Ga-Young Suh
- Department of Surgery, Stanford University, Stanford, CA.
| | - Gilwoo Choi
- Department of Surgery, Stanford University, Stanford, CA
| | | | | | | |
Collapse
|
26
|
Abstract
Subject motion is unavoidable in clinical and research imaging studies. Breathing is the most important source of motion in whole-body PET and MRI studies, affecting not only thoracic organs but also those in the upper and even lower abdomen. The motion related to the pumping action of the heart is obviously relevant in high-resolution cardiac studies. These two sources of motion are periodic and predictable, at least to a first approximation, which means certain techniques can be used to control the motion (eg, by acquiring the data when the organ of interest is relatively at rest). Additionally, nonperiodic and unpredictable motion can also occur during the scan. One obvious limitation of methods relying on external devices (eg, respiratory bellows or the electrocardiogram signal to monitor the respiratory or cardiac cycle, respectively) to trigger or gate the data acquisition is that the complex motion of internal organs cannot be fully characterized. However, detailed information can be obtained using either the PET or MRI data (or both) allowing the more complete characterization of the motion field so that a motion model can be built. Such a model and the information derived from simple external devices can be used to minimize the effects of motion on the collected data. In the ideal case, all the events recorded during the PET scan would be used to generate a motion-free or corrected PET image. The detailed motion field can be used for this purpose by applying it to the PET data before, during, or after the image reconstruction. Integrating all these methods for motion control, characterization, and correction into a workflow that can be used for routine clinical studies is challenging but could potentially be extremely valuable given the improvement in image quality and reduction of motion-related image artifacts.
Collapse
Affiliation(s)
- Ciprian Catana
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Charlestown, MA.
| |
Collapse
|
27
|
Noorda YH, Bartels LW, Viergever MA, Pluim JPW. Subject-specific four-dimensional liver motion modeling based on registration of dynamic MRI. J Med Imaging (Bellingham) 2016; 3:015002. [PMID: 27493981 DOI: 10.1117/1.jmi.3.1.015002] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2015] [Accepted: 01/25/2016] [Indexed: 11/14/2022] Open
Abstract
Magnetic resonance-guided high intensity focused ultrasound treatment of the liver is a promising noninvasive technique for ablation of liver lesions. For the technique to be used in clinical practice, however, the issue of liver motion needs to be addressed. A subject-specific four-dimensional liver motion model is presented that is created based on registration of dynamically acquired magnetic resonance data. This model can be used for predicting the tumor motion trajectory for treatment planning and to indicate the tumor position for treatment guidance. The performance of the model was evaluated on a dynamic scan series that was not used to build the model. The method achieved an average Dice coefficient of 0.93 between the predicted and actual liver profiles and an average vessel misalignment of 3.0 mm. The model performed robustly, with a small variation in the results per subject. The results demonstrate the potential of the model to be used for MRI-guided treatment of liver lesions. Furthermore, the model can possibly be applied in other image-guided therapies, for instance radiotherapy of the liver.
Collapse
Affiliation(s)
- Yolanda H Noorda
- University Medical Center Utrecht , Image Sciences Institute, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands
| | - Lambertus W Bartels
- University Medical Center Utrecht , Image Sciences Institute, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands
| | - Max A Viergever
- University Medical Center Utrecht , Image Sciences Institute, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands
| | - Josien P W Pluim
- University Medical Center Utrecht , Image Sciences Institute, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands
| |
Collapse
|
28
|
Hamzé N, Peterlík I, Cotin S, Essert C. Preoperative trajectory planning for percutaneous procedures in deformable environments. Comput Med Imaging Graph 2016; 47:16-28. [DOI: 10.1016/j.compmedimag.2015.10.002] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2015] [Revised: 10/01/2015] [Accepted: 10/18/2015] [Indexed: 12/19/2022]
|
29
|
Sagias G, Yiallouras C, Ioannides K, Damianou C. An MRI-conditional motion phantom for the evaluation of high-intensity focused ultrasound protocols. Int J Med Robot 2015; 12:431-41. [PMID: 27593511 DOI: 10.1002/rcs.1709] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/27/2015] [Indexed: 11/11/2022]
Abstract
BACKGROUND The respiratory motion of abdominal organs is a serious obstacle in high-intensity focused ultrasound (HIFU) treatment with magnetic resonance imaging (MRI) guidance. In this study, a two-dimensional (2D) MRI-conditional motion phantom device was developed in order to evaluate HIFU protocols in synchronized and non-synchronized ablation of moving targets. MATERIALS AND METHODS The 2D phantom device simulates the respiratory motion of moving organs in both the left-right and craniocaudal directions. The device consists of MR-conditional materials which have been produced by a three-dimensional (3D) printer. RESULTS The MRI compatibility of the motion phantom was tested successfully in an MRI scanner. In vitro experiments were carried out to evaluate HIFU ablation protocols that are minimally affected by target motion. CONCLUSION It was shown that only in synchronized mode does HIFU produce thermal lesions, as tested on a gel phantom mimicking the moving target. The MRI-conditional phantom device was shown to be functional for its purpose and can be used as an evaluation tool for testing HIFU protocols for moving targets in an MRI environment. Copyright © 2015 John Wiley & Sons, Ltd.
Collapse
|
30
|
Electromagnetic organ tracking allows for real-time compensation of tissue shift in image-guided laparoscopic rectal surgery: results of a phantom study. Surg Endosc 2015; 30:495-503. [DOI: 10.1007/s00464-015-4231-9] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2014] [Accepted: 04/20/2015] [Indexed: 02/01/2023]
|
31
|
Haji K, Royse A, Tharmaraj D, Haji D, Botha J, Royse C. Diaphragmatic regional displacement assessed by ultrasound and correlated to subphrenic organ movement in the critically ill patients—an observational study. J Crit Care 2015; 30:439.e7-13. [DOI: 10.1016/j.jcrc.2014.10.028] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2014] [Revised: 09/19/2014] [Accepted: 10/27/2014] [Indexed: 10/24/2022]
|
32
|
Evaluation of Image Registration in Subtracted 3D Dynamic Contrast-Enhanced MRI of Treated Hepatocellular Carcinoma. AJR Am J Roentgenol 2015; 204:287-96. [DOI: 10.2214/ajr.13.12417] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
33
|
Lin YH, Huang SM, Huang CY, Tu YN, Liu SH, Huang TC. Quantitative analysis of respiration-related movement for abdominal artery in multiphase hepatic CT. PLoS One 2014; 9:e114222. [PMID: 25536144 PMCID: PMC4275208 DOI: 10.1371/journal.pone.0114222] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2014] [Accepted: 11/04/2014] [Indexed: 11/21/2022] Open
Abstract
Objectives Respiration-induced motion in the liver causes potential errors on the measurement of contrast medium in abdominal artery from multiphase hepatic CT scans. In this study, we investigated the use of hepatic CT images to quantitatively estimate the abdominal artery motion due to respiration by optical flow method. Materials and Methods A total of 132 consecutive patients were included in our patient cohort. We apply the optical flow method to compute the motion of the abdominal artery due to respiration. Results The minimum and maximum displacements of the abdominal artery motion were 0.02 and 30.87 mm by manual delineation, 0.03 and 40.75 mm calculated by optical flow method, respectively. Both high consistency and correlation between the present method and the physicians’ manual delineations were acquired with the regression equation of movement, y = 0.81x+0.25, r = 0.95, p<0.001. Conclusion We estimated the motion of abdominal artery due to respiration using the optical flow method in multiphase hepatic CT scans and the motion estimations were validated with the visualization of physicians. The quantitative analysis of respiration-related movement of abdominal artery could be used for motion correction in the measurement of contrast medium passing though abdominal artery in multiphase CT liver scans.
Collapse
Affiliation(s)
- Yang-Hsien Lin
- Department of Biomedical Imaging and Radiological Science, China Medical University, Taichung City, Taiwan
| | - Shih-Min Huang
- Department of Radiology, China Medical University Hospital, Taichung City, Taiwan
| | - Chin-Yi Huang
- Department of Diagnostic Radiology, Peng Hu Hospital, Ministry of Health and Welfare, Peng Hu City, Taiwan
| | - Yun-Niang Tu
- Department of Diagnostic Radiology, Peng Hu Hospital, Ministry of Health and Welfare, Peng Hu City, Taiwan
| | - Shing-Hong Liu
- Department of Computer Science and Information Engineering, Chaoyang University of Technology, Taichung, Taiwan
| | - Tzung-Chi Huang
- Department of Biomedical Imaging and Radiological Science, China Medical University, Taichung City, Taiwan
- Department of Biomedical Informatics, Asia University, Taichung City, Taiwan
- * E-mail:
| |
Collapse
|
34
|
Attarwala AA, Molina-Duran F, Büsing KA, Schönberg SO, Bailey DL, Willowson K, Glatting G. Quantitative and qualitative assessment of Yttrium-90 PET/CT imaging. PLoS One 2014; 9:e110401. [PMID: 25369020 PMCID: PMC4219690 DOI: 10.1371/journal.pone.0110401] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2014] [Accepted: 09/22/2014] [Indexed: 11/24/2022] Open
Abstract
Yttrium-90 is known to have a low positron emission decay of 32 ppm that may allow for personalized dosimetry of liver cancer therapy with 90Y labeled microspheres. The aim of this work was to image and quantify 90Y so that accurate predictions of the absorbed dose can be made. The measurements were performed within the QUEST study (University of Sydney, and Sirtex Medical, Australia). A NEMA IEC body phantom containing 6 fillable spheres (10–37 mm ∅) was used to measure the 90Y distribution with a Biograph mCT PET/CT (Siemens, Erlangen, Germany) with time-of-flight (TOF) acquisition. A sphere to background ratio of 8∶1, with a total 90Y activity of 3 GBq was used. Measurements were performed for one week (0, 3, 5 and 7 d). he acquisition protocol consisted of 30 min-2 bed positions and 120 min-single bed position. mages were reconstructed with 3D ordered subset expectation maximization (OSEM) and point spread function (PSF) for iteration numbers of 1–12 with 21 (TOF) and 24 (non-TOF) subsets and CT based attenuation and scatter correction. Convergence of algorithms and activity recovery was assessed based on regions-of-interest (ROI) analysis of the background (100 voxels), spheres (4 voxels) and the central low density insert (25 voxels). For the largest sphere, the recovery coefficient (RC) values for the 30 min –2-bed position, 30 min-single bed and 120 min-single bed were 1.12±0.20, 1.14±0.13, 0.97±0.07 respectively. For the smaller diameter spheres, the PSF algorithm with TOF and single bed acquisition provided a comparatively better activity recovery. Quantification of Y-90 using Biograph mCT PET/CT is possible with a reasonable accuracy, the limitations being the size of the lesion and the activity concentration present. At this stage, based on our study, it seems advantageous to use different protocols depending on the size of the lesion.
Collapse
Affiliation(s)
- Ali Asgar Attarwala
- Medical Radiation Physics/Radiation Protection, Universitätsmedizin Mannheim, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Flavia Molina-Duran
- Medical Radiation Physics/Radiation Protection, Universitätsmedizin Mannheim, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Karen-Anett Büsing
- Institute of Clinical Radiology and Nuclear Medicine, Universitätsmedizin Mannheim, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Stefan O. Schönberg
- Institute of Clinical Radiology and Nuclear Medicine, Universitätsmedizin Mannheim, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Dale L. Bailey
- Department of Nuclear Medicine, Royal North Shore Hospital, Sydney, Australia
| | - Kathy Willowson
- Institute of Medical Physics, School of Physics, University of Sydney, Sydney, NSW, Australia
| | - Gerhard Glatting
- Medical Radiation Physics/Radiation Protection, Universitätsmedizin Mannheim, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
- * E-mail:
| |
Collapse
|
35
|
Tsauo J, Luo X, Ye L, Li X. Three-Dimensional Path Planning Software-Assisted Transjugular Intrahepatic Portosystemic Shunt: A Technical Modification. Cardiovasc Intervent Radiol 2014; 38:742-6. [DOI: 10.1007/s00270-014-0931-0] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/22/2014] [Accepted: 05/03/2014] [Indexed: 11/29/2022]
|
36
|
Organ-focused mutual information for nonrigid multimodal registration of liver CT and Gd–EOB–DTPA-enhanced MRI. Med Image Anal 2014; 18:22-35. [DOI: 10.1016/j.media.2013.09.002] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2012] [Revised: 08/07/2013] [Accepted: 09/05/2013] [Indexed: 11/23/2022]
|
37
|
Virtual liver resection: computer-assisted operation planning using a three-dimensional liver representation. JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES 2013; 20:157-64. [PMID: 23135735 DOI: 10.1007/s00534-012-0574-y] [Citation(s) in RCA: 64] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
In liver surgery, understanding the complicated liver structures and a detailed evaluation of the functional liver remnant volume are essential to perform safe surgical procedures. Recent advances in imaging technology have enabled operation planning using three-dimensional (3D) image-processing software. Virtual liver resection systems provide (1) 3D imaging of liver structures, (2) detailed volumetric analyses based on portal perfusion, and (3) quantitative estimates of the venous drainage area, enabling the investigation of uncharted fields that cannot be examined using a conventional two-dimensional modality. The next step in computer-assisted liver surgery is the application of a virtual hepatectomy to real-time operations. However, the need for a precise alignment between the preoperative imaging data and the intraoperative situation remains to be adequately addressed, since the liver is subject to deformation and respiratory movements during the surgical procedures. We expect that the practical application of a navigation system for transferring the preoperative planning to real-time operations could make liver surgery safer and more standardized in the near future.
Collapse
|
38
|
Eisma R, Gueorguieva M, Immel E, Toomey R, Mcleod G, Soames R, Melzer A. Liver displacement during ventilation in Thiel embalmed human cadavers – a possible model for research and training in minimally invasive therapies. MINIM INVASIV THER 2013; 22:291-6. [DOI: 10.3109/13645706.2013.769451] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
39
|
Galloway RL, Herrell SD, Miga MI. Image-Guided Abdominal Surgery and Therapy Delivery. JOURNAL OF HEALTHCARE ENGINEERING 2012; 3:203-228. [PMID: 25077012 PMCID: PMC4112601 DOI: 10.1260/2040-2295.3.2.203] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2011] [Accepted: 07/01/2011] [Indexed: 01/31/2023]
Abstract
Image-Guided Surgery has become the standard of care in intracranial neurosurgery providing more exact resections while minimizing damage to healthy tissue. Moving that process to abdominal organs presents additional challenges in the form of image segmentation, image to physical space registration, organ motion and deformation. In this paper, we present methodologies and results for addressing these challenges in two specific organs: the liver and the kidney.
Collapse
Affiliation(s)
- Robert L. Galloway
- Department of Biomedical Engineering
- Department of Neurosurgery
- Department of Surgery
| | | | - Michael I. Miga
- Department of Biomedical Engineering
- Department of Neurosurgery
- Department of Radiology and Radiological Sciences Vanderbilt University
| |
Collapse
|
40
|
Improved imaging of intrahepatic colorectal metastases with 18F-fluorodeoxyglucose respiratory-gated positron emission tomography. Nucl Med Commun 2012; 33:656-62. [DOI: 10.1097/mnm.0b013e328351fce8] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
41
|
A study of porcine liver motion during respiration for improving targeting in image-guided needle placements. Int J Comput Assist Radiol Surg 2012; 8:15-27. [DOI: 10.1007/s11548-012-0745-y] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2012] [Accepted: 05/01/2012] [Indexed: 10/28/2022]
|
42
|
Szegedi M, Sarkar V, Rassiah-Szegedi P, Wang B, Huang YJ, Zhao H, Salter B. 4D CT image acquisition errors in SBRT of liver identified using correlation. J Appl Clin Med Phys 2012; 13:3564. [PMID: 22231209 PMCID: PMC5716128 DOI: 10.1120/jacmp.v13i1.3564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2011] [Revised: 09/30/2011] [Accepted: 10/05/2011] [Indexed: 12/02/2022] Open
Abstract
In the AAPM Report 80,(1) the imaging modality of 4D CT and respiration‐correlated CT was declared a “promising solution for obtaining high‐quality CT data in the presence of respiratory motion”. To gather anatomically correct data over time, the existence of correlation between the internal organ movement and an external surrogate has to be assumed. For the in‐house evaluation of such correlation, we retrospectively analyzed 21 four‐dimensional computer tomography (4D CT) scans of five patients, out of which the artifacts experienced in three patients are shown here. To provide context and a baseline for the analysis of patient motion, a real‐tissue liver phantom was used with a solid water block and liver tissue. The superior–inferior motion of fiducials in phantom and patients was correlated to the recorded anterior–posterior motion of an external surrogate marker on the chest. The use of a solid water block yielded a measurable correlation coefficient of 0.98 or better using a sinusoidal animation pattern. With sinusoidally‐animated liver tissue, the minimum correlation observed was 0.96. Comparing this to retrospective patient data, we found three cases of a change in the correlation coefficient, or simply a low correlation. The source of this low correlation was investigated by careful examination of the breathing traces and the CT‐phase assignments used to reconstruct the datasets. Consequences of nonregular breathing are elaborated on. We demonstrate the impact of wrong phase assignments and missing image information in the 4D CT phase sampling processes. We also show how daily patient‐based correlation analysis can indicate changes in breathing traces, which can be significant enough to decrease, or completely eliminate, previously existing correlation. PACS numbers: 87.57.‐s, 87.57.Q‐, 87.57.cp, 87.57.N‐, 87.55.Qr
Collapse
Affiliation(s)
- Martin Szegedi
- Department of Radiation Oncology, University of Utah, Salt Lake City, UT 84112, USA.
| | | | | | | | | | | | | |
Collapse
|
43
|
Abstract
In minimally invasive surgery or needle insertion procedures, the ultrasound imaging can easily and safely be used to visualize the target to reach. However the manual stabilization of the view of this target, which undergoes the physiological motions of the patient, can be a challenge for the surgeon. In this paper, we propose to perform this stabilization with a robotic arm equipped with a 2D ultrasound probe. The six degrees of freedom of the probe are controlled by an image-based approach, where we choose as visual feedback the image intensity. The accuracy of the control law is ensured by the consideration of the periodicity of the physiological motions in a predictive controller. Tracking tasks performed on a realistic abdominal phantom validate the proposed approach and its robustness to deformation is assessed on a gelatin-made deformable phantom.
Collapse
|
44
|
Mulé S, Kachenoura N, Lucidarme O, De Oliveira A, Pellot-Barakat C, Herment A, Frouin F. An automatic respiratory gating method for the improvement of microcirculation evaluation: application to contrast-enhanced ultrasound studies of focal liver lesions. Phys Med Biol 2011; 56:5153-65. [PMID: 21775793 DOI: 10.1088/0031-9155/56/16/005] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Contrast-enhanced ultrasound (CEUS), with the recent development of both contrast-specific imaging modalities and microbubble-based contrast agents, allows noninvasive quantification of microcirculation in vivo. Nevertheless, functional parameters obtained by modeling contrast uptake kinetics could be impaired by respiratory motion. Accordingly, we developed an automatic respiratory gating method and tested it on 35 CEUS hepatic datasets with focal lesions. Each dataset included fundamental mode and cadence contrast pulse sequencing (CPS) mode sequences acquired simultaneously. The developed method consisted in (1) the estimation of the respiratory kinetics as a linear combination of the first components provided by a principal components analysis constrained by a prior knowledge on the respiratory rate in the frequency domain, (2) the automated generation of two respiratory-gated subsequences from the CPS mode sequence by detecting end-of-inspiration and end-of-expiration phases from the respiratory kinetics. The fundamental mode enabled a more reliable estimation of the respiratory kinetics than the CPS mode. The k-means algorithm was applied on both the original CPS mode sequences and the respiratory-gated subsequences resulting in clustering maps and associated mean kinetics. Our respiratory gating process allowed better superimposition of manually drawn lesion contours on k-means clustering maps as well as substantial improvement of the quality of contrast uptake kinetics. While the quality of maps and kinetics was satisfactory in only 11/35 datasets before gating, it was satisfactory in 34/35 datasets after gating. Moreover, noise amplitude estimated within the delineated lesions was reduced from 62 ± 21 to 40 ± 10 (p < 0.01) after gating. These findings were supported by the low residual horizontal (0.44 ± 0.29 mm) and vertical (0.15 ± 0.16 mm) shifts found during manual motion correction of each respiratory-gated subsequence. The developed technique could be used as a basis for accurate quantification of perfusion parameters for the evaluation and follow-up of patients under antiangiogenic therapies.
Collapse
Affiliation(s)
- S Mulé
- INSERM UMR-S 678, 75634 Paris Cedex 13, France.
| | | | | | | | | | | | | |
Collapse
|
45
|
Auboiroux V, Dumont E, Petrusca L, Viallon M, Salomir R. An MR-compliant phased-array HIFU transducer with augmented steering range, dedicated to abdominal thermotherapy. Phys Med Biol 2011; 56:3563-82. [PMID: 21606558 DOI: 10.1088/0031-9155/56/12/008] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
A novel architecture for a phased-array high intensity focused ultrasound (HIFU) device was investigated, aiming to increase the capabilities of electronic steering without reducing the size of the elementary emitters. The principal medical application expected to benefit from these developments is the time-effective sonication of large tumours in moving organs. The underlying principle consists of dividing the full array of transducers into multiple sub-arrays of different resonance frequencies, with the reorientation of these individual emitters, such that each sub-array can focus within a given spatial zone. To enable magnetic resonance (MR) compatibility of the device and the number of output channels from the RF generator to be halved, a passive spectral multiplexing technique was used, consisting of parallel wiring of frequency-shifted paired piezoceramic emitters with intrinsic narrow-band response. Two families of 64 emitters (circular, 5 mm diameter) were mounted, with optimum efficiency at 0.96 and 1.03 MHz, respectively. Two different prototypes of the HIFU device were built and tested, each incorporating the same two families of emitters, but differing in the shape of the rapid prototyping plastic support that accommodated the transducers (spherical cap with radius of curvature/aperture of 130 mm/150 mm and, respectively, 80 mm/110 mm). Acoustic measurements, MR-acoustic radiation force imaging (ex vivo) and MR-thermometry (ex vivo and in vivo) were used for the characterization of the prototypes. Experimental results demonstrated an augmentation of the steering range by 80% along one preferentially chosen axis, compared to a classic spherical array of the same total number of elements. The electric power density provided to the piezoceramic transducers exceeded 50 W cm(-2) CW, without circulation of coolant water. Another important advantage of the current approach is the versatility of reshaping the array at low cost.
Collapse
|
46
|
Zho SY, Park J, Choi JY, Kim DH. Respiratory motion compensated MR cholangiopancreatography at 3.0 Tesla. J Magn Reson Imaging 2011; 32:726-32. [PMID: 20815074 DOI: 10.1002/jmri.22307] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To reduce irregular respiratory motion-induced artifacts in free-breathing prospective navigator-triggered three-dimensional (3D) MR cholangiopancreatography (MRCP). MATERIALS AND METHODS A reference respiration model was estimated from the first-five respiration periods during the initial navigator scan. With the navigator information acquired before and after triggering, the un-acquired diaphragm position during the actual imaging was interpolated using the amplitude-scaled reference model. Craniocaudal translational motion during imaging was retrospectively corrected using the estimated diaphragm position. T2-weighted 3D MRCP data were acquired from 17 healthy volunteers. For quantitative analysis, contrast-to-noise ratio (CNR) and relative contrast (RC) of the biliary tree and gallbladder were compared using the paired t-test. RESULTS The CNR and RC of the biliary tree and gallbladder were significantly higher (P < 0.05) in the maximum intensity projection images after motion compensation. CONCLUSION The proposed algorithm can be an effective tool to reduce the irregular respiratory motion-induced artifacts in 3D MRCP imaging.
Collapse
Affiliation(s)
- Sang-Young Zho
- Department of Electrical and Electronic Engineering, Yonsei University, Seoul, Korea
| | | | | | | |
Collapse
|
47
|
Hostettler A, Nicolau S, Rémond Y, Marescaux J, Soler L. A real-time predictive simulation of abdominal viscera positions during quiet free breathing. PROGRESS IN BIOPHYSICS AND MOLECULAR BIOLOGY 2010; 103:169-84. [DOI: 10.1016/j.pbiomolbio.2010.09.017] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/16/2010] [Revised: 08/30/2010] [Accepted: 09/15/2010] [Indexed: 01/27/2023]
|
48
|
Hostettler A, George D, Rémond Y, Nicolau SA, Soler L, Marescaux J. Bulk modulus and volume variation measurement of the liver and the kidneys in vivo using abdominal kinetics during free breathing. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2010; 100:149-157. [PMID: 20371130 DOI: 10.1016/j.cmpb.2010.03.003] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/03/2009] [Revised: 10/19/2009] [Accepted: 03/01/2010] [Indexed: 05/29/2023]
Abstract
This article presents a method of predictive simulation, patient-dependant, in real time of the abdominal organ positions during free breathing. The method, that considers both influence of the abdominal breathing and thoracic breathing, needs a tracking of the patient skin and a model of the patient-specific modification of the diaphragm shape. From a measurement of the abdomen viscera kinematic during free breathing, we evaluate through a finite element analysis, the stress field sustained by the organs for a hyperelastic mechanical behaviour using large strain theory. From this analysis, we deduce an in vivo Poisson's ratio and a homogeneous bulk modulus of the liver and kidneys, and compare it to the ones in vitro available in the literature.
Collapse
Affiliation(s)
- Alexandre Hostettler
- Institut de Mécanique des Fluides et des Solides, Université de Strasbourg, CNRS, 2 rue boussingault, F-67000 Strasbourg, Alsace, France
| | | | | | | | | | | |
Collapse
|
49
|
Müller SA, Maier-Hein L, Tekbas A, Seitel A, Ramsauer S, Radeleff B, Franz AM, Tetzlaff R, Mehrabi A, Wolf I, Kauczor HU, Meinzer HP, Schmied BM. Navigated liver biopsy using a novel soft tissue navigation system versus CT-guided liver biopsy in a porcine model: a prospective randomized trial. Acad Radiol 2010; 17:1282-7. [PMID: 20832025 DOI: 10.1016/j.acra.2010.05.017] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2010] [Revised: 05/17/2010] [Accepted: 05/19/2010] [Indexed: 12/17/2022]
Abstract
RATIONALE AND OBJECTIVES The aim of this prospective, randomized animal study was to compare a new computer guided needle-based navigation system for liver biopsy with conventional computed tomography (CT)-guided liver biopsy. Computer-navigated interventions provide continuous needle tracking during motion and deformation from patient respiration and movement. MATERIALS AND METHODS Twenty artificial tumors of about 5 mm in diameter were injected into the livers of five pigs, each at a different site. Each tumor was targeted by conventional CT-guided and computer navigated intervention. Intervention was considered complete after successful tumor biopsy. Data on procedure time, number of CT scans performed, accuracy, and success rate were recorded. RESULTS All tumors (100%) were biopsied successfully. Mean procedural time was comparable between the two techniques (20 ± 9 minutes conventional versus 20 ± 8 minutes navigation). Mean number of CT scans were 1.2 ± 0.4 with navigation and 6.1 ± 3.8 with the conventional technique (P < .01). The dose-length product in the conventional group was significantly higher (212 ± 116 mGy × cm) than in the navigated group (78 ± 22 mGy × cm; P < .001). Mean number of capsule penetrations was 4 ± 1 with navigation versus 2 ± 1 with the conventional technique (P < .001). CONCLUSION Computer-navigated liver biopsy may provide a promising and innovative device for easy, rapid, and successful liver biopsies with low morbidity. Further technical improvements and clinical studies in humans are required.
Collapse
|
50
|
Widmann G, Schullian P, Haidu M, Wiedermann FJ, Bale R. Respiratory motion control for stereotactic and robotic liver interventions. Int J Med Robot 2010; 6:343-9. [DOI: 10.1002/rcs.343] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|