Hochleitner M, Hörtnagl H, Hörtnagl H, Fridrich L, Gschnitzer F. Long-term efficacy of physiologic dual-chamber pacing in the treatment of end-stage idiopathic dilated cardiomyopathy. Am J Cardiol 1992; 70:1320-5. [PMID: 1442585 DOI: 10.1016/0002-9149(92)90769-u] [Citation(s) in RCA: 139] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
The long-term efficacy of physiologic dual-chamber (DDD) pacing in the treatment of end-stage idiopathic dilated cardiomyopathy was evaluated in a longitudinal study of up to 5 years in 17 patients. The considerable clinical improvement achieved after implantation of a pacemaker programmed for DDD pacing at an atrioventricular delay of 100 ms was maintained throughout the follow-up period or until death and was associated with a consistent decrease in New York Heart Association class and an increase in left ventricular ejection fraction. Cardiothoracic ratio, heart rate and echocardiographic dimensions progressively decreased, and systolic and diastolic blood pressures increased. Median survival time was 22 months. During follow-up, 4 patients received donor hearts, 9 had a sudden death at home without defined cause or after a thromboembolic event, and 1 died from adenocarcinoma. Three patients survived the follow-up. No patient needed rehospitalization owing to a worsening of heart failure after pacemaker implantation. An interruption of pacing in DDD mode for 2 to 4 hours was followed within the first months by a marked decrease in left ventricular ejection fraction and an increase in cardiothoracic ratio and echocardiographic dimensions, but this response consistently decreased during follow-up. The data indicate that DDD pacing can be recommended as a useful tool in the long-term treatment of end-stage idiopathic dilated cardiomyopathy, with progressive improvement in cardiac function and a reduction of the dilatation of the left ventricle.
Collapse
Affiliation(s)
- M Hochleitner
- Department of Medicine, University of Innsbruck, Austria
| | | | | | | | | |
Collapse
|
52
|
Linde-Edelstam CM, Juhlin-Dannfelt A, Nordlander R, Pehrsson SK. The hemodynamic importance of atrial systole: a function of the kinetic energy of blood flow? Pacing Clin Electrophysiol 1992; 15:1740-9. [PMID: 1279542 DOI: 10.1111/j.1540-8159.1992.tb02962.x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
The relative importance of atrial systole on left ventricular filling was investigated at rest and during exercise in 25 patients with dual chamber pacemakers. The mean blood flow velocity over the mitral valve, the velocities of the rapid filling phase (E), the active filling phase (A), and the E/A ratio were determined by pulsed Doppler-echocardiography. The patients were first examined at rest during AV sequential pacing (DVI) at 70 and 104 beats/min. The investigation was subsequently repeated during atrial synchronous pacing (VDD) at rest and during supine submaximal exercise at workloads adjusted to achieve heart rates corresponding to those during DVI pacing. The mean blood flow velocity at rest did not differ between DVI and VDD pacing at 70 beats/min (0.46 vs 0.49 m/sec). When the resting heart rate was increased to 104 beats/min (DVI) the mean blood flow velocity increased to 0.56 msec (P < 0.001). At a corresponding heart rate during exercise (VDD) the velocity increased to 0.70 msec (P < 0.001). At a resting heart rate of 70 beats/min the E/A ratio (n = 14) did not differ significantly between DVI and VDD pacing. With an increased resting heart rate (DVI) the E/A ratio decreased from 0.94 +/- 0.45 to 0.78 +/- 0.18; NS. When the heart rate increased during exercise (VDD) the E/A ratio increased from 0.75 +/- 0.14 to 0.97 +/- 0.16; P < 0.001. There was a positive correlation between the increase of the mean blood flow velocity and the increase of the E/A ratio during exercise (r = 0.69, P < 0.01). No such correlation was found when the heart rate was changed at rest. Thus, the importance of atrial systole on ventricular filling diminishes during exercise in accordance with increasing blood flow velocity, which by physical principles is related to the kinetic energy. The relative importance of atrial systole is hence inversely correlated to the kinetic energy of the blood flow.
Collapse
|
53
|
Capucci A, Boriani G, Specchia S, Marinelli M, Santarelli A, Magnani B. Evaluation by cardiopulmonary exercise test of DDDR versus DDD pacing. Pacing Clin Electrophysiol 1992; 15:1908-13. [PMID: 1279570 DOI: 10.1111/j.1540-8159.1992.tb02992.x] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
UNLABELLED In eight patients (age 62 +/- 6 years) a DDDR pacemaker was implanted for sick sinus syndrome (three cases) or second- and third-degree AV block (five cases). In five subjects chronotropic incompetence (maximal heart rate on effort < 110 beats/min) was present before implantation. One month after implantation the patients were randomized to DDDR or DDD pacing for 3 weeks each, with subsequent crossover, and at the end of each period a symptom limited cardiopulmonary exercise test (25 watts/2 min) was performed and the patients were requested to fill a symptoms questionnaire. RESULTS DDDR pacing, compared to DDD, was associated with higher maximal heart rates (127 +/- 20 vs 110 +/- 27 beats/min, P < 0.02), higher [VO2 max (25.4 +/- 6.1 vs 21.5 +/- 7.8 mL/kg/per min, P < 0.03) and higher VO2 at the anaerobic threshold (20.3 +/- 5.0 vs 15.8 +/- 4.9 mL/kg per min, P < 0.03), without significant differences in mean exercise time (526 +/- 193 vs 472 +/- 216 sec, NS). The increase in VO2 max obtained in DDDR versus DDD was significantly related to the increase in maximal heart rate (r = 0.72, P < 0.05) and the increase in VO2 at the anaerobic threshold obtained in DDDR versus DDD was related to the increase in heart rate at the anaerobic threshold (r = 0.81, P < 0.02).(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- A Capucci
- Institute of Cardiovascular Diseases, University of Bologna, Italy
| | | | | | | | | | | |
Collapse
|
54
|
Jutzy RV, Feenstra L, Pai R, Florio J, Bansal R, Aybar R, Levine PA. Comparison of intrinsic versus paced ventricular function. Pacing Clin Electrophysiol 1992; 15:1919-22. [PMID: 1279572 DOI: 10.1111/j.1540-8159.1992.tb02994.x] [Citation(s) in RCA: 22] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
UNLABELLED There is increasing evidence supporting the benefits of providing optimum AV delay in cardiac pacing, though controversy exists regarding its value and the benefits of intrinsic versus paced ventricular activation. This study compared various AV delays at rest in patients whose native AV delays were > or = 200 msec. Only patients with DDD pacemakers who had intact AV conduction and normal ventricular activation were included in the study. Nine patients were studied. METHODS Ten studies were performed. Evaluation was done in AAI and DDD modes at paced heart rates of 60/min or as close as possible to the intrinsic heart rate if this was > 60/min. Stroke volume (SV) and cardiac output (CO) were measured. RESULTS When AV sequential pacing in the DDD mode with an optimum AV delay was compared to AAI pacing with a prolonged AV interval, the average optimum AV delay in the DDD mode was 157 msec and ranged from 125 to 175 msec. The average AV interval in the AAI mode was 245 msec and ranged from 212 to 300 msec. In the DDD mode, there was an overall significant improvement in CO of 11% and SV of 9%. Patients with intrinsic AV conduction times of > 220 msec showed an overall significant improvement in CO of 13% and SV of 11%. In patients with intrinsic AV conduction times of < 220 msec, an improvement in CO of 6% and SV of 4% was seen. CONCLUSIONS (1) An optimum AV delay is an important component of hemodynamic performance; and (2) AV sequential pacing at rest with an optimum AV delay may provide better hemodynamic performance than atrial pacing with intrinsic ventricular conduction when native AV conduction is prolonged > 220 msec.
Collapse
Affiliation(s)
- R V Jutzy
- Section of Cardiology, Loma Linda University Medical Center, California 92354
| | | | | | | | | | | | | |
Collapse
|
55
|
|
56
|
Lau CP, Tai YT, Fong PC, Li JP, Chung FL. Atrial arrhythmia management with sensor controlled atrial refractory period and automatic mode switching in patients with minute ventilation sensing dual chamber rate adaptive pacemakers. Pacing Clin Electrophysiol 1992; 15:1504-14. [PMID: 1383962 DOI: 10.1111/j.1540-8159.1992.tb02924.x] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Although a long postventricular atrial refractory period (PVARP) may prevent the occurrence of pacemaker mediated tachycardias and inadvertent tracking of atrial arrhythmias in dual chamber (DDD) pacing, the maximum upper rate will necessarily be compromised. We tested the feasibility of using minute ventilation sensing in a dual chamber rate adaptive pacemaker (DDDR) to shorten the PVARP during exercise in 13 patients with bradycardias (resting PVARP = 463 +/- 29 msec) to avoid premature upper rate behavior. Graded treadmill exercise tests in the DDD and DDDR modes at this PVARP resulted in maximum ventricular rates of 98 +/- 8 and 142 +/- 3 beats/min, respectively (P < 0.0001), due to chronotropic incompetence and upper rate limitation in the DDD mode, both circumvened with the use of sensor. In order to stimulate atrial arrhythmias, chest wall stimulation was applied for 30 seconds at a rate of 250 beats/min at a mean unipolar atrial sensitivity of 0.82 mV. Irregular ventricular responses occurred in the DDD mode (the rates at a PVARP of 280 and 463 +/- 29 msec were, respectively 92 +/- 5 and 66 +/- 3 msec; P < 0.0001). In the DDDR mode at a PVARP of 463 +/- 29 msec, regular ventricular pacing at 53 +/- 2 beats/min occurred due to mode switching to VVIR mode in the presence of repetitive sensed atrial events within the PVARP. One patient developed spontaneous atrial fibrillation on follow-up, which was correctly identified by the pacemaker algorithm, resulting in mode switch from DDDR to regular VVIR pacing and preservation of rate response. In conclusion, sensor controlled PVARP allows a long PVARP to be used at rest without limiting the maximum rate during exercise. In addition, to offer protection against retrograde conduction, a long PVARP and mode switching also limit the rate during atrial arrhythmias and allow regular ventricular rate responses according to the physiological demands.
Collapse
Affiliation(s)
- C P Lau
- Department of Medicine, University of Hong Kong, Queen Mary Hospital
| | | | | | | | | |
Collapse
|
57
|
Parry G, Malbut K, Dark JH, Bexton RS. Optimal pacing modes after cardiac transplantation: is synchronisation of recipient and donor atria beneficial? Heart 1992; 68:195-8. [PMID: 1389737 PMCID: PMC1025014 DOI: 10.1136/hrt.68.8.195] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
OBJECTIVE To investigate the response of the transplanted heart to different pacing modes and to synchronisation of the recipient and donor atria in terms of cardiac output at rest. DESIGN Doppler derived cardiac output measurements at three pacing rates (90/min, 110/min and 130/min) in five pacing modes: right ventricular pacing, donor atrial pacing, recipient-donor synchronous pacing, donor atrial-ventricular sequential pacing, and synchronous recipient-donor atrial-ventricular sequential pacing. PATIENTS 11 healthy cardiac transplant recipients with three pairs of epicardial leads inserted at transplantation. RESULTS Donor atrial pacing (+11% overall) and donor atrial-ventricular sequential pacing (+8% overall) were significantly better than right ventricular pacing (p < 0.001) at all pacing rates. Synchronised pacing of recipient and donor atrial segments did not confer additional benefit in either atrial or atrial-ventricular sequential modes of pacing in terms of cardiac output at rest at these fixed rates. CONCLUSIONS Atrial pacing or atrial-ventricular sequential pacing appear to be appropriate modes in cardiac transplant recipients. Synchronisation of recipient and donor atrial segments in this study produced no additional benefit. Chronotropic competence in these patients may, however, result in improved exercise capacity and deserves further investigation.
Collapse
Affiliation(s)
- G Parry
- Department of Cardiology, Freeman Hospital, Newcastle upon Tyne
| | | | | | | |
Collapse
|
58
|
Abstract
Advances in cardiac pacing continue at an astounding rate, and, occasionally, technologic capabilities are developed almost faster than they can be implemented clinically. The development and implementation of single- and dual-chamber rate-adaptive pacemakers have been the major thrusts in cardiac pacing in recent years. Rate-adaptive pacing will continue to be of primary interest in the future as investigators search for the perfect "sensor" and attempt to develop rate-adaptive pacemakers with multiple sensors. The "smart" pacemaker--that is, an autoprogramming, autodiagnostic device--will also be refined. The ultimate "smart" pacemaker would be capable of automatically adjusting output and sensing factors as well as altering the rate-adaptive variables and even changing the pacing mode in response to variations in the underlying rhythm. Other aspects of cardiac pacing that will be actively investigated include new low-threshold pacing lead designs, refinements of the single-lead pacing system capable of P-synchronous pacing, and diagnostic information that can be derived from sensors used for rate-adaptive pacing.
Collapse
Affiliation(s)
- D L Hayes
- Division of Cardiovascular Diseases and Internal Medicine, Mayo Clinic, Rochester, MN 55905
| |
Collapse
|
59
|
Lau CP, Tai YT, Fong PC, Li JP, Leung SK, Chung FL, Song S. Clinical Experience with an Activity Sensing DDDR Pacemaker Using an Accelerometer Sensor. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 1992; 15:334-43. [PMID: 1372728 DOI: 10.1111/j.1540-8159.1992.tb06503.x] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
The rate adaptive characteristics and pacemaker mediated tachycardia protection algorithm of an accelerometer based DDDR pacemaker were evaluated in 11 patients with bradycardia (seven atrioventricular block, four sick sinus syndrome). Rate adaptive programming was effected by collecting the acceleration level during a 3-minute moderate exercise ("tailoring" of sensor). In comparison with an externally attached piezoelectric sensor, the accelerometer sensor showed lower rate changes during external tapping of the pacemaker (16 +/- 3 vs 29 +/- 4 ppm, P less than 0.02) and applied direct pressure (1 +/- 1 vs 40 +/- 3 beats/min, P less than 0.001) on the pacemaker. At nominal setting, the accelerometer sensor showed improved rate stability and higher rate response to jogging and standing, although responses to other daily activities and treadmill exercise were similar. Apart from changing the rate responsive slope, rate response could be improved by repeat "tailoring" of the sensor at a lower exercise level, resulting in better overall rate response characteristics. The ability of the rate monitoring software to collect acceleration levels for an activity and profile the projected rate response at different rate responsive settings allowed programming to be effected with the minimum amount of exercise testing. The pacemaker also discriminated atrial tachyarrhythmias from normal sinus response using the sensor to judge the appropriateness of the atrial rate, which correctly identified and prevented rapid ventricular tracking in two patients during atrial flutter/fibrillation.
Collapse
Affiliation(s)
- C P Lau
- Department of Medicine, University of Hong Kong, Queen Mary Hospital
| | | | | | | | | | | | | |
Collapse
|
60
|
Jutzy RV, Florio J, Isaeff DM, Feenstra L, Briggs B, Levine PA. Limitations of testing methods for evaluation of dual chamber versus single chamber adaptive rate pacing. Am J Cardiol 1991; 68:1715-7. [PMID: 1746477 DOI: 10.1016/0002-9149(91)90335-i] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Affiliation(s)
- R V Jutzy
- Section of Cardiology, Loma Linda University Medical Center, California 92354
| | | | | | | | | | | |
Collapse
|
61
|
Abstract
The interest in VDD pacemakers has been renewed by the introduction of single-pass leads, and continuing modifications and technical developments promise significant improvement. However, convincing long-term data confirming the reliability and the use of newer leads are not yet available. Compared with VVIR pacemakers VDD pacing has theoretical advantages over the VVIR mode, offering better hemodynamic and endocrine responses. However, its range of indications is narrow and rate adaptation is essential when sinus node chronotropic inadequacy is present or likely to occur. In addition, on certain occasions a VDD pacemaker may not maintain persistent atrial-synchronous pacing, thus necessitating the use of a DDD unit.
Collapse
Affiliation(s)
- D Katritsis
- Department of Cardiological Sciences, St. George's Hospital Medical School, London, England
| | | |
Collapse
|
62
|
Abstract
Advances have been made rapidly in the field of cardiac pacing. The most significant technologic advance is that of pacemakers capable of rate-adaptive pacing. Multiple types of sensors are now used for rate-adaptive pacing; some are commercially available and many are undergoing clinical investigation. In the near future, clinical investigation will begin on pacemakers that incorporate dual simultaneous sensors for rate-adaptive pacing. Significant improvement has been made in electrode design. Electrodes with low thresholds allow improved battery longevity. Steroid-eluting leads have proven reliable and capable of avoiding the early threshold rise seen with other electrodes. Standardization of pacemaker connector dimensions is now under way. The International Standards Organization has established the guidelines for connector standardization, and the guidelines have been adopted by the major manufacturers. The ultimate "smart" pacemaker would be capable of autoprogramming most or all of its programmable features. Many autoprogramming features have already been incorporated, and several others such as automatic programming of output and sensitivity are under investigation.
Collapse
Affiliation(s)
- D L Hayes
- Division of Cardiovascular Diseases and Internal Medicine, Mayo Clinic, Rochester, Minnesota 55905
| |
Collapse
|
63
|
Hoeschen RJ, Reimold SC, Lee RT, Plappert TJ, Lamas GA. The effect of posture on the response to atrioventricular synchronous pacing in patients with underlying cardiovascular disease. Pacing Clin Electrophysiol 1991; 14:756-9. [PMID: 1712948 DOI: 10.1111/j.1540-8159.1991.tb04101.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
In order to determine whether the hemodynamic benefit of atrioventricular synchronous pacing is maintained in the upright position, 14 patients with dual chamber pacemakers were paced in VVI mode and DDD mode in both the supine and standing position. The hemodynamic response was assessed by measuring the velocity time integral derived from the pulsed-wave Doppler signal in the left ventricular outflow tract during VVI pacing and dual chamber pacing at three different AV delays (125, 200, 250 ms). In the supine position, the velocity time integral during VVI pacing was 14.6 +/- 3.0 cm and this increased during DDD pacing at all three AV delays (17.7 +/- 3.3, 17.9 +/- 3.0, 17.5 +/- 3.5 cm). In the upright position, the velocity time integral during VVI pacing was 12.9 +/- 3.5 cm and this increased with DDD pacing (15.5 +/- 3.3, 15.1 +/- 4.0, 15.1 +/- 3.9 cm). It was concluded that although stroke volume decreases when assuming the upright position, the beneficial response to dual chamber pacing is maintained and equals that observed in the supine position.
Collapse
Affiliation(s)
- R J Hoeschen
- University of Manitoba, St. Boniface General Hospital, Winnipeg, Canada
| | | | | | | | | |
Collapse
|
64
|
Oldroyd KG, Rae AP, Carter R, Wingate C, Cobbe SM. Double blind crossover comparison of the effects of dual chamber pacing (DDD) and ventricular rate adaptive (VVIR) pacing on neuroendocrine variables, exercise performance, and symptoms in complete heart block. Heart 1991; 65:188-93. [PMID: 1827588 PMCID: PMC1024577 DOI: 10.1136/hrt.65.4.188] [Citation(s) in RCA: 55] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
OBJECTIVE To compare the effects of dual chamber pacing (DDD) and ventricular rate adaptive pacing (activity sensing) (VVIR) in patients with complete heart block. DESIGN Double blind crossover comparison with one month in each pacing mode. PATIENTS 10 consecutive patients aged 23-74 presenting with complete anterograde atrioventricular block at rest and on exercise and with an intact atrial rate response received Synergyst I (Medtronic) pacemakers. MAIN OUTCOME MEASURES Symptom scores, maximal exercise performance on a treadmill, and the plasma concentrations of atrial natriuretic peptide, adrenaline, and noradrenaline. RESULTS No significant differences were identified between pacing modes in symptom scores for dyspnoea, fatigue, and mood disturbance; exercise time; and maximal oxygen consumption. One patient with intact ventriculoatrial conduction developed pacemaker syndrome during VVIR pacing. Resting plasma concentrations of atrial natriuretic peptide were raised in complete heart block and were restored to normal by DDD pacing but not by VVIR pacing. Resting plasma catecholamine concentrations were normal in complete heart block and in both pacing modes. During exercise the increase in the concentrations of all three hormones was similar in both pacing modes. CONCLUSIONS In patients with complete anterograde and retrograde atrioventricular block, symptoms and maximal exercise performance were no better during DDD than during VVIR pacing.
Collapse
Affiliation(s)
- K G Oldroyd
- Department of Medical Cardiology, Royal Infirmary, Glasgow
| | | | | | | | | |
Collapse
|
65
|
Affiliation(s)
- M W Baig
- Department of Medical Cardiology, General Infirmary Leeds, West Yorks, England
| | | |
Collapse
|
66
|
Rosenqvist M, Isaaz K, Botvinick EH, Dae MW, Cockrell J, Abbott JA, Schiller NB, Griffin JC. Relative importance of activation sequence compared to atrioventricular synchrony in left ventricular function. Am J Cardiol 1991; 67:148-56. [PMID: 1987716 DOI: 10.1016/0002-9149(91)90437-p] [Citation(s) in RCA: 214] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
This study evaluated the relative hemodynamic importance of a normal left ventricular (LV) activation sequence compared to atrioventricular (AV) synchrony with respect to systolic and diastolic function. Twelve patients with intact AV conduction and AV sequential pacemakers underwent radionuclide studies at rest and Doppler echocardiographic studies at rest and during submaximal exercise, comparing atrial demand pacing (AAI) to sequential AV sensing pacing (DDD) and ventricular demand pacing (VVI). Studies at rest were performed at a constant heart rate between pacing modes, and the exercise study was performed at a constant heart rate and work load. Cardiac output was higher during AAI than during both DDD and VVI (6.2 +/- 1 vs 5.6 +/- 1 and 5.3 +/- 1 liters/min, p less than 0.05). LV ejection fraction was likewise higher during AAI (55 +/- 12 vs 49 +/- 11 vs 51 +/- 13, p less than 0.05). VVI with or without AV synchrony was associated with a paradoxical septal motion pattern, resulting in a 25% impairment of regional septal ejection fraction. In addition, LV contraction duration was more homogenous during AAI. Peak filling rate during AAI and VVI was higher than during DDD (2.86 +/- 1 and 2.95 +/- 1 vs 2.25 +/- 1 end-diastolic volume/s; p less than 0.05). During VVI, the time to peak filling was significantly shorter than during both AAI and DDD (165 +/- 34 vs 239 +/- 99 and 224 +/- 99 ms; p less than 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- M Rosenqvist
- Department of Medicine, University of California, San Francisco
| | | | | | | | | | | | | | | |
Collapse
|
67
|
Janosik AL, Pearson AC, Labovitz AJ. Applications of Doppler echocardiography in cardiac pacing. Echocardiography 1991; 8:45-63. [PMID: 10149244 DOI: 10.1111/j.1540-8175.1991.tb01403.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
The purpose of this article is to review the use of Doppler echocardiography for assessing responses during cardiac pacing. Doppler techniques allow the physician to select the optimal mode pacemaker and pacemaker settings with regard to heart rate and atrioventricular delay, at rest and during exercise. Doppler parameters can be used to predict the relative hemodynamic advantage of dual chamber or rate adaptive pacing over fixed rate pacing. This valuable noninvasive modality may enhance the benefit of pacemaker therapy.
Collapse
Affiliation(s)
- A L Janosik
- Division of Cardiology, St. Louis University Hospital, MO 63110
| | | | | |
Collapse
|
68
|
Lau CP, Wong CK, Leung WH, Liu WX. Superior cardiac hemodynamics of atrioventricular synchrony over rate responsive pacing at submaximal exercise: observations in activity sensing DDDR pacemakers. Pacing Clin Electrophysiol 1990; 13:1832-7. [PMID: 1704550 DOI: 10.1111/j.1540-8159.1990.tb06899.x] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
The relative hemodynamic profile between dual chamber pacing (DDD) and activity sensing rate responsive pacing (VVIR) was compared in ten patients with dual chamber rate responsive pacemakers (Synergist II). With a double blind, randomized exercise protocol, DDDR pacemakers were programmed into VVI, VVIR, and DDD (AV interval 150 msec) modes and in seven patients the test in the DDD mode was repeated with the AV interval programmed at 75 msec. A treadmill exercise test of 6-minutes duration (2 stages, Stage I at 2 mph, 0% gradient and Stage II at 2 mph, 15% gradient) was performed at each of the programmed settings, with a rest period of 30 minutes in between tests. Cardiac output was assessed using continuous-wave Doppler sampling ascending aortic flow and expressed as a percentage of the value achieved during VVI pacing. During exercise, pacing rate between DDD and VVIR pacing was similar but was higher with DDD at the first minute of recovery (91 +/- 4 vs 81 +/- 3 beats/min, respectively). Cardiac output was significantly higher at rest, during low level exercise, and recovery with DDD pacing compared with VVIR pacing (resting: 21 +/- 14 vs -2 +/- 7%; Stage I: 36 +/- 6 vs 16 +/- 7%; Stage II: 25 +/- 15 vs 10 +/- 8%; recovery: 26 +/- 12 vs 4 +/- 9%; P less than 0.05 in all cases). Systolic blood pressure was significantly higher during low level of exercise in the DDD mode. Shortening of the AV interval to 75 msec did not significantly affect cardiac output during exercise, but cardiac output after exercise was reduced (2 +/- 6 vs 23 +/- 6% at an AV interval of 150 msec, P less than 0.02).(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- C P Lau
- Department of Medicine, Queen Mary Hospital, University of Hong Kong
| | | | | | | |
Collapse
|
69
|
Jutzy RV, Florio J, Isaeff DM, Marsa RJ, Bansal RC, Jutzy KR, Levine PA, Feenstra L. Comparative evaluation of rate modulated dual chamber and VVIR pacing. Pacing Clin Electrophysiol 1990; 13:1838-46. [PMID: 1704551 DOI: 10.1111/j.1540-8159.1990.tb06900.x] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
While dual chamber pacing is considered superior to VVI pacing at rest, there is a continuing debate as to the relative benefit of AV synchrony versus rate increase with exercise. To evaluate this question and to correlate different methods of evaluation, 14 patients with DDDR pacemakers were studied using serial treadmill exercise test with a CAEP protocol. Patients were exercised in DDD, DDDR, and VVIR modes. Echo-Doppler cardiac outputs were determined and pulmonary gas exchange was measured during exercise. There was a significant improvement in cardiac output with exercise in the DDDR versus VVIR modes, and in DDDR versus DDD modes in patients with chronotropic incompetence. There were small increases in exercise duration in DDDR versus VVIR modes, and small but consistent increases in VO2 at all levels of exercise, though not statistically significant. In this group of patients, DDDR pacing was superior to VVIR pacing, and superior to DDD pacing when chronotropic incompetence was present.
Collapse
Affiliation(s)
- R V Jutzy
- Section of Cardiology, Loma Linda University Medical Center, CA 92354
| | | | | | | | | | | | | | | |
Collapse
|
70
|
Hochleitner M, Hörtnagl H, Ng CK, Hörtnagl H, Gschnitzer F, Zechmann W. Usefulness of physiologic dual-chamber pacing in drug-resistant idiopathic dilated cardiomyopathy. Am J Cardiol 1990; 66:198-202. [PMID: 2371951 DOI: 10.1016/0002-9149(90)90588-r] [Citation(s) in RCA: 193] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
The beneficial effects of physiologic dual-chamber (DDD) pacing in the treatment of end-stage idiopathic dilated cardiomyopathy were evaluated in 16 patients in whom conventional drug therapy had failed. Candidates for cardiac transplantation as well as patients not accepted for transplantation participated. During DDD pacing at an atrioventricular delay of 100 ms, left ventricular ejection fraction increased from 16.0 +/- 8.4 to 25.6 +/- 8.6% (p less than 0.001) accompanied by a striking improvement in clinical symptoms, such as severe dyspnea at rest and pulmonary edema. The New York Heart Association class decreased from 3.6 +/- 0.4 to 2.1 +/- 0.5 (p less than 0.001). The decrease in cardiothoracic ratio from 0.60 +/- 0.06 to 0.56 +/- 0.05 (p less than 0.001) coincided with a decrease in left atrial and right ventricular echocardiographic dimensions, indicating a decrease in preload. Systolic blood pressure increased from 108 +/- 29 to 126 +/- 21 mm Hg (p less than 0.01) and diastolic blood pressure from 67 +/- 15 to 80 +/- 11 mm Hg (p less than 0.01). Normalization of heart rate was achieved. No major complications developed as a consequence of DDD pacing. All patients could be discharged from the hospital within 3 weeks after pacemaker implantation and return to a relatively normal life. Within 1 year after onset of DDD pacing only 4 of the patients died (from either sudden death or stroke). DDD pacing could represent an alternative approach to the management of chronic heart failure due to dilated cardiomyopathy, especially for heart transplant candidates and patients who are not accepted for cardiac transplantation, but no longer respond to drug therapy.
Collapse
Affiliation(s)
- M Hochleitner
- Department of Medicine, University of Innsbruck, Austria
| | | | | | | | | | | |
Collapse
|
71
|
Affiliation(s)
- R Sutton
- Westminster Hospital, London, United Kingdom
| |
Collapse
|