51
|
Rana S. Intensity modulated radiation therapy versus volumetric intensity modulated arc therapy. J Med Radiat Sci 2013; 60:81-3. [PMID: 26229614 PMCID: PMC4175813 DOI: 10.1002/jmrs.19] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Affiliation(s)
- Suresh Rana
- Department of Medical Physics, ProCure Proton Therapy Center Oklahoma City, Oklahoma, USA
| |
Collapse
|
52
|
Elith CA, Dempsey SE, Warren-Forward HM. A retrospective planning analysis comparing intensity modulated radiation therapy (IMRT) to volumetric modulated arc therapy (VMAT) using two optimization algorithms for the treatment of early-stage prostate cancer. J Med Radiat Sci 2013; 60:84-92. [PMID: 26229615 PMCID: PMC4175809 DOI: 10.1002/jmrs.22] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2013] [Revised: 07/20/2013] [Accepted: 07/22/2013] [Indexed: 01/21/2023] Open
Abstract
INTRODUCTION The primary aim of this study is to compare intensity modulated radiation therapy (IMRT) to volumetric modulated arc therapy (VMAT) for the radical treatment of prostate cancer using version 10.0 (v10.0) of Varian Medical Systems, RapidArc radiation oncology system. Particular focus was placed on plan quality and the implications on departmental resources. The secondary objective was to compare the results in v10.0 to the preceding version 8.6 (v8.6). METHODS Twenty prostate cancer cases were retrospectively planned using v10.0 of Varian's Eclipse and RapidArc software. Three planning techniques were performed: a 5-field IMRT, VMAT using one arc (VMAT-1A), and VMAT with two arcs (VMAT-2A). Plan quality was assessed by examining homogeneity, conformity, the number of monitor units (MUs) utilized, and dose to the organs at risk (OAR). Resource implications were assessed by examining planning and treatment times. The results obtained using v10.0 were also compared to those previously reported by our group for v8.6. RESULTS In v10.0, each technique was able to produce a dose distribution that achieved the departmental planning guidelines. The IMRT plans were produced faster than VMAT plans and displayed improved homogeneity. The VMAT plans provided better conformity to the target volume, improved dose to the OAR, and required fewer MUs. Treatments using VMAT-1A were significantly faster than both IMRT and VMAT-2A. Comparison between versions 8.6 and 10.0 revealed that in the newer version, VMAT planning was significantly faster and the quality of the VMAT dose distributions produced were of a better quality. CONCLUSION VMAT (v10.0) using one or two arcs provides an acceptable alternative to IMRT for the treatment of prostate cancer. VMAT-1A has the greatest impact on reducing treatment time.
Collapse
Affiliation(s)
- Craig A Elith
- British Columbia Cancer Agency, Fraser Valley Centre Surrey, BC, Canada ; School of Health Sciences, University of Newcastle Newcastle, NSW, Australia
| | - Shane E Dempsey
- School of Health Sciences, University of Newcastle Newcastle, NSW, Australia
| | | |
Collapse
|
53
|
Ishii K, Ogino R, Okada W, Nakahara R, Kawamorita R, Nakajima T. A dosimetric comparison of RapidArc and IMRT with hypofractionated simultaneous integrated boost to the prostate for treatment of prostate cancer. Br J Radiol 2013; 86:20130199. [PMID: 23995872 DOI: 10.1259/bjr.20130199] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE To compare the dosimetric results and treatment delivery efficiency among RapidArc® (Varian Medical Systems, Palo Alto, CA), 7-field intensity-modulated radiotherapy (7-f IMRT) and 9-field IMRT (9-f IMRT) with hypofractionated simultaneous integrated boost to the prostate. METHODS RapidArc, 7-f IMRT and 9-f IMRT plans were created for 21 consecutive patients treated for high-risk prostate cancer using the Eclipse™ treatment planning system (Varian Medical Systems). All plans were designed to deliver 70.0 Gy in 28 fractions to the prostate planning target volume (PTV) while simultaneously delivering 50.4 Gy in 28 fractions to the pelvic nodal PTV. Target coverage and sparing of organs at risk (OARs) were compared across techniques. The total number of monitor units (MUs) and the treatment time were used to assess treatment delivery efficiency. RESULTS RapidArc resulted in slightly superior conformity and homogeneity of prostate PTV, whereas all plans were comparable with respect to dose to the nodal PTV. Although OARs sparing for RapidArc and 7-f IMRT plans were almost equivalent, 9-f IMRT achieved better sparing of the rectum and bladder than RapidArc and 7-f IMRT. RapidArc provided the highest treatment delivery efficiency with the lowest MUs and shortest treatment time. CONCLUSION RapidArc resulted in similar OAR sparing to 7-f IMRT, whereas 9-f IMRT provided the best OAR sparing. Treatment delivery efficiency is significantly higher for RapidArc. ADVANCES IN KNOWLEDGE This study validated the feasibility and limitations of RapidArc in the treatment of high-risk prostate cancer with complex pelvic target volumes.
Collapse
Affiliation(s)
- K Ishii
- Department of Radiation Oncology, Tane General Hospital, Osaka, Japan.
| | | | | | | | | | | |
Collapse
|
54
|
Tree A, Alexander E, Van As N, Dearnaley D, Khoo V. Biological Dose Escalation and Hypofractionation: What is There to be Gained and How Will it Best be Done? Clin Oncol (R Coll Radiol) 2013; 25:483-98. [DOI: 10.1016/j.clon.2013.05.003] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2013] [Accepted: 05/09/2013] [Indexed: 12/12/2022]
|
55
|
Ashamalla H, Tejwani A, Parameritis I, Swamy U, Luo PC, Guirguis A, Lavaf A. Comparison study of intensity modulated arc therapy using single or multiple arcs to intensity modulated radiation therapy for high-risk prostate cancer. Radiat Oncol J 2013; 31:104-10. [PMID: 23865007 PMCID: PMC3712173 DOI: 10.3857/roj.2013.31.2.104] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2013] [Revised: 06/06/2013] [Accepted: 06/10/2013] [Indexed: 12/25/2022] Open
Abstract
Purpose Intensity modulated arc therapy (IMAT) is a form of intensity modulated radiation therapy (IMRT) that delivers dose in single or multiple arcs. We compared IMRT plans versus single-arc field (1ARC) and multi-arc fields (3ARC) IMAT plans in high-risk prostate cancer. Materials and Methods Sixteen patients were studied. Prostate (PTVP), right pelvic (PTVRtLN) and left pelvic lymph nodes (PTVLtLN), and organs at risk were contoured. PTVP, PTVRtLN, and PTVLtLN received 50.40 Gy followed by a boost to PTVB of 28.80 Gy. Three plans were per patient generated: IMRT, 1ARC, and 3ARC. We recorded the dose to the PTV, the mean dose (DMEAN) to the organs at risk, and volume covered by the 50% isodose. Efficiency was evaluated by monitor units (MU) and beam on time (BOT). Conformity index (CI), Paddick gradient index, and homogeneity index (HI) were also calculated. Results Average Radiation Therapy Oncology Group CI was 1.17, 1.20, and 1.15 for IMRT, 1ARC, and 3ARC, respectively. The plans' HI were within 1% of each other. The DMEAN of bladder was within 2% of each other. The rectum DMEAN in IMRT plans was 10% lower dose than the arc plans (p < 0.0001). The GI of the 3ARC was superior to IMRT by 27.4% (p = 0.006). The average MU was highest in the IMRT plans (1686) versus 1ARC (575) versus 3ARC (1079). The average BOT was 6 minutes for IMRT compared to 1.3 and 2.9 for 1ARC and 3ARC IMAT (p < 0.05). Conclusion For high-risk prostate cancer, IMAT may offer a favorable dose gradient profile, conformity, MU and BOT compared to IMRT.
Collapse
Affiliation(s)
- Hani Ashamalla
- New York Methodist Hospital, Brooklyn, NY, USA. ; Leading Edge Radiation Oncology (LEROS), Weill Medical College of Cornell University, Brooklyn, NY, USA
| | | | | | | | | | | | | |
Collapse
|
56
|
Developments in External Beam Radiotherapy for Prostate Cancer. Urology 2013; 82:5-10. [DOI: 10.1016/j.urology.2013.03.043] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2013] [Revised: 02/14/2013] [Accepted: 03/23/2013] [Indexed: 11/17/2022]
|
57
|
Werbrouck J, Ost P, Fonteyne V, De Meerleer G, De Neve W, Bogaert E, Beels L, Bacher K, Vral A, Thierens H. Early biomarkers related to secondary primary cancer risk in radiotherapy treated prostate cancer patients: IMRT versus IMAT. Radiother Oncol 2013; 107:377-81. [PMID: 23791364 DOI: 10.1016/j.radonc.2013.05.014] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2013] [Revised: 05/03/2013] [Accepted: 05/06/2013] [Indexed: 02/02/2023]
Abstract
PURPOSE To investigate whether rotational techniques (Volumetric Modulated Arc Therapy - VMAT) are associated with a higher risk for secondary primary malignancies compared to step-and-shoot Intensity Modulated Radiation Therapy (ss-IMRT). To this end, radiation therapy (RT) induced DNA double-strand-breaks and the resulting chromosomal damage were assessed in peripheral blood T-lymphocytes of prostate cancer (PCa) patients applying γH2AX foci and G0 micronucleus (MN) assays. METHODS AND MATERIALS The study comprised 33PCa patients. A blood sample was taken before start of therapy and after the 1st and 3rd RT fraction to determine respectively the RT-induced γH2AX foci and MN. The equivalent total body dose (D(ETB)) was calculated based on treatment planning data. RESULTS A linear dose response was obtained for γH2AX foci yields versus D(ETB) while MN showed a linear-quadratic dose response. Patients treated with large volume (LV) VMAT show a significantly higher level of induced γH2AX foci and MN compared to IMRT and small volume (SV) VMAT (p<0.01). Assuming a linear-quadratic relationship, a satisfactory correlation was found between both endpoints (R(2) 0.86). CONCLUSIONS Biomarker responses were governed by dose and irradiated volume of normal tissues. No significant differences between IMRT and rotational therapy inherent to the technique itself were observed.
Collapse
Affiliation(s)
- Joke Werbrouck
- Department of Basic Medical Sciences, Ghent University, Gent, Belgium
| | | | | | | | | | | | | | | | | | | |
Collapse
|
58
|
A Retrospective Planning Analysis Comparing Volumetric-Modulated Arc Therapy (VMAT) to Intensity-Modulated Radiation Therapy (IMRT) for Radiotherapy Treatment of Prostate Cancer. J Med Imaging Radiat Sci 2013; 44:79-86. [DOI: 10.1016/j.jmir.2012.06.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2012] [Revised: 06/21/2012] [Accepted: 06/21/2012] [Indexed: 11/20/2022]
|
59
|
Clemente S, Cozzolino M, Chiumento C, Fiorentino A, Caivano R, Fusco V. Monitor unit optimization in RapidArc plans for prostate cancer. J Appl Clin Med Phys 2013; 14:4114. [PMID: 23652245 PMCID: PMC5714413 DOI: 10.1120/jacmp.v14i3.4114] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2012] [Revised: 11/02/2012] [Accepted: 12/11/2012] [Indexed: 11/23/2022] Open
Abstract
Intensity‐modulated radiation therapy (IMRT) has become a standard treatment for prostate cancer based on the superior sparing of the bladder, rectum, and other surrounding normal tissues compared to three‐dimensional conformal radiotherapy, despite the longer delivery time and the increased number of monitor units (MU). The novel RapidArc technique represents a further step forward because of the lower number of MUs per fraction and the shorter delivery time, compared to IMRT. This paper refers to MU optimization in RA plans for prostate cancer, using a tool incorporated in Varian TPS Eclipse. The goal was to get the lowest MU RA plan for each patient, keeping a well‐defined level of PTV coverage and OAR sparing. Seven prostate RA plans (RA MU‐Optimized) were retrospectively generated using the MU optimization tool in Varian Eclipse TPS. Dosimetric outcome and nontarget tissue sparing were compared to those of RA clinical plans (RA Clinical) used to treat patients. Compared to RA Clinical, RA MU‐Optimized plans resulted in an about 28% (p=0.018) reduction in MU. The total integral dose (ID) to each nontarget tissue (but not the penile bulb) showed a consistent average relative reduction, statistically significant only for the femoral heads. Within the intermediate dose region (40–60 Gy), ID reductions (4%−17% p<0.05) were found for the rectum, while a slight but significant (0.4%−0.9%,p<0.05) higher ID was found for the whole body. Among the remaining data, the mean dose to the bladder was also reduced (−12%,p=0.028). Plans using MU optimization are clinically applicable and more MU efficient, ameliorating the exposure of the rectum and the bladder to intermediate doses. PACS number: 87
Collapse
|
60
|
Pommer T, Falk M, Poulsen PR, Keall PJ, O'Brien RT, Petersen PM, Munck af Rosenschöld P. Dosimetric benefit of DMLC tracking for conventional and sub-volume boosted prostate intensity-modulated arc radiotherapy. Phys Med Biol 2013; 58:2349-61. [PMID: 23492899 DOI: 10.1088/0031-9155/58/7/2349] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
This study investigated the dosimetric impact of uncompensated motion and motion compensation with dynamic multileaf collimator (DMLC) tracking for prostate intensity modulated arc therapy. Two treatment approaches were investigated; a conventional approach with a uniform radiation dose to the target volume and an intraprostatic lesion (IPL) boosted approach with an increased dose to a subvolume of the prostate. The impact on plan quality of optimizations with a leaf position constraint, which limited the distance between neighbouring adjacent MLC leaves, was also investigated. Deliveries were done with and without DMLC tracking on a linear acceleration with a high-resolution MLC. A cylindrical phantom containing two orthogonal diode arrays was used for dosimetry. A motion platform reproduced six patient-derived prostate motion traces, with the average displacement ranging from 1.0 to 8.9 mm during the first 75 s. A research DMLC tracking system was used for real-time motion compensation with optical monitoring for position input. The gamma index was used for evaluation, with measurements with a static phantom or the planned dose as reference, using 2% and 2 mm gamma criteria. The average pass rate with DMLC tracking was 99.9% (range 98.7-100%, measurement as reference), whereas the pass rate for untracked deliveries decreased distinctly as the average displacement increased, with an average pass rate of 61.3% (range 32.7-99.3%). Dose-volume histograms showed that DMLC tracking maintained the planned dose distributions in the presence of motion whereas traces with >3 mm average displacement caused clear plan degradation for untracked deliveries. The dose to the rectum and bladder had an evident dependence on the motion direction and amplitude for untracked deliveries, and the dose to the rectum was slightly increased for IPL boosted plans compared to conventional plans for anterior motion with large amplitude. In conclusion, optimization using a leaf position constraint had minimal dosimetric effect, DMLC tracking improved the target and normal tissue dose distributions compared to no tracking for target motion >3 mm, with the DMLC tracking distributions showing generally good agreement between the planned and delivered doses.
Collapse
Affiliation(s)
- Tobias Pommer
- Radiation Medicine Research Center, Department of Radiation Oncology, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark.
| | | | | | | | | | | | | |
Collapse
|
61
|
Hall WA, Colbert L, Nickleach D, Shelton J, Marcus DM, Switchenko J, Rossi PJ, Godette K, Cooper S, Jani AB. Reduced acute toxicity associated with the use of volumetric modulated arc therapy for the treatment of adenocarcinoma of the prostate. Pract Radiat Oncol 2013; 3:e157-64. [PMID: 24674413 PMCID: PMC10388692 DOI: 10.1016/j.prro.2013.01.003] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2012] [Revised: 01/09/2013] [Accepted: 01/10/2013] [Indexed: 12/01/2022]
Abstract
PURPOSE Novel techniques to deliver intensity modulated radiation therapy (IMRT) have resulted in improved treatment efficiency and dosimetric endpoints. We aimed to compare acute gastrointestinal (GI) and genitourinary (GU) toxicity in patients treated for adenocarcinoma of the prostate (ACP) using volumetric modulated arc therapy (VMAT). METHODS AND MATERIALS A total of 122 (71 IMRT and 51 VMAT) ACP patients treated from 2004 to 2011 with definitive external beam radiation therapy were analyzed. Dose-volume histogram endpoints (V40, V65, V70, and V75 of the bladder and rectum) were collected for each patient. Median follow-up for patients treated with VMAT was 269 days versus IMRT was 1121 days. Acute Common Toxicity Criteria for Adverse Events (CTCAE) GI and GU toxicity scores, obtained during each weekly treatment check, were compared across cohorts. The univariate (UV) association between the covariates and outcomes was assessed and multivariable (MV) cumulative logit models were fit for each outcome. RESULTS Median patient age was 68 years and median prostate-specific antigen was 8.3. Both bladder and rectal V40, V65, V70, and V75 were all higher in the IMRT group versus the VMAT group (P < .05), which was likely influenced by larger planning target volumes in the IMRT group. The VMAT group had significantly lower rates of acute GU and acute GI CTCAE toxicity on UV association analysis. On MV analysis, VMAT remained independently associated with acute GU (odds ratio [OR], 0.18; 95% confidence interval [CI], 0.07-0.44; P < .001) and GI (OR, 0.16; 95% CI, 0.07-0.41; P < .001) toxicity. CONCLUSIONS VMAT appears to be independently associated with lower rates of acute GI and GU toxicity when compared with traditional IMRT. Further exploration of toxicity improvements associated with VMAT use in the definitive treatment of ACP is needed.
Collapse
Affiliation(s)
- William A Hall
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia.
| | - Lauren Colbert
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia
| | - Dana Nickleach
- Biostatistics & Bioinformatics Shared Resource at Winship Cancer Institute, Atlanta, Georgia
| | - Joseph Shelton
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia
| | - David M Marcus
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia
| | - Jeffrey Switchenko
- Biostatistics & Bioinformatics Shared Resource at Winship Cancer Institute, Atlanta, Georgia
| | - Peter J Rossi
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia
| | - Karen Godette
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia
| | - Sherrie Cooper
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia
| | - Ashesh B Jani
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia
| |
Collapse
|
62
|
Zhai DY, Yin Y, Gong GZ, Liu TH, Chen JH, Ma CS, Lu J. RapidArc radiotherapy for whole pelvic lymph node in cervical cancer with 6 and 15 MV: a treatment planning comparison with fixed field IMRT. JOURNAL OF RADIATION RESEARCH 2013; 54:166-73. [PMID: 23283869 PMCID: PMC3534268 DOI: 10.1093/jrr/rrs066] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/28/2012] [Revised: 07/08/2012] [Accepted: 07/09/2012] [Indexed: 06/01/2023]
Abstract
Dosimetric differences were investigated among single and dual arc RapidArc and fixed-field intensity-modulated radiotherapy (f-IMRT) treatment plans for whole pelvic irradiation of lymph nodes. A total of 12 patients who had undergone radical surgery for cervical cancer and who had demonstrated multiple pelvic lymph node metastases were treated with radiotherapy. For all 12 cases, 7-field IMRT, single-arc RapidArc and dual-arc RapidArc were applied with 6 MV and 15 MV X-ray energies. The radiation dosimetric parameters for the different plans were compared with one another. All the plans met the clinical requirements. The homogeneity, conformity and external volume indices of f-IMRT and dual-arc RapidArc were better than for single-arc RapidArc (P < 0.05), while the differences between f-IMRT and dual-arc RapidArc were not significant. There were no significant differences in the radiation dose to organs at risk, except for the small bowel receiving >40 Gy (f-IMRT and dual-arc < single-arc, P < 0.05). The differences in dose distributions between the two applied X-ray energies for each of the modality plans were not significant. RapidArc plans resulted in fewer monitor units than the corresponding f-IMRT plans. Also, there were no differences between the two photon energies, except for a reduction in the number of MUs for 15 MV (P > 0.05). Compared to f-IMRT, no significant dosimetric benefits were found using RapidArc for whole pelvic lymph node irradiation. However, RapidArc has been associated with shorter treatment time and fewer monitor units, supporting the case for its safety and efficacy for pelvic irradiation.
Collapse
Affiliation(s)
| | - Yong Yin
- Department of Radiation Physics, Shandong Cancer Hospital and Institute, 440 Jiyan Road, Jinan, Shandong Province 250117, China
| | | | | | | | | | | |
Collapse
|
63
|
Weber DC, Zilli T, Vallee JP, Rouzaud M, Miralbell R, Cozzi L. Intensity modulated proton and photon therapy for early prostate cancer with or without transperineal injection of a polyethylen glycol spacer: a treatment planning comparison study. Int J Radiat Oncol Biol Phys 2012; 84:e311-8. [PMID: 22999271 DOI: 10.1016/j.ijrobp.2012.03.028] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2011] [Revised: 03/07/2012] [Accepted: 03/08/2012] [Indexed: 12/13/2022]
Abstract
PURPOSE Rectal toxicity is a serious adverse effect in early-stage prostate cancer patients treated with curative radiation therapy (RT). Injecting a spacer between Denonvilliers' fascia increases the distance between the prostate and the anterior rectal wall and may thus decrease the rectal radiation-induced toxicity. We assessed the dosimetric impact of this spacer with advanced delivery RT techniques, including intensity modulated RT (IMRT), volumetric modulated arc therapy (VMAT), and intensity modulated proton beam RT (IMPT). METHODS AND MATERIALS Eight prostate cancer patients were simulated for RT with or without spacer. Plans were computed for IMRT, VMAT, and IMPT using the Eclipse treatment planning system using both computed tomography spacer+ and spacer- data sets. Prostate ± seminal vesicle planning target volume [PTV] and organs at risk (OARs) dose-volume histograms were calculated. The results were analyzed using dose and volume metrics for comparative planning. RESULTS Regardless of the radiation technique, spacer injection decreased significantly the rectal dose in the 60- to 70-Gy range. Mean V(70 Gy) and V(60 Gy) with IMRT, VMAT, and IMPT planning were 5.3 ± 3.3%/13.9 ± 10.0%, 3.9 ± 3.2%/9.7 ± 5.7%, and 5.0 ± 3.5%/9.5 ± 4.7% after spacer injection. Before spacer administration, the corresponding values were 9.8 ± 5.4% (P=.012)/24.8 ± 7.8% (P=.012), 10.1 ± 3.0% (P=.002)/17.9 ± 3.9% (P=.003), and 9.7 ± 2.6% (P=.003)/14.7% ± 2.7% (P=.003). Importantly, spacer injection usually improved the PTV coverage for IMRT. With this technique, mean V(70.2 Gy) (P=.07) and V(74.1 Gy) (P=0.03) were 100 ± 0% to 99.8 ± 0.2% and 99.1 ± 1.2% to 95.8 ± 4.6% with and without Spacer, respectively. As a result of spacer injection, bladder doses were usually higher but not significantly so. Only IMPT managed to decrease the rectal dose after spacer injection for all dose levels, generally with no observed increase to the bladder dose. CONCLUSIONS Regardless of the radiation technique, a substantial decrease of rectal dose was observed after spacer injection for curative RT to the prostate.
Collapse
Affiliation(s)
- Damien C Weber
- Department of Radiation Oncology, Geneva University Hospital, Geneva, Switzerland.
| | | | | | | | | | | |
Collapse
|
64
|
Foroudi F, Wilson L, Bressel M, Haworth A, Hornby C, Pham D, Cramb J, Gill S, Tai KH, Kron T. A dosimetric comparison of 3D conformal vs intensity modulated vs volumetric arc radiation therapy for muscle invasive bladder cancer. Radiat Oncol 2012; 7:111. [PMID: 22824133 PMCID: PMC3444363 DOI: 10.1186/1748-717x-7-111] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2012] [Accepted: 07/03/2012] [Indexed: 11/25/2022] Open
Abstract
BACKGROUND To compare 3 Dimensional Conformal radiotherapy (3D-CRT) with Intensity Modulated Radiotherapy (IMRT) with Volumetric-Modulated Arc Therapy (VMAT) for bladder cancer. METHODS Radiotherapy plans for 15 patients with T2-T4N0M0 bladder cancer were prospectively developed for 3-DCRT, IMRT and VMAT using Varian Eclipse planning system. The same radiation therapist carried out all planning and the same clinical dosimetric constraints were used. 10 of the patients with well localised tumours had a simultaneous infield boost (SIB) of the primary tumour planned for both IMRT and VMAT. Tumour control probabilities and normal tissue complication probabilities were calculated. RESULTS Mean planning time for 3D-CRT, IMRT and VMAT was 30.0, 49.3, and 141.0 minutes respectively. The mean PTV conformity (CI) index for 3D-CRT was 1.32, for IMRT 1.05, and for VMAT 1.05. The PTV Homogeneity (HI) index was 0.080 for 3D-CRT, 0.073 for IMRT and 0.086 for VMAT. Tumour control and normal tissue complication probabilities were similar for 3D-CRT, IMRT and VMAT. The mean monitor units were 267 (range 250-293) for 3D-CRT; 824 (range 641-1083) for IMRT; and 403 (range 333-489) for VMAT (P < 0.05). Average treatment delivery time were 2:25min (range 2:01-3:09) for 3D-CRT; 4:39 (range 3:41-6:40) for IMRT; and 1:14 (range 1:13-1:14) for VMAT. In selected patients, the SIB did not result in a higher dose to small bowel or rectum. CONCLUSIONS VMAT is associated with similar dosimetric advantages as IMRT over 3D-CRT for muscle invasive bladder cancer. VMAT is associated with faster delivery times and less number of mean monitor units than IMRT. SIB is feasible in selected patients with localized tumours.
Collapse
Affiliation(s)
- Farshad Foroudi
- Division of Radiation Oncology, Peter MacCallum Cancer Center, Peter MacCallum Cancer Institute, St Andrews Place, East Melbourne, VIC, 3002, Australia
| | - Lesley Wilson
- Radiation Therapy Services, Peter MacCallum Cancer Center, Melbourne, VIC, Australia
| | - Mathias Bressel
- Biostatistics and Clinical Trials, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia
| | - Annette Haworth
- Physical Sciences, Peter MacCallum Cancer Center, Melbourne, VIC, Australia
| | - Colin Hornby
- Radiation Therapy Services, Peter MacCallum Cancer Center, Melbourne, VIC, Australia
| | - Daniel Pham
- Radiation Therapy Services, Peter MacCallum Cancer Center, Melbourne, VIC, Australia
| | - Jim Cramb
- Physical Sciences, Peter MacCallum Cancer Center, Melbourne, VIC, Australia
| | - Suki Gill
- Division of Radiation Oncology, Peter MacCallum Cancer Center, Peter MacCallum Cancer Institute, St Andrews Place, East Melbourne, VIC, 3002, Australia
| | - Keen Hun Tai
- Division of Radiation Oncology, Peter MacCallum Cancer Center, Peter MacCallum Cancer Institute, St Andrews Place, East Melbourne, VIC, 3002, Australia
| | - Tomas Kron
- Physical Sciences, Peter MacCallum Cancer Center, Melbourne, VIC, Australia
| |
Collapse
|
65
|
Sung W, Park JM, Choi CH, Ha SW, Ye SJ. The effect of photon energy on intensity-modulated radiation therapy (IMRT) plans for prostate cancer. Radiat Oncol J 2012; 30:27-35. [PMID: 23120741 PMCID: PMC3475960 DOI: 10.3857/roj.2012.30.1.27] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2012] [Revised: 03/05/2012] [Accepted: 03/09/2012] [Indexed: 01/10/2023] Open
Abstract
Purpose To evaluate the effect of common three photon energies (6-MV, 10-MV, and 15-MV) on intensity-modulated radiation therapy (IMRT) plans to treat prostate cancer patients. Materials and Methods Twenty patients with prostate cancer treated locally to 81.0 Gy were retrospectively studied. 6-MV, 10-MV, and 15-MV IMRT plans for each patient were generated using suitable planning objectives, dose constraints, and 8-field setting. The plans were analyzed in terms of dose-volume histogram for the target coverage, dose conformity, organs at risk (OAR) sparing, and normal tissue integral dose. Results Regardless of the energies chosen at the plans, the target coverage, conformity, and homogeneity of the plans were similar. However, there was a significant dose increase in rectal wall and femoral heads for 6-MV compared to those for 10-MV and 15-MV. The V20 Gy of rectal wall with 6-MV, 10-MV, and 15-MV were 95.6%, 88.4%, and 89.4% while the mean dose to femoral heads were 31.7, 25.9, and 26.3 Gy, respectively. Integral doses to the normal tissues in higher energy (10-MV and 15-MV) plans were reduced by about 7%. Overall, integral doses in mid and low dose regions in 6-MV plans were increased by up to 13%. Conclusion In this study, 10-MV prostate IMRT plans showed better OAR sparing and less integral doses than the 6-MV. The biological and clinical significance of this finding remains to be determined afterward, considering neutron dose contribution.
Collapse
Affiliation(s)
- Wonmo Sung
- Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul, Korea. ; Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea
| | | | | | | | | |
Collapse
|
66
|
Yoon WS, Yang DS, Lee JA, Lee S, Park YJ, Kim CY. The extent and serial pattern of interfractional variation in patients with whole pelvic irradiation: a study using a kilovoltage orthogonal on-board imager. J Appl Clin Med Phys 2012; 13:3636. [PMID: 22402382 PMCID: PMC5716416 DOI: 10.1120/jacmp.v13i2.3636] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2011] [Revised: 11/28/2011] [Accepted: 11/30/2011] [Indexed: 11/23/2022] Open
Abstract
The purpose of this study is to assess the extent and serial pattern of setup error of conventional fractionated whole pelvic irradiation using a kilovoltage on-board imager. The daily on-board images of 69 patients were matched with the digitally reconstructed radiographs of simulation on the basis of pelvic bony structure. The shifts along x- (lateral), y- (longitudinal), and z- (vertical) axes, and the 3D vector, were measured. The shift between an origin of the first fraction and each fraction (Δshift(1st)) and the shift between an isocenter of simulation and each fraction (Δshift(Sim)) were calculated. To evaluate serial changes, the shifts of each fraction were classified into four consecutive sessions, and an ANOVA and chi-square test were used. The systematic error of the Δshift(Sim) and Δshift(1st) were 2.72 and 1.43 mm along the x-axis, 2.98 and 1.28 mm along the y-axis, and 4.26 and 2.39 mm along the z-axis, respectively. The Δshift(Sim) and Δshift(1st) ≥ 5 mm of the 3D vector occurred in 54.3% and 23.1%, respectively. The recommended margins to cover setup error in case of using Δshift(1st) were 3.81, 3.54, and 6.01 mm along x-, y-, and z-axes, whereas those using Δshift(Sim) were 6.39, 6.95, and 9.95 mm, respectively. With the passage of time, the Δshift(1st) ≥ 5 mm of 3D vector and along any axis in supine setup increased from 14.1% for first session to 22.5% for fourth session (p=0.027) and from 10.8% to 18.5% (p = 0.034), respectively. In prone setup, first session was better than others in the Δshift(1st) ≥ 5 mm of 3D vector and along any axis. It is expected that the correction using the on-board images on the first fraction improves geometrical uncertainties and reduces the margin for target coverage. Daily continuous OBI follow-up during conventional fractionated pelvic irradiation can increase the reproducibility and be more effective in the late period.
Collapse
Affiliation(s)
- Won Sup Yoon
- Department of Radiation Oncology, Korea University College of Medicine, Seoul, Republic of Korea
| | | | | | | | | | | |
Collapse
|
67
|
Alexander EJ, Harris VA, Sohaib A, Dearnaley D. Reducing the side effects of external beam radiotherapy in prostate cancer: role of imaging techniques. ACTA ACUST UNITED AC 2012. [DOI: 10.2217/iim.11.65] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
68
|
Teoh M, Clark CH, Wood K, Whitaker S, Nisbet A. Volumetric modulated arc therapy: a review of current literature and clinical use in practice. Br J Radiol 2011; 84:967-96. [PMID: 22011829 DOI: 10.1259/bjr/22373346] [Citation(s) in RCA: 440] [Impact Index Per Article: 33.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
Volumetric modulated arc therapy (VMAT) is a novel radiation technique, which can achieve highly conformal dose distributions with improved target volume coverage and sparing of normal tissues compared with conventional radiotherapy techniques. VMAT also has the potential to offer additional advantages, such as reduced treatment delivery time compared with conventional static field intensity modulated radiotherapy (IMRT). The clinical worldwide use of VMAT is increasing significantly. Currently the majority of published data on VMAT are limited to planning and feasibility studies, although there is emerging clinical outcome data in several tumour sites. This article aims to discuss the current use of VMAT techniques in practice and review the available data from planning and clinical outcome studies in various tumour sites including prostate, pelvis (lower gastrointestinal, gynaecological), head and neck, thoracic, central nervous system, breast and other tumour sites.
Collapse
Affiliation(s)
- M Teoh
- Department of Oncology, St Luke's Cancer Centre, Royal Surrey County Hospital, Guildford, Surrey, UK.
| | | | | | | | | |
Collapse
|
69
|
Clinical results after high-dose intensity-modulated radiotherapy for high-risk prostate cancer. Adv Urol 2011; 2012:368528. [PMID: 22190918 PMCID: PMC3235425 DOI: 10.1155/2012/368528] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2011] [Accepted: 09/21/2011] [Indexed: 12/03/2022] Open
Abstract
Purpose. Patients with high-risk prostate cancer (PC) can be treated with high-dose intensity-modulated radiotherapy (IMRT) and long-term androgen deprivation (AD). In this paper we report on (i) late toxicity and (ii) biochemical (bRFS) and clinical relapse-free survival (cRFS) of this combined treatment. Methods. 126 patients with high-risk PC (T3-4 or PSA >20 ng/mL or Gleason 8–10) and ≥24 months of followup were treated with high-dose IMRT and AD. Late toxicity was recorded. Biochemical relapse was defined as PSA nadir +2 ng/mL. Clinical relapse was defined as local failure or metastases. Results. The incidence of late grade 3 gastrointestinal and genitourinary toxicity was 2 and 6%, respectively. Five-year bRFS and cRFS were 73% and 86% respectively. AD was a significant predictor of bRFS (P = 0.001) and cRFS (P = 0.01). Conclusion. High-dose IMRT and AD for high-risk PC offers excellent biochemical and clinical control with low toxicity.
Collapse
|
70
|
Pasler M, Georg D, Wirtz H, Lutterbach J. Effect of photon-beam energy on VMAT and IMRT treatment plan quality and dosimetric accuracy for advanced prostate cancer. Strahlenther Onkol 2011; 187:792-8. [PMID: 22127357 DOI: 10.1007/s00066-011-1150-0] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2011] [Accepted: 09/13/2011] [Indexed: 11/25/2022]
Abstract
PURPOSE The goal of the research was to evaluate treatment plan quality and dosimetric accuracy of volumetric modulated arc therapy (VMAT) and intensity-modulated radiotherapy (IMRT) plans using 6, 10, and 15 MV photon beams for prostate cancer including lymph nodes. METHODS In this retrospective study, VMAT and IMRT plans were generated with the Pinnacle© treatment planning system (TPS) (V9.0) for 10 prostate cancer cases. Each plan consisted of two target volumes: PTV(B) included the prostate bed, PTV(PC+LN) contained PTV(B) and lymph nodes. For plan evaluation statistics, the homogeneity index, conformity index, mean doses, and near-max doses to organs at risk (OAR) were analyzed. Treatment time and number of monitor units were assessed to compare delivery efficiency. Dosimetric plan verification was performed with a 2D ionization chamber array placed in a full scatter phantom. RESULTS No differences were found for target and OAR parameters in low and high energy photon beam plans for both VMAT and IMRT. A slightly higher low dose volume was detected for 6 MV VMAT plans (normal tissue: D(mean) = 16.47 Gy) compared to 10 and 15 MV VMAT plans (D(mean) = 15.90 Gy and 15.74 Gy, respectively), similar to the findings in IMRT. In VMAT, > 96% of detector points passed the 3%/ 3 mm γ criterion; marginally better accuracy was found in IMRT (> 97%). CONCLUSION For static and rotational IMRT, 15 MV photons did not show advantages over 6 and 10 MV high energy photon beams in large volume pelvic plans. For the investigated TPS and linac combination, 10 MV photon beams can be used as the general purpose energy for intensity modulation.
Collapse
Affiliation(s)
- Marlies Pasler
- Lake Constance Radiation Oncology Center Singen-Friedrichshafen, Singen, Germany
| | | | | | | |
Collapse
|
71
|
Georg D, Knöös T, McClean B. Current status and future perspective of flattening filter free photon beams. Med Phys 2011; 38:1280-93. [PMID: 21520840 DOI: 10.1118/1.3554643] [Citation(s) in RCA: 208] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Flattening filters (FFs) have been considered as an integral part of the treatment head of a medical accelerator for more than 50 years. The reasons for the longstanding use are, however, historical ones. Advanced treatment techniques, such as stereotactic radiotherapy or intensity modulated radiotherapy have stimulated the interest in operating linear accelerators in a flattening filter free (FFF) mode. The current manuscript reviews treatment head physics of FFF beams, describes their characteristics and the resulting potential advantages in their medical use, and closes with an outlook. METHODS A number of dosimetric benefits have been determined for FFF beams, which range from increased dose rate and dose per pulse to favorable output ratio in-air variation with field size, reduced energy variation across the beam, and reduced leakage and out-of-field dose, respectively. Finally, the softer photon spectrum of unflattened beams has implications on imaging strategies and radiation protection. RESULTS The dosimetric characteristics of FFF beams have an effect on treatment delivery, patient comfort, dose calculation accuracy, beam matching, absorbed dose determination, treatment planning, machine specific quality assurance, imaging, and radiation protection. When considering conventional C-arm linacs in a FFF mode, more studies are needed to specify and quantify the clinical advantages, especially with respect to treatment plan quality and quality assurance. CONCLUSIONS New treatment units are already on the market that operate without a FF or can be operated in a dedicated clinical FFF mode. Due to the convincing arguments of removing the FF, it is expected that more vendors will offer dedicated treatment units for advanced photon beam therapy in the near future. Several aspects related to standardization, dosimetry, treatment planning, and optimization need to be addressed in more detail in order to facilitate the clinical implementation of unflattened beams.
Collapse
Affiliation(s)
- Dietmar Georg
- Department of Radiotherapy, Division of Medical Radiation Physics, Medical University of Vienna/AKH Vienna, A-1090 Vienna, Austria.
| | | | | |
Collapse
|