51
|
Guardian MGE, Boongaling EG, Bernardo-Boongaling VRR, Gamonchuang J, Boontongto T, Burakham R, Arnnok P, Aga DS. Prevalence of per- and polyfluoroalkyl substances (PFASs) in drinking and source water from two Asian countries. CHEMOSPHERE 2020; 256:127115. [PMID: 32454354 DOI: 10.1016/j.chemosphere.2020.127115] [Citation(s) in RCA: 37] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/25/2020] [Revised: 05/14/2020] [Accepted: 05/16/2020] [Indexed: 05/06/2023]
Abstract
The present study focuses on the determination of the occurrence and levels of per- and polyfluoroalkyl substances (PFASs) in the drinking and source water from the Philippines and Thailand. A total of 46 samples (18 commercial bottled waters, 5 drinking water from vending machine (re-fill stations) and 23 source water) were analyzed using liquid chromatography with tandem high-resolution mass spectrometry. Using the targeted method, 12 different PFASs were detected in the drinking water samples with total quantifiable PFASs (∑PFASs) levels ranging from 7.16 to 59.49 ng/L; 15 PFASs were detected in source water with ∑PFASs ranging from 15.55 to 65.65 ng/L. A 100% detection frequency was observed for perfluoroheptanoic acid (PFHpA), perfluorooctanoic acid (PFOA), perfluorononanoic acid (PFNA), and perfluorosulfonic acid (PFOS) in all water samples. Six other PFASs, not included in the targeted analysis, were detected using the suspect screening approach. For the first time, the presence of 2-(N-methylperfluorooctanesulfonamido) acetic acid (N-MeFOSAA) in drinking water is reported, and 3 novel PFASs (C5H5OF8, C6H4O2F6, and C9H2O2F16) were detected using suspect screening in source water. Combined results from target and suspect screening analysis showed that PFASs detected were predominantly (52%) short-chain (with fluorinated alkyl chain of ≤6) which could be explained by their high mobility in the environment. The detected PFASs levels in drinking water will not likely pose immediate health risk to consumers according to US EPA health advisory for PFOS and PFOA of 70 ng/L, but inclusion of bottled and drinking water from re-fill stations in monitoring programs is warranted.
Collapse
Affiliation(s)
- Mary Grace E Guardian
- Department of Chemistry, University at Buffalo, The State University of New York, Buffalo, NY, 14260, United States
| | - Edison G Boongaling
- BEST Environmental Services & Testing Corp., Prime Building, Barangay Salawag, Dasmariñas, Cavite, 4114, Philippines
| | | | - Jirasak Gamonchuang
- Materials Chemistry Research Center, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen, 40002, Thailand
| | - Tittaya Boontongto
- Materials Chemistry Research Center, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen, 40002, Thailand
| | - Rodjana Burakham
- Materials Chemistry Research Center, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen, 40002, Thailand
| | - Prapha Arnnok
- Department of Chemistry, Faculty of Science, Ramkhamhaeng University, Bangkok, 10240, Thailand
| | - Diana S Aga
- Department of Chemistry, University at Buffalo, The State University of New York, Buffalo, NY, 14260, United States.
| |
Collapse
|
53
|
Challenges in the analytical determination of ultra-short-chain perfluoroalkyl acids and implications for environmental and human health. Anal Bioanal Chem 2020; 412:4785-4796. [PMID: 32399685 PMCID: PMC7334270 DOI: 10.1007/s00216-020-02692-8] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2019] [Revised: 04/17/2020] [Accepted: 04/30/2020] [Indexed: 11/23/2022]
Abstract
Ultra-short-chain perfluoroalkyl acids have recently gained attention due to increasing environmental concentrations being observed. The most well-known ultra-short-chain perfluoroalkyl acid is trifluoroacetic acid (TFA) which has been studied since the 1990s. Potential sources and the fate of ultra-short-chain perfluoroalkyl acids other than TFA are not well studied and data reporting their environmental occurrence is scarce. The analytical determination of ultra-short-chain perfluoroalkyl acids is challenging due to their high polarity resulting in low retention using reversed-phase liquid chromatography. Furthermore, recent studies have reported varying extraction recoveries in water samples depending on the water matrix and different methods have been suggested to increase the extraction recovery. The present review gives an overview of the currently used analytical methods and summarizes the findings regarding potential analytical challenges. In addition, the current state of knowledge regarding TFA and other ultra-short-chain perfluoroalkyl acids, namely perfluoropropanoic acid, trifluoromethane sulfonic acid, perfluoroethane sulfonic acid, and perfluoropropane sulfonic acid‚ are reviewed. Both known and potential sources as well as environmental concentrations are summarized and discussed together with their fate and the environmental and human implications.
Collapse
|
54
|
Wang B, Yao Y, Chen H, Chang S, Tian Y, Sun H. Per- and polyfluoroalkyl substances and the contribution of unknown precursors and short-chain (C2-C3) perfluoroalkyl carboxylic acids at solid waste disposal facilities. THE SCIENCE OF THE TOTAL ENVIRONMENT 2020; 705:135832. [PMID: 31831231 DOI: 10.1016/j.scitotenv.2019.135832] [Citation(s) in RCA: 50] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2019] [Revised: 11/27/2019] [Accepted: 11/27/2019] [Indexed: 05/06/2023]
Abstract
The emission of per- and polyfluoroalkyl substances (PFASs) from municipal solid wastes (MSW) disposal raises concerns for their potential of long-term release and risks. In this study, the occurrence of PFASs was investigated in ambient air and leachate from seven MSW disposal facilities including three landfills, two incineration plants, and two MSW transfer stations in Tianjin, China. Mass loads of PFASs (≥C4) released to the atmosphere were estimated at 0.007-0.97 kg/y/site, which were much lower than those to leachate (0.04-1.3 kg/y/site), while emission to the atmosphere at landfills was more considerable. With total oxidizable precursor (TOP) assay, unknown C4-C12 perfluoroalkyl acids (PFAAs)-precursors were found contributing 10-97 mol% in leachate and accounting for additional 15%-43% mass loads. Using IC-Ba/Ag/H cartridges, trifluoroacetic acid (C2) and perfluoropropionic acid (C3) were recovered in leachate for TOP assay (62%-78%) and determined at dominant levels of 19-81 μg/L, which accounted for mass loads of 0.08-2.6 kg/y/site. Unknown C2-C3 PFAA-precursors contributed 12-93 mol% with mass loads of 0.10-3.0 kg/y/site. Overall, unknown C2-C12 PFAA-precursors remained contributing 0.35-68 mol% in biochemically treated leachate. This study emphasizes that the profiles of unknown PFAA-precursors released during MSW disposal are to be identified, which is essential for their environmental risk assessment.
Collapse
Affiliation(s)
- Bin Wang
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, College of Environmental Science and Engineering, Nankai University, Tianjin 300350, China
| | - Yiming Yao
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, College of Environmental Science and Engineering, Nankai University, Tianjin 300350, China.
| | - Hao Chen
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, College of Environmental Science and Engineering, Nankai University, Tianjin 300350, China.
| | - Shuai Chang
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, College of Environmental Science and Engineering, Nankai University, Tianjin 300350, China
| | - Ying Tian
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, College of Environmental Science and Engineering, Nankai University, Tianjin 300350, China
| | - Hongwen Sun
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, College of Environmental Science and Engineering, Nankai University, Tianjin 300350, China.
| |
Collapse
|
55
|
Zahn D, Neuwald IJ, Knepper TP. Analysis of mobile chemicals in the aquatic environment-current capabilities, limitations and future perspectives. Anal Bioanal Chem 2020; 412:4763-4784. [PMID: 32086538 DOI: 10.1007/s00216-020-02520-z] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2019] [Revised: 02/06/2020] [Accepted: 02/13/2020] [Indexed: 01/08/2023]
Abstract
Persistent and mobile water contaminants are rapidly developing into a focal point of environmental chemistry and chemical regulation. Their defining parameter that sets them apart from the majority of regularly monitored and regulated contaminants is their mobility in the aquatic environment, which is intrinsically tied to a high polarity. This high polarity, however, may have severe implications in the analytical process and thus the most polar of these mobile contaminants may not be covered by widely utilized trace-analytical methods, and thus, alternatives are required. In this review, we infer the physical and chemical properties of mobile water contaminants from a set of almost 1800 prioritized REACH chemicals and discuss the implications these substance properties may have on four integral steps of the analytical process: sampling and sample storage, sample pre-treatment, separation and detection. We discuss alternatives to widely utilized trace-analytical methods, examine their application range and limitations, highlight potential analytical techniques on the horizon and emphasize research areas we believe still offer the most room for further improvement. While we have a comprehensive set of analytical methods to cover a large portion of the known mobile chemicals, these methods are still only infrequently utilized. Graphical abstract.
Collapse
Affiliation(s)
- Daniel Zahn
- Hochschule Fresenius gem. GmbH, Limburger Str. 2, 65510, Idstein, Germany.
| | - Isabelle J Neuwald
- Hochschule Fresenius gem. GmbH, Limburger Str. 2, 65510, Idstein, Germany
| | - Thomas P Knepper
- Hochschule Fresenius gem. GmbH, Limburger Str. 2, 65510, Idstein, Germany
| |
Collapse
|
56
|
Applicability of mixed-mode chromatography for the simultaneous analysis of C 1-C 18 perfluoroalkylated substances. Anal Bioanal Chem 2020; 412:4849-4856. [PMID: 32006062 DOI: 10.1007/s00216-020-02434-w] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2019] [Revised: 01/09/2020] [Accepted: 01/16/2020] [Indexed: 10/25/2022]
Abstract
A new analytical method for the determination of 22 perfluoroalkylated (carboxylic and sulfonic) acids in water samples is presented. The method's objective was to achieve the simultaneous quantification of compounds with different chain lengths (from C1 to C18). To this end, 500 mL of water were extracted with Oasis WAX solid-phase extraction cartridges and eluted with 3 mL of 5% ammonia in methanol. After evaporation to dryness, extracts were reconstituted in methanol:ultrapure water (1:1) and analyzed by mixed-mode liquid chromatography-tandem mass spectrometry (MMLC-MS/MS) using a weak anion exchange/reversed-phase column. The method provided good results, with limits of quantification lower than 1 ng/L in river water for most of compounds, except the two perfluorocarboxylic acids with the longest alkyl chain (>C14) and trifluoroacetic acid, for which a blank contamination problem was observed. The method proved good trueness and precision in both ultrapure and river water (R ≥ 81%, RSD ≤ 15%). After validation, the method was applied to the analysis of nine water samples where nine perfluoroalkylated acids were quantified. Seven of them were ultrashort- (C1-C4) and short-chain (C4-C8) perfluoroalkylated acids, pointing out the importance of developing methods capable to target such substances for further monitoring.
Collapse
|