51
|
Chen B, Perry D, Page A, Kang M, Unwin PR. Scanning Ion Conductance Microscopy: Quantitative Nanopipette Delivery-Substrate Electrode Collection Measurements and Mapping. Anal Chem 2019; 91:2516-2524. [PMID: 30608117 DOI: 10.1021/acs.analchem.8b05449] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Scanning ion conductance microscopy (SICM) is becoming a powerful multifunctional tool for probing and analyzing surfaces and interfaces. This work outlines methodology for the quantitative controlled delivery of ionic redox-active molecules from a nanopipette to a substrate electrode, with a high degree of spatial and temporal precision. Through control of the SICM bias applied between a quasi-reference counter electrode (QRCE) in the SICM nanopipette probe and a similar electrode in bulk solution, it is shown that ionic redox species can be held inside the nanopipette, and then pulse-delivered to a defined region of a substrate positioned beneath the nanopipette. A self-referencing hopping mode imaging protocol is implemented, where reagent is released in bulk solution (reference measurement) and near the substrate surface at each pixel in an image, with the tip and substrate currents measured throughout. Analysis of the tip and substrate current data provides an improved understanding of mass transport and nanoscale delivery in SICM and a new means of synchronously mapping electrode reactivity, surface topography, and charge. Experiments on Ru(NH3)63+ reduction to Ru(NH3)62+ and dopamine oxidation in aqueous solution at a carbon fiber ultramicroelectrode (UME), used as the substrate, illustrate these aspects. Finite element method (FEM) modeling provides quantitative understanding of molecular delivery in SICM. The approach outlined constitutes a new methodology for electrode mapping and provides improved insights on the use of SICM for controlled delivery to interfaces generally.
Collapse
|
52
|
Tao L, Qiao M, Jin R, Li Y, Xiao Z, Wang Y, Zhang N, Xie C, He Q, Jiang D, Yu G, Li Y, Wang S. Bridging the Surface Charge and Catalytic Activity of a Defective Carbon Electrocatalyst. Angew Chem Int Ed Engl 2019. [DOI: 10.1002/ange.201810207] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Affiliation(s)
- Li Tao
- State Key Laboratory of Chemo/Bio-Sensing and ChemometricsProvincial Hunan Key Laboratory for Graphene Materials and DevicesCollege of Chemistry and Chemical EngineeringHunan University Changsha 410082 P. R. China
| | - Man Qiao
- School of Chemistry and Materials ScienceNanjing Normal University Nanjing 210023 China
| | - Rong Jin
- School of Chemistry and Chemical EngineeringNanjing University Nanjing Jiangsu 210093 China
| | - Yan Li
- College of Chemical and Biological EngineeringZhejiang University Hangzhou 310027 China
| | - Zhaohui Xiao
- State Key Laboratory of Chemo/Bio-Sensing and ChemometricsProvincial Hunan Key Laboratory for Graphene Materials and DevicesCollege of Chemistry and Chemical EngineeringHunan University Changsha 410082 P. R. China
| | - Yuqing Wang
- State Key Laboratory of Chemo/Bio-Sensing and ChemometricsProvincial Hunan Key Laboratory for Graphene Materials and DevicesCollege of Chemistry and Chemical EngineeringHunan University Changsha 410082 P. R. China
| | - Nana Zhang
- State Key Laboratory of Chemo/Bio-Sensing and ChemometricsProvincial Hunan Key Laboratory for Graphene Materials and DevicesCollege of Chemistry and Chemical EngineeringHunan University Changsha 410082 P. R. China
| | - Chao Xie
- State Key Laboratory of Chemo/Bio-Sensing and ChemometricsProvincial Hunan Key Laboratory for Graphene Materials and DevicesCollege of Chemistry and Chemical EngineeringHunan University Changsha 410082 P. R. China
| | - Qinggang He
- College of Chemical and Biological EngineeringZhejiang University Hangzhou 310027 China
| | - Dechen Jiang
- School of Chemistry and Chemical EngineeringNanjing University Nanjing Jiangsu 210093 China
| | - Gang Yu
- State Key Laboratory of Chemo/Bio-Sensing and ChemometricsProvincial Hunan Key Laboratory for Graphene Materials and DevicesCollege of Chemistry and Chemical EngineeringHunan University Changsha 410082 P. R. China
| | - Yafei Li
- School of Chemistry and Materials ScienceNanjing Normal University Nanjing 210023 China
| | - Shuangyin Wang
- State Key Laboratory of Chemo/Bio-Sensing and ChemometricsProvincial Hunan Key Laboratory for Graphene Materials and DevicesCollege of Chemistry and Chemical EngineeringHunan University Changsha 410082 P. R. China
| |
Collapse
|
53
|
Bentley CL, Edmondson J, Meloni GN, Perry D, Shkirskiy V, Unwin PR. Nanoscale Electrochemical Mapping. Anal Chem 2018; 91:84-108. [PMID: 30500157 DOI: 10.1021/acs.analchem.8b05235] [Citation(s) in RCA: 94] [Impact Index Per Article: 13.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
54
|
Neves MMPDS, Martín-Yerga D. Advanced Nanoscale Approaches to Single-(Bio)entity Sensing and Imaging. BIOSENSORS 2018; 8:E100. [PMID: 30373209 PMCID: PMC6316691 DOI: 10.3390/bios8040100] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/15/2018] [Revised: 10/11/2018] [Accepted: 10/23/2018] [Indexed: 01/01/2023]
Abstract
Individual (bio)chemical entities could show a very heterogeneous behaviour under the same conditions that could be relevant in many biological processes of significance in the life sciences. Conventional detection approaches are only able to detect the average response of an ensemble of entities and assume that all entities are identical. From this perspective, important information about the heterogeneities or rare (stochastic) events happening in individual entities would remain unseen. Some nanoscale tools present interesting physicochemical properties that enable the possibility to detect systems at the single-entity level, acquiring richer information than conventional methods. In this review, we introduce the foundations and the latest advances of several nanoscale approaches to sensing and imaging individual (bio)entities using nanoprobes, nanopores, nanoimpacts, nanoplasmonics and nanomachines. Several (bio)entities such as cells, proteins, nucleic acids, vesicles and viruses are specifically considered. These nanoscale approaches provide a wide and complete toolbox for the study of many biological systems at the single-entity level.
Collapse
Affiliation(s)
| | - Daniel Martín-Yerga
- Department of Chemical Engineering, KTH Royal Institute of Technology, 100-44 Stockholm, Sweden.
| |
Collapse
|
55
|
Conzuelo F, Schulte A, Schuhmann W. Biological imaging with scanning electrochemical microscopy. Proc Math Phys Eng Sci 2018; 474:20180409. [PMID: 30839832 PMCID: PMC6237495 DOI: 10.1098/rspa.2018.0409] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2018] [Accepted: 09/04/2018] [Indexed: 12/27/2022] Open
Abstract
Scanning electrochemical microscopy (SECM) is a powerful and versatile technique for visualizing the local electrochemical activity of a surface as an ultramicroelectrode tip is moved towards or over a sample of interest using precise positioning systems. In comparison with other scanning probe techniques, SECM not only enables topographical surface mapping but also gathers chemical information with high spatial resolution. Considerable progress has been made in the analysis of biological samples, including living cells and immobilized biomacromolecules such as enzymes, antibodies and DNA fragments. Moreover, combinations of SECM with comple-mentary analytical tools broadened its applicability and facilitated multi-functional analysis with extended life science capabilities. The aim of this review is to present a brief topical overview on recent applications of biological SECM, with particular emphasis on important technical improvements of this surface imaging technique, recommended applications and future trends.
Collapse
Affiliation(s)
- Felipe Conzuelo
- Analytical Chemistry—Center for Electrochemical Sciences (CES), Faculty for Chemistry and Biochemistry, Ruhr-Universität Bochum, Universitätsstr. 150, 44780 Bochum, Germany
| | - Albert Schulte
- School of Biomolecular Science and Engineering (BSE), Vidyasirimedhi Institute of Science and Technology (VISTEC), Rayong 21210, Thailand
| | - Wolfgang Schuhmann
- Analytical Chemistry—Center for Electrochemical Sciences (CES), Faculty for Chemistry and Biochemistry, Ruhr-Universität Bochum, Universitätsstr. 150, 44780 Bochum, Germany
| |
Collapse
|
56
|
Dorwling-Carter L, Aramesh M, Han H, Zambelli T, Momotenko D. Combined Ion Conductance and Atomic Force Microscope for Fast Simultaneous Topographical and Surface Charge Imaging. Anal Chem 2018; 90:11453-11460. [DOI: 10.1021/acs.analchem.8b02569] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Affiliation(s)
- Livie Dorwling-Carter
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, ETH Zurich, Zurich CH-8092, Switzerland
| | - Morteza Aramesh
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, ETH Zurich, Zurich CH-8092, Switzerland
| | - Hana Han
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, ETH Zurich, Zurich CH-8092, Switzerland
| | - Tomaso Zambelli
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, ETH Zurich, Zurich CH-8092, Switzerland
| | - Dmitry Momotenko
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, ETH Zurich, Zurich CH-8092, Switzerland
| |
Collapse
|
57
|
Mapping Surface Charge of Individual Microdomains with Scanning Ion Conductance Microscopy. ChemElectroChem 2018. [DOI: 10.1002/celc.201800724] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
|
58
|
Saha-Shah A, Karty JA, Baker LA. Local collection, reaction and analysis with theta pipette emitters. Analyst 2018; 142:1512-1518. [PMID: 28361146 DOI: 10.1039/c7an00109f] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
A mobile nanofluidic device based on theta pipettes was developed for "collect-react-analyze" measurements of small volumes of a sample collected locally from biological samples. Specifically, we demonstrate execution of local reactions inside single cells and on Pseudomonas aeruginosa biofilms for targeted analysis of metabolites. Nanoliter volumes of the sample, post-reaction, were delivered to a mass spectrometer via electrospray ionization (ESI) for chemical analysis. A new strategy was developed where the additional barrel of a theta pipette was utilized both to enable chemical manipulations after sample collection and to electrospray the nanoliter sample volumes collected directly from the pipette tip. This strategy proved a robust method for ESI from nanometer sized tips without clogging or degradation of the emitter and obviated the need to coat glass pipettes with a conductive metal coating. Chemical reactions investigated include acid catalyzed degradation of oligosaccharides inside the pipette tip to increase the detection sensitivity of minor metabolites found in Allium cepa cells. Additionally, phenylboronic acid complexation of carbohydrates from single cells and liposaccharides from biofilms was also performed inside the pipette tip for selective detection of carbohydrates and liposaccharides with cis-diols.
Collapse
Affiliation(s)
- Anumita Saha-Shah
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, USA.
| | | | | |
Collapse
|
59
|
Hagemann P, Gesper A, Happel P. Correlative Stimulated Emission Depletion and Scanning Ion Conductance Microscopy. ACS NANO 2018; 12:5807-5815. [PMID: 29791140 DOI: 10.1021/acsnano.8b01731] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Correlation microscopy combining fluorescence and scanning probe or electron microscopy is limited to fixed samples due to the sample preparation and nonphysiological imaging conditions required by most probe or electron microscopy techniques. Among the few scanning probe techniques that allow imaging of living cells under physiological conditions, scanning ion conductance microscopy (SICM) has been shown to be the technique that minimizes the impact on the investigated sample. However, combinations of SICM and fluorescence microscopy suffered from the mismatch in resolution due to the limited resolution of conventional light microscopy. In the last years, the diffraction limit of light microscopy has been circumvented by various techniques, one of which is stimulated emission depletion (STED) microscopy. Here, we aimed at demonstrating the combination of STED and SICM. We show that both methods allow recording a living cellular specimen and provide a SICM and STED image of the same sample, which allowed us to correlate the membrane surface topography and the distribution of the cytoskeletal protein actin. Our proof-of-concept study exemplifies the benefit of correlating SICM with a subdiffraction fluorescence method and might form the basis for the development of a combined instrument that would allow the simultaneous recording of subdiffraction fluorescence and topography information.
Collapse
Affiliation(s)
- Philipp Hagemann
- Nanoscopy Group, RUBION , Ruhr-Universität Bochum , Universitätsstraße 150 , D-44801 , Bochum , Germany
| | - Astrid Gesper
- Nanoscopy Group, RUBION , Ruhr-Universität Bochum , Universitätsstraße 150 , D-44801 , Bochum , Germany
| | - Patrick Happel
- Nanoscopy Group, RUBION , Ruhr-Universität Bochum , Universitätsstraße 150 , D-44801 , Bochum , Germany
| |
Collapse
|
60
|
Zhang S, Li M, Su B, Shao Y. Fabrication and Use of Nanopipettes in Chemical Analysis. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2018; 11:265-286. [PMID: 29894227 DOI: 10.1146/annurev-anchem-061417-125840] [Citation(s) in RCA: 47] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
This review summarizes progress in the fabrication, modification, characterization, and applications of nanopipettes since 2010. A brief history of nanopipettes is introduced, and the details of fabrication, modification, and characterization of nanopipettes are provided. Applications of nanopipettes in chemical analysis are the focus in several cases, including recent progress in imaging; in the study of single molecules, single nanoparticles, and single cells; in fundamental investigations of charge transfer (ion and electron) reactions at liquid/liquid interfaces; and as hyphenated techniques combined with other methods to study the mechanisms of complicated electrochemical reactions and to conduct bioanalysis.
Collapse
Affiliation(s)
- Shudong Zhang
- Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, China;
| | - Mingzhi Li
- Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, China;
| | - Bin Su
- Institute of Analytical Chemistry, Department of Chemistry, Zhejiang University, Hangzhou 310058, China;
| | - Yuanhua Shao
- Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, China;
| |
Collapse
|
61
|
Lin TE, Rapino S, Girault HH, Lesch A. Electrochemical imaging of cells and tissues. Chem Sci 2018; 9:4546-4554. [PMID: 29899947 PMCID: PMC5969511 DOI: 10.1039/c8sc01035h] [Citation(s) in RCA: 60] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2018] [Accepted: 04/09/2018] [Indexed: 01/10/2023] Open
Abstract
This minireview summarizes the recent achievements of electrochemical imaging platforms to map cellular functions in biological specimens using electrochemical scanning nano/micro-probe microscopy and 2D chips containing microelectrode arrays.
The technological and experimental progress in electrochemical imaging of biological specimens is discussed with a view on potential applications for skin cancer diagnostics, reproductive medicine and microbial testing. The electrochemical analysis of single cell activity inside cell cultures, 3D cellular aggregates and microtissues is based on the selective detection of electroactive species involved in biological functions. Electrochemical imaging strategies, based on nano/micrometric probes scanning over the sample and sensor array chips, respectively, can be made sensitive and selective without being affected by optical interference as many other microscopy techniques. The recent developments in microfabrication, electronics and cell culturing/tissue engineering have evolved in affordable and fast-sampling electrochemical imaging platforms. We believe that the topics discussed herein demonstrate the applicability of electrochemical imaging devices in many areas related to cellular functions.
Collapse
Affiliation(s)
- Tzu-En Lin
- Laboratory of Physical and Analytical Electrochemistry (LEPA) , École Polytechnique Fédéderale de Lausanne , EPFL Valais Valais , Rue de l'Industrie 17 , CP 440 , 1951 Sion , Switzerland .
| | - Stefania Rapino
- Chemistry Department "Giacomo Ciamician" , University of Bologna , Via Selmi 2 , 40126 Bologna , Italy
| | - Hubert H Girault
- Laboratory of Physical and Analytical Electrochemistry (LEPA) , École Polytechnique Fédéderale de Lausanne , EPFL Valais Valais , Rue de l'Industrie 17 , CP 440 , 1951 Sion , Switzerland .
| | - Andreas Lesch
- Laboratory of Physical and Analytical Electrochemistry (LEPA) , École Polytechnique Fédéderale de Lausanne , EPFL Valais Valais , Rue de l'Industrie 17 , CP 440 , 1951 Sion , Switzerland .
| |
Collapse
|
62
|
He X, Zhang K, Liu Y, Wu F, Yu P, Mao L. Chaotropic Monovalent Anion‐Induced Rectification Inversion at Nanopipettes Modified by Polyimidazolium Brushes. Angew Chem Int Ed Engl 2018; 57:4590-4593. [DOI: 10.1002/anie.201800335] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2018] [Revised: 02/09/2018] [Indexed: 11/07/2022]
Affiliation(s)
- Xiulan He
- Beijing National Laboratory for Molecular Sciences Key Laboratory of Analytical Chemistry for Living Biosystems Institute of Chemistry the Chinese Academy of Sciences (CAS) Beijing 100190 China
- University of Chinese Academy of Sciences Beijing 100049 China
| | - Kailin Zhang
- Beijing National Laboratory for Molecular Sciences Key Laboratory of Analytical Chemistry for Living Biosystems Institute of Chemistry the Chinese Academy of Sciences (CAS) Beijing 100190 China
- University of Chinese Academy of Sciences Beijing 100049 China
| | - Yang Liu
- Beijing National Laboratory for Molecular Sciences Key Laboratory of Analytical Chemistry for Living Biosystems Institute of Chemistry the Chinese Academy of Sciences (CAS) Beijing 100190 China
| | - Fei Wu
- Beijing National Laboratory for Molecular Sciences Key Laboratory of Analytical Chemistry for Living Biosystems Institute of Chemistry the Chinese Academy of Sciences (CAS) Beijing 100190 China
| | - Ping Yu
- Beijing National Laboratory for Molecular Sciences Key Laboratory of Analytical Chemistry for Living Biosystems Institute of Chemistry the Chinese Academy of Sciences (CAS) Beijing 100190 China
- University of Chinese Academy of Sciences Beijing 100049 China
| | - Lanqun Mao
- Beijing National Laboratory for Molecular Sciences Key Laboratory of Analytical Chemistry for Living Biosystems Institute of Chemistry the Chinese Academy of Sciences (CAS) Beijing 100190 China
- University of Chinese Academy of Sciences Beijing 100049 China
| |
Collapse
|
63
|
He X, Zhang K, Liu Y, Wu F, Yu P, Mao L. Chaotropic Monovalent Anion‐Induced Rectification Inversion at Nanopipettes Modified by Polyimidazolium Brushes. Angew Chem Int Ed Engl 2018. [DOI: 10.1002/ange.201800335] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Affiliation(s)
- Xiulan He
- Beijing National Laboratory for Molecular Sciences Key Laboratory of Analytical Chemistry for Living Biosystems Institute of Chemistry the Chinese Academy of Sciences (CAS) Beijing 100190 China
- University of Chinese Academy of Sciences Beijing 100049 China
| | - Kailin Zhang
- Beijing National Laboratory for Molecular Sciences Key Laboratory of Analytical Chemistry for Living Biosystems Institute of Chemistry the Chinese Academy of Sciences (CAS) Beijing 100190 China
- University of Chinese Academy of Sciences Beijing 100049 China
| | - Yang Liu
- Beijing National Laboratory for Molecular Sciences Key Laboratory of Analytical Chemistry for Living Biosystems Institute of Chemistry the Chinese Academy of Sciences (CAS) Beijing 100190 China
| | - Fei Wu
- Beijing National Laboratory for Molecular Sciences Key Laboratory of Analytical Chemistry for Living Biosystems Institute of Chemistry the Chinese Academy of Sciences (CAS) Beijing 100190 China
| | - Ping Yu
- Beijing National Laboratory for Molecular Sciences Key Laboratory of Analytical Chemistry for Living Biosystems Institute of Chemistry the Chinese Academy of Sciences (CAS) Beijing 100190 China
- University of Chinese Academy of Sciences Beijing 100049 China
| | - Lanqun Mao
- Beijing National Laboratory for Molecular Sciences Key Laboratory of Analytical Chemistry for Living Biosystems Institute of Chemistry the Chinese Academy of Sciences (CAS) Beijing 100190 China
- University of Chinese Academy of Sciences Beijing 100049 China
| |
Collapse
|
64
|
Zhang J, Zhou J, Pan R, Jiang D, Burgess JD, Chen HY. New Frontiers and Challenges for Single-Cell Electrochemical Analysis. ACS Sens 2018; 3:242-250. [PMID: 29276834 DOI: 10.1021/acssensors.7b00711] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Previous measurements of cell populations might obscure many important cellular differences, and new strategies for single-cell analyses are urgently needed to re-examine these fundamental biological principles for better diagnosis and treatment of diseases. Electrochemistry is a robust technique for the analysis of single living cells that has the advantages of minor interruption of cellular activity and provides the capability of high spatiotemporal resolution. The achievements of the past 30 years have revealed significant information about the exocytotic events of single cells to elucidate the mechanisms of cellular activity. Currently, the rapid developments of micro/nanofabrication and optoelectronic technologies drive the development of multifunctional electrodes and novel electrochemical approaches with higher resolution for single cells. In this Perspective, three new frontiers in this field, namely, electrochemical microscopy, intracellular analysis, and single-cell analysis in a biological system (i.e., neocortex and retina), are reviewed. The unique features and remaining challenges of these techniques are discussed.
Collapse
Affiliation(s)
- Jingjing Zhang
- The
State Key Laboratory of Analytical Chemistry for Life Science, School
of Chemistry and Chemical Engineering, Nanjing University, Jiangsu 210093, China
| | - Junyu Zhou
- The
State Key Laboratory of Analytical Chemistry for Life Science, School
of Chemistry and Chemical Engineering, Nanjing University, Jiangsu 210093, China
| | - Rongrong Pan
- The
State Key Laboratory of Analytical Chemistry for Life Science, School
of Chemistry and Chemical Engineering, Nanjing University, Jiangsu 210093, China
| | - Dechen Jiang
- The
State Key Laboratory of Analytical Chemistry for Life Science, School
of Chemistry and Chemical Engineering, Nanjing University, Jiangsu 210093, China
| | - James D. Burgess
- Department
of Medical Laboratory, Imaging, and Radiologic Sciences, College of
Allied Health Sciences, Augusta University, Augusta, Georgia 30912, United States
| | - Hong-Yuan Chen
- The
State Key Laboratory of Analytical Chemistry for Life Science, School
of Chemistry and Chemical Engineering, Nanjing University, Jiangsu 210093, China
| |
Collapse
|
65
|
Takahashi Y, Ida H, Matsumae Y, Komaki H, Zhou Y, Kumatani A, Kanzaki M, Shiku H, Matsue T. 3D electrochemical and ion current imaging using scanning electrochemical-scanning ion conductance microscopy. Phys Chem Chem Phys 2018; 19:26728-26733. [PMID: 28951914 DOI: 10.1039/c7cp05157c] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Local cell-membrane permeability and ionic strength are important factors for maintaining the functions of cells. Here, we measured the spatial electrochemical and ion concentration profile near the sample surface with nanoscale resolution using scanning electrochemical microscopy (SECM) combined with scanning ion-conductance microscopy (SICM). The ion current feedback system is an effective way to control probe-sample distance without contact and monitor the kinetic effect of mediator regeneration and the chemical concentration profile. For demonstrating 3D electrochemical and ion concentration mapping, we evaluated the reaction rate of electrochemical mediator regeneration on an unbiased conductor and visualized inhomogeneous permeability and the ion concentration 3D profile on a single fixed adipocyte cell surface.
Collapse
Affiliation(s)
- Yasufumi Takahashi
- WPI-Advanced Institute for Materials Research, Tohoku University, 980-8577, Japan.
| | | | | | | | | | | | | | | | | |
Collapse
|
66
|
Wang ZY, Zhang P, Ma Z. On the physics of both surface overcharging and charge reversal at heterophase interfaces. Phys Chem Chem Phys 2018; 20:4118-4128. [DOI: 10.1039/c7cp08117k] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
A series of Monte Carlo simulations are employed to reveal the physics of both surface overcharging and charge reversal at a negatively charged dielectric interface exposed to a bulk solution containing a +2:−1 electrolyte in the absence and presence of a monovalent salt.
Collapse
Affiliation(s)
- Zhi-Yong Wang
- School of Science
- Chongqing University of Technology
- Chongqing 400054
- China
| | - Pengli Zhang
- School of Science
- Chongqing University of Technology
- Chongqing 400054
- China
| | - Zengwei Ma
- School of Science
- Chongqing University of Technology
- Chongqing 400054
- China
| |
Collapse
|
67
|
Abstract
Understanding ion transport properties at various interfaces, especially at small length scales, is critical in advancing our knowledge of membrane materials and cell biology. Recently, we described potentiometric-scanning ion conductance microscopy (P-SICM) for ion-conductance measurement in polymer membranes and epithelial cell monolayers at discrete points in a sample. Here, we combine hopping mode techniques with P-SICM to allow simultaneous nanometer-scale conductance and topography mapping. First validated with standard synthetic membranes and then demonstrated in living epithelial cell monolayers under physiological conditions, this new method allows direct visualization of heterogeneous ion transport of biological samples for the first time. These advances provide a noncontact local probe, require no labeling, and present a new tool for quantifying intrinsic transport properties of a variety of biological samples.
Collapse
Affiliation(s)
- Lushan Zhou
- Department of Chemistry, Indiana University , 800 East Kirkwood Avenue, Bloomington, Indiana 47405, United States
| | | | | | - Lane A Baker
- Department of Chemistry, Indiana University , 800 East Kirkwood Avenue, Bloomington, Indiana 47405, United States
| |
Collapse
|
68
|
Perry D, Page A, Chen B, Frenguelli BG, Unwin PR. Differential-Concentration Scanning Ion Conductance Microscopy. Anal Chem 2017; 89:12458-12465. [DOI: 10.1021/acs.analchem.7b03543] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Affiliation(s)
- David Perry
- Department
of Chemistry, ‡MOAC Doctoral Training Centre, §School of Life Sciences, University of Warwick, Coventry, CV4 7AL, United Kingdom
| | - Ashley Page
- Department
of Chemistry, ‡MOAC Doctoral Training Centre, §School of Life Sciences, University of Warwick, Coventry, CV4 7AL, United Kingdom
| | - Baoping Chen
- Department
of Chemistry, ‡MOAC Doctoral Training Centre, §School of Life Sciences, University of Warwick, Coventry, CV4 7AL, United Kingdom
| | - Bruno G. Frenguelli
- Department
of Chemistry, ‡MOAC Doctoral Training Centre, §School of Life Sciences, University of Warwick, Coventry, CV4 7AL, United Kingdom
| | - Patrick R. Unwin
- Department
of Chemistry, ‡MOAC Doctoral Training Centre, §School of Life Sciences, University of Warwick, Coventry, CV4 7AL, United Kingdom
| |
Collapse
|
69
|
Kang M, Perry D, Bentley CL, West G, Page A, Unwin PR. Simultaneous Topography and Reaction Flux Mapping at and around Electrocatalytic Nanoparticles. ACS NANO 2017; 11:9525-9535. [PMID: 28862831 DOI: 10.1021/acsnano.7b05435] [Citation(s) in RCA: 43] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The characterization of electrocatalytic reactions at individual nanoparticles (NPs) is presently of considerable interest but very challenging. Herein, we demonstrate how simple-to-fabricate nanopipette probes with diameters of approximately 30 nm can be deployed in a scanning ion conductance microscopy (SICM) platform to simultaneously visualize electrochemical reactivity and topography with high spatial resolution at electrochemical interfaces. By employing a self-referencing hopping mode protocol, whereby the probe is brought from bulk solution to the near-surface at each pixel, and with potential-time control applied at the substrate, current measurements at the nanopipette can be made with high precision and resolution (30 nm resolution, 2600 pixels μm-2, <0.3 s pixel-1) to reveal a wealth of information on the substrate physicochemical properties. This methodology has been applied to image the electrocatalytic oxidation of borohydride at ensembles of AuNPs on a carbon fiber support in alkaline media, whereby the depletion of hydroxide ions and release of water during the reaction results in a detectable change in the ionic composition around the NPs. Through the use of finite element method simulations, these observations are validated and analyzed to reveal important information on heterogeneities in ion flux between the top of a NP and the gap at the NP-support contact, diffusional overlap and competition for reactant between neighboring NPs, and differences in NP activity. These studies highlight key issues that influence the behavior of NP assemblies at the single NP level and provide a platform for the use of SICM as an important tool for electrocatalysis studies.
Collapse
Affiliation(s)
- Minkyung Kang
- Department of Chemistry, ‡Warwick Manufacturing Group, and §MOAC Doctoral Training Centre, University of Warwick , Coventry CV4 7AL, United Kingdom
| | - David Perry
- Department of Chemistry, ‡Warwick Manufacturing Group, and §MOAC Doctoral Training Centre, University of Warwick , Coventry CV4 7AL, United Kingdom
| | - Cameron L Bentley
- Department of Chemistry, ‡Warwick Manufacturing Group, and §MOAC Doctoral Training Centre, University of Warwick , Coventry CV4 7AL, United Kingdom
| | - Geoff West
- Department of Chemistry, ‡Warwick Manufacturing Group, and §MOAC Doctoral Training Centre, University of Warwick , Coventry CV4 7AL, United Kingdom
| | - Ashley Page
- Department of Chemistry, ‡Warwick Manufacturing Group, and §MOAC Doctoral Training Centre, University of Warwick , Coventry CV4 7AL, United Kingdom
| | - Patrick R Unwin
- Department of Chemistry, ‡Warwick Manufacturing Group, and §MOAC Doctoral Training Centre, University of Warwick , Coventry CV4 7AL, United Kingdom
| |
Collapse
|
70
|
Meloni GN. 3D Printed and Microcontrolled: The One Hundred Dollars Scanning Electrochemical Microscope. Anal Chem 2017; 89:8643-8649. [PMID: 28741350 DOI: 10.1021/acs.analchem.7b01764] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
The design and fabrication of a versatile and low-cost electrochemical-scanning probe microscope (EC-SPM) is presented. The proposed equipment relies on the use of modern prototyping tools such as 3D printers and microcontroller boards and only a few "off-the-shelf" parts to deliver a simple yet powerful EC-SPM equipment capable of performing simple space-resolved electrochemical measurements. The equipment was able to perform space-resolved electrochemical measurements using a platinum ultramicroelectrode (UME) as the working electrode on a scanning electrochemical microscopy (SECM) configuration and was used to record approach curves, line scans, and array scans over an insulating substrate. The performance of the proposed equipment was found to be adequate for simple SECM measurements under hindered diffusion conditions. Because of its flexible design (software and hardware), more complex array scan patterns, only found on high-end EC-SPM setups such as hopping mode scan, were easily implemented on the built equipment. Despite its simplicity, the versatility and low cost of the proposed design make it an attractive alternative as a teaching platform as well as a platform for developing more elaborate EC-SPM setups.
Collapse
Affiliation(s)
- Gabriel N Meloni
- Instituto de Química Universidade de São Paulo , Av. Profesor Lineu Prestes, 748, São Paulo, São Paulo, Brazil 05508-000
| |
Collapse
|
71
|
Page A, Perry D, Unwin PR. Multifunctional scanning ion conductance microscopy. Proc Math Phys Eng Sci 2017; 473:20160889. [PMID: 28484332 PMCID: PMC5415692 DOI: 10.1098/rspa.2016.0889] [Citation(s) in RCA: 57] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2016] [Accepted: 03/13/2017] [Indexed: 12/21/2022] Open
Abstract
Scanning ion conductance microscopy (SICM) is a nanopipette-based technique that has traditionally been used to image topography or to deliver species to an interface, particularly in a biological setting. This article highlights the recent blossoming of SICM into a technique with a much greater diversity of applications and capability that can be used either standalone, with advanced control (potential-time) functions, or in tandem with other methods. SICM can be used to elucidate functional information about interfaces, such as surface charge density or electrochemical activity (ion fluxes). Using a multi-barrel probe format, SICM-related techniques can be employed to deposit nanoscale three-dimensional structures and further functionality is realized when SICM is combined with scanning electrochemical microscopy (SECM), with simultaneous measurements from a single probe opening up considerable prospects for multifunctional imaging. SICM studies are greatly enhanced by finite-element method modelling for quantitative treatment of issues such as resolution, surface charge and (tip) geometry effects. SICM is particularly applicable to the study of living systems, notably single cells, although applications extend to materials characterization and to new methods of printing and nanofabrication. A more thorough understanding of the electrochemical principles and properties of SICM provides a foundation for significant applications of SICM in electrochemistry and interfacial science.
Collapse
Affiliation(s)
- Ashley Page
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, UK
- MOAC Doctoral Training Centre, University of Warwick, Coventry CV4 7AL, UK
| | - David Perry
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, UK
- MOAC Doctoral Training Centre, University of Warwick, Coventry CV4 7AL, UK
| | - Patrick R. Unwin
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, UK
| |
Collapse
|
72
|
Page A, Kang M, Armitstead A, Perry D, Unwin PR. Quantitative Visualization of Molecular Delivery and Uptake at Living Cells with Self-Referencing Scanning Ion Conductance Microscopy-Scanning Electrochemical Microscopy. Anal Chem 2017; 89:3021-3028. [DOI: 10.1021/acs.analchem.6b04629] [Citation(s) in RCA: 57] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
- Ashley Page
- Department of Chemistry and ‡MOAC Doctoral
Training Centre, University of Warwick, Coventry, CV4 7AL, United Kingdom
| | - Minkyung Kang
- Department of Chemistry and ‡MOAC Doctoral
Training Centre, University of Warwick, Coventry, CV4 7AL, United Kingdom
| | - Alexander Armitstead
- Department of Chemistry and ‡MOAC Doctoral
Training Centre, University of Warwick, Coventry, CV4 7AL, United Kingdom
| | - David Perry
- Department of Chemistry and ‡MOAC Doctoral
Training Centre, University of Warwick, Coventry, CV4 7AL, United Kingdom
| | - Patrick R. Unwin
- Department of Chemistry and ‡MOAC Doctoral
Training Centre, University of Warwick, Coventry, CV4 7AL, United Kingdom
| |
Collapse
|
73
|
Affiliation(s)
- Wenqing Shi
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, United States
| | - Alicia K. Friedman
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, United States
| | - Lane A. Baker
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, United States
| |
Collapse
|
74
|
Takahashi Y, Kumatani A, Shiku H, Matsue T. Scanning Probe Microscopy for Nanoscale Electrochemical Imaging. Anal Chem 2016; 89:342-357. [DOI: 10.1021/acs.analchem.6b04355] [Citation(s) in RCA: 78] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Yasufumi Takahashi
- Division
of Electrical Engineering and Computer Science, Kanazawa University, Kanazawa 920-1192, Japan
- Precursory
Research for Embryonic Science and Technology (PRESTO), Japan Science and Technology Agency (JST), Saitama 332-0012, Japan
| | - Akichika Kumatani
- Advanced
Institute for Materials Research, Tohoku University, Sendai 980-8577, Japan
- Graduate
School of Environmental Studies, Tohoku University, Sendai 980-8579, Japan
| | - Hitoshi Shiku
- Department
of Applied Chemistry, Graduate School of Engineering, Tohoku University, Sendai 980-8579, Japan
| | - Tomokazu Matsue
- Advanced
Institute for Materials Research, Tohoku University, Sendai 980-8577, Japan
- Graduate
School of Environmental Studies, Tohoku University, Sendai 980-8579, Japan
| |
Collapse
|
75
|
Continuous collection and simultaneous detection of picoliter volume of nucleic acid samples using a mille-feuille probe. Anal Bioanal Chem 2016; 409:961-969. [DOI: 10.1007/s00216-016-0006-y] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2016] [Revised: 09/20/2016] [Accepted: 10/04/2016] [Indexed: 01/12/2023]
|
76
|
Meloni GN, Bertotti M. Ring-disc Microelectrodes towards Glutathione Electrochemical Detection. ELECTROANAL 2016. [DOI: 10.1002/elan.201600574] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Gabriel N. Meloni
- Department of Fundamental Chemistry; Institute of Chemistry; University of São Paulo; Av. Prof. Lineu Prestes, 748 05508-000 São Paulo, SP Brazil
| | - Mauro Bertotti
- Department of Fundamental Chemistry; Institute of Chemistry; University of São Paulo; Av. Prof. Lineu Prestes, 748 05508-000 São Paulo, SP Brazil
| |
Collapse
|
77
|
Page A, Perry D, Young P, Mitchell D, Frenguelli BG, Unwin PR. Fast Nanoscale Surface Charge Mapping with Pulsed-Potential Scanning Ion Conductance Microscopy. Anal Chem 2016; 88:10854-10859. [DOI: 10.1021/acs.analchem.6b03744] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Affiliation(s)
- Ashley Page
- Department of Chemistry, ‡MOAC Doctoral Training Centre, §School of Life Sciences, and ∥Warwick Medical
School, University of Warwick, Coventry, CV4 7AL, United Kingdom
| | - David Perry
- Department of Chemistry, ‡MOAC Doctoral Training Centre, §School of Life Sciences, and ∥Warwick Medical
School, University of Warwick, Coventry, CV4 7AL, United Kingdom
| | - Philip Young
- Department of Chemistry, ‡MOAC Doctoral Training Centre, §School of Life Sciences, and ∥Warwick Medical
School, University of Warwick, Coventry, CV4 7AL, United Kingdom
| | - Daniel Mitchell
- Department of Chemistry, ‡MOAC Doctoral Training Centre, §School of Life Sciences, and ∥Warwick Medical
School, University of Warwick, Coventry, CV4 7AL, United Kingdom
| | - Bruno G. Frenguelli
- Department of Chemistry, ‡MOAC Doctoral Training Centre, §School of Life Sciences, and ∥Warwick Medical
School, University of Warwick, Coventry, CV4 7AL, United Kingdom
| | - Patrick R. Unwin
- Department of Chemistry, ‡MOAC Doctoral Training Centre, §School of Life Sciences, and ∥Warwick Medical
School, University of Warwick, Coventry, CV4 7AL, United Kingdom
| |
Collapse
|
78
|
Perry D, Parker AS, Page A, Unwin PR. Electrochemical Control of Calcium Carbonate Crystallization and Dissolution in Nanopipettes. ChemElectroChem 2016. [DOI: 10.1002/celc.201600547] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- David Perry
- Department of Chemistry; University of Warwick; Gibbet Hill Road Coventry CV4 7AL UK
- MOAC Doctoral Training Centre; University of Warwick; Gibbet Hill Road Coventry CV4 7AL UK
| | - Alexander S. Parker
- Department of Chemistry; University of Warwick; Gibbet Hill Road Coventry CV4 7AL UK
| | - Ashley Page
- Department of Chemistry; University of Warwick; Gibbet Hill Road Coventry CV4 7AL UK
- MOAC Doctoral Training Centre; University of Warwick; Gibbet Hill Road Coventry CV4 7AL UK
| | - Patrick R. Unwin
- Department of Chemistry; University of Warwick; Gibbet Hill Road Coventry CV4 7AL UK
| |
Collapse
|
79
|
Momotenko D, Page A, Adobes-Vidal M, Unwin PR. Write-Read 3D Patterning with a Dual-Channel Nanopipette. ACS NANO 2016; 10:8871-8. [PMID: 27569272 DOI: 10.1021/acsnano.6b04761] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Nanopipettes are becoming extremely versatile and powerful tools in nanoscience for a wide variety of applications from imaging to nanoscale sensing. Herein, the capabilities of nanopipettes to build complex free-standing three-dimensional (3D) nanostructures are demonstrated using a simple double-barrel nanopipette device. Electrochemical control of ionic fluxes enables highly localized delivery of precursor species from one channel and simultaneous (dynamic and responsive) ion conductance probe-to-substrate distance feedback with the other for reliable high-quality patterning. Nanopipettes with 30-50 nm tip opening dimensions of each channel allowed confinement of ionic fluxes for the fabrication of high aspect ratio copper pillar, zigzag, and Γ-like structures, as well as permitted the subsequent topographical mapping of the patterned features with the same nanopipette probe as used for nanostructure engineering. This approach offers versatility and robustness for high-resolution 3D "printing" (writing) and read-out at the nanoscale.
Collapse
Affiliation(s)
- Dmitry Momotenko
- Department of Chemistry and ‡MOAC Doctoral Training Centre, University of Warwick , Coventry, CV4 7AL, United Kingdom
| | - Ashley Page
- Department of Chemistry and ‡MOAC Doctoral Training Centre, University of Warwick , Coventry, CV4 7AL, United Kingdom
| | - Maria Adobes-Vidal
- Department of Chemistry and ‡MOAC Doctoral Training Centre, University of Warwick , Coventry, CV4 7AL, United Kingdom
| | - Patrick R Unwin
- Department of Chemistry and ‡MOAC Doctoral Training Centre, University of Warwick , Coventry, CV4 7AL, United Kingdom
| |
Collapse
|
80
|
Kang M, Momotenko D, Page A, Perry D, Unwin PR. Frontiers in Nanoscale Electrochemical Imaging: Faster, Multifunctional, and Ultrasensitive. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2016; 32:7993-8008. [PMID: 27396415 DOI: 10.1021/acs.langmuir.6b01932] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
A wide range of interfacial physicochemical processes, from electrochemistry to the functioning of living cells, involve spatially localized chemical fluxes that are associated with specific features of the interface. Scanning electrochemical probe microscopes (SEPMs) represent a powerful means of visualizing interfacial fluxes, and this Feature Article highlights recent developments that have radically advanced the speed, spatial resolution, functionality, and sensitivity of SEPMs. A major trend has been a coming together of SEPMs that developed independently and the use of established SEPMs in completely new ways, greatly expanding their scope and impact. The focus is on nanopipette-based SEPMs, including scanning ion conductance microscopy (SICM), scanning electrochemical cell microscopy (SECCM), and hybrid techniques thereof, particularly with scanning electrochemical microscopy (SECM). Nanopipette-based probes are made easily, quickly, and cheaply with tunable characteristics. They are reproducible and can be fully characterized. Their response can be modeled in considerable detail so that quantitative maps of chemical fluxes and other properties (e.g., local charge) can be obtained and analyzed. This article provides an overview of the use of these probes for high-speed imaging, to create movies of electrochemical processes in action, to carry out multifunctional mapping such as simultaneous topography-charge and topography-activity, and to create nanoscale electrochemical cells for the detection, trapping, and analysis of single entities, particularly individual molecules and nanoparticles (NPs). These studies provide a platform for the further application and diversification of SEPMs across a wide range of interfacial science.
Collapse
Affiliation(s)
- Minkyung Kang
- Department of Chemistry and ‡MOAC Doctoral Training Centre, University of Warwick , Coventry CV4 7AL, United Kingdom
| | - Dmitry Momotenko
- Department of Chemistry and ‡MOAC Doctoral Training Centre, University of Warwick , Coventry CV4 7AL, United Kingdom
| | - Ashley Page
- Department of Chemistry and ‡MOAC Doctoral Training Centre, University of Warwick , Coventry CV4 7AL, United Kingdom
| | - David Perry
- Department of Chemistry and ‡MOAC Doctoral Training Centre, University of Warwick , Coventry CV4 7AL, United Kingdom
| | - Patrick R Unwin
- Department of Chemistry and ‡MOAC Doctoral Training Centre, University of Warwick , Coventry CV4 7AL, United Kingdom
| |
Collapse
|
81
|
Affiliation(s)
- David Perry
- Department of Chemistry and ‡MOAC Doctoral Training Centre, University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Dmitry Momotenko
- Department of Chemistry and ‡MOAC Doctoral Training Centre, University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Robert A. Lazenby
- Department of Chemistry and ‡MOAC Doctoral Training Centre, University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Minkyung Kang
- Department of Chemistry and ‡MOAC Doctoral Training Centre, University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Patrick R. Unwin
- Department of Chemistry and ‡MOAC Doctoral Training Centre, University of Warwick, Coventry CV4 7AL, United Kingdom
| |
Collapse
|