51
|
Lercher P, Lunati M, Rordorf R, Landolina M, Badie N, Qu F, Casset C, Ryu K, Ghio S, Singh JP, Leclercq C. Long-term reverse remodeling by cardiac resynchronization therapy with MultiPoint Pacing: A feasibility study of noninvasive hemodynamics-guided device programming. Heart Rhythm 2018; 15:1766-1774. [PMID: 29940305 DOI: 10.1016/j.hrthm.2018.06.032] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2018] [Indexed: 10/28/2022]
Abstract
BACKGROUND Cardiac resynchronization therapy (CRT) with multipoint left ventricular (LV) pacing (MultiPoint Pacing [MPP]) improves acute hemodynamics and chronic outcomes in comparison to conventional biventricular pacing (BiV), though MPP programming questions persist. OBJECTIVES In this multicenter feasibility study, we evaluated the feasibility of using noninvasive systolic blood pressure (SBP) to guide MPP programming and assessed the chronic 6-month echocardiographic CRT response. METHODS Patients implanted with MPP-enabled CRT-defibrillator devices underwent noninvasive hemodynamic assessment (finger arterial pressure) during a pacing protocol that included atrial-only pacing and various BiV and MPP configurations. Each configuration was repeated 4 times, alternating with a reference pacing configuration, to calculate the SBP difference relative to reference (ΔSBP). CRT configurations with the greatest ΔSBP were programmed. An independent core laboratory analyzed baseline and 6-month echocardiograms, with CRT response defined as a 6-month reduction in LV end-systolic volume ≥ 15%. RESULTS Forty-two patients (71% male; LV ejection fraction 30.3% ± 7.5%; QRS duration 161 ± 19 ms; 26% had ischemic cardiomyopathy) were enrolled in 4 European centers. Relative to atrial-only pacing, the best BiV and best MPP configurations produced significant SBP elevations of 3.1 ± 4.2 (P < .01) and 4.1 ± 4.1 mm Hg (P < .01), respectively (BiV vs MPP; P < .01). Greater SBP elevations were associated with the best MPP compared with the best BiV configurations in 29 of 37 patients completing the pacing protocol (78%). Of MPP-programmed patients completing the 6-month follow-up visit, 23 of 27 (85%) were classified as CRT responders (6-month reduction in LV end-systolic volume 37.0% ± 13.6%). CONCLUSION Acute noninvasive hemodynamics after CRT device implantation predominantly favored MPP over BiV programming. MPP programming guided by noninvasive hemodynamics resulted in positive LV structural remodeling.
Collapse
Affiliation(s)
- Peter Lercher
- Department of Cardiology, Medical University Graz, Graz, Austria
| | - Maurizio Lunati
- Cardiac Department, Niguarda Ca' Granda, Granda Hospital, Milan, Italy
| | | | - Maurizio Landolina
- Cardiac Department, Policlinico San Matteo, Pavia, Italy; Cardiology Department, Ospedale Maggiore di Crema, Crema, Italy
| | | | | | | | | | - Stefano Ghio
- Cardiac Department, Policlinico San Matteo, Pavia, Italy
| | - Jagmeet P Singh
- Cardiac Arrhythmia Service, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
| | | |
Collapse
|
52
|
Sadanaga T. Can we “ScREEN” response to cardiac resynchronization therapy by a simple score? Int J Cardiol 2018; 260:105-106. [DOI: 10.1016/j.ijcard.2018.02.100] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/22/2018] [Accepted: 02/23/2018] [Indexed: 11/25/2022]
|
53
|
Abstract
PURPOSE OF REVIEW This review focuses on the current advancements in optimizing patient response to cardiac resynchronization therapy (CRT). RECENT FINDINGS It has been well known that not every patient will derive benefit from CRT, and of those that do, there are varying levels of response. Optimizing CRT begins well before device implant and involves appropriate patient selection and an understanding of the underlying substrate. After implant, there are different CRT device programming options that can be enabled to help overcome barriers as to why a patient may not respond. Given the multifaceted components of optimizing CRT and the complex patient population, multi-subspecialty clinics have been developed bringing together specialists in heart failure, electrophysiology, and imaging. Data as to whether this results in better response rates and outcomes shows promise.
Collapse
|
54
|
Adherence to 2016 European Society of Cardiology guidelines predicts outcome in a large real-world population of heart failure patients requiring cardiac resynchronization therapy. Heart Rhythm 2018; 15:1675-1682. [PMID: 29665405 DOI: 10.1016/j.hrthm.2018.04.011] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/11/2017] [Indexed: 12/28/2022]
Abstract
BACKGROUND Professional guidelines are based on the best available evidence. However, patients treated in clinical practice may differ from those included in reference trials. OBJECTIVE The aim of this study was to evaluate the effects of cardiac resynchronization therapy (CRT) in a large population of patients implanted with a CRT device stratified in accordance with the 2016 European heart failure (HF) guidelines. METHODS We collected data on 930 consecutive patients from the Cardiac Resynchronization Therapy MOdular REgistry. The primary end point was a composite of death and HF hospitalization. RESULTS Five hundred sixty-three (60.5%) patients met class I indications, 145 (15.6%) class IIa, 108 (11.6%) class IIb, and 114 (12.3%) class III. After a median follow-up of 1001 days, 120 (14.7%) patients who had an indication to CRT had died and 71 (8.7%) had been hospitalized for HF. The time to the end point was longer in patients with a class I indication (hazard ratio 0.55; 95% confidence interval 0.39-0.76; P = .0001). After 12 months, left ventricular (LV) end-systolic volume had decreased by ≥15% in 61.5% (320/520) of patients whereas in 57.5% (389/676) of patients the absolute LV ejection fraction improvement was ≥5%. Adherence to class I was also associated with an absolute LV ejection fraction increase of >5% (P = .0142) and an LV end-systolic volume decrease of ≥15% (P = .0055). CONCLUSION In our population, ∼60% of patients underwent implantation according to the 2016 European HF guidelines class I indication. Adherence to class I was associated with a lower death and HF hospitalization rates and better LV reverse remodeling.
Collapse
|
55
|
Leshem E, Suleiman M, Laish-Farkash A, Haim M, Geist M, Luria D, Glikson M, Goldenberg I, Michowitz Y. Impact of quadripolar LV leads on heart failure hospitalization rates among patients implanted with CRT-D: data from the Israeli ICD Registry. J Interv Card Electrophysiol 2017; 51:5-12. [PMID: 29274032 DOI: 10.1007/s10840-017-0305-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/24/2017] [Accepted: 12/14/2017] [Indexed: 10/18/2022]
Abstract
BACKGROUND Cardiac resynchronization therapy (CRT) is an effective treatment for heart failure (HF); however, a third of patients are non-responders. The development of quadripolar left ventricular (LV) lead was shown, mainly in single manufactures' registry, to improve LV remodeling and overall mortality. However, limited reports exist on the impact of quadripolar LV leads on HF hospitalization rates in real-life cohorts. We evaluated the clinical outcomes associated with quadripolar LV leads in a large nation-wide registry including all patients implanted with a cardiac resynchronization therapy with defibrillator (CRT-D). METHODS Between July 2010 and October 2016, 2913 consecutive patients were implanted with a CRT-D and all were prospectively enrolled in the Israeli ICD Registry. Quadripolar LV leads were implanted in 973 (33.4%) patients during this period, and their clinical outcomes were compared to CRT-D recipients implanted with a bipolar LV lead. Primary endpoint was HF hospitalization rate. RESULTS Quadripolar leads were implanted more in patients with non-ischemic cardiomyopathy and for primary prevention indication and less in post-infarction patients and for secondary prevention of sudden death. Longer QRS duration was observed with quadripolar leads (147 ± 23 vs 143 ± 25; p < 0.001). Outcome event rate for 100 patient years revealed no difference in HF hospitalization rates between bipolar and quadripolar LV leads. Quadripolar lead implant led to lower cardiac mortality, with no influence on overall mortality. Multivariate analysis revealed no significant differences in study endpoints between bipolar and quadripolar LV leads. CONCLUSION In a large real-life registry, implantation of quadripolar LV leads in patients with CRT-D did not influence HF hospitalization rates.
Collapse
Affiliation(s)
- Eran Leshem
- Department of Cardiology, Tel-Aviv Medical Center, Tel Aviv, Israel. .,Cardiovascular Institute, Beth Israel Deaconess Medical Center, 185 Pilgrim Rd, Boston, MA, 02215, USA.
| | | | | | - Moti Haim
- Cardiology Department, Soroka Medical Center, Beer Sheva, Israel
| | - Michael Geist
- Cardiology Department, Edith Wolfson Medical Center, Holon, Israel
| | - David Luria
- Cardiology Department, Hadassah Hebrew University Medical Center, Jerusalem, Israel
| | - Michael Glikson
- Leviev Heart Center, Sheba Medical Center, Tel Hashomer, Israel
| | - Ilan Goldenberg
- Leviev Heart Center, Sheba Medical Center, Tel Hashomer, Israel.,IACT-Neufeld Cardiac Research Institute, Tel Hashomer, Israel
| | - Yoav Michowitz
- Department of Cardiology, Tel-Aviv Medical Center, Tel Aviv, Israel
| | | |
Collapse
|
56
|
Wang J, Nie Z, Chen H, Shu X, Yang Z, Yao R, Su Y, Ge J. Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing. J Vis Exp 2017. [PMID: 29286395 DOI: 10.3791/56439] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
It is now well recognized that heart failure (HF) patients with left bundle branch block (LBBB) derive substantial clinical benefits from cardiac resynchronization therapy (CRT), and LBBB has become one of the important predictors for CRT response. The conventional tachypacing-induced HF model has several major limitations, including absence of stable LBBB and rapid reversal of left ventricular (LV) dysfunction after cessation of pacing. Hence, it is essential to establish an optimal model of chronic HF with isolated LBBB for studying CRT benefits. In the present study, a canine model of asynchronous HF induced by left bundle branch (LBB) ablation and 4 weeks of rapid right ventricular (RV) pacing is established. The RV and right atrial (RA) pacing electrodes via the jugular vein approach, together with an epicardial LV pacing electrode, were implanted for CRT performance. Presented here are the detailed protocols of radiofrequency (RF) catheter ablation, pacing leads implantation, and rapid pacing strategy. Intracardiac and surface electrograms during operation were also provided for a better understanding of LBB ablation. Two-dimensional speckle tracking imaging and aortic velocity time integral (aVTI) were acquired to validate the chronic stable HF model with LV asynchrony and CRT benefits. By coordinating ventricular activation and contraction, CRT uniformed the LV mechanical work and restored LV pump function, which was followed by reversal of LV dilation. Moreover, the histopathological study revealed a significant restoration of cardiomyocyte diameter and collagen volume fraction (CVF) after CRT performance, indicating a histologic and cellular reverse remodeling elicited by CRT. In this report, we described a feasible and valid method to develop a chronic asynchronous HF model, which was suitable for studying structural and biologic reverse remodeling following CRT.
Collapse
Affiliation(s)
- Jingfeng Wang
- Department of Cardiology, Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital, Fudan University
| | - Zhenning Nie
- Department of Cardiology, Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital, Fudan University
| | - Haiyan Chen
- Department of Echocardiography, Shanghai Institute of Medical imaging, Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital, Fudan University
| | - Xianhong Shu
- Department of Echocardiography, Shanghai Institute of Medical imaging, Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital, Fudan University
| | - Zhaohua Yang
- Department of Cardiac surgery, Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital, Fudan University
| | - Ruiming Yao
- Department of Cardiology, Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital, Fudan University
| | - Yangang Su
- Department of Cardiology, Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital, Fudan University;
| | - Junbo Ge
- Department of Cardiology, Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital, Fudan University
| |
Collapse
|
57
|
Manolis AS, Koulouris S, Tsiachris D. Electrophysiology Catheter-Facilitated coronary sinus cannulation and implantation of cardiac resynchronization therapy systems. Hellenic J Cardiol 2017; 59:26-33. [PMID: 28778735 DOI: 10.1016/j.hjc.2017.07.008] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2017] [Revised: 07/20/2017] [Accepted: 07/21/2017] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND Cardiac resynchronization therapy (CRT) device implantation is hampered by difficult placement of the left ventricular (LV) lead. We have routinely used a steerable electrophysiology catheter to guide coronary sinus (CS) cannulation and facilitate LV lead positioning. The aim of this prospective study is to present our results with this approach in 138 consecutive patients receiving a CRT device over 10 years. METHODS The study included 120 men and 18 women, aged 64.8±11.4 years, with coronary disease (n=63), cardiomyopathy (n=72), or other disease (n=3), and mean ejection fraction of 24.5±4.5%. Devices were implanted for refractory heart failure and dyssynchrony, all but 2 in the presence of left bundle branch block. Implanted devices included biventricular pacemakers (CRT-P) (n=33) and cardioverter defibrillators (CRT-D) (n=105). RESULTS Using the electrophysiology catheter, the CS could be engaged in 134 (97.1%) patients. In 4 patients failing CS cannulation, a dual-chamber device was implanted in 2, and bifocal right ventricular pacing was effected in 2. Bifocal (n=2) or conventional (n=1) systems were implanted in another 3 patients, in whom the LV lead got dislodged (n=2) or removed because of local dissection (n=1). Thus, finally, a CRT system was successfully established in 131 (94.9%) patients. There were 3 patients with CS dissection, of whom 1 was complicated by cardiac tamponade managed with pericardiocentesis. There were no perioperative deaths. During follow-up (31.0±21.2 months), clinical improvement was reported by 108 (82.4%) patients. CONCLUSION Routine use of an electrophysiology catheter greatly facilitated CS cannulation and successful LV lead placement in ∼95% of patients undergoing CRT system implantation.
Collapse
Affiliation(s)
- Antonis S Manolis
- Third Department of Cardiology, Athens University School of Medicine, Athens, Greece.
| | | | | |
Collapse
|
58
|
Sassone B, Bertini M, Beltrami M, Malagù M, Pasanisi G, Kuwornu HA, Avigni N, Fucà G, Pacchioni F, Minarelli M, Bacchi Reggiani ML, Padeletti L. Relation of QRS Duration to Response to Cardiac Resynchronization Therapy in Patients With Left Bundle Branch Block. Am J Cardiol 2017; 119:1803-1808. [PMID: 28391991 DOI: 10.1016/j.amjcard.2017.02.043] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/08/2016] [Revised: 02/17/2017] [Accepted: 02/17/2017] [Indexed: 11/16/2022]
Abstract
Left ventricular (LV) dyssynchrony (LVdys) is a necessary condition for successful cardiac resynchronization therapy (CRT). Despite left bundle branch block (LBBB) representing a reliable surrogate of LVdys, not all LBBB patients will respond to CRT. Our aim was to investigate the relation between QRS duration and LVdys in patients with LBBB who underwent CRT. We retrospectively studied 165 patients with LBBB who underwent CRT implantation according to the current guidelines. A 6-month reduction of LV end-systolic volume ≥15% identified responders to CRT. Baseline LVdys was defined as the delay between peak systolic velocities of the interventricular septum and lateral wall assessed by color-coded tissue Doppler imaging. Baseline characteristics of responders (61%) and nonresponders (39%) were comparable except for larger QRS complex (172 ± 24 vs 160 ± 16 ms, p <0.001) and lower degree of LVdys (46 ± 42 vs 72 ± 31 ms, p <0.001) in nonresponders. Receiver-operating characteristic curve analysis demonstrated that an optimal cut-off value of 3 for the ratio of QRS duration and LVdys (QRS/LVdys) yielded a sensitivity of 66% and specificity of 80% to predict nonresponsiveness to CRT; QRS/LVdys >3 remained an independent predictor at multivariate analysis. In patients with nonischemic origin of cardiomyopathy, the linear regression analysis documented a significant inverse relation between QRS duration and LVdys, as dyssynchrony progressively decreased as QRS widening increased (p = 0.006). This was not evident in patients with ischemic origin. In conclusion, in LBBB patients with nonischemic origin and marked QRS widening, the absence of LVdys may account for a lower response to CRT compared with patients with intermediate QRS widening.
Collapse
Affiliation(s)
- Biagio Sassone
- Department of Cardiology, SS.ma Annunziata Hospital, Azienda Unità Sanitaria Locale Ferrara, Cento, Ferrara, Italy; Department of Cardiology, Delta Hospital, Azienda Unità Sanitaria Locale Ferrara, Lagosanto, Ferrara, Italy.
| | - Matteo Bertini
- Department of Cardiology, S. Anna Hospital, University of Ferrara, Cona, Ferrara, Italy
| | - Matteo Beltrami
- Careggi Hospital, Institute of Internal Medicine and Cardiology, University of Florence, Florence, Italy
| | - Michele Malagù
- Department of Cardiology, S. Anna Hospital, University of Ferrara, Cona, Ferrara, Italy
| | - Giovanni Pasanisi
- Department of Cardiology, Delta Hospital, Azienda Unità Sanitaria Locale Ferrara, Lagosanto, Ferrara, Italy
| | - Helene Afi Kuwornu
- Department of Cardiology, Delta Hospital, Azienda Unità Sanitaria Locale Ferrara, Lagosanto, Ferrara, Italy
| | - Nicola Avigni
- Department of Cardiology, Delta Hospital, Azienda Unità Sanitaria Locale Ferrara, Lagosanto, Ferrara, Italy
| | - Giuseppe Fucà
- Department of Cardiology, SS.ma Annunziata Hospital, Azienda Unità Sanitaria Locale Ferrara, Cento, Ferrara, Italy
| | - Federico Pacchioni
- Department of Cardiology, SS.ma Annunziata Hospital, Azienda Unità Sanitaria Locale Ferrara, Cento, Ferrara, Italy
| | - Monica Minarelli
- Department of Cardiology, SS.ma Annunziata Hospital, Azienda Unità Sanitaria Locale Ferrara, Cento, Ferrara, Italy
| | | | - Luigi Padeletti
- Careggi Hospital, Institute of Internal Medicine and Cardiology, University of Florence, Florence, Italy; IRCCS Multimedica, Milan, Italy
| |
Collapse
|
59
|
Hernández-Madrid A, Facchin D, Klepfer RN, Ghosh S, Matía R, Moreno J, Locatelli A. Device pacing diagnostics overestimate effective cardiac resynchronization therapy pacing results of the hOLter for Efficacy analysis of CRT (OLÉ CRT) study. Heart Rhythm 2017; 14:541-547. [PMID: 28104482 DOI: 10.1016/j.hrthm.2017.01.022] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/17/2016] [Indexed: 10/20/2022]
Abstract
BACKGROUND A high percentage of biventricular (BiV) or left ventricular (LV) pacing in cardiac resynchronization therapy (CRT) devices has been associated with superior clinical outcomes. However, the percent ventricular (%V) pacing reported by CRT devices simply indicates the number of paces the device has delivered and not the proportion of pacing that has captured the LV effectively. OBJECTIVE The purpose of this study was to determine whether a beat-by-beat evaluation of effective pacing would provide a more accurate evaluation of CRT delivery. METHODS An automatic electrogram (EGM)-based algorithm that classifies each LV pace as effective or ineffective based on detection of QS/QS-r morphology on the unipolar LV EGM during pacing was developed and validated. LV EGMs that were recorded by 24-hour Holter from 57 CRT patients were postprocessed. The percent effective CRT (%e-CRT) pacing was calculated by dividing the time spent in e-CRT pacing by the total time of the recording. RESULTS In this CRT cohort, the average %V pacing (94.8% ± 8%) significantly overestimated the %e-CRT pacing (87.5% ± 23%; P <.001). A significant minority of subjects (18%) had a discrepancy of at least 3 percentage points between %V pacing and %e-CRT pacing (mean 39% ± 41%). CONCLUSION Current device pacing diagnostics overestimate the amount of CRT pacing actually delivered. The new algorithm quantifies ineffective CRT pacing, which enables clinicians to identify patients with this issue and to address the reasons behind suboptimal CRT delivery.
Collapse
Affiliation(s)
- Antonio Hernández-Madrid
- Arrhythmia Unit, Cardiology Department, Ramón y Cajal Hospital, Alcalá University, Madrid, Spain.
| | - Domenico Facchin
- Division of Cardiology, Cardiothoracic Department, University Hospital Santa Maria della Misericordia, Udine, Italy
| | | | - Subham Ghosh
- Medtronic PLC, Cardiac Rhythm and Heart Failure Research, Minneapolis, Minnesota
| | - Roberto Matía
- Arrhythmia Unit, Cardiology Department, Ramón y Cajal Hospital, Alcalá University, Madrid, Spain
| | - Javier Moreno
- Arrhythmia Unit, Cardiology Department, Ramón y Cajal Hospital, Alcalá University, Madrid, Spain
| | - Alessandro Locatelli
- Coronary Unit Department, Cardiology and Electrophysiology, ASST Bergamo Est, Ospedale Bolognini, Seriate, Italy
| |
Collapse
|
60
|
Boriani G. How to RESPOND to the quest to increase the effectiveness of cardiac resynchronization therapy? Eur Heart J 2016; 38:739-741. [DOI: 10.1093/eurheartj/ehw595] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|