51
|
Lafond M, Aptel F, Mestas JL, Lafon C. Ultrasound-mediated ocular delivery of therapeutic agents: a review. Expert Opin Drug Deliv 2016; 14:539-550. [DOI: 10.1080/17425247.2016.1198766] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Maxime Lafond
- Inserm, LabTAU, Lyon, France
- Univ Lyon, Université Lyon 1, Lyon, France
| | - Florent Aptel
- Department of Ophthalmology, University Hospital of Grenoble, Université Grenoble Alpes, Grenoble, France
| | - Jean-Louis Mestas
- Inserm, LabTAU, Lyon, France
- Univ Lyon, Université Lyon 1, Lyon, France
| | - Cyril Lafon
- Inserm, LabTAU, Lyon, France
- Univ Lyon, Université Lyon 1, Lyon, France
| |
Collapse
|
52
|
Aw MS, Paniwnyk L, Losic D. The progressive role of acoustic cavitation for non-invasive therapies, contrast imaging and blood-tumor permeability enhancement. Expert Opin Drug Deliv 2016; 13:1383-96. [PMID: 27195384 DOI: 10.1080/17425247.2016.1192123] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
INTRODUCTION Drug delivery pertaining to acoustic cavitation generated from ultrasonic (US) irradiation is advantageous for devising smarter and more advanced therapeutics. The aim is to showcase microbubbles as drug carriers and robust theranostic for non-invasive therapies across diverse biomedical disciplines, highlighting recent technologies in this field for overcoming the blood-brain barrier (BBB) to treat cancers and neurological disorders. AREAS COVERED This article reviews work on the optimized tuning of ultrasonic parameters, sonoporation, transdermal and responsive drug delivery, acoustic cavitation in vasculature and oncology, contrast imaging for real-time magnification of cell-microbubble dynamics and biomolecular targeting. Scholarly literature was sought through database search on key terminology, latest topics, reputable experts and established journals over the last five years. EXPERT OPINION Cavitation offers immense promise in overcoming current diffusion and convection limitations for treating skull/brain/vascular/tissue injuries and ablating tumors to minimize chronic/acute effects. Since stable cavitation facilitates the restoration of US-opened BBB and the modulation of drug concentration, US equipment with programmable imaging modality and sensitivity are envisaged to create safer miniaturized devices for personalized care. Due to differing biomedical protocols with regard to specific medical conditions, quantitative and qualitative controls are mandatory before translation to real-life clinical applications can be accomplished.
Collapse
Affiliation(s)
- Moom Sinn Aw
- a School of Chemical Engineering , The University of Adelaide , Adelaide , Australia.,b Faculty of Health and Life Sciences , Coventry University , West Midlands , UK
| | - Larysa Paniwnyk
- c Faculty of Health and Life Sciences , Coventry University , West Midlands , UK
| | - Dusan Losic
- a School of Chemical Engineering , The University of Adelaide , Adelaide , Australia
| |
Collapse
|
53
|
Anderson CA, Hare MA, Perdrizet GA. Wound Healing Devices Brief Vignettes. Adv Wound Care (New Rochelle) 2016; 5:185-190. [PMID: 27076996 DOI: 10.1089/wound.2015.0651] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
Significance: The demand for wound care therapies is increasing. New wound care products and devices are marketed at a dizzying rate. Practitioners must make informed decisions about the use of medical devices for wound healing therapy. This paper provides updated evidence and recommendations based on a review of recent publications. Recent Advances: The published literature on the use of medical devices for wound healing continues to support the use of hyperbaric oxygen therapy, negative pressure wound therapy, and most recently electrical stimulation. Critical Issue: To inform wound healing practitioners of the evidence for or against the use of medical devices for wound healing. This information will aid the practitioner in deciding which technology should be accepted or rejected for clinical use. Future Directions: To produce high quality, randomized controlled trials or acquire outcome-based registry databases to further test and improve the knowledge base as it relates to the use of medical devices in wound care.
Collapse
Affiliation(s)
- Caesar A. Anderson
- Department of Emergency Medicine, Centers for Wound Healing and Hyperbaric Medicine, University of California, San Diego, San Diego, California
| | - Marc A. Hare
- Department of Emergency Medicine, Centers for Wound Healing and Hyperbaric Medicine, University of California, San Diego, San Diego, California
| | - George A. Perdrizet
- Department of Emergency Medicine, Centers for Wound Healing and Hyperbaric Medicine, University of California, San Diego, San Diego, California
| |
Collapse
|
54
|
Zhou Y, Wang YN, Farr N, Zia J, Chen H, Ko BM, Khokhlova T, Li T, Hwang JH. Enhancement of Small Molecule Delivery by Pulsed High-Intensity Focused Ultrasound: A Parameter Exploration. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:956-63. [PMID: 26803389 PMCID: PMC4775378 DOI: 10.1016/j.ultrasmedbio.2015.12.009] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2015] [Revised: 12/09/2015] [Accepted: 12/11/2015] [Indexed: 05/05/2023]
Abstract
Chemotherapeutic drug delivery is often ineffective within solid tumors, but increasing the drug dose would result in systemic toxicity. The use of high-intensity focused ultrasound (HIFU) has the potential to enhance penetration of small molecules. However, operation parameters need to be optimized before the use of chemotherapeutic drugs in vivo and translation to clinical trials. In this study, the effects of pulsed HIFU (pHIFU) parameters (spatial-average pulse-average intensity, duty factor and pulse repetition frequency) on the penetration as well as content of small molecules were evaluated in ex vivo porcine kidneys. Specific HIFU parameters resulted in more than 40 times greater Evans blue content and 3.5 times the penetration depth compared with untreated samples. When selected parameters were applied to porcine kidneys in vivo, a 2.3-fold increase in concentration was obtained after a 2-min exposure to pHIFU. Pulsed HIFU has been found to be an effective modality to enhance both the concentration and penetration depth of small molecules in tissue using the optimized HIFU parameters. Although, performed in normal tissue, this study has the promise of translation into tumor tissue.
Collapse
Affiliation(s)
- Yufeng Zhou
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore
| | - Yak-Nam Wang
- Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, Seattle, Washington, USA.
| | - Navid Farr
- Department of Bioengineering, University of Washington, Seattle, Washington, USA
| | - Jasmine Zia
- Division of Gastroenterology, School of Medicine, University of Washington, Seattle, Washington, USA
| | - Hong Chen
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, Missouri, USA
| | - Bong Min Ko
- Digestive Disease Center and Research Institute, Department of Internal Medicine, Soonchunhyang University College of Medicine, Asan, Korea
| | - Tatiana Khokhlova
- Division of Gastroenterology, School of Medicine, University of Washington, Seattle, Washington, USA
| | - Tong Li
- Department of Bioengineering, University of Washington, Seattle, Washington, USA
| | - Joo Ha Hwang
- Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, Seattle, Washington, USA; Division of Gastroenterology, School of Medicine, University of Washington, Seattle, Washington, USA
| |
Collapse
|
55
|
Theek B, Baues M, Ojha T, Möckel D, Veettil SK, Steitz J, van Bloois L, Storm G, Kiessling F, Lammers T. Sonoporation enhances liposome accumulation and penetration in tumors with low EPR. J Control Release 2016; 231:77-85. [PMID: 26878973 DOI: 10.1016/j.jconrel.2016.02.021] [Citation(s) in RCA: 120] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2015] [Revised: 02/04/2016] [Accepted: 02/10/2016] [Indexed: 12/22/2022]
Abstract
The Enhanced Permeability and Retention (EPR) effect is a highly variable phenomenon. To enhance EPR-mediated passive drug targeting to tumors, several different pharmacological and physical strategies have been evaluated over the years, including e.g. TNFα-treatment, vascular normalization, hyperthermia and radiotherapy. Here, we systematically investigated the impact of sonoporation, i.e. the combination of ultrasound (US) and microbubbles (MB), on the tumor accumulation and penetration of liposomes. Two different MB formulations were employed, and their ability to enhance liposome accumulation and penetration was evaluated in two different tumor models, which are both characterized by relatively low levels of EPR (i.e. highly cellular A431 epidermoid xenografts and highly stromal BxPC-3 pancreatic carcinoma xenografts). The liposomes were labeled with two different fluorophores, enabling in vivo computed tomography/fluorescence molecular tomography (CT-FMT) and ex vivo two-photon laser scanning microscopy (TPLSM). In both models, in spite of relatively high inter- and intra-individual variability, a trend towards improved liposome accumulation and penetration was observed. In treated tumors, liposome concentrations were up to twice as high as in untreated tumors, and sonoporation enhanced the ability of liposomes to extravasate out of the blood vessels into the tumor interstitium. These findings indicate that sonoporation may be a useful strategy for improving drug targeting to tumors with low EPR.
Collapse
Affiliation(s)
- Benjamin Theek
- Department of Experimental Molecular Imaging, University Clinic and Helmholtz Institute for Biomedical Engineering, RWTH-Aachen University, Aachen, Germany
| | - Maike Baues
- Department of Experimental Molecular Imaging, University Clinic and Helmholtz Institute for Biomedical Engineering, RWTH-Aachen University, Aachen, Germany
| | - Tarun Ojha
- Department of Experimental Molecular Imaging, University Clinic and Helmholtz Institute for Biomedical Engineering, RWTH-Aachen University, Aachen, Germany
| | - Diana Möckel
- Department of Experimental Molecular Imaging, University Clinic and Helmholtz Institute for Biomedical Engineering, RWTH-Aachen University, Aachen, Germany
| | - Seena Koyadan Veettil
- Institute for Laboratory Animal Science, University Clinic, RWTH-Aachen University, Aachen, Germany
| | - Julia Steitz
- Institute for Laboratory Animal Science, University Clinic, RWTH-Aachen University, Aachen, Germany
| | - Louis van Bloois
- Department of Pharmaceutics, Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Utrecht, The Netherlands
| | - Gert Storm
- Department of Pharmaceutics, Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Utrecht, The Netherlands; Department of Targeted Therapeutics, MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, The Netherlands
| | - Fabian Kiessling
- Department of Experimental Molecular Imaging, University Clinic and Helmholtz Institute for Biomedical Engineering, RWTH-Aachen University, Aachen, Germany.
| | - Twan Lammers
- Department of Experimental Molecular Imaging, University Clinic and Helmholtz Institute for Biomedical Engineering, RWTH-Aachen University, Aachen, Germany; Department of Pharmaceutics, Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Utrecht, The Netherlands; Department of Targeted Therapeutics, MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, The Netherlands.
| |
Collapse
|
56
|
Patra S, Roy E, Madhuri R, Sharma PK. Retracted Article: Creation of ultrasound and temperature-triggered bubble liposomes from economical precursors to enhance the therapeutic efficacy of curcumin in cancer cells. RSC Adv 2016. [DOI: 10.1039/c6ra14584a] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
An ultrasound and temperature responsive bubble liposome has been designed with high physiological stability, targeted, rapid and tunable drug release profile.
Collapse
Affiliation(s)
- Santanu Patra
- Department of Applied Chemistry
- Indian School of Mines
- Dhanbad
- India
| | - Ekta Roy
- Department of Applied Chemistry
- Indian School of Mines
- Dhanbad
- India
| | - Rashmi Madhuri
- Department of Applied Chemistry
- Indian School of Mines
- Dhanbad
- India
| | - Prashant K. Sharma
- Functional Nanomaterials Research Laboratory
- Department of Applied Physics
- Indian School of Mines
- Dhanbad
- India
| |
Collapse
|
57
|
Uusi-Kerttula H, Hulin-Curtis S, Davies J, Parker AL. Oncolytic Adenovirus: Strategies and Insights for Vector Design and Immuno-Oncolytic Applications. Viruses 2015; 7:6009-42. [PMID: 26610547 PMCID: PMC4664994 DOI: 10.3390/v7112923] [Citation(s) in RCA: 61] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2015] [Revised: 11/13/2015] [Accepted: 11/17/2015] [Indexed: 02/06/2023] Open
Abstract
Adenoviruses (Ad) are commonly used both experimentally and clinically, including oncolytic virotherapy applications. In the clinical area, efficacy is frequently hampered by the high rates of neutralizing immunity, estimated as high as 90% in some populations that promote vector clearance and limit bioavailability for tumor targeting following systemic delivery. Active tumor targeting is also hampered by the ubiquitous nature of the Ad5 receptor, hCAR, as well as the lack of highly tumor-selective targeting ligands and suitable targeting strategies. Furthermore, significant off-target interactions between the viral vector and cellular and proteinaceous components of the bloodstream have been documented that promote uptake into non-target cells and determine dose-limiting toxicities. Novel strategies are therefore needed to overcome the obstacles that prevent efficacious Ad deployment for wider clinical applications. The use of less seroprevalent Ad serotypes, non-human serotypes, capsid pseudotyping, chemical shielding and genetic masking by heterologous peptide incorporation are all potential strategies to achieve efficient vector escape from humoral immune recognition. Conversely, selective vector arming with immunostimulatory agents can be utilized to enhance their oncolytic potential by activation of cancer-specific immune responses against the malignant tissues. This review presents recent advantages and pitfalls occurring in the field of adenoviral oncolytic therapies.
Collapse
Affiliation(s)
- Hanni Uusi-Kerttula
- Institute of Cancer and Genetics, School of Medicine, Cardiff University, Heath Park, Cardiff CF14 4XN, UK.
| | - Sarah Hulin-Curtis
- Institute of Cancer and Genetics, School of Medicine, Cardiff University, Heath Park, Cardiff CF14 4XN, UK.
| | - James Davies
- Institute of Cancer and Genetics, School of Medicine, Cardiff University, Heath Park, Cardiff CF14 4XN, UK.
| | - Alan L Parker
- Institute of Cancer and Genetics, School of Medicine, Cardiff University, Heath Park, Cardiff CF14 4XN, UK.
| |
Collapse
|
58
|
Kwan JJ, Myers R, Coviello CM, Graham SM, Shah AR, Stride E, Carlisle RC, Coussios CC. Ultrasound-Propelled Nanocups for Drug Delivery. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2015; 11:5305-14. [PMID: 26296985 PMCID: PMC4660885 DOI: 10.1002/smll.201501322] [Citation(s) in RCA: 161] [Impact Index Per Article: 16.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2015] [Revised: 07/14/2015] [Indexed: 05/20/2023]
Abstract
Ultrasound-induced bubble activity (cavitation) has been recently shown to actively transport and improve the distribution of therapeutic agents in tumors. However, existing cavitation-promoting agents are micron-sized and cannot sustain cavitation activity over prolonged time periods because they are rapidly destroyed upon ultrasound exposure. A novel ultrasound-responsive single-cavity polymeric nanoparticle (nanocup) capable of trapping and stabilizing gas against dissolution in the bloodstream is reported. Upon ultrasound exposure at frequencies and intensities achievable with existing diagnostic and therapeutic systems, nanocups initiate and sustain readily detectable cavitation activity for at least four times longer than existing microbubble constructs in an in vivo tumor model. As a proof-of-concept of their ability to enhance the delivery of unmodified therapeutics, intravenously injected nanocups are also found to improve the distribution of a freely circulating IgG mouse antibody when the tumor is exposed to ultrasound. Quantification of the delivery distance and concentration of both the nanocups and coadministered model therapeutic in an in vitro flow phantom shows that the ultrasound-propelled nanocups travel further than the model therapeutic, which is itself delivered to hundreds of microns from the vessel wall. Thus nanocups offer considerable potential for enhanced drug delivery and treatment monitoring in oncological and other biomedical applications.
Collapse
Affiliation(s)
- James J Kwan
- Institute of Biomedical Engineering, University of OxfordOxford, OX3 7DQ, UK E-mail:
| | - Rachel Myers
- Institute of Biomedical Engineering, University of OxfordOxford, OX3 7DQ, UK E-mail:
| | - Christian M Coviello
- Institute of Biomedical Engineering, University of OxfordOxford, OX3 7DQ, UK E-mail:
| | - Susan M Graham
- Institute of Biomedical Engineering, University of OxfordOxford, OX3 7DQ, UK E-mail:
| | - Apurva R Shah
- Institute of Biomedical Engineering, University of OxfordOxford, OX3 7DQ, UK E-mail:
- Department of Oncology, University of OxfordOxford, OX3 7DQ, UK
| | - Eleanor Stride
- Institute of Biomedical Engineering, University of OxfordOxford, OX3 7DQ, UK E-mail:
| | - Robert C Carlisle
- Institute of Biomedical Engineering, University of OxfordOxford, OX3 7DQ, UK E-mail:
| | - Constantin C Coussios
- Institute of Biomedical Engineering, University of OxfordOxford, OX3 7DQ, UK E-mail:
| |
Collapse
|
59
|
Novel delivery approaches for cancer therapeutics. J Control Release 2015; 219:248-268. [PMID: 26456750 DOI: 10.1016/j.jconrel.2015.09.067] [Citation(s) in RCA: 105] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2015] [Revised: 09/09/2015] [Accepted: 09/30/2015] [Indexed: 02/07/2023]
Abstract
Currently, a majority of cancer treatment strategies are based on the removal of tumor mass mainly by surgery. Chemical and physical treatments such as chemo- and radiotherapies have also made a major contribution in inhibiting rapid growth of malignant cells. Furthermore, these approaches are often combined to enhance therapeutic indices. It is widely known that surgery, chemo- and radiotherapy also inhibit normal cells growth. In addition, these treatment modalities are associated with severe side effects and high toxicity which in turn lead to low quality of life. This review encompasses novel strategies for more effective chemotherapeutic delivery aiming to generate better prognosis. Currently, cancer treatment is a highly dynamic field and significant advances are being made in the development of novel cancer treatment strategies. In contrast to conventional cancer therapeutics, novel approaches such as ligand or receptor based targeting, triggered release, intracellular drug targeting, gene delivery, cancer stem cell therapy, magnetic drug targeting and ultrasound-mediated drug delivery, have added new modalities for cancer treatment. These approaches have led to selective detection of malignant cells leading to their eradication with minimal side effects. Lowering multi-drug resistance and involving influx transportation in targeted drug delivery to cancer cells can also contribute significantly in the therapeutic interventions in cancer.
Collapse
|
60
|
Owen J, Rademeyer P, Chung D, Cheng Q, Holroyd D, Coussios C, Friend P, Pankhurst QA, Stride E. Magnetic targeting of microbubbles against physiologically relevant flow conditions. Interface Focus 2015; 5:20150001. [PMID: 26442137 PMCID: PMC4549839 DOI: 10.1098/rsfs.2015.0001] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
The localization of microbubbles to a treatment site has been shown to be essential to their effectiveness in therapeutic applications such as targeted drug delivery and gene therapy. A variety of different strategies for achieving localization has been investigated, including biochemical targeting, acoustic radiation force, and the incorporation of superparamagnetic nanoparticles into microbubbles to enable their manipulation using an externally applied magnetic field. The third of these strategies has the advantage of concentrating microbubbles in a target region without exposing them to ultrasound, and can be used in conjunction with biochemical targeting to achieve greater specificity. Magnetic microbubbles have been shown to be effective for therapeutic delivery in vitro and in vivo. Whether this technique can be successfully applied in humans however remains an open question. The aim of this study was to determine the range of flow conditions under which targeting could be achieved. In vitro results indicate that magnetic microbubbles can be retained using clinically acceptable magnetic fields, for both the high shear rates (approx. 104 s−1) found in human arterioles and capillaries, and the high flow rates (approx. 3.5 ml s−1) of human arteries. The potential for human in vivo microbubble retention was further demonstrated using a perfused porcine liver model.
Collapse
Affiliation(s)
- Joshua Owen
- Institute of Biomedical Engineering, Department of Engineering Science , University of Oxford , Old Road Campus Research Building, Oxford OX3 7DQ , UK
| | - Paul Rademeyer
- Institute of Biomedical Engineering, Department of Engineering Science , University of Oxford , Old Road Campus Research Building, Oxford OX3 7DQ , UK
| | - Daniel Chung
- Institute of Biomedical Engineering, Department of Engineering Science , University of Oxford , Old Road Campus Research Building, Oxford OX3 7DQ , UK ; Nuffield Department of Surgical Sciences , University of Oxford , John Radcliffe Hospital, Oxford OX3 9DU , UK
| | - Qian Cheng
- Institute of Biomedical Engineering, Department of Engineering Science , University of Oxford , Old Road Campus Research Building, Oxford OX3 7DQ , UK
| | - David Holroyd
- Institute of Biomedical Engineering, Department of Engineering Science , University of Oxford , Old Road Campus Research Building, Oxford OX3 7DQ , UK ; Nuffield Department of Surgical Sciences , University of Oxford , John Radcliffe Hospital, Oxford OX3 9DU , UK
| | - Constantin Coussios
- Institute of Biomedical Engineering, Department of Engineering Science , University of Oxford , Old Road Campus Research Building, Oxford OX3 7DQ , UK
| | - Peter Friend
- Nuffield Department of Surgical Sciences , University of Oxford , John Radcliffe Hospital, Oxford OX3 9DU , UK
| | - Quentin A Pankhurst
- Healthcare Biomagnetics Laboratory , University College London , 21 Albemarle Street, London W1S 4BS , UK ; Institute of Biomedical Engineering , University College London , Gower Street, London WC1E 6BT , UK
| | - Eleanor Stride
- Institute of Biomedical Engineering, Department of Engineering Science , University of Oxford , Old Road Campus Research Building, Oxford OX3 7DQ , UK
| |
Collapse
|
61
|
Prieur F, Pialoux V, Mestas JL, Mury P, Skinner S, Lafon C. Evaluation of inertial cavitation activity in tissue through measurement of oxidative stress. ULTRASONICS SONOCHEMISTRY 2015; 26:193-199. [PMID: 25818361 DOI: 10.1016/j.ultsonch.2015.03.011] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2015] [Revised: 03/02/2015] [Accepted: 03/16/2015] [Indexed: 06/04/2023]
Abstract
Ultrasound cavitation is an essential mechanism involved in the therapeutic local enhancement of drug delivery by ultrasound for cancer treatment. Inertial cavitation also triggers chemical reactions that generate free radicals and subsequent oxidative stress in the tissue. The aim of this study was to measure the oxidative stress induced by inertial cavitation in ex vivo tissue and to test the association between the exposure conditions and the oxidative stress. A confocal ultrasound setup was used to sonicate and create inertial cavitation in freshly excised adipose pig tissue. The ex vivo tissue samples were then processed to measure the quantity of malondialdehyde (MDA), an end-product of polyunsaturated free fatty acid oxidation. The creation of hydroxyterephthalic acid (HTA) from the reaction of terephthalic acid (TA) with free radicals in water was also quantified in vitro. Samples were sonicated for different durations using various amplitudes for the applied pressure. The results showed a minimum 2-fold increase in the amount of detected MDA in the sonicated tissue samples compared to baseline clearly suggesting the generation of free radicals by inertial cavitation. The method exhibited a moderate dependence of MDA generated upon the duration of exposure (R(2)=057,p<0.0001). The average increase in MDA concentration was approximately 2-fold, 5-fold, 6-fold, and 9-fold for exposure durations per unit of volume of 0.13, 0.17, 0.25, and 0.50s/mm(3), respectively. The results showed no statistically significant dependence on the amplitude of the pressure within the used range. Both pressure amplitude and exposure duration, however, influenced the HTA concentration (R(2)>0.95,p<0.0001). This biochemical method can be used on ex vivo tissue to detect the generation of free radicals induced by inertial cavitation. In large enough sample populations, the cavitation activity is linked to the exposure conditions of the sonication.
Collapse
Affiliation(s)
- Fabrice Prieur
- Inserm, U1032, LabTau, Lyon F-69003, France; Université de Lyon, Lyon F-69003, France.
| | - Vincent Pialoux
- CRIS EA647, Université Lyon 1, 27-29 Boulevard du 11 novembre 1918, 69622 Villeurbanne Cedex, France
| | - Jean-Louis Mestas
- Inserm, U1032, LabTau, Lyon F-69003, France; Université de Lyon, Lyon F-69003, France
| | - Pauline Mury
- CRIS EA647, Université Lyon 1, 27-29 Boulevard du 11 novembre 1918, 69622 Villeurbanne Cedex, France
| | - Sarah Skinner
- CRIS EA647, Université Lyon 1, 27-29 Boulevard du 11 novembre 1918, 69622 Villeurbanne Cedex, France
| | - Cyril Lafon
- Inserm, U1032, LabTau, Lyon F-69003, France; Université de Lyon, Lyon F-69003, France
| |
Collapse
|
62
|
Yu T, Luo L, Wang L. Ultrasound as a cancer chemotherapy sensitizer: the gap between laboratory and bedside. Expert Opin Drug Deliv 2015; 13:37-47. [PMID: 26328944 DOI: 10.1517/17425247.2015.1083008] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
63
|
Mo S, Carlisle R, Laga R, Myers R, Graham S, Cawood R, Ulbrich K, Seymour L, Coussios CC. Increasing the density of nanomedicines improves their ultrasound-mediated delivery to tumours. J Control Release 2015; 210:10-8. [PMID: 25975831 DOI: 10.1016/j.jconrel.2015.05.265] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2015] [Revised: 05/06/2015] [Accepted: 05/10/2015] [Indexed: 12/18/2022]
Abstract
Nanomedicines have provided fresh impetus in the fight against cancer due to their selectivity and power. However, these agents are limited when delivered intravenously due to their rapid clearance from the bloodstream and poor passage from the bloodstream into target tumours. Here we describe a novel stealthing strategy which addresses both these limitations and thereby demonstrate that both the passive and mechanically-mediated tumour accumulation of the model nanomedicine adenovirus (Ad) can be substantially enhanced. In our strategy gold nanoparticles were thoroughly modified with 2kDa polyethyleneglycol (PEG) and then linked to Ad via a single reduction-cleavable 5kDa PEG. The resulting Ad-gold-PEG construct was compared to non-modified Ad or conventionally stealthed Ad-poly[N-(2-hydroxypropyl)methacrylamide] (Ad-PHPMA). Notably, although Ad-gold-PEG was of similar size and surface charge to Ad-PHPMA the increase in density, resulting from the inclusion of the gold nanoparticles, provided a substantial enhancement of ultrasound-mediated transport. In an in vitro tumour mimicking phantom, the level and distance of Ad-gold-PEG transport was shown to be substantially greater than achieved with Ad-PHPMA. In in vivo studies 0.1% of an unmodified Ad dose was shown to accumulate in tumours, whereas over 12% of the injected dose was recovered from the tumours of mice treated with Ad-gold-PEG and ultrasound. Ultimately, a significant increase in anti-tumour efficacy resulted from this strategy. This stealthing and density-increasing technology could ultimately enhance clinical utility of intravenously delivered nanoscale medicines including viruses, liposomes and antibodies.
Collapse
Affiliation(s)
- Steven Mo
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Old Road Campus Research Building, Oxford OX3 7DQ, UK
| | - Robert Carlisle
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Old Road Campus Research Building, Oxford OX3 7DQ, UK.
| | - Richard Laga
- Clinical Pharmacology, Department of Oncology, University of Oxford, Old Road Campus Research Building, Oxford OX3 7DQ, UK; Institute of Macromolecular Chemistry, Czech Academy of Sciences, Prague, Czech Republic
| | - Rachel Myers
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Old Road Campus Research Building, Oxford OX3 7DQ, UK
| | - Susan Graham
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Old Road Campus Research Building, Oxford OX3 7DQ, UK
| | - Ryan Cawood
- Clinical Pharmacology, Department of Oncology, University of Oxford, Old Road Campus Research Building, Oxford OX3 7DQ, UK
| | - Karel Ulbrich
- Institute of Macromolecular Chemistry, Czech Academy of Sciences, Prague, Czech Republic
| | - Leonard Seymour
- Clinical Pharmacology, Department of Oncology, University of Oxford, Old Road Campus Research Building, Oxford OX3 7DQ, UK
| | - Constantin-C Coussios
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Old Road Campus Research Building, Oxford OX3 7DQ, UK
| |
Collapse
|
64
|
Kunjachan S, Ehling J, Storm G, Kiessling F, Lammers T. Noninvasive Imaging of Nanomedicines and Nanotheranostics: Principles, Progress, and Prospects. Chem Rev 2015; 115:10907-37. [PMID: 26166537 DOI: 10.1021/cr500314d] [Citation(s) in RCA: 317] [Impact Index Per Article: 31.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- Sijumon Kunjachan
- Department of Nanomedicines and Theranostics, Institute for Experimental Molecular Imaging (ExMI), University Clinic and Helmholtz Institute for Biomedical Engineering, RWTH Aachen University , Pauwelsstrasse 30, 52074 Aachen, Germany
| | - Josef Ehling
- Department of Nanomedicines and Theranostics, Institute for Experimental Molecular Imaging (ExMI), University Clinic and Helmholtz Institute for Biomedical Engineering, RWTH Aachen University , Pauwelsstrasse 30, 52074 Aachen, Germany
| | - Gert Storm
- Department of Targeted Therapeutics, MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente , P.O. Box 217, 7500 AE, Enschede, The Netherlands.,Department of Pharmaceutics, Utrecht Institute for Pharmaceutical Sciences (UIPS), Utrecht University , Universiteitsweg 99, 3584 CG Utrecht, The Netherlands
| | - Fabian Kiessling
- Department of Nanomedicines and Theranostics, Institute for Experimental Molecular Imaging (ExMI), University Clinic and Helmholtz Institute for Biomedical Engineering, RWTH Aachen University , Pauwelsstrasse 30, 52074 Aachen, Germany
| | - Twan Lammers
- Department of Nanomedicines and Theranostics, Institute for Experimental Molecular Imaging (ExMI), University Clinic and Helmholtz Institute for Biomedical Engineering, RWTH Aachen University , Pauwelsstrasse 30, 52074 Aachen, Germany.,Department of Targeted Therapeutics, MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente , P.O. Box 217, 7500 AE, Enschede, The Netherlands.,Department of Pharmaceutics, Utrecht Institute for Pharmaceutical Sciences (UIPS), Utrecht University , Universiteitsweg 99, 3584 CG Utrecht, The Netherlands
| |
Collapse
|
65
|
Prieur F, Zorgani A, Catheline S, Souchon R, Mestas JL, Lafond M, Lafon C. Observation of a cavitation cloud in tissue using correlation between ultrafast ultrasound images. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2015; 62:1256-64. [PMID: 26168172 DOI: 10.1109/tuffc.2014.006905] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
The local application of ultrasound is known to improve drug intake by tumors. Cavitating bubbles are one of the contributing effects. A setup in which two ultrasound transducers are placed confocally is used to generate cavitation in ex vivo tissue. As the transducers emit a series of short excitation bursts, the evolution of the cavitation activity is monitored using an ultrafast ultrasound imaging system. The frame rate of the system is several thousands of images per second, which provides several tens of images between consecutive excitation bursts. Using the correlation between consecutive images for speckle tracking, a decorrelation of the imaging signal appears due to the creation, fast movement, and dissolution of the bubbles in the cavitation cloud. By analyzing this area of decorrelation, the cavitation cloud can be localized and the spatial extent of the cavitation activity characterized.
Collapse
|
66
|
Durymanov MO, Rosenkranz AA, Sobolev AS. Current Approaches for Improving Intratumoral Accumulation and Distribution of Nanomedicines. Theranostics 2015; 5:1007-20. [PMID: 26155316 PMCID: PMC4493538 DOI: 10.7150/thno.11742] [Citation(s) in RCA: 130] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2015] [Accepted: 05/09/2015] [Indexed: 12/22/2022] Open
Abstract
The ability of nanoparticles and macromolecules to passively accumulate in solid tumors and enhance therapeutic effects in comparison with conventional anticancer agents has resulted in the development of various multifunctional nanomedicines including liposomes, polymeric micelles, and magnetic nanoparticles. Further modifications of these nanoparticles have improved their characteristics in terms of tumor selectivity, circulation time in blood, enhanced uptake by cancer cells, and sensitivity to tumor microenvironment. These "smart" systems have enabled highly effective delivery of drugs, genes, shRNA, radioisotopes, and other therapeutic molecules. However, the resulting therapeutically relevant local concentrations of anticancer agents are often insufficient to cause tumor regression and complete elimination. Poor perfusion of inner regions of solid tumors as well as vascular barrier, high interstitial fluid pressure, and dense intercellular matrix are the main intratumoral barriers that impair drug delivery and impede uniform distribution of nanomedicines throughout a tumor. Here we review existing methods and approaches for improving tumoral uptake and distribution of nano-scaled therapeutic particles and macromolecules (i.e. nanomedicines). Briefly, these strategies include tuning physicochemical characteristics of nanomedicines, modulating physiological state of tumors with physical impacts or physiologically active agents, and active delivery of nanomedicines using cellular hitchhiking.
Collapse
|
67
|
Coviello C, Kozick R, Choi J, Gyöngy M, Jensen C, Smith PP, Coussios CC. Passive acoustic mapping utilizing optimal beamforming in ultrasound therapy monitoring. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2015; 137:2573-85. [PMID: 25994690 DOI: 10.1121/1.4916694] [Citation(s) in RCA: 81] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Passive acoustic mapping (PAM) is a promising imaging method that enables real-time three-dimensional monitoring of ultrasound therapy through the reconstruction of acoustic emissions passively received on an array of ultrasonic sensors. A passive beamforming method is presented that provides greatly improved spatial accuracy over the conventionally used time exposure acoustics (TEA) PAM reconstruction algorithm. Both the Capon beamformer and the robust Capon beamformer (RCB) for PAM are suggested as methods to reduce interference artifacts and improve resolution, which has been one of the experimental issues previously observed with TEA. Simulation results that replicate the experimental artifacts are shown to suggest that bubble interactions are the chief cause. Analysis is provided to show that these multiple bubble artifacts are generally not reduced by TEA, while Capon-based methods are able to reduce the artifacts. This is followed by experimental results from in vitro experiments and in vivo oncolytic viral therapy trials that show improved results in PAM, where RCB is able to more accurately localize the acoustic activity than TEA.
Collapse
Affiliation(s)
- Christian Coviello
- Institute of Biomedical Engineering, University of Oxford, Oxford OX3 7DQ, United Kingdom
| | - Richard Kozick
- Department of Electrical Engineering, Bucknell University, Lewisburg, Pennsylvania 17837, USA
| | - James Choi
- Department of Bioengineering, Imperial College London, London SW7 2AZ, United Kingdom
| | - Miklós Gyöngy
- Faculty of Information and Technology and Bionics, Pázmány Péter Catholic University, Budapest, Hungary
| | - Carl Jensen
- Institute of Biomedical Engineering, University of Oxford, Oxford OX3 7DQ, United Kingdom
| | - Penny Probert Smith
- Institute of Biomedical Engineering, University of Oxford, Oxford OX3 7DQ, United Kingdom
| | - Constantin-C Coussios
- Institute of Biomedical Engineering, University of Oxford, Oxford OX3 7DQ, United Kingdom
| |
Collapse
|
68
|
Li T, Khokhlova T, Wang YN, Maloney E, D'Andrea S, Starr F, Farr N, Morrison K, Keilman G, Hwang JH. Endoscopic high-intensity focused US: technical aspects and studies in an in vivo porcine model (with video). Gastrointest Endosc 2015; 81:1243-50. [PMID: 25759124 PMCID: PMC4452137 DOI: 10.1016/j.gie.2014.12.019] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/29/2014] [Accepted: 12/04/2014] [Indexed: 02/08/2023]
Abstract
BACKGROUND High-intensity focused US (HIFU) is becoming more widely used for noninvasive and minimally invasive ablation of benign and malignant tumors. Recent studies suggest that HIFU can also enhance targeted drug delivery and stimulate an antitumor immune response in many tumors. However, targeting pancreatic and liver tumors by using an extracorporeal source is challenging due to the lack of an adequate acoustic window. The development of an EUS-guided HIFU transducer has many potential benefits including improved targeting, decreased energy requirements, and decreased potential for injury to intervening structures. OBJECTIVE To design, develop, and test an EUS-guided HIFU transducer for endoscopic applications. DESIGN A preclinical, pilot characterization and feasibility study. SETTING Academic research center. PATIENTS Studies were performed in an in vivo porcine model. INTERVENTION Thermal ablation of in vivo porcine pancreas and liver was performed with EUS-guided focused US through the gastric tract. RESULTS The transducer successfully created lesions in gel phantoms and ex vivo bovine livers. In vivo studies demonstrated that targeting and creating lesions in the porcine pancreas and liver are feasible. LIMITATIONS This was a preclinical, single-center feasibility study with a limited number of subjects. CONCLUSION An EUS-guided HIFU transducer was successfully designed and developed with dimensions that are appropriate for endoscopic use. The feasibility of performing EUS-guided HIFU ablation in vivo was demonstrated in an in vivo porcine model. Further development of this technology will allow endoscopists to perform precise therapeutic ablation of periluminal lesions without breaching the wall of the gastric tract.
Collapse
Affiliation(s)
- Tong Li
- Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, Seattle WA 98105
| | - Tatiana Khokhlova
- Division of Gastroenterology, Department of Medicine, Applied Physics Laboratory, University of Washington, Seattle WA
| | - Yak-Nam Wang
- Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, Seattle WA
| | - Ezekiel Maloney
- Department of Radiology, University of Washington, Seattle WA
| | - Samantha D'Andrea
- Division of Gastroenterology, Department of Medicine, University of Washington, Seattle WA
| | - Frank Starr
- Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, Seattle WA
| | - Navid Farr
- Department of Bioengineering, University of Washington, Seattle WA
| | | | | | - Joo Ha Hwang
- Division of Gastroenterology, Department of Medicine, University of Washington, Seattle WA
| |
Collapse
|
69
|
Feiszthuber H, Bhatnagar S, Gyöngy M, Coussios CC. Cavitation-enhanced delivery of insulin in agar and porcine models of human skin. Phys Med Biol 2015; 60:2421-34. [PMID: 25716689 DOI: 10.1088/0031-9155/60/6/2421] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Ultrasound-assisted transdermal insulin delivery offers a less painful and less invasive alternative to subcutaneous insulin injections. However, ultrasound-based drug delivery, otherwise known as sonophoresis, is a highly variable phenomenon, in part dependent on cavitation. The aim of the current work is to investigate the role of cavitation in transdermal insulin delivery. Fluorescently stained, soluble Actrapid insulin was placed on the surface of human skin-mimicking materials subjected to 265 kHz, 10% duty cycle focused ultrasound. A confocally and coaxially aligned 5 MHz broadband ultrasound transducer was used to detect cavitation. Two different skin models were used. The first model, 3% agar hydrogel, was insonated with a range of pressures (0.25-1.40 MPa peak rarefactional focal pressure-PRFP), with and without cavitation nuclei embedded within the agar at a concentration of 0.05% w/v. The second, porcine skin was insonated at 1.00 and 1.40 MPa PRFP. In both models, fluorescence measurements were used to determine penetration depth and concentration of delivered insulin. Results show that in agar gel, both insulin penetration depth and concentration only increased significantly in the presence of inertial cavitation, with up to a 40% enhancement. In porcine skin the amount of fluorescent insulin was higher in the epidermis of those samples that were exposed to ultrasound compared to the control samples, but there was no significant increase in penetration distance. The results underline the importance of instigating and monitoring inertial cavitation during transdermal insulin delivery.
Collapse
Affiliation(s)
- Helga Feiszthuber
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, UK. Faculty of Information Technology and Bionics, Pázmány Péter Catholic University, Budapest, Hungary
| | | | | | | |
Collapse
|
70
|
Ultrasound as a method to enhance antitumor ability of oncolytic herpes simplex virus for head and neck cancer. Cancer Gene Ther 2015; 22:163-8. [PMID: 25656776 DOI: 10.1038/cgt.2015.3] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2014] [Revised: 12/26/2014] [Accepted: 12/29/2014] [Indexed: 11/08/2022]
Abstract
Low-intensity ultrasound is a useful method to enhance the delivery of drugs to target cells via a range of mechanisms including the transient formation of micropores in the cell membrane, a process known as sonoporation. The effect of ultrasound on oncolytic herpes simplex virus type-1 (HSV-1) infection in oral squamous cell carcinoma (SCC) was examined. Human SCC cell line SAS and oncolytic HSV-1 RH2, which was deficient in the neurovirulent γ134.5 gene and exhibited cell fusion actions, were used. Cells grown in multi-well plates were infected with HSV-1 and exposed to ultrasound in the presence or absence of microbubbles after an adsorption period. The number of plaques was significantly greater than that of the untreated control. SAS cells were inoculated subcutaneously into nude mice and tumors were produced. Tumors were injected with HSV-1 RH2 with or without microbubbles and then exposed to ultrasound through the covering skin. The amount of the virus in tumor tissues 3 days after the injection was higher in tumors treated with HSV-1 RH2 and ultrasound than in tumors treated with RH2 only. The expression of the HSV-1 antigen was also increased by ultrasound and microbubbles. Tumor growth was suppressed with HSV-1 RH2 in combination with ultrasound, especially with microbubbles. These results indicated that ultrasound increased the efficiency of the HSV-1 infection in SAS cells and nude mouse tumors. This method can potentially be useful to enhance the antitumor effects of oncolytic HSV-1 on head and neck cancer treatment.
Collapse
|
71
|
Liu J, Detrembleur C, Mornet S, Jérôme C, Duguet E. Design of hybrid nanovehicles for remotely triggered drug release: an overview. J Mater Chem B 2015; 3:6117-6147. [DOI: 10.1039/c5tb00664c] [Citation(s) in RCA: 90] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
This review addresses the advantages of remote triggers, e.g. ultrasounds, near infrared light and alternating magnetic fields, the fabrication of the hybrid nanovehicles, the release mechanisms and the next challenges.
Collapse
Affiliation(s)
- Ji Liu
- Centre for Education and Research on Macromolecules (CERM)
- University of Liege
- Chemistry Department
- B-4000 Liège
- Belgium
| | - Christophe Detrembleur
- Centre for Education and Research on Macromolecules (CERM)
- University of Liege
- Chemistry Department
- B-4000 Liège
- Belgium
| | | | - Christine Jérôme
- Centre for Education and Research on Macromolecules (CERM)
- University of Liege
- Chemistry Department
- B-4000 Liège
- Belgium
| | | |
Collapse
|
72
|
Schleich N, Danhier F, Préat V. Iron oxide-loaded nanotheranostics: Major obstacles to in vivo studies and clinical translation. J Control Release 2015; 198:35-54. [DOI: 10.1016/j.jconrel.2014.11.024] [Citation(s) in RCA: 64] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2014] [Revised: 11/21/2014] [Accepted: 11/22/2014] [Indexed: 12/14/2022]
|
73
|
Li Y, Peng B, Chen Y. Kinetically Trapped Block Copolymer Nano-Objects with Cylinder to Sphere Shape Transition Properties. MACROMOL CHEM PHYS 2014. [DOI: 10.1002/macp.201400505] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Yuyan Li
- Laboratory of Polymer Physics and Chemistry; Institute of Chemistry; The Chinese Academy of Sciences; Zhongguancun North First Street 2 Beijing 100190 P.R.China
| | - Bo Peng
- School of Chemistry and Chemical Engineering; Key Laboratory for Polymeric Composite and Functional Materials of Ministry of Education; Sun Yat-sen University; No. 135, Xingang Xi Road Guangzhou 510275 P.R.China
| | - Yongming Chen
- Laboratory of Polymer Physics and Chemistry; Institute of Chemistry; The Chinese Academy of Sciences; Zhongguancun North First Street 2 Beijing 100190 P.R.China
- School of Chemistry and Chemical Engineering; Key Laboratory for Polymeric Composite and Functional Materials of Ministry of Education; Sun Yat-sen University; No. 135, Xingang Xi Road Guangzhou 510275 P.R.China
| |
Collapse
|
74
|
Hauert S, Bhatia SN. Mechanisms of cooperation in cancer nanomedicine: towards systems nanotechnology. Trends Biotechnol 2014; 32:448-55. [PMID: 25086728 PMCID: PMC4295824 DOI: 10.1016/j.tibtech.2014.06.010] [Citation(s) in RCA: 65] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2014] [Revised: 06/26/2014] [Accepted: 06/27/2014] [Indexed: 02/07/2023]
Abstract
Nanoparticles are designed to deliver therapeutics and diagnostics selectively to tumors. Their size, shape, charge, material, coating, and cargo determine their individual functionalities. A systems approach could help predict the behavior of trillions of nanoparticles interacting in complex tumor environments. Engineering these nanosystems may lead to biomimetic strategies where interactions between nanoparticles and their environment give rise to cooperative behaviors typically seen in natural self-organized systems. Examples include nanoparticles that communicate the location of a tumor to amplify tumor homing or self-assemble and disassemble to optimize nanoparticle transport. The challenge is to discover which nanoparticle designs lead to a desired system behavior. To this end, novel nanomaterials, deep understanding of biology, and computational tools are emerging as the next frontier.
Collapse
Affiliation(s)
- Sabine Hauert
- Harvard-MIT Division of Health Sciences and Technology, Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Engineering Mathematics, University of Bristol, Bristol BS8 1TR, UK
| | - Sangeeta N Bhatia
- Harvard-MIT Division of Health Sciences and Technology, Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Department of Medicine, Brigham and Women's Hospital, Boston, MA 02115, USA; Howard Hughes Medical Institute, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
| |
Collapse
|
75
|
Li T, Chen H, Khokhlova T, Wang YN, Kreider W, He X, Hwang JH. Passive cavitation detection during pulsed HIFU exposures of ex vivo tissues and in vivo mouse pancreatic tumors. ULTRASOUND IN MEDICINE & BIOLOGY 2014; 40:1523-34. [PMID: 24613635 PMCID: PMC4048799 DOI: 10.1016/j.ultrasmedbio.2014.01.007] [Citation(s) in RCA: 68] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2013] [Revised: 12/17/2013] [Accepted: 01/06/2014] [Indexed: 05/03/2023]
Abstract
Pulsed high-intensity focused ultrasound (pHIFU) has been shown to enhance vascular permeability, disrupt tumor barriers and enhance drug penetration into tumor tissue through acoustic cavitation. Monitoring of cavitation activity during pHIFU treatments and knowing the ultrasound pressure levels sufficient to reliably induce cavitation in a given tissue are therefore very important. Here, three metrics of cavitation activity induced by pHIFU and evaluated by confocal passive cavitation detection were introduced: cavitation probability, cavitation persistence and the level of the broadband acoustic emissions. These metrics were used to characterize cavitation activity in several ex vivo tissue types (bovine tongue and liver and porcine adipose tissue and kidney) and gel phantoms (polyacrylamide and agarose) at varying peak-rare factional focal pressures (1-12 MPa) during the following pHIFU protocol: frequency 1.1 MHz, pulse duration 1 ms and pulse repetition frequency 1 Hz. To evaluate the relevance of the measurements in ex vivo tissue, cavitation metrics were also investigated and compared in the ex vivo and in vivo murine pancreatic tumors that develop spontaneously in transgenic KrasLSL.G12 D/+; p53 R172 H/+; PdxCretg/+ (KPC) mice and closely re-capitulate human disease in their morphology. The cavitation threshold, defined at 50% cavitation probability, was found to vary broadly among the investigated tissues (within 2.5-10 MPa), depending mostly on the water-lipid ratio that characterizes the tissue composition. Cavitation persistence and the intensity of broadband emissions depended both on tissue structure and lipid concentration. Both the cavitation threshold and broadband noise emission level were similar between ex vivo and in vivo pancreatic tumor tissue. The largest difference between in vivo and ex vivo settings was found in the pattern of cavitation occurrence throughout pHIFU exposure: it was sporadic in vivo, but it decreased rapidly and stopped over the first few pulses ex vivo. Cavitation activity depended on the interplay between the destruction and circulation of cavitation nuclei, which are not only used up by HIFU treatment but also replenished or carried away by circulation in vivo. These findings are important for treatment planning and optimization in pHIFU-induced drug delivery, in particular for pancreatic tumors.
Collapse
Affiliation(s)
- Tong Li
- Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, Seattle, WA, USA.
| | - Hong Chen
- Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, Seattle, WA, USA
| | - Tatiana Khokhlova
- Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, Seattle, WA, USA; Division of Gastroenterology, Department of Medicine, University of Washington, Seattle, WA, USA
| | - Yak-Nam Wang
- Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, Seattle, WA, USA
| | - Wayne Kreider
- Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, Seattle, WA, USA
| | - Xuemei He
- Department of Ultrasound Imaging, The First Affiliated Hospital, Chongqing Medical University, Chongqing, China
| | - Joo Ha Hwang
- Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, Seattle, WA, USA; Division of Gastroenterology, Department of Medicine, University of Washington, Seattle, WA, USA
| |
Collapse
|
76
|
He H, Huang H, Yu T. Detection of DNA damage in sonochemotherapy against cisplatin-resistant human ovarian cancer cells using the modified comet assay. Int J Radiat Biol 2014; 90:897-902. [PMID: 24827854 DOI: 10.3109/09553002.2014.922721] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
77
|
Ultrasound induced cancer immunotherapy. Adv Drug Deliv Rev 2014; 72:144-53. [PMID: 24680708 DOI: 10.1016/j.addr.2014.03.004] [Citation(s) in RCA: 85] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2013] [Revised: 02/14/2014] [Accepted: 03/18/2014] [Indexed: 12/21/2022]
Abstract
Recently, the use of ultrasound (US) has been shown to have potential in cancer immunotherapy. High intensity focused US destruction of tumors may lead to immunity forming in situ in the body by immune cells being exposed to the tumor debris and immune stimulatory substances that are present in the tumor remains. Another way of achieving anti-cancer immune responses is by using US in combination with microbubbles and nanobubbles to deliver genes and antigens into cells. US leads to bubble destruction and the forces released to direct delivery of the substances into the cytoplasm of the cells thus circumventing the natural barriers. In this way tumor antigens and antigen-encoding genes can be delivered to immune cells and immune response stimulating genes can be delivered to cancer cells thus enhancing immune responses. Combination of bubbles with cell-targeting ligands and US provides an even more sophisticated delivery system whereby the therapy is not only site specific but also cell specific. In this review we describe how US has been used to achieve immunity and discuss the potential and possible obstacles in future development.
Collapse
|
78
|
Ultrasound-guided tissue fractionation by high intensity focused ultrasound in an in vivo porcine liver model. Proc Natl Acad Sci U S A 2014; 111:8161-6. [PMID: 24843132 DOI: 10.1073/pnas.1318355111] [Citation(s) in RCA: 82] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
The clinical use of high intensity focused ultrasound (HIFU) therapy for noninvasive tissue ablation has been recently gaining momentum. In HIFU, ultrasound energy from an extracorporeal source is focused within the body to ablate tissue at the focus while leaving the surrounding organs and tissues unaffected. Most HIFU therapies are designed to use heating effects resulting from the absorption of ultrasound by tissue to create a thermally coagulated treatment volume. Although this approach is often successful, it has its limitations, such as the heat sink effect caused by the presence of a large blood vessel near the treatment area or heating of the ribs in the transcostal applications. HIFU-induced bubbles provide an alternative means to destroy the target tissue by mechanical disruption or, at its extreme, local fractionation of tissue within the focal region. Here, we demonstrate the feasibility of a recently developed approach to HIFU-induced ultrasound-guided tissue fractionation in an in vivo pig model. In this approach, termed boiling histotripsy, a millimeter-sized boiling bubble is generated by ultrasound and further interacts with the ultrasound field to fractionate porcine liver tissue into subcellular debris without inducing further thermal effects. Tissue selectivity, demonstrated by boiling histotripsy, allows for the treatment of tissue immediately adjacent to major blood vessels and other connective tissue structures. Furthermore, boiling histotripsy would benefit the clinical applications, in which it is important to accelerate resorption or passage of the ablated tissue volume, diminish pressure on the surrounding organs that causes discomfort, or insert openings between tissues.
Collapse
|
79
|
Yin T, Wang P, Li J, Wang Y, Zheng B, Zheng R, Cheng D, Shuai X. Tumor-penetrating codelivery of siRNA and paclitaxel with ultrasound-responsive nanobubbles hetero-assembled from polymeric micelles and liposomes. Biomaterials 2014; 35:5932-43. [PMID: 24746965 DOI: 10.1016/j.biomaterials.2014.03.072] [Citation(s) in RCA: 123] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2014] [Accepted: 03/27/2014] [Indexed: 02/07/2023]
Abstract
Drug resistance is a big problem in systemic chemotherapy of hepatocellular carcinoma (HCC), and nanomedicines loaded with both chemotherapeutic agents (e.g. paclitaxel, PTX) and siRNA's targeting antiapoptosis genes (e.g. BCL-2) possess the advantages to simultaneously overcome the efflux pump-mediated drug resistance and antiapoptosis-related drug resistance. However, tumor-penetrating drug delivery with this type of nanomedicines is extremely difficult due to their relatively big size compared to the single drug-loaded nanomedicines. Aiming at address this problem, US-responsive nanobubbles encapsulating both anti-cancer drug paclitaxel (PTX) and siRNA (PTX-NBs/siRNA) for HCC treatment were developed by hetero-assembly of polymeric micelles and liposomes in the present study. Utilizing an external low-frequency US force imposed to the tumor site, effective tumor-penetrating codelivery of siRNA and PTX was achieved via tail vein injection of PTX-NBs/siRNA into nude mice bearing human HepG2 xerografts. Consequently, the PTX treatment-inducible antiapoptosis in HepG2 cells was effectively suppressed by the codelivered siRNA targeting an antiapoptosis gene (BCL-2 siRNA) during chemotherapy. Owing to the synergistic anti-cancer effect of two therapeutic agents, tumor growth was completely inhibited using low-dose PTX in animal study. Our results highlight the great potential of this type of US-responsive hetero-assemblies carrying both anti-cancer drug and siRNA as an effective nanomedicinal system for HCC therapy.
Collapse
Affiliation(s)
- Tinghui Yin
- Department of Medical Ultrasonic, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou 510630, China; PCFM Lab of Ministry of Education, School of Chemistry and Chemical Engineering, Sun Yat-sen University, Guangzhou 510275, China
| | - Ping Wang
- Department of Medical Ultrasonic, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou 510630, China
| | - Jingguo Li
- PCFM Lab of Ministry of Education, School of Chemistry and Chemical Engineering, Sun Yat-sen University, Guangzhou 510275, China
| | - Yiru Wang
- PCFM Lab of Ministry of Education, School of Chemistry and Chemical Engineering, Sun Yat-sen University, Guangzhou 510275, China
| | - Bowen Zheng
- Department of Medical Ultrasonic, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou 510630, China
| | - Rongqin Zheng
- Department of Medical Ultrasonic, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou 510630, China.
| | - Du Cheng
- PCFM Lab of Ministry of Education, School of Chemistry and Chemical Engineering, Sun Yat-sen University, Guangzhou 510275, China
| | - Xintao Shuai
- PCFM Lab of Ministry of Education, School of Chemistry and Chemical Engineering, Sun Yat-sen University, Guangzhou 510275, China; Center of Biomedical Engineering, Zhongshan School of Medicine, Sun Yat-sen University, Guangzhou 510275, China.
| |
Collapse
|
80
|
Chen H, Zhou X, Gao Y, Zheng B, Tang F, Huang J. Recent progress in development of new sonosensitizers for sonodynamic cancer therapy. Drug Discov Today 2014; 19:502-9. [DOI: 10.1016/j.drudis.2014.01.010] [Citation(s) in RCA: 219] [Impact Index Per Article: 19.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2013] [Revised: 01/13/2014] [Accepted: 01/22/2014] [Indexed: 12/20/2022]
|
81
|
Graham SM, Carlisle R, Choi JJ, Stevenson M, Shah AR, Myers RS, Fisher K, Peregrino MB, Seymour L, Coussios CC. Inertial cavitation to non-invasively trigger and monitor intratumoral release of drug from intravenously delivered liposomes. J Control Release 2014; 178:101-7. [PMID: 24368302 DOI: 10.1016/j.jconrel.2013.12.016] [Citation(s) in RCA: 50] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2013] [Revised: 12/06/2013] [Accepted: 12/16/2013] [Indexed: 12/18/2022]
Abstract
The encapsulation of cytotoxic drugs within liposomes enhances pharmacokinetics and allows passive accumulation within tumors. However, liposomes designed to achieve good stability during the delivery phase often have compromised activity at the target site. This problem of inefficient and unpredictable drug release is compounded by the present lack of low-cost, non-invasive methods to measure such release. Here we show that focused ultrasound, used at pressures similar to those applied during diagnostic ultrasound scanning, can be utilised to both trigger and monitor release of payload from liposomes. Notably, drug release was influenced by liposome composition and the presence of SonoVue® microbubbles, which provided the nuclei for the initiation of an event known as inertial cavitation. In vitro studies demonstrated that liposomes formulated with a high proportion of 1,2 distearoyl-sn-glycero-3-phosphoethanolamine (DSPE) released up to 30% of payload following ultrasound exposure in the presence of SonoVue®, provided that the exposure created sufficient inertial cavitation events, as characterised by violent bubble collapse and the generation of broadband acoustic emissions. In contrast a 'Doxil'-like liposome formulation gave no such triggered release. In pre-clinical studies, ultrasound was used as a non-invasive, targeted stimulus to trigger a 16-fold increase in the level of payload release within tumors following intravenous delivery. The inertial cavitation events driving this release could be measured remotely in real-time and were a reliable predictor of drug release.
Collapse
Affiliation(s)
- Susan M Graham
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Old Road Campus Research Building, Oxford, OX3 7DQ, UK
| | - Robert Carlisle
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Old Road Campus Research Building, Oxford, OX3 7DQ, UK.
| | - James J Choi
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Old Road Campus Research Building, Oxford, OX3 7DQ, UK
| | - Mark Stevenson
- Department of Oncology, University of Oxford, Old Road Campus Research Building, Oxford, OX3 7DQ, UK
| | - Apurva R Shah
- Department of Oncology, University of Oxford, Old Road Campus Research Building, Oxford, OX3 7DQ, UK
| | - Rachel S Myers
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Old Road Campus Research Building, Oxford, OX3 7DQ, UK
| | - Kerry Fisher
- Department of Oncology, University of Oxford, Old Road Campus Research Building, Oxford, OX3 7DQ, UK
| | - Miriam-Bazan Peregrino
- Institut d'Investigacio Biomedica de Bellvitge, Gran Via 199, L'Hospitalet de Llobregat, 08908 Barcelona, Spain
| | - Len Seymour
- Department of Oncology, University of Oxford, Old Road Campus Research Building, Oxford, OX3 7DQ, UK
| | - Constantin C Coussios
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Old Road Campus Research Building, Oxford, OX3 7DQ, UK
| |
Collapse
|
82
|
|
83
|
Carlisle R, Choi J, Bazan-Peregrino M, Laga R, Subr V, Kostka L, Ulbrich K, Coussios CC, Seymour LW. Enhanced tumor uptake and penetration of virotherapy using polymer stealthing and focused ultrasound. J Natl Cancer Inst 2013; 105:1701-10. [PMID: 24168971 PMCID: PMC3833932 DOI: 10.1093/jnci/djt305] [Citation(s) in RCA: 90] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
Background Oncolytic viruses are among the most powerful and selective cancer therapeutics under development and are showing robust activity in clinical trials, particularly when administered directly into tumor nodules. However, their intravenous administration to treat metastatic disease has been stymied by unfavorable pharmacokinetics and inefficient accumulation in and penetration through tumors. Methods Adenovirus (Ad) was “stealthed” with a new N-(2-hydroxypropyl)methacrylamide polymer, and circulation kinetics were characterized in Balb/C SCID mice (n = 8 per group) bearing human ZR-75-1 xenograft tumors. Then, to noninvasively increase extravasation of the circulating polymer-coated Ad into the tumor, it was coinjected with gas microbubbles and the tumor was exposed to 0.5 MHz focused ultrasound at peak rarefactional pressure of 1.2MPa. These ultrasound exposure conditions were designed to trigger inertial cavitation, an acoustic phenomenon that produces shock waves and can be remotely monitored in real-time. Groups were compared with Student t test or one-way analysis of variance with Tukey correction where groups were greater than two. All statistical tests were two-sided. Results Polymer-coating of Ad reduced hepatic sequestration, infection (>8000-fold; P < .001), and toxicity and improved circulation half-life (>50-fold; P = .001). Combination of polymer-coated Ad, gas bubbles, and focused ultrasound enhanced tumor infection >30-fold; (4×106 photons/sec/cm2; standard deviation = 3×106 with ultrasound vs 1.3×105; standard deviation = 1×105 without ultrasound; P = .03) and penetration, enabling kill of cells more than 100 microns from the nearest blood vessel. This led to substantial and statistically significant retardation of tumor growth and increased survival. Conclusions Combining drug stealthing and ultrasound-induced cavitation may ultimately enhance the efficacy of a range of powerful therapeutics, thereby improving the treatment of metastatic cancer.
Collapse
Affiliation(s)
- Robert Carlisle
- Affiliations of authors: Institute of Biomedical Engineering, Department of Engineering Science(RC, JC, C-CC) and Department of Oncology (RL, LWS), University of Oxford, Oxford, UK; Institut d'Investigacio Biomedica de Bellvitge, L'Hospitalet de Llobregat, Barcelona, Spain (MB-P); Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic, Prague, Czech Republic (VS, LK, KU)
| | | | | | | | | | | | | | | | | |
Collapse
|
84
|
Ariga K, Kawakami K, Hill JP. Emerging pressure-release materials for drug delivery. Expert Opin Drug Deliv 2013; 10:1465-9. [DOI: 10.1517/17425247.2013.819340] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|