51
|
Lin Z, Zhang S, Zhao M, Yang C, Chen D, Zhang X. Rapid screening of clenbuterol in urine samples by desorption electrospray ionization tandem mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2008; 22:1882-8. [PMID: 18470868 DOI: 10.1002/rcm.3565] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Rapid screening of clenbuterol in urine was performed by combining desorption electrospray ionization (DESI) and tandem mass spectrometry (MS/MS). Optimization experiments were carried out including the selection of substrates, spray solutions, nebulizing gas pressures, high-voltage power supplies and flow rates of spray solution. The limit of detection (LOD), defined as the lowest quantity that can be detected, was 5.0 pg for the pure compound. Using DESI coupled with solid-phase extraction (SPE), the linear response range was from 10 to 400 ng/mL (R(2) = 0.993) and the concentration LOD for urine sample was 2.0 ng/mL. The analysis for one spiked urine sample was achieved within 4 min. In addition to the fast analysis speed, MS/MS provided structural information for the confirmation of clenbuterol. Urine samples from different people were investigated and the recoveries were within 100 +/- 20%. The developed method can potentially be used for screening of clenbuterol in doping control.
Collapse
Affiliation(s)
- Ziqing Lin
- Department of Chemistry, Tsinghua University, 100084 Beijing, People's Republic of China
| | | | | | | | | | | |
Collapse
|
52
|
Ventura R, Roig M, Montfort N, Sáez P, Bergés R, Segura J. High-throughput and sensitive screening by ultra-performance liquid chromatography tandem mass spectrometry of diuretics and other doping agents. EUROPEAN JOURNAL OF MASS SPECTROMETRY (CHICHESTER, ENGLAND) 2008; 14:191-200. [PMID: 18708699 DOI: 10.1255/ejms.920] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
The reliability of ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC- MS/MS) for high throughput screening in anti-doping control has been tested. A method to screen for the presence of diuretics and other doping agents in urine has been optimised and validated. The extraction procedure consisted of an alkaline extraction (pH 9.5) with ethyl acetate and salting-out effect (sodium chloride). The extracts were analysed by UPLC-MS/MS. Analysis of 34 forbidden drugs and metabolites was achieved in a total run time of 5 min, using a C18 column (100 mm x 2.1 mm i.d., 1.7 microm particle size) and a mobile phase containing deionised water and acetonitrile with formic acid, with gradient elution at a flow-rate of 0.6 mL min(-1). Identification of the compounds was performed by multiple reaction monitoring, using electrospray ionisation in positive- or negative-ion mode. Precursor and product ions were studied for each compound and cone voltage and collision energy were optimised. Due to the different chemical structure of the compounds under study, extraction recoveries varied from less than 10% to 100% depending on the analyte. The limits of detection ranged from 50 ng mL(-1) to 200 ng mL(-1), and all the compounds comply with the requirements of quality established by the World Anti-doping Agency. Intra-assay precision was evaluated at two concentrations for each compound and, in most cases, a relative standard deviation of the signal ratio lower than 20% was obtained. The method has demonstrated to be reliable when analysing routine samples and the short analysis time resulting from a simple sample preparation and a rapid instrumental analysis allow a fast turn-around time and makes it of great interest for routine anti-doping control purposes.
Collapse
Affiliation(s)
- Rosa Ventura
- Grup de Recerca en Bioanàlisis, IMIM-Hospital del Mar, Barcelona, Spain.
| | | | | | | | | | | |
Collapse
|
53
|
Reig M, Toldrá F. Veterinary drug residues in meat: Concerns and rapid methods for detection. Meat Sci 2008; 78:60-7. [DOI: 10.1016/j.meatsci.2007.07.029] [Citation(s) in RCA: 73] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2007] [Revised: 07/27/2007] [Accepted: 07/27/2007] [Indexed: 10/23/2022]
|
54
|
Reig M, Toldrá F. Liquid Chromatography for the Rapid Screening of Growth Promoters Residues in Meat. FOOD ANAL METHOD 2007. [DOI: 10.1007/s12161-007-9000-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
55
|
Thevis M, Schänzer W. Mass spectrometry in sports drug testing: Structure characterization and analytical assays. MASS SPECTROMETRY REVIEWS 2007; 26:79-107. [PMID: 16888758 DOI: 10.1002/mas.20107] [Citation(s) in RCA: 144] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Owing to the sensitive, selective, and unambiguous nature of mass spectrometric analyses, chromatographic techniques interfaced to various kinds of mass spectrometers have become the most frequently employed strategy in the fight against doping. To obtain utmost confidence in analytical assays, mass spectrometric characterization of target analytes and typical dissociation pathways have been utilized as basis for the development of reliable and robust screening as well as confirmation procedures. Methods for qualitative and/or quantitative determinations of prohibited low and high molecular weight drugs have been established in doping control laboratories preferably employing gas or liquid chromatography combined with electron, chemical, or atmospheric pressure ionization followed by analyses using quadrupole, ion trap, linear ion trap, or hyphenated techniques. The versatility of modern mass spectrometers enable specific as well as comprehensive measurements allowing sports drug testing laboratories to determine the misuse of therapeutics such as anabolic-androgenic steroids, stimulants, masking agents or so-called designer drugs in athletes' blood or urine specimens, and a selection of recent developments is summarized in this review.
Collapse
Affiliation(s)
- Mario Thevis
- Institute of Biochemistry and Center for Preventive Doping Research, German Sport University Cologne, Carl-Diem Weg 6, 50933 Cologne, Germany.
| | | |
Collapse
|
56
|
Thevis M, Sigmund G, Koch A, Schänzer W. Determination of tuaminoheptane in doping control urine samples. EUROPEAN JOURNAL OF MASS SPECTROMETRY (CHICHESTER, ENGLAND) 2007; 13:213-21. [PMID: 17881789 DOI: 10.1255/ejms.875] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Since January 2007, the list of prohibited substances established by the World Anti-Doping Agency includes the sympathomimetic compound tuaminoheptane (1-methyl-hexylamine, 2-heptylamine). Primarily used as nasal decongestant drug it has been considered relevant for sports drug testing due to its stimulating properties. A confirmatory gas chromatographic-mass spectrometric procedure was developed including liquid-liquid extraction and imine formation of tuaminoheptane employing various aldehydes and ketones such as formaldehyde, acetaldehyde, benzaldehyde and acetone. Extraction and derivatisation conditions were optimised for utmost efficiency, and characteristic fragment ions obtained after electron ionisation allowed for a sensitive and selective analytical assay, which was validated with regard to recovery (50%), lower limit of detection (20 ng mL(-1)) as well as interday- and intraday precision (<15%). The applicability to authentic urine samples was demonstrated using administration study specimens obtained from two male persons using Rhinofluimucil (tuaminoheptane hemisulfate) for intranasal application. The administered drug was detected up to 46 h after repeated topical instillation of a total of approximately 3 mg.
Collapse
Affiliation(s)
- Mario Thevis
- Center for Preventive Doping Research-Institute of Biochemistry, German Sport University Cologne, Carl-Diem Weg 6, 50933 Cologne, Germany.
| | | | | | | |
Collapse
|
57
|
Kang MJ, Hwang YH, Lee W, Kim DH. Validation and application of a screening method for beta2-agonists, anti-estrogenic substances and mesocarb in human urine using liquid chromatography/tandem mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2007; 21:252-64. [PMID: 17171780 DOI: 10.1002/rcm.2834] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
Electrospray ionization (ESI) mass spectra of 15 anti-estrogenic substances, beta2-agonists and mesocarb were investigated in terms of fragmentation patterns. On the basis of this product ion information, a simultaneous screening method for anti-estrogenic substances, beta2-agonists and mesocarb was developed for doping control purposes. After hydrolysis, liquid-liquid extraction was adopted for the sample preparation. The recoveries for all compounds were 30 and 96%. A single liquid chromatography/tandem mass spectrometry (LC/MS/MS) analysis could be performed in 13 min for the analysis of 15 anti-estrogenic substances, beta2-agonists and mesocarb. A quantitative analysis was also validated. Inaccuracies were below +/-12% and precisions varied from 0 to 15.8%. The limit of detection was below 10 ng/mL except formestane (300 ng/mL) and aminoglutethimide (100 ng/mL). The validated method was applied for the analysis of excretion samples.
Collapse
Affiliation(s)
- Min-Jung Kang
- Bioanalysis & Biotransformation Center, Korea Institute of Science and Technology, 130-650, Hawolgokdong 39-1, Seoul, Korea.
| | | | | | | |
Collapse
|
58
|
Yamini Y, Reimann CT, Vatanara A, Jönsson JA. Extraction and preconcentration of salbutamol and terbutaline from aqueous samples using hollow fiber supported liquid membrane containing anionic carrier. J Chromatogr A 2006; 1124:57-67. [PMID: 16716341 DOI: 10.1016/j.chroma.2006.05.001] [Citation(s) in RCA: 90] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2006] [Revised: 04/29/2006] [Accepted: 05/01/2006] [Indexed: 11/26/2022]
Abstract
This paper presents a new three-phase liquid-phase microextraction (LPME) strategy for extraction and preconcentration of salbutamol (SB) and terbutaline (TB) from aqueous samples, including urine. The drugs were extracted from 11 ml of aqueous sample (source phase; SP) into an organic phase with microliter volume located inside the pores of a polypropylene hollow fiber, and then back-extracted into 24 microl of a second aqueous solution as the receiving phase (RP), located in the lumen of the hollow fiber. In preliminary experiments, we tried to transport the drugs using a pH gradient between the two sides of the hollow fiber. Due to the existence of both amine and phenolic groups on the drugs, very little transport occurred and enrichment factors (EF) less than one were obtained. Further experiments were done in the presence of bis(2-ethylhexyl) monohydrogenphosphoric acid (D2EHPA) or methyltrioctylammonium chloride (Aliquat 336) in the organic phase, to extract drugs from acidic and basic matrices, respectively. Results showed that transport of drugs from alkaline solution into 1M of sodium bromide occurred when the membrane was impregnated with dihexyl ether containing 20% Aliquat 336. To optimize the EF, the effects of different parameters such as the nature of organic solvent used to impregnate the membrane, compositions and volumes of SP and RP, type and concentration of carrier, extraction time and stirring rate were investigated. Optimal results were obtained in the presence of 0.005 M of NaOH (pH 11.70) in the SP, 1M of NaBr in the RP, 20% of Aliquat 336 in dihexyl ether as membrane impregnation solvent, stirring rate of 500 rpm and extraction time of 60 min. Under these conditions, enrichment factors of 52.9 and 213.1, dynamic linear ranges of 20-5000 and 10-5000, and limits of detection of 2.5 and 0.5 ng/ml were obtained for salbutamol and terbutaline, respectively. Also determination of drugs in environmental water and urine samples in the range of nanograms per millilitre with RSDs<10% was possible using HPLC-photodiode array detection or HPLC-MS.
Collapse
Affiliation(s)
- Yadollah Yamini
- Department of Chemistry, Tarbiat Modarres University, P.O. Box 11415-175, Tehran, Iran
| | | | | | | |
Collapse
|
59
|
Thevis M, Sigmund G, Schiffer AK, Schänzer W. Determination of N-desmethyl- and N-bisdesmethyl metabolites of Sibutramine in doping control analysis using liquid chromatography-tandem mass spectrometry. EUROPEAN JOURNAL OF MASS SPECTROMETRY (CHICHESTER, ENGLAND) 2006; 12:129-36. [PMID: 16723754 DOI: 10.1255/ejms.797] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Since January 2006, the list of prohibited substances established by the World Anti-Doping Agency includes the antidepressant / anti-obesity drug Sibutramine. Due to its rapid degradation to its active metabolites N-desmethyl and N-bisdesmethyl Sibutramine, reference compounds were synthesized and included into an existing screening assay to allow the unambiguous determination of these metabolic products in human urine using liquid-liquid extraction followed by liquid chromatography/tandem mass spectrometry. Characteristic product ions, obtained after electrospray ionization and collision-induced dissociation, were elucidated using high resolution/high accuracy mass measurements with a hybrid linear ion trap/orbitrap mass analyzer. Based on diagnostic product ions, the extended screening procedure was validated for both Sibutramine metabolites using a triple quadrupole mass spectrometer. Items such as lower limits of detection (6-40 ng mL(-1)), recoveries (39-42%), intraday precision (low: 5.5-10.6%, medium: 4.9-5.9%), high: 12.8-16.4%) and interday precision (low: 15.0-22.8%, medium: 17.7-18.6%), high: 16.5-25.6%) were evaluated, and a clinical spot urine sample was analyzed to demonstrate the applicability of the developed assay in sports drug testing.
Collapse
Affiliation(s)
- Mario Thevis
- Institute of Biochemistry and Center for Preventive Doping Research, German Sport University Cologne, Carl-Diem Weg 6, 50933 Cologne, Germany.
| | | | | | | |
Collapse
|
60
|
Thevis M, Schebalkin T, Thomas A, Schänzer W. Quantification of Clenbuterol in Human Plasma and Urine by Liquid Chromatography-Tandem Mass Spectrometry. Chromatographia 2005. [DOI: 10.1365/s10337-005-0651-3] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
61
|
Thevis M, Bommerich U, Opfermann G, Schänzer W. Characterization of chemically modified steroids for doping control purposes by electrospray ionization tandem mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2005; 40:494-502. [PMID: 15712346 DOI: 10.1002/jms.820] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
The discovery of the designer steroid tetrahydrogestrinone (THG) in elite athletes' doping control samples in 2003 demonstrated the availability of steroid derivatives prepared solely for doping purposes. Modern mass spectrometers utilizing electrospray ionization and collisionally activated dissociation (CAD) of analytes allow the structural characterization of steroids and their derivatization sites by the elucidation of fragmentation behaviors. A total of 21 steroids comprising either a 4,9,11-triene, a 3-keto-4-ene or a 3-keto-1-ene nucleus were investigated regarding their dissociation pathways, deuterated analogues were synthesized and fragmentation routes were postulated, permitting the identification of steroidal structures and modifications. Compounds based on a 4,9,11-triene steroid with an ethyl residue at C-13 (gestrinone analogues) generate abundant fragment ions at m/z 241 and 199, whereas the substitution of the C-13 ethyl group by a methyl residue (trenbolone analogues) results in a shift of m/z 241 to 227. Substances related to testosterone with a 3-keto-4-ene structure give rise to abundant fragment ions at m/z 109 and 97 whereas steroids with a 3-keto-1-ene nucleus eliminate the A-ring including the carbons C-1-C-4, in addition to C-19 that is proposed to migrate from C-10 to C-1 under CAD conditions.
Collapse
Affiliation(s)
- Mario Thevis
- Institute of Biochemistry, German Sport University Cologne, Carl-Diem Weg 6, 50933 Cologne, Germany.
| | | | | | | |
Collapse
|
62
|
Yuen AHY, Yacoub MH, Smolenski RT. Determination of clenbuterol concentration in human blood using liquid chromatography with electrospray/ion-trap tandem mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2005; 19:3603-6. [PMID: 16276488 DOI: 10.1002/rcm.2211] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
|
63
|
Maurer HH. Position of chromatographic techniques in screening for detection of drugs or poisons in clinical and forensic toxicology and/or doping control. ACTA ACUST UNITED AC 2004; 42:1310-24. [PMID: 15576292 DOI: 10.1515/cclm.2004.250] [Citation(s) in RCA: 120] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
AbstractThis paper reviews chromatographic screening procedures for simultaneous detection of several drug classes relevant to clinical and forensic toxicology or doping control in urine or blood using gas chromatography-mass spectrometry (GC-MS), liquid chromatography coupled with a diode-array detector (LC-DAD) or a mass spectrometer (LC-MS). The pros and cons of the different techniques and procedures are discussed leading to the following conclusions and perspectives. GC-MS, especially in the electron ionization full-scan mode, is still the method of choice for comprehensive screening providing best separation power, specificity and universality, although requiring derivatization. LC-DAD is also often used for screening, but its separation power and its specificity are still inferior to those of GC-MS. Finally, LC-MS has shown to be an ideal supplement, especially for the detection of more polar, thermolabile and/or low-dose drugs, especially in blood plasma. It may become the gold standard in clinical and forensic toxicology and doping control if, at a later date, the costs of the apparatus will be markedly reduced, the current disadvantages like irreproducibility of fragmentation, reduction of ionization by matrix, etc. will be overcome, and finally if one of the increasing number of quite different techniques will become the apparatus standard.
Collapse
Affiliation(s)
- Hans H Maurer
- Department of Experimental and Clinical Toxicology, Institute of Experimental and Clinical Pharmacology and Toxicology, University of Saarland, Homburg (Saar), Germany.
| |
Collapse
|