51
|
Contrast-enhanced microcomputed tomography using intraperitoneal contrast injection for the assessment of tumor-burden in liver metastasis models. Invest Radiol 2008; 43:488-95. [PMID: 18580331 DOI: 10.1097/rli.0b013e318172f5b5] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
OBJECTIVES To determine if intraperitoneally (IP) administered contrast (iohexol), used in conjunction with a liver-specific agent (Fenestra), can improve measurement precision and accuracy when quantifying tumor volume from micro-CT images of a liver metastasis model. MATERIALS AND METHODS We compared images acquired with Fenestra alone to images acquired with the combination of Fenestra and IP iohexol. The variability in tumor volume and tumor-burden measurement was evaluated for both techniques. The tumor-burden measurement accuracy of both in vivo techniques was determined by comparison with tumor-burden quantified from ex vivo images. RESULTS : The addition of IP iohexol decreased measurement variability for individual tumors and overall tumor-burden by 4-8 fold and 2-3 fold, respectively. IP iohexol significantly improved the accuracy of tumor-burden measurement for both low and high tumor-burdened animals. CONCLUSIONS The combination of IP iohexol with Fenestra provides superior delineation of liver tumors, in comparison to Fenestra alone. The complete tumor delineation provided by this imaging strategy allows for noninvasive quantification of liver tumor-burden.
Collapse
|
52
|
Badea CT, Drangova M, Holdsworth DW, Johnson GA. In vivo small-animal imaging using micro-CT and digital subtraction angiography. Phys Med Biol 2008; 53:R319-50. [PMID: 18758005 DOI: 10.1088/0031-9155/53/19/r01] [Citation(s) in RCA: 170] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
Small-animal imaging has a critical role in phenotyping, drug discovery and in providing a basic understanding of mechanisms of disease. Translating imaging methods from humans to small animals is not an easy task. The purpose of this work is to review in vivo x-ray based small-animal imaging, with a focus on in vivo micro-computed tomography (micro-CT) and digital subtraction angiography (DSA). We present the principles, technologies, image quality parameters and types of applications. We show that both methods can be used not only to provide morphological, but also functional information, such as cardiac function estimation or perfusion. Compared to other modalities, x-ray based imaging is usually regarded as being able to provide higher throughput at lower cost and adequate resolution. The limitations are usually associated with the relatively poor contrast mechanisms and potential radiation damage due to ionizing radiation, although the use of contrast agents and careful design of studies can address these limitations. We hope that the information will effectively address how x-ray based imaging can be exploited for successful in vivo preclinical imaging.
Collapse
Affiliation(s)
- C T Badea
- Center for In Vivo Microscopy, Department of Radiology, Duke University, Durham, NC 27710, USA
| | | | | | | |
Collapse
|
53
|
Chavarrías C, Vaquero JJ, Sisniega A, Rodríguez-Ruano A, Soto-Montenegro ML, García-Barreno P, Desco M. Extraction of the respiratory signal from small-animal CT projections for a retrospective gating method. Phys Med Biol 2008; 53:4683-95. [DOI: 10.1088/0031-9155/53/17/015] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
54
|
Sera T, Yokota H, Fujisaki K, Fukasaku K, Tachibana H, Uesugi K, Yagi N, Himeno R. Development of high-resolution 4Din vivo-CT for visualization of cardiac and respiratory deformations of small animals. Phys Med Biol 2008; 53:4285-301. [DOI: 10.1088/0031-9155/53/16/005] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
55
|
Longitudinal Follow-up of Cardiac Structure and Functional Changes in an Infarct Mouse Model Using Retrospectively Gated Micro-Computed Tomography. Invest Radiol 2008; 43:520-9. [DOI: 10.1097/rli.0b013e3181727519] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
56
|
Badea CT, Schreibmann E, Fox T. A registration based approach for 4D cardiac micro-CT using combined prospective and retrospective gating. Med Phys 2008; 35:1170-9. [PMID: 18491508 DOI: 10.1118/1.2868778] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Recent advances in murine cardiac studies with three-dimensional cone beam micro-computed tomography (CT) have used either prospective or retrospective gating technique. While prospective gating ensures the best image quality and the highest resolution, it involves longer sampling times and higher radiation dose. Sampling is faster and the radiation dose can be reduced with retrospective gating but the image quality is affected by the limited number of projections with an irregular angular distribution which complicate the reconstruction process, causing significant streaking artifacts. This work involves both prospective and retrospective gating in sampling. Deformable registration is used between a high quality image set acquired with prospective gating with the multiple data sets during the cardiac cycle obtained using retrospective gating. Tests were conducted on a four-dimensional (4D) cardiac mouse phantom and after optimization, the method was applied to in vivo cardiac micro-CT data. Results indicate that, by using our method, the sampling time can be reduced by a factor of 2.5 and the radiation dose can be reduced 35% compared to the prospective sampling while the image quality can be maintained. In conclusion, we proposed a novel solution to 4D cine cardiac micro-CT based on a combined prospective with retrospective gating in sampling and deformable registration post reconstruction that mixed the advantages of both strategies.
Collapse
Affiliation(s)
- Cristian T Badea
- Center for In Vivo Microscopy, Duke University Medical Center, Durham, North Carolina 27710, USA.
| | | | | |
Collapse
|
57
|
Badea CT, Wetzel AW, Mistry N, Pomerantz S, Nave D, Johnson GA. Left ventricle volume measurements in cardiac micro-CT: the impact of radiation dose and contrast agent. Comput Med Imaging Graph 2008; 32:239-50. [PMID: 18243656 DOI: 10.1016/j.compmedimag.2007.12.004] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2006] [Revised: 10/03/2007] [Accepted: 12/17/2007] [Indexed: 10/24/2022]
Abstract
Micro-CT-based cardiac function estimation in small animals requires measurement of left ventricle (LV) volume at multiple time points during the cardiac cycle. Measurement accuracy depends on the image resolution, its signal and noise properties, and the analysis procedure. This work compares the accuracy of the Otsu thresholding and a region sampled binary mixture approach, for live mouse LV volume measurement using 100 microm resolution datasets. We evaluate both analysis methods after varying the volume of injected contrast agent and the number of projections used for CT reconstruction with a goal of permitting reduced levels of both X-ray and contrast agent doses.
Collapse
Affiliation(s)
- Cristian T Badea
- Center for In Vivo Microscopy, Duke University Medical Center, Box 3302, Durham, NC 27710, United States.
| | | | | | | | | | | |
Collapse
|
58
|
Intrinsic respiratory gating in small-animal CT. Eur Radiol 2008; 18:1375-84. [DOI: 10.1007/s00330-008-0903-3] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2007] [Revised: 12/01/2007] [Accepted: 01/19/2008] [Indexed: 11/25/2022]
|
59
|
Abstract
Imaging is a noninvasive complement to traditional methods (such as histology) in rodent cardiac studies. Assessments of structure and function are possible with ultrasound, microcomputed tomography (microCT), and magnetic resonance (MR) imaging. Cardiac imaging in the rodent poses a challenge because of the size of the animal and its rapid heart rate. Each aspect in the process of rodent cardiac imaging-animal preparation, choice of anesthetic, selection of gating method, image acquisition, and image interpretation and measurement-requires careful consideration to optimize image quality and to ensure accurate and reproducible data collection. Factors in animal preparation that can affect cardiac imaging are the choice of anesthesia regime (injected or inhaled), intubated or free-breathing animals, physiological monitoring (ECG, respiration, and temperature), and animal restraint. Each will vary depending on the method of imaging and the length of the study. Gating strategies, prospective or retrospective, reduce physiological motion artifacts and isolate specific time points in the cardiac cycle (i.e., end-diastole and end-systole) where measurements are taken. This article includes a simple explanation of the physics of ultrasound, microCT, and MR to describe how images are generated. Subsequent sections provide reviews of animal preparation, image acquisition, and measurement techniques in each modality specific to assessing cardiac functions such as ejection fraction, fractional shortening, stroke volume, cardiac output, and left ventricular mass. The discussion also includes the advantages and disadvantages of the different imaging modalities. With the use of ultrasound, microCT, and MR, it is possible to create 2-, 3-, and 4-dimensional views to characterize the structure and function of the rodent heart.
Collapse
Affiliation(s)
- Kennita Johnson
- Laboratory of Experimental Pathology, National Institute of Environmental Health Sciences in Research Triangle Park, NC 27709, USA.
| |
Collapse
|
60
|
Noninvasive quantification of tumor volume in preclinical liver metastasis models using contrast-enhanced x-ray computed tomography. Invest Radiol 2008; 43:92-9. [PMID: 18197061 DOI: 10.1097/rli.0b013e31815603d7] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES To determine a timepoint after contrast injection that yields equal liver parenchymal and vascular enhancement in micro-computed tomography images. To evaluate the utility of images acquired during this time period for the noninvasive measurement of liver-tumor volume. MATERIALS AND METHODS The imaging timepoint was determined by quantifying the enhancement kinetics of Fenestra VC (0.015 mL/g) in NIH III mice. In respiratory-gated images of tumor bearing mice, the ability to measure tumor volume was evaluated with a measurement variability study, and by comparing in vivo and histologically measured tumor volume. RESULTS Eight hours after contrast injection the liver parenchyma and vasculature were equally enhanced allowing for clear delineation of the unenhanced tumors. The smallest tumor detected in this study was 1.1 mm in diameter. The coefficient of variation for tumor-volume measurement ranged from 3.6% to 12.9% and from 6.3% to 25.8% for intra and interobserver variability, respectively. In vivo and histologic tumor-volume measurements were closely correlated (r = 0.98, P < 0.0001). CONCLUSIONS Imaging at a time period of equal liver parenchyma and vascular enhancement after contrast injection allows for clear delineation of liver-tumor borders, thereby enabling quantitative tumor-volume monitoring.
Collapse
|
61
|
Seo Y, Hashimoto T, Nuki Y, Hasegawa BH. In vivo microCT imaging of rodent cerebral vasculature. Phys Med Biol 2008; 53:N99-107. [PMID: 18364539 DOI: 10.1088/0031-9155/53/7/n01] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Computed tomography (CT) remains a critical diagnostic tool for evaluating patients with cerebrovascular disease, and the advent of specialized systems for imaging rodents has extended these techniques to small animal models of these diseases. We therefore have evaluated in vivo methods of imaging rat models of hemorrhagic stroke using a high resolution compact computed tomography ('microCT') system (FLEX(tm) X-O(tm), Gamma Medica-Ideas, Northridge, CA). For all in vivo studies, the head of the anesthetized rat was secured in a custom immobilization device for microCT imaging with 512 projections over 2 min at 60 kVp and 0.530 mA (I(tube) x t/rotation=63.6 mAs). First, imaging without iodinated contrast was performed (a) to differentiate the effect of contrast agent in contrast-enhanced CT and (b) to examine the effectiveness of the immobilization device between two time points of CT acquisitions. Then, contrast-enhanced CT was performed with continuous administration of iopromide (300 mgI ml(-1) at 1.2 ml min(-1)) to visualize aneurysms and other vascular formations in the carotid and cerebral arteries that may precede subarachnoid hemorrhage. The accuracy of registration between the noncontrast and contrast-enhanced CT images with the immobilization device was compared against the images aligned with normalized mutual information using FMRIB's linear image registration tool (FLIRT). Translations and rotations were examined between the FLIRT-aligned noncontrast CT image and the nonaligned noncontrast CT image. These two data sets demonstrated translational and rotational differences of less than 0.5 voxel (approximately 85 microm) and 0.5 degrees, respectively. Noncontrast CT demonstrated a very small volume (0.1 ml) of femoral arterial blood introduced surgically into the rodent brain. Continuous administration of iopromide during the CT acquisition produced consistent vascular contrast in the reconstructed CT images. As a result, carotid arteries and major cerebral blood vessels were visible with contrast-enhanced CT, but not with noncontrast CT. In conclusion, the CT-compatible immobilization device was useful for in vivo microCT imaging of intracranial blood and of vascular structures within and immediately adjacent to the rodent brain. The microCT imaging technique is also compatible with continuous administration of a conventional iodinated contrast agent (e.g. iopromide) and therefore does not require specialized small animal specific contrast agent that has comparatively long in vivo residence time.
Collapse
Affiliation(s)
- Youngho Seo
- Center for Molecular and Functional Imaging, Department of Radiology, University of California, San Francisco, CA 94143, USA.
| | | | | | | |
Collapse
|
62
|
Song J, Liu QH, Johnson GA, Badea CT. Sparseness prior based iterative image reconstruction for retrospectively gated cardiac micro-CT. Med Phys 2008; 34:4476-83. [PMID: 18072512 DOI: 10.1118/1.2795830] [Citation(s) in RCA: 136] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Recent advances in murine cardiac studies with three-dimensional (3D) cone beam micro-CT used a retrospective gating technique. However, this sampling technique results in a limited number of projections with an irregular angular distribution due to the temporal resolution requirements and radiation dose restrictions. Both angular irregularity and undersampling complicate the reconstruction process, since they cause significant streaking artifacts. This work provides an iterative reconstruction solution to address this particular challenge. A sparseness prior regularized weighted l2 norm optimization is proposed to mitigate streaking artifacts based on the fact that most medical images are compressible. Total variation is implemented in this work as the regularizer for its simplicity. Comparison studies are conducted on a 3D cardiac mouse phantom generated with experimental data. After optimization, the method is applied to in vivo cardiac micro-CT data.
Collapse
Affiliation(s)
- Jiayu Song
- Center for In Vivo Microscopy, Box 3302, Duke University Medical Center, Durham, North Carolina 27710, USA
| | | | | | | |
Collapse
|
63
|
Abstract
OBJECTIVES Implementation and evaluation of retrospective respiratory and cardiac gating of mice and rats using a flat-panel volume-CT prototype (fpVCT). MATERIALS AND METHODS Respiratory and cardiac gating was implemented by equipping a fpVCT with a small animal monitoring unit. ECG and breathing excursions were recorded and 2 binary gating signals derived. Mice and rats were scanned continuously over 80 seconds after administration of blood-pool contrast media. Projections were chosen to reconstruct volumes that fall within defined phases of the cardiac/respiratory cycle. RESULTS Multireader analysis indicated that in gated still images motion artifacts were strongly reduced and diaphragm, tracheobronchial tract, heart, and vessels sharply delineated. From 4D series, functional data such as respiratory tidal volume and cardiac ejection fraction were calculated and matched well with values known from literature. DISCUSSION Implementation of retrospective gating in fpVCT improves image quality and opens new perspectives for functional cardiac and lung imaging in small animals.
Collapse
|
64
|
Du LY, Umoh J, Nikolov HN, Pollmann SI, Lee TY, Holdsworth DW. A quality assurance phantom for the performance evaluation of volumetric micro-CT systems. Phys Med Biol 2007; 52:7087-108. [PMID: 18029995 DOI: 10.1088/0031-9155/52/23/021] [Citation(s) in RCA: 110] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Small-animal imaging has recently become an area of increased interest because more human diseases can be modeled in transgenic and knockout rodents. As a result, micro-computed tomography (micro-CT) systems are becoming more common in research laboratories, due to their ability to achieve spatial resolution as high as 10 microm, giving highly detailed anatomical information. Most recently, a volumetric cone-beam micro-CT system using a flat-panel detector (eXplore Ultra, GE Healthcare, London, ON) has been developed that combines the high resolution of micro-CT and the fast scanning speed of clinical CT, so that dynamic perfusion imaging can be performed in mice and rats, providing functional physiological information in addition to anatomical information. This and other commercially available micro-CT systems all promise to deliver precise and accurate high-resolution measurements in small animals. However, no comprehensive quality assurance phantom has been developed to evaluate the performance of these micro-CT systems on a routine basis. We have designed and fabricated a single comprehensive device for the purpose of performance evaluation of micro-CT systems. This quality assurance phantom was applied to assess multiple image-quality parameters of a current flat-panel cone-beam micro-CT system accurately and quantitatively, in terms of spatial resolution, geometric accuracy, CT number accuracy, linearity, noise and image uniformity. Our investigations show that 3D images can be obtained with a limiting spatial resolution of 2.5 mm(-1) and noise of +/-35 HU, using an acquisition interval of 8 s at an entrance dose of 6.4 cGy.
Collapse
Affiliation(s)
- Louise Y Du
- Department of Medical Biophysics, University of Western Ontario, London, ON, Canada
| | | | | | | | | | | |
Collapse
|
65
|
Ford NL, Wheatley AR, Holdsworth DW, Drangova M. Optimization of a retrospective technique for respiratory-gated high speed micro-CT of free-breathing rodents. Phys Med Biol 2007; 52:5749-69. [PMID: 17881798 DOI: 10.1088/0031-9155/52/19/002] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The objective of this study was to develop a technique for dynamic respiratory imaging using retrospectively gated high-speed micro-CT imaging of free-breathing mice. Free-breathing C57Bl6 mice were scanned using a dynamic micro-CT scanner, comprising a flat-panel detector mounted on a slip-ring gantry. Projection images were acquired over ten complete gantry rotations in 50 s, while monitoring the respiratory motion in synchrony with projection-image acquisition. Projection images belonging to a selected respiratory phase were retrospectively identified and used for 3D reconstruction. The effect of using fewer gantry rotations--which influences both image quality and the ability to quantify respiratory function--was evaluated. Images reconstructed using unique projections from six or more gantry rotations produced acceptable images for quantitative analysis of lung volume, CT density, functional residual capacity and tidal volume. The functional residual capacity (0.15 +/- 0.03 mL) and tidal volumes (0.08 +/- 0.03 mL) measured in this study agree with previously reported measurements made using prospectively gated micro-CT and at higher resolution (150 microm versus 90 microm voxel spacing). Retrospectively gated micro-CT imaging of free-breathing mice enables quantitative dynamic measurement of morphological and functional parameters in the mouse models of respiratory disease, with scan times as short as 30 s, based on the acquisition of projection images over six gantry rotations.
Collapse
Affiliation(s)
- Nancy L Ford
- Department of Physics, Ryerson University, 350 Victoria Street, Toronto, Ontario M5B 2K3, Canada.
| | | | | | | |
Collapse
|