51
|
Identification and characterization of monoclonal antibody fragments cleaved at the complementarity determining region using orthogonal analytical methods. J Chromatogr B Analyt Technol Biomed Life Sci 2017; 1048:121-129. [DOI: 10.1016/j.jchromb.2017.02.019] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2016] [Revised: 02/14/2017] [Accepted: 02/18/2017] [Indexed: 11/20/2022]
|
52
|
Nowak PM, Woźniakiewicz M, Michalik M, Fiedor L, Kościelniak P. Capillary coating as an important factor in optimization of the off-line and on-line MEKC assays of the highly hydrophobic enzyme chlorophyllase. Anal Bioanal Chem 2017; 409:1493-1501. [PMID: 27888314 PMCID: PMC5306352 DOI: 10.1007/s00216-016-0097-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2016] [Revised: 11/07/2016] [Accepted: 11/11/2016] [Indexed: 12/15/2022]
Abstract
The choice between bare and coated capillaries is a key decision in the development and use of any methods based on capillary electrophoresis. In this work several permanently and dynamically coated capillaries were successfully implemented in a previously developed micellar electrokinetic chromatography (MEKC) assay of the plant membrane enzyme chlorophyllase. The results obtained demonstrate the rationale behind the use of capillary coating, which is crucial for successful optimization of both the off-line mode and the on-line/electrophoretically mediated microanalysis assay mode. The application of an amine permanently coated capillary (eCAP) is a simple way to significantly increase the repeatability of migration times and peak areas, and to ensure a strong electroosmotic flow that considerably decreases the overall analysis time. A dynamic coating (CEofix) allows one to apply an on-line incubation to control the reaction progress inside the capillary, and to increase the signal-to-noise ratio and peak efficiency. The dynamic coating is possible with use of both the normally applied uncoated silica capillary and the precoated amine capillary, which ensures more repeatable migration times. The strong points of the uncoated silica capillary are its attractive price and wide range of pH that can be applied. The characteristics presented may simplify the choice of capillary modification, especially in the case of hydrophobic analytes, MEKC-based separations, and other enzymatic assays.
Collapse
Affiliation(s)
- Paweł Mateusz Nowak
- Faculty of Chemistry, Jagiellonian University in Kraków, Ingardena 3, 30-060, Kraków, Poland.
| | - Michał Woźniakiewicz
- Faculty of Chemistry, Jagiellonian University in Kraków, Ingardena 3, 30-060, Kraków, Poland
| | - Maciej Michalik
- Faculty of Biochemistry, Biophysics and Biotechnology, Jagiellonian University in Kraków, Gronostajowa 7, 30-387, Kraków, Poland
| | - Leszek Fiedor
- Faculty of Biochemistry, Biophysics and Biotechnology, Jagiellonian University in Kraków, Gronostajowa 7, 30-387, Kraków, Poland
| | - Paweł Kościelniak
- Faculty of Chemistry, Jagiellonian University in Kraków, Ingardena 3, 30-060, Kraków, Poland
| |
Collapse
|
53
|
Poulsen NN, Østergaard J, Petersen NJ, Daasbjerg K, Iruthayaraj J, Dedinaite A, Makuska R, Jensen H. Automated coating procedures to produce poly(ethylene glycol) brushes in fused-silica capillaries. J Sep Sci 2016; 40:779-788. [DOI: 10.1002/jssc.201600878] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2016] [Revised: 11/05/2016] [Accepted: 11/09/2016] [Indexed: 11/08/2022]
Affiliation(s)
| | - Jesper Østergaard
- Department of Pharmacy; University of Copenhagen; Copenhagen Denmark
| | | | - Kim Daasbjerg
- Department of Chemistry; Aarhus University; Aarhus Denmark
- Interdisciplinary Nanoscience Center (iNANO); Aarhus University; Aarhus Denmark
- Carbon Dioxide Activation Center; Aarhus University; Aarhus Denmark
| | - Joseph Iruthayaraj
- Interdisciplinary Nanoscience Center (iNANO); Aarhus University; Aarhus Denmark
- Biological and Chemical Engineering Division; Aarhus University; Aarhus N Denmark
| | - Andra Dedinaite
- Department of Chemistry; Surface and Corrosion Science; School of Chemical Sciences and Engineering; KTH Royal Institute of Technology; Stockholm Sweden
| | - Ricardas Makuska
- Department of Polymer Chemistry; Vilnius University; Vilnius Lithuania
| | - Henrik Jensen
- Department of Pharmacy; University of Copenhagen; Copenhagen Denmark
| |
Collapse
|
54
|
Performance and selectivity of cationic nanoparticle pseudo‐stationary phases in electrokinetic chromatography. Electrophoresis 2016; 38:730-737. [DOI: 10.1002/elps.201600380] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2016] [Revised: 10/21/2016] [Accepted: 11/13/2016] [Indexed: 11/07/2022]
|
55
|
Vitali L, Gonçalves S, Rodrigues V, Fávere VT, Micke GA. Development of a fast method for simultaneous determination of hippuric acid, mandelic acid, and creatinine in urine by capillary zone electrophoresis using polymer multilayer-coated capillary. Anal Bioanal Chem 2016; 409:1943-1950. [DOI: 10.1007/s00216-016-0142-4] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2016] [Revised: 11/28/2016] [Accepted: 12/09/2016] [Indexed: 10/20/2022]
|
56
|
Zhang C, Hage DS. Glycoform analysis of alpha 1-acid glycoprotein by capillary electrophoresis. J Chromatogr A 2016; 1475:102-109. [PMID: 27863712 PMCID: PMC5147584 DOI: 10.1016/j.chroma.2016.11.014] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2016] [Revised: 11/09/2016] [Accepted: 11/10/2016] [Indexed: 11/25/2022]
Abstract
A relatively fast and reproducible CE separation was developed for the glycoform analysis of α1-acid glycoprotein (AGP). Factors that were considered included the pH for this separation and various techniques for coating the capillary and/or to minimize electroosmotic flow and protein adsorption. Optimum resolution of the AGP glycoforms was obtained at pH 4.2 with a running buffer containing 0.1% Brij 35 and by using static and dynamic coatings of PEO on the capillary. These conditions made it possible to separate nine AGP glycoform bands in about 20min. The limit of detection (based on absorbance measurements) ranged from 0.09 to 0.38μM for these AGP glycoform bands, and the linear range extended up to a total AGP concentration of at least 240μM. The migration times for the glycoform bands had typical within-day and day-to-day precisions of ±0.16-0.23% or less, respectively, on a single treated capillary and the variation between capillaries was ±0.56% or less. A charge ladder approach was employed to examine the mass or charge differences in the glycoforms that made up these bands, giving a good fit to a model in which the neighboring bands differed by one charge (e.g., from a sialic acid residue) and had an average mass difference of approximately 0.7-0.9kDa. The approaches used to develop this separation method are not limited to AGP but could be extended to the analysis of other glycoproteins by CE.
Collapse
Affiliation(s)
- Chenhua Zhang
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | - David S Hage
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA.
| |
Collapse
|
57
|
Zhang Y, Wang W, Ma X, Jia L. Polydopamine assisted fabrication of titanium oxide nanoparticles modified column for proteins separation by capillary electrochromatography. Anal Biochem 2016; 512:103-109. [DOI: 10.1016/j.ab.2016.08.015] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2016] [Revised: 08/12/2016] [Accepted: 08/18/2016] [Indexed: 01/04/2023]
|
58
|
Bodnar J, Hajba L, Guttman A. A fully automated linear polyacrylamide coating and regeneration method for capillary electrophoresis of proteins. Electrophoresis 2016; 37:3154-3159. [PMID: 27731499 DOI: 10.1002/elps.201600405] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2016] [Revised: 09/09/2016] [Accepted: 09/10/2016] [Indexed: 11/07/2022]
Abstract
Surface modification of the inner capillary wall in CE of proteins is frequently required to alter EOF and to prevent protein adsorption. Manual protocols for such coating techniques are cumbersome. In this paper, an automated covalent linear polyacrylamide coating and regeneration process is described to support long-term stability of fused-silica capillaries for protein analysis. The stability of the resulting capillary coatings was evaluated by a large number of separations using a three-protein test mixture in pH 6 and 3 buffer systems. The results were compared to that obtained with the use of bare fused-silica capillaries. If necessary, the fully automated capillary coating process was easily applied to regenerate the capillary to extend its useful life-time.
Collapse
Affiliation(s)
- Judit Bodnar
- MTA-PE Translational Glycomics Research Group, University of Pannonia, Veszprem, Hungary
| | - Laszlo Hajba
- MTA-PE Translational Glycomics Research Group, University of Pannonia, Veszprem, Hungary
| | - Andras Guttman
- MTA-PE Translational Glycomics Research Group, University of Pannonia, Veszprem, Hungary.,Horváth Csaba Memorial Institute for Bioanalytical Research, University of Debrecen, Debrecen, Hungary
| |
Collapse
|
59
|
Tarongoy FM, Haddad PR, Boysen RI, Hearn MTW, Quirino JP. Open tubular-capillary electrochromatography: Developments and applications from 2013 to 2015. Electrophoresis 2016; 37:66-85. [PMID: 26497640 DOI: 10.1002/elps.201500339] [Citation(s) in RCA: 50] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2015] [Revised: 09/24/2015] [Accepted: 09/24/2015] [Indexed: 02/06/2023]
Abstract
Open tubular CEC (OT-CEC) separates analyte mixtures by a combination of electrophoretic, electro-osmotic, and/or chromatographic effects. OT-CEC research is an active and growing field, with studies encompassing a wide range of investigations related to new strategies for chemical modification of the inner surface of the capillary, leading to the introduction of novel stationary phase coatings. This review has examined the literature on OT-CEC from 2013 to August 2015 and highlights the developments in the fabrication of highly selective stationary phases, based on materials that include cyclodextrin chiral selectors, graphene and graphene oxide, metal-organic frameworks, molecularly imprinted polymers, nanoparticles, nanolatex particles, nanocomposites, in situ generated polymers, block polymers, tentacle-type polymers, polyelectrolyte multilayers, polysaccharides, phospholipids, and proteins. This review, while considering the development of novel OT-CEC coating materials, specifically examines different immobilization or coating methodologies and approaches and also discusses the separation mechanisms that occur with these new materials. These OT-CEC coatings are intended mainly to separate low molecular weight molecules relevant to the pharmaceutical, agricultural, and food industries as well as for use in environmental monitoring.
Collapse
Affiliation(s)
- Faustino M Tarongoy
- Australian Centre for Research on Separation Science, School of Physical Sciences - Chemistry, University of Tasmania, Hobart, Tasmania, Australia
| | - Paul R Haddad
- Australian Centre for Research on Separation Science, School of Physical Sciences - Chemistry, University of Tasmania, Hobart, Tasmania, Australia
| | - Reinhard I Boysen
- Australian Centre for Research on Separation Science, School of Chemistry, Monash University, Melbourne, Victoria, Australia
| | - Milton T W Hearn
- Australian Centre for Research on Separation Science, School of Chemistry, Monash University, Melbourne, Victoria, Australia
| | - Joselito P Quirino
- Australian Centre for Research on Separation Science, School of Physical Sciences - Chemistry, University of Tasmania, Hobart, Tasmania, Australia
| |
Collapse
|
60
|
Zhang Y, Wang W, Xiao X, Jia L. Separation of monoclonal antibody charge state variants by open tubular capillary electrochromatography with immobilised protein as stationary phase. J Chromatogr A 2016; 1466:180-8. [DOI: 10.1016/j.chroma.2016.09.008] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2016] [Revised: 09/01/2016] [Accepted: 09/02/2016] [Indexed: 11/25/2022]
|
61
|
Štěpánová S, Kašička V. Recent applications of capillary electromigration methods to separation and analysis of proteins. Anal Chim Acta 2016; 933:23-42. [DOI: 10.1016/j.aca.2016.06.006] [Citation(s) in RCA: 78] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2016] [Revised: 05/10/2016] [Accepted: 06/03/2016] [Indexed: 10/21/2022]
|
62
|
Poly(N,N-Dimethylacrylamide)-Based Coatings to Modulate Electroosmotic Flow and Capillary Surface Properties for Protein Analysis. Methods Mol Biol 2016. [PMID: 27473485 DOI: 10.1007/978-1-4939-4014-1_9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
Abstract
Capillary electrophoresis (CE) is one of the most powerful techniques for the separation of biomolecules. However, the separation efficiency of proteins in CE is often compromised by their tendency to interact with the silanol groups on the surface of the inner capillary and by an uncontrolled electroosmotic flow. Herein, we report on the use of novel hydrophilic polymeric coatings that can modulate the properties of the capillary walls. The novelty of these poly(N,N-dimethylacrylamide)-based copolymers relies on the simultaneous presence of chemically reactive groups (N-acryloyloxysuccinimide and glycidyl methacrylate) and silane groups in the backbone, which results in highly stable films due to the covalent reaction between the polymer and the glass silanols. A careful optimization of monomer concentration confers anti-fouling properties to the polymer coatings, and thus allows for highly efficient acidic and alkaline protein separations. Furthermore, the presence of these monomers makes it possible to modulate the electroosmotic flow from negligible to reduced values, depending on the desired application.
Collapse
|
63
|
Al-Hossaini AM, Suntornsuk L, Lunte SM. Separation of dynorphin peptides by capillary electrochromatography using a polydiallyldimethylammonium chloride gold nanoparticle-modified capillary. Electrophoresis 2016; 37:2297-304. [PMID: 27130293 DOI: 10.1002/elps.201600006] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2016] [Revised: 04/03/2016] [Accepted: 04/10/2016] [Indexed: 02/05/2023]
Abstract
Dynorphin A (Dyn A) is an endogenous opioid peptide found in blood and central nervous system tissue at very low concentrations. Elevated levels of Dyn A due to different disease states, for example neurodegenerative disease, have been linked to toxic nonopioid activity. CE is a powerful technique that can achieve high-efficiency separations of charged analytes. However, CE has limited use for the analysis of basic proteins and peptides, due to their adsorption onto the inner surface of the fused silica at pHs below their pI. This adsorption can lead to a loss of efficiency, irreproducibility of migration times, and peak tailing. To obviate this problem, a polydiallyldimethylammonium chloride-stabilized gold nanoparticle-coated capillary was investigated for the separation of dynorphin metabolites. The positively charged gold nanoparticles (GNP) minimized unwanted adsorption of the positively charged peptides onto the surface of the fused-silica capillary. Separation efficiency and resolution for opioid peptides Dyn A (1-6), Dyn A (1-7), Dyn A (1-8), Dyn A (1-11), and leu-enkephalin on the GNP-coated capillary column were evaluated under different experimental parameters. The best separation of Dyn A (1-17) and its fragments was achieved using a BGE that consists of 40 mM sodium acetate buffer (pH 5) containing 5% GNP, a field strength of -306 V/cm, and a 75 μm id capillary. The developed method was applied to the separation of tryptic peptide fragments of dynorphin A (1-17).
Collapse
Affiliation(s)
- Abdullah M Al-Hossaini
- Department of Pharmaceutical Chemistry, The University of Kansas, Lawrence, KS, USA.,Ralph N. Adams Institute for Bioanalytical Chemistry, The University of Kansas, Lawrence, KS, USA
| | - Leena Suntornsuk
- Ralph N. Adams Institute for Bioanalytical Chemistry, The University of Kansas, Lawrence, KS, USA.,Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Mahidol University, Bangkok, Thailand
| | - Susan M Lunte
- Department of Pharmaceutical Chemistry, The University of Kansas, Lawrence, KS, USA. .,Department of Chemistry, The University of Kansas, Lawrence, KS, USA. .,Ralph N. Adams Institute for Bioanalytical Chemistry, The University of Kansas, Lawrence, KS, USA.
| |
Collapse
|
64
|
Bacterial surface layer proteins as a novel capillary coating material for capillary electrophoretic separations. Anal Chim Acta 2016; 923:89-100. [DOI: 10.1016/j.aca.2016.04.005] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2016] [Revised: 03/31/2016] [Accepted: 04/02/2016] [Indexed: 11/22/2022]
|
65
|
Znaleziona J, Drahoňovský D, Drahoš B, Ševčík J, Maier V. Novel cationic coating agent for protein separation by capillary electrophoresis(†). J Sep Sci 2016; 39:2406-12. [PMID: 27120584 DOI: 10.1002/jssc.201501349] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2015] [Revised: 04/13/2016] [Accepted: 04/14/2016] [Indexed: 11/08/2022]
Abstract
A novel positively charged surfactant N-dodecyl-N,N-dimethyl-(1,2-propandiol) ammonium chloride was used for the dynamic coating of the inner wall of a silica capillary. This paper covers the evaluation of dynamic coating and study of the influence of the analysis conditions for the magnitude and direction of electroosmotic flow as well as for the effective and selective separation of chosen proteins (ribonuclease A, cytochrome c, lysozyme, and myoglobin). The concentration of 0.1 mM of N-dodecyl-N,N-dimethyl-(1,2-propandiol) ammonium chloride enabled the reversal of the electro-osmotic flow, however, to separate basic as well as neutral proteins the higher concentration of the studied surfactant was necessary. The final conditions for the separation of studied proteins were set at 100 mM sodium acetate pH 5.5 with 10.0 mM of the studied surfactant. The results were also compared with those of two commercially available cationic surfactants, cetyltrimethylammonium bromide and dodecyltrimethylammonium bromide. Additionally, the developed method for protein separation was applied for the determination of lysozyme in a cheese sample. The limits of detection and quantification of lysozyme were 0.9 and 3.0 mg/L, respectively. The mean concentration of lysozyme found in the cheese sample was 167.3 ± 10.3 mg/kg.
Collapse
Affiliation(s)
- Joanna Znaleziona
- Regional Centre of Advanced Technologies and Materials Department of Analytical Chemistry, Faculty of Science, Palacký University in Olomouc, Olomouc, Czech Republic
| | - Dušan Drahoňovský
- Department of Organic Chemistry, Faculty of Science, Charles University in Prague, Prague 2, Czech Republic
| | - Bohuslav Drahoš
- Department of Inorganic Chemistry, Faculty of Science, Palacký University in Olomouc, Olomouc, Czech Republic
| | - Juraj Ševčík
- Regional Centre of Advanced Technologies and Materials Department of Analytical Chemistry, Faculty of Science, Palacký University in Olomouc, Olomouc, Czech Republic
| | - Vítězslav Maier
- Regional Centre of Advanced Technologies and Materials Department of Analytical Chemistry, Faculty of Science, Palacký University in Olomouc, Olomouc, Czech Republic
| |
Collapse
|
66
|
Danel C, Melnyk P, Azaroual N, Larchanché PE, Goossens JF, Vaccher C. Evaluation of three neutral capillary coatings for the determination of analyte-cyclodextrin binding constants by affinity capillary electrophoresis. Application to N,N'-disubstituted piperazine derivatives. J Chromatogr A 2016; 1455:163-171. [PMID: 27286645 DOI: 10.1016/j.chroma.2016.05.090] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2016] [Revised: 05/23/2016] [Accepted: 05/26/2016] [Indexed: 01/08/2023]
Abstract
The performances of three neutral static coatings (hydroxypropyl cellulose, polyethylene oxide and poly(N,N-dimethylacrylamide) have been evaluated in order to determine the binding constants of the complexes formed between four polycationic compounds (piperazine derivatives) and four cyclodextrins of pharmaceutical interest (β-CD, HP-β-CD, Me-β-CD and sulfobutyl ether-β-CD) by affinity capillary electrophoresis. The physically-adsorbed poly(N,N-dimethylacrylamide) coating proves to be the more efficient to mask the silanol groups of the capillary wall since the lowest electroosmotic flow was measured for this coating. Moreover, it drastically reduces the adsorption of the compounds since it allows a correct repeatability of their migration time, higher efficiencies of the peaks and no baseline shift. Then, it was verified for four complexes that this coating allows a correct determination of the binding constants avoiding the CD adsorption which is responsible of an undervaluation of binding constants. The highest binding constants are obtained using the anionic sulfobutyl ether-β-CD (SBE-β-CD). The structure of the complex formed between the tacrine derivative and the SBE-β-CD was further investigated through 2D ROESY NMR experiments and structure-binding constant relationships. Results suggest that the inclusion in the SBE-β-CD cavity occurs through the aliphatic ring portion of the tacrine moiety.
Collapse
Affiliation(s)
- Cécile Danel
- Univ. Lille, CHU Lille, EA 7365 GRITA Groupe de Recherche sur les formes Injectables et les Technologies Associées, F-59000 Lille, France.
| | - Patricia Melnyk
- Univ. Lille, Inserm, CHU Lille, UMR-S 1172 JPArc Centre de Recherche Jean-Pierre AUBERT Neurosciences et Cancer, F-59000 Lille, France.
| | - Nathalie Azaroual
- Univ. Lille, CHU Lille, EA 7365 GRITA Groupe de Recherche sur les formes Injectables et les Technologies Associées, F-59000 Lille, France.
| | - Paul-Emmanuel Larchanché
- Univ. Lille, Inserm, CHU Lille, UMR-S 1172 JPArc Centre de Recherche Jean-Pierre AUBERT Neurosciences et Cancer, F-59000 Lille, France.
| | - Jean-François Goossens
- Univ. Lille, CHU Lille, EA 7365 GRITA Groupe de Recherche sur les formes Injectables et les Technologies Associées, F-59000 Lille, France.
| | - Claude Vaccher
- Univ. Lille, CHU Lille, EA 7365 GRITA Groupe de Recherche sur les formes Injectables et les Technologies Associées, F-59000 Lille, France.
| |
Collapse
|
67
|
Leitner M, Stock LG, Traxler L, Leclercq L, Bonazza K, Friedbacher G, Cottet H, Stutz H, Ebner A. Mapping molecular adhesion sites inside SMIL coated capillaries using atomic force microscopy recognition imaging. Anal Chim Acta 2016; 930:39-48. [PMID: 27265903 DOI: 10.1016/j.aca.2016.05.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2015] [Revised: 04/29/2016] [Accepted: 05/01/2016] [Indexed: 10/21/2022]
Abstract
Capillary zone electrophoresis (CZE) is a powerful analytical technique for fast and efficient separation of different analytes ranging from small inorganic ions to large proteins. However electrophoretic resolution significantly depends on the coating of the inner capillary surface. High technical efforts like Successive Multiple Ionic Polymer Layer (SMIL) generation have been taken to develop stable coatings with switchable surface charges fulfilling the requirements needed for optimal separation. Although the performance can be easily proven in normalized test runs, characterization of the coating itself remains challenging. Atomic force microscopy (AFM) allows for topographical investigation of biological and analytical relevant surfaces with nanometer resolution and yields information about the surface roughness and homogeneity. Upgrading the scanning tip to a molecular biosensor by adhesive molecules (like partly inverted charged molecules) allows for performing topography and recognition imaging (TREC). As a result, simultaneously acquired sample topography and adhesion maps can be recorded. We optimized this technique for electrophoresis capillaries and investigated the charge distribution of differently composed and treated SMIL coatings. By using the positively charged protein avidin as a single molecule sensor, we compared these SMIL coatings with respect to negative charges, resulting in adhesion maps with nanometer resolution. The capability of TREC as a functional investigation technique at the nanoscale was successfully demonstrated.
Collapse
Affiliation(s)
- Michael Leitner
- Institute of Biophysics, Johannes Kepler University Linz, Gruberstrasse 40, 4020 Linz, Austria
| | - Lorenz G Stock
- Division of Chemistry and Bioanalytics, Department of Molecular Biology, University Salzburg, Hellbrunnerstrasse 34, 5020 Salzburg, Austria; Christian Doppler Laboratory for Innovative Tools for the Characterization of Biosimilars, University Salzburg, Hellbrunnerstrasse 34, 5020 Salzburg, Austria
| | - Lukas Traxler
- Institute of Biophysics, Johannes Kepler University Linz, Gruberstrasse 40, 4020 Linz, Austria
| | - Laurent Leclercq
- Institut des Biomolécules Max Mousseron (IBMM, UMR 5247, CNRS, Université de Montpellier, Ecole Nationale Supérieure de Chimie de Montpellier), Place Eugène Bataillon, CC 1706, 34095 Montpellier, France
| | - Klaus Bonazza
- Institute of Chemical Technologies and Analytics, Vienna University of Technology, Getreidemarkt 9/164, 1060 Vienna, Austria
| | - Gernot Friedbacher
- Institute of Chemical Technologies and Analytics, Vienna University of Technology, Getreidemarkt 9/164, 1060 Vienna, Austria
| | - Hervé Cottet
- Institut des Biomolécules Max Mousseron (IBMM, UMR 5247, CNRS, Université de Montpellier, Ecole Nationale Supérieure de Chimie de Montpellier), Place Eugène Bataillon, CC 1706, 34095 Montpellier, France
| | - Hanno Stutz
- Division of Chemistry and Bioanalytics, Department of Molecular Biology, University Salzburg, Hellbrunnerstrasse 34, 5020 Salzburg, Austria; Christian Doppler Laboratory for Innovative Tools for the Characterization of Biosimilars, University Salzburg, Hellbrunnerstrasse 34, 5020 Salzburg, Austria
| | - Andreas Ebner
- Institute of Biophysics, Johannes Kepler University Linz, Gruberstrasse 40, 4020 Linz, Austria.
| |
Collapse
|
68
|
Nowak PM, Woźniakiewicz M, Garnysz M, Kościelniak P. A comparative study of various physicochemically modified capillaries used in CE technique for the three distinct analytical purposes. J Chromatogr B Analyt Technol Biomed Life Sci 2016; 1020:134-41. [DOI: 10.1016/j.jchromb.2016.03.037] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2015] [Revised: 03/19/2016] [Accepted: 03/24/2016] [Indexed: 10/22/2022]
|
69
|
Beneito-Cambra M, Anres P, Vial J, Gareil P, Delaunay N. Stability and effectiveness of linear polyacrylamide capillary coating to suppress EOF in acidic media in the presence of surfactants, ionic liquids and organic modifiers. Talanta 2016; 150:546-52. [DOI: 10.1016/j.talanta.2015.12.070] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2015] [Revised: 12/22/2015] [Accepted: 12/26/2015] [Indexed: 11/25/2022]
|
70
|
Wells SS, De La Toba E, Harrison CR. Metal cation control of electroosmotic flow magnitude in phospholipid-coated capillaries. Electrophoresis 2016; 37:1303-9. [PMID: 26960035 DOI: 10.1002/elps.201600012] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2016] [Revised: 02/23/2016] [Accepted: 02/25/2016] [Indexed: 11/09/2022]
Abstract
CZE has become widespread for the separation and analysis of biomolecules such as proteins and peptides, due to factors such as, the speed of the separations, low sample volume, and high resolution associated with the technique. However, the separation of biomolecules by CZE does present a significant challenge due to the electrostatic attraction and adsorption of cationic, or cation containing, biomolecules to the capillary surface. To that end numerous methods have been developed to passivate, or protect the surface, in order to prevent the adsorption of analytes. Yet, in the process of protecting the capillary surface, the potential for further modification of the EOF, a factor crucial to effective analyte resolution, is greatly diminished. In seeking to overcome this limitation we have explored the potential of incorporating a range of metal cations into a phospholipid bilayer capillary coating. It has previously been established that the inclusion of calcium into the separation buffer with a phospholipid coating will reverse the EOF in the capillary. Here, we present our investigation of a broader range of metal cations included in the separation buffer (Ca(2+) , Mg(2+) , Co(2+) , Ni(2+) , Sr(2+) , Ba(2+) , and Ce(3+) ) revealing that the choice of metal cation can drastically influence the EOF, with observed values between -3.80 × 10(-4) and -5.74 × 10(-5) cm(2) /V·s.
Collapse
Affiliation(s)
- Shane S Wells
- Department of Chemistry and Biochemistry, San Diego State University, San Diego, CA, USA
| | - Eduardo De La Toba
- Department of Chemistry and Biochemistry, San Diego State University, San Diego, CA, USA
| | - Christopher R Harrison
- Department of Chemistry and Biochemistry, San Diego State University, San Diego, CA, USA
| |
Collapse
|
71
|
Álvarez-Martos I, Alonso-Bartolomé R, Mulas Hernández V, Anillo A, Costa-García A, García Alonso FJ, Fernández-Abedul MT. Poly(glycidyl methacrylate) as a tunable platform of modifiers for microfluidic devices. REACT FUNCT POLYM 2016. [DOI: 10.1016/j.reactfunctpolym.2016.01.002] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
|
72
|
Influence of the ionic strength of acidic background electrolytes on the separation of proteins by capillary electrophoresis. J Chromatogr A 2016; 1432:145-51. [DOI: 10.1016/j.chroma.2015.12.060] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2015] [Revised: 12/20/2015] [Accepted: 12/21/2015] [Indexed: 12/16/2022]
|
73
|
Jaccoulet E, Smadja C, Taverna M. Quality Control of Therapeutic Monoclonal Antibodies at the Hospital After Their Compounding and Before Their Administration to Patients. Methods Mol Biol 2016; 1466:179-184. [PMID: 27473490 DOI: 10.1007/978-1-4939-4014-1_14] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Monoclonal antibodies (mAbs) are widely used in cancer therapy and recently many new mAbs have gained EMA and FDA approvals for oncology indications. Here we describe a highly reproducible CZE method, relying on a cationic coating allowing separation and identification of a complex mixture of four compounded mAbs widely used in cancer therapy (cetuximab, rituximab, bevacizumab, and trastuzumab).
Collapse
Affiliation(s)
- Emmanuel Jaccoulet
- Institut Galien Paris-Sud, UMR 8612, Proteins and Nanotechnology in Analytical Science, CNRS, Univ Paris-Sud, Univ Paris-Saclay, 5 rue Jean-Baptiste Clément, 92296, Châtenay-Malabry, France
- Hôpital Européen Georges Pompidou, Paris, France
| | - Claire Smadja
- Institut Galien Paris-Sud, UMR 8612, Proteins and Nanotechnology in Analytical Science, CNRS, Univ Paris-Sud, Univ Paris-Saclay, 5 rue Jean-Baptiste Clément, 92296, Châtenay-Malabry, France.
| | - Myriam Taverna
- Institut Galien Paris-Sud, UMR 8612, Proteins and Nanotechnology in Analytical Science (PNAS), CNRS, Univ. Paris-Sud, Université Paris-Saclay, Châtenay-Malabry, France
| |
Collapse
|
74
|
Domínguez-Vega E, Haselberg R, Somsen GW. Capillary Zone Electrophoresis-Mass Spectrometry of Intact Proteins. Methods Mol Biol 2016; 1466:25-41. [PMID: 27473479 DOI: 10.1007/978-1-4939-4014-1_3] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Capillary electrophoresis (CE) coupled with mass spectrometry (MS) has proven to be a powerful analytical tool for the characterization of intact proteins. It combines the high separation efficiency, short analysis time, and versatility of CE with the mass selectivity and sensitivity offered by MS detection. This chapter focuses on important practical considerations when applying CE-MS for the analysis of intact proteins. Technological aspects with respect to the use of CE-MS interfaces and application of noncovalent capillary coatings preventing protein adsorption are treated. Critical factors for successful protein analysis are discussed and four typical CE-MS systems are described demonstrating the characterization of different types of intact proteins by CE-MS. These methodologies comprise the use of sheath-liquid and sheathless CE-MS interfaces, and various types of noncovalent capillary coatings allowing efficient and reproducible protein separations. The discussion includes the analysis of lysozyme-drug conjugates and the therapeutic proteins human growth hormone, human interferon-β-1a, and human erythropoietin.
Collapse
Affiliation(s)
- Elena Domínguez-Vega
- Division of BioAnalytical Chemistry, VU University, de Boelelaan 1083, 1081 HV, Amsterdam, The Netherlands
| | - Rob Haselberg
- Division of BioAnalytical Chemistry, VU University, de Boelelaan 1083, 1081 HV, Amsterdam, The Netherlands
| | - Govert W Somsen
- Division of BioAnalytical Chemistry, VU University, de Boelelaan 1083, 1081 HV, Amsterdam, The Netherlands.
| |
Collapse
|
75
|
Neuberger S, Rafai A, Neusüß C. Screening of Small Intact Proteins by Capillary Electrophoresis Electrospray Ionization-Mass Spectrometry (CE-ESI-MS). Methods Mol Biol 2016; 1466:43-56. [PMID: 27473480 DOI: 10.1007/978-1-4939-4014-1_4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Capillary electrophoresis (CE) has been shown to be a suitable separation technique for complex samples. Combined with electrospray ionization-mass spectrometry (ESI-MS), it is a powerful tool offering the opportunity of high selectivity and sensitivity combined with the possibility to identify and characterize intact proteins. In this protocol, we demonstrate a screening method for intact proteins based on capillary zone electrophoresis (CZE) separation coupled with online mass spectrometric detection. In order to avoid protein-wall interactions, a neutral coated capillary is used to create a universal method for proteins with both low and high electrophoretic mobilities. In addition, we show the successful validation and application of this screening method for a set of eight standard proteins and the glycoprotein erythropoietin.
Collapse
Affiliation(s)
- Sabine Neuberger
- Department of Chemistry, Aalen University, Beethovenstraβe 1, Aalen, D-73430, Germany
| | | | - Christian Neusüß
- Department of Chemistry, Aalen University, Beethovenstraβe 1, Aalen, D-73430, Germany.
| |
Collapse
|
76
|
Amini A. Analysis of Somatropin by Double-Injection Capillary-Zone Electrophoresis in Polybrene/Chondroitin Sulfate A Double-Coated Capillaries. Methods Mol Biol 2016; 1466:93-105. [PMID: 27473484 DOI: 10.1007/978-1-4939-4014-1_8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Purity determination of somatropin as a recombinant protein is important to ensure its safety and quality. This is carried out by capillary zone electrophoresis in double-injection mode using polybrene/chondroitin sulfate A double-coated capillaries. Modification of the capillary wall eliminates protein-wall interactions which results in improved accuracy and precision of the determinations. In the double-injection mode two somatropin samples are analyzed within a single electrophoretic run. Prior to the second injection, the first injected plug is electrophoresed for a predetermined time period in order to adjust the inter-plug distance. Here, the principle for the separation of somatropin charge variants is described.
Collapse
Affiliation(s)
- Ahmad Amini
- Medical Products Agency (MPA), Box 26, Dag Hammarskjölds väg 42, Uppsala, 751 03, Sweden.
- Division of Analytical Pharmaceutical Chemistry, Biomedical Centre, Uppsala University, Box 574, Uppsala, 751 23, Sweden.
| |
Collapse
|
77
|
Pattky M, Barkovits K, Marcus K, Weiergräber OH, Huhn C. Statically Adsorbed Coatings for High Separation Efficiency and Resolution in CE-MS Peptide Analysis: Strategies and Implementation. Methods Mol Biol 2016; 1483:53-75. [PMID: 27645731 DOI: 10.1007/978-1-4939-6403-1_4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Coatings are necessary to prevent protein and peptide adsorption to the capillary surface and obtain high intermediate precision. In this protocol, we first present our basic strategy to address peptide separation using three different coatings: one neutral and two cationic coatings, the latter largely differing in their induced electroosmotic mobility. In detail, we will describe how we apply the statically adsorbed coatings to obtain very high plate numbers and high repeatability.With some model examples, we clearly describe the scope of the method for the analysis of peptide samples: tryptic digests are addressed as well as small glycoproteins and glycopeptides largely differing in their effective electrophoretic mobility. We also show that the method is suitable for a fast screening of peptide samples despite a high matrix load comprising of up to 500 mmol/L sodium chloride. We demonstrate that this basic CE-MS method is rather independent of the polarity of the analytes with a very fast near-baseline separation of very hydrophobic Aβ peptides related to the onset of Alzheimer's disease. These examples will give an impression, which coating is most suitable for a specific analytical application.Special attention is paid to difficult aspects of the coating procedure and the CE-MS method, e.g., the potential of cross-contamination when changing the coatings.
Collapse
Affiliation(s)
- Martin Pattky
- Institute for Physical and Theoretical Chemistry, Eberhard Karls Universität Tübingen, Auf der Morgenstelle 18, Tübingen, 72076, Germany
| | - Katalin Barkovits
- Functional Proteomics, Medical Proteome-Center, Ruhr-Universität Bochum, Bochum, Germany
| | - Katrin Marcus
- Functional Proteomics, Medical Proteome-Center, Ruhr-Universität Bochum, Bochum, Germany
| | - Oliver H Weiergräber
- Institute of Complex Systems, ICS-6: Structural Biochemistry, Forschungszentrum Jülich, Jülich, Germany
| | - Carolin Huhn
- Institute for Physical and Theoretical Chemistry, Eberhard Karls Universität Tübingen, Auf der Morgenstelle 18, Tübingen, 72076, Germany.
| |
Collapse
|
78
|
Duša F, Witos J, Karjalainen E, Viitala T, Tenhu H, Wiedmer SK. Novel cationic polyelectrolyte coatings for capillary electrophoresis. Electrophoresis 2015; 37:363-71. [DOI: 10.1002/elps.201500275] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2015] [Revised: 09/17/2015] [Accepted: 10/05/2015] [Indexed: 01/07/2023]
Affiliation(s)
- Filip Duša
- Department of Chemistry; University of Helsinki; Helsinki Finland
| | - Joanna Witos
- Department of Chemistry; University of Helsinki; Helsinki Finland
| | - Erno Karjalainen
- Laboratory of Polymer chemistry, Department of Chemistry; University of Helsinki; Helsinki Finland
| | - Tapani Viitala
- Centre for Drug Research, Division of Pharmaceutical Biosciences, Faculty of Pharmacy; University of Helsinki; Helsinki Finland
| | - Heikki Tenhu
- Laboratory of Polymer chemistry, Department of Chemistry; University of Helsinki; Helsinki Finland
| | | |
Collapse
|
79
|
Monteferrante M, Sola L, Cretich M, Chiari M, Marini Bettolo Marconi U, Melchionna S. Controlling electroosmotic flows by polymer coatings: A joint experimental-theoretical investigation. J Chem Phys 2015; 143:184907. [DOI: 10.1063/1.4934998] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Affiliation(s)
- Michele Monteferrante
- Consiglio Nazionale delle Ricerche, Istituto di Chimica del Riconoscimento Molecolare (ICRM-CNR), Via Mario Bianco, 20131 Milan, Italy
| | - Laura Sola
- Consiglio Nazionale delle Ricerche, Istituto di Chimica del Riconoscimento Molecolare (ICRM-CNR), Via Mario Bianco, 20131 Milan, Italy
| | - Marina Cretich
- Consiglio Nazionale delle Ricerche, Istituto di Chimica del Riconoscimento Molecolare (ICRM-CNR), Via Mario Bianco, 20131 Milan, Italy
| | - Marcella Chiari
- Consiglio Nazionale delle Ricerche, Istituto di Chimica del Riconoscimento Molecolare (ICRM-CNR), Via Mario Bianco, 20131 Milan, Italy
| | - Umberto Marini Bettolo Marconi
- Scuola di Scienze e Tecnologie, Università di Camerino, Via Madonna delle Carceri, 62032 Camerino, Italy and INFN Perugia, Perugia, Italy
| | - Simone Melchionna
- Department of Physics, Consiglio Nazionale delle Ricerche, Istituto Sistemi Complessi (ISC-CNR), University La Sapienza, P. le A. Moro 2, 00185 Rome, Italy
| |
Collapse
|
80
|
Geiger M, Harstad RK, Bowser MT. Effect of Surface Adsorption on Temporal and Spatial Broadening in Micro Free Flow Electrophoresis. Anal Chem 2015; 87:11682-90. [DOI: 10.1021/acs.analchem.5b02262] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Matthew Geiger
- Department of Chemistry, University of Minnesota, 207 Pleasant
Street SE, Minneapolis, Minnesota 55455, United States
| | - Rachel K. Harstad
- Department of Chemistry, University of Minnesota, 207 Pleasant
Street SE, Minneapolis, Minnesota 55455, United States
| | - Michael T. Bowser
- Department of Chemistry, University of Minnesota, 207 Pleasant
Street SE, Minneapolis, Minnesota 55455, United States
| |
Collapse
|
81
|
One step physically adsorbed coating of silica capillary with excellent stability for the separation of basic proteins by capillary zone electrophoresis. Talanta 2015; 144:110-4. [DOI: 10.1016/j.talanta.2015.05.080] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2015] [Revised: 05/27/2015] [Accepted: 05/29/2015] [Indexed: 11/21/2022]
|
82
|
Simultaneous separation of acidic and basic proteins using gemini pyrrolidinium surfactants and hexafluoroisopropanol as dynamic coating additives in capillary electrophoresis. J Chromatogr A 2015; 1412:151-8. [DOI: 10.1016/j.chroma.2015.08.020] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2015] [Revised: 08/08/2015] [Accepted: 08/10/2015] [Indexed: 11/18/2022]
|
83
|
Zhang C, Chen L, Tan L, Zheng X, Wang Y. Poly(dopamine)-assisted preparation of star poly(ethylene glycol)-based coatings: A detailed study of their protein resistance and application in CE. REACT FUNCT POLYM 2015. [DOI: 10.1016/j.reactfunctpolym.2015.05.009] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
84
|
Xiao X, Wang W, Chen J, Jia L. Polydopamine-coated open tubular column for the separation of proteins by capillary electrochromatography. J Sep Sci 2015; 38:2893-9. [DOI: 10.1002/jssc.201500315] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2015] [Revised: 05/12/2015] [Accepted: 05/14/2015] [Indexed: 11/08/2022]
Affiliation(s)
- Xing Xiao
- Ministry of Education Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics; South China Normal University; Guangzhou China
| | - Wentao Wang
- Ministry of Education Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics; South China Normal University; Guangzhou China
| | - Jia Chen
- Ministry of Education Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics; South China Normal University; Guangzhou China
| | - Li Jia
- Ministry of Education Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics; South China Normal University; Guangzhou China
| |
Collapse
|
85
|
Jaccoulet E, Smadja C, Prognon P, Taverna M. Capillary electrophoresis for rapid identification of monoclonal antibodies for routine application in hospital. Electrophoresis 2015; 36:2050-6. [PMID: 25964136 DOI: 10.1002/elps.201400603] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2014] [Revised: 03/25/2015] [Accepted: 04/25/2015] [Indexed: 11/08/2022]
Abstract
mAbs are widely used in cancer therapy. Their compounding, performed just before their administration to patients, is executed in a production unit of the hospital. Identification of these drugs, individually prepared in bags for infusion before patient administration, is of paramount importance to detect potential mistakes during compounding stage. A fast and reliable analytical method based on CZE combined to a cationic capillary coating (hexadimethrine bromide) was developed for identification of the most widely used compounded therapeutic for cancer therapy (bevacizumab, cetuximab, rituximab, and trastuzumab). Considering the high structural and physico-chemical similarities of these mAbs, an extensive optimization of the BGE composition has been performed. The addition of perchlorate ions and polysorbate in the BGE greatly increased the resolution. To validate the method, an internal standard was used and the relative migration times (RTm) were estimated. Very satisfactory RSDs of the RTm for rituximab (0.76%), cetuximab (0.46%), bevacizumab (0.31%), and trastuzumab (0.60%) were obtained. The intraday and interday RSD of the method were less than 0.32 and 1.3%, respectively for RTm. Significant differences between theses RTms have been demonstrated allowing mAbs identification. Finally, accurate mAbs identification has been demonstrated by a blind test.
Collapse
Affiliation(s)
- Emmanuel Jaccoulet
- Institut Galien Paris Sud, Université Paris Sud, Châtenay-Malabry, France.,CNRS UMR 8612, Châtenay-Malabry, France.,Hôpital Européen Georges Pompidou, Service Pharmacie (AP-HP), Paris, France
| | - Claire Smadja
- Institut Galien Paris Sud, Université Paris Sud, Châtenay-Malabry, France.,CNRS UMR 8612, Châtenay-Malabry, France
| | - Patrice Prognon
- Hôpital Européen Georges Pompidou, Service Pharmacie (AP-HP), Paris, France
| | - Myriam Taverna
- Institut Galien Paris Sud, Université Paris Sud, Châtenay-Malabry, France.,CNRS UMR 8612, Châtenay-Malabry, France
| |
Collapse
|
86
|
Bekri S, Leclercq L, Cottet H. Polyelectrolyte multilayer coatings for the separation of proteins by capillary electrophoresis: Influence of polyelectrolyte nature and multilayer crosslinking. J Chromatogr A 2015; 1399:80-7. [DOI: 10.1016/j.chroma.2015.04.033] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2015] [Revised: 04/17/2015] [Accepted: 04/20/2015] [Indexed: 10/23/2022]
|
87
|
Acunha T, Ibáñez C, Pascual Reguera MI, Sarò M, Navarro R, Alfonso Redondo J, Reinecke H, Gallardo A, Simó C, Cifuentes A. Potential of prodendronic polyamines with modulated segmental charge density as novel coating for fast and efficient analysis of peptides and basic proteins by CE and CE-MS. Electrophoresis 2015; 36:1564-71. [DOI: 10.1002/elps.201400576] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2014] [Revised: 03/12/2015] [Accepted: 03/12/2015] [Indexed: 01/13/2023]
Affiliation(s)
- Tanize Acunha
- Laboratory of Foodomics; Institute of Food Science Research (CIAL); CSIC; Campus de Cantoblanco Madrid Spain
- CAPES Foundation; Ministry of Education of Brazil; Brasília DF Brazil
| | - Clara Ibáñez
- Laboratory of Foodomics; Institute of Food Science Research (CIAL); CSIC; Campus de Cantoblanco Madrid Spain
| | | | - Mariagiovanna Sarò
- Dipartimento di Scienze del Farmaco e dei Prodotti per la Salute, Facoltà di Farmacia; Università degli Studi di Messina; Messina Italy
| | - Rodrigo Navarro
- Instituto de Ciencia y Tecnología de Polímeros; ICTP-CSIC; Madrid
| | | | - Helmut Reinecke
- Instituto de Ciencia y Tecnología de Polímeros; ICTP-CSIC; Madrid
| | - Alberto Gallardo
- Instituto de Ciencia y Tecnología de Polímeros; ICTP-CSIC; Madrid
| | - Carolina Simó
- Laboratory of Foodomics; Institute of Food Science Research (CIAL); CSIC; Campus de Cantoblanco Madrid Spain
| | - Alejandro Cifuentes
- Laboratory of Foodomics; Institute of Food Science Research (CIAL); CSIC; Campus de Cantoblanco Madrid Spain
| |
Collapse
|
88
|
A Comprehensive Study of Silanization and Co-Condensation for Straightforward Single-Step Covalent Neutral Capillary Coating. Chromatographia 2015. [DOI: 10.1007/s10337-015-2895-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
89
|
Redman EA, Batz NG, Mellors JS, Ramsey JM. Integrated Microfluidic Capillary Electrophoresis-Electrospray Ionization Devices with Online MS Detection for the Separation and Characterization of Intact Monoclonal Antibody Variants. Anal Chem 2015; 87:2264-72. [DOI: 10.1021/ac503964j] [Citation(s) in RCA: 92] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
- Erin A. Redman
- Department of Chemistry, ‡Department of Applied
Physical Sciences, §Department of Biomedical
Engineering, ∥Carolina Center for Genome Sciences, University of North Carolina, Chapel Hill, North Carolina 27599, United States
| | - Nicholas G. Batz
- Department of Chemistry, ‡Department of Applied
Physical Sciences, §Department of Biomedical
Engineering, ∥Carolina Center for Genome Sciences, University of North Carolina, Chapel Hill, North Carolina 27599, United States
| | - J. Scott Mellors
- Department of Chemistry, ‡Department of Applied
Physical Sciences, §Department of Biomedical
Engineering, ∥Carolina Center for Genome Sciences, University of North Carolina, Chapel Hill, North Carolina 27599, United States
| | - J. Michael Ramsey
- Department of Chemistry, ‡Department of Applied
Physical Sciences, §Department of Biomedical
Engineering, ∥Carolina Center for Genome Sciences, University of North Carolina, Chapel Hill, North Carolina 27599, United States
| |
Collapse
|
90
|
YAMAMOTO S, IWATA T, NISHIWAKI K, KINOSHITA M, SUZUKI S. Synthesis of Quaternary Ammonium Derivatives of Cellulose as the Coating Reagents for Capillary Electrophoresis. CHROMATOGRAPHY 2015. [DOI: 10.15583/jpchrom.2015.027] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Affiliation(s)
| | | | | | | | - Shigeo SUZUKI
- Faculty of Pharmaceutical Sciences, Kinki University
| |
Collapse
|
91
|
Zhao D, Wang G, He Z, Wang H, Zhang Q, Li Y. Controllable construction of micro/nanostructured NiO arrays in confined microchannels via microfluidic chemical fabrication for highly efficient and specific absorption of abundant proteins. J Mater Chem B 2015; 3:4272-4281. [DOI: 10.1039/c5tb00324e] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The multiple micro/nanostructured NiO arrays constructed on the inner walls of the microchannels via a simple microfluidic chemical method exhibit highly efficient and specific absorption of abundant proteins.
Collapse
Affiliation(s)
- De Zhao
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials
- College of Materials Science and Engineering
- Donghua University
- People's Republic of China
| | - Gang Wang
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials
- College of Materials Science and Engineering
- Donghua University
- People's Republic of China
| | - Zhongyuan He
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials
- College of Materials Science and Engineering
- Donghua University
- People's Republic of China
| | - Hongzhi Wang
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials
- College of Materials Science and Engineering
- Donghua University
- People's Republic of China
| | - Qinghong Zhang
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials
- College of Materials Science and Engineering
- Donghua University
- People's Republic of China
| | - Yaogang Li
- Engineering Research Center of Advanced Glasses Manufacturing Technology
- MOE
- Donghua University
- People's Republic of China
| |
Collapse
|
92
|
Present state of microchip electrophoresis: state of the art and routine applications. J Chromatogr A 2014; 1382:66-85. [PMID: 25529267 DOI: 10.1016/j.chroma.2014.11.034] [Citation(s) in RCA: 130] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2014] [Revised: 11/07/2014] [Accepted: 11/12/2014] [Indexed: 12/20/2022]
Abstract
Microchip electrophoresis (MCE) was one of the earliest applications of the micro-total analysis system (μ-TAS) concept, whose aim is to reduce analysis time and reagent and sample consumption while increasing throughput and portability by miniaturizing analytical laboratory procedures onto a microfluidic chip. More than two decades on, electrophoresis remains the most common separation technique used in microfluidic applications. MCE-based instruments have had some commercial success and have found application in many disciplines. This review will consider the present state of MCE including recent advances in technology and both novel and routine applications in the laboratory. We will also attempt to assess the impact of MCE in the scientific community and its prospects for the future.
Collapse
|
93
|
Gitlin L, Schulze P, Ohla S, Bongard HJ, Belder D. Surface modification of PDMS microfluidic devices by controlled sulfuric acid treatment and the application in chip electrophoresis. Electrophoresis 2014; 36:449-56. [PMID: 25257973 DOI: 10.1002/elps.201400269] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2014] [Revised: 09/03/2014] [Accepted: 09/04/2014] [Indexed: 01/13/2023]
Abstract
Herein, we present a straightforward surface modification technique for PDMS-based microfluidic devices. The method takes advantage of the high reactivity of concentrated sulfuric acid to enhance the surface properties of PDMS bulk material. This results in alteration of the surface morphology and chemical composition that is in-depth characterized by ATR-FTIR, EDX, SEM, and XPS. In comparison to untreated PDMS, modified substrates exhibit a significantly reduced diffusive uptake of small organic molecules while retaining its low electroosmotic properties. This was demonstrated by exposing the channels of a microfluidic device to concentrated rhodamine B solution followed by fluorescence microscopy. The surface modification procedure was used to improve chip-based electrophoretic separations. Separation efficiencies of FITC-labeled amines/amino acids obtained in treated and untreated PDMS-devices as well as in glass chips were compared. We obtained higher efficiencies in H2 SO4 treated PDMS chips compared to untreated ones but lower efficiencies than those obtained in commercial microfluidic glass devices.
Collapse
Affiliation(s)
- Leonid Gitlin
- Institut für Analytische Chemie, Universität Leipzig, Leipzig, Germany
| | | | | | | | | |
Collapse
|
94
|
Huang D, Yang Q, Jin S, Deng Q, Zhou P. Self-assembly of cellulose nanoparticles as electrolyte additive for capillary electrophoresis separation. J Chromatogr A 2014; 1367:148-53. [DOI: 10.1016/j.chroma.2014.09.032] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2014] [Revised: 09/11/2014] [Accepted: 09/14/2014] [Indexed: 12/30/2022]
|
95
|
Zandkarimi M, Tabrizian K, Darbandi MA, Dahmardeh S. EFFECT OF CYCLODEXTRINS ON THE STABILITY OF BILAYER: A NOVEL ELECTROPHORETIC APPROACH. J LIQ CHROMATOGR R T 2014. [DOI: 10.1080/10826076.2013.840840] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Affiliation(s)
- M. Zandkarimi
- a School of Pharmacy , Zabol University of Medical Sciences , Zabol , Iran
| | - Kaveh Tabrizian
- a School of Pharmacy , Zabol University of Medical Sciences , Zabol , Iran
| | | | - Somayeh Dahmardeh
- a School of Pharmacy , Zabol University of Medical Sciences , Zabol , Iran
| |
Collapse
|
96
|
Kobayashi T, Kan H, Tabata K, Hashimoto M, Tsukagoshi K. Open-Tubular Capillary Chromatoraphy Based on Tube Radial Distribution of the Water-Acetonitrile Containing Sodium Chloride Mixture Carrier Solvents. J LIQ CHROMATOGR R T 2014. [DOI: 10.1080/10826076.2013.873869] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Affiliation(s)
- Tomoya Kobayashi
- a Department of Chemical Engineering and Materials Science, Faculty of Science and Engineering , Doshisha University , Kyotanabe , Kyoto , Japan
| | - Hyo Kan
- a Department of Chemical Engineering and Materials Science, Faculty of Science and Engineering , Doshisha University , Kyotanabe , Kyoto , Japan
| | - Kisuke Tabata
- a Department of Chemical Engineering and Materials Science, Faculty of Science and Engineering , Doshisha University , Kyotanabe , Kyoto , Japan
| | - Masahiko Hashimoto
- a Department of Chemical Engineering and Materials Science, Faculty of Science and Engineering , Doshisha University , Kyotanabe , Kyoto , Japan
| | - Kazuhiko Tsukagoshi
- a Department of Chemical Engineering and Materials Science, Faculty of Science and Engineering , Doshisha University , Kyotanabe , Kyoto , Japan
- b Tube Radial Distribution Phenomenon Research Center , Doshisha University , Kyotanabe , Kyoto , Japan
| |
Collapse
|
97
|
Insight into the stability of poly(diallydimethylammoniumchloride) and polybrene poly cationic coatings in capillary electrophoresis. J Chromatogr A 2014; 1365:226-33. [DOI: 10.1016/j.chroma.2014.09.013] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2014] [Revised: 09/03/2014] [Accepted: 09/05/2014] [Indexed: 12/16/2022]
|
98
|
New insights in carbohydrate-deficient transferrin analysis with capillary electrophoresis–mass spectrometry. Forensic Sci Int 2014; 243:14-22. [DOI: 10.1016/j.forsciint.2014.03.014] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2013] [Revised: 01/21/2014] [Accepted: 03/12/2014] [Indexed: 11/21/2022]
|
99
|
Tan L, Zheng X, Chen L, Wang Y. Quality testing of human albumin by capillary electrophoresis using thermally cross-linked poly(vinyl pyrrolidone)-coated fused-silica capillary. J Sep Sci 2014; 37:2974-82. [DOI: 10.1002/jssc.201400463] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2014] [Revised: 07/26/2014] [Accepted: 07/27/2014] [Indexed: 01/08/2023]
Affiliation(s)
- Lin Tan
- CAS Key Laboratory of Soft Matter Chemistry; Department of Polymer Science and Engineering; University of Science and Technology of China; Hefei P.R. China
| | - Xiajun Zheng
- CAS Key Laboratory of Soft Matter Chemistry; Department of Polymer Science and Engineering; University of Science and Technology of China; Hefei P.R. China
| | - Lijuan Chen
- CAS Key Laboratory of Soft Matter Chemistry; Department of Polymer Science and Engineering; University of Science and Technology of China; Hefei P.R. China
| | - Yanmei Wang
- CAS Key Laboratory of Soft Matter Chemistry; Department of Polymer Science and Engineering; University of Science and Technology of China; Hefei P.R. China
| |
Collapse
|
100
|
Deeb SE, Wätzig H, El-Hady DA, Albishri HM, de Griend CSV, Scriba GKE. Recent advances in capillary electrophoretic migration techniques for pharmaceutical analysis. Electrophoresis 2014; 35:170-89. [PMID: 24395663 DOI: 10.1002/elps.201300411] [Citation(s) in RCA: 66] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2013] [Revised: 10/04/2013] [Accepted: 10/04/2013] [Indexed: 12/31/2022]
Abstract
Since the introduction about 30 years ago, CE techniques have gained a significant impact in pharmaceutical analysis. The present review covers recent advances and applications of CE for the analysis of pharmaceuticals. Both small molecules and biomolecules such as proteins are considered. The applications range from the determination of drug-related substances to the analysis of counterions and the determination of physicochemical parameters. Furthermore, general considerations of CE methods in pharmaceutical analysis are described.
Collapse
Affiliation(s)
- Sami El Deeb
- Drug Analysis and Research Center, Department of Pharmaceutical Chemistry, Al-Azhar University - Gaza, Gaza, Palestine; Institute of Medicinal and Pharmaceutical Chemistry, TU Braunschweig, Braunschweig, Germany
| | | | | | | | | | | |
Collapse
|