51
|
Bavaria JE, Tommaso CL, Brindis RG, Carroll JD, Deeb GM, Feldman TE, Gleason TG, Horlick EM, Kavinsky CJ, Kumbhani DJ, Miller DC, Seals AA, Shahian DM, Shemin RJ, Sundt TM, Thourani VH. 2018 AATS/ACC/SCAI/STS Expert Consensus Systems of Care Document: Operator and institutional recommendations and requirements for transcatheter aortic valve replacement. J Thorac Cardiovasc Surg 2019; 157:e77-e111. [DOI: 10.1016/j.jtcvs.2018.07.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
52
|
Karciauskas D, Mizariene V, Jakuska P, Ereminiene E, Orda P, Ordiene R, Vaskelyte JJ, Nedzelskiene I, Kinduris S, Benetis R. Early and long-term results of aortic valve sparing aortic root reimplantation surgery for bicuspid and tricuspid aortic valves. Perfusion 2019; 34:482-489. [DOI: 10.1177/0267659119831926] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Introduction: To evaluate early and long-term clinical outcomes following aortic valve sparing aortic root reimplantation surgery in patients with leaking bicuspid and tricuspid aortic valves. Methods: The study consisted of 92 consecutive adult patients (tricuspid aortic valve group = 63 and bicuspid aortic valve group = 29) who underwent aortic valve sparing aortic root reimplantation surgery with or without aortic cusp repair for dilatation of the aortic root and/or aortic valve regurgitation at our institution from April 2004 to October 2016. Clinical outcomes were investigated using Kaplan–Meier and log-rank tests between groups. Results: The follow-up was 100% complete with a mean time of 5.3 ± 3.3 years. The 30-day in-hospital mortality was 3.1% in tricuspid aortic valve group and 3.4% in bicuspid aortic valve group patients. The overall survival rates at 10 years did not differ between bicuspid aortic valve and tricuspid aortic valve patient groups (96.6 ± 3.3% vs. 90.3 ± 4.2%, p = 0.3). Freedom from recurrent aortic valve regurgitation (>2+) at 10 years was 90.5 ± 4.1% in tricuspid aortic valve group and 75.7 ± 8.7% in bicuspid aortic valve group (p = 0.06). Freedom from aortic valve reoperation at 10 years was 100% in tricuspid aortic valve group and 83.9 ± 7.4% in bicuspid aortic valve group (p = 0.002). Conclusion: Aortic valve sparing aortic root reimplantation surgery is a safe and efficient technique, providing acceptable long-term survival with low rates of valve-related complications in both tricuspid aortic valve and bicuspid aortic valve patient groups. However, aortic valve reoperation rates at 10 years follow-up were higher in bicuspid aortic valve group patients compared to tricuspid aortic valve group patients.
Collapse
Affiliation(s)
- Dainius Karciauskas
- Department of Cardiac, Thoracic and Vascular Surgery, Hospital of Lithuanian University of Health Sciences Kauno Klinikos, Medical Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Vaida Mizariene
- Department of Cardiology, Medical Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Povilas Jakuska
- Department of Cardiac, Thoracic and Vascular Surgery, Hospital of Lithuanian University of Health Sciences Kauno Klinikos, Medical Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Egle Ereminiene
- Department of Cardiology, Medical Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Paulius Orda
- Department of Cardiology, Medical Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Rasa Ordiene
- Department of Cardiology, Medical Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Jolanta Justina Vaskelyte
- Department of Cardiology, Medical Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Irena Nedzelskiene
- Department of Dental and Oral Diseases, Medical Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Sarunas Kinduris
- Department of Cardiac, Thoracic and Vascular Surgery, Hospital of Lithuanian University of Health Sciences Kauno Klinikos, Medical Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Rimantas Benetis
- Department of Cardiac, Thoracic and Vascular Surgery, Hospital of Lithuanian University of Health Sciences Kauno Klinikos, Medical Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
| |
Collapse
|
53
|
Etnel JR, Huygens SA, Grashuis P, Pekbay B, Papageorgiou G, Roos Hesselink JW, Bogers AJ, Takkenberg JJ. Bioprosthetic Aortic Valve Replacement in Nonelderly Adults. Circ Cardiovasc Qual Outcomes 2019; 12:e005481. [DOI: 10.1161/circoutcomes.118.005481] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Affiliation(s)
- Jonathan R.G. Etnel
- Department of Cardiothoracic Surgery (J.R.G.E., S.A.H., P.G., B.P., G.P., A.J.J.C.B., J.J.M.T.), Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Simone A. Huygens
- Department of Cardiothoracic Surgery (J.R.G.E., S.A.H., P.G., B.P., G.P., A.J.J.C.B., J.J.M.T.), Erasmus University Medical Center, Rotterdam, The Netherlands
- Erasmus School of Health Policy & Management, Erasmus University Rotterdam, Rotterdam, The Netherlands (S.A.H.)
| | - Pepijn Grashuis
- Department of Cardiothoracic Surgery (J.R.G.E., S.A.H., P.G., B.P., G.P., A.J.J.C.B., J.J.M.T.), Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Begüm. Pekbay
- Department of Cardiothoracic Surgery (J.R.G.E., S.A.H., P.G., B.P., G.P., A.J.J.C.B., J.J.M.T.), Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Grigorios Papageorgiou
- Department of Cardiothoracic Surgery (J.R.G.E., S.A.H., P.G., B.P., G.P., A.J.J.C.B., J.J.M.T.), Erasmus University Medical Center, Rotterdam, The Netherlands
- Department of Biostatistics (G.P.), Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Jolien W. Roos Hesselink
- Department of Cardiology (J.W.R.H.), Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Ad J.J.C. Bogers
- Department of Cardiothoracic Surgery (J.R.G.E., S.A.H., P.G., B.P., G.P., A.J.J.C.B., J.J.M.T.), Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Johanna J.M. Takkenberg
- Department of Cardiothoracic Surgery (J.R.G.E., S.A.H., P.G., B.P., G.P., A.J.J.C.B., J.J.M.T.), Erasmus University Medical Center, Rotterdam, The Netherlands
| |
Collapse
|
54
|
Heinisch PP, Carrel T. Commentary: Tissue valves in younger patients: Hazardous developments on the horizon. J Thorac Cardiovasc Surg 2019; 158:46-47. [PMID: 30685169 DOI: 10.1016/j.jtcvs.2018.12.038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/13/2018] [Accepted: 12/14/2018] [Indexed: 11/17/2022]
Affiliation(s)
- Paul Philipp Heinisch
- Department of Cardiovascular Surgery, Inselspital, University Hospital, University of Bern, Bern, Switzerland
| | - Thierry Carrel
- Department of Cardiovascular Surgery, Inselspital, University Hospital, University of Bern, Bern, Switzerland.
| |
Collapse
|
55
|
Bavaria JE, Tommaso CL, Brindis RG, Carroll JD, Michael Deeb G, Feldman TE, Gleason TG, Horlick EM, Kavinsky CJ, Kumbhani DJ, Craig Miller D, Allen Seals A, Shahian DM, Shemin RJ, Sundt TM, Thourani VH. 2018 AATS/ACC/SCAI/STS expert consensus systems of care document: Operator and institutional recommendations and requirements for transcatheter aortic valve replacement. Catheter Cardiovasc Interv 2019; 93:E153-E184. [DOI: 10.1002/ccd.27811] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/29/2017] [Accepted: 06/10/2018] [Indexed: 11/10/2022]
Affiliation(s)
| | - Carl L. Tommaso
- Society for Cardiovascular Angiography and Interventions Representative
| | | | | | | | - Ted E. Feldman
- Society for Cardiovascular Angiography and Interventions Representative
| | | | - Eric M. Horlick
- Society for Cardiovascular Angiography and Interventions Representative
| | | | | | | | | | | | | | | | | |
Collapse
|
56
|
Bavaria JE, Tommaso CL, Brindis RG, Carroll JD, Deeb GM, Feldman TE, Gleason TG, Horlick EM, Kavinsky CJ, Kumbhani DJ, Miller DC, Seals AA, Shahian DM, Shemin RJ, Sundt TM, Thourani VH. 2018 AATS/ACC/SCAI/STS Expert Consensus Systems of Care Document: Operator and Institutional Recommendations and Requirements for Transcatheter Aortic Valve Replacement. J Am Coll Cardiol 2019; 73:340-374. [DOI: 10.1016/j.jacc.2018.07.002] [Citation(s) in RCA: 65] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
57
|
Aasbjerg K, Mortensen PE, Nørgaard MA, Rytgaard HC, Gerds TA, Søgaard P, Torp-Pedersen C, Mortensen RN, Bagge BJ, Køber L, Nielsen PH. Comparison of Survival After Aortic Valve Replacement With Mitroflow or Perimount Prostheses. Semin Thorac Cardiovasc Surg 2019; 31:350-358. [DOI: 10.1053/j.semtcvs.2018.11.016] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2018] [Accepted: 11/30/2018] [Indexed: 11/11/2022]
|
58
|
Mazine A, El-Hamamsy I, Verma S, Peterson MD, Bonow RO, Yacoub MH, David TE, Bhatt DL. Ross Procedure in Adults for Cardiologists and Cardiac Surgeons. J Am Coll Cardiol 2018; 72:2761-2777. [DOI: 10.1016/j.jacc.2018.08.2200] [Citation(s) in RCA: 92] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/06/2018] [Accepted: 08/19/2018] [Indexed: 01/07/2023]
|
59
|
Complementary Role of the Computed Biomodelling through Finite Element Analysis and Computed Tomography for Diagnosis of Transcatheter Heart Valve Thrombosis. BIOMED RESEARCH INTERNATIONAL 2018; 2018:1346308. [PMID: 30426001 PMCID: PMC6217904 DOI: 10.1155/2018/1346308] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/24/2018] [Revised: 09/04/2018] [Accepted: 10/02/2018] [Indexed: 11/24/2022]
Abstract
Introduction The TAVR procedure is associated with a substantial risk of thrombosis. Current guidelines recommend catheter-based aortic valve implantation for prohibitive-high-risk patients with severe aortic valve stenosis but acknowledge that the aetiology and mechanism of thrombosis are unclear. Methods From 2015 to 2018, 607 patients with severe aortic valve stenosis underwent either self-expandable or balloon-expandable catheter-based aortic valve implantation at our institute. A complementary study was designed to support computed tomography as a predictor of complications using an advanced biomodelling process through finite element analysis (FEA). The primary evaluation of study was the thrombosis of the valve at 12 months. Results At 12 months, 546 patients had normal valvular function. 61 patients had THVT while 6 showed thrombosis and dislodgement with deterioration to NYHA Class IV requiring rehospitalization. The FEA biomodelling revealed a strong link between solid uncrushed calcifications, delayed dislodgement of TAVR and late thrombosis. We observed an interesting phenomenon of fibrosis/calcification originating at the level of the misplaced valve, which was the primary cause of coronary obstruction. Conclusion The use of cardiac CT and predictive biomodelling should be integrated into routine practice for the selection of TAVR candidates and as a predictor of negative outcomes given the lack of accurate investigations available. This would assist in effective decision-making and diagnosis especially in a high-risk cohort of patients.
Collapse
|
60
|
A Non-Invasive Material Characterization Framework for Bioprosthetic Heart Valves. Ann Biomed Eng 2018; 47:97-112. [PMID: 30229500 DOI: 10.1007/s10439-018-02129-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2018] [Accepted: 09/11/2018] [Indexed: 10/28/2022]
Abstract
Computational modeling and simulation has become more common in design and development of bioprosthetic heart valves. To have a reliable computational model, considering accurate mechanical properties of biological soft tissue is one of the most important steps. The goal of this study was to present a non-invasive material characterization framework to determine mechanical propertied of soft tissue employed in bioprosthetic heart valves. Using integrated experimental methods (i.e., digital image correlation measurements and hemodynamic testing in a pulse duplicator system) and numerical methods (i.e., finite element modeling and optimization), three-dimensional anisotropic mechanical properties of leaflets used in two commercially available transcatheter aortic valves (i.e., Edwards SAPIEN 3 and Medtronic CoreValve) were characterized and compared to that of a commonly used and well-examined surgical bioprosthesis (i.e., Carpentier-Edwards PERIMOUNT Magna aortic heart valve). The results of the simulations showed that the highest stress value during one cardiac cycle was at the peak of systole in the three bioprostheses. In addition, in the diastole, the peak of maximum in-plane principal stress was 0.98, 0.96, and 2.95 MPa for the PERIMOUNT Magna, CoreValve, and SAPIEN 3, respectively. Considering leaflet stress distributions, there might be a difference in the long-term durability of different TAV models.
Collapse
|
61
|
2018 AATS/ACC/SCAI/STS Expert Consensus Systems of Care Document: Operator and Institutional Recommendations and Requirements for Transcatheter Aortic Valve Replacement: A Joint Report of the American Association for Thoracic Surgery, American College of Cardiology, Society for Cardiovascular Angiography and Interventions, and The Society of Thoracic Surgeons. Ann Thorac Surg 2018; 107:650-684. [PMID: 30030976 DOI: 10.1016/j.athoracsur.2018.07.001] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/06/2018] [Accepted: 07/06/2018] [Indexed: 11/22/2022]
|
62
|
Abbasi M, Qiu D, Behnam Y, Dvir D, Clary C, Azadani AN. High resolution three-dimensional strain mapping of bioprosthetic heart valves using digital image correlation. J Biomech 2018; 76:27-34. [PMID: 29807762 PMCID: PMC9910203 DOI: 10.1016/j.jbiomech.2018.05.020] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2017] [Revised: 05/10/2018] [Accepted: 05/10/2018] [Indexed: 12/27/2022]
Abstract
Transcatheter aortic valve replacement (TAVR) is a safe and effective treatment option for patients deemed at high and intermediate risk for surgical aortic valve replacement. Similar to surgical aortic valves (SAVs), transcatheter aortic valves (TAVs) undergo calcification and mechanical wear over time. However, to date, there have been limited publications on the long-term durability of TAV devices. To assess longevity and mechanical strength of TAVs in comparison to surgical bioprosthetic valves, three-dimensional deformation analysis and strain measurement of the leaflets become an inevitable part of the evaluation. The goal of this study was to measure and compare leaflet displacement and strain of two commonly used TAVs in a side-by-side comparison with a commonly used SAV using a high-resolution digital image correlation (DIC) system. 26-mm Edwards SAPIEN 3, 26-mm Medtronic CoreValve, and 25-mm Carpentier-Edwards PERIMOUNT Magna surgical bioprosthesis were examined in a custom-made valve testing apparatus. A time-varying, spatially uniform pressure was applied to the leaflets at different loading rates. GOM ARAMIS® software was used to map leaflet displacement and strain fields during loading and unloading. High displacement regions were found to be at the leaflet belly region of the three bioprosthetic valves. In addition, the frame of the surgical bioprosthesis was found to be remarkably flexible, in contrary to CoreValve and SAPIEN 3 in which the stent was nearly rigid under a similar loading condition. The experimental DIC measurements can be used to characterize the anisotropic materiel behavior of the bioprosthetic heart valve leaflets and validate heart valve computational simulations.
Collapse
Affiliation(s)
| | - Dong Qiu
- University of Denver, Denver, CO, USA
| | | | - Danny Dvir
- University of Washington, Seattle, WA, USA
| | | | - Ali N. Azadani
- University of Denver, Denver, CO, USA,Corresponding author at: The DU Cardiovascular Biomechanics Laboratory, Department of Mechanical and Materials Engineering, 2155 E. Wesley Ave, Room 439, Denver, CO 80208, USA. (A.N. Azadani)
| |
Collapse
|
63
|
Zannis K, Diplaris K, Monin JL, Khelil N, Debauchez M, Dervanian P, Lansac E, Czirom D, Noghin M, Mankoubi L, Amabile N. Mitroflow LXA structural deterioration following aortic valve replacement: a single-center experience. THE JOURNAL OF CARDIOVASCULAR SURGERY 2018; 59:746-752. [PMID: 29786406 DOI: 10.23736/s0021-9509.18.10204-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND Concerns have been previously raised regarding the potential early degeneration of the Mitroflow (Sorin Group Italia, Saluggia, Vercelli, Italy) bioprostheses. We aimed to evaluate our clinical experience with the Mitroflow LXA prosthesis for aortic valve replacement. METHODS We prospectively analyzed data from 227 consecutive patients (133 males, mean age 73.9±9.2 years) implanted with the Mitroflow LXA between February 2007 and October 2011. Follow-up data were obtained by contacting the referring cardiologists. Kaplan-Meier curves were constructed for all-cause mortality, valve related mortality and structural valve degeneration (SVD). Multivariable analysis was conducted to identify SVD predictors. RESULTS Median follow-up time was 54.2±37.9 months and completeness of follow-up was 95%. Overall mortality in the entire series was at 31% (N.=71) and mortality from cardiac or unknown causes at 20% (N.=46). SVD occurred in 24 patients (10%) (median delay between implantation and diagnosis: 62.6 (36.5) months). Reintervention was required in 20 cases (13 redo surgery, 7 percutaneous transcatheter valve intervention). The 8 years actuarial global survival was 54.7±4.9%, freedom from valve related mortality 67.5±4.9% and freedom from SVD 72±8%. The estimated freedom from SVD was significantly (P=0.007) longer in larger prosthesis (diameter >21 mm, 77±11%) compared to the smaller devices (≤21 mm, 59±13%.). Multivariate analysis identified smaller prostheses and age at implantation as independent predictors of SVD. CONCLUSIONS The Mitroflow LXA showed evidence of early SVD in this cohort. A close follow-up of these patients is strongly advised.
Collapse
|
64
|
Nappi F, Nenna A, Petitti T, Spadaccio C, Gambardella I, Lusini M, Chello M, Acar C. Long-term outcome of cryopreserved allograft for aortic valve replacement. J Thorac Cardiovasc Surg 2018; 156:1357-1365.e6. [PMID: 29759737 DOI: 10.1016/j.jtcvs.2018.04.040] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/07/2017] [Revised: 02/12/2018] [Accepted: 04/02/2018] [Indexed: 10/17/2022]
Abstract
OBJECTIVE The most efficient surgical approach to severe aortic valve disease in the young adult is still debated: cryopreserved aortic allograft offers excellent hemodynamic and avoid anticoagulation, but long-term durability is influenced by structural valve deterioration (SVD). This study aimed to describe long-term results of aortic allografts and to identify factors influencing long-term durability. METHODS From January 1993 to August 2010, 210 patients underwent aortic allograft replacement via the free-hand subcoronary implantation technique (N = 55) or root replacement with coronary reimplantation (N = 155). Clinic and echocardiographic follow-up was updated to April 2016. RESULTS Overall mortality and cardiac mortality occurred in 80 (38.1%) and 64 (30.5%) patients, respectively. Reoperation was required in 69 cases (32.8%), whereas SVD required reoperation in 57 cases (27.1%). No early endocarditis occurred, whereas late endocarditis occurred in 4 patients. The free-hand technique seems to be associated with improved left ventricular remodeling compared with the root-replacement technique, and smaller allograft size represents a predictor of reoperation independently on the surgical technique used. In the overall population, there were 44 women of childbearing age, and 37 patients remained pregnant during the follow-up of the study. No differences were found in the clinical outcomes among women who had children and who did not. CONCLUSIONS Cryopreserved allograft is a valid option, especially in complex infective endocarditis and in women of childbearing age. A careful choice of allograft size and implantation technique can reduce the risk of SVD.
Collapse
Affiliation(s)
- Francesco Nappi
- Department of Cardiac Surgery, Centre Cardiologique du Nord de Saint-Denis, Paris, France.
| | - Antonio Nenna
- Department of Cardiovascular Surgery, Università Campus Bio-Medico di Roma, Rome, Italy
| | - Tommasangelo Petitti
- Department of Public Health and Statistics, Università Campus Bio-Medico di Roma, Rome, Italy
| | - Cristiano Spadaccio
- Department of Cardiothoracic Surgery, Golden Jubilee National Hospital, Glasgow, United Kingdom; University of Glasgow Institute of Cardiovascular and Medical Sciences, Glasgow, United Kingdom
| | - Ivancarmine Gambardella
- Department of Cardiac Surgery, Liverpool Heart and Chest Hospital, Liverpool, United Kingdom
| | - Mario Lusini
- Department of Cardiovascular Surgery, Università Campus Bio-Medico di Roma, Rome, Italy
| | - Massimo Chello
- Department of Cardiovascular Surgery, Università Campus Bio-Medico di Roma, Rome, Italy
| | - Christophe Acar
- Department of Cardiac Surgery, Hopital La Pitie Salpetriere, Paris, France
| |
Collapse
|
65
|
Rodriguez-Gabella T, Voisine P, Dagenais F, Mohammadi S, Perron J, Dumont E, Puri R, Asmarats L, Côté M, Bergeron S, Pibarot P, Rodés-Cabau J. Long-Term Outcomes Following Surgical Aortic Bioprosthesis Implantation. J Am Coll Cardiol 2018; 71:1401-1412. [DOI: 10.1016/j.jacc.2018.01.059] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2017] [Revised: 01/20/2018] [Accepted: 01/22/2018] [Indexed: 10/17/2022]
|
66
|
A heart valve is no stronger than its weakest link: The need to improve durability of pericardial leaflets. J Thorac Cardiovasc Surg 2018; 156:207-208. [PMID: 29636190 DOI: 10.1016/j.jtcvs.2018.03.034] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2018] [Accepted: 03/07/2018] [Indexed: 11/24/2022]
|
67
|
Stock S, Sievers HH, Richardt D, Scharfschwerdt M. Mitral valve replacement with the novel TRIBIO and an established stented bioprosthesis in a sheep model. Interact Cardiovasc Thorac Surg 2018; 26:438-442. [PMID: 29149268 DOI: 10.1093/icvts/ivx361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2017] [Accepted: 10/06/2017] [Indexed: 11/14/2022] Open
Abstract
OBJECTIVES Heart valve replacement with a bioprosthesis is one of the most frequently performed procedures in cardiac surgery and represents a highly effective therapy to relieve diseased heart valves. Nevertheless, as postoperatively elevated transvalvular gradients and prosthesis-patient mismatch are reported as shortcomings of the procedure or of the currently used devices, there is a need for novel bioprostheses with improved haemodynamics. This study presents preclinical haemodynamic results after mitral valve replacement with the novel TRIBIO bioprosthesis (TRIBIO) compared with an established bioprosthesis in a sheep model. METHODS Six female sheep had their mitral valves replaced with the TRIBIO and 3 with the Carpentier-Edwards Perimount, both sized 19 mm. The TRIBIO consists of a flexible valve-bearing crown, a force-decoupled interface and an intra-annular base ring. Mean and peak transvalvular gradients as well as an effective orifice area were monitored in both groups using transthoracic echocardiography over the course of the 90-day study. RESULTS In both groups, haemodynamic performance diminished over time. The TRIBIO demonstrated overall superior haemodynamics, i.e. lower transvalvular gradients and a larger effective orifice area, although the results were not statistically significant. On Day 90, the mean values for the mean and peak transvalvular gradients and the effective orifice area were 6 mmHg, 10.2 mmHg and 1.2 cm2 for the TRIBIO and 10 mmHg, 15.8 mmHg and 0.8 cm2 for the Carpentier-Edwards Perimount, respectively. CONCLUSIONS This study demonstrates a trend towards improved preclinical haemodynamic performance following mitral valve replacement with the TRIBIO compared to that with an established bioprosthesis in a sheep model.
Collapse
Affiliation(s)
- Sina Stock
- Department of Cardiac and Thoracic Vascular Surgery, University of Luebeck, Luebeck, Germany
| | - Hans-Hinrich Sievers
- Department of Cardiac and Thoracic Vascular Surgery, University of Luebeck, Luebeck, Germany
| | - Doreen Richardt
- Department of Cardiac and Thoracic Vascular Surgery, University of Luebeck, Luebeck, Germany
| | - Michael Scharfschwerdt
- Department of Cardiac and Thoracic Vascular Surgery, University of Luebeck, Luebeck, Germany
| |
Collapse
|
68
|
Rieß FC, Fradet G, Lavoie A, Legget M. Long-Term Outcomes of the Mosaic Bioprosthesis. Ann Thorac Surg 2018; 105:763-769. [DOI: 10.1016/j.athoracsur.2017.09.053] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2016] [Revised: 08/04/2017] [Accepted: 09/25/2017] [Indexed: 10/18/2022]
|
69
|
Mazine A, Ghoneim A, El-Hamamsy I. The Ross Procedure: How I Teach It. Ann Thorac Surg 2018; 105:1294-1298. [PMID: 29481789 DOI: 10.1016/j.athoracsur.2018.01.048] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/25/2017] [Revised: 01/25/2018] [Accepted: 01/25/2018] [Indexed: 11/18/2022]
Affiliation(s)
- Amine Mazine
- Division of Cardiac Surgery, Montreal Heart Institute, Université de Montréal, Montreal, Quebec, Canada
| | - Aly Ghoneim
- Division of Cardiac Surgery, Montreal Heart Institute, Université de Montréal, Montreal, Quebec, Canada
| | - Ismail El-Hamamsy
- Division of Cardiac Surgery, Montreal Heart Institute, Université de Montréal, Montreal, Quebec, Canada.
| |
Collapse
|
70
|
Stefanelli G, Pirro F, Olaru A, Danniballe G, Labia C, Weltert L. Long-term outcomes using the stentless LivaNova-Sorin Pericarbon Freedom™ valve after aortic valve replacement†. Interact Cardiovasc Thorac Surg 2018; 27:116-123. [DOI: 10.1093/icvts/ivy012] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2017] [Accepted: 01/07/2018] [Indexed: 11/12/2022] Open
Affiliation(s)
| | - Fabrizio Pirro
- Department of Cardiac Surgery, Hesperia Hospital, Modena, Italy
| | - Alina Olaru
- Department of Cardiac Surgery, Hesperia Hospital, Modena, Italy
| | | | - Clorinda Labia
- Department of Cardiac Surgery, Hesperia Hospital, Modena, Italy
| | - Luca Weltert
- Department of Cardiac Surgery, European Hospital, Rome, Italy
| |
Collapse
|
71
|
|
72
|
Anselmi A, Flecher E, Chabanne C, Ruggieri VG, Langanay T, Corbineau H, Leguerrier A, Verhoye JP. Long-term follow-up of bioprosthetic aortic valve replacement in patients aged ≤60 years. J Thorac Cardiovasc Surg 2017; 154:1534-1541.e4. [DOI: 10.1016/j.jtcvs.2017.05.103] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/12/2016] [Revised: 04/29/2017] [Accepted: 05/30/2017] [Indexed: 10/19/2022]
|
73
|
Martin E, Mohammadi S, Jacques F, Kalavrouziotis D, Voisine P, Doyle D, Perron J. Clinical Outcomes Following the Ross Procedure in Adults: A 25-Year Longitudinal Study. J Am Coll Cardiol 2017; 70:1890-1899. [PMID: 28982503 DOI: 10.1016/j.jacc.2017.08.030] [Citation(s) in RCA: 66] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/16/2017] [Revised: 08/05/2017] [Accepted: 08/14/2017] [Indexed: 10/18/2022]
Abstract
BACKGROUND Very few reports of long-term outcomes of patients who underwent the Ross procedure have been published. OBJECTIVES The authors reviewed their 25-year experience with the Ross procedure with the aim of defining very-long-term survival and factors associated with Ross-related failure. METHODS Between January 1990 and December 2014, the Ross procedure was performed in 310 adults (mean age 40.8 years) at a single institution. All patients were prospectively added to a dedicated cardiac surgery registry. Complete post-operative clinical examination and history were obtained, and transthoracic echocardiography was performed according to a standardized protocol. There was no loss to follow-up. Median follow-up was 15.1 years and up to 25 years. RESULTS Bicuspid aortic valve was diagnosed in 227 patients (73.2%), and the most common indication for surgery was aortic stenosis (n = 225 [72.6%]). Freedom from any Ross-related reintervention was 92.9% and 70.1% at 10 and 20 years, respectively. Independent risk factors for pulmonary autograft degeneration were pre-operative large aortic annulus (hazard ratio: 1.1; p = 0.01), pre-operative aortic insufficiency (hazard ratio: 2.7; p = 0.002), and concomitant replacement of the ascending aorta (hazard ratio: 7.7; p = 0.0003). There were 4 hospital deaths (1.3%), and overall survival at 10 and 20 years was 94.1% and 83.6%, respectively. Long-term survival was not significantly different in patients who required Ross-related reintervention (log-rank p = 0.70). However, compared with the general population, survival was significantly lower in patients following the Ross procedure when matched on age and sex (p < 0.0001). CONCLUSIONS The Ross procedure was associated with excellent long-term valvular outcomes and survival, regardless of the need for reintervention. Adults presenting with aortic insufficiency or a dilated aortic annulus or ascending aorta were at greater risk for reintervention. Unlike previous reports, long-term survival was lower in Ross patients compared with matched subjects.
Collapse
Affiliation(s)
- Elisabeth Martin
- Division of Cardiac Surgery, Institut Universitaire de Cardiologie et de Pneumologie de Quebec, Université Laval, Quebec City, Quebec, Canada
| | - Siamak Mohammadi
- Division of Cardiac Surgery, Institut Universitaire de Cardiologie et de Pneumologie de Quebec, Université Laval, Quebec City, Quebec, Canada
| | - Frederic Jacques
- Division of Cardiac Surgery, Institut Universitaire de Cardiologie et de Pneumologie de Quebec, Université Laval, Quebec City, Quebec, Canada
| | - Dimitri Kalavrouziotis
- Division of Cardiac Surgery, Institut Universitaire de Cardiologie et de Pneumologie de Quebec, Université Laval, Quebec City, Quebec, Canada
| | - Pierre Voisine
- Division of Cardiac Surgery, Institut Universitaire de Cardiologie et de Pneumologie de Quebec, Université Laval, Quebec City, Quebec, Canada
| | - Daniel Doyle
- Division of Cardiac Surgery, Institut Universitaire de Cardiologie et de Pneumologie de Quebec, Université Laval, Quebec City, Quebec, Canada
| | - Jean Perron
- Division of Cardiac Surgery, Institut Universitaire de Cardiologie et de Pneumologie de Quebec, Université Laval, Quebec City, Quebec, Canada.
| |
Collapse
|
74
|
„Sutureless valves“ – Dichtung und Wahrheit. ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE 2017. [DOI: 10.1007/s00398-017-0169-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
75
|
Sohmer B, Jafar R, Patel P, Chamberland MÈ, Labrosse MR, Boodhwani M. Aortic Valve Cusp Coaptation Surface Area Using 3-Dimensional Transesophageal Echocardiography Correlates with Severity of Aortic Valve Insufficiency. J Cardiothorac Vasc Anesth 2017; 32:344-351. [PMID: 29128482 DOI: 10.1053/j.jvca.2017.08.043] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2017] [Indexed: 12/14/2022]
Abstract
OBJECTIVE The aim of this study was to test both in humans and using finite element (FE) aortic valve (AV) models whether the coaptation surface area (CoapSA) correlates with aortic insufficiency (AI) severity due to dilated aortic roots to determine the validity and utility of 3-dimensional transesophageal echocardiographic-measured CoapSA. DESIGN Two-pronged, clinical and computational approach. SETTING Single university hospital. PARTICIPANTS The study comprised 10 patients with known AI and 98 FE simulations of increasingly dilated human aortic roots. INTERVENTIONS The CoapSA was calculated using intraoperative 3-dimensional transesophageal echocardiography data of patients with isolated AI and compared with established quantifiers of AI. In addition, the CoapSA and effective regurgitant orifice area (EROA) were determined using FE simulations. MEASUREMENTS AND MAIN RESULTS In the 10 AI patients, regurgitant fraction (RF) increased with EROA (R2 = 0.77, p = 0.0008); CoapSA decreased with RF (R2 = 0.72, p = 0.0020); CoapSA decreased with EROA (R2 = 0.71, p = 0.0021); and normalized CoapSA (CoapSA / [Ventriculo-Aortic Junction × Sinotubular Junction]) decreased with EROA (R2 = 0.60, p = 0.0088). In the 98 FE simulations, normalized CoapSA decreased with EROA (R2 = 0.50, p = 0.0001). CONCLUSIONS In both human and FE AV models, CoapSA was observed to be inversely correlated with AI severity, EROA, and RF, thereby supporting the validity and utility of 3D TEE-measured CoapSA. A clinical implication is the expectation that high values of CoapSA, measured intraoperatively after AV repairs, would correlate with better long-term outcomes of those repairs.
Collapse
Affiliation(s)
- Benjamin Sohmer
- Division of Cardiac Anesthesiology, University of Ottawa Heart Institute, Ottawa, Ontario, Canada.
| | - Reza Jafar
- Division of Cardiac Surgery, University of Ottawa Heart Institute, Ottawa, Ontario, Canada; Department of Mechanical Engineering, University of Ottawa, Ottawa, Ontario, Canada
| | - Prakash Patel
- Department of Anesthesiology and Critical Care, University of Pennsylvania, Philadelphia, PA
| | - Marie-Ève Chamberland
- Division of Cardiac Anesthesiology, University of Ottawa Heart Institute, Ottawa, Ontario, Canada
| | - Michel R Labrosse
- Department of Mechanical Engineering, University of Ottawa, Ottawa, Ontario, Canada
| | - Munir Boodhwani
- Division of Cardiac Surgery, University of Ottawa Heart Institute, Ottawa, Ontario, Canada
| |
Collapse
|
76
|
Rodriguez-Gabella T, Voisine P, Puri R, Pibarot P, Rodés-Cabau J. Aortic Bioprosthetic Valve Durability. J Am Coll Cardiol 2017; 70:1013-1028. [DOI: 10.1016/j.jacc.2017.07.715] [Citation(s) in RCA: 200] [Impact Index Per Article: 28.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/05/2017] [Revised: 06/25/2017] [Accepted: 07/06/2017] [Indexed: 11/25/2022]
|
77
|
Carrel T. Mid- to long-term results following aortic valve replacement using the Mitroflow xeno-pericardial bioprosthesis: somewhat different views from 2 high-volume institutions. Eur J Cardiothorac Surg 2017; 52:278-280. [PMID: 28498900 DOI: 10.1093/ejcts/ezx145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Affiliation(s)
- Thierry Carrel
- Clinic for Cardiovascular Surgery, University Hospital, University of Bern, Bern, Switzerland
| |
Collapse
|
78
|
Namdari M, Negahdari B, Eatemadi A. Paediatric nanofibrous bioprosthetic heart valve. IET Nanobiotechnol 2017; 11:493-500. [PMID: 28745279 PMCID: PMC8676244 DOI: 10.1049/iet-nbt.2016.0159] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2016] [Revised: 11/28/2016] [Accepted: 11/30/2016] [Indexed: 09/22/2023] Open
Abstract
The search for an optimal aortic valve implant with durability, calcification resistance, excellent haemodynamic parameters and ability to withstand mechanical loading is yet to be met. Thus, there has been struggled to fabricate bio-prosthetics heart valve using bioengineering. The consequential product must be resilient with suitable mechanical features, biocompatible and possess the capacity to grow. Defective heart valves replacement by surgery is now common, this improves the value and survival of life for a lot of patients. The recent paediatric heart valve implant is suboptimal due to their inability of somatic growth. They usually have multiple surgeries to change outgrown valves. Short-lived valve bio-prostheses occurring in older patients and younger ones who more usually need the replacement of its damaged heart with prosthesis led to a new invasive surgical interventions with an improved quality of life. The authors propose that nanofibre scaffold for paediatric tissue-engineered heart valve will meet most of these conditions, most particularly those related to somatic growth, and, as the nanofibre scaffold is eroded, new valve is produced, the valve matures in the child until adulthood.
Collapse
Affiliation(s)
- Mehrdad Namdari
- Department of Cardiology, Lorestan University of Medical Sciences, Khoramabad, Iran
| | - Babak Negahdari
- Department of Medical Biotechnology, School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran, Iran
| | - Ali Eatemadi
- Department of Medical Biotechnology, School of Medicine, Lorestan University of Medical Sciences, Lorestan, Iran.
| |
Collapse
|
79
|
|
80
|
Beckmann E, Martens A, Pertz J, Kaufeld T, Umminger J, Hanke JS, Schmitto JD, Cebotari S, Haverich A, Shrestha ML. Valve-sparing David I procedure in acute aortic type A dissection: a 20-year experience with more than 100 patients†. Eur J Cardiothorac Surg 2017; 52:319-324. [DOI: 10.1093/ejcts/ezx170] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/30/2016] [Accepted: 03/17/2017] [Indexed: 11/13/2022] Open
|
81
|
Guo H, Lu C, Huang H, Xie B, Liu J, Zheng S, Fan R, Chen J, Zhuang J. Long-Term Clinical Outcomes of the Carpentier-Edwards Perimount Pericardial Bioprosthesis in Chinese Patients with Single or Multiple Valve Replacement in Aortic, Mitral, or Tricuspid Positions. Cardiology 2017; 138:97-106. [PMID: 28618423 DOI: 10.1159/000471478] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/24/2017] [Accepted: 03/14/2017] [Indexed: 01/01/2023]
Abstract
OBJECTIVES To report the safety and efficacy results of a 9- to 15-year follow-up investigation among patients who had received Carpentier-Edwards Perimount (CE-P) bovine pericardial bioprostheses (Edwards Lifesciences, Irvine, CA, USA) for valve replacement. METHODS This retrospective study investigated freedom from structural valve deterioration (SVD) as well as survival and reoperation among different age and etiology groups in patients who were implanted with a CE-P bioprosthesis at Guangdong General Hospital between 2001 and 2007. Kaplan-Meier survival analysis and multivariate Cox proportional hazards regression were performed. RESULTS The mean age of the patients (N = 225) was only 61.2 ± 11.5 years at valve replacement. More than half of the patients (55.1%) had rheumatic heart disease. The survival rates were 86.46, 81.58, and 74.42% at 5 years, 64.39, 66.19, and 55.85% at 10 years, and 48.37, 57.33, and 46.54% at 15 years for the groups with mitral valve replacement (MVR), aortic valve replacement (AVR), and double valve replacement (DVR), respectively. The median time to freedom from SVD was 12.5, 13.2, and 11.2 years, respectively, for patients with MVR, AVR, and DVR. A higher age at valve replacement was a significant risk factor for SVD in all patients (p < 0.01). CONCLUSIONS Good long-term clinical results of CE-P valves have been demonstrated in Chinese patients >60 years.
Collapse
Affiliation(s)
- Huiming Guo
- Department of Cardiac Surgery, Guangdong Provincial Cardiovascular Institute, Guangdong General Hospital, Guangzhou, China
| | | | | | | | | | | | | | | | | |
Collapse
|
82
|
Puskas JD, Bavaria JE, Svensson LG, Blackstone EH, Griffith B, Gammie JS, Heimansohn DA, Sadowski J, Bartus K, Johnston DR, Rozanski J, Rosengart T, Girardi LN, Klodell CT, Mumtaz MA, Takayama H, Halkos M, Starnes V, Boateng P, Timek TA, Ryan W, Omer S, Smith CR. The COMMENCE trial: 2-year outcomes with an aortic bioprosthesis with RESILIA tissue†. Eur J Cardiothorac Surg 2017; 52:432-439. [DOI: 10.1093/ejcts/ezx158] [Citation(s) in RCA: 53] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2016] [Accepted: 04/14/2017] [Indexed: 12/11/2022] Open
Affiliation(s)
- John D. Puskas
- Department of Cardiovascular Surgery, Mount Sinai Saint Luke’s, New York, NY, USA
| | - Joseph E. Bavaria
- Department of Cardiovascular Surgery, Hospital of the University of Pennsylvania, Philadelphia, PA, USA
| | - Lars G. Svensson
- Heart and Vascular Institute, Cleveland Clinic Foundation, Cleveland, OH, USA
| | - Eugene H. Blackstone
- Department of Thoracic and Cardiovascular Surgery, Cleveland Clinic Foundation, Cleveland, OH, USA
| | - Bartley Griffith
- Department of Thoracic and Cardiovascular Surgery, University of Maryland, Baltimore, MD, USA
| | - James S. Gammie
- Department of Surgery, University of Maryland Medical Center, Baltimore, MD, USA
| | - David A. Heimansohn
- Department of Cardiothoracic Surgery, St Vincent Heart Center, Indianapolis, IN, USA
| | - Jerzy Sadowski
- Department of Cardiovascular Surgery and Transplantology, Jagiellonian University, John Paul II Hospital, Krakow, Poland
| | - Krzysztof Bartus
- Department of Cardiovascular Surgery and Transplantology, Jagiellonian University, John Paul II Hospital, Krakow, Poland
| | - Douglas R. Johnston
- Department of Thoracic and Cardiovascular Surgery, Cleveland Clinic Foundation, Cleveland, OH, USA
| | | | - Todd Rosengart
- Michael E DeBakey Department of Surgery, Baylor College of Medicine, Houston, TX, USA
| | - Leonard N. Girardi
- Department of Cardiothoracic Surgery, New York Presbyterian Hospital, New York, NY, USA
| | | | - Mubashir A. Mumtaz
- Department of Cardiovascular and Thoracic Surgery, Pinnacle Health, Harrisburg, PA, USA
| | - Hiroo Takayama
- Division of Cardiothoracic and Vascular Surgery, Department of Surgery, Columbia University-New York Presbyterian Hospital, New York, NY, USA
| | - Michael Halkos
- Division of Cardiothoracic Surgery, Emory University School of Medicine, Atlanta, GA, USA
| | - Vaughn Starnes
- Department of Surgery, University of Southern California, Los Angeles, CA, USA
| | - Percy Boateng
- Department of Cardiovascular Surgery, Mount Sinai Medical Center, New York, NY, USA
| | - Tomasz A. Timek
- Division of Cardiothoracic Surgery, Spectrum Health Medical Group, Grand Rapids, MI, USA
| | - William Ryan
- Department of Cardiovascular Surgery, Heart Hospital Baylor, Plano, TX, USA
| | - Shuab Omer
- Department of Cardiovascular Surgery, Michael E DeBakey VA Medical Center, Houston, TX, USA
| | - Craig R. Smith
- Department of Surgery, Columbia Presbyterian Medical Center, New York, NY, USA
| | | |
Collapse
|
83
|
Ouzounian M, Mazine A, David TE. The Ross procedure is the best operation to treat aortic stenosis in young and middle-aged adults. J Thorac Cardiovasc Surg 2017. [PMID: 28625775 DOI: 10.1016/j.jtcvs.2017.03.156] [Citation(s) in RCA: 47] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Affiliation(s)
- Maral Ouzounian
- Peter Munk Cardiac Centre, Division of Cardiac Surgery, Department of Surgery, University of Toronto, Toronto, Ontario, Canada.
| | - Amine Mazine
- Peter Munk Cardiac Centre, Division of Cardiac Surgery, Department of Surgery, University of Toronto, Toronto, Ontario, Canada
| | - Tirone E David
- Peter Munk Cardiac Centre, Division of Cardiac Surgery, Department of Surgery, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
84
|
Korteland NM, Etnel JRG, Arabkhani B, Mokhles MM, Mohamad A, Roos-Hesselink JW, Bogers AJJC, Takkenberg JJM. Mechanical aortic valve replacement in non-elderly adults: meta-analysis and microsimulation. Eur Heart J 2017; 38:3370-3377. [DOI: 10.1093/eurheartj/ehx199] [Citation(s) in RCA: 69] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2016] [Accepted: 03/28/2017] [Indexed: 11/12/2022] Open
|
85
|
Díaz R, Hernández-Vaquero D, Silva J, Pascual I, de la Hera JM, León V, Martín M, Barriales V, Colunga S, Del Valle R, Morís C. Real Structural Valve Deterioration of the Mitroflow Aortic Prosthesis: Competing Risk Analysis. ACTA ACUST UNITED AC 2017; 70:1074-1081. [PMID: 28465144 DOI: 10.1016/j.rec.2017.02.041] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2016] [Accepted: 02/16/2017] [Indexed: 11/24/2022]
Abstract
INTRODUCTION AND OBJECTIVES The Mitroflow aortic prosthesis is a bovine pericardial bioprosthesis specially designed to increase the valve area in relation to its size. There is controversy regarding the pattern of structural valve deterioration (SVD). Our aim was to determine the cumulative incidence of SVD, risk factors influencing its occurrence, and its impact on mortality. METHODS A total of 1028 patients were clinically and echocardiographically followed up. Because the study population was elderly and had heart disease, we used a competing risk analysis. RESULTS The percentage of patients with SVD at 5 years was 4.22% (95%CI, 2.96-5.81) and was 15.77% at 8 years (95%CI, 12.46-19.43). The incidence was higher for small valves (19mm and 21mm) reaching 6.43% at 5 years (95%CI, 4.48-8.84) and 20.06% at 8 years (95%CI, 15.53-25.01). Severe patient-prosthesis mismatch (PPM) influenced the incidence of SVD (sHR, 3.53; 95%CI, 2.20-5.66; P < .001) but moderate PPM had no impact. The most powerful predictor of mortality was the presence of SVD (HR, 4.59; 95%CI, 2.91-7.22; P < .001). CONCLUSIONS This study used a definition based on the increase in the transprosthetic gradient and found a higher incidence of SVD of the Mitroflow prosthesis than that reported by other series, especially for sizes 19mm and 21mm and in patients with severe PPM. The incidence of SVD increased exponentially from the fifth year after implantation and its occurrence led to a 4.5-fold increase in the risk of death.
Collapse
Affiliation(s)
- Rocío Díaz
- Área del Corazón, Hospital Universitario Central de Asturias, Oviedo, Asturias, Spain.
| | | | - Jacobo Silva
- Área del Corazón, Hospital Universitario Central de Asturias, Oviedo, Asturias, Spain; Departamento de Medicina, Universidad de Oviedo, Oviedo, Asturias, Spain
| | - Isaac Pascual
- Área del Corazón, Hospital Universitario Central de Asturias, Oviedo, Asturias, Spain
| | - Jesús M de la Hera
- Área del Corazón, Hospital Universitario Central de Asturias, Oviedo, Asturias, Spain
| | - Víctor León
- Área del Corazón, Hospital Universitario Central de Asturias, Oviedo, Asturias, Spain
| | - María Martín
- Área del Corazón, Hospital Universitario Central de Asturias, Oviedo, Asturias, Spain
| | - Vicente Barriales
- Área del Corazón, Hospital Universitario Central de Asturias, Oviedo, Asturias, Spain
| | - Santiago Colunga
- Área del Corazón, Hospital Universitario Central de Asturias, Oviedo, Asturias, Spain
| | - Raquel Del Valle
- Área del Corazón, Hospital Universitario Central de Asturias, Oviedo, Asturias, Spain
| | - César Morís
- Área del Corazón, Hospital Universitario Central de Asturias, Oviedo, Asturias, Spain; Departamento de Medicina, Universidad de Oviedo, Oviedo, Asturias, Spain
| |
Collapse
|
86
|
Theron A, Ravis E, Grisoli D, Jaussaud N, Morera P, Candolfi P, Boleckova J, Lagier D, Amanatiou C, Messous L, Gariboldi V, Collart F. Rapid-deployment aortic valve replacement for severe aortic stenosis: 1-year outcomes in 150 patients†. Interact Cardiovasc Thorac Surg 2017; 25:68-74. [DOI: 10.1093/icvts/ivx050] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2016] [Accepted: 02/01/2017] [Indexed: 11/13/2022] Open
|
87
|
Nishimura RA, Otto CM, Bonow RO, Carabello BA, Erwin JP, Fleisher LA, Jneid H, Mack MJ, McLeod CJ, O'Gara PT, Rigolin VH, Sundt TM, Thompson A. 2017 AHA/ACC Focused Update of the 2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines. Circulation 2017; 135:e1159-e1195. [PMID: 28298458 DOI: 10.1161/cir.0000000000000503] [Citation(s) in RCA: 1421] [Impact Index Per Article: 203.0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
| | | | - Robert O Bonow
- Focused Update writing group members are required to recuse themselves from voting on sections to which their specific relationships with industry may apply; see Appendix 1 for detailed information. ACC/AHA Representative. ACC/AHA Task Force on Clinical Practice Guidelines Liaison. SCAI Representative. STS Representative. ASE Representative. AATS Representative. SCA Representative
| | - Blase A Carabello
- Focused Update writing group members are required to recuse themselves from voting on sections to which their specific relationships with industry may apply; see Appendix 1 for detailed information. ACC/AHA Representative. ACC/AHA Task Force on Clinical Practice Guidelines Liaison. SCAI Representative. STS Representative. ASE Representative. AATS Representative. SCA Representative
| | - John P Erwin
- Focused Update writing group members are required to recuse themselves from voting on sections to which their specific relationships with industry may apply; see Appendix 1 for detailed information. ACC/AHA Representative. ACC/AHA Task Force on Clinical Practice Guidelines Liaison. SCAI Representative. STS Representative. ASE Representative. AATS Representative. SCA Representative
| | - Lee A Fleisher
- Focused Update writing group members are required to recuse themselves from voting on sections to which their specific relationships with industry may apply; see Appendix 1 for detailed information. ACC/AHA Representative. ACC/AHA Task Force on Clinical Practice Guidelines Liaison. SCAI Representative. STS Representative. ASE Representative. AATS Representative. SCA Representative
| | - Hani Jneid
- Focused Update writing group members are required to recuse themselves from voting on sections to which their specific relationships with industry may apply; see Appendix 1 for detailed information. ACC/AHA Representative. ACC/AHA Task Force on Clinical Practice Guidelines Liaison. SCAI Representative. STS Representative. ASE Representative. AATS Representative. SCA Representative
| | - Michael J Mack
- Focused Update writing group members are required to recuse themselves from voting on sections to which their specific relationships with industry may apply; see Appendix 1 for detailed information. ACC/AHA Representative. ACC/AHA Task Force on Clinical Practice Guidelines Liaison. SCAI Representative. STS Representative. ASE Representative. AATS Representative. SCA Representative
| | - Christopher J McLeod
- Focused Update writing group members are required to recuse themselves from voting on sections to which their specific relationships with industry may apply; see Appendix 1 for detailed information. ACC/AHA Representative. ACC/AHA Task Force on Clinical Practice Guidelines Liaison. SCAI Representative. STS Representative. ASE Representative. AATS Representative. SCA Representative
| | - Patrick T O'Gara
- Focused Update writing group members are required to recuse themselves from voting on sections to which their specific relationships with industry may apply; see Appendix 1 for detailed information. ACC/AHA Representative. ACC/AHA Task Force on Clinical Practice Guidelines Liaison. SCAI Representative. STS Representative. ASE Representative. AATS Representative. SCA Representative
| | - Vera H Rigolin
- Focused Update writing group members are required to recuse themselves from voting on sections to which their specific relationships with industry may apply; see Appendix 1 for detailed information. ACC/AHA Representative. ACC/AHA Task Force on Clinical Practice Guidelines Liaison. SCAI Representative. STS Representative. ASE Representative. AATS Representative. SCA Representative
| | - Thoralf M Sundt
- Focused Update writing group members are required to recuse themselves from voting on sections to which their specific relationships with industry may apply; see Appendix 1 for detailed information. ACC/AHA Representative. ACC/AHA Task Force on Clinical Practice Guidelines Liaison. SCAI Representative. STS Representative. ASE Representative. AATS Representative. SCA Representative
| | - Annemarie Thompson
- Focused Update writing group members are required to recuse themselves from voting on sections to which their specific relationships with industry may apply; see Appendix 1 for detailed information. ACC/AHA Representative. ACC/AHA Task Force on Clinical Practice Guidelines Liaison. SCAI Representative. STS Representative. ASE Representative. AATS Representative. SCA Representative
| |
Collapse
|
88
|
Nishimura RA, Otto CM, Bonow RO, Carabello BA, Erwin JP, Fleisher LA, Jneid H, Mack MJ, McLeod CJ, O'Gara PT, Rigolin VH, Sundt TM, Thompson A. 2017 AHA/ACC Focused Update of the 2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines. J Am Coll Cardiol 2017; 70:252-289. [PMID: 28315732 DOI: 10.1016/j.jacc.2017.03.011] [Citation(s) in RCA: 1841] [Impact Index Per Article: 263.0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
89
|
Zayat R, Arias-Pinilla J, Aljalloud A, Musetti G, Goetzenich A, Autschbach R, van Gemmeren T, Niedeggen A, Hatam N. Performance of the Labcor Dokimos Plus pericardial aortic prosthesis: a single-centre experience. Interact Cardiovasc Thorac Surg 2017; 24:355-362. [PMID: 28025312 DOI: 10.1093/icvts/ivw401] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2016] [Accepted: 11/07/2016] [Indexed: 11/14/2022] Open
Abstract
Objectives In patients with a small aortic annulus, aortic valve replacement (AVR) is frequently associated with high residual pressure gradients. Supra-annular pericardial aortic prostheses are gaining popularity due to the increased effective orifice areas (EOA) and resulting lower gradients. This study reports the clinical and echocardiographic results following implantation of the new supra-annular pericardial aortic prosthesis Dokimos Plus (Labcor, Belo Horizonte, Brazil). Methods Between October 2013 and July 2015, 137 patients (41% women, mean age: 74 years) underwent supra-annular AVR with or without concomitant procedures using the Dokimos Plus prosthesis in our department. Transthoracic echocardiography was performed pre- and postoperatively on all patients to assess haemodynamic parameters (gradients, acceleration time [AT], Doppler velocity indices [DVIs] and indexed EOA [EOAI]) and to detect paravalvular leakage (PVL). Data were collected retrospectively from our hospital databases. Methods Patients were grouped by prosthesis size: Most patients received 23-mm (57.6%), followed by 21-mm (19%), 25-mm (15.4%) and 27-mm (8%) prostheses. The mean EOAI in all groups was 1.1 ± 0.26 cm 2 /m 2 . Pressure gradients were low in all groups (mean: 8.9 ± 4.4 mmHg; peak: 18.8 ± 6.8 mmHg); AT and DVI were in the normal range according to American Society of Echocardiography/European Association of Cardiovascular Imaging recommendations (mean AT 73.3 ± 29 ms; mean DVI 0.5 ± 0.2). One patient had severe PVL and one presented with central regurgitation, both requiring re-intervention. The mortality rate was 5.1% ( n = 7); none of the cases was associated with valve insufficiency. Conclusions The Dokimos prosthesis showed a satisfactory overall performance, presenting low gradients and DVIs as well as high EOAI. Further investigations are needed to analyse the cases of regurgitation and monitor long-term performance.
Collapse
Affiliation(s)
- Rashad Zayat
- Department of Thoracic and Cardiovascular Surgery, RWTH University Hospital, Aachen, Germany
| | - Jessica Arias-Pinilla
- Department of Thoracic and Cardiovascular Surgery, RWTH University Hospital, Aachen, Germany
| | - Ali Aljalloud
- Department of Thoracic and Cardiovascular Surgery, RWTH University Hospital, Aachen, Germany
| | - Giulia Musetti
- Department of Thoracic and Cardiovascular Surgery, RWTH University Hospital, Aachen, Germany
| | - Andreas Goetzenich
- Department of Thoracic and Cardiovascular Surgery, RWTH University Hospital, Aachen, Germany
| | - Rüdiger Autschbach
- Department of Thoracic and Cardiovascular Surgery, RWTH University Hospital, Aachen, Germany
| | | | | | - Nima Hatam
- Department of Thoracic and Cardiovascular Surgery, RWTH University Hospital, Aachen, Germany
| |
Collapse
|
90
|
|
91
|
Konventioneller Aortenklappenersatz. ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE 2016. [DOI: 10.1007/s00398-016-0095-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
92
|
Padala M. Biomaterials for heart valve replacement: Conjectures and refutations. J Thorac Cardiovasc Surg 2016; 152:1175-6. [PMID: 27349286 DOI: 10.1016/j.jtcvs.2016.05.055] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/26/2016] [Accepted: 05/27/2016] [Indexed: 10/21/2022]
Affiliation(s)
- Muralidhar Padala
- Structural Heart Research & Innovation Lab, Division of Cardiothoracic Surgery, Carlyle Fraser Heart Center, Emory University, Atlanta, Ga.
| |
Collapse
|
93
|
Raghav V, Okafor I, Quach M, Dang L, Marquez S, Yoganathan AP. Long-Term Durability of Carpentier-Edwards Magna Ease Valve: A One Billion Cycle In Vitro Study. Ann Thorac Surg 2016; 101:1759-65. [PMID: 26806168 DOI: 10.1016/j.athoracsur.2015.10.069] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2015] [Revised: 08/24/2015] [Accepted: 10/26/2015] [Indexed: 11/28/2022]
Abstract
BACKGROUND Durability and hemodynamic performance are top considerations in selecting a valve for valve replacement surgery. This study was conducted in order to evaluate the long-term mechanical durability and hydrodynamic performance of the Carpentier-Edwards PERIMOUNT Magna Ease Bioprostheses, through 1 billion cycles (equivalent to 25 years). METHODS In vitro valve hydrodynamic performance, durability, and quantitative flow visualization were conducted in accordance with ISO 5840:2005 heart valve standard. The study valves were subjected to accelerated valve cycling to an equivalent of 25 years of wear. Hydrodynamic evaluations at intervals of 100 million cycles (2.5 years) were performed on the study valves. New uncycled Magna Ease valves were used as hydrodynamic controls in this study. A quantitative assessment of the fluid motion downstream of the control and study valves was performed using particle image velocimetry. The results between the test and control valves were compared to assess valve performance after an equivalent of 25 years of wear. RESULTS All study valves met the ISO 5840 requirements for effective orifice area, 1.81 ± 0.06 cm(2) and 2.06 ± 0.17 cm(2), and regurgitant fraction, 1.11% ± 0.87% and 2.5% ± 2.34%, for the 21 mm and 23 mm study valves, respectively. The flow characterization of the control valves and the billion-cycle valves demonstrated that the valves exhibited similar flow characteristics. The velocity and shear stress fields were similar between the control and study valves. CONCLUSIONS The Magna Ease valves demonstrated excellent durability and hydrodynamic performance after an equivalent of 25 years of simulated in vitro wear. All study valves successfully endured 1 billion cycles of simulated wear, 5 times longer than the standard requirement for a tissue valve as stipulated in ISO 5840.
Collapse
Affiliation(s)
- Vrishank Raghav
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology & Emory University, Atlanta
| | - Ikechukwu Okafor
- School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, Georgia
| | | | - Lynn Dang
- Edwards Lifesciences, Irvine, California
| | | | - Ajit P Yoganathan
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology & Emory University, Atlanta; School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, Georgia.
| |
Collapse
|
94
|
Shih T. Invited Commentary. Ann Thorac Surg 2015; 100:859. [PMID: 26354622 DOI: 10.1016/j.athoracsur.2015.03.067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/24/2015] [Revised: 03/24/2015] [Accepted: 03/25/2015] [Indexed: 11/27/2022]
Affiliation(s)
- Terry Shih
- Department of Surgery, University of Michigan, 1500 E Medical Center Dr, Ann Arbor, MI48105.
| |
Collapse
|