Oikarinen L, Toivonen L, Viitasalo M. Electrocardiographic measures of ventricular repolarisation dispersion in patients with coronary artery disease susceptible to ventricular fibrillation.
Heart 1998;
79:554-9. [PMID:
10078081 PMCID:
PMC1728728 DOI:
10.1136/hrt.79.6.554]
[Citation(s) in RCA: 11] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/03/2022] Open
Abstract
OBJECTIVE
To study electrocardiographic measures of ventricular repolarisation dispersion in patients prone to ventricular fibrillation compared with controls matched for the extent of coronary heart disease and the use of beta blockers.
DESIGN
A case-control study.
SETTING
Cardiovascular laboratory of a tertiary referral centre.
PATIENTS
Fifty patients with documented ventricular fibrillation not associated with acute myocardial infarction, and their controls matched for sex, age, number of diseased coronary vessels, left ventricular ejection fraction, previous myocardial infarction and its location, and the use of beta blockers.
MAIN OUTCOME MEASURES
Electrocardiographic measures of QT, JT, and Tend interval dispersions in a 12 lead electrocardiogram.
RESULTS
The ventricular fibrillation patients compared to controls showed increased mean (SD) QTapex dispersion (53 (18) ms v 44 (18) ms, respectively; p < 0.01) and mean (SD) Tend dispersion (46 (17) ms v 38 (15) ms, respectively; p < 0.05).
CONCLUSIONS
Increased QTapex and Tend dispersions are associated with a susceptibility to ventricular fibrillation even when the extent of the coronary heart disease and use of beta blockers are taken into consideration. However, because of a considerable overlap between the groups, measures of QT dispersion assessed from a 12 lead electrocardiogram do not provide clinically useful information for identification of patients at risk of sudden cardiac death.
Collapse