451
|
Tumor-suppressor Gene Promoter Hypermethylation in Saliva of Head and Neck Cancer Patients. Transl Oncol 2012; 5:321-6. [PMID: 23066440 DOI: 10.1593/tlo.12232] [Citation(s) in RCA: 70] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2012] [Revised: 08/06/2012] [Accepted: 08/06/2012] [Indexed: 12/19/2022] Open
Abstract
Head and neck squamous cell carcinoma (HNSCC) accounts for a bulk of the oral and laryngeal cancers, the majority (70%) of which are associated with smoking and excessive drinking, major known risk factors for the development of HNSCC. In contrast to reports that suggest an inverse relationship between smoking and global DNA CpG methylation, hypermethylation of promoters of a number of genes was detected in saliva collected from patients with HNSCC. Using a sensitive methylation-specific polymerase chain reaction (MSP) assay to determine specific methylation events in the promoters of RASSF1A, DAPK1, and p16 genes, we demonstrate that we can detect tumor presence with an overall accuracy of 81% in the DNA isolated from saliva of patients with HNSCC (n = 143) when compared with the DNA isolated from the saliva of healthy nonsmoker controls (n = 31). The specificity for this MSP panel was 87% and the sensitivity was 80% (with a Fisher exact test P < .0001). In addition, the test panel performed extremely well in the detection of the early stages of HNSCCs, with a sensitivity of 94% and a specificity of 87%, and a high κ concordance value of 0.8, indicating an excellent overall agreement between the presence of HNSCC and a positive MSP panel result. In conclusion, we demonstrate that the promoter methylation of RASSF1A, DAPK1, and p16 MSP panel is useful in detecting hypermethylation events in a noninvasive manner in patients with HNSCC.
Collapse
|
452
|
Mohamed R, Campbell JL, Cooper-White J, Dimeski G, Punyadeera C. The impact of saliva collection and processing methods on CRP, IgE, and Myoglobin immunoassays. Clin Transl Med 2012; 1:19. [PMID: 23369566 PMCID: PMC3560976 DOI: 10.1186/2001-1326-1-19] [Citation(s) in RCA: 102] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2012] [Accepted: 07/25/2012] [Indexed: 12/16/2022] Open
Abstract
UNLABELLED BACKGROUND Owing to its ease of collection, saliva is potentially the sample of choice in diagnosis. Salivary biomolecules have provided a porthole in surveying a person's health and well-being. Our study aims were (1) to demonstrate the effects of pre-analytical steps, collection and pre-processing techniques on salivary protein detection and (2) to establish an indication of salivary reference intervals for 3 biomolecules of clinical interest. METHODS Saliva samples were collected from participants (n = 25, ages 20-35 years) using the following methods: no stimulation (resting/unstimulated), mechanical, and acid stimulation. The saliva was prepared for analysis by: unprocessed, post standard centrifugation in a container without any additives, and centrifugation using Centrifugal Filter Unit (Amicon® Ultra-0.5). AlphaLisa® assays were used to measure the levels of C-Reactive Protein (CRP), Immunoglobin (IgE) and myoglobin in saliva samples. RESULTS Saliva flow rates were lowest with the resting/drooling collection method. The lowest total protein concentration was with acid stimulation. Unstimulated and mechanically stimulated collections produced no effect on the CRP and IgE levels while myoglobin levels were highest with the unstimulated collection. Acid stimulation had a negative impact on the measured concentrations of IgE and myoglobin (except for CRP levels). CONCLUSION Mechanical stimulation was the most viable option for collecting saliva without affecting the levels of CRP and myoglobin. The processing methods had an adverse effect on the concentration of total protein as well as on CRP and IgE concentrations.
Collapse
Affiliation(s)
- Roslinda Mohamed
- The Australian Institute for Bioengineering and Nanotechnology, St-Lucia, Australia
| | | | - Justin Cooper-White
- The Australian Institute for Bioengineering and Nanotechnology, St-Lucia, Australia
- The School of Chemical Engineering and the University of Queensland, Queensland, Australia
| | - Goce Dimeski
- Chemical Pathology, Princess Alexandra Hospital, Pathology Queensland, Woolloongabba, Australia
- School of Medicine, Southside Clinical School, The University of Queensland, Herston, Australia
| | - Chamindie Punyadeera
- The Australian Institute for Bioengineering and Nanotechnology, St-Lucia, Australia
- The School of Chemical Engineering and the University of Queensland, Queensland, Australia
- Saliva Translational Research Group, Tissue Engineering and Microfluidic Laboratory, the Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, Old Cooper Road, St. Lucia, Queensland, 4072, Australia
| |
Collapse
|
453
|
Abstract
Alternative specimens (e.g., hair and saliva) are well established in forensic toxicology and provide significant benefits as noninvasive, inexpensive alternatives to blood with access to improved long-term retrospection. Based on these experiences, the question of potential applications and limitations of alternative specimens in doping control arose. Compounds prohibited at all times (e.g., clenbuterol, β2 agonists, estrogen-receptor modulators) may be successfully tested and clearly interpreted in alternative specimens. In contrast, prohibition of certain compounds in sport are limited to time ranges (e.g., stimulants are only prohibited in-competition), dosages or administration routes (e.g., systemic uptake of glucocorticosteroids). This cannot be properly differentiated by semiquantitative tests (e.g., hair analyses), but may be distinguished in saliva. Similarly, proof of external administration of endogenous steroids (e.g., testosterone) only seems to be achievable by quantitative analysis of saliva. Moreover, the retrospective monitoring of the relevance of social drugs or upcoming (unapproved) substances represents promising applications of hair tests in doping control.
Collapse
|
454
|
Development of transcriptomic biomarker signature in human saliva to detect lung cancer. Cell Mol Life Sci 2012; 69:3341-3350. [PMID: 22689099 DOI: 10.1007/s00018-012-1027-0] [Citation(s) in RCA: 109] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2012] [Revised: 04/23/2012] [Accepted: 05/07/2012] [Indexed: 01/02/2023]
Abstract
Lung cancer is the leading cause of cancer death for both men and women worldwide. Since most of the symptoms found for lung cancer are nonspecific, diagnosis is mostly done at late and progressed stage with the consecutive poor therapy outcome. Effective early detection techniques are sorely needed. The emerging field of salivary diagnostics could provide scientifically credible, easy-to-use, non-invasive and cost-effective detection methods. Recent advances have allowed us to develop discriminatory salivary biomarkers for a variety of diseases from oral to systematic diseases. In this study, salivary transcriptomes of lung cancer patients were profiled and led to the discovery and pre-validation of seven highly discriminatory transcriptomic salivary biomarkers (BRAF, CCNI, EGRF, FGF19, FRS2, GREB1, and LZTS1). The logistic regression model combining five of the mRNA biomarkers (CCNI, EGFR, FGF19, FRS2, and GREB1) could differentiate lung cancer patients from normal control subjects, yielding AUC value of 0.925 with 93.75 % sensitivity and 82.81 % specificity in the pre-validation sample set. These salivary mRNA biomarkers possess the discriminatory power for the detection of lung cancer. This report provides the proof of concept of salivary biomarkers for the non-invasive detection of the systematic disease. These results poised the salivary biomarkers for the initiation of a multi-center validation in a definitive clinical context.
Collapse
|
455
|
Schulz BL, Cooper-White J, Punyadeera CK. Saliva proteome research: current status and future outlook. Crit Rev Biotechnol 2012; 33:246-59. [DOI: 10.3109/07388551.2012.687361] [Citation(s) in RCA: 101] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
456
|
Out D, Hall RJ, Granger DA, Page GG, Woods SJ. Assessing salivary C-reactive protein: longitudinal associations with systemic inflammation and cardiovascular disease risk in women exposed to intimate partner violence. Brain Behav Immun 2012; 26:543-51. [PMID: 22326517 PMCID: PMC3334360 DOI: 10.1016/j.bbi.2012.01.019] [Citation(s) in RCA: 95] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/07/2011] [Revised: 01/14/2012] [Accepted: 01/26/2012] [Indexed: 10/14/2022] Open
Abstract
This study evaluated individual differences in levels of C-reactive protein (CRP) measured in saliva, cross-sectionally and prospectively, in relation to systemic inflammation and risk for cardiovascular disease (CVD). Plasma and saliva samples, later assayed for CRP, were collected multiple times from an ethnically diverse group of women seeking help from domestic violence crisis shelters-agencies (N=107; mean age at study start=34 years). Plasma and saliva CRP levels were moderately associated cross-sectionally and across two years. There were indications that saliva CRP levels were, on average, higher in the morning than evening. Higher levels of saliva and plasma CRP were associated with a higher body mass index, but did not differ between women who did and did not smoke. Salivary CRP reliably discriminated between high and low levels of plasma CRP, using a clinically relevant cutoff point of 3mg/L, recommended by the American Heart Association. Results build upon an emerging literature suggesting that under specific conditions levels of CRP in saliva may reflect low-grade inflammation and have the potential to serve as a screen for CVD risk status.
Collapse
Affiliation(s)
- Dorothée Out
- Center for Interdisciplinary Salivary Bioscience Research, School of Nursing, The Johns Hopkins University, Baltimore, Maryland,Centre for Child and Family Studies, Leiden University, Leiden, the Netherlands
| | - Rosalie J. Hall
- Department of Psychology, The University of Akron, Akron, Ohio
| | - Douglas A. Granger
- Center for Interdisciplinary Salivary Bioscience Research, School of Nursing, Bloomberg School of Public Health, and School of Medicine, The Johns Hopkins University, Baltimore, Maryland
| | - Gayle G. Page
- School of Nursing, The Johns Hopkins University, Baltimore, Maryland
| | | |
Collapse
|
457
|
Punyadeera C. Human saliva as a tool to investigate intimate partner violence. Brain Behav Immun 2012; 26:541-2. [PMID: 22388099 DOI: 10.1016/j.bbi.2012.02.006] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/20/2012] [Accepted: 02/20/2012] [Indexed: 10/28/2022] Open
Affiliation(s)
- Chamindie Punyadeera
- Saliva Research Group, Tissue Engineering and Microfluidics Laboratory, Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, Old Cooper Road, St. Lucia, 4072 Queensland, Australia.
| |
Collapse
|
458
|
Peng Y, Chen X, Sato T, Rankin SA, Tsuji RF, Ge Y. Purification and high-resolution top-down mass spectrometric characterization of human salivary α-amylase. Anal Chem 2012; 84:3339-46. [PMID: 22390166 DOI: 10.1021/ac300083y] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Human salivary α-amylase (HSAMY) is a major component of salivary secretions, possessing multiple important biological functions. Here we have established three methods to purify HSAMY in human saliva for comprehensive characterization of HSAMY by high-resolution top-down mass spectrometry (MS). Among the three purification methods, the affinity method based on the enzyme-substrate specific interaction between amylase and glycogen is preferred, providing the highest purity HSAMY with high reproducibility. Subsequently, we employed Fourier transform ion cyclotron resonance MS to analyze the purified HSAMY. The predominant form of α-amylase purified from saliva of various races and genders is nonglycosylated with the same molecular weight of 55,881.2, which is 1885.8 lower than the calculated value based on the DNA-predicted sequence. High-resolution MS revealed the truncation of the first 15 N-terminal amino acids (-1858.96) and the subsequent formation of pyroglutamic acid at the new N-terminus Gln (-17.03). More importantly, five disulfide bonds in HSAMY were identified (-10.08) and effectively localized by tandem MS in conjunction with complete and partial reduction by tris (2-carboxyethyl) phosphine. Overall, this study demonstrates that top-down MS combined with affinity purification and partial reduction is a powerful method for rapid purification and complete characterization of large proteins with complex and overlapping disulfide bond patterns.
Collapse
Affiliation(s)
- Ying Peng
- Human Proteomics Program, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin 53706, USA
| | | | | | | | | | | |
Collapse
|
459
|
Topkas E, Keith P, Dimeski G, Cooper-White J, Punyadeera C. Evaluation of saliva collection devices for the analysis of proteins. Clin Chim Acta 2012; 413:1066-70. [PMID: 22405932 DOI: 10.1016/j.cca.2012.02.020] [Citation(s) in RCA: 105] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2011] [Revised: 01/30/2012] [Accepted: 02/20/2012] [Indexed: 12/20/2022]
Abstract
BACKGROUND Human saliva mirrors the body's health and can be collected non-invasively, does not require specialized skills and is suitable for large population based screening programs. The aims were twofold: to evaluate the suitability of commercially available saliva collection devices for quantifying proteins present in saliva and to provide levels for C-reactive protein (CRP), myoglobin, and immunoglobin E (IgE) in saliva of healthy individuals as a baseline for future studies. METHODS Saliva was collected from healthy volunteers (n=17, ages 18-33years). The following collection methods were evaluated: drool; Salimetrics® Oral Swab (SOS); Salivette® Cotton and Synthetic (Sarstedt) and Greiner Bio-One Saliva Collection System (GBO SCS®). We used AlphaLISA® assays to measure CRP, IgE and myoglobin levels in human saliva. RESULTS Significant (p<0.05) differences in the salivary flow rates were observed based on the method of collection, i.e. salivary flow rates were significantly lower (p<0.05) in unstimulated saliva (i.e. drool and SOS), when compared with mechanically stimulated methods (p<0.05) (Salivette® Cotton and Synthetic) and acid stimulated method (p<0.05) (SCS®). Saliva collected using SOS yielded significantly (p<0.05) lower concentrations of myoglobin and CRP, whilst, saliva collected using the Salivette® Cotton and Synthetic swab yielded significantly (p<0.05) lower myoglobin and IgE concentrations respectively. CONCLUSIONS The results demonstrated significantly relevant differences in analyte levels based on the collection method. Significant differences in the salivary flow rates were also observed depending on the saliva collection method. The data provide preliminary baseline values for salivary CRP, myoglobin, and IgE levels in healthy participants and based on the collection method.
Collapse
Affiliation(s)
- Eleni Topkas
- The Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, Queensland, Australia
| | | | | | | | | |
Collapse
|
460
|
Abstract
The circadian clock orchestrates many aspects of human physiology, and disruption of this clock has been implicated in various pathologies, ranging from cancer to metabolic syndrome and diabetes. Although there is evidence that metabolism and the circadian clockwork are intimately linked on a transcriptional level, whether these effects are directly under clock control or are mediated by the rest-activity cycle and the timing of food intake is unclear. To answer this question, we conducted an unbiased screen in human subjects of the metabolome of blood plasma and saliva at different times of day. To minimize indirect effects, subjects were kept in a 40-h constant routine of enforced posture, constant dim light, hourly isocaloric meals, and sleep deprivation. Under these conditions, we found that ~15% of all identified metabolites in plasma and saliva were under circadian control, most notably fatty acids in plasma and amino acids in saliva. Our data suggest that there is a strong direct effect of the endogenous circadian clock on multiple human metabolic pathways that is independent of sleep or feeding. In addition, they identify multiple potential small-molecule biomarkers of human circadian phase and sleep pressure.
Collapse
|
461
|
Nunes LAS, Brenzikofer R, Macedo DV. Reference intervals for saliva analytes collected by a standardized method in a physically active population. Clin Biochem 2011; 44:1440-4. [DOI: 10.1016/j.clinbiochem.2011.09.012] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2011] [Revised: 09/06/2011] [Accepted: 09/22/2011] [Indexed: 11/16/2022]
|
462
|
Chen HJC, Lin WP. Quantitative analysis of multiple exocyclic DNA adducts in human salivary DNA by stable isotope dilution nanoflow liquid chromatography-nanospray ionization tandem mass spectrometry. Anal Chem 2011; 83:8543-51. [PMID: 21958347 DOI: 10.1021/ac201874d] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
Exocyclic DNA adducts, including 1,N(2)-propano-2'-deoxyguanosine derived from acrolein (AdG) and crotonaldehyde (CdG) and the three lipid peroxidation-related etheno adducts 1,N(6)-etheno-2'-deoxyadenosine (εdAdo), 3,N(4)-etheno-2'-deoxycytidine (εdCyt), and 1,N(2)-etheno-2'-deoxyguanosine (1,N(2)-εdGuo), play an important role in cancer formation and they are associated with oxidative-stress-induced DNA damage. Saliva is an easily accessible and available biological fluid and a potential target of noninvasive biomarkers. In this study, a highly sensitive and specific assay based on isotope dilution nanoflow LC-nanospray ionization tandem mass spectrometry (nanoLC-NSI/MS/MS) is developed for simultaneous detection and quantification of these five adducts in human salivary DNA. The levels of AdG, CdG, εdAdo, εdCyd, and 1,N(2)-εdGuo, measured in 27 human salivary DNA samples from healthy volunteers, were determined as 104 ± 50, 7.6 ± 12, 99 ± 50, 72 ± 49, 391 ± 198 (mean ± SD) in 10(8) normal nucleotides, respectively, starting with 25 μg of DNA isolated from an average of 3 mL of saliva. Statistically significant correlations were found between levels of εdAdo and εdCyd (γ = 0.8007, p < 0.0001), between levels of εdAdo and 1,N(2)-εdGuo (γ = 0.6778, p = 0.0001), between levels of εdCyd and 1,N(2)-εdGuo (γ = 0.5643, p = 0.0022), between levels of AdG and 1,N(2)-εdGuo (γ = 0.5756, p = 0.0017), and between levels of AdG and εdAdo (γ = 0.3969, p = 0.0404). Only 5 μg of DNA sample was analyzed for simultaneous quantification of these adducts. The easy accessibility and availability of saliva and the requirement for the small amount of DNA samples make this nanoLC-NSI/MS/MS assay clinically feasible in assessing the possibility of measuring 1,N(2)-propano-2'-deoxyguanosine and etheno adducts levels in human salivary DNA as noninvasive biomarkers for DNA damage resulting from oxidative stress and for evaluating their roles in cancer formation and prevention.
Collapse
Affiliation(s)
- Hauh-Jyun Candy Chen
- Department of Chemistry and Biochemistry, National Chung Cheng University, Ming-Hsiung, Chia-Yi, Taiwan.
| | | |
Collapse
|