51
|
Faria-Correia F, Lopes B, Monteiro T, Franqueira N, Ambrósio R. Scheimpflug lens densitometry and ocular wavefront aberrations in patients with mild nuclear cataract. J Cataract Refract Surg 2016; 42:405-11. [DOI: 10.1016/j.jcrs.2015.10.069] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2015] [Revised: 10/04/2015] [Accepted: 10/07/2015] [Indexed: 11/16/2022]
|
52
|
Kar T, Aksoy Y, Yıldırım Y, Kaya A, Ayata A, Ünal MH. Quantitative Scheimpflug camera study of the lens density in healthy Turkish population. Int Ophthalmol 2016; 36:819-827. [PMID: 26914505 DOI: 10.1007/s10792-016-0203-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2015] [Accepted: 02/13/2016] [Indexed: 11/26/2022]
Abstract
The purpose of this study is to evaluate the association between the age and the density of anterior, posterior, and nuclear parts of lens and detect the normal lens density (LD) values in different age groups. 370 eyes of 370 voluntary healthy Turkish subjects were included. These were divided in four groups according to their age. These were Group 1 (51-65 years), Group 2 (41-50 years), Group 3 (31-40 years) and Group 4 (20-30 years). LD values of anterior, nuclear, posterior, and total (average) were measured using Pentacam HR Scheimpflug camera system. Both eyes of each subject were scanned twice in automatic release and 50-picture 3-dimensional (3D) scan modes by one experienced observer. 207 of the participants were females and 163 were males, with a mean age of 40.57 ± 13.06 years. The differences between groups in terms of nuclear area, posterior area, and average LD measurements were significant but anterior area was not. The nuclear area and average LD had high positive correlation with age (r = 0.72, p < 0.001, r = 0.63, p < 0.001, respectively); posterior area LD had a weak negative correlation with age (r = -0.16, p = 0.001). The mean LD values between female and male subjects showed no significant difference. The anterior region of the lens has the highest and nuclear area has the lowest value of LD in young people. In older people, the anterior area did not show a significant change, nuclear and total areas showed a significant increase but posterior area showed a significant decrease.
Collapse
Affiliation(s)
- Taner Kar
- Department of Ophthalmology, Gulhane Military Medical Academy, Haydarpasa Training Hospital, Uskudar, Istanbul, Turkey
| | - Yakup Aksoy
- Department of Ophthalmology, Girne Military Hospital, 99300, Girne, Cyprus.
| | - Yıldıray Yıldırım
- Department of Ophthalmology, Gulhane Military Medical Academy, Haydarpasa Training Hospital, Uskudar, Istanbul, Turkey
| | - Abdullah Kaya
- Department of Ophthalmology, Gulhane Military Medical Academy, Haydarpasa Training Hospital, Uskudar, Istanbul, Turkey
| | - Ali Ayata
- Department of Ophthalmology, Gulhane Military Medical Academy, Haydarpasa Training Hospital, Uskudar, Istanbul, Turkey
| | - Melih Hamdi Ünal
- Department of Ophthalmology, Gulhane Military Medical Academy, Haydarpasa Training Hospital, Uskudar, Istanbul, Turkey
| |
Collapse
|
53
|
Domínguez-Vicent A, Birkeldh U, Carl-Gustaf L, Nilson M, Brautaset R. Objective Assessment of Nuclear and Cortical Cataracts through Scheimpflug Images: Agreement with the LOCS III Scale. PLoS One 2016; 11:e0149249. [PMID: 26890694 PMCID: PMC4758745 DOI: 10.1371/journal.pone.0149249] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2015] [Accepted: 01/28/2016] [Indexed: 11/18/2022] Open
Abstract
PURPOSE To assess nuclear and cortical opacities through the objective analysis of Scheimpflug images, and to check the correlation with the Lens Opacity Classification System III (LOCS III). METHODS Nuclear and cortical opacities were graded according to the LOCS III rules after pupil dilation. The maximum and average pixel intensity values along an elliptical mask within the lens nucleus were taken to analyse nuclear cataracts. A new metric based on the percentage of opaque pixels within a region of interest was used to analyse cortical cataracts. The percentage of opaque pixels was also calculated for half, third and quarter areas from the region of interest's periphery. RESULTS The maximum and average intensity values along the nucleus were directly proportional to the LOCS III grade: The larger the LOCS III value, the larger maximum and average intensity ones. These metrics showed a positive and significant correlation with the LOCS grade: The larger the LOCS grade, the higher was percentage of opaque pixels along the cortex within the same mask's size. This metric showed a significant correlation to the LOCS grade. CONCLUSION The metrics used to assess nuclear opacities showed good correlation with the LOCS III. The percentage of opaque pixels showed to be a useful metric to measure objectively the severity of the cortical opacity. These metrics could be implemented in an algorithm to detect and grade lens opacities automatically and objectively.
Collapse
Affiliation(s)
- Alberto Domínguez-Vicent
- Optometry Research Group, Department of Optics and Optometry and Vision Science, University of Valencia, Burjasot, Comunidad Valenciana, Spain
- * E-mail:
| | - Ulrika Birkeldh
- Unit of Optometry, Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
- St. Erik Eye Hospital, Stockholm, Sweden
| | - Laurell Carl-Gustaf
- Unit of Optometry, Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
- St. Erik Eye Hospital, Stockholm, Sweden
| | - Maria Nilson
- Unit of Optometry, Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
| | - Rune Brautaset
- Unit of Optometry, Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
| |
Collapse
|
54
|
Minami K, Honbo M, Mori Y, Kataoka Y, Miyata K. Area densitometry using rotating Scheimpflug photography for posterior capsule opacification and surface light scattering analyses. J Cataract Refract Surg 2015; 41:2444-9. [DOI: 10.1016/j.jcrs.2015.05.038] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2015] [Revised: 05/20/2015] [Accepted: 05/22/2015] [Indexed: 11/24/2022]
|
55
|
Lim SA, Hwang J, Hwang KY, Chung SH. Objective assessment of nuclear cataract: comparison of double-pass and Scheimpflug systems. J Cataract Refract Surg 2015; 40:716-21. [PMID: 24767907 DOI: 10.1016/j.jcrs.2013.10.032] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2013] [Revised: 09/26/2013] [Accepted: 10/02/2013] [Indexed: 11/15/2022]
Abstract
PURPOSE To compare the objective assessment of lens density by 2 systems (double-pass Optical Quality Analysis System and Pentacam Scheimpflug) in eyes with age-related nuclear cataract. SETTING Department of Ophthalmology and Visual Science, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, South Korea. DESIGN Cross-sectional study. METHODS In eyes with age-related nuclear cataract, the objective lens density (0 to 100 points) was determined using the Scheimpflug system while subjective grading was achieved using the Lens Opacities Classification System III (LOCS III). The objective scatter index (OSI) (0 to 25) was assessed using the double-pass system. RESULTS This study enrolled 47 patients (70 eyes). The mean OSI was 4.08 ± 2.22 (SD), and the mean Scheimpflug-measured lens density was 16.44 ± 4.36; the 2 parameters were correlated (r = 0.764, P<.01). There was a positive linear correlation between the OSI and LOCS III grading scores for nuclear opalescence and nuclear color (r = 0.772 and r = 0.752, respectively; P<.01). The cumulated dissipated energy (CDE) was strongly correlated with the OSI (r = 0.768) and Scheimpflug-measured lens density (r = 0.753). CONCLUSIONS The OSI based on the double-pass system was correlated with the Scheimpflug-measured lens density, subjective lens grading, and CDE. The OSI may improve the preoperative evaluation of nuclear cataract and help predict phacodynamics in cataract surgery.
Collapse
Affiliation(s)
- Sung A Lim
- From the Department of Ophthalmology and Visual Science (Lim, J. Hwang, K.-Y. Hwang, Chung), Seoul St. Mary's Hospital, Catholic University of Korea, and the Catholic Institute for Visual Science (Chung), College of Medicine, The Catholic University of Korea, Seoul, South Korea
| | - Jehyung Hwang
- From the Department of Ophthalmology and Visual Science (Lim, J. Hwang, K.-Y. Hwang, Chung), Seoul St. Mary's Hospital, Catholic University of Korea, and the Catholic Institute for Visual Science (Chung), College of Medicine, The Catholic University of Korea, Seoul, South Korea
| | - Kyu-Yeon Hwang
- From the Department of Ophthalmology and Visual Science (Lim, J. Hwang, K.-Y. Hwang, Chung), Seoul St. Mary's Hospital, Catholic University of Korea, and the Catholic Institute for Visual Science (Chung), College of Medicine, The Catholic University of Korea, Seoul, South Korea
| | - So-Hyang Chung
- From the Department of Ophthalmology and Visual Science (Lim, J. Hwang, K.-Y. Hwang, Chung), Seoul St. Mary's Hospital, Catholic University of Korea, and the Catholic Institute for Visual Science (Chung), College of Medicine, The Catholic University of Korea, Seoul, South Korea.
| |
Collapse
|
56
|
Repeatability of lens densitometry using Scheimpflug imaging. J Cataract Refract Surg 2015; 40:756-63. [PMID: 24767909 DOI: 10.1016/j.jcrs.2013.10.039] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2013] [Revised: 09/11/2013] [Accepted: 10/11/2013] [Indexed: 11/24/2022]
Abstract
PURPOSE To evaluate the repeatability of different lens densitometry analysis modes performed with Scheimpflug imaging using the Pentacam HR device. SETTING University eye hospital, Frankfurt am Main, Germany. DESIGN Cross-sectional study. METHODS Eyes were analyzed under mydriasis during 2 examinations performed by the same examiner. Three single measurements were taken to assess lens densitometry via 3 modes as follows: peak (maximum), linear (vertical axis), and 3-dimensional (3-D). Measurements were also taken using 3 cylindrical reference blocks (P) with different diameters (2.0 mm, 4.0 mm, 6.00 mm) composing the whole lens depth. Repeatability was tested using Bland-Altman analysis. As statistical parameters, the coefficient of repeatability (CoR) and the relative repeatability (RR) were applied. RESULTS The study analyzed 105 eyes. The CoR of the peak modus was 5.6 (RR, 29.8%); of the linear modus, 0.9 (RR, 8.8%); and of the 3-D modus, 0.36 (RR, 3.6%). The values of the P mode were lower, with a CoR between 0.19 and 0.30 (RR, 2.1%-3.3%). CONCLUSIONS Lens densitometry using Scheimpflug imaging was highly repeatable. However, repeatability was dependent on the analysis mode used. Repeatability decreased with increasing opacification.
Collapse
|
57
|
Evaluation of a 345 nm Femtosecond Laser for Corneal Surgery with Respect to Intraocular Radiation Hazard. PLoS One 2015; 10:e0137638. [PMID: 26361228 PMCID: PMC4567343 DOI: 10.1371/journal.pone.0137638] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2015] [Accepted: 08/19/2015] [Indexed: 01/03/2023] Open
Abstract
PURPOSE We report our findings from a preclinical safety study designed to assess potential side effects of corneal ultraviolet femtosecond laser treatment on lens and retina. METHODS Refractive lenticules (-5 dpt) with a diameter of 6 mm were created in the right cornea of eight Dutch Belted rabbits. Radiant exposure was 0.5 J/cm² in two animals and 18 J/cm² in six animals. The presence of lens opacities was assessed prior to and up to six months following laser application using Scheimpflug images (Pentacam, Oculus) and backscatter analysis (Opacity Lensmeter 702, Interzeag). Ganzfeld flash and flicker electroretinogram (ERG) recordings were obtained from both eyes prior to and up to six weeks following laser application. At the study endpoint, retinas were examined by light microscopy. RESULTS Independent of energy dose applied, no cataract formation could be observed clinically or with either of the two objective methods used. No changes in ERG recordings over time and no difference between treated and untreated eye were detected. Histologically, retinal morphology was preserved and retinal pigment epithelium as well as photoreceptor inner and outer segments appeared undamaged. Quantitative digital image analysis did not reveal cell loss in inner or outer nuclear layers. CONCLUSIONS Our analysis confirms theoretical considerations suggesting that ultraviolet femtosecond laser treatment of the cornea is safe for intraocular tissues. Transmitted light including stray light induces no photochemical effects in lens or retina at energy levels much higher than required for the clinical purpose. These conclusions cannot be applied to eyes with pre-existing retinal damage, as these may be more vulnerable to light.
Collapse
|
58
|
Influence of anterior chamber depth, anterior chamber volume, axial length, and lens density on postoperative endothelial cell loss. Graefes Arch Clin Exp Ophthalmol 2015; 253:745-52. [DOI: 10.1007/s00417-015-2934-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2014] [Revised: 01/07/2015] [Accepted: 01/12/2015] [Indexed: 01/26/2023] Open
|
59
|
Pan AP, Wang QM, Huang F, Huang JH, Bao FJ, Yu AY. Correlation among lens opacities classification system III grading, visual function index-14, pentacam nucleus staging, and objective scatter index for cataract assessment. Am J Ophthalmol 2015; 159:241-7.e2. [PMID: 25448993 DOI: 10.1016/j.ajo.2014.10.025] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2014] [Revised: 10/24/2014] [Accepted: 10/24/2014] [Indexed: 10/24/2022]
Abstract
PURPOSE To investigate the relationship among Lens Opacities Classification System III (LOCS III) grading score, Visual Function Index-14 (VF-14) score, average lens density by the Pentacam Nucleus Staging system, and the objective scatter index measured by the Optical Quality Analysis System in age-related cataract patients. DESIGN Prospective, single-center, cross-sectional study. METHODS Thirty-six subjects (60 eyes) with age-related cataract were recruited. Subjects with any corneal anomaly potentially affecting intraocular scatter were excluded. The best-corrected visual acuity (BCVA), LOCS III nuclear opalescence score and cortical cataract score, VF-14 score, average lens density, and objective scatter index were obtained. Correlations among these parameters were analyzed. RESULTS The LOCS III nuclear opalescence score was correlated with the BCVA (r = 0.438; P = .001), objective scatter index (r = 0.543; P < .001), and average lens density (r = 0.621; P < .001). The objective scatter index was also correlated with the BCVA (r = 0.779; P < .001) and the average lens density (r = 0.320; P = .013). The VF-14 score had the strongest correlation with the objective scatter index (r = -0.712; P < .001). The difference between groups with objective scatter index<3.0 and ≥3.0 was significant with regard to BCVA, average lens density, LOCS III nuclear opalescence score, and VF-14 score. CONCLUSIONS LOCS III grading remains an economical and effective method to assess lens opacities, especially in the formation of early cortex cataracts. The objective scatter index can be a useful parameter to objectively analyze the correlation between ocular examination findings and patient concerns. Furthermore, the objective scatter index scores ≥3.0 can be a possible objective cut-off for preoperative decision making.
Collapse
|
60
|
Min SG, Ko BY. The Relationship between the Nuclear Density Using Scheimpflug Imaging with Phacoemulsification Parameters. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2015. [DOI: 10.3341/jkos.2015.56.10.1552] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Seong Gyu Min
- Department of Ophthalmology, Konyang University College of Medicine, Daejeon, Korea
| | - Byung Yi Ko
- Department of Ophthalmology, Konyang University College of Medicine, Daejeon, Korea
| |
Collapse
|
61
|
Ro JW, Yi KY, Kim HK, Hyon JY, Wee WR, Shin YJ. Internal Lens Signal Measured by Dual Scheimpflug Anterior Segment Analyzer. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2015. [DOI: 10.3341/jkos.2015.56.5.702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Jin Woo Ro
- Department of Ophthalmology, Hallym University College of Medicine, Chuncheon, Korea
| | - Ka Young Yi
- Department of Ophthalmology, Hallym University College of Medicine, Chuncheon, Korea
| | - Ha Kyung Kim
- Department of Ophthalmology, Hallym University College of Medicine, Chuncheon, Korea
| | - Joon Young Hyon
- Department of Ophthalmology, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Korea
- Department of Ophthalmology, Seoul National University College of Medicine, Seoul, Korea
| | - Won Ryang Wee
- Department of Ophthalmology, Seoul National University College of Medicine, Seoul, Korea
| | - Young Joo Shin
- Department of Ophthalmology, Hallym University College of Medicine, Chuncheon, Korea
| |
Collapse
|
62
|
Kamiya K, Shimizu K, Iijima A, Kobashi H. Factors influencing contrast sensitivity function in myopic eyes. PLoS One 2014; 9:e113562. [PMID: 25401751 PMCID: PMC4234649 DOI: 10.1371/journal.pone.0113562] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2014] [Accepted: 10/25/2014] [Indexed: 11/18/2022] Open
Abstract
Purpose To evaluate the factors affecting the area under the log contrast sensitivity function (AULCSF) in healthy myopic eyes. Methods We retrospectively examined 201 eyes of 201 consecutive subjects (age, 31.8±7.4 years (mean ± standard deviation)) with myopic refractive errors of −1.25 to −8.25 diopters (D). From the contrast sensitivity data, the area under the log contrast sensitivity function (AULCSF) was calculated. Stepwise multiple regression analysis was used to assess the factors affecting the AULCSF. Results The mean AULSCF was 1.09±0.09 (0.89 to 1.55). Explanatory variables relevant to the AULCSF were, in order of influence, the objective scattering index (OSI) (p = 0.018, partial regression coefficient B = –0.032) and logMAR CDVA (p = 0.022, B = –0.209) (adjusted R2 = 0.231). No significant correlation was seen with other clinical factors such as gender, manifest refraction, pupil size, lens density, corneal HOAs, or ocular HOAs. Conclusions Although the great majority of the variance remains unexplained, eyes with lower OSI and better CDVA are more predisposed to show higher contrast sensitivity function. These results indicate that not only CDVA but also intraocular forward scattering may play some role in predicting the contrast sensitivity function in myopic subjects.
Collapse
Affiliation(s)
- Kazutaka Kamiya
- Department of Ophthalmology, University of Kitasato School of Medicine, Sagamihara, Kanagawa, Japan
- * E-mail:
| | - Kimiya Shimizu
- Department of Ophthalmology, University of Kitasato School of Medicine, Sagamihara, Kanagawa, Japan
| | - Ayaka Iijima
- Department of Ophthalmology, University of Kitasato School of Medicine, Sagamihara, Kanagawa, Japan
| | - Hidenaga Kobashi
- Department of Ophthalmology, University of Kitasato School of Medicine, Sagamihara, Kanagawa, Japan
| |
Collapse
|
63
|
Lim DH, Kim TH, Chung ES, Chung TY. Measurement of lens density using Scheimpflug imaging system as a screening test in the field of health examination for age-related cataract. Br J Ophthalmol 2014; 99:184-91. [PMID: 25204988 DOI: 10.1136/bjophthalmol-2014-305632] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
PURPOSE To assess Pentacam (Oculus, Wetzlar, Germany) Scheimpflug quantitative images in evaluating lens density and providing objective measurements to suggest optimal time of cataract surgery in the field of health examination. METHODS Two hundred and twenty-nine eyes with age-related cataract were enrolled. Lens density was measured using Pentacam. All Pentacam images were exported to ImageJ (NIH, Bethesda, Maryland, USA) for quantitative analysis. Average lens density (ALD) and nuclear lens density (NLD) were calculated. Lens density was also evaluated by built-in Pentacam Nucleus Staging (PNS) software. Slit-lamp microscopy was performed for cataract grading according to Lens Opacification Classification System III (LOCS III). The best-corrected visual acuity (BCVA) was measured. All measurements were compared between the cataract surgery and non-cataract surgery groups. RESULTS The measurements of Pentacam images significantly correlated with LOCS III for nuclear opalescence (NO) and nuclear colour (NC) grading (p<0.01). Pentacam ImageJ showed higher correlation than PNS. The mean NLD was most highly correlated with NO (r=0.8833) and NC (r=0.6815). The maximum ALD was most highly correlated with cortical opacity (r=0.5381). All Pentacam measurements of lens density and BCVA were significantly different between the cataract surgery and non-surgery groups (p<0.01). The optimised cut-off values to perform cataract surgery for mean NLD and maximum ALD were 26 and 74, respectively (p<0.01). CONCLUSIONS The Pentacam ImageJ method provided objective measurements to evaluate cataracts needing surgery. The method has the potential to be generally applied in the field of health examination and is effective in screening patients with cataract.
Collapse
Affiliation(s)
- Dong Hui Lim
- Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea Department of Preventive Medicine, Catholic University School of Medicine, Seoul, Republic of Korea
| | - Tae Hyup Kim
- Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Eui-Sang Chung
- Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Tae-Young Chung
- Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| |
Collapse
|
64
|
Kamiya K, Shimizu K, Igarashi A, Kobashi H. Factors influencing long-term regression after posterior chamber phakic intraocular lens implantation for moderate to high myopia. Am J Ophthalmol 2014; 158:179-184.e1. [PMID: 24699155 DOI: 10.1016/j.ajo.2014.03.010] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2013] [Revised: 03/18/2014] [Accepted: 03/20/2014] [Indexed: 11/19/2022]
Abstract
PURPOSE To evaluate the factors affecting the long-term regression after posterior chamber phakic intraocular lens (Visian ICL; STAAR Surgical) implantation for myopia. DESIGN Retrospective observational case series. METHODS We retrospectively examined 60 eyes of 35 consecutive patients (age, 38.4 ± 9.3 years [mean ± standard deviation]) with myopic refractive errors of -4.00 to -15.25 diopters (D) undergoing ICL implantation. We assessed the amount of myopic regression from 1 month to 6 years after surgery. Stepwise multiple regression analysis was used to assess the factors affecting the amount of myopic regression. RESULTS The mean myopic regression from 1 month to 6 years after surgery was -0.33 ± 0.71 D (0.75 to -3.00 D). Explanatory variables relevant to the myopic regression were, in order of influence, patient age (partial regression coefficient B = -0.042, P < .0001) and preoperative axial length (B = -0.186, P = .013) (adjusted R(2) = 0.300). No significant correlation was seen with other clinical factors such as sex, preoperative refraction, intraocular pressure, white-to-white distance, anterior chamber depth, central corneal thickness, or mean keratometric readings. CONCLUSIONS Although the great majority of the variance remains unexplained, eyes of older patients and eyes with longer axial length are more predisposed to show greater myopic regression after ICL implantation. These results indicate that not only patient age but also axial length may play some role in predicting the long-term refractive outcomes of this surgical procedure.
Collapse
Affiliation(s)
- Kazutaka Kamiya
- Department of Ophthalmology, University of Kitasato School of Medicine, Kanagawa, Japan.
| | - Kimiya Shimizu
- Department of Ophthalmology, University of Kitasato School of Medicine, Kanagawa, Japan
| | - Akihito Igarashi
- Department of Ophthalmology, University of Kitasato School of Medicine, Kanagawa, Japan
| | - Hidenaga Kobashi
- Department of Ophthalmology, University of Kitasato School of Medicine, Kanagawa, Japan
| |
Collapse
|
65
|
The Effect of Chronic Smoking on Lens Density in Young Adults. Eur J Ophthalmol 2014; 24:682-7. [DOI: 10.5301/ejo.5000454] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/05/2014] [Indexed: 11/20/2022]
Abstract
Purpose To investigate the effect of chronic cigarette smoking on lens density by Pentacam HR lens densitometry in young adults. Methods Sixty chronic smokers who smoked at least 10 cigarettes per day for at least 2 years and 60 age- and sex-matched healthy control subjects were included in this prospective cross-sectional, comparative study. Presence of an ocular or systemic disease that might affect lens were determined as exclusion criteria. All individuals underwent complete ocular examination. Lens densitometry (LD) measurements were performed with Pentacam HR (Oculus, Wetzlar, Germany), dividing the lens into 3 areas: anterior area (anterior subcapsular and anterior cortical), nuclear area, and posterior area (posterior subcapsular and posterior cortical). Three-dimensional scan modes were used for measurements. Results The mean ages of group 1 and 2 were 25.85 ± 4.32 and 25.60 ± 5.14 years, respectively. The mean LD values in the 3 areas were higher in group 1 than group 2. However, only the mean LD value at the anterior area of group 1 was found to be statistically significantly higher (p = 0.047). There was no statistically significant difference in the mean LD measurements at the nuclear and posterior areas between the groups. Conclusions Our study demonstrated that the mean LD value of the anterior area was significantly higher in group 1, suggesting that chronic smoking may contribute to anterior cortical and subcapsular cataract development in young adults.
Collapse
|
66
|
|
67
|
Correlación de la densidad del cristalino medida por imágenes de Scheimpflug y parámetros facodinámicos en la optimización de la facoemulsificación. REVISTA MEXICANA DE OFTALMOLOGÍA 2014. [DOI: 10.1016/j.mexoft.2014.04.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
|
68
|
Kim SI, Oh TH. Effects of Topical Tranilast on Corneal Haze with the Pentacam® after Photorefractive Keratectomy. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2014. [DOI: 10.3341/jkos.2014.55.9.1277] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Sung In Kim
- Department of Ophthalmology, Saevit Eye Hospital, Goyang, Korea
| | - Tae Hoon Oh
- Department of Ophthalmology, Saevit Eye Hospital, Goyang, Korea
| |
Collapse
|
69
|
Gupta M, Ram J, Jain A, Sukhija J, Chaudhary M. Correlation of nuclear density using the Lens Opacity Classification System III versus Scheimpflug imaging with phacoemulsification parameters. J Cataract Refract Surg 2013; 39:1818-23. [DOI: 10.1016/j.jcrs.2013.05.052] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2012] [Revised: 05/22/2013] [Accepted: 05/26/2013] [Indexed: 10/26/2022]
|
70
|
Grewal DS, Grewal SPS. Clinical applications of Scheimpflug imaging in cataract surgery. Saudi J Ophthalmol 2013; 26:25-32. [PMID: 23960965 DOI: 10.1016/j.sjopt.2011.11.001] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/15/2022] Open
Abstract
Since the Scheimpflug principle was first described over a century ago, there has been a great interest among ophthalmologists for the use of Scheimpflug camera in anterior segment imaging. Scheimpflug imaging has since advanced significantly and modern day instruments provide comprehensive imaging and topographic data of the anterior segment. In this article the clinical applications and limitations of Scheimpflug imaging in modern cataract surgery patients are discussed. This article reviews recent work on assessment of lens transparency for cataract grading and integrity, using preoperative lens density measurements to help predict phacoemulsification parameters, its utility in challenging situations like capsular bag distension syndrome and traumatic cataract and assessment of density of the posterior capsule for objectively quantifying posterior-capsule opacification.
Collapse
|
71
|
Increased Ocular Lens Density in HIV-Infected Individuals With Low Nadir CD4 Counts in South Africa. J Acquir Immune Defic Syndr 2013; 63:307-14. [DOI: 10.1097/qai.0b013e31828ad759] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
72
|
Correlation between cataract grading by Scheimpflug imaging and phaco time in phacoemulsification using peristaltic and venturi pumps. Eur J Ophthalmol 2013; 23:789-92. [PMID: 23640507 DOI: 10.5301/ejo.5000293] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/21/2013] [Indexed: 11/20/2022]
Abstract
PURPOSE To study the correlation among cataract grading system by Scheimpflug imaging (Oculus Pentacam® Nucleus Grading System [PNS]), effective phaco time (EPT), and surgical time (ST) using peristaltic and venturi pumps on the Whitestar Signature Phaco System (Abbott Medical Optics, Inc., Santa Ana, California, USA).
METHODS Patients scheduled to have bimanual microincision phacoemulsification by the same surgeon (T.F.) had Pentacam® Scheimpflug assessment using PNS and were randomly distributed into
2 groups. In group 1, surgery was performed using peristaltic pump, and in group 2, using venturi pump. Parameters assessed in both groups included EPT and ST.
RESULTS Sixty eyes that had uneventful clear cornea phacoemulsification with implantation of foldable intraocular lens (IOL) were evaluated, 30 in each group. The EPT was statistically superior with higher nuclear density grades for both groups 1 and 2 (group 1 Spearman R = 0.739, p<0.001; group 2 Spearman R = 0.924, p<0.001). The ST statistically increased with nucleus density for both groups 1 and 2 (group
1 Spearman R = 0.620, p<0.001; group 2 Spearman R = 0.643, p<0.001). Group 2 presented statistically significant reduction on median ST compared with group 1 for nucleus grading 2, 3, 4, and 5. CONCLUSIONS The PNS is an objective and reproducible method of grading nuclear cataract density and had a correlation with EPT. Peristaltic and venturi pumps in Signature Phaco System were similar in EPT but venturi pump reduced the median ST in nucleus with higher PNS, without repercussion on complications or anterior chamber stability.
Collapse
|
73
|
The eye as a model of ageing in translational research--molecular, epigenetic and clinical aspects. Ageing Res Rev 2013; 12:490-508. [PMID: 23274270 DOI: 10.1016/j.arr.2012.11.002] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2012] [Revised: 11/16/2012] [Accepted: 11/19/2012] [Indexed: 12/13/2022]
Abstract
The eye and visual system are valuable in many areas of translational research such as stem cell therapy, transplantation research and gene therapy. Changes in many ocular tissues can be measured directly, easily and objectively in vivo (e.g. lens transparency; retinal blood vessel calibre; corneal endothelial cell counts) and so the eye may also be a uniquely useful site as a model of ageing. This review details cellular, molecular and epigenetic mechanisms related to ageing within the eye, and describes ocular parameters that can be directly measured clinically and which might be of value in ageing research as the translational "window to the rest of the body". The eye is likely to provide a valuable model for validating biomarkers of ageing at molecular, epigenetic, cellular and clinical levels. A research agenda to definitively establish the relationship between biomarkers of ageing and ocular parameters is proposed.
Collapse
|
74
|
Ni Y, Liu X, Lin Y, Guo X, Wang X, Liu Y. Evaluation of corneal changes with accommodation in young and presbyopic populations using Pentacam High Resolution Scheimpflug system. Clin Exp Ophthalmol 2012; 41:244-50. [DOI: 10.1111/j.1442-9071.2012.02863.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2012] [Accepted: 07/13/2012] [Indexed: 11/30/2022]
Affiliation(s)
- Yao Ni
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology; Sun Yat-Sen University; Guangzhou; China
| | - Xialin Liu
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology; Sun Yat-Sen University; Guangzhou; China
| | - Ying Lin
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology; Sun Yat-Sen University; Guangzhou; China
| | - Xiaobo Guo
- Department of Statistical Science, School of Mathematics and Computational Science; Sun Yat-Sen University; Guangzhou; China
| | - Xueqin Wang
- Department of Statistical Science, School of Mathematics and Computational Science; Sun Yat-Sen University; Guangzhou; China
| | - Yizhi Liu
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology; Sun Yat-Sen University; Guangzhou; China
| |
Collapse
|
75
|
Comprehensive assessment of nuclear and cortical backscatter metrics derived from rotating Scheimpflug images. J Cataract Refract Surg 2012; 38:2100-7. [PMID: 23062740 DOI: 10.1016/j.jcrs.2012.07.033] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2012] [Revised: 07/01/2012] [Accepted: 07/11/2012] [Indexed: 11/23/2022]
Abstract
PURPOSE To quantify cataract in lens-backscatter metrics derived from Pentacam Scheimpflug photographs and determine the most predictive metrics for lens grading and visual performance measures. SETTING Large tertiary referral hospital in South Australia. DESIGN Evaluation of diagnostic test or technology. METHODS In patients attending a cataract clinic between 2005 and 2008, standardized clinical assessments were performed and Scheimpflug photographs taken. Thirteen measures of cataract backscatter were drawn from the images of nuclear and cortical cataract, including new metrics for cortical cataract. The relationships between lens-scatter metrics, visual performance, and lens grades were determined with stepwise multiple linear regression. RESULTS The study enrolled 342 eyes (177 patients). The Lens Opacities Classification System III (LOCS III) nuclear opalescence was best predicted by the average backscatter in the anterior half of the nucleus and the whole nucleus average (r(2) = 0.59). The LOCS III cortical grade was best predicted by the number of slices with significant cortical cataract (r(2) = 0.52), as was Pelli-Robson contrast sensitivity (r(2) = 0.16). Visual acuity was best predicted by the combined anterior half and whole nucleus averages (r(2) = 0.20). Pelli-Robson contrast sensitivity under glare was best predicted by a combination of the anterior half and whole nucleus averages and the calculated percentage of cortical cataract (r(2) = 0.16). CONCLUSIONS Scheimpflug image-derived metrics of nuclear scatter were predictive of visual acuity and contrast sensitivity, whereas metrics of cortical cataract were predictive of visual performance under glare. Automated reporting of cataract severity from Scheimpflug images could be useful clinically and should include measurements of cortical cataract. FINANCIAL DISCLOSURE Neither author has a financial or proprietary interest in any material or method mentioned.
Collapse
|
76
|
Wong SC, Clare G, Bunce C, Sullivan PM, Gregor ZJ, Ezra E. Cataract progression in macular hole cases: results with vitrectomy or with observation. J Cataract Refract Surg 2012; 38:1176-80. [PMID: 22727286 DOI: 10.1016/j.jcrs.2012.02.038] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2011] [Revised: 02/16/2012] [Accepted: 02/16/2012] [Indexed: 10/28/2022]
Abstract
PURPOSE To quantify the difference in progression of nuclear sclerotic cataract using Scheimpflug image analysis in patients with idiopathic full-thickness macular hole who were randomized to have vitrectomy and gas tamponade or to be observed. SETTING Moorfields Eye Hospital, London, United Kingdom. DESIGN Prospective randomized placebo-controlled masked clinical trial. METHODS As part of the Moorfields Macular Hole Study, patients with full-thickness macular hole who were randomized to have vitrectomy and gas tamponade or who were observed were compared. Patients had Scheimpflug image analysis of the crystalline lens to evaluate nuclear sclerosis progression by the single-masked observer at baseline and 3, 6, 9, and 12 months postoperatively. RESULTS Ninety-eight patients had sufficient baseline data for analysis. At 3 months and 6 months, vitrectomy patients had significant increases in nuclear density compared with baseline (16.6% and 33.9%, respectively) (both P<.0001). In the observation group, nuclear density increased by 1.4% between baseline and 6 months (P = .92). At 6 months, the increase in nuclear density from baseline was 24 times greater in the surgical group than in the observation group (P<.0001). No correlation between the rate of nuclear sclerosis progression and age or baseline nuclear density was found. CONCLUSIONS Rapid nuclear sclerosis progression was quantifiable by Scheimpflug image analysis in patients having surgery for idiopathic full-thickness macular hole.There was no [corrected] evidence of a correlation between age groups and the rate of cataract progression. FINANCIAL DISCLOSURE No author has a financial or proprietary interest in any material or method mentioned.
Collapse
Affiliation(s)
- S Chien Wong
- Vitreoretinal Department, Moorfields Eye Hospital, London, United Kingdom
| | | | | | | | | | | |
Collapse
|
77
|
Kim EK, Jo KJ, Joo CK. Comparison of tips in coaxial microincision cataract surgery with the bevel-down technique. J Cataract Refract Surg 2011; 37:2028-33. [DOI: 10.1016/j.jcrs.2011.05.038] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2010] [Revised: 05/14/2011] [Accepted: 05/17/2011] [Indexed: 11/16/2022]
|
78
|
Charalampidou S, Nolan J, Loughman J, Stack J, Higgins G, Cassidy L, Beatty S. Psychophysical impact and optical and morphological characteristics of symptomatic non-advanced cataract. Eye (Lond) 2011; 25:1147-54. [PMID: 21660066 DOI: 10.1038/eye.2011.123] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
PURPOSE To investigate whether psychophysical, morphological, and/or optical characteristics of symptomatic non-advanced cataract are complementary to, or more appropriate than, visual acuity (VA) for the purposes of recording visual data that reflect subjective visual difficulty in patients with cataract that exhibit relative sparing of high contrast acuity (0.4 logarithm of minimal angle of resolution (logMAR) scale or better). METHODS Eighty-two patients with symptomatic non-advanced cataract and no other ocular pathology were asked to complete a validated questionnaire, and to perform a series of visual function assessments including: corrected distance VA (CDVA); photopic and mesopic contrast sensitivity; photopic and mesopic glare disability (GD); reading acuity and reading speed; stereoacuity; and retinal sensitivity. Optical and morphological characteristics of the cataract were evaluated by lens optical density and by the Lens Opacities Classification System III, respectively. Correlations between questionnaire score and each of these measures were calculated. RESULTS Statistically significant negative correlations were observed between the Rasch-scaled questionnaire score and mesopic GD (at 3 and 6 cycles per degree (cpd); r=-0.396 (P<0.01) and -0.451 (P<0.05), respectively) and between the Rasch-scaled questionnaire score and photopic GD (at 3 and 6 cpd; r=-0.328 (P<0.01) and -0.440 (P<0.01), respectively). CONCLUSION Symptomatic non-advanced cataract, in the presence of good CDVA, is associated with measurable subjective visual difficulty, best reflected in a decrease in mesopic and photopic GD (at medium spatial frequencies). CDVA does not reflect the patient's visual dissatisfaction in such cases.
Collapse
Affiliation(s)
- S Charalampidou
- Institute of Eye Surgery, Whitfield Clinic, Waterford, Ireland.
| | | | | | | | | | | | | |
Collapse
|
79
|
Takacs AI, Mihaltz K, Nagy ZZ. Corneal Density with the Pentacam After Photorefractive Keratectomy. J Refract Surg 2011; 27:269-77. [DOI: 10.3928/1081597x-20100618-02] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2009] [Accepted: 05/28/2010] [Indexed: 11/20/2022]
|
80
|
Chen Y, Bao YZ, Pei XT. Morphologic changes in the anterior chamber in patients with cortical or nuclear age-related cataract. J Cataract Refract Surg 2011; 37:77-82. [PMID: 21183102 DOI: 10.1016/j.jcrs.2010.07.029] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2010] [Revised: 07/15/2010] [Accepted: 07/15/2010] [Indexed: 11/18/2022]
Abstract
PURPOSE To assess and compare the morphologic changes in the anterior segment in eyes with nuclear or cortical age-related cataract using Scheimpflug imaging. SETTING Peking University People's Hospital, Beijing, China. DESIGN Case-control study. METHODS Patients with nuclear or cortical age-related cataract were recruited. The grade of nuclear opalescence or cortical opacity was assessed using the Lens Opacities Classification System III (LOCS III). A group of elderly subjects with a clear lens and normal vision served as the control group. Anterior chamber depth (ACD), anterior chamber volume (ACV), and lens thickness were evaluated using Scheimpflug imaging (Pentacam). RESULTS Two hundred sixty-nine patients (330 eyes) were recruited. Thirty eyes were enrolled for each nuclear opalescence and cortical grade. The control group comprised 30 eyes (19 subjects). In eyes with age-related cataract, lens thickness increased with an increase in cortical opacity, whereas the ACD and ACV values decreased. The ACD was inversely correlated with LOCS III grades for nuclear opalescence (r = -0.197, P = .004), nuclear color (r = -0.195, P = .005), and cortical opacity (r = -0.508, P<.005). There were significant differences in lens thickness, ACD, and ACV between nuclear color, nuclear opalescence, and cortical opacity for LOCS III grades 3, 4, and 5, respectively. CONCLUSIONS There were significant differences in lens thickness, ACD, and ACV between nuclear and cortical age-related cataracts. The ACD decreased more in eyes with cortical cataract, suggesting that the risk for angle-closure glaucoma may be greater in cases of cortical opacity in which lens expansion is greater. FINANCIAL DISCLOSURE No author has a financial or proprietary interest in any material or method mentioned.
Collapse
Affiliation(s)
- Yi Chen
- People Eye Center, Peking University People's Hospital, and Key Laboratory of Vision Loss and Restoration, Ministry of Education, Beijing, China
| | | | | |
Collapse
|
81
|
|
82
|
Ni Y, Liu XL, Wu MX, Lin Y, Sun YY, He C, Liu YZ. Objective evaluation of the changes in the crystalline lens during accommodation in young and presbyopic populations using Pentacam HR system. Int J Ophthalmol 2011; 4:611-5. [PMID: 22553730 DOI: 10.3980/j.issn.2222-3959.2011.06.07] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2011] [Accepted: 10/31/2011] [Indexed: 11/02/2022] Open
Abstract
AIM To quantify the changes in the lens profile with accommodation in different age groups. METHODS The Pentacam HR system was used to obtain the images of the anterior eye segment from 23 young and 15 presbyopic emmetropic subjects in unaccommodated (with an accommodation stimulus of 0.0D) and accommodated (with an accommodation stimulus of 5.0D for the young group and 1.0D for the presbyopic group) states. The phakic crystalline lens shape, including curvature of crystalline lens and central lens thickness (CLT), and the measurements of anterior segment length (ASL), central anterior chamber depth (CACD) were investigated. The anterior chamber volume (ACV) was also measured. RESULTS The reduction of CACD and ACV were significant in both groups after accommodation stimulus. From the profile of anterior eye segment, a significant decrease in anterior crystalline lens radii of curvature (-2.52mm) and a mean increase in CLT (0.222mm) and ASL (0.108mm) were found in the young group with an accommodation stimulus of 5.0D. However, no statistically significant changes of CLT, ASL, or crystalline lens radii of curvature were found in the presbyopic group. CONCLUSION Our data showed that the shallowing of anterior chamber during accommodation was caused by the forward bulging of the anterior lens surface, rather than by anterior shifting of lens position in either young or presbyopic subjects.
Collapse
Affiliation(s)
- Yao Ni
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Sun Yat-sen University, Guangzhou 510060, Guangdong Province, China
| | | | | | | | | | | | | |
Collapse
|
83
|
Cho YK, Chang HS, La TY, Ji D, Kim H, Choi JA, Kim MS. Anterior segment parameters using Pentacam and prediction of corneal endothelial cell loss after cataract surgery. KOREAN JOURNAL OF OPHTHALMOLOGY 2010; 24:284-90. [PMID: 21052508 PMCID: PMC2955271 DOI: 10.3341/kjo.2010.24.5.284] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2009] [Accepted: 05/16/2010] [Indexed: 12/04/2022] Open
Abstract
Purpose We evaluated various preoperative anterior segment parameters measured with a Pentacam rotating Scheimpflug camera and compared them with those of conventional methods. We also evaluated the effect of different parameters on corneal endothelial cells after cataract surgery. Methods Pentacam examination was performed in 88 eyes from 88 patients to evaluate central anterior chamber depth (ACDpentacam), nuclear density (Densitometrypentacam), anterior chamber volume (ACV), and lens thickness (LTpentacam). We compared values of ACDpentacam with those of ultrasound (ACDsono) and also compared Densitometrypentacam values with those of Lens Opacities Classification System (LOCS III) classification. We evaluated the effect of the following preoperative values measured with Pentacam on postoperative endothelial cell loss: pupil size measured both preoperatively and before capsulorrhexsis (PupilCCC), amount of viscoelastics, and LT measured by ultrasound (LTsono). Results A significant concordance was found between the two grading methods of nuclear opacity: Densitometrypentacam and LOCS III classification (τb = 0.414, p = 0.000). We also found a positive correlation between ACDpentacam and ACDsono (r = 0.823, p = 0.000) and between ACDpentacam and ACV (r = 0.650, p = 0.000). There were significant differences between the results of LTpentacam and LTsono. The final regression model identified Densitometrypentacam, viscoelastics and PupilCCC as independent predictors of decreased postoperative corneal endothelial cell density (CD) at postoperative day 3, and Densitometrypentacam, viscoelastics, and ACV as independent predictors of decreased CD two months postoperatively (p<0.05). Conclusions Good agreement was found between all results obtained with the Pentacam and conventional methods except LT. Analyzing anterior chamber parameters preoperatively using Pentacam could be helpful to predict postoperative endothelial cell loss.
Collapse
Affiliation(s)
- Yang Kyeung Cho
- Department of Ophthalmology, St. Vincent's Hospital, The Catholic University of Korea School of Medicine, Suwon, Korea
| | | | | | | | | | | | | |
Collapse
|
84
|
Mitomycin C Does Not Inhibit Exacerbation of Granular Corneal Dystrophy Type II Induced by Refractive Surface Ablation. Cornea 2010; 29:490-6. [DOI: 10.1097/ico.0b013e3181c3258a] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
85
|
Nixon DR. Preoperative cataract grading by Scheimpflug imaging and effect on operative fluidics and phacoemulsification energy. J Cataract Refract Surg 2010; 36:242-6. [DOI: 10.1016/j.jcrs.2009.08.032] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2009] [Revised: 08/26/2009] [Accepted: 08/27/2009] [Indexed: 10/19/2022]
|
86
|
Chikamoto N, Fujitsu Y, Kimura K, Nishida T, Araki T. Device for cataract analysis: Development and relevance to cataract surgery. J Cataract Refract Surg 2010; 36:58-65. [DOI: 10.1016/j.jcrs.2009.06.032] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2009] [Revised: 06/05/2009] [Accepted: 06/05/2009] [Indexed: 10/20/2022]
|
87
|
Kirkwood BJ, Hendicott PL, Read SA, Pesudovs K. Repeatability and validity of lens densitometry measured with Scheimpflug imaging. J Cataract Refract Surg 2009; 35:1210-5. [PMID: 19545810 DOI: 10.1016/j.jcrs.2009.03.017] [Citation(s) in RCA: 68] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2008] [Revised: 03/25/2009] [Accepted: 03/26/2009] [Indexed: 11/17/2022]
Abstract
PURPOSE To assess the repeatability and validity of lens densitometry derived from the Pentacam Scheimpflug imaging system. SETTING Eye Clinic, Queensland University of Technology, Brisbane, Australia. METHODS This prospective cross-sectional study evaluated 1 eye of subjects with or without cataract. Scheimpflug measurements and slitlamp and retroillumination photographs were taken through a dilated pupil. Lenses were graded with the Lens Opacities Classification System III. Intraobserver and interobserver reliability of 3 observers performing 3 repeated Scheimpflug lens densitometry measurements each was assessed. Three lens densitometry metrics were evaluated: linear, for which a line was drawn through the visual axis and a mean lens densitometry value given; peak, which is the point at which lens densitometry is greatest on the densitogram; 3-dimensional (3D), in which a fixed, circular 3.0 mm area of the lens is selected and a mean lens densitometry value given. Bland and Altman analysis of repeatability for multiple measures was applied; results were reported as the repeatability coefficient and relative repeatability (RR). RESULTS Twenty eyes were evaluated. Repeatability was high. Overall, interobserver repeatability was marginally lower than intraobserver repeatability. The peak was the least reliable metric (RR 37.31%) and 3D, the most reliable (RR 5.88%). Intraobserver and interobserver lens densitometry values in the cataract group were slightly less repeatable than in the noncataract group. CONCLUSION The intraobserver and interobserver repeatability of Scheimpflug lens densitometry was high in eyes with cataract and eyes without cataract, which supports the use of automated lens density scoring using the Scheimpflug system evaluated in the study.
Collapse
Affiliation(s)
- Bradley J Kirkwood
- School of Optometry, Queensland University of Technology, Brisbane, Australia.
| | | | | | | |
Collapse
|
88
|
Kim JS, Chung SH, Joo CK. Clinical application of a Scheimpflug system for lens density measurements in phacoemulsification. J Cataract Refract Surg 2009; 35:1204-9. [PMID: 19545809 DOI: 10.1016/j.jcrs.2009.02.032] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2008] [Revised: 02/21/2009] [Accepted: 02/23/2009] [Indexed: 11/27/2022]
Abstract
PURPOSE To evaluate the relationship between lens density measured using the Pentacam Scheimpflug system and phacodynamics (phacoemulsification time, phacoemulsification energy, and balanced salt solution [BSS] use) in patients with age-related nuclear cataract. SETTING Department of Ophthalmology and Visual Science, Kangnam St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea. METHODS This prospective observer-masked study was of eyes with age-related nuclear cataract. Objective lens density (0 to 100 points) was determined using the Scheimpflug system. Subjective grading was by the Lens Opacities Classification System III (LOCS III). The correlations between lens density values and phacoemulsification time, phacoemulsification energy, and BSS use were analyzed prospectively. RESULTS Fifty-three patients (60 eyes) were evaluated. The mean Scheimpflug-measured lens nuclear density was 14.71 +/- 6.12 (SD). There was a positive linear correlation between the Scheimpflug-measured lens nuclear density and the LOCS III grading scores for nuclear opalescence (NO) and nuclear color (NC) (r = 0.734 and 0.719, respectively; both P<.05). The Scheimpflug-measured lens nuclear density correlated with torsional amplitude, time, and cumulated dissipated energy (CDE) (P<.05), but not with BSS use (P = .195). The CDE was more strongly correlated with Scheimpflug-measured lens nuclear density (r = 0.797) than with LOCS III NO or NC scores (r = 0.614 and r = 0.637, respectively). CONCLUSIONS Scheimpflug-measured lens nuclear density correlated with phacoemulsification time and energy. The Scheimpflug system enabled quantitative cataract grading and may help predict phacodynamics in cataract surgery.
Collapse
Affiliation(s)
- Jung-Sub Kim
- Department of Ophthalmology and Visual Science, Kangnam St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | | | | |
Collapse
|
89
|
Ainsbury EA, Bouffler SD, Dörr W, Graw J, Muirhead CR, Edwards AA, Cooper J. Radiation cataractogenesis: a review of recent studies. Radiat Res 2009; 172:1-9. [PMID: 19580502 DOI: 10.1667/rr1688.1] [Citation(s) in RCA: 253] [Impact Index Per Article: 15.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
The lens of the eye is recognized as one of the most radiosensitive tissues in the human body, and it is known that cataracts can be induced by acute doses of less than 2 Gy of low-LET ionizing radiation and less than 5 Gy of protracted radiation. Although much work has been carried out in this area, the exact mechanisms of radiation cataractogenesis are still not fully understood. In particular, the question of the threshold dose for cataract development is not resolved. Cataracts have been classified as a deterministic effect of radiation exposure with a threshold of approximately 2 Gy. Here we review the combined results of recent mechanistic and human studies regarding induction of cataracts by ionizing radiation. These studies indicate that the threshold for cataract development is certainly less than was previously estimated, of the order of 0.5 Gy, or that radiation cataractogenesis may in fact be more accurately described by a linear, no-threshold model.
Collapse
Affiliation(s)
- E A Ainsbury
- Health Protection Agency, Radiation Protection Division, Centre for Radiation, Chemical and Environmental Hazards, Chilton, Didcot, Oxfordshire OX11 0RQ, United Kingdom.
| | | | | | | | | | | | | |
Collapse
|
90
|
Grewal DS, Brar GS, Grewal SPS. Correlation of nuclear cataract lens density using Scheimpflug images with Lens Opacities Classification System III and visual function. Ophthalmology 2009; 116:1436-43. [PMID: 19500847 DOI: 10.1016/j.ophtha.2009.03.002] [Citation(s) in RCA: 105] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2008] [Revised: 03/03/2009] [Accepted: 03/03/2009] [Indexed: 10/20/2022] Open
Abstract
PURPOSE To calculate the average lens density (ALD) and nuclear lens density (NLD) using Scheimpflug images and to determine their correlation with logarithmic minimal angle resolution (logMAR) best-corrected visual acuity (BCVA), contrast sensitivity (CS), and lens grading based on the Lens Opacities Classification System (LOCS) III. DESIGN Cross-sectional observational study. PARTICIPANTS One hundred ten patients with age-related nuclear cataract. METHODS The logMAR BCVA was recorded using Early Treatment Diabetic Retinopathy Study charts and photopic contrast-sensitivity using CSV-1000LV (Vector Vision, Greeneville, OH). Fifty Scheimpflug images (Pentacam, Oculus, Germany) covering 360 degrees of the lens were obtained for 1 eye of each patient after dilation. All Scheimpflug images were exported to ImageJ software (NIH, Bethesda, MD) for analysis wherein the ALD and NLD (using a mask applied to the lens nuclear area) were calculated in pixel-intensity units. Repeatability was determined using coefficient of variation (CoV) and intraclass correlation coefficient (ICC). Lens opacity on slit-lamp images was graded using LOCS III for nuclear opalescence (NO) and nuclear color (NC). MAIN OUTCOME MEASURES We evaluated ALD and NLD on Scheimpflug images and their correlation with NO and NC LOCS III grading, BCVA, and photopic CS. RESULTS The ICC for ALD and NLD were 0.983 and 0.99, respectively; the CoV were 3.92+/-1.76% and 2.57+/-0.74%, respectively. The ALD correlated with NO (r = .774; P<0.001), NC (r = .732; P<0.001), BCVA (r = 0.696; P<0.001), and CS at 3 cycles per degree CPD (P = 0.011), 6, 12, and 18 CPD (P<0.001). The NLD correlated with NO (r = .859; P<0.001), NC (r = .81; P<0.001), BCVA (r = .760; P<0.001), CS at 3 CPD (P = 0.002), 6, 12, and 18 CPD (P<0.001). The NLD had a significantly stronger correlation with BCVA (P<0.05), NO (P<0.01), NC (P<0.01), and CS at 6 CPD (P<0.01) and 12 CPD (P<0.005) compared with ALD. CONCLUSIONS Repeatable 360 degrees lens density measurements were obtained using Scheimpflug imaging. A stronger correlation was observed between NLD and LOCS III grading, BCVA, and photopic CS than with ALD. The NLD is an objective and repeatable method for assessment of lens density, which could be helpful in longitudinal studies monitoring nuclear cataracts.
Collapse
|
91
|
Wegener A, Laser-Junga H. Photography of the anterior eye segment according to Scheimpflug's principle: options and limitations - a review. Clin Exp Ophthalmol 2009; 37:144-54. [DOI: 10.1111/j.1442-9071.2009.02018.x] [Citation(s) in RCA: 96] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|