51
|
Fischer K, McDannold NJ, Zhang Y, Kardos M, Szabo A, Szabo A, Reusz GS, Jolesz FA. Renal ultrafiltration changes induced by focused US. Radiology 2009; 253:697-705. [PMID: 19703861 DOI: 10.1148/radiol.2532082100] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
PURPOSE To determine if focused ultrasonography (US) combined with a diagnostic microbubble-based US contrast agent can be used to modulate glomerular ultrafiltration and size selectivity. MATERIALS AND METHODS The experiments were approved by the animal care committee. The left kidney of 17 healthy rabbits was sonicated by using a 260-kHz focused US transducer in the presence of a microbubble-based US contrast agent. The right kidney served as the control. Three acoustic power levels were applied: 0.4 W (six rabbits), 0.9 W (six rabbits), and 1.7 W (five rabbits). Three rabbits were not treated with focused US and served as control animals. The authors evaluated changes in glomerular size selectivity by measuring the clearance rates of 3000- and 70,000-Da fluorescence-neutral dextrans. The creatinine clearance was calculated for estimation of the glomerular filtration rate. The urinary protein-creatinine ratio was monitored during the experiments. The authors assessed tubular function by evaluating the fractional sodium excretion, tubular reabsorption of phosphate, and gamma-glutamyltransferase-creatinine ratio. Whole-kidney histologic analysis was performed. For each measurement, the values obtained before and after sonication were compared by using the paired t test. RESULTS Significant (P < .05) increases in the relative (ratio of treated kidney value/nontreated kidney value) clearance of small- and large-molecule agents and the urine flow rates that resulted from the focused US treatments were observed. Overall, 1.23-, 1.23-, 1.61-, and 1.47-fold enhancement of creatinine clearance, 3000-Da dextran clearance, 70 000-Da dextran clearance, and urine flow rate, respectively, were observed. Focal tubular hemorrhage and transient functional tubular alterations were observed at only the highest (1.7-W) acoustic power level tested. CONCLUSION Glomerular ultrafiltration and size selectivity can be temporarily modified with simultaneous application of US and microbubbles. This method could offer new opportunities for treatment of renal disease.
Collapse
Affiliation(s)
- Krisztina Fischer
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Focused Ultrasound Laboratory, 221 Longwood Ave, Room 515, Boston, MA 02215, USA.
| | | | | | | | | | | | | | | |
Collapse
|
52
|
Hundt W, Yuh EL, Steinbach S, Bednarski MD, Guccione S. Mechanic effect of pulsed focused ultrasound in tumor and muscle tissue evaluated by MRI, histology, and microarray analysis. Eur J Radiol 2009; 76:279-87. [PMID: 19545959 DOI: 10.1016/j.ejrad.2009.05.044] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2008] [Revised: 04/06/2009] [Accepted: 05/25/2009] [Indexed: 12/20/2022]
Abstract
The purpose of this study was to investigate the effect of pulsed high-intensity focused ultrasound (HIFU) to tumor and muscle tissue. Pulsed HIFU was applied to tumor and muscle tissue in C3H/Km mice. Three hours after HIFU treatment pre- and post-contrast T1-wt, T2-wt images and a diffusion-wt STEAM-sequence were obtained. After MR imaging, the animals were euthenized and the treated tumor and muscle was taken out for histology and functional genomic analysis. In the tumor tissue a slight increase of the diffusion coefficient could be found. In the muscle tissue T2 images showed increased signal intensity and post-contrast T1 showed a decreased contrast uptake in the center and a severe contrast uptake in the surrounding muscle tissue. A significant increase of the diffusion coefficient was found. Gene expression analysis revealed profound changes in the expression levels of 29 genes being up-regulated and 3 genes being down-regulated in the muscle tissue and 31 genes being up-regulated and 15 genes being down-regulated in the SCCVII tumor tissue. Seven genes were up-regulated in both tissue types. The highest up-regulated gene in the tumor and muscle tissue encoded for Mouse histone H2A.1 gene (FC=13.2±20.6) and Apolipoprotein E (FC=12.8±27.4) respectively MHC class III (FC=83.7±67.4) and hsp70 (FC=75.3±85.0). Immunoblot confirmed the presence of HSP70 protein in the muscle tissue. Pulsed HIFU treatment on tumor and muscle tissue results in dramatic changes in gene expression, indicating that the effect of pulsed HIFU is in some regard dependent and also independent of the tissue type.
Collapse
Affiliation(s)
- Walter Hundt
- Lucas MRS Research Center, Department of Radiology, Stanford University School of Medicine, Stanford, CA 94305-5488, USA.
| | | | | | | | | |
Collapse
|
53
|
Hancock H, Dreher MR, Crawford N, Pollock CB, Shih J, Wood BJ, Hunter K, Frenkel V. Evaluation of pulsed high intensity focused ultrasound exposures on metastasis in a murine model. Clin Exp Metastasis 2009; 26:729-38. [PMID: 19517258 DOI: 10.1007/s10585-009-9272-9] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2009] [Accepted: 05/18/2009] [Indexed: 12/26/2022]
Abstract
High intensity focused ultrasound (HIFU) may be employed in two ways: continuous exposures for thermal ablation of tissue (> 60 degrees C), and pulsed-exposures for non-ablative effects, including low temperature hyperthermia (37-45 degrees C), and non thermal effects (e.g. acoustic cavitation and radiation forces). Pulsed-HIFU effects may enhance the tissue's permeability for improved delivery of drugs and genes, for example, by opening up gaps between cells in the vasculature and parenchyma. Inducing these effects may improve local targeting of therapeutic agents, however; concerns exist that pulsed exposures could theoretically also facilitate dissemination of tumor cells and exacerbate metastases. In the present study, the influence of pulsed-HIFU exposures on increasing metastatic burden was evaluated in a murine model with metastatic breast cancer. A preliminary study was carried out to validate the model and determine optimal timing for treatment and growth of lung metastases. Next, the effect of pulsed-HIFU on the metastatic burden was evaluated using quantitative image processing of whole-lung histological sections. Compared to untreated controls (2/15), a greater number of mice treated with pulsed-HIFU were found to have lungs "overgrown" with metastases (7/15), where individual metastases grew together such that they could not accurately be counted. Furthermore, area fraction of lung metastases (area of metastases/area of lungs) was approximately 30% greater in mice treated with pulsed-HIFU; however, these differences were not statistically significant. The present study details the development of an animal model for investigating the influence of interventional techniques or exposures (such as pulsed HIFU) on metastatic burden.
Collapse
Affiliation(s)
- Hilary Hancock
- Department of Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, MD 20892, USA
| | | | | | | | | | | | | | | |
Collapse
|
54
|
O’Neill BE, Vo H, Angstadt M, Li KPC, Quinn T, Frenkel V. Pulsed high intensity focused ultrasound mediated nanoparticle delivery: mechanisms and efficacy in murine muscle. ULTRASOUND IN MEDICINE & BIOLOGY 2009; 35:416-24. [PMID: 19081668 PMCID: PMC2668521 DOI: 10.1016/j.ultrasmedbio.2008.09.021] [Citation(s) in RCA: 63] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2008] [Revised: 08/05/2008] [Accepted: 09/19/2008] [Indexed: 05/09/2023]
Abstract
High intensity focused ultrasound (HIFU) is generally thought to interact with biological tissues in two ways: hyperthermia (heat) and acoustic cavitation. Pulsed mode HIFU has recently been demonstrated to increase the efficacy of a variety of drug therapies. Generally, it is presumed that the treatment acts to temporarily increase the permeability of the tissue to the therapeutic agent, however, the precise mechanism remains in dispute. In this article, we present evidence precluding hyperthermia as a principal mechanism for enhancing delivery, using a quantitative analysis of systemically administered fluorescent nanoparticles delivered to muscle in the calves of mice. Comparisons were carried out on the degree of enhancement between an equivalent heat treatment, delivered without ultrasound, and that of the pulsed-HIFU itself. In the murine calf muscle, Pulsed-HIFU treatment resulted in a significant increase in distribution of 200 nm particles (p < 0.016, n = 6), while the equivalent thermal dose showed no significant increase. Additional studies using this tissue/agent model also demonstrated that the pulsed HIFU enhancing effects persist for more than 24 h, which is longer than that of hyperthermia and acoustic cavitation, and offers the possibility of a novel third mechanism for mediating delivery.
Collapse
Affiliation(s)
- Brian E. O’Neill
- Diagnostic Radiology Department, Clinical Center, National Institute of Health, Bethesda, MD, USA
- Materials Reliability Division, National Institute of Standards and Technology, Boulder, CO, USA
| | - Howard Vo
- Diagnostic Radiology Department, Clinical Center, National Institute of Health, Bethesda, MD, USA
| | - Mary Angstadt
- Diagnostic Radiology Department, Clinical Center, National Institute of Health, Bethesda, MD, USA
| | - King P. C. Li
- Diagnostic Radiology Department, Clinical Center, National Institute of Health, Bethesda, MD, USA
| | - Tim Quinn
- Materials Reliability Division, National Institute of Standards and Technology, Boulder, CO, USA
| | - Victor Frenkel
- Diagnostic Radiology Department, Clinical Center, National Institute of Health, Bethesda, MD, USA
| |
Collapse
|
55
|
Evaluation of pharmacokinetics of bioreducible gene delivery vectors by real-time PCR. Pharm Res 2009; 26:1581-9. [PMID: 19240986 DOI: 10.1007/s11095-009-9847-9] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2008] [Accepted: 02/04/2009] [Indexed: 12/18/2022]
Abstract
PURPOSE To investigate pharmacokinetics of reversibly stabilized DNA nanoparticles (rSDN) using a single-step lysis RT-PCR. METHODS rSDN were prepared by coating bioreducible polycation/DNA polyplexes with multivalent N-(2-hydroxypropyl)methacrylamide (HPMA) copolymers. Targeted polyplexes were formulated by linking cyclic RGD ligand (c(RGDyK)) to the HPMA surface layer of rSDN. The pharmacokinetic parameters in tumor-bearing mice were analyzed by PKAnalyst. RESULTS The pharmacokinetics of naked plasmid DNA, simple DNA polyplexes, rSDN, and RGD-targeted rSDN exhibited two-compartment model characteristics with area under the blood concentration-time curve (AUC) increasing from 1,102 ng x ml(-1) x min(-1) for DNA to 3,501 ng x ml(-1) x min(-1) for rSDN. Non-compartment model analysis revealed increase in mean retention time (MRT) from 4.5 min for naked DNA to 22.9 min for rSDN. CONCLUSIONS RT-PCR is a sensitive and convenient method suitable for analyzing pharmacokinetics and biodistribution of DNA polyplexes. Surface stabilization of DNA polyplexes can significantly extend their MRT and AUC compared to naked DNA. DNA degradation in rSDN in blood circulation, due to a combined effect of disulfide reduction and competitive reactions with charged molecules in the blood, contributes to DNA elimination.
Collapse
|
56
|
O'Neill BE, Li KCP. Augmentation of targeted delivery with pulsed high intensity focused ultrasound. Int J Hyperthermia 2009; 24:506-20. [PMID: 18608574 DOI: 10.1080/02656730802093661] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022] Open
Abstract
This paper reviews the enhanced delivery of genes, drugs and therapeutics using ultrasound. It begins with a general overview of the field and the various techniques associated with it, including sonophoresis, hyperthermia (with ultrasound), sonoporation, and microbubble assisted transvascular and targeted delivery. Particular attention is then paid to pulsed high intensity focused ultrasound drug delivery without the use of ultrasound contrast agents. Feasibility and mechanistic studies of this technique are described in some detail. Conclusions are then drawn regarding possible mechanisms of this treatment, and to contrast with the better known treatments relying on injection of ultrasound contrast agents.
Collapse
Affiliation(s)
- Brian E O'Neill
- Department of Radiology, The Methodist Hospital, Houston, TX 77030, USA
| | | |
Collapse
|
57
|
Patel PR, Luk A, Durrani A, Dromi S, Cuesta J, Angstadt M, Dreher MR, Wood BJ, Frenkel V. In vitro and in vivo evaluations of increased effective beam width for heat deposition using a split focus high intensity ultrasound (HIFU) transducer. Int J Hyperthermia 2009; 24:537-49. [PMID: 18608578 DOI: 10.1080/02656730802064621] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022] Open
Abstract
PURPOSE To develop a novel and efficient, in vitro method for characterizing temporal and spatial heat generation of focused ultrasound exposures, and evaluate this method to compare a split focus and conventional single focus high intensity focused ultrasound transducer. MATERIALS AND METHODS A HIFU tissue-mimicking phantom was validated by comparing respective temperature elevations generated in the phantoms and in murine tumors in vivo. The phantom was then used in combination with IR thermography to spatially and temporally characterize differences in low-level temperature elevation (e.g. 3-5 degrees C) produced by a single focus and split focus HIFU transducer, where the latter produces four simultaneous foci. In vivo experiments with heat sensitive liposomes containing doxorubicin were then carried out to determine if the larger beam width of the split focus transducer, compared to the single focus, could increase overall deployment of the drug from the liposome. RESULTS Temperature elevations generated in the HIFU phantom were not found to be different from those measured in vivo when compensating for disparities in attenuation coefficient and specific heat, and between the two transducers by increasing the energy deposition. Exposures with the split focus transducer provided significant increases in the area treated compared to the single focus, which then translated to significant increases in drug deposition in vivo. CONCLUSIONS Preliminary evidence was provided indicating the potential for using this novel technique for characterizing hyperthermia produced by focused ultrasound devices. Further development will be required for its suitability for correlating in vitro and in vivo outcomes.
Collapse
Affiliation(s)
- Pretesh R Patel
- Diagnostic Radiology Department, Clinical Center, National Institutes of Health, Bethesda, MD 20892, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
58
|
Frenkel V. Ultrasound mediated delivery of drugs and genes to solid tumors. Adv Drug Deliv Rev 2008; 60:1193-208. [PMID: 18474406 DOI: 10.1016/j.addr.2008.03.007] [Citation(s) in RCA: 336] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2008] [Accepted: 03/04/2008] [Indexed: 12/21/2022]
Abstract
It has long been shown that therapeutic ultrasound can be used effectively to ablate solid tumors, and a variety of cancers are presently being treated in the clinic using these types of ultrasound exposures. There is, however, an ever-increasing body of preclinical literature that demonstrates how ultrasound energy can also be used non-destructively for increasing the efficacy of drugs and genes for improving cancer treatment. In this review, a summary of the most important ultrasound mechanisms will be given with a detailed description of how each one can be employed for a variety of applications. This includes the manner by which acoustic energy deposition can be used to create changes in tissue permeability for enhancing the delivery of conventional agents, as well as for deploying and activating drugs and genes via specially tailored vehicles and formulations.
Collapse
|
59
|
Poff JA, Allen CT, Traughber B, Colunga A, Xie J, Chen Z, Wood BJ, Van Waes C, Li KCP, Frenkel V. Pulsed high-intensity focused ultrasound enhances apoptosis and growth inhibition of squamous cell carcinoma xenografts with proteasome inhibitor bortezomib. Radiology 2008; 248:485-91. [PMID: 18574138 DOI: 10.1148/radiol.2482071674] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
PURPOSE To investigate whether combining pulsed high-intensity focused ultrasound (HIFU) with the chemotherapeutic drug bortezomib could improve antitumor activity against murine squamous cell carcinoma (SCC) tumors. MATERIALS AND METHODS All experiments were conducted with animal care and use committee approval. Murine SCC cells were implanted subcutaneously in C3H mice. When tumors reached 100 mm(3), mice were randomized to one of three groups for twice weekly intraperitoneal injections of 1.5 mg of bortezomib per kilogram of body weight, a proteasome inhibitor (n = 10); 1.0 mg/kg bortezomib (n = 11); or a control vehicle (n = 12). Within each group, half of the mice received pulsed HIFU exposure to their tumors immediately prior to each injection. The time for tumors to reach 650 mm(3) was compared among groups. Additional tumors were stained with terminal deoxynucledotidyl transferase-mediated dUTP nick end labeling and CD31 to assess apoptotic index and blood vessel density, respectively. RESULTS Tumors in the control group, pulsed HIFU and control group, and 1.0 mg/kg of bortezomib alone group reached the size end point in 5.2 days +/- 0.8 (standard deviation), 5.3 days +/- 0.8, and 5.6 days +/- 1.1, respectively. However, pulsed HIFU and 1.0 mg/kg bortezomib increased the time to end point to 9.8 days +/- 2.9 (P < .02), not significantly different from the 8.8 days +/- 2.1 in tumors treated with 1.5 mg/kg bortezomib alone (P > .05). Combination therapy was also associated with a significantly higher apoptotic index (P < .05). CONCLUSION Treatment of tumors with pulsed HIFU lowered the threshold level for efficacy of bortezomib, resulting in significant tumor cytotoxicity and growth inhibition at lower dose levels.
Collapse
Affiliation(s)
- Jason A Poff
- Diagnostic Radiology Department, Clinical Center and Head and Neck Surgery Branch, National Institutes of Health, 9000 Rockville Pike, Bethesda, MD 20892, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
60
|
Shen ZP, Brayman AA, Chen L, Miao CH. Ultrasound with microbubbles enhances gene expression of plasmid DNA in the liver via intraportal delivery. Gene Ther 2008; 15:1147-55. [PMID: 18385766 DOI: 10.1038/gt.2008.51] [Citation(s) in RCA: 67] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Current ultrasound (US)-mediated gene delivery methods are inefficient due, in part, to a lack of US optimization. We systematically explored the use of microbubbles (MBs), US parameters and plasmid delivery routes to improve gene transfer into the mouse liver. Co-presentation of plasmid DNA (pDNA), 10% Optison MBs and pulsed 1-MHz US at a peak negative pressure of 4.3 MPa significantly increased luciferase gene expression with pDNA delivered by intrahepatic injection to the left liver lobe. Intraportal injection delivered pDNA and MBs to the whole liver; with insonation, all lobes expressed the transgene, thus increasing total gene expression. Gene expression was also dependent on acoustic pressure over the range of 0-4.3 MPa, with a peak effect at 3 MPa. An average of 85-fold enhancement in gene delivery was achieved. No enhancement was observed below 0.25 MPa. Increasing pulse length while decreasing pulse repetition frequency and exposure time to maintain a constant total energy during exposure did not further improve transfection efficiency, nor did extend the US exposure pre- or postinjection of pDNA. The results indicate that coupled with MBs, US can more efficiently and dose-dependently enhance gene expression from pDNA delivered via portal vein injection by an acoustic mechanism of inertial cavitation.
Collapse
Affiliation(s)
- Z P Shen
- Seattle Children's Hospital Research Institute, Seattle, WA, USA
| | | | | | | |
Collapse
|
61
|
Schmitz AC, Gianfelice D, Daniel BL, Mali WPTM, van den Bosch MAAJ. Image-guided focused ultrasound ablation of breast cancer: current status, challenges, and future directions. Eur Radiol 2008; 18:1431-41. [PMID: 18351348 PMCID: PMC2441491 DOI: 10.1007/s00330-008-0906-0] [Citation(s) in RCA: 89] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2007] [Revised: 12/04/2007] [Accepted: 01/15/2008] [Indexed: 01/06/2023]
Abstract
Image-guided focussed ultrasound (FUS) ablation is a non-invasive procedure that has been used for treatment of benign or malignant breast tumours. Image-guidance during ablation is achieved either by using real-time ultrasound (US) or magnetic resonance imaging (MRI). The past decade phase I studies have proven MRI-guided and US-guided FUS ablation of breast cancer to be technically feasible and safe. We provide an overview of studies assessing the efficacy of FUS for breast tumour ablation as measured by percentages of complete tumour necrosis. Successful ablation ranged from 20% to 100%, depending on FUS system type, imaging technique, ablation protocol, and patient selection. Specific issues related to FUS ablation of breast cancer, such as increased treatment time for larger tumours, size of ablation margins, methods used for margin assessment and residual tumour detection after FUS ablation, and impact of FUS ablation on sentinel node procedure are presented. Finally, potential future applications of FUS for breast cancer treatment such as FUS-induced anti-tumour immune response, FUS-mediated gene transfer, and enhanced drug delivery are discussed. Currently, breast-conserving surgery remains the gold standard for breast cancer treatment.
Collapse
Affiliation(s)
- A C Schmitz
- Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
| | | | | | | | | |
Collapse
|
62
|
Hundt W, Yuh EL, Steinbach S, Bednarski MD, Guccione S. Comparison of continuous vs. pulsed focused ultrasound in treated muscle tissue as evaluated by magnetic resonance imaging, histological analysis, and microarray analysis. Eur Radiol 2008; 18:993-1004. [PMID: 18205005 DOI: 10.1007/s00330-007-0848-y] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2007] [Revised: 10/30/2007] [Accepted: 12/21/2007] [Indexed: 12/12/2022]
Abstract
The purpose of this study was to investigate the effect of different application modes of high intensity focused ultrasound (HIFU) to muscle tissue. HIFU was applied to muscle tissue of the flank in C3H/Km mice. Two dose regimes were investigated, a continuous HIFU and a short-pulsed HIFU mode. Three hours after HIFU treatment pre- and post-contrast T1-weighted, T2-weighted images and a diffusion-weighted STEAM sequence were obtained. After MR imaging, the animals were euthanized and the treated, and the non-treated tissue was taken out for histology and functional genomic analysis. T2 images showed increased signal intensity and post-contrast T1 showed a decreased contrast uptake in the central parts throughout the tissue of both HIFU modes. A significantly higher diffusion coefficient was found in the muscle tissue treated with continuous wave focused ultrasound. Gene expression analysis revealed profound changes of 54 genes. For most of the analyzed genes higher expression was found after treatment with the short-pulse mode. The highest up-regulated genes encoded for the MHC class III (FC approximately 84), HSP 70 (FC approximately 75) and FBJ osteosarcoma related oncogene (FC approximately 21). Immunohistology and the immunoblot analysis confirmed the presence of HSP70 protein in both applied HIFU modes. The use of HIFU treatment on muscle tissue results in dramatic changes in gene expression; however, the same genes are up-regulated after the application of continuous or pulsed HIFU, indicating that the tissue reaction is independent of the type of tissue damage.
Collapse
Affiliation(s)
- Walter Hundt
- Lucas MRS Research Center, Department of Radiology, Stanford University School of Medicine, Stanford, CA 94305-5488, USA.
| | | | | | | | | |
Collapse
|
63
|
Khaibullina A, Jang BS, Sun H, Le N, Yu S, Frenkel V, Carrasquillo JA, Pastan I, Li KCP, Paik CH. Pulsed high-intensity focused ultrasound enhances uptake of radiolabeled monoclonal antibody to human epidermoid tumor in nude mice. J Nucl Med 2008; 49:295-302. [PMID: 18199622 DOI: 10.2967/jnumed.107.046888] [Citation(s) in RCA: 65] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
UNLABELLED The aim of this study was to determine if pulsed high-intensity focused ultrasound (HIFU) exposures could enhance tumor uptake of (111)In-MX-B3, a murine IgG1kappa monoclonal antibody directed against the Le(y) antigen. METHODS MX-B3 was labeled with (111)In, purified, and confirmed for its binding to the antigen-positive A431 cell line. Groups of nude mice were inoculated subcutaneously with A431 tumor cells on both hind flanks. A tumor on one flank was treated with pulsed-HIFU; the other tumor was used as an untreated control. Within 10 min after the HIFU exposure, the mice received intravenous (111)In-MX-B3 for imaging and biodistribution studies. Mice were euthanized at 1, 24, 48, and 120 h after injection for biodistribution studies. RESULTS The HIFU exposure shortened the peak tumor uptake time (24 vs. 48 h for the control) and increased the peak tumor uptake value (38 vs. 25 %ID/g [percentage injected dose per gram] for the control). The HIFU effect on enhancing tumor uptake was greater at earlier times up to 24 h, but the effect was gradually diminished thereafter. The HIFU effect on enhancing tumor uptake was substantiated by nuclear imaging studies. HIFU also increased the uptake of the antibody in surrounding tissues, but the net increase was marginal compared with the increase in tumor uptake. CONCLUSION This study demonstrates that pulsed-HIFU significantly enhances the delivery of (111)In-MX-B3 in human epidermoid tumors xenografted in nude mice. The results of this pilot study warrant further evaluation of other treatment regimens, such as repeated HIFU exposures for greater delivery enhancement of antibodies labeled with cytotoxic radioisotopes or pulsed-HIFU exposure in addition to a combined therapy of (90)Y-B3 and taxol to enhance the synergistic effect.
Collapse
Affiliation(s)
- Alfia Khaibullina
- Department of Radiology, Clinical Center, National Institutes of Health, Bethesda, Maryland 20892, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
64
|
Deckers R, Rome C, Moonen CT. The role of ultrasound and magnetic resonance in local drug delivery. J Magn Reson Imaging 2008; 27:400-9. [DOI: 10.1002/jmri.21272] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
|
65
|
Duvshani-Eshet M, Benny O, Morgenstern A, Machluf M. Therapeutic ultrasound facilitates antiangiogenic gene delivery and inhibits prostate tumor growth. Mol Cancer Ther 2007; 6:2371-82. [PMID: 17699732 DOI: 10.1158/1535-7163.mct-07-0019] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Gene therapy clinical trials are limited due to several hurdles concerning the type of vector used, particularly, the viral vectors, and transfection efficacy when non-viral vectors are used. Therapeutic ultrasound is a promising non-viral technology that can be used in the clinical setting. Here, for the first time, we show the efficacy of therapeutic ultrasound to deliver genes encoding for hemopexin-like domain fragment (PEX), an inhibitor of angiogenesis, to prostate tumors in vivo. Moreover, the addition of an ultrasound contrast agent (Optison) to the transfection process was evaluated. Prostate cancer cells and endothelial cells (EC) were transfected in vitro with cDNA-PEX using therapeutic ultrasound alone (TUS + pPEX) or with Optison (TUS + pPEX + Optison). The biological activity of the expressed PEX was assessed using proliferation, migration, and apoptosis assays done on EC and prostate cancer cells. TUS + pPEX + Optison led to the inhibition of EC and prostate cancer cell proliferation (<65%), migration (<50%), and an increase in apoptosis. In vivo, C57/black mice were inoculated s.c. with prostate cancer cells. The tumors were treated with TUS + pPEX and TUS + pPEX + Optison either once or repeatedly. Tumor growth was evaluated, after which histology and immunohistochemistry analyses were done. A single treatment of TUS + pPEX led to a 35% inhibition in tumor growth. Using TUS + PEX + Optison led to an inhibition of 50%. Repeated treatments of TUS + pPEX + Optison were found to significantly (P < 0.001) inhibit prostate tumor growth by 80%, along with the angiogenic indices, with no toxicity to the surrounding tissues. These results depict the efficacy of therapeutic ultrasound as a non-viral technology to efficiently deliver genes to tumors in general, and to deliver angiogenic inhibitors to prostate cancer in particular.
Collapse
Affiliation(s)
- Maayan Duvshani-Eshet
- The Faculty of Biotechnology and Food Engineering, Technion-Israel Institute of Technology, Haifa 32000, Israel
| | | | | | | |
Collapse
|
66
|
Dromi S, Frenkel V, Luk A, Traughber B, Angstadt M, Bur M, Poff J, Xie J, Libutti SK, Li KC, Wood BJ. Pulsed-high intensity focused ultrasound and low temperature-sensitive liposomes for enhanced targeted drug delivery and antitumor effect. Clin Cancer Res 2007; 13:2722-7. [PMID: 17473205 PMCID: PMC2555974 DOI: 10.1158/1078-0432.ccr-06-2443] [Citation(s) in RCA: 333] [Impact Index Per Article: 19.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
PURPOSE To determine if pulsed-high intensity focused ultrasound (HIFU) could effectively serve as a source of hyperthermia with thermosensitive liposomes to enhance delivery and efficacy of doxorubicin in tumors. EXPERIMENTAL DESIGN Comparisons in vitro and in vivo were carried out between non-thermosensitive liposomes (NTSL) and low temperature-sensitive liposomes (LTSL). Liposomes were incubated in vitro over a range of temperatures and durations, and the amount of doxorubicin released was measured. For in vivo experiments, liposomes and free doxorubicin were injected i.v. in mice followed by pulsed-HIFU exposures in s.c. murine adenocarcinoma tumors at 0 and 24 h after administration. Combinations of the exposures and drug formulations were evaluated for doxorubicin concentration and growth inhibition in the tumors. RESULTS In vitro incubations simulating the pulsed-HIFU thermal dose (42 degrees C for 2 min) triggered release of 50% of doxorubicin from the LTSLs; however, no detectable release from the NTSLs was observed. Similarly, in vivo experiments showed that pulsed-HIFU exposures combined with the LTSLs resulted in more rapid delivery of doxorubicin as well as significantly higher i.t. concentration when compared with LTSLs alone or NTSLs, with or without exposures. Combining the exposures with the LTSLs also significantly reduced tumor growth compared with all other groups. CONCLUSIONS Combining low-temperature heat-sensitive liposomes with noninvasive and nondestructive pulsed-HIFU exposures enhanced the delivery of doxorubicin and, consequently, its antitumor effects. This combination therapy could potentially produce viable clinical strategies for improved targeting and delivery of drugs for treatment of cancer and other diseases.
Collapse
Affiliation(s)
- Sergio Dromi
- Diagnostic Radiology Department, Clinical Center, National Cancer Institute, NIH, Bethesda, Maryland
| | - Victor Frenkel
- Diagnostic Radiology Department, Clinical Center, National Cancer Institute, NIH, Bethesda, Maryland
| | - Alfred Luk
- Diagnostic Radiology Department, Clinical Center, National Cancer Institute, NIH, Bethesda, Maryland
| | - Bryan Traughber
- Diagnostic Radiology Department, Clinical Center, National Cancer Institute, NIH, Bethesda, Maryland
| | - Mary Angstadt
- Diagnostic Radiology Department, Clinical Center, National Cancer Institute, NIH, Bethesda, Maryland
| | - Monica Bur
- Diagnostic Radiology Department, Clinical Center, National Cancer Institute, NIH, Bethesda, Maryland
| | - Jason Poff
- Diagnostic Radiology Department, Clinical Center, National Cancer Institute, NIH, Bethesda, Maryland
| | - Jianwu Xie
- Diagnostic Radiology Department, Clinical Center, National Cancer Institute, NIH, Bethesda, Maryland
| | - Steven K. Libutti
- Tumor Angiogenesis Section, Surgery Branch, National Cancer Institute, NIH, Bethesda, Maryland
| | - King C.P. Li
- Diagnostic Radiology Department, Clinical Center, National Cancer Institute, NIH, Bethesda, Maryland
| | - Bradford J. Wood
- Diagnostic Radiology Department, Clinical Center, National Cancer Institute, NIH, Bethesda, Maryland
| |
Collapse
|
67
|
Stone MJ, Frenkel V, Dromi S, Thomas P, Lewis RP, Li KCP, Horne M, Wood BJ. Pulsed-high intensity focused ultrasound enhanced tPA mediated thrombolysis in a novel in vivo clot model, a pilot study. Thromb Res 2007; 121:193-202. [PMID: 17481699 PMCID: PMC2169501 DOI: 10.1016/j.thromres.2007.03.023] [Citation(s) in RCA: 66] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2007] [Revised: 03/08/2007] [Accepted: 03/09/2007] [Indexed: 11/29/2022]
Abstract
INTRODUCTION Thrombotic disease continues to account for significant morbidity and mortality. Ultrasound energy has been investigated as a potential primary and adjunctive treatment for thrombotic disease. We have previously shown that pulsed-high intensity focused ultrasound (HIFU) enhances thrombolysis induced by tissue plasminogen activator (tPA) in vitro, including describing the non-destructive mechanism by which tPA availability and consequent activity are increased. In this study we aimed to determine if the same effects could be achieved in vivo. MATERIALS AND METHODS In this study, pulsed-HIFU exposures combined with tPA boluses were compared to treatment with tPA alone, HIFU alone and control in a novel in vivo clot model. Clots were formed in the rabbit marginal ear vein and verified using venography and infrared imaging. The efficacy of thrombolytic treatment was monitored via high resolution ultrasonography for 5 h post-treatment. The cross-sectional area of clots at 4 points along the vein was measured and normalized to the pre-treatment size. RESULTS At 5 h the complete recanalization of clots treated with pulsed-HIFU and tPA was significantly different from the partial recanalization seen with tPA treatment alone. tPA treatment alone showed a significant decrease in clot versus control, where HIFU was not significantly different than control. Histological analysis of the vessel walls in the treated veins showed no apparent irreversible damage to endothelial cells or extravascular tissue. CONCLUSIONS This study demonstrates that tPA mediated thrombolysis can be significantly enhanced when combined with non-invasive pulsed-HIFU exposures.
Collapse
Affiliation(s)
- Michael J. Stone
- Diagnostic Radiology Department, Clinical Center, National Institutes of Health, Bethesda, MD, USA
- Howard Hughes Medical Institute Research Scholars Program
| | - Victor Frenkel
- Diagnostic Radiology Department, Clinical Center, National Institutes of Health, Bethesda, MD, USA
| | - Sergio Dromi
- Diagnostic Radiology Department, Clinical Center, National Institutes of Health, Bethesda, MD, USA
| | - Peter Thomas
- Division of Bioengineering and Physical Science, Office of Research Services, National Institutes of Health, Bethesda, MD, USA
| | - Ryan P. Lewis
- Diagnostic Radiology Department, Clinical Center, National Institutes of Health, Bethesda, MD, USA
| | - King CP Li
- Diagnostic Radiology Department, Clinical Center, National Institutes of Health, Bethesda, MD, USA
| | - McDonald Horne
- Department of Laboratory Medicine, Clinical Center, National Institutes of Health, Bethesda, MD, USA
| | - Bradford J. Wood
- Diagnostic Radiology Department, Clinical Center, National Institutes of Health, Bethesda, MD, USA
| |
Collapse
|
68
|
Abstract
Ultrasound exposure (USE) in the presence of microbubbles (MCB) (e.g. contrast agents used to enhance ultrasound imaging) increases plasmid transfection efficiency in vitro by several orders of magnitude. Formation of short-lived pores in the plasma membrane ('sonoporation'), up to 100 nm in effective diameter lasting a few seconds, is implicated as the dominant mechanism, associated with acoustic cavitation. Ultrasound enhanced gene transfer (UEGT) has also been successfully achieved in vivo, with reports of spatially restricted and therapeutically relevant levels of transgene expression. Loading MCB with nucleic acids and/or disease-targeting ligands may further improve the efficiency and specificity of UEGT such that clinical testing becomes a realistic prospect.
Collapse
Affiliation(s)
- C M H Newman
- Cardiovascular Research Unit, School of Medicine and Biomedical Sciences, University of Sheffield, Sheffield, UK.
| | | |
Collapse
|
69
|
Frenkel V, Li KCP. Potential role of pulsed-high intensity focused ultrasound in gene therapy. Future Oncol 2006; 2:111-9. [PMID: 16556078 DOI: 10.2217/14796694.2.1.111] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
As the understanding of human cancer biology increases, new potential strategies for gene therapy are being proposed and evaluated. However, safe and efficient gene transfer continues to be the major hurdle for its implementation in the clinic. Preclinical studies have shown how pulsed-high intensity focused ultrasound (HIFU) exposures can be combined with different modes of administration (local, intravascular and systemic) to improve local delivery of genes and other therapeutic agents. Using image guidance, exposures are given, where short pulses of energy create predominantly mechanical/structural effects in the tissues as opposed to thermal ones. The result is an increase in both extravasation and interstitial diffusion of macromolecules, which occur non-destructively and reversibly. Ultrasound contrast agents can also be added, which enhance acoustic cavitation activity and consequently sonoporation. By being able to locally increase the uptake and expression of DNA, pulsed-HIFU holds much promise to further the use and applications of gene therapy for treating cancer and other pathological conditions.
Collapse
Affiliation(s)
- Victor Frenkel
- Diagnostic Radiology Department, Clinial Center, National Institutes of Health, Bethesda, MD, USA.
| | | |
Collapse
|
70
|
Klibanov AL. Microbubble contrast agents: targeted ultrasound imaging and ultrasound-assisted drug-delivery applications. Invest Radiol 2006; 41:354-62. [PMID: 16481920 DOI: 10.1097/01.rli.0000199292.88189.0f] [Citation(s) in RCA: 278] [Impact Index Per Article: 15.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
The use of microbubble contrast agents for general tissue delineation and perfusion enjoys steady interest in ultrasound imaging. Microbubbles as contrast materials require a small dosage and show excellent detection sensitivity. Targeting ligands on the surface of microbubbles permit the selective accumulation of these particles in the areas of interest, which show an up-regulated level of receptor molecules on vascular endothelium. Selective contrast imaging of inflammation, ischemia-reperfusion injury, angiogenesis, and thrombosis has been achieved in animal models. Ultrasound-assisted drug delivery and activation, performed by combining microbubble agent containing drug substances or coadministered with pharmaceutical agents (including plasmid DNA for transfection), has been achieved in multiple model systems in vitro and in vivo. Ultrasound and microbubbles-based targeted acceleration of the thrombolytic enzyme action already have reached clinical trials. Overall, microbubble targeting and ultrasound-assisted microbubble-based drug-delivery systems will offer a step toward the application of targeted personalized diagnostics and therapy.
Collapse
Affiliation(s)
- Alexander L Klibanov
- Department of Internal Medicine, Cardiovascular Division, University of Virginia, Charlottesville, Virginia 22908-0158, USA.
| |
Collapse
|
71
|
Frenkel V, Etherington A, Greene M, Quijano J, Xie J, Hunter F, Dromi S, Li KCP. Delivery of liposomal doxorubicin (Doxil) in a breast cancer tumor model: investigation of potential enhancement by pulsed-high intensity focused ultrasound exposure. Acad Radiol 2006; 13:469-79. [PMID: 16554227 DOI: 10.1016/j.acra.2005.08.024] [Citation(s) in RCA: 114] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2005] [Revised: 08/20/2005] [Accepted: 08/20/2005] [Indexed: 10/24/2022]
Abstract
RATIONALE AND OBJECTIVES To investigate the potential of using pulsed high-intensity focused ultrasound (HIFU) exposures to enhance the delivery, and hence therapeutic effect of liposomal doxorubicin (Doxil) in a murine breast cancer tumor model. MATERIALS AND METHODS Tumors were grown in the bilateral flanks of mice using a mammary adenocarcinoma cell line. Experiments consisted of exposing one of two tumors to pulsed-HIFU, followed by tail vein injections of Doxil. Tumor growth rates were monitored, and assays carried out for doxorubicin concentration in these tumors as well as in a second (squamous cell carcinoma) tumor model and in muscle. Laser scanning confocal microscopy was used with fluorescent probes to observe both the uptake of polystyrene nanoparticles and dilation of exposed blood vessels. Additional experiments involving histologic analysis and real-time temperature measurements were performed to determine the safety of the exposures. RESULTS Pulsed-HIFU exposures were shown to be safe, producing no apparent deleterious effects in the tumors. The exposures, however, were not found to enhance the delivery of Doxil, and consequently did not allow for lower doses for obtaining tumor regression. Imaging with a fluorescent dextran showed blood vessels to be dilated as a result of the exposures. Experiments with polystyrene nanoparticles of similar size to the liposomes showed a greater abundance to be present in the treated tumors. CONCLUSION Although past studies have shown the advantages of pulsed-HIFU exposures for enhancing delivery, this was not observed with the liposomes, apparently because of their inherent ability to preferentially accumulate into tumors on their own. Potential mechanisms for enhanced uptake of non-liposomal nanoparticles are discussed.
Collapse
Affiliation(s)
- Victor Frenkel
- Diagnostic Radiology Department, Clinical Center, National Institutes of Health, Building 10, Room 1N306a, 10 Center Drive, Bethesda, MD 20892, USA.
| | | | | | | | | | | | | | | |
Collapse
|
72
|
Frenkel V, Oberoi J, Stone MJ, Park M, Deng C, Wood BJ, Neeman Z, Horne M, Li KCP. Pulsed high-intensity focused ultrasound enhances thrombolysis in an in vitro model. Radiology 2006; 239:86-93. [PMID: 16493016 PMCID: PMC2386885 DOI: 10.1148/radiol.2391042181] [Citation(s) in RCA: 81] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To evaluate the use of pulsed high-intensity focused ultrasound exposures to improve tissue plasminogen activator (tPA)-mediated thrombolysis in an in vitro model. MATERIALS AND METHODS All experimental work was compliant with institutional guidelines and HIPAA. Clots were formed by placing 1 mL of human blood in closed-off sections of pediatric Penrose tubes. Four experimental groups were evaluated: control (nontreated) clots, clots treated with pulsed high-intensity focused ultrasound only, clots treated with tPA only, and clots treated with pulsed high-intensity focused ultrasound plus tPA. The focused ultrasound exposures (real or sham) were followed by incubations of the clots in tPA with saline or in saline only. Thrombolysis was measured as the relative reduction in the mass of the clot. D-Dimer assays also were performed. Two additional experiments were performed and yielded dose-response curves for two exposure parameters: number of pulses per raster point and total acoustic power. Radiation force-induced displacements caused by focused ultrasound exposures were simulated in the clots. A Tukey-Kramer honestly significant difference test was performed for comparisons between all pairs of experimental groups. RESULTS The clots treated with focused ultrasound alone did not show significant increases in thrombolysis compared with the control clots. The clots treated with focused ultrasound plus tPA showed a 50% ([30.2/20.1]/20.1) increase in the degree of thrombolysis compared with the clots treated with tPA only (P < .001), further corroborating the d-dimer assay results (P < .001). Additional experiments revealed how increasing both the number of pulses per raster point and the total acoustic power yielded corresponding increases in the thrombolysis rate. In the latter experiment, simulations performed at a range of power settings revealed a direct correlation between increased displacement and observed thrombolysis rate. CONCLUSION The rate of tPA-mediated thrombolysis can be enhanced by using pulsed high-intensity focused ultrasound exposure in vitro.
Collapse
Affiliation(s)
- Victor Frenkel
- Departments of Diagnostic Radiology and Laboratory Medicine, Clinical Center, National Institutes of Health, 10 Center Drive, Bldg 10, Room 1C657, Bethesda, MD 20892, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|