51
|
Analysis of thyroid hormones in serum by liquid chromatography-tandem mass spectrometry. Anal Bioanal Chem 2010; 397:1831-9. [PMID: 20437035 DOI: 10.1007/s00216-010-3705-9] [Citation(s) in RCA: 89] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2010] [Revised: 03/24/2010] [Accepted: 03/29/2010] [Indexed: 11/27/2022]
Abstract
Thyroid hormones are essential hormones for regulating growth and development in humans and wildlife. Methods to monitor precise and low levels of these hormones in serum and tissues are needed to assess overall health, whether from disease considerations or possibly from environmental contaminant exposures. Common and routine methods typically rely upon radioimmunoassays, which can be expensive, and typically only measure thyroxine and 3,3',5-triidothyronine, which can be a limitation in fully evaluating impacts on thyroid regulation. In this study we developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous analysis of five thyroid hormones--thyroxine, 3,3',5-triidothyronine, 3,3',5'-triiodothyronine, 3,3'-diiodothyronine, and 3,5-diiodothyronine--in serum samples. The LC-MS/MS parameters were optimized and calibrated over a wide concentration range (1.0-500 ng/mL) with on-column detection limits of 1.5-7.0 pg. With use of spiked bovine serum samples, the mean method recoveries were calculated to be 81.3-111.9% with relative standard deviations of 1.2-9.6% at spiking levels ranging from 10 to 100 ng/mL. This method was compared with measurements made by standard radioimmunoassays and with measurements made in a serum Standard Reference Material (SRM 1951b). Development of this method expands the capacity to measure thyroid hormones by including a larger suite of thyroid hormones, and has promising applications for measuring catabolism of thyroid hormones in vitro.
Collapse
|
52
|
|
53
|
Vila L, Serra-Prat M, Palomera E, Casamitjana R, de Castro A, Legaz G, Barrionuevo C, Garcia AJ, Lal-Trehan S, Muñoz JA, Durán J, Garcia A, Puig-Domingo M. Reference values for thyroid function tests in pregnant women living in Catalonia, Spain. Thyroid 2010; 20:221-5. [PMID: 20151832 DOI: 10.1089/thy.2008.0264] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
54
|
Felipe CL, Medina CC, Sieiro NL, Alexandru B, Mario V. Is an upper limit of 2.5 mUI/l for TSH appropriate for the first trimester of pregnancy among young TPO - women? Gynecol Endocrinol 2010; 26:54-7. [PMID: 19657813 DOI: 10.3109/09513590903159557] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
OBJECTIVES The general purpose of this study is to assess the distribution among the various hormonal indices in young pregnant women with negative thyroid peroxidase antibodies and iodine sufficiency and classify them accordingly while comparing them to literature proposed reference values for the first trimester. METHODS A sectional study was carried out, including 127 pregnant women enrolled at the prenatal outpatient clinic at the Nova Iguaçu General Hospital, in the period comprised between 2000 and June 2007. They were submitted to TSH, free T(4), total T(4), TBG, and thyroid peroxidase antibody determinations. RESULTS A median equal to 38.7 microg/ml was observed for TBG; TSH values varied between 0.02 and 5.84 mcUI/ml, with a median of 1.25 mcUI/ml. For total T(4) and free T(4), median values were, respectively 10.3 microg/dl and 1.20 ng/dl. Thirteen patients out of 115 displayed a TSH serum level above 2.5 mUI/ml. CONCLUSIONS Patients with subclinical hypothyroidism classified by this new cutoff (serum TSH concentration between 2.5 mUI/l and the upper limit of the reference range), chiefly ATPO-negative young women display no need for treatment as there is no evidence that this condition is associated with maternal and fetal complications.
Collapse
Affiliation(s)
- Castro Luiz Felipe
- Faculdade de Medicina/Serviço de Endocrinologia, Hospital Universitário Clementino Fraga Filho - UFRJ, Rio de Janeiro, Brazil
| | | | | | | | | |
Collapse
|
55
|
Soldin OP, Goughenour BE, Gilbert SZ, Landy HJ, Soldin SJ. Thyroid hormone levels associated with active and passive cigarette smoking. Thyroid 2009; 19:817-23. [PMID: 19505184 PMCID: PMC3643222 DOI: 10.1089/thy.2009.0023] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
BACKGROUND Active and passive cigarette smoking are a risk factor among women of reproductive age-leading to reproductive health morbidity, including fetal and infant death and developmental problems with the newborn. However, the underlying physiological mechanisms for these ill-effects are not fully understood. Smoke exposure may affect various metabolic and biological processes, including hormone biosynthesis and secretion, interfere with thyroid hormone release, binding, transport, storage, and clearance, associated with adverse effects on the thyroid resulting in changes in circulating hormone concentrations. We measured and compared serum thyroid hormone and thyroid stimulating hormone (TSH) concentrations in active, passive, and nonsmokers and determined their association with cigarette tobacco smoke exposure. We use a comprehensive approach to assess the interrelationships between active and passive tobacco smoke exposure and thyroid hormone levels by employing innovative hormone analysis techniques. METHODS Serum was obtained from women (18-44 years of age). Thyroxine (T4), triiodothyronine (T3), and cotinine concentrations were quantified using isotope dilution high performance liquid chromatography tandem mass spectrometry, and TSH concentrations by chemiluminescence. RESULTS Serum concentrations of the various hormones of active smokers, passive smokers, and nonsmokers (nonexposed), respectively, were as follows. Median TSH concentrations were 1.02, 1.06, and 1.12 mIU/L (p < 0.001 for the comparison of each group with the other two groups), and mean TSH levels were 1.40 mIU/L, confidence interval (CI) 0.07-6.83 mIU/L; 1.30 mIU/L, CI 0.25-3.01 mIU/L; and 1.50 mIU/mL, CI 0.71-4.00 mIU/L. Median serum T4 concentrations were 7.6, 7.9, and 8.7 microg/dL, and median serum T3 concentrations were 92.0, 84.0, and 102.0 ng/dL (p < 0.0001). Mean T3 levels were 99.1 ng/dL, CI 52.1-204.3 ng/dL; 87.6 ng/dL, CI 40.1-160.2 ng/dL; and 106.6 ng/dL, CI 46.4-175.0 ng/dL. Pair-wise comparisons of the three study groups indicate statistically significant differences in serum T4 (p < 0.01) and T3 (p < 0.001) means for the comparison of each group with the other two groups. CONCLUSIONS This study is unique in examining the association of serum cotinine and thyroid hormone concentrations using liquid chromatography tandem mass spectrometry in women smokers, passive smokers, and nonsmokers. Active and passive exposure to cigarette tobacco smoke is associated with a mild inhibitory effect on the thyroid reflected in higher serum T4 and T3 in nonsmokers compared to smokers in this cohort of women.
Collapse
Affiliation(s)
- Offie P Soldin
- Department of Oncology, Lombardi Comprehensive Cancer Center, Georgetown University Medical Center, Washington, District of Columbia 20057, USA.
| | | | | | | | | |
Collapse
|
56
|
Abstract
BACKGROUND The clinical value of free thyroxine (FT(4)) and free triiodothyronine (FT(3)) analysis depends on the reference intervals with which they are compared. We determined age- and sex-specific reference intervals for neonates, infants, and children 0-18 years of age for FT(4) and FT(3) using tandem mass spectrometry. METHODS Reference intervals were calculated for serum FT(4) (n = 1426) and FT(3) (n = 1107) obtained from healthy children between January 1, 2008, and June 30, 2008, from Children's National Medical Center and Georgetown University Medical Center Bioanalytical Core Laboratory, Washington, DC. Serum samples were analyzed using isotope dilution liquid chromatography tandem mass spectrometry (LC/MS/MS) with deuterium-labeled internal standards. RESULTS FT(4) reference intervals were very similar for males and females of all ages and ranged between 1.3 and 2.4 ng/dL for children 1 to 18 years old. FT(4) reference intervals for 1- to 12-month-old infants were 1.3-2.8 ng/dL. These 2.5 to 97.5 percentile intervals were much tighter than reference intervals obtained using immunoassay platforms 0.48-2.78 ng/dL for males and 0.85-2.09 ng/dL for females. Similarly, FT(3) intervals were consistent and similar for males and females and for all ages, ranging between 1.5 pg/mL and approximately 6.0 pg/mL for children 1 month of age to 18 years old. CONCLUSIONS This is the first study to provide pediatric reference intervals of FT(4) and FT(3) for children from birth to 18 years of age using LC/MS/MS. Analysis using LC/MS/MS provides more specific quantification of thyroid hormones. A comparison of the ultrafiltration tandem mass spectrometric method with equilibrium dialysis showed very good correlation.
Collapse
Affiliation(s)
- Offie P Soldin
- Department of Oncology, Georgetown University Medical Center, Washington, DC 20007, USA.
| | | | | | | |
Collapse
|
57
|
Jin H, Lin JM, Wang X, Xin TB, Liang SX, Li ZJ, Hu GM. Magnetic particle-based chemiluminescence enzyme immunoassay for free thyroxine in human serum. J Pharm Biomed Anal 2009; 50:891-6. [PMID: 19581068 DOI: 10.1016/j.jpba.2009.06.011] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2009] [Revised: 06/03/2009] [Accepted: 06/06/2009] [Indexed: 10/20/2022]
Abstract
A magnetic particles-based chemiluminescence enzyme immunoassay with high sensitivity, specificity, rapidity, and reproducibility was developed for the determination of free thyroxine in human serum. A competitive assay has been proposed with horseradish peroxidase labeled thyroxine analog. The immunomagnetic particles coated with anti-fluorescein isothiocyanate antibody was used as dispersed solid phase and separation means for the immunoassay. Experimental conditions, such as temperature, the volume of magnetic particles and substrate, incubation time, dilution ratio and other relevant variables upon the immunoassay have been examined and optimized. The proposed method exhibited high performance which the linear range was 1.59-122 pmol L(-1) and the detection limit was 0.25 pmol L(-1). A coefficient of variance of less than 15% was obtained for both intra-assay and inter-assay precision. The present method has been successfully applied to the analysis of free thyroxine in human serum. The diagnostic accordance rate of the method for normal serum, hyperthyroidism and hypothyroidism are satisfactory. Good correlations were obtained between the results by the proposed method and the commercial radioimmunoassay kit. The present method exhibits good potential in the fabrication of FT4 diagnostic kits which could be used in the clinical analysis and facilitated the development of automated operation systems in the clinical practice.
Collapse
Affiliation(s)
- Hui Jin
- The Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology, Department of Chemistry, Tsinghua University, Haidian, Beijing 100084, China
| | | | | | | | | | | | | |
Collapse
|
58
|
Jonklaas J, Kahric-Janicic N, Soldin OP, Soldin SJ. Correlations of free thyroid hormones measured by tandem mass spectrometry and immunoassay with thyroid-stimulating hormone across 4 patient populations. Clin Chem 2009; 55:1380-8. [PMID: 19460839 DOI: 10.1373/clinchem.2008.118752] [Citation(s) in RCA: 82] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND Accurate measurement of free thyroid hormones is important for managing thyroid disorders. Ultrafiltration liquid chromatography tandem mass spectrometry (LC-MS/MS) can reliably measure the concentrations of small molecules, including thyroid hormones. Our study was designed to compare free thyroid hormone measurements performed with immunoassay and LC-MS/MS. METHODS We studied the performance of LC-MS/MS in 4 different populations comprising pediatric patients, euthyroid adults, and healthy nonpregnant and pregnant women. The samples obtained from each population numbered 38, 200, 28, and 128, respectively. Free thyroxine, free triiodothyronine, and thyroid-stimulating hormone (TSH) concentrations were documented. RESULTS LC-MS/MS measurement of free thyroid hormones provided better correlation with log-transformed serum TSH in each population and also the populations combined. The correlations between free thyroxine measured by LC-MS/MS and log TSH in the pediatric outpatients and healthy adults were -0.90 and -0.77, respectively. The correlations for immunoassay were -0.82 and -0.48. The correlations between free triiodothyronine measured by LC-MS/MS and TSH for both pediatric and healthy adult populations were -0.72 and -0.68, respectively. CONCLUSIONS Free thyroid hormone concentrations measured by LC-MS/MS correlate to a greater degree with log TSH values compared to concentrations measured by immunoassay. This correlation was maintained across the patient populations we studied and may reflect the accuracy and specificity of LC-MS/MS. The superior ability of LC-MS/MS to enable documentation of the well-known thyroid hormone-TSH relationship supports the use of this measurement technique in a variety of clinical situations.
Collapse
Affiliation(s)
- Jacqueline Jonklaas
- Division of Endocrinology, Georgetown University Medical Center, Washington, DC 20007, USA.
| | | | | | | |
Collapse
|
59
|
Lee RH, Spencer CA, Mestman JH, Miller EA, Petrovic I, Braverman LE, Goodwin TM. Free T4 immunoassays are flawed during pregnancy. Am J Obstet Gynecol 2009; 200:260.e1-6. [PMID: 19114271 DOI: 10.1016/j.ajog.2008.10.042] [Citation(s) in RCA: 184] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2008] [Revised: 08/09/2008] [Accepted: 10/07/2008] [Indexed: 11/24/2022]
Abstract
OBJECTIVE The purpose of this study was to evaluate the diagnostic accuracies of 2 free thyroxine immunoassays during pregnancy. STUDY DESIGN Serum was collected from healthy, thyroid peroxidase antibody-negative women during each trimester and nonpregnant controls. Thyrotropin, total T4 (TT4), free T4 index (FT4I), and 2 different FT4 immunoassays were studied. RESULTS As expected, TT4 was elevated in all 3 trimesters compared to controls (P < .001). FT4I was elevated in the 1st trimester as compared with controls (P < .05) and returned to the nonpregnant range in the 2nd and 3rd trimesters. In contrast, 1st trimester FT4 immunoassay values were either comparable or lower than controls and by the 2nd and 3rd trimesters had decreased to approximately 65% of controls. CONCLUSION Neither FT4 immunoassay accurately reflects established free T4 changes during pregnancy. TT4 and the FT4I retained an appropriate inverse relationship with TSH throughout pregnancy and appear to provide a more reliable free T4 estimate.
Collapse
|
60
|
STOCKIGT JR. Obstetric implications of current Australian product information for thyroid-related medications. Aust N Z J Obstet Gynaecol 2009; 49:64-6. [DOI: 10.1111/j.1479-828x.2008.00944.x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
61
|
Abstract
BACKGROUND Our objective was to determine the performance of liquid chromatography-tandem mass spectrometry (LC-MS/MS) in documenting both group and individual relationships between thyroid hormone and thyroid-stimulating hormone (TSH) concentrations. METHODS This was a prospective analysis of 50 euthyroid patients undergoing thyroidectomy. Thyroxine (T(4)), triiodothyronine (T(3)), free T(4) (FT(4)), and TSH levels were documented on two occasions before thyroidectomy. After thyroidectomy, patients were treated with levothyroxine (LT(4)) to achieve either a normal or low serum TSH concentration. All laboratory evaluations were repeated twice while patients were taking LT(4). Thyroid hormone concentrations were documented by both immunoassay and LC-MS/MS, and their relationship with TSH was studied both in the entire group and in individual patients pre- and postthyroidectomy. RESULTS FT(4) and total T(3) correlated better with the log-transformed TSH when measured by LC-MS/MS. Postthyroidectomy the closest correlation was between log TSH and FT(4) (r = 0.86, p < 0.001). The next best correlation was between log TSH and total T(3) (r = 0.71, p < 0.001). When all data points were combined, the slope of the relationship between log TSH and total T(3) was relatively blunted compared with the log TSH-FT(4) slope (slope - 0.39 vs. - 1.38; p < 0.001), perhaps suggesting autoregulation of T(3) in response to the altered conditions postthyroidectomy. CONCLUSION LC-MS/MS is an excellent tool for documenting the known physiological phenomenon of a log-linear relationship between TSH and thyroid hormone concentrations. In a group of patients studied pre- and postthyroidectomy, both FT(4) and total T(3) measured by tandem mass spectrometry correlate well with TSH. However, T(3) correlates slightly less well and has a relatively blunted relationship with the log-transformed TSH. These paired data suggest that in LT(4)-replaced patients T(3) concentrations are held stable in the face of fluctuating T(4) concentrations.
Collapse
Affiliation(s)
- Jacqueline Jonklaas
- Division of Endocrinology, Georgetown University Medical Center, Washington, District of Columbia 20007, USA.
| | | |
Collapse
|
62
|
Sapin R. Interférences dans les immunodosages : mécanismes et conséquences en endocrinologie. ANNALES D'ENDOCRINOLOGIE 2008; 69:415-25. [DOI: 10.1016/j.ando.2008.04.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2007] [Revised: 04/08/2008] [Accepted: 04/21/2008] [Indexed: 10/22/2022]
|
63
|
Gong Y, Hoffman BR. Free thyroxine reference interval in each trimester of pregnancy determined with the Roche Modular E-170 electrochemiluminescent immunoassay. Clin Biochem 2008; 41:902-6. [DOI: 10.1016/j.clinbiochem.2008.04.009] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2008] [Revised: 04/08/2008] [Accepted: 04/09/2008] [Indexed: 10/22/2022]
|
64
|
Pearce EN, Oken E, Gillman MW, Lee SL, Magnani B, Platek D, Braverman LE. Association of first-trimester thyroid function test values with thyroperoxidase antibody status, smoking, and multivitamin use. Endocr Pract 2008; 14:33-9. [PMID: 18238739 DOI: 10.4158/ep.14.1.33] [Citation(s) in RCA: 86] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
OBJECTIVE To determine first-trimester thyroid function values and associations with thyroperoxidase antibody (TPO-Ab) status, smoking, emesis, and iodine-containing multivitamin use. METHODS We collected information by interview, questionnaire, and blood draw at the initial obstetric visit in 668 pregnant women without known thyroid disease. We compared thyroid-stimulating hormone (TSH), total thyroxine (T4), and free T4 index (FT4I) values by TPO-Ab status. Multiple regression was used to identify characteristics associated with thyroid function values. RESULTS The following median (range containing 95% of the data points) thyroid function test values were obtained in 585 TPO-Ab-negative women: TSH, 1.1 mIU/L (0.04-3.6); FT4I, 2.1 (1.5-2.9); and T4, 9.9 microg/dL (7.0-14.0). The following median (range containing 95% of the data points) thyroid function test values were obtained in 83 TPO-Ab-positive women: TSH, 1.8 mIU/L (0.3-6.4) (P<.001); FT4I, 2.0 (1.4-2.7) (P = .06); and T4, 9.3 microg/dL (6.8-13.0) (P = .03) (P values denote statistically significant differences between TPO-Ab-positive and negative participants). Among TPO-Ab-negative participants, TSH level was not associated with use of iodine-containing multivitamins, smoking, or race. TSH increased 0.03 mIU/L for every year of maternal age (P = .03) and decreased by 0.3 mIU/L for every increase in parity (P<.001). T4 decreased 0.04 microg/dL for every year of maternal age (P = .04). Mean FT4I was 2.05 in smokers and 2.20 in nonsmokers (P<.01). There were no relationships between T4 or FT4I and parity, race, or iodine-containing multivitamin use. CONCLUSION TPO-Ab status of pregnant women should be considered when constructing trimester-specific reference ranges because elevated serum TPO-Ab levels are associated with higher TSH and lower T4 values.
Collapse
Affiliation(s)
- Elizabeth N Pearce
- Section of Endocrinology, Diabetes, and Nutrition, Boston University Medical Center, Boston, Massachusetts, USA.
| | | | | | | | | | | | | |
Collapse
|
65
|
Yue B, Rockwood AL, Sandrock T, La'ulu SL, Kushnir MM, Meikle AW. Free thyroid hormones in serum by direct equilibrium dialysis and online solid-phase extraction--liquid chromatography/tandem mass spectrometry. Clin Chem 2008; 54:642-51. [PMID: 18258669 DOI: 10.1373/clinchem.2007.098293] [Citation(s) in RCA: 83] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
BACKGROUND Measurements of free thyroxine (FT4) and free triiodothyronine (FT3) are important for the diagnosis and monitoring of thyroid diseases. Considerable differences among methods limit their clinical utility, however, and accurate methods are needed for various clinical specimens. We describe a direct equilibrium dialysis (ED)-liquid chromatography (LC)/tandem mass spectrometry (MS/MS) method for FT4 and FT3. METHODS ED was selected as the separation step. Serum samples were dialyzed 1:1 against a simple protein-free buffer for 20 h at 37 degrees C. Thyroid hormones in dialysates were purified by online solid-phase extraction (SPE), then chromatographically separated and quantified in positive ion and multiple reaction monitoring modes. RESULTS For FT4 and FT3, the lower and upper limits of quantification were 1 ng/L (pg/mL) and 400 ng/L with total imprecision <10%. The method correlated well with an ED-RIA, 2 direct immunoassay methods for FT4, and 1 direct immunoassay and 1 tracer dialysis method for FT3. The adult reference intervals were 12.8-22.2 ng/L for FT4 and 3.62-6.75 ng/L for FT3. Reference intervals for the second trimester of pregnancy (14-20 weeks of gestation) were also established. CONCLUSIONS We developed a simple protein-free buffer and ED procedure. The performance characteristics and high throughput of the LC-MS/MS method with online SPE for FT4 and FT3 (also reverse T3) are sufficient for the intended clinical use.
Collapse
Affiliation(s)
- Bingfang Yue
- ARUP Institute for Clinical and Experimental Pathology, Salt Lake City, UT 84108-1221, USA.
| | | | | | | | | | | |
Collapse
|
66
|
Soldin OP, Soldin D, Sastoque M. Gestation-specific thyroxine and thyroid stimulating hormone levels in the United States and worldwide. Ther Drug Monit 2007; 29:553-9. [PMID: 17898643 PMCID: PMC3635539 DOI: 10.1097/ftd.0b013e31815709ac] [Citation(s) in RCA: 56] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
BACKGROUND Euthyroid women experience dramatic changes in the demand for thyroid hormone production as early as the first trimester of pregnancy. These changes are important for fetal neurodevelopment and organ development as well as maternal health and succesful full term pregnancy. Therefore, gestation-specific reference intervals assist in appropriate clinical management of thyroid disease in pregnancy to ensure maternal and fetal health. OBJECTIVE To determine trimester-specific levels of serum thyroxine (T4) and thyroid stimulating hormone (TSH) in the U.S. population based on the National Health and Nutrition Survey III and compare these with published trimester-specific T4 and TSH means and medians obtained in other countries worldwide. METHODS Trimester-specific means and medians for T4 and TSH were determined for the U.S. population based on the National Health and Nutrition Survey III database (1988-1994). These were compared with trimester-specific means and medians of other countries in the published literature. RESULTS Mean serum T4 levels for the U.S. population were 141.35, 152.95, and 142.65 nmol/L in the three trimesters, respectively, whereas mean serum TSH levels were 0.91, 1.03, and 1.32 mIU/L. CONCLUSIONS Gestation-specific mean T4 and TSH levels for the representative U.S. population are well within the trimester-specific reference intervals. T4 and TSH measured during pregnancy in longitudinal and cross-sectional studies of populations worldwide demonstrate that, in some populations, T4 and TSH levels are outside the normal trimester-specific reference intervals.
Collapse
Affiliation(s)
- Offie P Soldin
- Department of Oncology, Center for Sex Differences, Washington, DC, USA.
| | | | | |
Collapse
|
67
|
Abstract
Laboratory tests are the most commonly used aids in the diagnosis and monitoring of individuals who have thyroid disease. This article briefly summarizes the common methods of laboratory testing relating to thyroid disease and discusses specific information for individual tests on methods of analysis, their limitations, and situations where caution should be used in interpreting the results of thyroid tests.
Collapse
Affiliation(s)
- D Robert Dufour
- Pathology and Laboratory Medicine Service, Veterans Affairs Medical Center, and George Washington University Medical Center, 2300 Eye Street, NW, Washington, DC 20037, USA.
| |
Collapse
|
68
|
Gu J, Soldin OP, Soldin SJ. Simultaneous quantification of free triiodothyronine and free thyroxine by isotope dilution tandem mass spectrometry. Clin Biochem 2007; 40:1386-91. [PMID: 17936741 DOI: 10.1016/j.clinbiochem.2007.08.007] [Citation(s) in RCA: 81] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2007] [Revised: 07/31/2007] [Accepted: 08/07/2007] [Indexed: 11/16/2022]
Abstract
OBJECTIVES This study was designed to improve our previously developed tandem mass spectrometry (MS/MS) method for free thyroxine (FT4) by enhancing sensitivity and permitting simultaneous measurements of both free triidothyronine (FT3) and FT4 using a smaller plasma/serum sample. DESIGN AND METHODS An API-5,000 tandem mass spectrometer equipped with TurboIonSpray source and Shimadzu HPLC system was employed to perform the analysis using isotope dilution with deuterium labeled internal standard, T4-d(5). Four hundred microliters of human plasma/serum was filtered through a Centrifree YM-30 ultrafiltration device by centrifugation, and 450 microL of internal standard in methanol was then added to 150 microL of ultrafiltrate for deproteinization. After centrifugation, 500 microL of supernatant was diluted with 400 microL of distilled de-ionized water and a 650 microL aliquot was injected onto a C-18 column. After washing, the switching valve was activated and the analytes were eluted from the column with a water/methanol gradient into the MS/MS system. Quantification by multiple reaction-monitoring (MRM) analysis was performed in the negative mode. RESULTS The within-day and between-day coefficients of variation (CVs) were <or=9% for FT3 and <or=7% for FT4 at all concentrations tested. Accuracy ranged between 95% and 105%. The 2.5th-97.5th percentile for FT3 and FT4 was 0.09-0.4 ng/dL (1.4-6.2 pmol/L) and 0.8-2.1 ng/dL (10-26 pmol/L), respectively. The results correlated only moderately well with the immunoassays. CONCLUSIONS We describe an improved simple, accurate and fast isotope dilution tandem mass spectrometry method for the simultaneous determination of FT3 and FT4 in human serum/plasma samples.
Collapse
Affiliation(s)
- Jianghong Gu
- Department of Laboratory Medicine, Children's National Medical Center, 111 Michigan Avenue, NW, Washington, DC, USA
| | | | | |
Collapse
|
69
|
Wang X, Chen H, Lin JM, Ying X. Development of a highly sensitive and selective microplate chemiluminescence enzyme immunoassay for the determination of free thyroxine in human serum. Int J Biol Sci 2007; 3:274-80. [PMID: 17505537 PMCID: PMC1865090 DOI: 10.7150/ijbs.3.274] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2007] [Accepted: 04/17/2007] [Indexed: 11/21/2022] Open
Abstract
A microplate chemiluminescence enzyme immunoassay (CLEIA) with high sensitivity, selectivity and reproducibility was developed for the determination of free thyroxine (FT4) in human serum. A competitive assay has been utilized with horseradish peroxidase (HRP) labeled thyroxine analog in the chemiluminescence (CL) detection. The CL signal produced by the emission of photons from luminol was directly proportional to the amount of analyte. The linear range was 0.45-7.5 ng dL-1 and the detection limit was 0.09 ng dL-1. Experimental conditions, such as temperature, pH, incubation time, titration level and other relevant variables upon the CL signal have been examined and optimized. A coefficient of variance of less than 16% was obtained for intra- and inter-assay precision. The present method has been successfully applied to the analysis of FT4 in human serum. The positive and negative coincidence ratios are satisfactory. Good correlations were obtained between the results by the proposed method and radioimmunoassay (RIA), as well as a Bayer ACS-180SE detection system.
Collapse
Affiliation(s)
- Xu Wang
- 1. The Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology, Department of Chemistry, Tsinghua University, Beijing, 100084, China
| | - Hui Chen
- 1. The Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology, Department of Chemistry, Tsinghua University, Beijing, 100084, China
| | - Jin-Ming Lin
- 1. The Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology, Department of Chemistry, Tsinghua University, Beijing, 100084, China
| | - Xitang Ying
- 2. Beijing Chemclin Biotech Co., Ltd., Beijing Academy of Science and Technology, Haidian, Beijing, 100094, China
| |
Collapse
|
70
|
Luebker DJ, York RG, Hansen KJ, Moore JA, Butenhoff JL. Neonatal mortality from in utero exposure to perfluorooctanesulfonate (PFOS) in Sprague-Dawley rats: dose-response, and biochemical and pharamacokinetic parameters. Toxicology 2005; 215:149-69. [PMID: 16129535 DOI: 10.1016/j.tox.2005.07.019] [Citation(s) in RCA: 224] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2005] [Revised: 07/19/2005] [Accepted: 07/20/2005] [Indexed: 11/25/2022]
Abstract
Perfluorooctanesulfonate (PFOS) is a widely distributed, environmentally persistent acid found at low levels in human, wildlife, and environmental media samples. Neonatal mortality has been observed following PFOS exposure in a two-generation reproduction study in rats and after dosing pregnant rats and mice during gestation. Objectives of the current study were to better define the dose-response curve for neonatal mortality in rat pups born to PFOS-exposed dams and to investigate biochemical and pharmacokinetic parameters potentially related to the etiology of effects observed in neonatal rat pups. In the current study, additional doses of 0.8, 1.0, 1.2, and 2.0 mg/kg/day were included with original doses used in the two-generation study of 0.4 and 1.6 mg/kg/day in order to obtain data in the critical range of the dose-response curve. Biochemical parameters investigated in dams and litters included: (1) serum lipids, glucose, mevalonic acid, and thyroid hormones; (2) milk cholesterol; and (3) liver lipids. Pharmacokinetic parameters investigated included the interrelationship of administered oral dose of PFOS to maternal body burden of PFOS and the transfer of maternal body burden to the fetus in utero and pup during lactation, as these factors may affect neonatal toxicity. Dosing of dams occurred for 6 weeks prior to mating with untreated breeder males, through confirmed mating, gestation, and day four of lactation. Dose levels for the dose-response and etiological investigation were 0.0, 0.4, 0.8, 1.0, 1.2, 1.6, and 2.0 mg/kg/day PFOS. Statistically significant decreases in gestation length were observed in the 0.8 mg/kg and higher dose groups. Decreases in viability through lactation day 5 were observed in the 0.8 mg/kg and higher dose groups, becoming statistically significant in the 1.6 and 2.0 mg/kg dose groups. Reduced neonatal survival did not appear to be the result of reductions in lipids, glucose utilization, or thyroid hormones. The endpoints of gestation length and decreased viability were positively correlated, suggesting that late-stage fetal development may be affected in pups exposed to PFOS in utero and may contribute to the observed mortality. Benchmark dose (BMD) estimates for decreased gestation length, birth weight, pup weight on lactation day 5, pup weight gain through lactation day 5, and viability resulted in values ranging from 0.27 to 0.89mg/kg/day for the lower 95% confidence limit of the BMD5 (BMDL5). Results of analyses for PFOS in biological matrices indicate a linear proportionality of mean serum PFOS concentration to maternal administered dose prior to mating and through the first two trimesters of gestation. However, at 21 days of gestation, mean serum PFOS concentrations were notably reduced from values measured earlier in gestation. Urinary and fecal elimination was low as expected from prior observations in adult rats. Significant transfer of PFOS from dam to fetus in utero was confirmed, and results suggest that dam and corresponding fetal body burdens, as indicated by serum and liver PFOS levels, correlate with neonatal survival.
Collapse
Affiliation(s)
- Deanna J Luebker
- 3M Medical Department, Corporate Toxicology and Regulatory Services, 3M Center Building 220-06-E-03, St. Paul, MN 55144, USA.
| | | | | | | | | |
Collapse
|
71
|
Soldin OP, Hilakivi-Clarke L, Weiderpass E, Soldin SJ. Trimester-specific reference intervals for thyroxine and triiodothyronine in pregnancy in iodine-sufficient women using isotope dilution tandem mass spectrometry and immunoassays. Clin Chim Acta 2005; 349:181-9. [PMID: 15469872 PMCID: PMC3625638 DOI: 10.1016/j.cccn.2004.06.021] [Citation(s) in RCA: 61] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2004] [Revised: 06/24/2004] [Accepted: 06/24/2004] [Indexed: 11/24/2022]
Abstract
BACKGROUND Accurate assessment of the pregnant woman's thyroid status is critical, for both the initiation of thyroid hormone therapy and for the adjustment of thyroid hormone dose in those already receiving thyroid hormone. Trimester-specific intervals are especially important during pregnancy when thyroid insufficiency may be associated with adverse obstetric outcome and fetal neurodevelopmental deficits. We defined pregnancy-specific reference intervals for thyroxine (T4) and 3,5,3'-triiodothyronine (T3). We used a novel isotope dilution tandem mass spectrometry (LC/MS/MS) method, and compare these to reference intervals obtained by immunoassays (IAs) performed on the same samples. METHODS Concentrations of circulating T4 and T3 were measured simultaneously during first, second and third trimesters and postpartum in iodine-sufficient, healthy, singleton pregnancies using API-3000 LC/MS/MS with deuterium-labeled internal standard (L-thyroxine-d2). Immunoassays were conducted on the same samples (T4 Dade Behring RxL, T3 DPC-Immunolite). RESULTS Linear regression is reported for method comparisons; for T4, the slope decreased from r=0.900 in nonpregnant women to 0.802-0.820 during pregnancy. For T3, correlations between LC/MS/MS and immunoassays were weaker in all cases (r=0.407-0.574). CONCLUSION In this longitudinal study, we established trimester-specific reference intervals for T4 and T3 by LC/MS/MS and compare these to intervals obtained by immunoassays.
Collapse
Affiliation(s)
- O P Soldin
- Division of Cancer Genetics and Epidemiology, Lombardi Cancer Center, Georgetown University Medical Center, Room S-165-A, Washington, DC 20007-2197, USA.
| | | | | | | |
Collapse
|
72
|
Abstract
A workshop entitled, "The Impact of Maternal Thyroid Diseases on the Developing Fetus: Implications for Diagnosis, Treatment, and Screening," was held in Atlanta, Georgia, January 12-13, 2004. The workshop was sponsored jointly by The National Center on Birth Defects and Developmental Disabilities of The Centers for Disease Control and Prevention (CDC) and The American Thyroid Association. This paper reports on the individual session that examined the ability to detect and treat thyroid dysfunction during pregnancy. For this session, presented papers included: "Laboratory Reference Values in Pregnancy" and "Criteria for Diagnosis and Treatment of Hypothyroidism in Pregnancy." These presentations were formally discussed by invited respondents and by others in attendance. Salient points from this session about which there was agreement include the following: thyrotropin (TSH) can be used as marker for hypothyroidism in pregnancy, except when there is iodine deficiency usually evidenced by elevated serum thyroglobulin (Tg). We need more longitudinal studies of TSH during pregnancy in iodine-sufficient populations without evidence of autoimmune thyroid disease to develop trimester-specific TSH reference ranges. Current free thyroxine (FT4) estimate methods are sensitive to abnormal binding-protein states such as pregnancy. There is no absolute FT4 value that will define hypothyroxinemia across methods. Total thyroxine (TT4) changes in pregnancy are predictable and not method-specific. TT4 below 100 nmol/L (7.8 microg/dL) is a reasonable indicator of hypothyroxinemia in pregnancy. Women with known hypothyroidism and receiving levothyroxine (LT4) before pregnancy should plan to increase their dosage by 30% to 60% early in pregnancy. Women with autoimmune thyroid disease prior to pregnancy are at increased risk for thyroid insufficiency during pregnancy and postpartum thyroiditis and should be monitored with TSH during pregnancy.
Collapse
Affiliation(s)
- Susan J Mandel
- Division of Endocrinology, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | | | | |
Collapse
|