51
|
Baillif S, Hartmann D, Freney J, Kodjikian L. [Intraocular lens and bacterial adhesion: influence of the environmental factors, the characteristics of the bacteria, and the target material surface]. J Fr Ophtalmol 2010; 33:210-21. [PMID: 20202716 DOI: 10.1016/j.jfo.2010.01.016] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2009] [Accepted: 12/22/2009] [Indexed: 10/19/2022]
Abstract
Adhesion of bacteria to intraocular lenses is an important step in the pathogenesis of postoperative endophthalmitis. It can be described as a two-phase process including an initial, instantaneous, and reversible phase followed by a time-dependant and irreversible molecular and cellular phase. The binding of bacteria is affected by many factors including environmental factors such as medium composition, presence of proteins and flow conditions, the bacterial cell surface characteristics, and the material's surface properties. This article reviews all these factors affecting the adhesion of bacteria to intraocular lenses. A better understanding of these mechanisms would make it possible to reduce the bacterial adhesion process and thus could help decrease the incidence of postoperative endophthalmitis.
Collapse
Affiliation(s)
- S Baillif
- Département d'Ophtalmologie, Centre hospitalo-universitaire Saint Roch, Nice, France; Laboratoire "Réparation Tissulaire, Interactions Biologiques et Biomatériaux", UPSP 2007.03.135 RTI2B, Lyon, France
| | | | | | | |
Collapse
|
52
|
Luensmann D, Heynen M, Liu L, Sheardown H, Jones L. Determination of albumin sorption to intraocular lenses by radiolabeling and confocal laser scanning microscopy. J Cataract Refract Surg 2010; 35:2000-7. [PMID: 19878835 DOI: 10.1016/j.jcrs.2009.05.052] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2009] [Revised: 05/22/2009] [Accepted: 05/26/2009] [Indexed: 11/24/2022]
Abstract
PURPOSE To determine albumin adsorption profiles and penetration depth of 3 intraocular lens (IOL) materials over time using confocal laser scanning microscopy (CLSM) and radiolabeling. SETTING Centre for Contact Lens Research, School of Optometry, and Department of Biology, University of Waterloo, Waterloo, Ontario, Canada. METHODS Poly(methyl methacrylate) (PMMA), silicone, and foldable hydrophilic acrylic IOLs were incubated in 0.5 mg/mL bovine serum albumin (BSA) for 1, 7, and 14 days. The BSA was conjugated with lucifer yellow VS to allow identification of the protein location by fluorescent imaging with CLSM. Next, the protein uptake was quantified using 2% (125)I-labeled BSA. RESULTS Confocal laser scanning microscopy showed increasing BSA uptake for silicone and PMMA IOLs after 14 days of incubation (P<.05), with an apparent penetration depth of 8.7 microm +/- 1.9 (SD) and 9.2 +/- 1.4 microm, respectively. For hydrophilic acrylic IOLs, BSA was detected at a depth of 38 +/- 7.4 microm after 1 day, followed by an increase to 192.7 +/- 16.2 microm after 14 days. Despite the penetration depth into the hydrophilic acrylic IOLs, quantitative results confirmed that PMMA and hydrophilic acrylic deposited significantly less BSA (mean 278.3 +/- 41.7 ng and 296.5 +/- 33.1 ng, respectively) than silicone IOLs (mean 392.6 +/- 37.6 ng) (P<.05). CONCLUSIONS Silicone and PMMA IOL materials showed BSA sorption near the lens surface only, while BSA penetrated deep into the hydrophilic acrylic IOL matrix. Combining the qualitative CLSM method and quantitative radiolabeling technique provided detailed information on protein interactions with implantable biomaterials.
Collapse
Affiliation(s)
- Doerte Luensmann
- Centre for Contact Lens Research, School of Optometry, University of Waterloo, Waterloo, Ontario, Canada.
| | | | | | | | | |
Collapse
|
53
|
Analysis of surface whitening of extracted hydrophobic acrylic intraocular lenses. J Cataract Refract Surg 2010; 35:1927-34. [PMID: 19878825 DOI: 10.1016/j.jcrs.2009.07.004] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2009] [Revised: 06/04/2009] [Accepted: 07/01/2009] [Indexed: 11/23/2022]
Abstract
PURPOSE To identify the cause of light scattering on the surface (ie, whitening) of extracted AcrySof intraocular lenses (IOLs). SETTING Department of Ophthalmology, Dokkyo Medical University, Tochigi, Japan. METHODS Dislocated IOLs extracted from 3 patients were stored and the IOL surfaces examined under light microscopy. The effect of whitening on visual function was evaluated by measuring light transmission with a spectrophotometer. To determine the cause of opacification, the IOLs were examined for calcium phosphate deposits using an electron probe X-ray microanalyzer. The IOL surface, including the presence of organic deposits and evidence of hydrolysis, was also examined by Fourier-transform infrared spectrophotometry. The IOLs were then dried, immersed again in physiological saline, and serially examined for changes in opacification. RESULTS The optic surfaces of all IOLs had opacification due to whitening. Light transmission in the visible range of 360 to 800 nm was 4% less than that of unused IOLs. The X-ray microanalysis showed no calcium phosphate deposits. Fourier-transform infrared spectrophotometry of the IOL optic material showed no evidence of hydrolysis. Opacification disappeared after the IOLs were dried and then reappeared over time when the IOL was immersed again in physiologic saline. CONCLUSIONS The findings strongly suggest that whitening of the hydrophobic acrylic IOL was due to trace water molecules that infiltrate the optic. Within the 3-dimensional network of the polymeric lens material, the molecules are too small to form observable voids but can form water aggregates of sufficient size to scatter visible light, causing opacification (ie, whitening).
Collapse
|
54
|
Rozema JJ, Koppen C, de Groot V, Tassignon MJ. Influence of neodymium:YAG laser capsulotomy on ocular wavefront aberrations in pseudophakic eyes with hydrophilic and hydrophobic intraocular lenses. J Cataract Refract Surg 2009; 35:1906-10. [DOI: 10.1016/j.jcrs.2009.06.033] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2009] [Revised: 06/02/2009] [Accepted: 06/05/2009] [Indexed: 11/12/2022]
|
55
|
Schroeder AC, Lingenfelder C, Seitz B, Grabowy U, W Spraul C, Gatzioufas Z, Herrmann M. Impact of fibronectin on surface properties of intraocular lenses. Graefes Arch Clin Exp Ophthalmol 2009; 247:1277-83. [PMID: 19578868 DOI: 10.1007/s00417-009-1130-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2009] [Accepted: 06/15/2009] [Indexed: 11/25/2022] Open
Abstract
PURPOSE Physical properties of intraocular lens (IOL) surfaces determine biocompatibility. IOL hydrophobicity of commercially available IOLs with and without fibronectin (FN) coating can be determined by surface contact angle (SCA) measurements. SCA data of IOLs may allow for a rational selection of an IOL type as a function of underlying eye disease. SETTING University Hospital of Saarland, Homburg (Saar), Germany METHODS Thirteen IOL types were tested. IOLs were made of poly(methyl methacrylate)(PMMA), acrylate, or silicone. Select IOLs were surface modified by the manufacturer with heparin or a polysaccharide coating. SCA values of IOLs, either uncoated or precoated with FN, were determined using the sessile water drop method. RESULTS SCA values ranged from 61.3 to 116.1 degrees for unmodified IOLs, with PMMA IOLs being more hydrophilic (median SCA, 74.1 degrees ), silicone IOLs more hydrophobic (median SCA, 113.3 degrees ), and acrylate IOLs intermediate (median SCA, 86.6 degrees ). Upon FN coating, all genuine acrylate lenses became significantly more hydrophilic while this effect was either nonsignificant or opposite on some PMMA and silicon IOLs. Heparin or polysaccharide surface modification resulted in significantly reduced SCA values. On acrylate IOLs, SCA values did not correlate with the aqueous content of the material. CONCLUSIONS This study associates IOL materials, surface modifications, and the role of FN preadsorption with SCA values reflecting surface hydrophobicity versus hydrophilicity. It provides a rationale for specific IOL selection as a function of the clinical setting, and a basis for IOL development using tailored surface physicochemistry to enhance biocompatibility and to reduce susceptibility to implant infection.
Collapse
Affiliation(s)
- Andreas C Schroeder
- Department of Ophthalmology, University of Saarland Hospital, 66421 Homburg, Saar, Germany.
| | | | | | | | | | | | | |
Collapse
|
56
|
Werner L. Secondary Cataract. Ophthalmology 2009. [DOI: 10.1016/b978-0-323-04332-8.00072-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
|
57
|
Werner L, Izak AM, Isaacs RT, Pandey SK, Apple DJ. Evolution of Intraocular Lens Implantation. Ophthalmology 2009. [DOI: 10.1016/b978-0-323-04332-8.00058-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
|
58
|
Gift BW, English RV, Nadelstein B, Weigt AK, Gilger BC. Comparison of capsular opacification and refractive status after placement of three different intraocular lens implants following phacoemulsification and aspiration of cataracts in dogs. Vet Ophthalmol 2009; 12:13-21. [DOI: 10.1111/j.1463-5224.2009.00667.x] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
59
|
Schroeder AC, Schmidbauer JM, Sobke A, Seitz B, Ruprecht KW, Herrmann M. Influence of fibronectin on the adherence of Staphylococcus epidermidis to coated and uncoated intraocular lenses. J Cataract Refract Surg 2008; 34:497-504. [PMID: 18299078 DOI: 10.1016/j.jcrs.2007.10.042] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2007] [Accepted: 10/25/2007] [Indexed: 11/25/2022]
Abstract
PURPOSE To determine the effect of the modification of intraocular lens (IOL) surface properties on the adhesion of Staphylococcus epidermidis caused by fibronectin (FN) as the predominant proadhesive glycoprotein of the eye's initial foreign body reaction. SETTING University of Saarland, Homburg/Saar, Germany. METHODS Eleven IOL types were tested. The IOLs were of poly(methyl methacrylate), acrylate, or silicone. Some were surface modified with heparin or polysaccharide coating. The IOLs, unadsorbed or preadsorbed with fibronectin (FN), were incubated with [(3)H]-thymidine-labeled S epidermidis Rp62a, and the amount of adherent microorganisms was determined. RESULTS Attachment of S epidermidis adhesion to various types of IOLs, both unadsorbed and FN precoated, varied significantly. The attachment to highly adhesive IOLs was almost 4-fold greater than that to low-adhesive IOLs. Attachment to FN precoated IOLs was generally enhanced compared with attachment to unadsorbed IOLs. Heparin surface modification resulted in no or a modest reduction in bacterial adhesion compared with unmodified IOLs. Bacterial adhesion was highly statistically significantly less on IOLs with polysaccharide surface modification. CONCLUSIONS There was significant variability in S epidermidis adhesion to IOLs as a function of design, material, surface modification, and FN preadsorption. Application of the findings may foster new developments to further reduce the major complication in cataract surgery, infective endophthalmitis.
Collapse
Affiliation(s)
- Andreas C Schroeder
- Department and Hospital of Ophthalmology, University of Saarland Hospital, Homburg/Saar, Germany.
| | | | | | | | | | | |
Collapse
|
60
|
Abstract
PURPOSE OF REVIEW To provide an update on currently available materials used in the manufacture of intraocular lenses, as well as new materials under development, especially with regard to their uveal and capsular biocompatibility. RECENT FINDINGS The biocompatibility of intraocular lens materials should be assessed in terms of uveal biocompatibility, related to the inflammatory foreign-body reaction of the eye against the implant, as well as in terms of capsular biocompatibility, determined by the relationship of the intraocular lens with remaining lens epithelial cells within the capsular bag. This situation may result in different entities, e.g. anterior capsule opacification, interlenticular opacification (between piggyback intraocular lenses), posterior capsule opacification and lens epithelial cell ongrowth. Reports on intraocular lens opacification suggest that the potential to calcify should also be taken into consideration when evaluating the long-term biocompatibility of a new material. SUMMARY Intraocular lenses are being progressively implanted in much earlier stages of life (refractive lens exchange, pediatric implantation) and are expected to remain in the intraocular environment for many decades. Materials used in intraocular lens manufacture should, therefore, insure long-term uveal and capsular biocompatibility, as well as ultimate transparency after implantation.
Collapse
|
61
|
Kim HY, Lee HI, Chun YS, Kim JC. The Effectiveness of Tranilast in the Prevention of Posterior Capsular Opacity. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2008. [DOI: 10.3341/jkos.2008.49.12.1981] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Affiliation(s)
- Ho Young Kim
- Department of Ophthalmology, Chung-Ang University College of Medicine, Seoul, Korea
| | | | - Yeoun Sook Chun
- Department of Ophthalmology, Chung-Ang University College of Medicine, Seoul, Korea
| | - Jae Chan Kim
- Department of Ophthalmology, Chung-Ang University College of Medicine, Seoul, Korea
| |
Collapse
|
62
|
Yaguchi S, Nishihara H, Kambhiranond W, Stanley D, Apple DJ. Light Scatter on the Surface of AcrySof® Intraocular Lenses: Part I. Analysis of Lenses Retrieved From Pseudophakic Postmortem Human Eyes. Ophthalmic Surg Lasers Imaging Retina 2008; 39:209-13. [DOI: 10.3928/15428877-20080501-22] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
63
|
Bhattacharjee H, Bhattacharjee K, Bhattacharjee P. Delayed accumulation of lens material behind the foldable intraocular lens. Indian J Ophthalmol 2007; 55:472-5. [PMID: 17951912 PMCID: PMC2636003 DOI: 10.4103/0301-4738.36490] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Foldable acrylic intraocular lenses (IOLs) are known to reduce posterior capsule opacification by preventing migration of lens epithelial cells with its square edge design and its property of tackiness. Studies have reported a mean adhesiveness to posterior capsule more than three times higher for certain acrylic foldable IOLs than polymethyl methacrylate IOLs. The authors would like to report two cases where the force of tackiness was compensated, thereby presenting with delayed accumulation of lens material in the capsular bags behind the IOL with temporary loss of vision.
Collapse
|
64
|
Abstract
The first lens implantations were performed by Sir Harold Ridley in 1949 using rigid poly-methyl-methacrylate (PMMA) lenses. This biomaterial was used exclusively for more than 30 years. In the early 1970s, Charles Kelman introduced phacoemulsification, reducing the incision size and beginning biomaterial diversification, including foldable materials. More than 50 years after the introduction of PMMA, the range of biomaterials used for intraocular lenses remains extremely limited. Among the materials tested, acrylic polymers and silicon elastomeres are the only remaining materials used for optics. In vivo tolerance is no longer the sole criterion in choosing biomaterials: clinical performance now plays a major role, including injection abilities, optical qualities, and long-term postoperative intraocular behavior. Together with lens design, the analysis of the physical and chemical characteristics of biomaterials will contribute to the choice of the best intraocular lens.
Collapse
|
65
|
Leydolt C, Davidovic S, Sacu S, Menapace R, Neumayer T, Prinz A, Buehl W, Findl O. Long-term Effect of 1-Piece and 3-Piece Hydrophobic Acrylic Intraocular Lens on Posterior Capsule Opacification. Ophthalmology 2007; 114:1663-9. [PMID: 17822973 DOI: 10.1016/j.ophtha.2006.12.016] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2006] [Revised: 12/11/2006] [Accepted: 12/11/2006] [Indexed: 10/22/2022] Open
Abstract
PURPOSE To compare the intensity of posterior capsule opacification (PCO) between the 1-piece and 3-piece haptic designs of the foldable hydrophobic acrylic AcrySof intraocular lens (IOL) over a 5-year period. DESIGN Randomized, prospective, patient- and examiner-masked clinical trial with intraindividual comparison. PARTICIPANTS Fifty-two patients with bilateral age-related cataract (104 eyes). METHODS Each study patient had cataract surgery in both eyes and received a 1-piece AcrySof IOL in 1 eye and a 3-piece AcrySof IOL in the other eye. Follow-up examinations were performed at 1 week, 1 month, 6 months, and 1, 2, and 5 years. Digital retroillumination images were obtained of each eye. The amount of posterior capsule opacification (score range, 0-10) was assessed subjectively at the slit lamp and objectively using automated image analysis software 1, 2, and 5 years after surgery. MAIN OUTCOME MEASURE Posterior capsule opacification score (scale, 0-10). RESULTS There was no significant difference between the 1-piece and 3-piece AcrySof IOL in best-corrected visual acuity, overlap of rhexis and IOL, capsular folds, anterior capsule opacification, and posterior capsule opacification (1-piece AcrySof PCO score, 1.7+/-1.7; 3-piece AcrySof PCO score, 1.3+/-1.4; P = 0.30). CONCLUSIONS Modification of the IOL haptic design of the sharp optic edged AcrySof IOL from a 3-piece to a 1-piece haptic design caused no significant change in PCO intensity and neodymium:yttrium-aluminium-garnet laser treatment rate 5 years after surgery.
Collapse
Affiliation(s)
- Christina Leydolt
- Department of Ophthalmology, Medical University of Vienna, Vienna, Austria.
| | | | | | | | | | | | | | | |
Collapse
|
66
|
Lee HI, Kim MK, Ko JH, Lee HJ, Wee WR, Lee JH. The efficacy of an acrylic intraocular lens surface modified with polyethylene glycol in posterior capsular opacification. J Korean Med Sci 2007; 22:502-7. [PMID: 17596661 PMCID: PMC2693645 DOI: 10.3346/jkms.2007.22.3.502] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
To investigate if the surface modification of intraocular lens (IOL) is efficient in the prevention of posterior capsular opacification (PCO), the acrylic surface of intraocular lens (Acrysof) was polymerized with polyethylene glycol (PEG-IOL). The human lens epithelial cells (1 x 10(4) cells/mL) were inoculated on PEG grafted or unmodified acrylic lenses for the control. The adherent cells on each IOL surface were trypsinized and counted. The every PEG-IOL was implanted in 20 New Zealand rabbits after removal of crystalline lens. The formations of PCO were checked serially through retroilluminated digital photography, and the severity scores were calculated using POCOman. The cell adherence patterns on each IOL were examined by scanning electron microscopy. As a result, the mean number of adherent cells of PEG-IOL (3.2+/-1.1 x 10(3)) tended to be smaller than that of the acrylic controls (3.6+/-1.9 x 10(3)) without a statistical significance (p=0.73). However, the mean severity of PCO formation in PEG-IOL was significantly lower than that in the control during the third to sixth weeks after surgery. Scanning electron microscopy revealed that the more patch-like cells were found firmly attached to the IOL surface in control than in the PEG-IOL. Conclusively, PEG polymerization to the acrylic IOL would possibly lessen the formation of PCO after cataract removal.
Collapse
Affiliation(s)
- Hyeon Il Lee
- Seoul Artificial Eye Center, Seoul National University Hospital Clinical Research Institute, Seoul, Korea
- Department of Ophthalmology, College of Medicine, Chung-Ang University, Seoul, Korea
| | - Mee Kum Kim
- Seoul Artificial Eye Center, Seoul National University Hospital Clinical Research Institute, Seoul, Korea
- Department of Ophthalmology, Seoul National University College of Medicine, Seoul, Korea
| | - Jung Hwa Ko
- Seoul Artificial Eye Center, Seoul National University Hospital Clinical Research Institute, Seoul, Korea
- Department of Ophthalmology, Seoul National University College of Medicine, Seoul, Korea
| | - Hyun Ju Lee
- Seoul Artificial Eye Center, Seoul National University Hospital Clinical Research Institute, Seoul, Korea
- Department of Ophthalmology, Seoul National University College of Medicine, Seoul, Korea
| | - Won Ryang Wee
- Seoul Artificial Eye Center, Seoul National University Hospital Clinical Research Institute, Seoul, Korea
- Department of Ophthalmology, Seoul National University College of Medicine, Seoul, Korea
| | - Jin Hak Lee
- Seoul Artificial Eye Center, Seoul National University Hospital Clinical Research Institute, Seoul, Korea
- Department of Ophthalmology, Seoul National University College of Medicine, Seoul, Korea
| |
Collapse
|
67
|
Yuen C, Williams R, Batterbury M, Grierson I. Modification of the surface properties of a lens material to influence posterior capsular opacification. Clin Exp Ophthalmol 2006; 34:568-74. [PMID: 16925705 DOI: 10.1111/j.1442-9071.2006.01278.x] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To study the effect of surface properties of materials on cellular behaviour and the formation of posterior capsular opacification (PCO). METHODS Polymethylmethacrylate, silicone and a hydrophobic acrylic were plasma treated and used in tissue culture. The changes in surface properties were quantified by dynamic contact angle measurements. Bovine lens epithelial cells (BLECs) were seeded onto these materials and cultured for 1 month. Serial photographs were taken. The cells were then fixed and stained to facilitate counting. RESULTS Plasma treatment significantly increased the hydrophilicity of surfaces. BLECs grew on all surfaces but significantly more cells adhered to the treated than the untreated surfaces. On the untreated surfaces the BLECs had a fibroblastic morphology whereas on the treated surfaces the cells maintained their epithelial morphology. CONCLUSIONS Posterior capsular opacification is a form of wound healing and the behaviour of lens epithelial cells is central to its progression. Emphasis has been on the elimination of residual lens epithelial cells to combat PCO. This study demonstrated that the phenotype of BLECs was influenced by the surface properties of the intraocular lens materials. Gas plasma treatment of the materials increased their hydrophilicity and allowed the adhered BLECs to maintain their normal epithelial morphology. We believe that controlled growth of lens epithelial cells may reduce the incidence of PCO.
Collapse
Affiliation(s)
- Conrad Yuen
- Ophthalmology, University Clinical Department, School of Clinical Sciences, University of Liverpool, Liverpool, UK.
| | | | | | | |
Collapse
|
68
|
Elgohary MA, Hollick EJ, Bender LE, Heatley CJ, Wren SM, Boyce J, Missotten T, Spalton DJ, Dowler JG. Hydrophobic acrylic and plate-haptic silicone intraocular lens implantation in diabetic patients. J Cataract Refract Surg 2006; 32:1188-95. [PMID: 16857508 DOI: 10.1016/j.jcrs.2006.01.106] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2005] [Accepted: 01/17/2006] [Indexed: 10/24/2022]
Abstract
PURPOSE To compare the capsular and uveal reaction after implantation of a plate-haptic silicone intraocular lens (IOL) (C11UB, Chiron) and a hydrophobic acrylic (AcrySof MA60, Alcon) IOL in diabetic patients. SETTING Moorfields Eye Hospital and St. Thomas' Hospital, London, United Kingdom. METHODS Thirty-five diabetic patients were recruited consecutively and randomly assigned to have implantation of either of the 2 IOLs. The percentage area of posterior capsule opacification (PCO), anterior capsule contraction (ACC), and postoperative inflammatory indices (flare and cells) were assessed objectively at 2 to 3 weeks, 6 months, and 1 year. Between-group and within-group analyses were conducted using the Student t test or Mann-Whitney test and Friedmann test, respectively. RESULTS Between-group analysis showed the percentage area of PCO was significantly greater in patients with plate-haptic silicone IOLs at 6 and 12 months (P = .002). At 6 months, ACC was significantly greater in the plate-haptic group (P = .04), but the difference was not significant at 12 months. There was higher flare in the hydrophobic acrylic IOL group than in the plate-haptic silicone IOL group at 2 to 3 weeks (P = .08). Within-group analysis showed that over the follow-up period, the plate-haptic silicone group, but not the hydrophobic acrylic group, had a progressive increase in PCO (P = .003). In the hydrophobic acrylic group, but not the plate-haptic silicone group, there was a significant reduction in the mean anterior chamber flare value (P = .01). There was no significant difference in visual acuity or contrast sensitivity at any postoperative visit. CONCLUSION In diabetic patients, hydrophobic acrylic IOLs can lead to an increased flare in the early postoperative period but they seem to be more favorable than plate-haptic silicone IOLs because the latter lead to more PCO.
Collapse
|
69
|
Hayashi K, Yoshida M, Hayashi H. Comparison of posterior capsule opacification between fellow eyes with two types of acrylic intraocular lens. Eye (Lond) 2006; 22:35-41. [PMID: 16823457 DOI: 10.1038/sj.eye.6702496] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
PURPOSE To compare the degree of posterior capsule opacification (PCO) and visual function between fellow eyes that received two different types of hydrophobic acrylic intraocular lenses (IOLs). METHODS Forty-five patients underwent bilateral phacoemulsification and implantation of an Alcon AcrySof IOL (MA60AC) in one eye and an AMO Sensar IOL (AR40e) in the fellow eye. The PCO density value was measured using the Scheimpflug videophotography system at 1, 6, 12, and 24 months after surgery. The incidence of eyes that required a neodymium:YAG (Nd:YAG) laser capsulotomy, visual acuity, and contrast sensitivity with and without a glare source were also examined. RESULTS The mean PCO value did not show a significant increase in either the AcrySof MA60AC or Sensar AR40e IOL groups, and was similar between the two groups throughout the 24-month follow-up period. The incidence of Nd:YAG laser capsulotomy was also the same between the groups. No significant difference was found in mean visual acuity between the two IOL groups during the follow-up, and there was no significant difference in photopic or mesopic contrast visual acuity with and without a glare source at 1 and 24 months after surgery. CONCLUSION The degree of PCO in eyes with an AcrySof IOL are almost the same as that in eyes with a Sensar IOL, with the results that visual acuity and contrast sensitivity with and without glare are similar.
Collapse
Affiliation(s)
- K Hayashi
- Private Hospital of Ophthalmology, Hayashi Eye Hospital, Hakata-Ku, Fukuoka, Japan.
| | | | | |
Collapse
|
70
|
Tognetto D, Sanguinetti G, Ravalico G. Tissue reaction to hydrophilic intraocular lenses. Expert Rev Med Devices 2006; 2:57-60. [PMID: 16293029 DOI: 10.1586/17434440.2.1.57] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The implant of intraocular lenses (IOLs) following cataract surgery induces a foreign body reaction to the IOL and a lens epithelial cell reaction. The host response to the IOL is mainly influenced by biomaterial properties. With the increasing use of phacoemulsification and small incision cataract surgery, there is growing interest in the use of foldable IOLs made of different materials. Hydrophilic acrylic IOLs include a wide group of foldable biomaterials different in terms of water content. These lenses have been reported to show a good biocompatibility after implantation. Nevertheless, tissue reaction to the implant of hydrophilic lenses is variable and not directly related to the hydrophilicity of their surface. A different adsorption of proteins on the IOL optic surface might be responsible for the different cellular reaction and lens epithelial cell response. Other properties besides hydrophilicity should be taken into account to classify IOL biomaterials.
Collapse
Affiliation(s)
- Daniele Tognetto
- Università di Trieste, Istituto di Clinica Oculistica, Ospedale Maggiore, Piazza Ospedale, 134129 Trieste, Italy
| | | | | |
Collapse
|
71
|
Vasavada AR, Raj SM, Johar K, Nanavaty MA. Effect of hydrodissection alone and hydrodissection combined with rotation on lens epithelial cells. J Cataract Refract Surg 2006; 32:145-50. [PMID: 16516794 DOI: 10.1016/j.jcrs.2005.11.027] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2005] [Accepted: 06/04/2005] [Indexed: 11/29/2022]
Abstract
PURPOSE To evaluate the impact of corticocleaving hydrodissection alone and hydrodissection combined with rotation on lens epithelial cells (LECs) and residual cortical fibers (RCFs). SETTING Iladevi Cataract and IOL Research Center, Ahmedabad, India. METHODS An experimental laboratory study of 20 fresh human cadaver eyes (10 pairs) was conducted. A single eye from each pair was assigned to the control group, in which no hydrodissection and no rotation were performed (control). The other eye was randomized to corticocleaving hydrodissection alone (Group 1) or corticocleaving hydrodissection with rotation (Group 2). Cataract extraction was standardized. Capsule polishing was omitted. Area of LEC loss (%) in the preequatorial zone (PZ) and equatorial zone (EZ) was calculated as: [Area of capsule without cells/Total area of capsule] x 100. Area of presence of RCFs (%) was calculated as: [Circumference of EZ of capsule with RCF/Total circumference of EZ of the capsule] x 100. The Mann-Whitney U and the Wilcoxon signed rank tests were applied. RESULTS In the control group, area of cell loss (%) was 3.9 +/- 3.2 in the PZ and 2.7 +/- 0.8 in the EZ; presence of RCFs (%) was 83.8 +/- 1.7. Area of LEC loss (%) in Groups 1 and 2 was 24.8 +/- 4.5 and 42.6 +/- 5.4 (P = .008) in the PZ and 22.4 +/- 2.1 and 54 +/- 2.5 (P = .008) in the EZ, respectively. Area of presence of RCFs (%) in Groups 1 and 2 was 34.2 +/- 3.7 and 23.7 +/- 3.7 (P = .008), respectively. CONCLUSION Corticocleaving hydrodissection combined with rotation removed significant quantities of LECs and RCFs.
Collapse
Affiliation(s)
- Abhay R Vasavada
- Iladevi Cataract & IOL Research Centre, Raghudeep Eye Clinic, Memnagar, Ahmedabad, India.
| | | | | | | |
Collapse
|
72
|
Schild G, Schauersberger J, Amon M, Abela-Formanek C, Kruger A. Lens epithelial cell ongrowth: Comparison of 6 types of hydrophilic intraocular lens models. J Cataract Refract Surg 2005; 31:2375-8. [PMID: 16473234 DOI: 10.1016/j.jcrs.2005.05.030] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/10/2005] [Indexed: 11/28/2022]
Abstract
PURPOSE To compare the ongrowth of lens epithelial cells (LECs) on the anterior surface of 6 different hydrophilic intraocular lenses (IOLs). SETTING Medical University of Vienna, Department of Ophthalmology and Optometry, Vienna, Austria. METHODS Six models of hydrophilic IOLs were compared in this prospective study: Visionflex A-100 (Distra Softcryl), Rayner Centerflex 570H (Rayner), Collamer CC4204BF-IOL (Staar), Injectacryl F 3000 (Distra), Hydroview H60M (Bausch & Lomb), and MemoryLens (ORC). Postoperative biomicroscopic examinations were performed 1, 3, 7, 30, 90, 180, and 365 days after surgery. Lens epithelial cells in each quadrant of the anterior capsule-free lens surface were graded. The product with the highest density and the number of quadrants with this density were used to measure LEC ongrowth. RESULTS The Hydroview and Visionflex IOLs showed significantly more LECs than the other IOLs starting on day 7 after surgery (P < .028). There was a statistically significant difference in LEC ongrowth on the Memory IOL compared with all other IOLs from day 30 onward (P < .001). The Rayner, Collamer and Injectacryl IOLs had the fewest LECs on the anterior surface compared with all other IOLs from day 7 until the final examination. CONCLUSIONS The findings show that LEC ongrowth on the IOL surface is material dependent. The findings suggest that the material of the recently developed hydrophilic IOLs induces less LEC ongrowth than older models.
Collapse
Affiliation(s)
- Gebtraud Schild
- Medical University of Vienna, Department of Ophthalmology and Optometry, Vienna, Austria.
| | | | | | | | | |
Collapse
|
73
|
Nishi O. [Influence of intraocular lens material and design on the development of posterior capsule opacification]. Ophthalmologe 2005; 102:572-8. [PMID: 15895236 DOI: 10.1007/s00347-005-1222-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
Based on the literature of 1999-2005, we attempted to clarify the influence of material and design of an intraocular lens (IOL) on the development of posterior capsule opacification (PCO) and identify the future problems to be solved. The sharp edge design of an IOL has significantly reduced PCO in recent years. Histopathological studies showed that a sharp capsular bend was formed at the sharp posterior optic edge, and the migration of lens epithelial cells was obviously inhibited at the site. Experimental and clinical studies suggest that the sharper the edge is, the sharper the capsular bend, and the greater the preventive effect, regardless of IOL material. The sharp capsule bend appears to represent a physical hindrance, which may induce contact inhibition of cell movement. How material participates in the preventive effect should be clarified in a future study. Thus, at the moment, the formation of capsular bend at the posterior optic edge appears to be the decisive criterion to evaluate the influence of IOL material and design on the development of PCO. Optimization of design and material of an IOL, which facilitates capsular bend formation as sharply and quickly as possible, may reduce PCO to a clinically negligible level.
Collapse
Affiliation(s)
- O Nishi
- Nishi Eye Hospital, Osaka, Japan.
| |
Collapse
|
74
|
Assaad NN, Cheung LM, Lim C, Francis IC, Coroneo MT, Alexander SL, Schumacher RS. Centripetal lens epithelial cell migration: a prospective study of the Alcon SA60AT intraocular lens. Clin Exp Ophthalmol 2005; 33:364-8. [PMID: 16033347 DOI: 10.1111/j.1442-9071.2005.01029.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
PURPOSE To evaluate prospectively the incidence and severity of centripetal lens epithelial cell migration (CLECM) onto the anterior surface of the Alcon SA60AT intraocular lens (IOL). METHODS One hundred and four consecutive cases of SA60AT IOL implantations were prospectively evaluated. At the 1-month postoperative visit, best corrected visual acuity (BCVA) was obtained. Following maximal pupillary dilatation, the extent of CLECM was assessed using a simplified grading scale (0-4). The centrality of the lens within the capsular bag was recorded. Patients with the highest grade of CLECM were recalled for reassessment at a minimum of 3 months. RESULTS Centripetal lens epithelial cell migration data were obtained on 99 patients. Of these, 94% demonstrated CLECM of varying severity at 1 month postoperatively. The severity was low grade in 54% of patients (29% grade 1, 24% grade 2), and high grade in 40% of patients (16% grade 3, 24% grade 4). BCVA results were good (91.9% 6/6 or better) and did not correlate with CLECM grade. Operative capsulorhexis size did not correlate with the severity of CLECM. The lens was well-centred in 91 of 92 patients in whom lens position was assessed. Twenty-three patients with grade 4 CLECM at 1 month were brought back for reassessment (3.5-13 months postoperatively) and 18 of these demonstrated complete regression of CLECM (to grade 0). CONCLUSIONS There is a high incidence and severity of CLECM 1 month postoperatively using the Alcon SA60AT IOL. There was no significant correlation between CLECM grade and either BCVA at 1 month, capsulorhexis size or lens centration. CLECM appears to be a frequent, benign and transient event with this lens.
Collapse
Affiliation(s)
- Nagi N Assaad
- Ophthalmic Surgery Centre, Sydney, New South Wales, Australia
| | | | | | | | | | | | | |
Collapse
|
75
|
Sacu S, Findl O, Linnola RJ. Optical coherence tomography assessment of capsule closure after cataract surgery. J Cataract Refract Surg 2005; 31:330-6. [PMID: 15767154 DOI: 10.1016/j.jcrs.2004.04.057] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/29/2004] [Indexed: 10/25/2022]
Abstract
PURPOSE To develop a technique for documenting and quantifying capsule bend formation in pseudophakic eyes, evaluate when the anterior and posterior lens capsules become completely apposed to the optic, and determine how soon a capsule bend is created at the optic edge of an intraocular lens (IOL) after cataract surgery. SETTING Medical University of Vienna, Department of Ophthalmology, Vienna, Austria. METHODS This prospective study comprised 33 eyes of 33 patients with age-related cataract who were scheduled to have cataract surgery. All eyes had phacoemulsification with implantation of 1 of 3 types of open-loop IOLs: 1-piece acrylic (SA60AT, Alcon), 3-piece acrylic (AcrySof MA60BM, Alcon), or 3-piece silicone (911A, AMO). Each group included 11 eyes. One and 3 days and 1, 2, 3, and 4 weeks after surgery, contact between the lens capsule and IOL optic as well as capsule bend formation were evaluated using optical coherence tomography (OCT). The postoperative times at which the capsule came into contact with the IOL optic and when the capsule bend formed were determined. RESULTS One day postoperatively, the mean distance between the anterior capsule and the IOL was 197 microm in the 1-piece acrylic IOL group, 161 microm in the 3-piece acrylic IOL group, and 220 microm in the 3-piece silicone IOL group. The posterior capsule was in contact with the IOL on the same day or earlier than the anterior capsule in 28 patients (85%). Postoperatively, the capsule bend formed at a mean of 10 days in the 1-piece acrylic group, 13 days in the 3-piece acrylic group, and 15 days in the 3-piece silicone group. The short-term reproducibility of the OCT technique was excellent (r = 0.99). CONCLUSIONS Optical coherence tomography produced cross-sectional tomograms of capsule-IOL contact in the early postoperative period. There was no significant difference in the time to capsule bend formation between the 3 IOLs. However, capsule bend formation at the optic edge occurred earlier with the 1-piece acrylic IOL than with the 3-piece silicone IOL.
Collapse
Affiliation(s)
- Stefan Sacu
- Department of Ophthalmology, Medical University of Vienna, Vienna, Austria
| | | | | |
Collapse
|
76
|
Schild G, Amon M, Abela-Formanek C, Schauersberger J, Bartl G, Kruger A. Uveal and capsular biocompatibility of a single-piece, sharp-edged hydrophilic acrylic intraocular lens with collagen (Collamer): 1-year results. J Cataract Refract Surg 2004; 30:1254-8. [PMID: 15177600 DOI: 10.1016/j.jcrs.2003.11.041] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/10/2003] [Indexed: 10/26/2022]
Abstract
PURPOSE To analyze uveal and capsular biocompatibility 1 year following implantation of a sharp-edged, hydrophilic, collagen-containing posterior chamber intraocular lens (IOL). SETTING Department of Ophthalmology, University of Vienna Medical School, Vienna, Austria. METHOD In a prospective study, a Collamer CC4204BF IOL was implanted in 30 eyes of patients with senile cataract. A standardized surgical technique and postoperative regimen were applied. To assess uveal biocompatibility, cellular inflammation on the anterior IOL surface was evaluated with a specular microscope. Capsular biocompatibility was registered semiquantitatively with a biomicroscope, based on an assessment of fibrosis on the anterior and posterior capsules. Tyndall values were measured with the Kowa FC-1000 laser flare-cell meter. Decentration of the lens was also registered. RESULTS One year after implantation, the values of flare and cell count in the anterior chamber were lower than preoperatively. Round and spindle-shaped, epithelioid, and foreign-body giant cells were not found on the anterior surface of the IOL. The capsulorhexis rim was moderately fibrosed in 56.6% of cases. Fibrosis of the capsule over the optic was also moderate in 36.6%. The central portion of the posterior capsule was devoid of fibrosis in 43.3% and mildly fibrosed in 50%. Three lenses revealed outgrowth of lens epithelial cells to the anterior surface of the IOL. A neodymium:YAG capsulotomy had to be performed in 1 case. All lenses were well centered in the capsular bag 1 year after implantation. CONCLUSIONS The absence of inflammatory cells on the anterior surface of the IOL indicates the high uveal biocompatibility of the lens. In terms of capsular biocompatibility, the results were satisfactory.
Collapse
Affiliation(s)
- Gebtraud Schild
- Department of Ophthalmology, University of Vienna, Medical School, Vienna, Austria
| | | | | | | | | | | |
Collapse
|
77
|
Izak AM, Werner L, Pandey SK, Apple DJ. Pathological evaluation of postmortem human eyes implanted with a new single-piece hydrophobic acrylic lens. J Cataract Refract Surg 2004; 30:1537-44. [PMID: 15210235 DOI: 10.1016/j.jcrs.2003.11.047] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/20/2003] [Indexed: 11/20/2022]
Abstract
PURPOSE To report the pathological findings in 14 human cadaver eyes implanted with a single-piece AcrySof(Alcon Laboratories) posterior chamber intraocular lens (IOL). SETTING David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. METHODS Fourteen human autopsy eyes implanted with a single-piece AcrySof (SA30AL) IOL were evaluated. The eyes were sectioned at the equatorial plane, and the anterior segment containing the IOL in the capsular bag was evaluated from a posterior perspective (Miyake-Apple view) and from an anterior perspective (surgeon's view) after removal of cornea and iris. They were then processed through paraffin, sectioned, and stained with hematoxylin-eosin, periodic acid-Schiff, and Masson's trichrome and examined under light microscopy. RESULTS All IOLs had symmetric in-the-bag fixation. Slight decentration was measured in 1 eye, which also had an anterior capsule tear. Grade 1 anterior capsule opacification was present in 9 eyes. No central posterior capsule opacification or posterior capsule folds were observed in any eye. Soemmering's ring formation was observed in 5 eyes. Zonular stretch caused by different degrees of capsular bag contraction was present in 4 eyes without decentration of the IOL. CONCLUSIONS Analyses of pseudophakic cadaver eyes from the posterior (Miyake-Apple) view, complemented by microscopic analyses, proved useful in the evaluation of IOL-capsular bag interaction. These studies are more important in cases of newly introduced lens designs.
Collapse
Affiliation(s)
- Andrea M Izak
- David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, Department of Ophthalmology and Visual Sciences, University of Utah, 50 North Medical Drive, Salt Lake City, UT 84132, USA
| | | | | | | |
Collapse
|
78
|
Davison JA. Neodymium:YAG laser posterior capsulotomy after implantation of AcrySof intraocular lenses. J Cataract Refract Surg 2004; 30:1492-500. [PMID: 15210228 DOI: 10.1016/j.jcrs.2003.11.042] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/25/2003] [Indexed: 11/28/2022]
Abstract
PURPOSE To report the incidence of neodymium:YAG (Nd:YAG) laser posterior capsulotomy after phacoemulsification and implantation of AcrySof (Alcon) intraocular lenses (IOLs). SETTING Private practice, Wolfe Clinic, Marshalltown, Iowa, USA. METHODS A retrospective diagnosis and procedure code review of 12419 consecutive cases having phacoemulsification and AcrySof IOL implantation from January 1995 through December 2002 was performed. The outcome parameter was the incidence of Nd:YAG laser posterior capsulotomies. RESULTS An Nd:YAG laser posterior capsulotomy was performed in 763 (6.1%) of the 12419 cases. The incidence of posterior capsulotomy was approximately 1% at 1 year, increasing in linear fashion by approximately 1% to 2% per year. CONCLUSIONS The Nd:YAG laser posterior capsulotomy rate after implantation of AcrySof IOLs was relatively low; the cumulative rate was approximately 1% to 2% new cases per year over a 7-year period, with a plateau suggested at year 6.
Collapse
Affiliation(s)
- James A Davison
- Wolfe Clinic, 309 East Church Street, Marshalltown, IA 50158, USA.
| |
Collapse
|
79
|
Affiliation(s)
- D F Chang
- 762 Altos Oaks Drive, Los Altos, CA 94024, USA;
| |
Collapse
|
80
|
Izak AM, Werner L, Pandey SK, Apple DJ, Vargas LG, Davison JA. Single-piece hydrophobic acrylic intraocular lens explanted within the capsular bag. J Cataract Refract Surg 2004; 30:1356-61. [PMID: 15177617 DOI: 10.1016/j.jcrs.2003.09.061] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/03/2003] [Indexed: 11/15/2022]
Abstract
A 74-year-old woman had uneventful phacoemulsification with implantation of a single-piece hydrophobic acrylic intraocular lens (IOL) (SA30AL) in her left eye. Two weeks after the surgery, the patient presented for ophthalmological consultation reporting pseudophakic dysphotopsia, which she had subjectively noted since surgery. Explantation/exchange of the IOL was performed 3 months after the surgery. The IOL was strongly attached to the capsule, which was fibrotic and contracted; explantation of the capsular bag complex in toto was done. To our knowledge, this is the first case of explantation of this IOL design with clinicopathological correlation.
Collapse
Affiliation(s)
- Andrea M Izak
- Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, USA
| | | | | | | | | | | |
Collapse
|
81
|
Vasavada AR, Raj SM. Anterior capsule relationship of the AcryS of intraocular lens optic and posterior capsule opacification. Ophthalmology 2004; 111:886-94. [PMID: 15121364 DOI: 10.1016/j.ophtha.2003.08.039] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2002] [Accepted: 08/26/2003] [Indexed: 10/26/2022] Open
Abstract
OBJECTIVE To evaluate the relationship of the anterior capsule and the AcrySof MA30BA intraocular lens (IOL) and its impact on the development of central posterior capsule opacification (PCO). DESIGN Prospective, randomized, controlled trial. PARTICIPANTS Two hundred two patients with senile cataracts received an AcrySof IOL between July and December 1998 at Iladevi Cataract and IOL Research Center, Ahmedabad, India. INTERVENTION Patients were randomized prospectively to receive 1 of the 3 possibilities of anterior capsule and IOL optic relationship: group 1, total anterior capsule cover (360 degrees ) of the optic; group 2, no anterior capsule cover (360 degrees ) of the optic; group 3, partial anterior capsule cover (<360 degrees ) of the optic. After surgery, slit-lamp video photography was performed every 6 months for 3 years. Analyses of variance and chi-square tests were used to compare treatment groups. MAIN OUTCOME MEASURES Incidence of PCO in the 3 groups. The posterior capsule was divided into 3 zones: peripheral, central 3 mm, and midperipheral (the space between the peripheral and the central zones). RESULTS The average follow-up was 35.3 +/- 1.52 months in all the groups. At 3 years, the rate of central PCO was 6.4% in group 1, 7.1% in group 2, and 5.9% in group 3 (P = 0.9). Midperipheral PCO was present in 24.2% in group 1, 16% in group 2, and 20.6% in group 3 (P = 0.9). Peripheral PCO was seen in 100% of patients in all groups. The neodynium:yttrium-aluminum-garnet laser (Nd:YAG) posterior capsulotomy rate was 0% in all groups. CONCLUSIONS There was no significant difference in the incidence of development of central PCO among the 3 groups. No patient experienced central PCO that required Nd:YAG capsulotomy. When using the AcrySof IOL model MA30BA, the relationship of the anterior capsule and the IOL does not seem to be a factor that relates to the development of central PCO.
Collapse
Affiliation(s)
- Abhay R Vasavada
- Iladevi Cataract & IOL Research Centre, Raghudeep Eye Clinic, Ahmedabad, India.
| | | |
Collapse
|
82
|
Evans MDM, Pavon-Djavid G, Hélary G, Legeais JM, Migonney V. Vitronectin is significant in the adhesion of lens epithelial cells to PMMA polymers. J Biomed Mater Res A 2004; 69:469-76. [PMID: 15127394 DOI: 10.1002/jbm.a.30017] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
A major complication of intraocular lens surgery is diminished visual acuity caused by the regrowth of lens epithelial cells (secondary cataract). Polymethylmethacrylate (PMMA) is a commonly used intraocular lens material. This study addresses the mechanisms underlying the initial adhesion of lens epithelial cells to PMMA and a functionalized PMMA-based terpolymer known to inhibit cell proliferation. Rabbit lens epithelial cells were cultured on the test polymer surfaces in medium containing serum depleted of either fibronectin or vitronectin (or both) to identify the role of these proteins in the initial process of cell adhesion. Adherent cells were quantitated after 60 min, and the actin cytoskeleton and focal contact formation were compared in each serum treatment on both polymers. Vitronectin was significantly more effective for initial cell attachment to both polymers than fibronectin. Normal cell spreading on PMMA required vitronectin and was independent of fibronectin, whereas cell spreading on the terpolymer was abnormal and required the presence of fibronectin and vitronectin together. Together, these results help to explain the inhibition of cell proliferation previously shown on the functionalized PMMA. This work contributes to the design of a polymer for use in intraocular lenses that inhibits proliferation of the target cells.
Collapse
Affiliation(s)
- Margaret D M Evans
- CSIRO Molecular Science, 11 Julius Avenue, North Ryde, Sydney, NSW, Australia 2113.
| | | | | | | | | |
Collapse
|
83
|
Abstract
Surgery for cataract removal has become successively refined such that posterior capsular opacification is the most common problem presenting after modern cataract extraction. Various techniques and treatments exist to manage patients with posterior capsular opacification using Nd:YAG capsulotomy. There are many possible variations in initial assessment, pre-laser treatments, laser techniques, and follow-up routines. The literature on the use of Nd:YAG laser for capsulotomy was reviewed and interpreted. This article presents the currently available knowledge in a format that allows the practitioner to tailor an evidence-based protocol for treating patients with symptomatic posterior capsule opacification.
Collapse
|
84
|
Tognetto D, Toto L, Sanguinetti G, Cecchini P, Vattovani O, Filacorda S, Ravalico G. Lens epithelial cell reaction after implantation of different intraocular lens materials. Ophthalmology 2003; 110:1935-41. [PMID: 14522768 DOI: 10.1016/s0161-6420(03)00736-x] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
PURPOSE To determine the influence of intraocular lens (IOL) material on anterior capsular opacification and membrane growth over the anterior IOL surface in patients who have undergone standardized small-incision cataract surgery and foldable IOL implantation in the capsular bag. DESIGN Randomized controlled trial. PARTICIPANTS Eighty-eight cataract patients (88 eyes). METHODS Patients were randomly assigned to receive one of four different foldable IOLs after phacoemulsification: Storz Hydroview H60M, Corneal ACR6D, AMO SI40NB, and Alcon AcrySof MA60BM. Examinations on days 7, 30, 90, 180, 360, and 720 after surgery included ophthalmologic examination, slit-lamp biomicroscopy, and photography using red reflex and focal illumination of the anterior IOL surface. MAIN OUTCOME MEASURES Best-corrected visual acuity was measured at each examination. In addition, the anterior capsule opacification and the membrane growth on the anterior IOL surface were graded according to a subjective method by the same researcher. RESULTS The fibrosis of the anterior capsule was more frequently observed in the group using Corneal ACR6D and AMO SI40NB. The Hydroview and ACR6D groups showed a higher percentage of cases with membrane growth from the rhexis edge on the anterior IOL surface. AcrySof showed the lowest presence of fibrosis of the anterior capsule, and no membrane growth was noted. CONCLUSIONS Anterior capsule opacification is an index of IOL biocompatibility. The natural location of lens epithelial cells (LECs) precludes the possibility of the IOL's design influencing the anterior capsule behavior. The local response of LECs varies according to the IOL studied. This may be related to the chemical and physical properties of the materials used in the different IOLs.
Collapse
Affiliation(s)
- Daniele Tognetto
- Eye Clinic, University of Trieste, Ospedale Maggiore, Piazza Ospedale, 1-34129 Trieste, Italy.
| | | | | | | | | | | | | |
Collapse
|
85
|
Abhilakh Missier KA, Nuijts RMMA, Tjia KF. Posterior capsule opacification: silicone plate-haptic versus AcrySof intraocular lenses. J Cataract Refract Surg 2003; 29:1569-74. [PMID: 12954308 DOI: 10.1016/s0886-3350(02)02046-1] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
PURPOSE To evaluate posterior capsule opacification (PCO) in fellow eyes, 1 receiving a silicone intraocular lens (IOL) and the other, an acrylate IOL. SETTING Department of Ophthalmology, Isala Clinics, Zwolle, The Netherlands. METHODS This retrospective study comprised 107 patients (214 eyes). In each patient, 1 eye was randomly selected to have implantation of an acrylate IOL (AcrySof MA30BA or MA60BM, Alcon) and the other eye, a plate-haptic silicone IOL (AA4203VF, Staar). Outcome measures were the total PCO index, percentage of neodymium:YAG (Nd:YAG) capsulotomies performed, and logMAR best corrected visual acuity (BCVA). The follow-up was 3 years. RESULTS The total PCO index was significantly lower in the AcrySof group than in the plate-haptic silicone group (P<.0001). There was no significant difference in logMAR BCVA between groups (P>.05). The percentage of Nd:YAG laser treatments was significantly lower in the AcrySof group (2.8%) than in the plate-haptic silicone group (23.1%) (P<.05). CONCLUSIONS There was significantly less PCO and a lower Nd:YAG laser capsulotomy rate after AcrySof IOL implantation than after plate-haptic silicone IOL implantation. These results did not seem to affect the logMAR BCVA as there were no significant differences between groups in this parameter.
Collapse
|
86
|
Tognetto D, Toto L, Minutola D, Ballone E, Di Nicola M, Di Mascio R, Ravalico G. Hydrophobic acrylic versus heparin surface-modified polymethylmethacrylate intraocular lens: a biocompatibility study. Graefes Arch Clin Exp Ophthalmol 2003; 241:625-30. [PMID: 12883913 DOI: 10.1007/s00417-003-0711-z] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2003] [Revised: 04/30/2003] [Accepted: 05/08/2003] [Indexed: 10/26/2022] Open
Abstract
BACKGROUND The implant of intraocular lenses (IOLs) following cataract surgery induces a foreign-body reaction to the IOL and a response on the part of the lens epithelial cells (LECs). The purpose of this study was to compare these aspects after the implantation of two different IOL materials. METHODS Thirty-six cataract patients were randomised to receive two different foldable lens: an acrylic hydrophobic IOL (Acrysof MA30BA) and a heparin surface-modified (HSM) polymethylmethacrylate IOL (Pharmacia & Upjohn 809C) after phacoemulsification. Slit-lamp biomicroscopy with specular technique was used to assess the inflammatory cell adhesion on the anterior IOL surface, anterior capsule opacification (ACO) and membrane growth from the rhexis edge at 7, 30, 90, 180 and 360 days after surgery. RESULTS The 809C group showed a higher percentage of patients with slight inflammatory cell adhesion on the anterior cell surface and a higher small cellular density during the whole follow-up period. The epithelioid cell response was greater in the 809C group than the Acrysof group but the difference between the two groups was not statistically significant. The ACO increased during the follow-up in both groups but was significantly higher in the 809C group. CONCLUSION Acrysof lenses are more biocompatible than HSM IOLs, showing a lower grade of inflammatory cell adhesion and ACO. The implantation of these lenses may be particularly indicated in patients with pathologies predisposing to blood-aqueous barrier damage.
Collapse
Affiliation(s)
- Daniele Tognetto
- Eye Clinic, University of Trieste, Ospedale Maggiore, Piazza Ospedale, 1, 34129 Trieste, Italy.
| | | | | | | | | | | | | |
Collapse
|
87
|
Abstract
PURPOSE The choice of intraocular lens (IOL) implanted by cataract surgeons has significant implications for the effectiveness of the operation and the subsequent need for capsulotomy. METHODS Comparison of pertinent peer-reviewed literature published from 1996 through 2001 obtained from a MEDLINE literature search on biocompatibility indicators and IOLs. This review pertains to routine, uncomplicated cataract surgery, and thus, the findings may not be relative to complicated surgeries. Currently available IOLs were not included in this review if no published data on the IOL were available. However, representative lenses from all the major biomaterial classes were included. RESULTS Overall results of a comparison of published accounts of posterior capsular opacification, Nd:YAG capsulotomies, anterior capsular opacification, aqueous flare, cellular reaction, capsular adhesion, and capsular stability show a polyacrylic elastomer to be the most highly biointegrated IOLs by the human eye. CONCLUSIONS Most evidence published in peer-reviewed journals suggests a clear IOL choice for cataract surgeons. In the field of implantable medical devices, one device in a category does not usually provide consistently superior performance of its intended function. The ability of the biomaterial to maintain a clear optical axis not only by suppressing the proliferation of lens epithelial cells, and thus inhibiting posterior capsular opacification formation and obviating the need for an Nd:YAG capsulotomy, but also by adhering to and stabilizing the capsular bag is, to date, unmatched by any other IOL available.
Collapse
Affiliation(s)
- James P McCulley
- Department of Ophthalmology, The University of Texas Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, TX 75390-9057, USA.
| |
Collapse
|
88
|
Linnola RJ, Sund M, Ylönen R, Pihlajaniemi T. Adhesion of soluble fibronectin, vitronectin, and collagen type IV to intraocular lens materials. J Cataract Refract Surg 2003; 29:146-52. [PMID: 12551682 DOI: 10.1016/s0886-3350(02)01422-0] [Citation(s) in RCA: 59] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
PURPOSE To evaluate soluble fibronectin, vitronectin, and collagen type IV adhesion to poly(methyl methacrylate) (PMMA), fluorine-surface-modified PMMA, silicone, hydrophobic and hydrophilic acrylate, and hydrogel intraocular lenses (IOLs) and determine whether hydrophobic and hydrophilic acrylate materials have different fibronectin-adhesion properties. SETTING Department of Medical Biochemistry, University of Oulu, Oulu, Finland. METHODS One hundred fifty IOLs were incubated for 1 week at 37 degrees C with radioactive-iodine-labeled soluble fibronectin, vitronectin, or collagen type IV. Fifty IOLs were analyzed for each protein, 5 from each of 10 different IOL models (PMMA, Alcon MC60BM; fluorine-surface-modified PMMA, Chiron Fluorilens Centra-55F; silicone, Allergan Medical Optics SI-40NB and Pharmacia and Upjohn CeeOn 911A; hydrophobic soft acrylate, Alcon AcrySof MA60BM and SA30AL and AMO Sensar; hydrophilic soft acrylate, Ioltech Stabibag and Bausch and Lomb BL27; and hydrogel, Bausch and Lomb Hydroview. The amount of adherent protein was measured with a gamma counter at 1 and 7 days and expressed as counts per minute. RESULTS At 1 week, significantly more fibronectin was bound to the hydrophobic acrylate IOLs than to the 2-hydroxyethyl methacrylate (HEMA) containing hydrophilic acrylate IOLs (P <.05 to.0001). Significantly more vitronectin was bound to the 2 silicone IOLs than to any other IOL (P <.01 to.0001) at 7 days. Collagen type IV adhered best to the hydrophilic acrylate IOLs, which were significantly different (P <.01 to.0001) than the other IOLs at 1 and 7 days. CONCLUSIONS Each IOL material had a different affinity to each protein. Significant binding to 1 protein does not indicate that the IOL will bind significantly to all proteins; instead, each protein should be studied separately. Fibronectin bound significantly better to hydrophobic acrylate IOLs than to hydrophilic acrylate IOLs, suggesting that the HEMA-containing IOLs should be classified with the hydrogel IOL group.
Collapse
|
89
|
Vargas LG, Peng Q, Apple DJ, Escobar-Gomez M, Pandey SK, Arthur SN, Hoddinott DSM, Schmidbauer JM. Evaluation of 3 modern single-piece foldable intraocular lenses: clinicopathological study of posterior capsule opacification in a rabbit model. J Cataract Refract Surg 2002; 28:1241-50. [PMID: 12106735 DOI: 10.1016/s0886-3350(02)01216-6] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE To assess the development of posterior capsule opacification (PCO) with 3 modern single-piece foldable intraocular lenses (IOLs) in a histopathological study and to compare the potential preventive effects of the IOL design and biomaterial in retarding PCO. SETTING Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. METHODS Thirty-one rabbit eyes were randomly operated on with phacoemulsification and implantation of 3 single-piece foldable lenses: a hydrophilic acrylic design, the Rayner Centerflex 570H (n = 11); a hydrophobic acrylic design, the Alcon AcrySof SA30AL (n = 10); and a silicone large-hole plate design, the Staar AA-4203VF (n = 10). Central PCO (CPCO), peripheral PCO (PPCO), and Soemmering's ring formation were evaluated 3 weeks after surgery using the Miyake-Apple posterior photographic technique. Histological sections of each globe were prepared to document capsular bag status and performance of IOL geometry. RESULTS The acrylic IOLs (Centerflex and AcrySof) had lower CPCO and PPCO scores than the silicone plate IOL (P <.05). There was no significant difference in Soemmering's ring formation among the 3 models. Pathological evaluations revealed effective blockage of migrating lens epithelial cells (LECs) at the site of the truncated optic edge of the Centerflex and AcrySof IOLs, even in the presence of large amounts of retained/regenerative cortical material. CONCLUSIONS The AcrySof IOL has a hydrophobic surface and the Centerflex a hydrophilic surface, but no correlation to these characteristics could be identified. The single-piece AcrySof optic geometry created a clear-cut barrier effect equal to that of its 3-piece predecessor. The anatomic profile of the Centerflex IOL shows the same characteristics. The optics of both acrylic lenses have square truncated edges that functionally block ingrowth of migrating LECs toward the central visual axis, leaving clear posterior capsules. The square optic edge was an appropriate geometric configuration to create a barrier effect. There was no effect of the biomaterial on PCO prevention.
Collapse
Affiliation(s)
- Luis G Vargas
- Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston, South Carolina 29425-5536, USA
| | | | | | | | | | | | | | | |
Collapse
|
90
|
Aasuri MK, Shah U, Veenashree MP, Deshpande P. Performance of a truncated-edged silicone foldable intraocular lens in Indian eyes. J Cataract Refract Surg 2002; 28:1135-40. [PMID: 12106721 DOI: 10.1016/s0886-3350(01)01254-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
PURPOSE To study the role of truncated-edged silicone foldable intraocular lenses (IOLs) in preventing posterior capsule opacification (PCO) in Indian eyes. SETTING Cornea and Anterior Segment Service, L.V. Prasad Eye Institute, Hyderabad, India. METHODS This prospective study evaluated 39 Indian patients (39 eyes) with a mean age of 55.4 years who had uneventful implantation of the CeeOn Edge 911A IOL (Pharmacia). All IOLs were placed in the bag. Except in 4 patients, the capsulorhexis margin overlapped 360 degrees on the IOL optic periphery. The mean follow-up was 10.9 months (range 6.5 to 13.0 months); 32 patients were followed for 1 year. RESULTS Intraoperatively, posterior capsule fibrosis was noted in 7 patients. Diffuse haze was noted in the IOL optic in 1 patient. Clinically significant PCO did not occur in any case. One patient had clinically nonsignificant (grade 1) PCO at the 6- and 12-month follow-up visits. Although epithelial pearl accumulation (Soemmering's ring) was seen beyond the edge of the IOL in the 32 patients followed for 1 year, the epithelial pearls were central only in the patient with grade 1 PCO. Significant cell deposits were noted in 1 patient who had fibrinous uveitis at the 1-week postoperative visit; both resolved by 1 month. All eyes achieved a best corrected visual acuity of 20/30 or better. CONCLUSIONS The CeeOn Edge 911A IOL was well tolerated in Indian eyes, and the posterior capsule remained clear. Larger patient groups with a longer follow-up will provide more useful information.
Collapse
Affiliation(s)
- Murali K Aasuri
- Cornea and Anterior Segment Service, L.V. Prasad Eye Institute, Hyderabad, India.
| | | | | | | |
Collapse
|
91
|
Abela-Formanek C, Amon M, Schauersberger J, Kruger A, Nepp J, Schild G. Results of hydrophilic acrylic, hydrophobic acrylic, and silicone intraocular lenses in uveitic eyes with cataract: comparison to a control group. J Cataract Refract Surg 2002; 28:1141-52. [PMID: 12106722 DOI: 10.1016/s0886-3350(02)01425-6] [Citation(s) in RCA: 112] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE To evaluate the uveal and capsular biocompatibility of hydrophilic acrylic, hydrophobic acrylic, and silicone intraocular lenses (IOLs) in eyes with uveitis. SETTING Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS This prospective study comprised 72 eyes with uveitis and 68 control eyes having phacoemulsification and IOL implantation by 1 surgeon. Patients received 1 of the following IOLs: foldable hydrophilic acrylic (Hydroview, Bausch & Lomb), hydrophobic acrylic (AcrySof, Alcon), or silicone (CeeOn 911, Pharmacia). Postoperative evaluations were at 1, 3, and 7 days and 1, 3, and 6 months. Cell reaction was evaluated by specular microscopy of the anterior IOL surface and the anterior and posterior capsule reaction, by biomicroscopy. RESULTS Small round cell deposition was observed on all IOLs in the immediate postoperative period, especially in eyes with uveitis. This reaction decreased 3 to 6 months after surgery. Although the CeeOn 911 had a higher mean grade of small cells, there was no statistical difference between the 3 IOL types after 6 months in the uveitis and control groups. Foreign-body giant cells (FBGCs) increased after 1 week to 1 month. The AcrySof IOLs had the highest number of FBGCs; after 6 months, there was a statistically significant difference between the AcrySof and Hydroview uveitis groups (P =.036) and the AcrySof and CeeOn 911 uveitis groups (P =.003) but there was no difference among the 3 IOL types in the control group. Lens epithelial cell outgrowth persisted on the Hydroview IOLs in control eyes and regressed on all 3 IOL types in uveitic eyes and on the AcrySof and CeeOn 911 IOLs in control eyes (P =.0001). Anterior capsule opacification (ACO) was more severe on all IOL types in uveitic eyes and on the CeeOn 911 IOL in control eyes. Posterior capsule opacification (PCO) was more severe in uveitic eyes. The Hydroview group had more severe PCO than the AcrySof and the CeeOn 911 groups in uveitis and control eyes. Six months postoperatively, the difference was significant (P =.0001). There was no significant difference between the AcrySof and CeeOn 911 IOLs. CONCLUSIONS Intraocular lens biocompatibility is inversely related to inflammation. Hydrophilic acrylic material had good uveal but worse capsular biocompatibility. Hydrophobic acrylic material had lower uveal but better capsular biocompatibility. Silicone showed a higher small cell count (mild) and more severe ACO but achieved PCO results comparable to FBGC results and better than those with the AcrySof lens 6 months after surgery. Despite the differences in IOL biocompatibility, all patients benefited from the surgery.
Collapse
|
92
|
Trivedi RH, Werner L, Apple DJ, Pandey SK, Izak AM. Post cataract-intraocular lens (IOL) surgery opacification. Eye (Lond) 2002; 16:217-41. [PMID: 12032712 DOI: 10.1038/sj.eye.6700066] [Citation(s) in RCA: 60] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
Intraocular lens (IOL) implantation has no doubt been one of the most satisfying advances of medicine. Millions of individuals with visual disability or frank blindness from cataracts had and continue to have benefit from this procedure. It has been reported by ophthalmologists that the modern cataract-intraocular lens (IOL) surgery is safe and complication-free most of the time. This makes the watchword for any cataract surgeon to be 'implantation,' 'implantation,' 'implantation.' In the mid-1980s, as IOLs were evolving rapidly, the watchword of the implant surgeon was 'fixation,' 'fixation,' 'fixation.' Most techniques, lenses and surgical adjuncts now allow us to achieve the basic requirement for successful IOL implantation, namely long-term stable IOL fixation in the capsular bag. However despite this advancement some items 'slipped through cracks.' In this article, we would like to alert the reader to a new watchword, namely 'opacification,' 'opacification,' 'opacification.' Here we will be talking about the good, the bad, and the ugly. Examples of the 'good' include the recent successes now being achieved in reducing the incidence of posterior capsule opacification. Examples of the 'bad' include various proliferations of anterior capsule cells, problems caused by silicone oil adherence to IOLs and problems with piggyback IOLs. The 'ugly' include the sometimes striking and often visually disabling opacifications occurring on and within IOL optics, both on some modern foldable IOLs as well as a poly(methyl methacrylate) (PMMA) optic degradation occurring with some models a decade or more after implantation.
Collapse
Affiliation(s)
- R H Trivedi
- Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, SC 29425-5536, USA
| | | | | | | | | |
Collapse
|
93
|
Tognetto D, Toto L, Ballone E, Ravalico G. Biocompatibility of hydrophilic intraocular lenses. J Cataract Refract Surg 2002; 28:644-51. [PMID: 11955905 DOI: 10.1016/s0886-3350(01)01158-0] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
PURPOSE To assess the biocompatibility of 3 hydrophilic acrylic intraocular lenses (IOLs) by evaluating the postoperative cell reaction on the IOL surface, anterior capsule opacification (ACO) rate, and presence of membrane growth over the anterior IOL surface. SETTING University Eye Clinic of Trieste, Trieste, Italy. METHODS In this prospective study, 73 patients were randomized to receive 1 of 3 types of hydrogel IOLs after phacoemulsification: Storz Hydroview H60M, Corneal ACR6D, or Ioltech Stabibag. To analyze and photograph the anterior IOL surface, slitlamp biomicroscopy and specular microscopy were performed 7, 30, 90, and 180 days after surgery. Small, epithelioid, and giant inflammatory cell reaction was evaluated. In addition, ACO and membrane growth on the anterior IOL surface were assessed. RESULTS Low inflammatory cell adhesion was observed on the anterior surface of all 3 IOLs. The Stabibag group had a significantly higher grade of small inflammatory cell reaction 7 and 30 days after surgery. A significantly higher rate of ACO was observed in the ACR6D group. The Hydroview and ACR6D groups had a significantly higher percentage of membrane growth from the capsulorhexis edge onto the anterior IOL surface than the Stabibag group. CONCLUSIONS Clinically, the 3 hydrophilic IOLs behaved in a different manner, showing the different forms of biocompatibility. Results indicate that a different chemical composition determines correspondingly different protein absorption on IOL surfaces. This might result in a different adhesion pattern and spreading of lens epithelial and inflammatory cells.
Collapse
|
94
|
Biswas J, Kumar SK. Cytopathology of explanted intraocular lenses and the clinical correlation. J Cataract Refract Surg 2002; 28:538-43. [PMID: 11973105 DOI: 10.1016/s0886-3350(01)01159-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
PURPOSE To study the cytopathological features of explanted intraocular lenses (IOLs) and correlate the features with their clinical presentation. SETTING Ocular Pathology Department, Medical and Vision Research Foundation, Sankara Nethralaya, Chennai, India. METHODS The study comprised 61 explanted IOLs (48 posterior chamber IOLs and 13 anterior chamber IOLs) removed for the following reasons: pseudophakic bullous keratopathy (36), recalcitrant uveitis (7), retinal detachment (10), endophthalmitis (5), uveitis (7), IOL subluxation (2), and painful blind eye (1). The IOLs were stained with hematoxylin and eosin using a simple cytological technique. The cytopathological features were studied and correlated with the clinical presentations. RESULTS The mean time of IOL explantation was 10.1 months after surgery. Twenty-one IOLs had granulomatous and nongranulomatous inflammations and 4, nongranulomatous inflammations. One IOL had fungal filaments on the surface. CONCLUSIONS Intraocular lenses can produce both granulomatous and nongranulomatous inflammation. Granulomatous inflammation was the most common in this series. The surface of IOLs explanted because of intraocular infection may show infective agents.
Collapse
|
95
|
Abstract
Modern cataract surgery is constantly evolving and improving in terms of lens material and design. Researchers and physicians strive to obtain better refractive correction with smaller wound size and minimizing host cell response to limit the proliferation of lens epithelial cells leading to opacification of the lens capsule. Intraocular lens material varies in water content, refractive index, and tensile strength. Intraocular lens design has undergone revisions to prohibit lens epithelial cell migration and reflection of internal and external light. The evolution of intraocular lens and extracapsular cataract surgery has lead to faster postoperative recovery and better visual outcomes.
Collapse
Affiliation(s)
- Kim T Doan
- Department of Ophthalmology, John A. Moran Eye Center, University of Utah, 50 North Medical Drive, Salt Lake City, UT 84132, USA
| | | | | |
Collapse
|
96
|
Wilson ME, Elliott L, Johnson B, Peterseim MM, Rah S, Werner L, Pandey SK. AcrySof acrylic intraocular lens implantation in children: clinical indications of biocompatibility. J AAPOS 2001; 5:377-80. [PMID: 11753259 DOI: 10.1067/mpa.2001.119786] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
PURPOSE To assess the clinical biocompatibility of AcrySof (Alcon, Ft Worth, Tex) acrylic intraocular lenses (IOLs) in the highly reactive eyes of infants and children. METHODS A database of 230 pediatric IOL implantations was queried to allow retrospective review of all eyes implanted with an AcrySof IOL. Eyes implanted with polymethyl methacrylate (PMMA) IOLs were also reviewed and were used as a historical comparison group. Follow-up examinations were conducted by the surgeon on postoperative day 1, day 7, week 4, and week 8 and every 3 months during the first year and every 6 months thereafter. The presence of synechiae, lens deposits, and posterior capsule opacification were noted in the record at each visit. Examination notes were photocopied, and data were extracted from each visit note and entered into a computerized database. RESULTS One hundred and ten eyes had an AcrySof IOL at an average age of 60.4 months and had an average postoperative follow-up of 64.6 weeks. In comparison, 120 eyes had PMMA IOLs inserted at an average age of 71.9 months with an average postoperative follow-up of 136.9 weeks. IOL cell deposits were seen at the slit lamp in 7 of 110 (6.4%) AcrySof lenses as compared with 26 of 120 (21.75%) PMMA lenses (P =.002). Posterior synechiae were seen in 5 of 110 (4.5%) AcrySof lenses as compared with 23 of 120 (19.2%) PMMA lenses (P =.001). Twenty-two AcrySof-implanted eyes had an intact posterior capsule. Twenty-eight PMMA-implanted eyes had an intact posterior capsule. The YAG laser capsulotomy rate was similar in the 2 groups at 45.4% for AcrySof and 50% for PMMA (P =.973). The average time from surgery to YAG posterior capsulotomy was 18.6 months with an AcrySof lens and 18.3 months with a PMMA lens (P =.951; t test). A total of 60 patients (68%) implanted with AcrySof IOLs were able to cooperate for Snellen visual acuities. Of their 67 eyes, 48 (72%) had a 20/40 or better visual acuity at the last follow-up examination, and 63 eyes (94%) had a 20/100 or better visual acuity. Thirty-five eyes (52%) required amblyopia therapy, and patching continues as needed. CONCLUSIONS The AcrySof IOL is representative of a new group of foldable IOLs made from flexible hydrophobic acrylic material. The AcrySof IOL appears clinically to be biocompatible when placed in the eyes of children despite the increased tissue reactivity known to occur in young patients.
Collapse
Affiliation(s)
- M E Wilson
- N. Edgar Miles Center for Pediatric Ophthalmology, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina 29425, USA.
| | | | | | | | | | | | | |
Collapse
|
97
|
Schmidbauer JM, Vargas LG, Peng Q, Escobar-Gomez M, Werner L, Arthur SN, Apple DJ. Posterior capsule opacification. Int Ophthalmol Clin 2001; 41:109-31. [PMID: 11481543 DOI: 10.1097/00004397-200107000-00010] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Affiliation(s)
- J M Schmidbauer
- Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston, SC 29425, USA
| | | | | | | | | | | | | |
Collapse
|
98
|
|
99
|
Apple DJ, Peng Q, Visessook N, Werner L, Pandey SK, Escobar-Gomez M, Ram J, Auffarth GU. Eradication of posterior capsule opacification: documentation of a marked decrease in Nd:YAG laser posterior capsulotomy rates noted in an analysis of 5416 pseudophakic human eyes obtained postmortem. Ophthalmology 2001; 108:505-18. [PMID: 11237905 DOI: 10.1016/s0161-6420(00)00589-3] [Citation(s) in RCA: 209] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
Abstract
OBJECTIVE (1) To report the neodymium:yttrium-aluminum-garnet (Nd:YAG) laser posterior capsulotomy rate (%) of eight rigid and foldable intraocular lens (IOL) designs in a series of 5416 pseudophakic human eyes obtained postmortem, accessioned in our center between January 1988 and January 2000. (2) To identify factors that are instrumental in reducing the incidence of posterior capsule opacification, (PCO, secondary cataract) and hence the need for Nd:YAG laser posterior capsulotomy. DESIGN Comparative autopsy tissue analysis. PARTICIPANTS A total of 5416 globes with posterior chamber intraocular lens (PC-IOLs) obtained postmortem received from Lions Eye Banks between 1988 and 2000. METHODS Miyake-Apple posterior photographic technique. Special reference was given to the presence or absence of Nd:YAG laser posterior capsulotomy orifice on the posterior capsule of each eye. MAIN OUTCOME MEASURES The Nd:YAG laser posterior capsulotomy rate (%) as of January 2000 was documented. In addition, the Nd:YAG laser posterior capsulotomy rate for each lens was plotted on a monthly basis for the same period, creating a computerized trend or "timeline" for each IOL style. RESULTS Relatively high Nd:YAG laser posterior capsulotomy rates ranging from 20.3% to 33.4% were noted with four relatively older designs (high incidence of implantation between 1988 and the early 1990s). Four modern foldable IOLs manufactured from silicone and acrylic materials had significantly lower Nd:YAG laser posterior capsulotomy rates ranging from 0.9% (Alcon Acrysof) to 17.1%. The difference in Nd:YAG rates among the eight IOL designs was found to be significant (P < 0.0001, chi-square test). Comparing foldable versus rigid designs, the foldable IOLs were associated with a much lower Nd:YAG laser posterior capsulotomy rate (14.1% vs. 31.1%). CONCLUSIONS By use of the six factors regarding surgical technique and IOL choice described in this article, we strongly believe that the overall incidence of PCO and hence the incidence of Nd:YAG laser posterior capsulotomy is now rapidly decreasing from rates as high as 50% in the 1980s to early 1990s. Surgical tools and IOLs are now available to bring these rates down to single digits. Careful application and use of these tools by surgeons can genuinely lead in the direction of virtual eradication of secondary cataract, the second most common cause of visual loss worldwide.
Collapse
Affiliation(s)
- D J Apple
- Center for Research on Ocular Therapeutic and Biodevices, Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston, South Carolina 29425-2236, USA
| | | | | | | | | | | | | | | |
Collapse
|
100
|
Borovetz HS, Burke JF, Chang TMS, Colas A, Cranin AN, Curtis J, Gemmell CH, Griffith BP, Hallab NJ, Heller J, Hoffman AS, Jacobs JJ, Ideker R, Katz JL, Kennedy J, Lemons JE, Malchesky PS, Morgan JR, Padera RE, Patel AS, Reffojo MF, Roby MS, Rohr TE, Schoen FJ, Sefton MV, Sheridan RT, Smith DC, Spelman FA, Tarcha PJ, Tomapkins RG, Venugopalan R, Wagner WR, Yager P, Yarmush ML. Application of Materials in Medicine, Biology, and Artificial Organs. Biomater Sci 1996. [DOI: 10.1016/b978-012582460-6/50010-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|