Kirk R, Rowe MT. A PCR assay for the detection of Campylobacter jejuni and Campylobacter coli in water.
Lett Appl Microbiol 1994;
19:301-3. [PMID:
7765441 DOI:
10.1111/j.1472-765x.1994.tb00460.x]
[Citation(s) in RCA: 44] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
A PCR assay has been developed for the detection of Campylobacter jejuni and Camp. coli in water samples. The sample is filtered through a membrane which is subjected to sonication to release the impacted cells. After removal of the filter from the cell suspension and a freeze/thaw cell lysis step, a semi-nested PCR is carried out on the filtrate using the primers CF02, CF03 and CF04 (Camp. jejuni flaA and flaB gene sequences). Incorporation of a sonication stage allows removal of the filter membrane since they have been shown to inhibit the PCR. In experiments with spike water samples (20 ml) a theoretical sensitivity of 10-20 campylobacter cells ml-1 was achieved. Using a sample volume of 100 ml this sensitivity can be increased to approximately 2 campylobacter cells ml-1.
Collapse