51
|
Thevis M, Schänzer W. Mass spectrometry in sports drug testing: Structure characterization and analytical assays. MASS SPECTROMETRY REVIEWS 2007; 26:79-107. [PMID: 16888758 DOI: 10.1002/mas.20107] [Citation(s) in RCA: 144] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Owing to the sensitive, selective, and unambiguous nature of mass spectrometric analyses, chromatographic techniques interfaced to various kinds of mass spectrometers have become the most frequently employed strategy in the fight against doping. To obtain utmost confidence in analytical assays, mass spectrometric characterization of target analytes and typical dissociation pathways have been utilized as basis for the development of reliable and robust screening as well as confirmation procedures. Methods for qualitative and/or quantitative determinations of prohibited low and high molecular weight drugs have been established in doping control laboratories preferably employing gas or liquid chromatography combined with electron, chemical, or atmospheric pressure ionization followed by analyses using quadrupole, ion trap, linear ion trap, or hyphenated techniques. The versatility of modern mass spectrometers enable specific as well as comprehensive measurements allowing sports drug testing laboratories to determine the misuse of therapeutics such as anabolic-androgenic steroids, stimulants, masking agents or so-called designer drugs in athletes' blood or urine specimens, and a selection of recent developments is summarized in this review.
Collapse
Affiliation(s)
- Mario Thevis
- Institute of Biochemistry and Center for Preventive Doping Research, German Sport University Cologne, Carl-Diem Weg 6, 50933 Cologne, Germany.
| | | |
Collapse
|
52
|
Kaushik R, Levine B, LaCourse WR. A brief review: HPLC methods to directly detect drug glucuronides in biological matrices (Part I). Anal Chim Acta 2006. [DOI: 10.1016/j.aca.2005.09.012] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
53
|
Kushnir MM, Rockwood AL, Nelson GJ, Yue B, Urry FM. Assessing analytical specificity in quantitative analysis using tandem mass spectrometry. Clin Biochem 2005; 38:319-27. [PMID: 15766733 DOI: 10.1016/j.clinbiochem.2004.12.003] [Citation(s) in RCA: 100] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2004] [Revised: 12/07/2004] [Accepted: 12/13/2004] [Indexed: 10/25/2022]
Abstract
OBJECTIVES The necessity of confirmation of compound identity in quantitative analysis is well recognized for methods utilizing single mass spectrometry detection but is not commonly addressed for applications utilizing multiple-stage mass spectrometry (MSn). For MSn detection, no commonly accepted rules for assessment of analytical specificity in quantitative analyses have been established to date. METHODS To assure compound identity, we evaluated approaches based on monitoring multiple mass transitions of a target compound followed by comparison of the branching ratios of the mass transitions. RESULTS Monitoring multiple mass transitions along with evaluation of the ratio of their relative intensities allows the analyst to distinguish the target analyte from interferences in quantitative analysis. The strategy and the acceptance criteria are compound and method specific and should be established during the method development and validation. CONCLUSIONS The certainty of analyte identity is very important in quantitative analysis using MSn detection; methods to verify analyte identity should be used in all critical applications.
Collapse
Affiliation(s)
- Mark M Kushnir
- ARUP Institute for Clinical and Experimental Pathology, Salt Lake City, UT 84108, USA.
| | | | | | | | | |
Collapse
|
54
|
Levsen K, Schiebel HM, Behnke B, Dötzer R, Dreher W, Elend M, Thiele H. Structure elucidation of phase II metabolites by tandem mass spectrometry: an overview. J Chromatogr A 2005; 1067:55-72. [PMID: 15844510 DOI: 10.1016/j.chroma.2004.08.165] [Citation(s) in RCA: 180] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
The present paper provides a summary of the collision-induced dissociation of protonated and deprotonated phase II metabolites of drugs and pesticides. This overview is based on published literature and unpublished data from the authors. In particular, glutathione conjugates and their biotransformation products are discussed in detail. In addition, the fragmentation of the major classes of conjugates, i.e. glucuronides, glucosides, malonylglucosides, sulfates, acetates, methyl and glycine conjugates, is reported. Collision-induced dissociation, as studied by tandem mass spectrometry, allows the rapid identification of the type of conjugate, whereas the exact conjugation site can in general be determined only by additional NMR experiments.
Collapse
Affiliation(s)
- Karsten Levsen
- Fraunhofer Institute of Toxicology and Experimental Medicine, Nikolai-Fuchs-Str 1, D 30625 Hannover, Germany.
| | | | | | | | | | | | | |
Collapse
|
55
|
Sheen JF, Her GR. Application of pentafluorophenyl hydrazine derivatives to the analysis of nabumetone and testosterone in human plasma by liquid chromatography?atmospheric pressure chemical ionization?tandem mass spectrometry. Anal Bioanal Chem 2004; 380:891-7. [PMID: 15700167 DOI: 10.1007/s00216-004-2877-6] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2004] [Revised: 08/06/2004] [Accepted: 09/27/2004] [Indexed: 11/27/2022]
Abstract
Two carbonyl compounds, nabumetone and testosterone, were derivatized with pentafluorophenyl hydrazine (PFPH) and analyzed by atmospheric-pressure chemical-ionization mass spectrometry. The PFPH derivatives underwent dissociative electron capture in negative-ion APCI (ECAPCI) and gave intense [M-20](-) ions in the mass spectra. In positive-ion APCI, the PFPH derivatives underwent efficient protonation and gave intense [M + H](+) ions in the mass spectra. In CID, the major product ions of the [M-20](-) ions in ECAPCI corresponded to the partial moiety of PFPH. In contrast, the major product ions of [M + H](+) corresponded to the partial moiety of the analyte. By using selected reaction monitoring (SRM) detection, low pg of nabumetone (1 pg) and testosterone (7 pg) could be detected in both ECAPCI and positive-ion APCI. In comparison with the detection limits (SRM) of the underivatized analytes, use of the PFPH derivatives resulted in 2500-fold and 35-fold sensitivity enhancements for nabumetone and testosterone, respectively. The PFPH derivatives were applied to the analysis of nabumetone and testosterone in human plasma by both ECAPCI and positive-ion APCI and were found to enable detection of 0.1 ng mL(-1) nabumetone in spiked plasma. For testosterone, endogenous testosterone in female plasma was detected in both ECAPCI and positive-ion APCI.
Collapse
Affiliation(s)
- J F Sheen
- Department of Chemistry, National Taiwan University, Taipei, Taiwan.
| | | |
Collapse
|
56
|
Buiarelli F, Coccioli F, Merolle M, Neri B, Terracciano A. Development of a liquid chromatography–tandem mass spectrometry method for the identification of natural androgen steroids and their conjugates in urine samples. Anal Chim Acta 2004. [DOI: 10.1016/j.aca.2004.09.068] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
57
|
Liquid chromatography clean-up method to improve identification of anabolic agents in human urine by gas chromatography–mass spectrometry. Anal Chim Acta 2004. [DOI: 10.1016/j.aca.2004.03.021] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
58
|
Zhang N, Yang A, Rogers JD, Zhao JJ. Quantitative analysis of simvastatin and its β-hydroxy acid in human plasma using automated liquid–liquid extraction based on 96-well plate format and liquid chromatography-tandem mass spectrometry. J Pharm Biomed Anal 2004; 34:175-87. [PMID: 14738932 DOI: 10.1016/j.japna.2003.08.016] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
An assay based on automated liquid-liquid extraction (LLE) and liquid chromatography-tandem mass spectrometry (LC/MS/MS) has been developed and validated for the quantitative analysis of simvastatin (SV) and its beta-hydroxy acid (SVA) in human plasma. A Packard MultiProbe II workstation was used to convert human plasma samples collected following administration of simvastatin and quality control (QC) samples from individual tubes into 96-well plate format. The workstation was also used to prepare calibration standards and spike internal standards. A Tomtec Quadra 96-channel liquid handling workstation was used to perform LLE based on 96-well plates including adding solvents, separating organic from aqueous layer and reconstitution. SV and SVA were separated through a Kromasil C18 column (50 mm x 2 mm i.d., 5 microm) and detected by tandem mass spectrometry with a TurboIonspray interface. Stable isotope-labeled SV and SVA, 13CD(3)-SV and 13 CD(3)-SVA, were used as the internal standards for SV and SVA, respectively. The automated procedures reduced the overall analytical time (96 samples) to 1/3 of that of manual LLE. Most importantly, an analyst spent only a fraction of time on the 96-well LLE. A limit of quantitation of 50 pg/ml was achieved for both SV and SVA. The interconversion between SV and SVA during the 96-well LLE was found to be negligible. The assay showed very good reproducibility, with intra- and inter-assay precision (%R.S.D.) of less than 7.5%, and accuracy of 98.7-102.3% of nominal values for both analytes. By using this method, sample throughput should be enhanced at least three-fold compared to that of the manual procedure.
Collapse
Affiliation(s)
- Nanyan Zhang
- Department of Drug Metabolism, Merck Research Laboratories, Merck & Co, Inc, WP14-1101, West Point, PA 19486, USA.
| | | | | | | |
Collapse
|
59
|
Abstract
Tandem mass spectrometry is becoming an increasingly important analytical technology in the clinical laboratory environment. Applications in toxicology and therapeutic drug monitoring have opened the door for tandem mass spectrometry and now we are seeing a vast array of new applications being developed. It has been the combination of tandem mass spectrometry with sample introduction techniques employing atmospheric pressure ionization that has enabled this technology to be readily implemented in the clinical laboratory. Although its major research applications started with pharmacology and proteomics, tandem mass spectrometry is being used for a great variety of analyses from steroids to catecholamines to peptides. As with chromatographic methods, tandem mass spectrometry is most cost effective when groups of compounds need to be measured simultaneously. However as the price/performance of this technology continues to improve, it will become even more widely utilized for clinical laboratory applications.
Collapse
Affiliation(s)
- Kent C Dooley
- Department of Pathology and Laboratory Medicine, IWK Health Centre and Department of Pathology, Dalhousie University Medical School, Halifax, Nova Scotia, Canada.
| |
Collapse
|
60
|
Kuuranne T, Kurkela M, Thevis M, Schänzer W, Finel M, Kostiainen R. Glucuronidation of anabolic androgenic steroids by recombinant human UDP-glucuronosyltransferases. Drug Metab Dispos 2003; 31:1117-24. [PMID: 12920167 DOI: 10.1124/dmd.31.9.1117] [Citation(s) in RCA: 77] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
A multidimensional study on the glucuronidation of anabolic androgenic steroids and their phase I metabolites by 11 recombinant human UDP-glucuronosyltransferases (UGTs) was carried out using liquid chromatographic-tandem mass spectrometric analyses. Large differences between the enzymes with respect to the conjugation profiles of the 11 tested aglycones were detected. Two UGTs, 1A6 and 1A7, did not exhibit measurable activity toward any of the aglycones that were examined in this study. Regioselectivity was demonstrated by UGTs 1A8, 1A9, and 2B15 that preferentially catalyzed hydroxyl glucuronidation at the 17beta-position. Most of the other enzymes glucuronidated hydroxyl groups at both the 3alpha- and the 17beta-positions. Clear stereoselectivity was observed in glucuronidation of diastereomeric nandrolone metabolites (5alpha-estran-3alpha-ol-17-one and 5beta-estran-3alpha-ol-17-one), whereas such specificity was not seen when analogous methyltestosterone metabolites were assayed. UGTs 1A1, 1A3, 1A4, 1A8, 1A9, 1A10, 2B4, 2B7, and 2B15 readily glucuronidated 5alpha-androstane-3alpha,17beta-diol, but none of them exhibited methyltestosterone glucuronidation activity. In agreement with the latter observations, we found that the methyltestosterone glucuronidation activity of human liver microsomes is extremely low, whereas in induced rat liver microsomes it was significantly higher. The homology among UGTs 1A7 to 1A10 at the level of amino acid sequence is very high, and it was thus surprising to find large differences in their activity toward this set of aglycones. Furthermore, the high activity of UGT1A8 and 1A10 toward some of the substrates indicates that extrahepatic enzymes might play a role in the metabolism of anabolic androgenic steroids.
Collapse
Affiliation(s)
- Tiia Kuuranne
- Division of Pharmaceutical Chemistry, University of Helsinki, Finland
| | | | | | | | | | | |
Collapse
|
61
|
Griffiths WJ. Tandem mass spectrometry in the study of fatty acids, bile acids, and steroids. MASS SPECTROMETRY REVIEWS 2003; 22:81-152. [PMID: 12820273 DOI: 10.1002/mas.10046] [Citation(s) in RCA: 155] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
Over the last 50 years, the mass spectrometry of lipids has evolved to become one of the most mature techniques in biomolecule analysis. Many volatile and non-polar lipids are directly amenable to analysis by gas-chromatography-mass spectrometry (GC-MS), a technique that combines the unsurpassed separation properties of gas-chromatography with the sensitivity and selectivity of electron ionization mass spectrometry. Less volatile and/or thermally labile lipids can be analyzed by GC-MS, following appropriate sample derivatization. However, many complex lipids are not readily analyzed by GC-MS, and it is these molecules that are the subject of the current review. Since the early 1970s, there have been three outstanding developments in mass spectrometry that are particularly appropriate in lipid analysis; i.e., the introduction of (i) fast atom bombardment (FAB); (ii) electrospray (ES); and (iii) tandem mass spectrometry (MS/MS). The FAB and ES ionization techniques will be discussed in relation to MS/MS, and examples of their application in biochemical studies will be presented. The review will concentrate on the analysis of fatty acids, bile acids, steroid conjugates, and neutral steroids.
Collapse
Affiliation(s)
- William J Griffiths
- Department of Pharmaceutical and Biological Chemistry, The School of Pharmacy, University of London, 29-39 Brunswick Square, London WC1N 1AX, United Kingdom.
| |
Collapse
|
62
|
Greig MJ, Bolaños B, Quenzer T, Bylund JMR. Fourier transform ion cyclotron resonance mass spectrometry using atmospheric pressure photoionization for high-resolution analyses of corticosteroids. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2003; 17:2763-2768. [PMID: 14673824 DOI: 10.1002/rcm.1257] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS) was coupled with atmospheric pressure photoionization (APPI) for the first time and used for the analysis of several corticosteroids.1 The analytes showed excellent response using APPI when compared with both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI). APPI has the advantage of requiring less heat for desolvation, resulting in less thermal degradation of the analytes and higher signal-to-noise than APCI. In terms of ultimate sensitivity, APPI is more efficient than either ESI or APCI for the analysis of corticosteroids. With some compounds, the high-resolution capability of FTICRMS was necessary to obtain an accurate mass due to contributions of the M(+.) (13)C isotope in the [M+H](+) ion peak.
Collapse
Affiliation(s)
- Michael J Greig
- Pfizer Global Research and Development, La Jolla Laboratories, San Diego, CA 92121, USA.
| | | | | | | |
Collapse
|
63
|
van Hout MWJ, Niederländer HAG, de Zeeuw RA, de Jong GJ. Ion suppression in the determination of clenbuterol in urine by solid-phase extraction atmospheric pressure chemical ionisation ion-trap mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2003; 17:245-250. [PMID: 12539191 DOI: 10.1002/rcm.908] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Ion suppression effects were observed during the determination of clenbuterol in urine with solid-phase extraction/multiple-stage ion-trap mass spectrometry (SPE/MS(3)), despite the use of atmospheric pressure chemical ionisation. During SPE, a polymeric stationary phase (polydivinylbenzene) was applied. Post-cartridge infusion of analyte to the SPE eluate after the extraction of blank urine was performed to obtain a profile of the suppression. Single and multiple-stage MS were performed to provide insight in the suppressing compounds. The ion suppression was mainly ascribed to two m/z values, but still no identification of the compounds was achieved from the multiple-stage MS data. No ionisable and non-ionisable complexes and/or precipitation of clenbuterol with matrix compounds were observed. A concentration dependence of the percentage of suppression was observed. Up to 70% of the signal was suppressed upon post-cartridge infusion of 0.22 microg/mL (at 5 microL/min) clenbuterol into the eluate, and this decreased to about 4% at infusion of 22 microg/mL clenbuterol. Molecularly imprinted polymers were used to enhance the selectivity of the extraction. Although matrix components were still present after extraction, no interference of these compounds with the analyte was observed. However, the bleeding of the imprint from the polymer (brombuterol) caused significant ion suppression.
Collapse
Affiliation(s)
- M W J van Hout
- Department of Analytical Chemistry and Toxicology, University Centre for Pharmacy, University of Groningen, A Deusinglaan 1, 9713 AV Groningen, The Netherlands.
| | | | | | | |
Collapse
|
64
|
Abstract
This review focuses on biological and biomedical mass spectrometry, and covers a selection of publications in this area included in the MEDLINE database for the period 1987-2001. Over the last 15 years, biological and biomedical mass spectrometry has progressed out of all recognition. The development of soft ionization methods, such as electrospray ionization and matrix-assisted laser desorption ionization, has mainly contributed to the remarkable progress, because they can easily produce gas-phase ions of large, polar, and thermally labile biomolecules, such as proteins, peptides, nucleic acids and others. The innovations of ionization methods have led to remarkable progress in mass spectrometric technology and in biochemistry, biotechnology and molecular biology research. In addition, mass spectrometry is one of the powerful and effective technologies for drug discovery and development. It is applicable to studies on structural determination, drug metabolism, including pharmacokinetics and toxicokinetics, and de novo drug discovery by applying post-genomic approarches. In the present review, the innovative soft ionization methods are first discussed along with their features. Also, the characteristics of the mass spectrometers which are active in the biological and biomedical research fields are also described. In addition, examples of the applications of biological and biomedical mass spectrometry are provided.
Collapse
Affiliation(s)
- Nariyasu Mano
- Graduate School of Pharmaceutical Sciences, Tohoku University, Aobayama, Sendai 980-8578, Japan.
| | | |
Collapse
|
65
|
Kuuranne T, Kotiaho T, Pedersen-Bjergaard S, Einar Rasmussen K, Leinonen A, Westwood S, Kostiainen R. Feasibility of a liquid-phase microextraction sample clean-up and liquid chromatographic/mass spectrometric screening method for selected anabolic steroid glucuronides in biological samples. JOURNAL OF MASS SPECTROMETRY : JMS 2003; 38:16-26. [PMID: 12526002 DOI: 10.1002/jms.393] [Citation(s) in RCA: 63] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Anabolic androgenic steroids (AAS) are metabolized extensively in the human body, resulting mainly in the formation of glucuronide conjugates. Current detection methods for AAS are based on gas chromatographic/mass spectrometric (GC/MS) analysis of the hydrolyzed steroid aglycones. These analyses require laborious sample preparation steps and are therefore time consuming. Our interest was to develop a rapid and straightforward method for intact steroid glucuronides in biological samples, using liquid-phase microextraction (LPME) sample clean-up and concentration method combined with liquid chromatographic/tandem mass spectrometric (LC/MS/MS) analysis. The applicability of LPME was optimized for 13 steroid glucuronides, and compared with conventional liquid-liquid extraction (LLE) and solid-phase extraction (SPE) procedures. An LC/MS/MS method was developed for the quantitative detection of AAS glucuronides, using a deuterium-labeled steroid glucuronide as the internal standard. LPME, owing to its high specificity, was shown to be better suited than conventional LLE and SPE for the clean-up of urinary AAS glucuronides. The LPME/LC/MS/MS method was fast and reliable, offering acceptable reproducibility and linearity with detection limits in the range 2-20 ng ml(-1) for most of the selected AAS glucuronides. The method was successfully applied to in vitro metabolic studies, and also tested with an authentic forensic urine sample. For a urine matrix the method still has some unsolved problems with specificity, which should be overcome before the method can be reliably used for doping analysis, but still offering additional and complementary data for current GC/MS analyses.
Collapse
Affiliation(s)
- Tiia Kuuranne
- Division of Pharmaceutical Chemistry, Department of Pharmacy, P.O. Box 56, 00014 University of Helsinki, Finland
| | | | | | | | | | | | | |
Collapse
|
66
|
Abstract
Steroid assays are important for medical diagnosis of diseases related to steroid disturbances and abuse. This article reviews the recent progress in analytical methods for steroids in the clinical laboratory. The requirements for these methods are rapid, highly sensitive, specific, direct assay of conjugated steroids, the simultaneous analysis, identification of unknown steroids, and ultra-miniaturization of the separation system.
Collapse
Affiliation(s)
- O Nozaki
- Department of Clinical Pathology, Kinki University School of Medicine, Osaka-Sayama, Japan
| |
Collapse
|
67
|
Shimada K, Mitamura K, Higashi T. Gas chromatography and high-performance liquid chromatography of natural steroids. J Chromatogr A 2001; 935:141-72. [PMID: 11762773 DOI: 10.1016/s0021-9673(01)00943-8] [Citation(s) in RCA: 124] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
This review article underlines the importance of gas chromatography (GC), high-performance liquid chromatography (HPLC) and their hyphenated techniques using mass spectrometry (MS) for the determination of natural steroids, especially in human biological fluids. Steroids are divided into eight categories based on their structures and functions, and recent references using the above methodologies for the analysis of these steroids are cited. GC and GC-MS are commonly used for the determination of volatile steroids. Although HPLC is a widely used analytical method for the determination of steroids including the conjugated type in biological fluids, LC-MS is considered to be the most promising one for this purpose because of its sensitivity, specificity and versatility.
Collapse
Affiliation(s)
- K Shimada
- Faculty of Pharmaceutical Sciences, Kanazawa University, Japan.
| | | | | |
Collapse
|
68
|
Thevis M, Opfermann G, Schmickler H, Schänzer W. Mass spectrometry of steroid glucuronide conjugates. I. Electron impact fragmentation of 5alpha-/5beta-androstan-3alpha-ol-17-one glucuronides, 5alpha-estran-3alpha-ol-17-one glucuronide and deuterium-labelled analogues. JOURNAL OF MASS SPECTROMETRY : JMS 2001; 36:159-168. [PMID: 11288198 DOI: 10.1002/jms.117] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Owing to the developments of analytical instruments and interfaces (e.g. coupling high-performance liquid chromatography to mass spectrometry), there has been increased interest in new reference materials, for example in doping analysis with steroid glucuronide conjugates. The synthesized reference material has to pass several characterization steps including the use of gas chromatography/mass spectrometry (GC/MS) for its structure confirmation. In the present study, the fragmentation and mass spectrometric behaviour of several steroid glucuronide conjugates of endogenous and anabolic steroids after derivatization to pertrimethylsilylated products and to methyl ester pertrimethylsilylated products were investigated using GC/MS ion trap and GC/MS quadrupole instruments. The mass spectra of the derivatives of androsterone glucuronide, d5-androsterone glucuronide, epiandrosterone glucuronide, etiocholanolone glucuronide, 11beta-hydroxy etiocholanolone glucuronide, 19-norandrosterone glucuronide, d4-19-norandrosterone glucuronide and 1alpha-methyl-5alpha-androstan-3alpha-ol-17-one glucuronide are presented and the origin of typical fragment ions of the glycosidic and steroidal moieties is proposed, based on different derivatization techniques including derivatization with d18-bistrimethylsilylacetamide, methyl ester and trimethylsilyl ester derivatization and selected reaction monitoring. Typical fragmentation patterns which are related to the steroid structure are discussed.
Collapse
Affiliation(s)
- M Thevis
- Institute of Biochemistry, German Sports University, Cologne, Germany.
| | | | | | | |
Collapse
|
69
|
Desiderio DM, Wirth U, Lovelace JL, Fridland G, Umstot ES, Nguyen TM, Schiller PW, Szeto HS, Clapp JF. Matrix-assisted laser desorption/ionization mass spectrometric quantification of the mu opioid receptor agonist DAMGO in ovine plasma. JOURNAL OF MASS SPECTROMETRY : JMS 2000; 35:725-733. [PMID: 10862125 DOI: 10.1002/1096-9888(200006)35:6<725::aid-jms1>3.0.co;2-i] [Citation(s) in RCA: 22] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
The synthetic opioid peptide analog Tyr-D-Ala-Gly-N-methyl-Phe-Gly-ol (DAMGO), which is a mu opioid receptor-selective agonist, was quantified in ovine plasma samples with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS), using delayed extraction and a reflectron. The internal standard was pentadeuterated DAMGO. Timed-ion selection was used to select the precursor ion. The analysis of the post-source decay fragments improved the detection sensitivity, and the use of the precursor-product ion relationship optimized the specificity. For plasma samples, the inter-assay variability of this method was 6.4% (n = 79) and the intra-assay variability was 6.0% (n = 10). The variability for controls was 3.4% (n = 43). The profile of DAMGO amount versus time was determined in sheep plasma, and the corresponding pharmacokinetic data were calculated.
Collapse
MESH Headings
- Analysis of Variance
- Animals
- Enkephalin, Ala(2)-MePhe(4)-Gly(5)-/administration & dosage
- Enkephalin, Ala(2)-MePhe(4)-Gly(5)-/blood
- Enkephalin, Ala(2)-MePhe(4)-Gly(5)-/pharmacokinetics
- Female
- Infusions, Intravenous
- Receptors, Opioid, mu/agonists
- Reference Standards
- Reproducibility of Results
- Sensitivity and Specificity
- Sheep
- Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods
- Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/standards
- Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/statistics & numerical data
Collapse
Affiliation(s)
- D M Desiderio
- Charles B. Stout Neuroscience Mass Spectrometry Laboratory, Departments of Neurology and Biochemistry, University of Tennessee, Memphis, 847 Monroe Avenue, Memphis, Tennessee 38163, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|