51
|
Ji D, Liu L, Li S, Chen C, Lu Y, Wu J, Liu Q. Smartphone-based cyclic voltammetry system with graphene modified screen printed electrodes for glucose detection. Biosens Bioelectron 2017; 98:449-456. [DOI: 10.1016/j.bios.2017.07.027] [Citation(s) in RCA: 71] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2017] [Revised: 07/07/2017] [Accepted: 07/10/2017] [Indexed: 12/24/2022]
|
52
|
Wang G, Xu Q, Liu L, Su X, Lin J, Xu G, Luo X. Mixed Self-Assembly of Polyethylene Glycol and Aptamer on Polydopamine Surface for Highly Sensitive and Low-Fouling Detection of Adenosine Triphosphate in Complex Media. ACS APPLIED MATERIALS & INTERFACES 2017; 9:31153-31160. [PMID: 28831806 DOI: 10.1021/acsami.7b09529] [Citation(s) in RCA: 52] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Detection of disease biomarkers within complex biological media is a substantial outstanding challenge because of severe biofouling and nonspecific adsorptions. Herein, a reliable strategy for sensitive and low-fouling detection of a biomarker, adenosine triphosphate (ATP) in biological samples was developed through the formation of a mixed self-assembled sensing interface, which was constructed by simultaneously self-assembling polyethylene glycol (PEG) and ATP aptamer onto the self-polymerized polydopamine-modified electrode surface. The developed aptasensor exhibited high selectivity and sensitivity toward the detection of ATP, and the linear range was 0.1-1000 pM, with a detection limit down to 0.1 pM. Moreover, owing to the presence of PEG within the sensing interface, the aptasensor was capable of sensing ATP in complex biological media such as human plasma with significantly reduced nonspecific adsorption effect. Assaying ATP in real biological samples including breast cancer cell lysates further proved the feasibility of this biosensor for practical application.
Collapse
Affiliation(s)
- Guixiang Wang
- Key Laboratory of Sensor Analysis of Tumor Marker, Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology , Qingdao 266042, China
- College of Chemistry and Chemical Engineering, Taishan University , Taian 271021, China
| | - Qingjun Xu
- Key Laboratory of Sensor Analysis of Tumor Marker, Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology , Qingdao 266042, China
| | - Lei Liu
- Key Laboratory of Sensor Analysis of Tumor Marker, Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology , Qingdao 266042, China
| | - Xiaoli Su
- Key Laboratory of Sensor Analysis of Tumor Marker, Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology , Qingdao 266042, China
| | - Jiehua Lin
- Key Laboratory of Sensor Analysis of Tumor Marker, Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology , Qingdao 266042, China
| | - Guiyun Xu
- Key Laboratory of Sensor Analysis of Tumor Marker, Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology , Qingdao 266042, China
| | - Xiliang Luo
- Key Laboratory of Sensor Analysis of Tumor Marker, Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology , Qingdao 266042, China
| |
Collapse
|
53
|
Qiu Z, Shu J, Tang D. Bioresponsive Release System for Visual Fluorescence Detection of Carcinoembryonic Antigen from Mesoporous Silica Nanocontainers Mediated Optical Color on Quantum Dot-Enzyme-Impregnated Paper. Anal Chem 2017; 89:5152-5160. [PMID: 28376620 DOI: 10.1021/acs.analchem.7b00989] [Citation(s) in RCA: 320] [Impact Index Per Article: 45.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
An all-in-one paper-based analytical device (PAD) was successfully developed for visual fluorescence detection of carcinoembryonic antigen (CEA) on CdTe/CdSe quantum dot (QD)-enzyme-impregnated paper by coupling with a bioresponsive controlled-release system from DNA-gated mesoporous silica nanocontainers (MSNs). The assay was carried out in a centrifuge tube by using glucose-loaded MSNs with a CEA aptamer and a QD-enzyme-paper attached on the lid. Initially, single-strand complementary DNA to a CEA aptamer was covalently conjugated to the aminated MSN, and then glucose (enzyme substrate) molecules were gated into the pore with the help of the aptamer. Glucose oxidase (GOD) and CdTe/CdSe QDs were coimmobilized on paper for the visual fluorescence signal output. Upon target CEA introduction in the detection cell, the analyte specifically reacted with the immobilized aptamer on the MSN to open the pore, thereby resulting in the glucose release. The released glucose was oxidized by the immobilized GOD on paper to produce gluconic acid and hydrogen peroxide, and the latter quenched the fluorescence of CdTe/CdSe QDs, which could be determined by the naked eye on a portable smartphone and a commercial fluorospectrometer. Under optimal conditions, the PAD-based sensing system enabled sensitive discrimination of target CEA against other biomarkers or proteins in a linear range of 0.05-20 ng mL-1 with a limit of detection of 6.7 pg mL-1 (ppt). In addition, our strategy displayed high specificity, good reproducibility, and acceptable accuracy for analyzing human serum specimens with a commercial human CEA ELISA kit. Importantly, this methodology offers promise for simple analysis of biological samples and is suitable for use in the mass production of miniaturized devices, thus opening new opportunities for protein diagnostics and biosecurity.
Collapse
Affiliation(s)
- Zhenli Qiu
- Key Laboratory of Analysis and Detection for Food Safety (MOE & Fujian Province), Collaborative Innovation Center of Detection Technology for Haixi Food Safety and Products (Fujian Province), State Key Laboratory of Photocatalysis on Energy and Environment, Department of Chemistry, Fuzhou University , Fuzhou 350108, People's Republic of China
| | - Jian Shu
- Key Laboratory of Analysis and Detection for Food Safety (MOE & Fujian Province), Collaborative Innovation Center of Detection Technology for Haixi Food Safety and Products (Fujian Province), State Key Laboratory of Photocatalysis on Energy and Environment, Department of Chemistry, Fuzhou University , Fuzhou 350108, People's Republic of China
| | - Dianping Tang
- Key Laboratory of Analysis and Detection for Food Safety (MOE & Fujian Province), Collaborative Innovation Center of Detection Technology for Haixi Food Safety and Products (Fujian Province), State Key Laboratory of Photocatalysis on Energy and Environment, Department of Chemistry, Fuzhou University , Fuzhou 350108, People's Republic of China
| |
Collapse
|
54
|
Roda A, Calabretta MM, Calabria D, Caliceti C, Cevenini L, Lopreside A, Zangheri M. Smartphone-Based Biosensors for Bioanalytics. PAST, PRESENT AND FUTURE CHALLENGES OF BIOSENSORS AND BIOANALYTICAL TOOLS IN ANALYTICAL CHEMISTRY: A TRIBUTE TO PROFESSOR MARCO MASCINI 2017. [DOI: 10.1016/bs.coac.2017.05.007] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|