51
|
Vargas V, Alió JL, Alió Del Barrio JL, Cantó-Cerdán M, Barraquer RI, Duch F, Marinho A. Bilensectomy: Safety and Visual Outcomes in Angle-Supported, Iris-Fixated, and Posterior Chamber Phakic Intraocular Lenses. J Refract Surg 2023; 39:128-134. [PMID: 36779470 DOI: 10.3928/1081597x-20221130-01] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/14/2023]
Abstract
PURPOSE To report the visual and refractive outcomes, intraoperative and postoperative complications, and main causes of bilensectomy in the different types of phakic intraocular lenses (pIOLs). METHODS This was a retrospective multicenter study that included 234 eyes of 185 patients that underwent bilensectomy. Patients were divided into three groups depending on the pIOL that was explanted (angle-supported, iris-fixated, or posterior chamber). The main reasons leading to the indication for bilensectomy, time elapsed between pIOL implantation and bilensectomy, intraoperative and postoperative complications, uncorrected and corrected distance visual acuity (UDVA and CDVA), and endothelial cell density loss 1 year after bilensectomy were evaluated. RESULTS There was a statistically significant improvement in UDVA and CDVA after bilensectomy in all groups. Cataract development was the main reason for bilensectomy, followed by significant endothelial cell density loss. Time between pIOL implantation and bilensectomy was significantly greater in eyes with an anterior chamber pIOL. CONCLUSIONS Bilensectomy outcomes in general are good. Iris-fixated lenses, particularly hyperopic, are more prone to intraoperative complications and endothelial cell loss than the other pIOLs models. The results show that bilensectomy is a safe and effective procedure with a relatively low rate of intraoperative and postoperative complications and acceptable refractive predictability. [J Refract Surg. 2023;39(3):128-134.].
Collapse
|
52
|
Rocamora L, Orlando JI, Lwowski C, Kohnen T, Mertens E, Van Keer K. Postoperative vault prediction for phakic implantable collamer lens surgery: LASSO formulas. J Cataract Refract Surg 2023; 49:126-132. [PMID: 36255226 PMCID: PMC9872858 DOI: 10.1097/j.jcrs.0000000000001079] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Accepted: 10/10/2022] [Indexed: 01/27/2023]
Abstract
PURPOSE To develop and evaluate reliable formulas for predicting postoperative vault more accurately after implantable collamer lens (ICL) surgery in a White patient population with varying degrees of ametropia. SETTING Private clinical practice. DESIGN Retrospective analysis on dataset split into a separate training and test set. METHODS 115 eyes of 59 patients were used to train regression models predicting postoperative vault based on anterior segment optical coherence tomography (OCT) parameters (Least Absolute Shrinkage and Selection Operator [LASSO]-OCT formula), ocular biometry data (LASSO-Biometry formula), or data from both devices (LASSO-Full formula). The performance of these models was evaluated against the manufacturer's nomogram (Online Calculation and Ordering System [OCOS]) and Nakamura 1 (NK1) and 2 (NK2) formulas on a matched separate test set of 37 eyes of 19 patients. RESULTS The mean preoperative spherical equivalent was -5.32 ± 3.37 (range: +3.75 to -17.375 diopters). The mean absolute errors of the estimated vs achieved postoperative vault for the LASSO-Biometry, LASSO-OCT, and LASSO-Full formulas were 144.1 ± 107.9 μm, 145.6 ± 100.6 μm, and 132.0 ± 86.6 μm, respectively. These results were significantly lower compared with the OCOS, NK1, and NK2 formulas ( P < .006). Postoperative vault could be estimated within 500 μm in 97.3% (LASSO-Biometry) to 100% of cases (LASSO-OCT and LASSO-Full). CONCLUSIONS The LASSO suite provided a set of powerful, reproducible yet convenient ICL sizing formulas with state-of-the-art performance in White patients, including those with low to moderate degrees of myopia. The calculator can be accessed at http://icl.emmetropia.be .
Collapse
|
53
|
Martínez-Plaza E, López-de la Rosa A, López-Miguel A, Holgueras A, Maldonado MJ. EVO/EVO+ Visian Implantable Collamer Lenses for the correction of myopia and myopia with astigmatism. Expert Rev Med Devices 2023; 20:75-83. [PMID: 36708714 DOI: 10.1080/17434440.2023.2174429] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
INTRODUCTION Intraocular lens implantation in phakic eyes for the correction of refractive error is currently a widespread procedure. The EVO and EVO+ Visian Implantable Collamer Lenses (ICL) are two of the most prevalent lenses implanted. They incorporate a central orifice to avoid the need for iridotomy. The main difference between both ICL is the higher optical diameter zone provided by the EVO+, allowing a better quality of vision at night. This review aims to provide an overview of the current ICL models available for correcting myopia and myopic astigmatism. AREAS COVERED During the last decade, more than 100 scientific papers analyzing the performance of EVO and EVO+ lenses have been published. This review describes the objective visual performance achieved with the implantation of central hole ICL lenses and the subjective perception of the patients implanted with these lenses. In addition, the safety and the potential complications associated with undergoing an EVO and EVO+ ICL implantation have been addressed. EXPERT OPINION Refractive surgeons and candidates to undergo ICL implantation should be aware of the excellent safety and visual outcomes provided by the implantation of central hole ICL lenses. However, future research could address minor issues currently not resolved.
Collapse
Affiliation(s)
- Elena Martínez-Plaza
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Valladolid, Spain
| | | | - Alberto López-Miguel
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Valladolid, Spain
| | - Alfredo Holgueras
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Valladolid, Spain
| | - Miguel J Maldonado
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Valladolid, Spain
| |
Collapse
|
54
|
Choi H, Kim T, Kim SJ, Sa BG, Ryu IH, Lee IS, Kim JK, Han E, Kim HK, Yoo TK. Predicting Postoperative Anterior Chamber Angle for Phakic Intraocular Lens Implantation Using Preoperative Anterior Segment Metrics. Transl Vis Sci Technol 2023; 12:10. [PMID: 36607625 PMCID: PMC9836008 DOI: 10.1167/tvst.12.1.10] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Abstract
Purpose The anterior chamber angle (ACA) is a critical factor in posterior chamber phakic intraocular lens (EVO Implantable Collamer Lens [ICL]) implantation. Herein, we predicted postoperative ACAs to select the optimal ICL size to reduce narrow ACA-related complications. Methods Regression models were constructed using pre-operative anterior segment optical coherence tomography metrics to predict postoperative ACAs, including trabecular-iris angles (TIAs) and scleral-spur angles (SSAs) at 500 µm and 750 µm from the scleral spur (TIA500, TIA750, SSA500, and SSA750). Data from three expert surgeons were assigned to the development (N = 430 eyes) and internal validation (N = 108 eyes) datasets. Additionally, data from a novice surgeon (N = 42 eyes) were used for external validation. Results Postoperative ACAs were highly predictable using the machine-learning (ML) technique (extreme gradient boosting regression [XGBoost]), with mean absolute errors (MAEs) of 4.42 degrees, 3.77 degrees, 5.25 degrees, and 4.30 degrees for TIA500, TIA750, SSA500, and SSA750, respectively, in internal validation. External validation also showed MAEs of 3.93 degrees, 3.86 degrees, 5.02 degrees, and 4.74 degrees for TIA500, TIA750, SSA500, and SSA750, respectively. Linear regression using the pre-operative anterior chamber depth, anterior chamber width, crystalline lens rise, TIA, and ICL size also exhibited good performance, with no significant difference compared with XGBoost in the validation sets. Conclusions We developed linear regression and ML models to predict postoperative ACAs for ICL surgery anterior segment metrics. These will prevent surgeons from overlooking the risks associated with the narrowing of the ACA. Translational Relevance Using the proposed algorithms, surgeons can consider the postoperative ACAs to increase surgical accuracy and safety.
Collapse
Affiliation(s)
- Hannuy Choi
- Department of Refractive Surgery, B&VIIT Eye Center, Seoul, South Korea
| | - Taein Kim
- Research and Development Department, VISUWORKS, Seoul, South Korea
| | - Su Jeong Kim
- Research and Development Department, VISUWORKS, Seoul, South Korea
| | - Beom Gi Sa
- Research and Development Department, VISUWORKS, Seoul, South Korea
| | - Ik Hee Ryu
- Department of Refractive Surgery, B&VIIT Eye Center, Seoul, South Korea,Research and Development Department, VISUWORKS, Seoul, South Korea
| | - In Sik Lee
- Department of Refractive Surgery, B&VIIT Eye Center, Seoul, South Korea
| | - Jin Kuk Kim
- Department of Refractive Surgery, B&VIIT Eye Center, Seoul, South Korea
| | - Eoksoo Han
- Electronics and Telecommunications Research Institute (ETRI), Daejeon, South Korea
| | - Hong Kyu Kim
- Department of Ophthalmology, Dankook University Hospital, Dankook University College of Medicine, Cheonan, South Korea
| | - Tae Keun Yoo
- Department of Refractive Surgery, B&VIIT Eye Center, Seoul, South Korea,Research and Development Department, VISUWORKS, Seoul, South Korea
| |
Collapse
|
55
|
Qian T, Du J, Ren R, Zhou H, Li H, Zhang Z, Xu X. Vault-Correlated Efficacy and Safety of Implantable Collamer Lens V4c Implantation for Myopia in Patients with Shallow Anterior Chamber Depth. Ophthalmic Res 2023; 66:445-456. [PMID: 36596292 DOI: 10.1159/000528616] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2022] [Accepted: 11/27/2022] [Indexed: 01/04/2023]
Abstract
INTRODUCTION The aim of the study was to evaluate efficacy and safety outcomes after implantation of the Visian Implantable Collamer Lens (ICL V4c) in myopia patients with shallow anterior chamber depth (ACD). METHODS This retrospective study followed 163 eyes of 94 patients for at least 24 months. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity, intraocular pressure (IOP), manifest refraction, vault, endothelial cell density (ECD), anterior chamber angle (ACA), anterior chamber volume, and the distance from the corneal endothelium to the central ICL (C-ICL) were measured during follow-ups. Spearman's correlation and logistic regression were used to identify variables correlated with changes in ECD and potential risk factors for ineffective outcomes, respectively. RESULTS All surgeries were performed safely. High IOP of 9 eyes and anterior capsular opacity of 5 eyes were observed. The last follow-up ACA had a significant difference between the high and normal IOP groups (p = 0.0003). The mean ECD and vault were 2,855.76 ± 270.82 cells/mm2 and 388.01 ± 135.28 μm at the last follow-up, respectively. The vault and C-ICL were significantly associated with ΔECD (all p < 0.05). Furthermore, the vault was most responsible for the ECD loss. Twenty-two eyes had unsatisfactory postoperative UDVA, and the low vault at the last follow-up was a significant risk factor for this ineffective outcome (p < 0.001, OR = 14.739). CONCLUSIONS ICL V4c implantation in patients with shallow ACD achieved stable visual outcomes. The vault is related to postoperative visual acuity and ECD loss, which needs to be paid attention during follow-up.
Collapse
Affiliation(s)
- Tianwei Qian
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai, China
- National Clinical Research Center for Eye Diseases, Shanghai, China
- Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai, China
- Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai, China
- Shanghai Engineering Center for Precise Diagnosis and Treatment of Eye Disease, Shanghai, China
| | - Jingxiao Du
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai, China
- National Clinical Research Center for Eye Diseases, Shanghai, China
- Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai, China
- Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai, China
- Shanghai Engineering Center for Precise Diagnosis and Treatment of Eye Disease, Shanghai, China
| | - Ruixia Ren
- Shanghai Xinshijie Zhongxing Eye Hospital, Shanghai, China
| | - Hao Zhou
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai, China
- National Clinical Research Center for Eye Diseases, Shanghai, China
- Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai, China
- Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai, China
- Shanghai Engineering Center for Precise Diagnosis and Treatment of Eye Disease, Shanghai, China
| | - Haiyan Li
- Shanghai Xinshijie Zhongxing Eye Hospital, Shanghai, China
| | - Zhihua Zhang
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai, China
- National Clinical Research Center for Eye Diseases, Shanghai, China
- Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai, China
- Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai, China
- Shanghai Engineering Center for Precise Diagnosis and Treatment of Eye Disease, Shanghai, China
| | - Xun Xu
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai, China
- National Clinical Research Center for Eye Diseases, Shanghai, China
- Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai, China
- Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai, China
- Shanghai Engineering Center for Precise Diagnosis and Treatment of Eye Disease, Shanghai, China
| |
Collapse
|
56
|
Wang Q, Fan L, Zhou Q. The best choice for low and moderate myopia patients incapable for corneal refractive surgery: implantation of a posterior chamber phakic intraocular lens. Int Ophthalmol 2023; 43:575-581. [PMID: 35984557 PMCID: PMC9971141 DOI: 10.1007/s10792-022-02459-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2021] [Accepted: 07/31/2022] [Indexed: 11/28/2022]
Abstract
PURPOSE This study aims to evaluate the early clinical outcomes of central hole phakic posterior chamber intraocular lens(ICLV4c) implantation for low and moderate myopia correction. METHODS This retrospective clinical study included 27 patients(47 eyes)who underwent ICLV4c implantation to correct myopia with spherical equivalent (SE) between - 1.75D and -6.0D. The uncorrected visual acuity (UCVA), intraocular pressure(IOP), central anterior chamber depth (ACD), vault, and endothelial cell density (ECD) were evaluated after surgery. RESULTS At one year follow-up, the postoperative UCVA of patients was higher than the preoperative CDVA and showed a stable trend. There was no significant difference in ECD (p > 0.05) one month after the surgery, the vault was 0.77 ± 0.32 mm, which decreased to 0.63 ± 0.26 mm after one year of surgery. Similarly, ACD was 3.24 ± 0.25 mm in the preoperative, which decreased significantly to 2.05 ± 0.39 mm at one month, while rose to 2.2 ± 0.39 mm at one year after surgery. There was no significant correlation between IOP and ACD and vault at one month and one year after surgery. The correlation coefficient between ACD and vault was found to be - 0.72 at one month after surgery, while the same -0.71 after one year. One patient developed visual fatigue, one with glare, and while no other complications were observed with the rest of the patients. CONCLUSION The ICL implantation is a safe, effective and stable method to correct low and moderate myopia, and may be a good alternative for patients with low and moderate myopia who cannot undergo corneal refractive surgery.
Collapse
Affiliation(s)
- Qin Wang
- Chongqing Aier Eye Hospital, Chongqing, 400020 China
| | - Lina Fan
- Chongqing Aier Eye Hospital, Chongqing, 400020 China
| | - Qizhi Zhou
- Aier Chongqing Optometry Eye hospital, No. 77, Daping Changjiang Second Road, Yuzhong, Chongqing, 400040, China.
| |
Collapse
|
57
|
Jiang Y, Luo Y, Li Y, Lu T. The long-term observation of the rotation of implantable collamer lens as the management of high postoperative vault. Front Med (Lausanne) 2023; 10:1104047. [PMID: 36910497 PMCID: PMC9995363 DOI: 10.3389/fmed.2023.1104047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Accepted: 02/02/2023] [Indexed: 02/25/2023] Open
Abstract
Purpose This study aimed to describe the effectiveness and stability of implantable collamer lens (ICL) rotation in reducing high postoperative vault. Setting This study was conducted in the Peking Union Medical College Hospital, Chinese Academy of Medical Sciences. Design This is a retrospective case series. Methods Twenty-two eyes from 22 patients who had ICL (V4c EVO) implantation with high postoperative vault (>=750 μm) were recruited for our study. All the lenses were rotated from a horizontal to an oblique position. The vault, SSA, AOD500, AOD750, TISA500, and TISA750 at 180° and 0° were measured pre-rotation, 1-week post-rotation, and in the at-least 1-year-follow-up. Results Twenty female patients and two male patients were recruited, with a mean age of 28.68 ± 6.08 years. The mean vault had declined significantly from 951.81 ± 154.26 μm pre-rotation to 772.27 ± 119.40 μm 1 week post-rotation (p < 0.001). The SSA, AOD500, AOD750, TISA500, and TISA750 at 180° and 0° pre-rotation and 1-week post-rotation were 30.40 ± 7.91° and 45.14 ± 6.75°, 32.37 ± 7.48° and 46.23 ± 6.39°, 303.27 ± 87.99 and 522.45 ± 122.16 μm, 323.81 ± 89.15 and 536.13 ± 121.66 μm, 387.95 ± 99.43 and 630.81 ± 133.59 μm, 435.68 ± 106.72 and 643.36 ± 132.82 μm, 0.109 ± 0.034 and 0.202 ± 0.053 mm2, 0.123 ± 0.034 and 0.212 ± 0.051 mm2, 0.194 ± 0.056 and 0.345 ± 0.083 mm2, and 0.216 ± 0.055 and 0.358 ± 0.079 mm2 (all p < 0.001). The mean vault value had changed from 747.50 ± 116.07 μm 1-week post-rotation to 586.87 ± 132.65 μm in the 1-year follow-up. However, the SSA, AOD500, AOD750, TISA500, and TISA750 at 180° and 0° had remained stable (p > 0.05). Conclusion Non-toric ICL rotation is a novel and effective technique in the treatment of high postoperative vault. Our results are more robust given the extended period of follow-up.
Collapse
Affiliation(s)
- Yang Jiang
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, China
| | - Yan Luo
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, China
| | - Ying Li
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, China
| | - Thomas Lu
- School of Medicine, University of New South Wales, Kensington, NSW, Australia
| |
Collapse
|
58
|
Wu H, Zhong DJ, Luo DQ, Zhang LY, Liu J, Wang H. Improvement in the ideal range of vault after implantable collamer lens implantation: a new vault prediction formula. Front Med (Lausanne) 2023; 10:1132102. [PMID: 37181381 PMCID: PMC10174235 DOI: 10.3389/fmed.2023.1132102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2022] [Accepted: 04/06/2023] [Indexed: 05/16/2023] Open
Abstract
Background To derive and validate a novel vault prediction formula to improve the predictability and safety of implantable collamer lens (ICL) implantation. Methods Thirty-five patients (61 eyes) with previous posterior chamber intraocular lens implantation were included. Various parameters, such as horizontal-visible iris diameter (HVID), photopic pupil diameter (PPD), axial length (AL), white-to-white (WTW), anterior chamber width (ACW), angle-to-angle (ATA), crystalline lens rise (CLR), anterior chamber depth (ACD), horizontal sulcus-to-sulcus (HSTS), and ciliary sulcus angle (CSA) were measured. Vault was measured at 3 months after surgery using CASIA2 anterior segment optical coherence tomography. The formula was derived using multiple linear regression analysis and named as WH formula. It was validated in 65 patients (118 eyes) to determine the percentage of the ideal postoperative vault range and to compare the differences between the WH formula and the NK, KS, and STAAR formulas. Results Final ICL size, ATA, CSA, and CLR were included in the prediction formula model (adjusted R2 = 0.67, p < 0.001). The achieved vault 1 month after the surgery was 556.19 μm ± 166.98 μm in the validation group, and the ideal vault range was 200-800 μm (92%). The difference between the achieved vault and that predicted using the WH formula was not statistically significant (p = 0.165), whereas the difference between the achieved vault and that predicted using the NK and KS formulas was statistically significant (p < 0.001 and p < 0.001, respectively). The 95% agreement limit range of the achieved vault and the vault predicted using the WH formula was narrower than those predicted using the NK and KS formulas (-295.20-258.82 μm). Conclusion This study combined the results of optical coherence tomography and ultrasound biomicroscopy measurements of the anterior segment of the eye and incorporated ciliary sulcus morphology quantification into the prediction formula. The study derived a prediction formula for vault by combining ICL size, ATA, and CLR. The derived formula was found to be superior to the currently available formulas.
Collapse
|
59
|
Amer AA, Ahmed Ghanem Abu El Wafa Ali E, Sayed Ahmed E, Ateto Hamed M, el Shazly Eata W, Amer I. Posterior-Chamber Phakic Implantable Collamer Lenses with and without a Central Hole: A Comparative Study. Clin Ophthalmol 2023; 17:887-895. [PMID: 36942086 PMCID: PMC10023812 DOI: 10.2147/opth.s405689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Accepted: 03/13/2023] [Indexed: 03/18/2023] Open
Abstract
Purpose This study aimed to compare the short-term outcome of implanting the Visian implantable collamer lens V4 ICL versus the Visian V4c ICL in patients with moderate and high myopia. Patients and Methods This is a retrospective that was conducted on patients with moderate or high myopia who were scheduled for ICL implantation at our institution, Patients who underwent V4 ICL implantation with peripheral iridectomy were assigned to group A, and those who underwent V4c ICL implantation without peripheral iridectomy were assigned to group B. In group A, a preoperative peripheral iridectomy was performed. In group B, the patients received cycloplegic and dilating agents. The patients underwent a complete ocular examination preoperatively and during the follow-up visits that were conducted at 3, 6, and 12 months postoperatively. Results This study included 214 eyes from 107 patients; group A included 110 eyes, and group B included 104 eyes. Postoperatively, the UCVA and BCVA showed statistically significant improvement across the follow-up time points (p<0.001), with no significant difference between the two groups. No statistically significant difference was found between the two groups in the mean achieved correction or the residual refraction. Both groups showed a strong correlation between the target and the achieved correction, with R2 = 0.99 in the two groups. No significant difference was found between the two groups in the IOP across all time measures. However, the intraocular pressure showed a statistically significant postoperative increase in group A (p=0.004), and no significant change in group B (p=0.817). There was a downward slope in the vaults of both groups across time, with significant variation in the last follow-up measure compared to the 3-month measure in the two groups (p<0.001). No significant difference was found between the two groups across all time measures. Conclusion The current study adds new evidence concerning the feasibility, safety, and efficacy of ICL V4c implantation for the treatment of moderate and high myopia, with safer postoperative IOP.
Collapse
Affiliation(s)
- Ahmed Ali Amer
- Ophthalmology Department, Qena Faculty of Medicine, South Valley University, Qena, Egypt
- Correspondence: Ahmed Ali Amer, Tel +20 101 182 7000, Email
| | | | | | | | - Wael el Shazly Eata
- Ophthalmology Department, Qena Faculty of Medicine, South Valley University, Qena, Egypt
| | - Ibrahim Amer
- Ophthalmology Department, Al Azhar University, Assuit, Egypt
| |
Collapse
|
60
|
Wannapanich T, Kasetsuwan N, Reinprayoon U. Intraocular Implantable Collamer Lens with a Central Hole Implantation: Safety, Efficacy, and Patient Outcomes. Clin Ophthalmol 2023; 17:969-980. [PMID: 36998514 PMCID: PMC10046236 DOI: 10.2147/opth.s379856] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Accepted: 03/15/2023] [Indexed: 04/01/2023] Open
Abstract
This review summarizes the available literature and provides updates on the efficacy, safety, and patient outcomes of phakic intraocular lens implantation using implantable collamer lens (ICL), with a focus on newer models with a central port (EVO/EVO+ Visian Implantable Collamer Lens, STAAR Surgical Inc.). All studies included in this review were identified from the PubMed database and were reviewed for relevancy of their topic. Data on hole-ICL implantation performed between October 2018 and October 2022 in 3399 eyes showed a weighted average efficacy index of 1.03 and a weighted average safety index of 1.19 within an average follow-up of 24.7 months. The incidence of complications such as elevated intraocular pressure, cataract, and corneal endothelial cell loss was low. Moreover, both quality of vision and quality of life improved after ICL implantation, confirming the benefits of this procedure. In conclusion, ICL implantation is a promising refractive surgery alternative to laser vision correction with excellent efficacy, safety, and patient outcomes.
Collapse
Affiliation(s)
- Trakanta Wannapanich
- Department of Ophthalmology, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Bangkok, Thailand
| | - Ngamjit Kasetsuwan
- Department of Ophthalmology, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Bangkok, Thailand
- Chula Refractive Surgery Center, King Chulalongkorn Memorial Hospital, Bangkok, Thailand
- Excellence Center for Cornea and Limbal Stem Cell Transplantation, Department of Ophthalmology, King Chulalongkorn Memorial Hospital, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
- Correspondence: Ngamjit Kasetsuwan, Department of Ophthalmology, Faculty of Medicine, Chulalongkorn University, 1873 Rama 4 Road, Pathumwan, Bangkok, 10330, Thailand, Tel +6622564142, Email
| | - Usanee Reinprayoon
- Department of Ophthalmology, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Bangkok, Thailand
- Chula Refractive Surgery Center, King Chulalongkorn Memorial Hospital, Bangkok, Thailand
- Excellence Center for Cornea and Limbal Stem Cell Transplantation, Department of Ophthalmology, King Chulalongkorn Memorial Hospital, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
| |
Collapse
|
61
|
Saliev I, Yusupov A, Mukhamedova N. A Case of a Low Vault after Posterior Chamber Acrylic Phakic Intraocular Lens Implantation. Case Rep Ophthalmol 2023; 14:165-172. [PMID: 37065729 PMCID: PMC10091233 DOI: 10.1159/000530008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Accepted: 02/24/2023] [Indexed: 04/18/2023] Open
Abstract
When implanting a posterior chamber phakic intraocular lens (pIOL), it is crucial to maintain a safe distance. The patient was a 29-year-old man with high-degree bilateral myopia. In February 2021, posterior chamber acrylic pIOLs (Eyecryl Phakic TORIC; Biotech Vision Care, Gujarat, India) were implanted in both his eyes. After the surgery, the right eye vault was 6 μm, and the left eye vault was 350 μm. Moreover, the internal anterior chamber depth values were 2,270 and 2,220 μm for the right and left eyes, respectively. In our case, we found a fairly high crystalline lens rise (CLR) in both eyes, but it was greater in the right eye. The CLR value was +455 in the right eye and +350 in the left eye. In our patient, anterior segment anatomical parameters were higher in the right eye than in the left eye, and a greater pIOL length was calculated for the right eye, but the vault was very low. In our opinion, this was associated with the high CLR in the right eye. If an even larger pIOL had been implanted, there would have been a greater narrowing of the anterior chamber angle. This case would be contraindicated if those parameters were considered in selecting the indications and determination of the pIOL length.
Collapse
Affiliation(s)
- Ikbol Saliev
- SAIF-OPTIMA Eye Microsurgery Clinic, Tashkent, Uzbekistan
| | - Azamat Yusupov
- Republican Specialized Scientific and Practical Medical Center for Eye Microsurgery, Тashkent, Uzbekistan
| | | |
Collapse
|
62
|
Zaldivar R, Zaldivar R, Gordillo CH, Adamek P. Visual Acuity Improvement in Low, Moderate and High Myopia After Posterior-Chamber Phakic Implantable Collamer Lens Surgery in a Large Patient Cohort. Clin Ophthalmol 2023; 17:1179-1185. [PMID: 37096208 PMCID: PMC10122501 DOI: 10.2147/opth.s407492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Accepted: 04/11/2023] [Indexed: 04/26/2023] Open
Abstract
Purpose To compare best-corrected visual acuity (BCVA) before and after implantable collamer lens (ICL) surgery in patients with low, moderate and high myopia. Methods A single-centre, prospective, registry-based study involving patients with myopia who received ICLs between October 2018 and August 2020. The study population was divided into three groups of subjects with low (from 0 to -6 D), moderate (-6 to -10 D) and high myopia (more than -10 D). We analysed uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), spherical equivalent (SE), differences between BCVA pre- and 1-month postoperative, and line gain in BCVA 1 month after surgery. Results A total of 770 eyes belonging to 473 patients were surgically intervened during the study period, of which 692 eyes completed 1 month of postoperative follow-up and were included in the study population. At 1-month follow-up, 478 eyes (69%) achieved a BCVA of 20/20, 599 (87%) obtained 20/25 or better, and 663 (96%) had a BCVA of 20/40 or better. We identified a significant improvement in BCVA (baseline 0.15±0.2 logMAR vs follow-up 0.07±0.2 logMAR, p<0.0001) and a significant reduction in SE (baseline -9.23±4.1 D, vs follow-up -0.21±0.8 D, p<0.0001), with a significant relationship between preoperative SE and line gain (r = -0.46, p<0.0001). We identified a significantly higher line gain among eyes with higher degrees of myopia (low myopia 0.22±0.69 lines compared to moderate myopia 0.56±1.1 lines and high myopia 1.51±1.9 lines, p<0.0001). Notably, 99.6% of eyes with a high grade of myopia achieved improvement to a low degree (less than -6 D) at follow-up. The safety and efficacy indexes were 0.083±0.1 and -0.001±0.1, respectively. Conclusion In this large patient cohort, ICL surgery was related to a significant line gain in BCVA, particularly among eyes with higher degrees of myopia.
Collapse
Affiliation(s)
- Roger Zaldivar
- Surgery Department, Instituto Zaldivar, Mendoza, Argentina
- Correspondence: Roger Zaldivar, Instituto Zaldivar, Av. Emilio Civit 701, Mendoza, Argentina, Email
| | | | | | - Pablo Adamek
- Surgery Department, Instituto Zaldivar, Mendoza, Argentina
| |
Collapse
|
63
|
Feldhaus L, Mayer WJ, Dirisamer M, Kassumeh S, Shajari M, Priglinger SG, Luft N. Comparison of Visual and Refractive Outcome between Two Methods of Corneal Marking for Toric Implantable Collamer Lenses (TICL) in Phakic Eyes. Curr Eye Res 2022; 48:357-364. [PMID: 36524538 DOI: 10.1080/02713683.2022.2159981] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
PURPOSE To compare the efficacy of digital-assisted reference marking for toric implantable collamer lenses (Callisto Eye System) with manual marking technique using a slit lamp markeur. METHODS This study included patients that underwent implantation of a toric implantable collamer lens (EVO Visian toric ICL, Staar Surgical). Patients were included if they had a myopia above -3 diopters (D) and regular corneal astigmatism of 0.75 diopters or higher. Between both groups a 1:2 matching regarding similar preoperative level of myopia and astigmatism was performed. Visual and refractive outcomes were evaluated. Vector analysis was performed to evaluate total astigmatic changes. RESULTS This study comprised 57 eyes of 57 patients with 19 eyes in the digital group and 38 eyes in the manual marking group. Postoperatively there were no statistically significant differences between both groups in UDVA (p = 0.467), spherical equivalent (SE) (p = 0.864), sphere (p = 0.761) and cylinder (p = 0.878). Vector analysis showed a slightly more accurate postoperative refractive astigmatism in the manual group (0.26 D at 107° ± 0.50 D) compared to the digital marking group (0.31 D at 107° ± 0.45 D), nevertheless with no statistically significant differences between both groups. CONCLUSIONS A digital tracking approach for toric ICL alignment was an efficient and safe method for toric marking with similar results regarding visual and refractive outcomes compared to a conventional corneal marking method. Nevertheless, image-guided surgery helped to streamline the workflow in refractive ICL surgery.
Collapse
Affiliation(s)
- Lukas Feldhaus
- Department of Ophthalmology, University Hospital, LMU Munich, Munich, Germany
| | - Wolfgang J Mayer
- Department of Ophthalmology, University Hospital, LMU Munich, Munich, Germany
| | - Martin Dirisamer
- Department of Ophthalmology, University Hospital, LMU Munich, Munich, Germany
| | - Stefan Kassumeh
- Department of Ophthalmology, University Hospital, LMU Munich, Munich, Germany
| | - Mehdi Shajari
- Department of Ophthalmology, University Hospital, LMU Munich, Munich, Germany
| | | | - Nikolaus Luft
- Department of Ophthalmology, University Hospital, LMU Munich, Munich, Germany
| |
Collapse
|
64
|
Zaldivar R, Zaldivar R, Adamek P, Quintero G, Cerviño A. Descriptive Analysis of Footplate Position After Myopic Implantable Collamer Lens Implantation Using a Very High-Frequency Ultrasound Robotic Scanner. Clin Ophthalmol 2022; 16:3993-4001. [PMID: 36504639 PMCID: PMC9733561 DOI: 10.2147/opth.s393223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Accepted: 11/17/2022] [Indexed: 12/07/2022] Open
Abstract
Purpose To assess the position of the haptics of the implantable collamer lens (ICL) in myopic eyes using a high-frequency ultrasound robotic scanner. Methods This was a prospective, single-arm, observational study carried out at the Instituto Zaldivar SA (Mendoza, Argentina) in a sample of 52 eyes who have been submitted to successful ICL implantation prior to enrollment. Images of the eyes were obtained using a very-high frequency digital ultrasound robotic scanner (VHFDU) to establish the position of the ICL in the posterior chamber and its relation to the ciliary sulcus. New parameters for lens position analysis were also described. Results In 81% of cases (42 eyes), the ICL rests on the ciliary body (CB) in both temporal and nasal sides, being slightly lower than 6% (3 eyes) those that rest on the sulcus in both sides, with significant correlations between ICL position and vault values (p<0.05). Cases in which the ICL position was CB-CB yielded central vault values across the whole range determined within the sample, but most of the eyes where the ICL rests on both the sulcus in one side and the CB in the other yield greater central vault values. Correlation was significant between ICL position and retroposition distance on the temporal side (Spearman's rho -0.487, p<0.001). A significant but weaker correlation was also found between ICL position and retroiridian space (p<0.05). Conclusion ICL for myopia footplates tend to locate outside of the sulcus in a significant percentage of patients after successful implantation. VHFDU assessment in eyes implanted with an ICL to properly study the lens footplate position and posterior anatomical relations provides important additional information besides post-surgery vault.
Collapse
Affiliation(s)
| | | | | | | | - Alejandro Cerviño
- Department of Optics & Optometry & Vision Sciences, University of Valencia, Valencia, Spain,Correspondence: Alejandro Cerviño, Department of Optics & Optometry & Vision Science, University of Valencia, C / Dr. Moliner, 50. Burjassot, Valencia, 46100, Spain, Tel +34 963 544 852, Email
| |
Collapse
|
65
|
Zhu QJ, Xing XY, Zhu MH, Ma L, Yuan Y, Song E. Validation of the vault prediction model based on the sulcus-to-sulcus diameter and lens thickness: a 925-eye prospective study. BMC Ophthalmol 2022; 22:463. [PMID: 36451125 PMCID: PMC9714062 DOI: 10.1186/s12886-022-02698-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2022] [Accepted: 11/21/2022] [Indexed: 12/05/2022] Open
Abstract
BACKGROUND To verify the accuracy and stability of the prediction formula based on the ciliary sulcus diameter and lens thickness and to analyse factors influencing the prediction results. METHODS In total, 925 eyes from 506 subjects were enrolled in this prospective study between July 1, 2020, and June 30, 2021. Subjects were divided into four seasons, each spanning three months. The target vault was set to be between 300 μm and 700 μm according the prediction formula. The actual vault was measured one month postoperatively. The Bland-Altman test, 95% confidence intervals (95% CI) and 95% limits of agreement (95% LoA) were used to evaluate the agreement between the predicted vault and the actual vault. Eyes with absolute prediction errors greater than 300 μm were further analysed. RESULTS The mean predicted vaults for the four seasons were 503 ± 99, 494 ± 96, 481 ± 92 and 502 ± 93 μm, while the mean actual vaults were 531 ± 189, 491 ± 179, 464 ± 179 and 529 ± 162 μm, respectively. The predicted and actual vaults of the overall subjects were 493 ± 95 and 500 ± 180 μm, respectively. Of the 925 eyes, 861 eyes (93.08%), 42 eyes (4.54%), and 22 eyes (2.38%) showed a normal vault, high vault, and low vault, respectively. Bland-Altman plots showed that the mean difference between the actual vault and predicted vault overall (± 95% LoA) was 6.43 ± 176.2 μm (-339 to 352 μm). Three UBM features may lead to large prediction errors (more than 300 μm): wide iris-ciliary angle (ICA), iris concavity and anteriorly positioned ciliary body. CONCLUSIONS This study demonstrated the accuracy and stability of the prediction formula through the validation of a large sample size and a long time span. Wide ICA, iris concavity and anteriorly positioned ciliary body may have an effect on vault.
Collapse
Affiliation(s)
- Qiu-Jian Zhu
- grid.452666.50000 0004 1762 8363Department of Ophthalmology, The Second Affiliated Hospital of Soochow University, Suzhou, China ,grid.263761.70000 0001 0198 0694Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Suzhou, China
| | | | - Man-Hui Zhu
- grid.263761.70000 0001 0198 0694Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Suzhou, China
| | - Lie Ma
- grid.263761.70000 0001 0198 0694Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Suzhou, China
| | - You Yuan
- grid.263761.70000 0001 0198 0694Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Suzhou, China
| | - E. Song
- grid.263761.70000 0001 0198 0694Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Suzhou, China
| |
Collapse
|
66
|
Sánchez Trancón A, Cerpa Manito S, Torrado Sierra O, Baptista AM, Serra PM. Vault differences in eyes implanted with spherical and toric implantable collamer lenses: an inter-eye analysis. BMC Ophthalmol 2022; 22:435. [PMCID: PMC9664806 DOI: 10.1186/s12886-022-02653-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Accepted: 10/11/2022] [Indexed: 11/16/2022] Open
Abstract
Abstract
Purpose
To determine the influence of implantable collamer lenses (ICL) geometry, i.e. spherical and toric on the vault, and report the refractive and visual outcomes of patients bilaterally implanted with the two ICL geometries.
Methods
This retrospective case series analysed 41 patients implanted with a spherical ICL (sICL) in one eye and an equal sized toric ICL (tICL) in the fellow eye. The anatomical and ICL-related parameters were assessed using anterior-segment optical coherence tomography (AS-OCT Visante, Zeiss Meditec AG) and optical tomography (Pentacam, OCULUS). The influence of the anatomical and ICL-related parameters on the vault was determined using generalised estimating equations (GEE) to incorporate inter-eye correlations.
Results
Postoperative spherical equivalent was within ± 0.50D in 66% and 83% of the eyes, respectively implanted with sICL and tICL. The efficacy index in the sICL group was 1.06 and 1.14 in the tICL group. The mean inter-eye vault difference was -1.46 µm, anatomical and ICL-related parameters showed similar associations with the vault for sICL and tICL. The GEE identified the ICL size minus the anterior chamber width, the ICL spherical power and ICL central thickness as significant factors influencing the vault.
Conclusions
Spherical and toric ICL showed good efficacy for the correction of myopia and astigmatism. Patients implanted bilaterally with sICL and tICL tend to present similar vaults. The vault produced by both types of ICL was mainly regulated by the oversizing of the ICL. This suggests that the ICL geometry (spherical vs toric) is a factor with limited influence on the vault, thus the sizing method of a sICL and tICL should be similar.
Collapse
|
67
|
García C, Camps VJ, Caballero MT, Piñero DP, Tañá P, Tello C, Miret JJ. Comparison of the optical quality vision between real post-LASIK myopic laser surgery and the simulated implantation of a phakic IOL in low myopia. Sci Rep 2022; 12:18942. [PMID: 36344601 PMCID: PMC9640728 DOI: 10.1038/s41598-022-23662-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Accepted: 11/03/2022] [Indexed: 11/09/2022] Open
Abstract
A phakic intraocular lens (PIOL) of - 4.5 D was characterized from its wavefront aberration profile. A preclinical study was conducted using pre- and post-surgery data from four patients that had undergone myopic laser refractive surgery. All these patients would have needed a PIOL of - 4.5 D. Pre-surgery data were used to simulate the effect of a PIOL implantation. Post myopic refractive surgery data were used to calculate the post-LASIK eye model. Modulation transfer function (MTF), point spread function (PSF) and simulation of optotypes vision were obtained and compared. The PIOL did not worsen the optical quality of the eyes evaluated. High order Aberrations were always higher in the post-LASIK eye model. Optics quality trended to be better in PIOL implantation than post-LASIK surgery as pupil size increased.
Collapse
Affiliation(s)
- Celia García
- grid.5268.90000 0001 2168 1800Grupo de Óptica y Percepción Visual (GOPV). Department of Optics, Pharmacology and Anatomy, University of Alicante, Crta San Vicente del Raspeig S/N, San Vicente del Raspeig, 03690 Alicante, Spain
| | - Vicente J. Camps
- grid.5268.90000 0001 2168 1800Grupo de Óptica y Percepción Visual (GOPV). Department of Optics, Pharmacology and Anatomy, University of Alicante, Crta San Vicente del Raspeig S/N, San Vicente del Raspeig, 03690 Alicante, Spain
| | - María T. Caballero
- grid.5268.90000 0001 2168 1800Grupo de Óptica y Percepción Visual (GOPV). Department of Optics, Pharmacology and Anatomy, University of Alicante, Crta San Vicente del Raspeig S/N, San Vicente del Raspeig, 03690 Alicante, Spain
| | - David P. Piñero
- grid.5268.90000 0001 2168 1800Grupo de Óptica y Percepción Visual (GOPV). Department of Optics, Pharmacology and Anatomy, University of Alicante, Crta San Vicente del Raspeig S/N, San Vicente del Raspeig, 03690 Alicante, Spain
| | - Pedro Tañá
- Oftalvist Alicante, Avinguda de Dénia, 103, 03015 Alicante, Spain
| | - Cristina Tello
- Oftalvist Alicante, Avinguda de Dénia, 103, 03015 Alicante, Spain
| | - Juan J. Miret
- grid.5268.90000 0001 2168 1800Grupo de Óptica y Percepción Visual (GOPV). Department of Optics, Pharmacology and Anatomy, University of Alicante, Crta San Vicente del Raspeig S/N, San Vicente del Raspeig, 03690 Alicante, Spain
| |
Collapse
|
68
|
Zhang D, Yang M, Liu Z, Cai H, Chen X, Zhang C. The effect of implantable collamer Lens V4c on ocular biometric measurements and intraocular lens power calculation based on Pentacam-AXL and IOLMaster 500. BMC Ophthalmol 2022; 22:421. [PMCID: PMC9637308 DOI: 10.1186/s12886-022-02644-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Accepted: 10/25/2022] [Indexed: 11/08/2022] Open
Abstract
Background To investigate the possible effect of implantable collamer lens (ICL) V4c on ocular biometric measurements by a new biometer Pentacam-AXL and partial coherence interferometry (PCI)-based IOLMaster 500 and intraocular lens power calculation using fourth-generation formula. Methods We retrospectively enrolled patients who underwent ICL (EVO-V4c, STAAR Surgical Co. Nidau, Switzerland) implantation surgery from September 2020 to November 2021. The Pentacam-AXL and IOLMaster 500 biometers were used to measure axial length (AL), anterior chamber depth (ACD), keratometry (K), white to white (WTW), and central corneal thickness (CCT) values before and at least 2 months after ICL V4c implantation. The IOL power was calculated using the Barrett Universal II formula. Results The study included 45 eyes in 28 patients. There was a significant increase in ALs (average 0.03 ± 0.07 mm, p = 0.01) and a significant decrease of ACDs (average 0.19 ± 0.17 mm, p < 0.001) based on Pentacam-AXL. Similar changes in ALs and ACDs were also found in IOLMaster 500. In addition, the difference in WTWs in the two devices and that of CCTs in Pentacam-AXL were statistically significant. However, the preoperative and postoperative K1 and K2 were separately comparable using either device. The IOL power calculated by the Barrett Universal II formula did not change significantly either by the software built in Pentacam-AXL or by manually putting the parameters of the IOLMaster 500 into the formula manually (p = 0.058, p = 0.675, respectively). Conclusions Ocular parameters including ALs, ACDs, WTWs, and CCTs using a new Pentacam-AXL and standard PCI-based IOLMaster 500 changed significantly before and after the ICL V4c implantation, while IOL power prediction using the Barrett Universal II formula was little affected.
Collapse
Affiliation(s)
- Di Zhang
- grid.411642.40000 0004 0605 3760Department of Ophthalmology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191 PR China ,grid.411642.40000 0004 0605 3760Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191 PR China
| | - Meng Yang
- Beijing Fenglian Jiayuelige Ophthalmic Clinic, 18 Chaoyangmenwai Street, Chaoyang District, Beijing, 100020 PR China
| | - Ziyuan Liu
- grid.411642.40000 0004 0605 3760Department of Ophthalmology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191 PR China ,grid.411642.40000 0004 0605 3760Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191 PR China
| | - Hongyuan Cai
- grid.411642.40000 0004 0605 3760Department of Ophthalmology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191 PR China ,grid.411642.40000 0004 0605 3760Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191 PR China
| | - Xiaoyong Chen
- grid.411642.40000 0004 0605 3760Department of Ophthalmology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191 PR China ,grid.411642.40000 0004 0605 3760Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191 PR China
| | - Chun Zhang
- grid.411642.40000 0004 0605 3760Department of Ophthalmology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191 PR China ,grid.411642.40000 0004 0605 3760Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191 PR China
| |
Collapse
|
69
|
Liu F, Xia F, Niu L, Zhao J, Wang X, Zhou X. Early Assessment of Circumferential Anterior Segment Structures Following Implantable Collamer Lens V4c Implantation Via SS-OCT. Transl Vis Sci Technol 2022; 11:4. [PMID: 36331273 PMCID: PMC9645365 DOI: 10.1167/tvst.11.11.4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Purpose To explore early changes in circumferential anterior segment structures following Implantable Collamer Lens (ICL) V4c implantation via swept-source optical coherence tomography (SS-OCT). Methods In 103 eyes of 56 myopic patients undergoing ICL V4c surgery, anterior segments were measured via SS-OCT to compute local anterior chamber angle (ACA) parameters on the nasal–temporal (0°–180°), superior–inferior (90°–270°), and superior nasal–inferior temporal (80°–260°) meridians, including angle-opening distance at 500 µm (AOD500), trabecular–iris space area at 500 µm (TISA500), trabecular–iris angle at 500 µm (TIA500), and circumferential ACA parameters, including AOD area at 500 µm (AODA500), trabecular–iris circumference volume at 500 µm (TICV500), and the index and area of iris–trabecular contact (ITC). ACA parameters were compared preoperatively and at 1 week, 1 month, and 3 months postoperatively and compared among quadrants. Mixed-effects model was used to evaluate the parameters correlated with the post-ITC parameters. Results The mean AOD500, TISA500, TIA500, AODA500, and TICV500 were decreased by 65.4% to 71%, 64.1% to 69.3%, 53.8% to 61.5%, 69.9%, and 69.2%, respectively, at 1 week postoperatively. The ITC index and area values rose from 1.436% ± 4.427% and 0.070 ± 0.254 mm2 to 12.343% ± 13.216% and 0.903 ± 1.304 mm2 (all P < 0.05). No further decreases in ACA parameters were observed beyond 1 week postoperatively (all P > 0.05). Significant differences were observed among quadrants, with the narrowest in the superior–nasal quadrant, followed by the superior quadrant. The 3-month vault was significantly correlated with the ITC index and area at 3 months postoperatively. Conclusions Anterior segment structures were significantly shallow at 1 week with no further decreases thereafter. In light of anatomical variability, we recommend circumferential meridian scan to assess angle status, with special attention to the superior–nasal and superior quadrants. Translational Relevance We investigated the early changes in circumferential anterior segment structures following ICL V4c implantation, thus providing a better perspective for understanding anterior segment structural characteristics after ICL V4c surgery.
Collapse
Affiliation(s)
- Fang Liu
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Fei Xia
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Lingling Niu
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Jing Zhao
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Xiaoying Wang
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Xingtao Zhou
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| |
Collapse
|
70
|
Savini G, Lupardi E, Hoffer KJ, Aramberri J, Schiano-Lomoriello D. Corneal diameter measurements by 3 optical biometers and their effect on phakic intraocular lens sizing. J Cataract Refract Surg 2022; 48:1292-1296. [PMID: 35616506 DOI: 10.1097/j.jcrs.0000000000000976] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Accepted: 05/22/2022] [Indexed: 11/26/2022]
Abstract
PURPOSE To compare phakic intraocular lens size calculations based on corneal diameter (CD) measurements by 3 instruments. SETTING G.B. Bietti Foundation I.R.C.C.S., Rome, Italy. DESIGN Retrospective interventional case series. METHODS Preoperatively, CD was measured with the Aladdin, IOLMaster 700, and Pentacam AXL Wave. The simulated ICL size was computed by entering CD measurements into the manufacturer's calculator. Postoperatively, vaulting was measured by anterior segment optical coherence tomography. The optimal ICL size (OIS) was calculated and compared with the commercially available OIS (CAOIS). RESULTS 54 eyes (29 patients) with the implantable collamer lens (ICL) were enrolled. The mean CD was 12.02 ± 0.36 mm with the Aladdin, 12.35 ± 0.39 mm with the IOLMaster 700, and 12.22 ± 0.41 mm with the Pentacam AXL Wave ( P &lt; .0001), with the closest agreement between the Pentacam AXL Wave and IOLMaster 700 (95% limits of agreement: -0.43 to +0.17 mm). Vaulting (mean: 558 ± 261 μm) was within 251 and 1000 μm in 49 eyes (83.3%). The mean difference between the simulated ICL size and OIS ranged between -0.11 ± 0.35 mm and 0.10 ± 0.30 mm ( P &lt; .0001), with no statistically significant difference between the IOLMaster 700 and Pentacam AXL Wave. The simulated ICL size was equal to CAOIS in 38 eyes (70.37%) with the Aladdin, 37 eyes (68.52%) with the IOLMaster 700, and 39 eyes (72.22%) with the Pentacam AXL Wave, without any statistically significant difference. CONCLUSIONS CD measurements by the 3 devices lead to similar percentages of eyes with an ICL size equal to the OIS. Agreement is closer between the IOLMaster 700 and Pentacam AXL Wave.
Collapse
Affiliation(s)
- Giacomo Savini
- From the I.R.C.C.S., G.B. Bietti Foundation, Rome, Italy (Savini, Schiano-Lomoriello); University Eye Clinic, S. Orsola-Malpighi Hospital, University of Bologna, Bologna, Italy (Lupardi); Stein Eye Institute, University of California, Los Angeles, California (Hoffer); St. Mary's Eye Center, Santa Monica, California (Hoffer); Clínica Miranza Begitek, San Sebastian and Clinica Miranza Ókular, Vitoria, Spain (Aramberri)
| | | | | | | | | |
Collapse
|
71
|
Martínez-Plaza E, López-Miguel A, López-de la Rosa A, Maldonado MJ. Inter-eye and postoperative prediction of vault after implantation of EVO + Visian phakic implantable collamer lens. Int Ophthalmol 2022; 43:1501-1510. [PMID: 36260197 DOI: 10.1007/s10792-022-02546-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Accepted: 10/06/2022] [Indexed: 11/25/2022]
Abstract
PURPOSE To assess whether the postoperative outcomes of the implantation of an EVO + implantable collamer lens (ICL) in one eye can be used as a predictor of the vault of the fellow eye, and to evaluate the vault changes of the implantation in both eyes during the postoperative period. METHODS A prospective study including 40 eyes of 20 patients with a bilateral EVO + ICL implantation was performed. Subjects were evaluated before the surgery and 1 day, 1 week and 1, 3 and 6 months postoperatively. Central vault was assessed using spectral-domain optical coherence tomography. The inter-eye and follow-up analyses were performed using lineal models and the Bland-Altman method. RESULTS The vault of the first implanted eye at the 1-day visit highly predicts the vault of the second eye (R2 = .87; P < .001); the mean inter-eye difference was - 0.95 μm, and the superior and inferior limits of agreement were -50.27 μm and 148.37 μm, respectively. This relationship was maintained during the medium-term follow-up, not finding differences in the slopes among visits (P ≥ .09). A progressive decrease of vault was found during the follow-up (P < .001). Larger vault change 6 months after the surgery was associated with higher vault 1 day after the ICL implantation (R2 = .19;P = .005). CONCLUSION One-day postoperative vault in the first eye can help to predict the optimal ICL sizing in the second eye. Vault tends to decrease during the first 6 months after EVO + ICL implantation. Eyes with higher initial vaults will also show larger reductions during the medium-term follow-up.
Collapse
Affiliation(s)
- Elena Martínez-Plaza
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Paseo de Belén 17, 47011, Valladolid, Spain
| | - Alberto López-Miguel
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Paseo de Belén 17, 47011, Valladolid, Spain.
- Red Temática de Investigación Colaborativa en Oftalmología (OftaRed), Instituto de Salud Carlos III, Madrid, Spain.
| | - Alberto López-de la Rosa
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Paseo de Belén 17, 47011, Valladolid, Spain
| | - Miguel J Maldonado
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Paseo de Belén 17, 47011, Valladolid, Spain
- Red Temática de Investigación Colaborativa en Oftalmología (OftaRed), Instituto de Salud Carlos III, Madrid, Spain
| |
Collapse
|
72
|
Silva R, Franqueira N, Faria-Correia F, Mendes J, Oliveira M, Monteiro T. Efficacy and safety after posterior chamber Implantable Collamer Lens implantation according to preoperative anterior chamber depth: Short-term comparative study. Eur J Ophthalmol 2022; 33:11206721221131889. [PMID: 36214139 DOI: 10.1177/11206721221131889] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/18/2024]
Abstract
PURPOSE To compare visual, refractive, and safety outcomes of posterior chamber Implantable Collamer Lens (ICL) implantation for the correction of myopia according to the preoperative anterior chamber depth (ACD). METHODS Retrospective, comparative study, patients submitted to implantation of myopic posterior-chamber phakic Implantable Collamer Lens (ICL), model V4C/V5, minimum follow-up of 12 months; two groups were created: Group 1 (ACD 2.80 to 2.99 mm) and Group 2 (ACD equal to or greater than 3.00 mm). The parameters evaluated were uncorrected and corrected visual acuity, subjective refraction, efficacy and safety index, predictability, endothelial cell density, central vault, anterior chamber angle and postoperative complications. A total of 558 eyes from 298 patients were evaluated: 111 eyes (19.9%) in group 1 and 447 eyes (80.1%) in group 2. RESULTS At 12 months, the efficacy index was similar in both groups (p = 0.264); the safety index was higher in group 1 (p = 0.031); the mean central Vault was significantly lower in group 1 (212.8 vs 410.6 μm; p < 0.001). Respectively, 93 (83.8%) and 366 (84.1%) eyes were within ±0.50 D of targeted refraction. Anterior chamber angle significantly decreased during follow-up in both groups (p < 0.001; p < 0.001). Intraocular pressure did not change significantly (p = 0.310 and p = 0.446, respectively). There were no significant differences in endothelial cell density loss (p = 0.278) or in the rate of complications observed (p = 0.733). CONCLUSIONS ICL implantation is an effective and safe procedure in eyes with shallow anterior chambers, with visual and refractive results and complication rates identical to those obtained in deeper anterior chambers.
Collapse
Affiliation(s)
- Rui Silva
- Department of Ophthalmology, 389794Hospital de Braga, Braga, Portugal
| | - Nuno Franqueira
- Department of Ophthalmology, 389794Hospital de Braga, Braga, Portugal
| | - Fernando Faria-Correia
- Department of Ophthalmology, 389794Hospital de Braga, Braga, Portugal
- 467460Life and Health Sciences Research Institute (ICVS), Escola de Medicina, Universidade do Minho, Braga, Portugal
| | - José Mendes
- Department of Ophthalmology, 389794Hospital de Braga, Braga, Portugal
- 467460Life and Health Sciences Research Institute (ICVS), Escola de Medicina, Universidade do Minho, Braga, Portugal
| | - Mariana Oliveira
- Department of Ophthalmology, 389794Hospital de Braga, Braga, Portugal
| | - Tiago Monteiro
- Department of Ophthalmology, 389794Hospital de Braga, Braga, Portugal
- 467460Life and Health Sciences Research Institute (ICVS), Escola de Medicina, Universidade do Minho, Braga, Portugal
| |
Collapse
|
73
|
Ang RET, Reyes EKF, Ayuyao FAJ, Umali MIN, Cruz EM. Comparison of white-to-white measurements using four devices and their determination of ICL sizing. EYE AND VISION (LONDON, ENGLAND) 2022; 9:36. [PMID: 36182955 PMCID: PMC9526955 DOI: 10.1186/s40662-022-00308-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/23/2022] [Accepted: 09/04/2022] [Indexed: 11/10/2022]
Abstract
BACKGROUND To compare the measurements obtained from the Orbscan II, IOLMaster 700, Pentacam AXL, and Castroviejo caliper and their effects on calculating the recommended implantable collamer lens (ICL) size and postoperative vault measurements. METHODS This is a retrospective cross-sectional study of patients who underwent ICL surgery by a single surgeon from March 1, 2018 to July 31, 2021. Records were reviewed for the anterior chamber depth (ACD) and white-to-white (WTW) measurements obtained from the Orbscan II, IOLMaster 700, Pentacam AXL, and Castroviejo caliper (WTW only). These were used to calculate the recommended ICL size. The actual ICL size implanted, and vault measurements obtained one month postoperatively were also collected. RESULTS One hundred seven eyes with a mean age of 27.9 ± 7.7 years were included in the study. Mean WTW measurements were significantly different between devices (P < 0.0001), with the IOLMaster 700 having the highest value (12.14 ± 0.04 mm) and the caliper having the lowest value (11.45 ± 0.04 mm). Mean ACD measurements were the lowest in Orbscan II (3.12 ± 0.25 mm) and the highest in Pentacam AXL (3.16 ± 0.24 mm). The Pentacam AXL produced an ICL size similar to the Orbscan in 69.2% of eyes. The IOLMaster yielded an ICL measurement one size larger than Orbscan-based calculations in 64.5% of eyes. Using the Orbscan WTW and ACD, the desired vault of 0.25 to 0.75 mm and 0.25 to 1.00 mm was achieved in 70% and 91% of eyes, respectively. Substituting caliper WTW to IOLMaster 700 or Pentacam AXL WTW increases the percentage of achieving the desired vault to 80%, similar to the Orbscan. CONCLUSIONS The Orbscan II, IOLMaster 700, and Pentacam AXL cannot be used interchangeably for calculating ICL sizing. Combining the WTW from caliper measurement with the ACD of the IOLMaster 700 or Pentacam AXL could improve ICL sizing and achieve a higher percentage of eyes with the desired vault.
Collapse
Affiliation(s)
- Robert Edward T. Ang
- grid.476917.a0000 0004 9154 7342Asian Eye Institute, Phinma Plaza, Rockwell Center, 8Th Floor, 1200 Makati, Philippines ,Cardinal Santos Medical Center, 10 Wilson St., Greenhills, 1502 San Juan, Philippines
| | | | - Fernando Amado J. Ayuyao
- grid.476917.a0000 0004 9154 7342Asian Eye Institute, Phinma Plaza, Rockwell Center, 8Th Floor, 1200 Makati, Philippines
| | - Maria Isabel N. Umali
- grid.476917.a0000 0004 9154 7342Asian Eye Institute, Phinma Plaza, Rockwell Center, 8Th Floor, 1200 Makati, Philippines
| | - Emerson M. Cruz
- grid.476917.a0000 0004 9154 7342Asian Eye Institute, Phinma Plaza, Rockwell Center, 8Th Floor, 1200 Makati, Philippines
| |
Collapse
|
74
|
Goes S, Delbeke H. Posterior chamber toric implantable collamer lenses vs LASIK for myopia and astigmatism: systematic review. J Cataract Refract Surg 2022; 48:1204-1210. [PMID: 36179351 DOI: 10.1097/j.jcrs.0000000000001007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Accepted: 07/05/2022] [Indexed: 11/26/2022]
Abstract
This systematic review compares the visual and refractive outcome of laser in situ keratomileusis with (toric) implantable collamer lens (ICL) in the treatment of myopic astigmatism. An electronic literature search led to 19 comparative articles. Refractive outcome, efficacy, safety, predictability, and stability as well as differences in contrast sensitivity and higher-order aberrations (HOAs) were analyzed for moderate (-3 to -6 diopters [D]) and high (≥-6 D) myopia. Results were either significantly in favor of (toric)-ICL or equal. Fewer HOAs and better contrast sensitivity after (toric)-ICL seem to be the largest asset in its refractive and clinical superiority. However, longer follow-up studies are indicated, specifically for systematically comparing long-term adverse effects.
Collapse
Affiliation(s)
- Stéphanie Goes
- From the Department of Ophthalmology, University Hospitals Leuven, Leuven, Belgium (Goes, Delbeke); KU Leuven, Biomedical Sciences Group, Department of Neurosciences, Research group Ophthalmology, Leuven, Belgium (Delbeke)
| | | |
Collapse
|
75
|
Zhang J, Shao J, Zheng L, Zhao X, Chen S. Implantable collamer lens sizing based on measurement of the sulcus-to-sulcus distance in ultrasound biomicroscopy video clips and ZZ ICL formula. BMC Ophthalmol 2022; 22:363. [PMID: 36071422 PMCID: PMC9454160 DOI: 10.1186/s12886-022-02583-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Accepted: 08/29/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND To evaluate a new method of implantable collamer lens (ICL) sizing based on ultrasound biomicroscopy (UBM) video clips. METHODS This observational study included consecutive patients with myopia and myopic astigmatism scheduled for V4c toric ICL (TICL) implantation (STAAR) at Hangzhou MSK Eye Hospital (October 2020 to November 2020). Sulcus-to-sulcus (STS) distance, lens thickness (LT), and clinical refraction were measured preoperatively. The ZZ ICL formula (provides the predicted vault height and refraction based on TICL size, intraocular meridian, power, and eye parameters, including STS distance and LT) was used to select TICL size and predict vault height and residual refraction, which was also compared with the STAAR software recommended. Vault and residual refraction were measured at 3 months postoperatively. RESULTS The analysis included 168 eyes in 84 patients. Postoperative vault size was comparable to that predicted by the ZZ ICL formula (528 ± 193 vs. 545 ± 156 μm, P = 0.227). Vault prediction error (PE) by the ZZ ICL formula was within 100, 300, and 500 μm in 40.48%, 88.10%, and 100% of eyes, respectively. Spherical equivalent (SE) and absolute cylindrical refractive error were 0.36 ± 0.48 and 0.40 ± 0.31 D at 3 months postoperatively. The SE PE, absolute cylindrical PE, and percentages of eyes with an absolute cylindrical PE within ± 0.50 D and ± 1.00 D were lower for the ZZ ICL formula than for the STAAR software (P < 0.01). CONCLUSIONS Combining measurements obtained in UBM video clips with the ZZ ICL formula provides an effective method of sizing TICLs and predicting vault height and residual refractive error.
Collapse
Affiliation(s)
- Jun Zhang
- Department of Ophthalmology, Hangzhou MSK Eye Hospital & MSK Eye Hospital of Hangzhou Medical College, Hangzhou, China.
| | - Jie Shao
- Department of Ophthalmology, Hangzhou MSK Eye Hospital & MSK Eye Hospital of Hangzhou Medical College, Hangzhou, China
| | - Li Zheng
- Department of Ophthalmology, Hangzhou MSK Eye Hospital & MSK Eye Hospital of Hangzhou Medical College, Hangzhou, China
| | - Xia Zhao
- Department of Ophthalmology, Hangzhou MSK Eye Hospital & MSK Eye Hospital of Hangzhou Medical College, Hangzhou, China
| | - Shu Chen
- Department of Ophthalmology, Hangzhou MSK Eye Hospital & MSK Eye Hospital of Hangzhou Medical College, Hangzhou, China
| |
Collapse
|
76
|
Chen X, Chen F, Wang X, Xu Y, Cheng M, Han T, Wang X, Zhou X. Safety and anterior chamber structure of evolution implantable Collamer lens implantation with short white-to-white corneal diameters. Front Med (Lausanne) 2022; 9:928245. [PMID: 36059823 PMCID: PMC9428310 DOI: 10.3389/fmed.2022.928245] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Accepted: 07/29/2022] [Indexed: 11/13/2022] Open
Abstract
Introduction To evaluate the safety and anterior chamber structure of implantation of the Evolution (EVO) implantable Collamer lens (EVO-ICL) in patients with short white-to-white (WTW) corneal diameters. Materials and methods The study population was divided into two groups: the experimental group (34 eyes of 34 patients) with WTW corneal diameters of ≤10.6 mm and the control group (59 eyes of 59 patients) with WTW corneal diameters of >10.6 mm. The outcome measures included uncorrected distance visual acuity, corrected distance visual acuity, refractive power, intraocular pressure (IOP), anterior chamber angle, depth, volume, and vault. Results The safety indices of the experimental and control groups were 1.17 ± 0.30 and 1.12 ± 0.14, respectively (P > 0.05); the effectiveness indices were 1.16 ± 0.31 and 1.07 ± 0.17, respectively (P > 0.05). The simulation curves of the expected and actual corrections in the experimental and control groups were y = 0.9876x – 0.0927 and y = 0.9799x + 0.0343, respectively. There were no significant differences between the IOPs and anterior chamber structures of the two groups (P > 0.05). The average vaults of the experimental and control groups were 395.76 ± 155.32 and 389.49 ± 135.01 μm, respectively (P > 0.05). Conclusion EVO-ICL implantation in patients with short WTW corneal diameters (≤ 10.6 mm) was determined to be a safe, effective, and predictable method for correcting myopia. The changes in the anterior chamber structure were still within normal limits after the surgery, the IOP remained stable, and the ideal vault was achieved after the surgery.
Collapse
Affiliation(s)
- Xun Chen
- Fudan University Eye Ear Nose and Throat Hospital, Shanghai, China
- National Health Commission Key Lab of Myopia, Fudan University, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Fang Chen
- The First People's Hospital of Zhaoqing, Zhaoqing, China
| | - Xuanqi Wang
- Fudan University Eye Ear Nose and Throat Hospital, Shanghai, China
- National Health Commission Key Lab of Myopia, Fudan University, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Yilin Xu
- Fudan University Eye Ear Nose and Throat Hospital, Shanghai, China
- National Health Commission Key Lab of Myopia, Fudan University, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Mingrui Cheng
- Fudan University Eye Ear Nose and Throat Hospital, Shanghai, China
- National Health Commission Key Lab of Myopia, Fudan University, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Tian Han
- Fudan University Eye Ear Nose and Throat Hospital, Shanghai, China
- National Health Commission Key Lab of Myopia, Fudan University, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Xiaoying Wang
- Fudan University Eye Ear Nose and Throat Hospital, Shanghai, China
- National Health Commission Key Lab of Myopia, Fudan University, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Xingtao Zhou
- Fudan University Eye Ear Nose and Throat Hospital, Shanghai, China
- National Health Commission Key Lab of Myopia, Fudan University, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| |
Collapse
|
77
|
Yang Z, Meng L, Zhao X, Chen Y, Luo Y. Clinical Prediction of Inadequate Vault in Eyes With Thick Lens After Implantable Collamer Lens Implantation Using Iris Morphology. Front Med (Lausanne) 2022; 9:906433. [PMID: 35755051 PMCID: PMC9218336 DOI: 10.3389/fmed.2022.906433] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Accepted: 05/23/2022] [Indexed: 12/01/2022] Open
Abstract
Background Obtaining an ideal vault is crucial in the implantable collamer lens (ICL) surgery. Prediction of the vault value is difficult since it requires the integration of multiple factors. The purpose of this study was to investigate the association between the iris shape and vault value in eyes with thick lens. Methods The study was conducted in Peking Union Medical College Hospital. Patients who received ICL V4c between 2017 and 2021 were screened. Eyes with thick lens (>4.0 mm) and abnormal iris shape (concave or convex) were included. The preoperative biometric parameters and postoperative vault value were compared between eyes with concave shape group and convex shape group. The relationship between various factors and vault was assessed by spearman rank analysis and multiple linear regression analysis. Representative cases our strategies to deal with the abnormal vault were demonstrated. Results Twenty eight eyes of 14 patients with thick lens and concave or convex shape iris were eventually included, with 14 eyes of 7 patients in group 1 (concave shape iris) and the other 14 eyes of 7 patients in group 2 (convex shape iris). The mean vault of group 1 was (0.16 ± 0.07) mm, which was significantly lower than (0.88 ± 0.13) mm in group 2. Multiple linear regression analysis showed iris shape (P < 0.001) was only the explanatory variables associated with the postoperative vault. In group1, 4 eyes showed extremely large ACA, requiring a secondary surgical intervention. So all of them underwent ICL exchange for a larger ICL. In group2, the ICL was implanted in a vertical or oblique position to avoid or rescue an extremely large vault. Conclusion Concave shape iris had a higher risk of low vault and convex shape iris were more likely to demonstrate high vault in eyes with thick lens. Exchanging ICL for the larger size and adjusting ICL to the vertical or oblique orientation are good option to rescue the low or high vault, respectively.
Collapse
Affiliation(s)
- Zhikun Yang
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, China
| | - Lihui Meng
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, China.,Key Lab of Ocular Fundus Diseases, Chinese Academy of Medical Sciences, Beijing, China
| | - Xinyu Zhao
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, China.,Key Lab of Ocular Fundus Diseases, Chinese Academy of Medical Sciences, Beijing, China
| | - Youxin Chen
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, China.,Key Lab of Ocular Fundus Diseases, Chinese Academy of Medical Sciences, Beijing, China
| | - Yan Luo
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, China
| |
Collapse
|
78
|
Warjri GB, Senthil S. Imaging of the Ciliary Body: A Major Review. Semin Ophthalmol 2022; 37:711-723. [PMID: 35695216 DOI: 10.1080/08820538.2022.2085515] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
PURPOSE We conducted a systematic search of literature to understand the various methods of imaging of the ciliary body. METHODS PubMed, Science Direct, Cochrane Library and Google Scholar were searched comprehensively and systematically to find studies related to the various modalities of ciliary body imaging. RESULTS The various ciliary body parameters that have been described are Ciliary body thickness, Ciliary body length, ciliary muscle thickness, ciliary process length, ciliary muscle length, ciliary muscle anterior length, trabecular ciliary process distance and Iris ciliary process distance. The various angles which have been measured, which mostly have a significance in Primary angle closure glaucoma (PACG) are Iris ciliary angle, Trabecular ciliary angle, scleral ciliary process angle. Various authors have defined them in various ways with subtle differences. Plateau iris and PACG mechanisms, not forgetting malignant glaucoma are better understood with imaging of the ciliary body using the ultrasound biomicroscopy (UBM). The anterior segment optical coherence tomography (ASOCT) imaging of the ciliary body has been described albeit with its own disadvantages. A few other fields dependant on the importance of ciliary body imaging are intravitreal injections, pars plana vitrectomy, measurements for implantable collamer lens (ICL) and of utmost importance, the differentiating features of ciliary body masses. CONCLUSION The UBM is still preferred over the ASOCT for imaging of the ciliary body. A lot of lacunae of knowledge still exists and consensus has to be reached on defining all the parameters universally. Future studies will be able to shed more light on the role of the ciliary body in the many ocular disorders mentioned in this review.
Collapse
Affiliation(s)
| | - Sirisha Senthil
- VST Centre for Glaucoma Services, L V Prasad Eye Institute, Hyderabad, India
| |
Collapse
|
79
|
Li Y, Zheng F, Foo LL, Wong QY, Ting D, Hoang QV, Chong R, Ang M, Wong CW. Advances in OCT Imaging in Myopia and Pathologic Myopia. Diagnostics (Basel) 2022; 12:diagnostics12061418. [PMID: 35741230 PMCID: PMC9221645 DOI: 10.3390/diagnostics12061418] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Revised: 06/06/2022] [Accepted: 06/06/2022] [Indexed: 11/16/2022] Open
Abstract
Advances in imaging with optical coherence tomography (OCT) and optical coherence tomography angiography (OCTA) technology, including the development of swept source OCT/OCTA, widefield or ultra-widefield systems, have greatly improved the understanding, diagnosis, and treatment of myopia and myopia-related complications. Anterior segment OCT is useful for imaging the anterior segment of myopes, providing the basis for implantable collamer lens optimization, or detecting intraocular lens decentration in high myopic patients. OCT has enhanced imaging of vitreous properties, and measurement of choroidal thickness in myopic eyes. Widefield OCT systems have greatly improved the visualization of peripheral retinal lesions and have enabled the evaluation of wide staphyloma and ocular curvature. Based on OCT imaging, a new classification system and guidelines for the management of myopic traction maculopathy have been proposed; different dome-shaped macula morphologies have been described; and myopia-related abnormalities in the optic nerve and peripapillary region have been demonstrated. OCTA can quantitatively evaluate the retinal microvasculature and choriocapillaris, which is useful for the early detection of myopic choroidal neovascularization and the evaluation of anti-vascular endothelial growth factor therapy in these patients. In addition, the application of artificial intelligence in OCT/OCTA imaging in myopia has achieved promising results.
Collapse
Affiliation(s)
- Yong Li
- Singapore National Eye Centre, Singapore Eye Research Institute, Singapore 169856, Singapore; (Y.L.); (F.Z.); (L.L.F.); (Q.Y.W.); (D.T.); (Q.V.H.); (R.C.); (M.A.)
- Ophthalmology and Visual Sciences Academic Clinical Program, Duke-NUS Medical School, Singapore 169857, Singapore
| | - Feihui Zheng
- Singapore National Eye Centre, Singapore Eye Research Institute, Singapore 169856, Singapore; (Y.L.); (F.Z.); (L.L.F.); (Q.Y.W.); (D.T.); (Q.V.H.); (R.C.); (M.A.)
| | - Li Lian Foo
- Singapore National Eye Centre, Singapore Eye Research Institute, Singapore 169856, Singapore; (Y.L.); (F.Z.); (L.L.F.); (Q.Y.W.); (D.T.); (Q.V.H.); (R.C.); (M.A.)
- Ophthalmology and Visual Sciences Academic Clinical Program, Duke-NUS Medical School, Singapore 169857, Singapore
| | - Qiu Ying Wong
- Singapore National Eye Centre, Singapore Eye Research Institute, Singapore 169856, Singapore; (Y.L.); (F.Z.); (L.L.F.); (Q.Y.W.); (D.T.); (Q.V.H.); (R.C.); (M.A.)
| | - Daniel Ting
- Singapore National Eye Centre, Singapore Eye Research Institute, Singapore 169856, Singapore; (Y.L.); (F.Z.); (L.L.F.); (Q.Y.W.); (D.T.); (Q.V.H.); (R.C.); (M.A.)
- Ophthalmology and Visual Sciences Academic Clinical Program, Duke-NUS Medical School, Singapore 169857, Singapore
| | - Quan V. Hoang
- Singapore National Eye Centre, Singapore Eye Research Institute, Singapore 169856, Singapore; (Y.L.); (F.Z.); (L.L.F.); (Q.Y.W.); (D.T.); (Q.V.H.); (R.C.); (M.A.)
- Ophthalmology and Visual Sciences Academic Clinical Program, Duke-NUS Medical School, Singapore 169857, Singapore
- Department of Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore 119077, Singapore
- Department of Ophthalmology, Columbia University, New York, NY 10027, USA
| | - Rachel Chong
- Singapore National Eye Centre, Singapore Eye Research Institute, Singapore 169856, Singapore; (Y.L.); (F.Z.); (L.L.F.); (Q.Y.W.); (D.T.); (Q.V.H.); (R.C.); (M.A.)
- Ophthalmology and Visual Sciences Academic Clinical Program, Duke-NUS Medical School, Singapore 169857, Singapore
| | - Marcus Ang
- Singapore National Eye Centre, Singapore Eye Research Institute, Singapore 169856, Singapore; (Y.L.); (F.Z.); (L.L.F.); (Q.Y.W.); (D.T.); (Q.V.H.); (R.C.); (M.A.)
- Ophthalmology and Visual Sciences Academic Clinical Program, Duke-NUS Medical School, Singapore 169857, Singapore
| | - Chee Wai Wong
- Singapore National Eye Centre, Singapore Eye Research Institute, Singapore 169856, Singapore; (Y.L.); (F.Z.); (L.L.F.); (Q.Y.W.); (D.T.); (Q.V.H.); (R.C.); (M.A.)
- Ophthalmology and Visual Sciences Academic Clinical Program, Duke-NUS Medical School, Singapore 169857, Singapore
- Correspondence:
| |
Collapse
|
80
|
Packer M. Evaluation of the EVO/EVO+ Sphere and Toric Visian ICL: Six Month Results from the United States Food and Drug Administration Clinical Trial. Clin Ophthalmol 2022; 16:1541-1553. [PMID: 35645557 PMCID: PMC9132105 DOI: 10.2147/opth.s369467] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Accepted: 05/13/2022] [Indexed: 12/29/2022] Open
Abstract
Purpose To evaluate the safety and effectiveness of Collamer posterior chamber phakic refractive lenses with a central port design (EVO and EVO+ Sphere and Toric Visian ICLs) for correction of moderate-to-high myopia with or without astigmatism. Patients and Methods Six-month results of a multicenter clinical trial performed under United States FDA Investigational Device Exemption. Subjects 21 through 45 years of age with myopia ranging from -3.00 D to -20.00 D and astigmatism up to 4.00 D underwent implantation of EVO or EVO+ Sphere or Toric Visian ICLs. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, manifest refraction, intraocular pressure (IOP), endothelial cell density, and adverse events were evaluated over 6 months. Results This clinical trial enrolled 629 eyes of 327 subjects with mean age 35.6 ± 5.09 years. Mean preoperative spherical equivalent (SE) measured -7.62 ± 2.75 D (range: -3.00 to -15.62 D). At 6 months, mean SE was -0.079 ± 0.33 D, with 90.5% within ± 0.50 D of target and 98.9% within ±1.00 D of target. Mean postoperative UDVA and CDVA were -0.059 ± 0.10 logMAR and -0.13 ± 0.08 logMAR, respectively. 52.3% of eyes gained lines of CDVA. Efficacy and safety indices were 1.06 and 1.24, respectively. No eye experienced pupillary block, required peripheral iridotomy or iridectomy, developed anterior subcapsular cataract or had elevated IOP due to angle narrowing or pigment dispersion. Mean endothelial cell density declined by 2.3%. Conclusion EVO ICL lenses demonstrated accuracy of refractive correction and achievement of high levels of UDVA. This clinical trial confirmed that the central port design of EVO and EVO+ Sphere and Toric Visian ICL lenses functions effectively to allow physiologic flow of aqueous humor, thus eliminating the requirement for preoperative peripheral iridotomies. The results of this clinical trial resulted in FDA approval on March 25, 2022.
Collapse
Affiliation(s)
- Mark Packer
- Packer Research Associates, Boulder, CO, USA
| |
Collapse
|
81
|
Packer KT, Vlasov A, Greenburg DL, Coggin A, Weightman JW, Beltran T, Berry-Cabán CS, Carroll RB. U.S. military implantable collamer lens surgical outcomes: 11-year retrospective review. J Cataract Refract Surg 2022; 48:649-656. [PMID: 34653095 DOI: 10.1097/j.jcrs.0000000000000818] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Accepted: 09/10/2021] [Indexed: 11/26/2022]
Abstract
PURPOSE To examine the long-term efficacy and safety of myopic implantable collamer lens (ICL) implantation in active duty personnel of U.S. military. SETTING Hospital practice. DESIGN Retrospective longitudinal observational study. METHODS 1485 patients (median age 25, interquartile range 22 to 29) underwent ICL surgery. Patients received a preoperative examination including uncorrected distance visual acuity (UDVA), intraocular pressure (IOP), manifest refraction measuring corrected distance visual acuity (CDVA), corneal topography and tomography, qualitative grading of perceived ectatic risk, ophthalmic biometry, and baseline endothelial cell counts (ECCs). Outcome measures included UDVA, IOP, vault size, manifest refraction, CDVA, and ECCs. The long-term follow-up data ware drawn from the U.S. military medical record system. RESULTS A total of 3105 eyes were evaluated. Patients received ICLs because of either abnormal topography (2111 eyes [68%]) or high myopia (994 eyes [32%]). 94 eyes (80%) maintained UDVA of 20/25 or better up to 8 years postoperatively. The rate of achieving the desired refractive correction was 97% (503 eyes) at 1 year and 90% (81 eyes) at 8 years. Stability of these outcomes was also shown by minimal change in manifest refraction. Documented mean ECC loss was 22% at postoperative year 5. The overall rate of adverse events was 1.2% (36 eyes) including visually significant cataract formation, glaucoma, retinal detachment, and traumatic incision opening. A removal or replacement rate of 4.5% (135 eyes) was observed. CONCLUSIONS ICL implantation was found to be effective and safe. Vault sizes decreased over time, suggesting an increased risk of cataract formation after 7 years. Further study is necessary to assess long-term clinical significance of ECC decline.
Collapse
Affiliation(s)
- Kyle T Packer
- From the Department of Ophthalmology, Womack Army Medical Center, Fort Bragg, North Carolina (Packer, Vlasov, Greenburg, Coggin, Weightman, Carroll); Department of Clinical Investigation, Womack Army Medical Center, Fort Bragg, North Carolina (Beltran, Berry-Cabán)
| | | | | | | | | | | | | | | |
Collapse
|
82
|
One-year analysis of the refractive stability, axial elongation and related factors in a high myopia population after Implantable Collamer Lens implantation. Int Ophthalmol 2022; 42:3295-3302. [PMID: 35590026 DOI: 10.1007/s10792-022-02328-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Accepted: 04/18/2022] [Indexed: 10/18/2022]
Abstract
PURPOSE To investigate the refractive stability, axial length (AL) changes and their related factors in a high myopia population after Implantable Collamer Lens (ICL) implantation. METHODS This prospective study included 116 eyes of 116 patients divided into several groups based on the spherical equivalent refractive error (SE)-SE > - 6 D, - 12 ≤ SE < - 6 D and SE < - 12 D groups-and AL-AL < 28 mm and AL ≥ 28 mm groups. The uncorrected and corrected distance visual acuity, refraction, AL and intraocular pressure were followed for 1 year. RESULTS SE changed from - 11.53 ± 5.25 D preoperatively to - 0.33 ± 0.70 D at 1 week, and further changed to - 0.48 ± 0.77 D at 1 year after ICL implantation, with average progression being - 0.15 ± 0.37 D from 1 week to 1 year after surgery. AL changed from 27.95 ± 2.33 mm preoperatively to 27.98 ± 2.36 mm 1 year after surgery, with an average axial elongation of 0.03 ± 0.12 mm. The mean axial elongation rate was 0.05 mm/year in the SE < - 12 D group, being significantly faster than the other refractive groups (P < 0.05); it was 0.06 mm/year in the AL ≥ 28 mm group, being significantly faster than the AL < 28 mm group (P < 0.05). CONCLUSION Patients with high myopia and long AL showed a continuous myopic progression and axial elongation at an adult age one year after ICL surgery, especially in those with myopia higher than - 12.00 D and AL longer than 28.00 mm.
Collapse
|
83
|
Fu M, Li M, Xian Y, Yu Z, Zhang H, Choi J, Niu L, Wang X, Zhou X. Two-Year Visual Outcomes of Evolution Implantable Collamer Lens and Small Incision Lenticule Extraction for the Correction of Low Myopia. Front Med (Lausanne) 2022; 9:780000. [PMID: 35492322 PMCID: PMC9043127 DOI: 10.3389/fmed.2022.780000] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2021] [Accepted: 03/07/2022] [Indexed: 11/26/2022] Open
Abstract
Purpose To investigate the 2-year visual quality of Evolution Implantable Collamer Lens (EVO-ICL) and small incision lenticule extraction (SMILE) for the correction of low myopia. Methods In this prospective study, we included 25 eyes of 25 patients (7 men) who underwent EVO-ICL and 36 eyes of 36 patients (16 men) who underwent SMILE between January 2018 and December 2018. Subjective and objective visual outcomes were compared between ICL and SMILE. All patients were followed for 2 years. Results At the postoperative 2-year visit, the percentage of patients with uncorrected distance visual acuity (UDVA) greater than or equal to preoperative corrected distance visual acuity (CDVA) was comparable in the ICL group (80%, 20/25) and SMILE group (88.89%, 32/36). Spherical equivalent (SE) was within ± 0.50 D in 96% (24/25) of the ICL group and 94.44% (34/36) of the SMILE group. No eyes lost more than 2 lines of CDVA. Postoperative high-order aberrations (HOAs) were significantly increased in the ICL group (p < 0.01) and in the SMILE group (p < 0.01). The most common visual complaint was halo after ICL and starburst after SMILE. There was no correlation between HOAs and visual complaints (p > 0.05). Conclusion Evolution Implantable Collamer Lens provides comparable safety, efficacy, long-term visual stability, and high patient satisfaction when compared to SMILE in correcting low myopia. EVO-ICL could be a favorable alternative for low myopia. Key messages What was known? What this paper adds?
Collapse
Affiliation(s)
| | - Meiyan Li
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia, Fudan University, Shanghai, China.,Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Yiyong Xian
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia, Fudan University, Shanghai, China.,Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Zhiqiang Yu
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia, Fudan University, Shanghai, China.,Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | | | - Joanne Choi
- Wayne State University School of Medicine, Detroit, MI, United States
| | - Lingling Niu
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia, Fudan University, Shanghai, China.,Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Xiaoying Wang
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia, Fudan University, Shanghai, China.,Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Xingtao Zhou
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia, Fudan University, Shanghai, China.,Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| |
Collapse
|
84
|
Wei R, Cheng M, Niu L, Wang L, Luo X, Li M, Zhou X, Wang X, Zhou X, Yao P. Outcomes of the EVO ICL Using a Customized Non-horizontal or Horizontal Implanting Orientation Based on UBM Measurement: A Pilot Study. Ophthalmol Ther 2022; 11:1187-1198. [PMID: 35415777 PMCID: PMC9114204 DOI: 10.1007/s40123-022-00498-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2022] [Accepted: 03/08/2022] [Indexed: 11/27/2022] Open
Abstract
Introduction To evaluate the short-term safety and efficacy of the EVO implantable collamer lens (ICL) using a customized implanting orientation design based on ultrasound biomicroscope (UBM) measurement. Methods The prospective case series included 310 eyes of 158 patients treated with ICL. To achieve an optimal vault, an ICL of specific size was chosen and implanted in a customized orientation according to assessment of sulcus-to-sulcus (STS) diameters, distance between STS plane and crystalline lens (STSL), the morphology of ciliary sulcus (MCS), anterior chamber depth (ACD), and white-to-white (WTW). With the new design, there were 138 eyes with a non-horizontal orientation and 172 eyes with a horizontal orientation of the ICL. Refractive and ICL vault statuses were followed up for 1 day and 1 month postoperatively. Results The safety index at 1 month was 1.34 ± 0.17 for the non-horizontally implanted group and 1.33 ± 0.16 for the horizontally implanted group; the efficacy index was 1.21 ± 0.18 for the non-horizontally implanted group and 1.18 ± 0.16 for the horizontally implanted group. All eyes achieved an uncorrected distance visual acuity of 0.10 logMAR or better. No significant difference in endothelial cell density was observed between the preoperative value (2792.6 ± 247.6 cells/mm2) and value at 1 month postoperatively (2744.2 ± 243.3 cells/mm2), and no cataract or anterior subcapsular opacification was observed. Ideal vault (250–750 μm) was achieved in 84% of eyes (260/310). Conclusion The customized ICL design of implanting orientation based on UBM measurement provides good safety, efficacy, and vault predictability. Supplementary Information The online version contains supplementary material available at 10.1007/s40123-022-00498-8.
Collapse
Affiliation(s)
- Ruoyan Wei
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia, Fudan University, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Mingrui Cheng
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia, Fudan University, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Department of Ophthalmology, Jinshan Hospital Affiliated To Fudan University, Shanghai, China
| | - Lingling Niu
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia, Fudan University, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Lin Wang
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia, Fudan University, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Xiumei Luo
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia, Fudan University, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Meiyan Li
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia, Fudan University, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Xiaodong Zhou
- Department of Ophthalmology, Jinshan Hospital Affiliated To Fudan University, Shanghai, China
| | - Xiaoying Wang
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia, Fudan University, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Xingtao Zhou
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China.
- NHC Key Laboratory of Myopia, Fudan University, Shanghai, China.
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China.
| | - Peijun Yao
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China.
- NHC Key Laboratory of Myopia, Fudan University, Shanghai, China.
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China.
| |
Collapse
|
85
|
Multicenter clinical outcomes of hole implantable collamer lens implantation in middle-aged patients. Sci Rep 2022; 12:4236. [PMID: 35273340 PMCID: PMC8913835 DOI: 10.1038/s41598-022-08298-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Accepted: 03/01/2022] [Indexed: 11/19/2022] Open
Abstract
To assess the multicenter clinical outcomes of the implantation of hole implantable collamer lens (Hole ICL, ICL KS-AquaPORTTM; STAAR Surgical, Nidau, Switzerland) in patients of 45 years or more. We retrospectively assessed the surgery’s safety, efficacy, predictability, stability, and adverse events before surgery and after the surgery at 1 week; 1, 3, and 6 months; and 1 year, followed by once every year for approximately 2.2 years. A total of 118 eyes of 65 patients aged 45–65 years with myopic refractive errors ranging from − 2.13 to − 18.75 diopters (D) underwent hole ICL implantation and routine postoperative examinations. The average observation period was 2.2 ± 1.0 years. The safety and efficacy indices were 1.08 ± 0.21 and 0.87 ± 0.25, respectively. Manifest refraction changes of − 0.20 ± 0.43 D occurred from 1 month to the final visit after ICL implantation. Eight eyes (6.8%) developed asymptomatic anterior subcapsular cataract (ASC) immediately after surgery, and three eyes (2.5%) developed clinically significant symptomatic nuclear cataracts during the follow-up period. According to our experience, hole ICL implantation offered favorable outcomes in all measures of safety, efficacy, predictability, and stability, even in middle-aged patients, during the 2.2-year observation period.
Collapse
|
86
|
Nonpassopon M, Jongkhajornpong P, Phimpho P, Cheewaruangroj N, Lekhanont K, Chuckpaiwong V. Agreement of implantable collamer lens sizes using parameters from different devices. BMJ Open Ophthalmol 2022; 7:e000941. [PMID: 35372697 PMCID: PMC8905975 DOI: 10.1136/bmjophth-2021-000941] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Accepted: 02/25/2022] [Indexed: 11/11/2022] Open
Abstract
Objective To assess agreement and repeatability of white-to-white (WTW) and anterior chamber depth (ACD), and agreement of implantable collamer lens (ICL) size using these measurements from different devices. Methods and analysis A retrospective review of 83 eyes with ICL implantation (42 patients) was conducted. The agreement of WTW (measured with WaveLight Topolyzer and Orbscan IIz) and ACD (measured with WaveLight Oculyzer and Orbscan IIz) was analysed. Correlation of ICL sizes and difference of eyes with unacceptable vaults between two data sets (WaveLight platform; Topolyzer and Oculyzer and Orbscan IIz) were assessed. Results Average WTW measured by Orbscan IIz and Topolyzer demonstrated good agreement (Ρ 0.884) with low systematic bias (−0.03±0.1 mm) and narrow 95% limits of agreement (LoA) of −0.28 to 0.22. Average ACD measured by Orbscan IIz and Oculyzer also showed good agreement (Ρ 0.903) with low systematic bias (−0.04±0.1 mm) and relatively narrow 95% LoA (0.2 to 0.12). ICL size selected according to two data sets showed moderate to strong level of agreement (Kappa=0.81). There was a statistically significant difference (p<0.001) in the proportion of eyes with unacceptable postoperative vaults when using the Wavelight platform data set (five eyes, 6.02%) and the Orbscan IIz data set (12 eyes, 14.46%). Conclusion Although the agreement of WTW and ACD between devices was good, there was a significant difference in proportion of eyes with unacceptable postoperative vaults when using two data sets. Therefore, Topolyzer and Oculyzer might not be suitable for operating interchangeably with Orbscan IIz for ICL size selection.
Collapse
Affiliation(s)
- Manachai Nonpassopon
- Department of Ophthalmology, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand
| | - Passara Jongkhajornpong
- Department of Ophthalmology, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand
| | - Prae Phimpho
- Department of Ophthalmology, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand
| | - Nontawat Cheewaruangroj
- Department of Ophthalmology, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand
| | - Kaevalin Lekhanont
- Department of Ophthalmology, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand
| | - Varintorn Chuckpaiwong
- Department of Ophthalmology, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand
| |
Collapse
|
87
|
Teplovodskaya VV, Sobolev NP, Morina NA, Zhuravlev AS, Sudakova EP. [Correction of ametropia with posterior chamber phakic intraocular lens]. Vestn Oftalmol 2022; 138:64-70. [PMID: 35234423 DOI: 10.17116/oftalma202213801164] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Posterior chamber phakic intraocular lens (PIOL) implantation is a widely accepted and performed refractive surgery for correction of moderate and high myopia used when corneal laser ablation procedures are not suitable. This paper analyzes literature data to reveal the advantages and limitations of the technology.
Collapse
Affiliation(s)
- V V Teplovodskaya
- S.N. Fedorov National Medical Research Center «MNTK «Eye Microsurgery», Moscow, Russia
| | - N P Sobolev
- S.N. Fedorov National Medical Research Center «MNTK «Eye Microsurgery», Moscow, Russia
| | - N A Morina
- S.N. Fedorov National Medical Research Center «MNTK «Eye Microsurgery», Moscow, Russia
| | - A S Zhuravlev
- S.N. Fedorov National Medical Research Center «MNTK «Eye Microsurgery», Moscow, Russia
| | - E P Sudakova
- I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
| |
Collapse
|
88
|
Martínez-Plaza E, López-Miguel A, López-de la Rosa A, McAlinden C, Fernández I, Maldonado MJ. EVO+ Implantable Collamer Lens KS-aquaPORT Location, Stability, and Impact on Quality of Vision and Life. J Refract Surg 2022; 38:177-183. [PMID: 35275006 DOI: 10.3928/1081597x-20220106-01] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
PURPOSE To determine the longitudinal variation in the KS-aquaPORT central hole location of the phakic EVO+I Implantable Collamer Lens (ICL) (STAAR Surgical) and analyze its influence on visual performance, quality of vision (QoV), and quality of life (QoL). METHODS A prospective study was performed including 36 patients who had EVO+ ICL implantation. The KS-aquaPORT central hole location (Cartesian and polar coordinates) was determined with respect to the pupil center and visual axis. The effect of time (6-month follow-up) on central hole location was analyzed using linear mixed models. The effect of the KS-aquaPORT location on visual performance, QoV, and QoL parameters was assessed with multivariate regression models. RESULTS With respect to the visual axis, no significant changes in KS-aquaPORT location were found during follow-up. With respect to the pupil center, the X-coordinate and radius of KS-aquaPORT location showed modest, but significant (P ≤ .05) differences between 1-week and 3-month postoperative visits, and between 1-week and 6-month visits. X-coordinate variation was significant (P = .022) between 1-and 6-month visits. With respect to the visual axis, greater KS-aquaPORT decentration was associated with worse visual acuity (X-coordinate: P = .004; radius: P = .006), and inferior decentration with longer xenon-type glare photostress recovery time (P = .021). With respect to the pupil center, a lower radius was associated with better QoV scores (P ≤ .01) and temporal decentration produced higher ring-shaped dysphotopsia (P = .007). CONCLUSIONS EVO+ ICL KS-aquaPORT location appears to be clinically stable up to 6 months postoperatively. A central location of the EVO+ ICL KS-aquaPORT hole is preferred because it allows reduced perception of dysphotopic phenomena that can result in better QoV. [J Refract Surg. 2022;38(3):177-183.].
Collapse
|
89
|
Kojima T, Kitazawa Y, Nakamura T, Kamiya K, Ichikawa K, Igarashi A, Shimizu K. Multicenter survey on implantable collamer lens dislocation. PLoS One 2022; 17:e0264015. [PMID: 35157743 PMCID: PMC8843229 DOI: 10.1371/journal.pone.0264015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Accepted: 01/31/2022] [Indexed: 11/18/2022] Open
Abstract
This study aimed to investigate the incidence, patient background, and postoperative prognosis of implantable collamer lens (ICL) dislocation. We retrospectively reviewed all cases of ICL dislocation at four major refractive surgery centers in Japan until December 2019. The incidence, patient background, cause of dislocation, complications of repositioning surgery, and postoperative visual function were investigated. Seven ICL dislocations [0.072% of total ICL-implanted eyes (9775 eyes)] occurred at an average of 28.6 months (11–82 months) postoperatively. All patients were male. Five eyes were injured during sports activities, one due to a fall from a bicycle, and another due to ocular blunt trauma caused by a mortuary tablet. Two patients had re-dislocation in the same eye. Retinal detachment occurred after repositioning surgery in one patient, and scleral buckling surgery was performed without ICL removal. ICL dislocation is a rare complication of ICL surgery; repositioning surgery is effective, but retinal complications may occur.
Collapse
Affiliation(s)
| | | | | | - Kazutaka Kamiya
- Department of Ophthalmology, University of Kitasato School of Medicine, Kanagawa, Japan
| | | | | | - Kimiya Shimizu
- Department of Ophthalmology, Sanno Hospital, Tokyo, Japan
| |
Collapse
|
90
|
Intraoperative Adjustment of Implantable Collamer Lens Vault by Lens Rotation Aided by intraoperative Optical Coherence Tomography. J Cataract Refract Surg 2022; 48:999-1003. [PMID: 35171140 DOI: 10.1097/j.jcrs.0000000000000915] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Accepted: 02/08/2022] [Indexed: 11/25/2022]
Abstract
PURPOSE To assess the use of intraoperative optical coherence tomography (OCT) to detect high vault during implantation surgery and guide intraoperative vault adjustment by ICL rotation. SETTING Instituto Zaldivar SA. Mendoza, Argentina. DESIGN Prospective, single-arm, observational study. METHODS A total of 25 eyes of 25 consecutive patients showing high intraoperative vault who undergone Implantable Collamer Lens (ICL) rotation from horizontal to vertical or oblique position were evaluated. Central ICL vault was measured both intraoperatively using the microscope-integrated iOCT (Optomedical Technologies GmbH, Luebeck, Germany, merged with Haag-Streit Surgical GmbH & Co. KG in May 2020) mounted on a standard surgical microscope (HS Hi-R NEO 900A NIR, Haag-Streit Surgical GmbH & Co. KG, Wedel, Germany), and postoperatively using the Casia 2 swept-source OCT (Tomey GmbH, Nürnberg, Germany) at 4 hours, 1 day and 1 month. RESULTS Mean vault value obtained intraoperatively was 1147.88±188.36 μm and changed significantly to 739.76 ± 194.97 μm after lens rotation to either vertical (n=19, 76% of cases) or oblique (n=6, 24% of cases) positions (mean difference 408.12 ± 213.57 μm, p < 0.001). There was significant relationship between the amount of change due to lens rotation with white-to-white distance (r=-0.480, p=0.015) and vault before rotation (r=-0.564, p=0.003). Mean vault values were 758.40±187.10 μm, 729.73±227.86 μm and 661.88±275.17 μm at 4 hours, 24 hours and 1-month post-surgery, respectively. CONCLUSIONS Intraoperative adjustment of ICL vault by lens rotation using intraoperative OCT is an effective procedure to obtain an optimal vault.
Collapse
|
91
|
Long-term follow-up for monovision surgery by Implantable Collamer Lens V4c implantation for myopia correction in early presbyopia. Graefes Arch Clin Exp Ophthalmol 2022; 260:2763-2771. [PMID: 35129628 PMCID: PMC9325784 DOI: 10.1007/s00417-021-05545-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Revised: 12/13/2021] [Accepted: 12/27/2021] [Indexed: 11/15/2022] Open
Abstract
Purpose To investigate the long-term safety and efficacy of monovision surgery using implantable collamer lens V4c (ICL V4c) implantation in myopic patients with early presbyopia. Setting Eye and ENT Hospital of Fudan University, Shanghai, China. Design Prospective case series study. Methods This study included 64 eyes of 32 patients with early presbyopia, who underwent bilateral ICL V4c implantation for myopia correction. Parameters, including mean spherical equivalent (SE), uncorrected distance visual acuity, corrected distance visual acuity, intraocular pressure, endothelial cell density, presbyopic add power, visual acuity (logMAR) of dominant eyes (D-eye), nondominant (nD-eye) eyes, and both eyes (Bi) at 0.4 m, 0.8 m, and 5 m were recorded at the last follow-up. Results All surgeries were uneventful. At the last follow-up, the safety indices were 1.23 ± 0.18 (D-eyes) and 1.21 ± 0.18 (nD-eyes) (p > 0.05); the efficacy indices were 0.95 ± 0.27 (D-eyes) and 0.92 ± 0.28 (nD-eyes) (p < 0.05), the SE was -0.62 ± 0.47 D (D-eyes); and − 1.21 ± 0.78D (nD-eyes) (p < 0.05), presbyopic add power was 1.31 ± 0.58 D. The visual acuity (logMAR) of D-eyes, nD-eyes, and binocular (Bi) at 5.0 m were: 0.06 ± 0.15 (D-eye), 0.21 ± 0.18 (nD-eye), (p < 0.01), and 0.04 ± 0.13 (Bi); 0.8 m: 0.03 ± 0.18 (D-eye), 0.08 ± 0.16 (nD-eye), (p > 0.05), and − 0.02 ± 0.11 (Bi); 0.4 m: 0.08 ± 0.09 (D-eye), − 0.02 ± 0.08 (nD-eye), (p < 0.001), and − 0.03 ± 0.09 (Bi). Subjects were very satisfied or felt excellent with their visual acuity at near (81.25%) and far distances (87.50%), respectively (versus preoperative, p < 0.001). Conclusion Monovision surgery using ICL V4c implantation is safe and practicable for correction of myopes with presbyopia, with long-term efficacy at near and far distances and patient satisfaction. ![]()
Collapse
|
92
|
Changes of ocular biometry in eyes with posterior chamber phakic intraocular lens implantation. J Fr Ophtalmol 2022; 45:377-383. [PMID: 35093264 DOI: 10.1016/j.jfo.2021.10.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2021] [Revised: 10/17/2021] [Accepted: 10/24/2021] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To evaluate changes in biometric variables and intraocular lens (IOL) calculation results after posterior chamber phakic IOL (PCPIOL) implantation. METHODS This retrospective, observational study included 65 eyes of 38 patients who underwent PCPIOL (EVO Visian ICL) implantation for correction of myopia. Prior to and a minimum of one year (mean 14.9 months) after EVO Visian ICL implantation, biometric variables and IOL calculation results were compared. Optical biometry, including anterior chamber depth, axial length, flat, steep, and mean keratometry values and IOL calculation results for the Holladay 2, Hoffer Q, Haigis, and SRK/T formulas were measured using the IOLMaster 700 SWEPT Source OCT biometer. MAIN RESULTS The mean anterior chamber depth decreased from 3.70±0.22mm to 3.34±0.39mm, the mean axial length increased from 26.61±1.61mm to 26.71±1.66mm, and the mean flat keratometry changed from 42.82±1.86 D to 42.73±1.83 D. These changes were statistically significant. The mean IOL power calculation also revealed a statistically significant decrease with all four formulas (ranging from 0.19 D to 0.30 D) after PCPIOL implantation. CONCLUSIONS Biometric variables and IOL calculation results showed statistically significant changes one year after EVO Visian ICL implantations. However, IOL power calculations yielded a decrease of less than 0.50 D, inducing much less refractive deviation in the spectacle plane; and the change was primarily related to an increase in AL measurements. IOL power calculations in eyes with EVO Visian ICL in situ provided satisfactory and reliable results.
Collapse
|
93
|
Guan N, Zhang XN, Zhang WJ. Correlation between intraoperative and postoperative vaulting of the EVO implantable Collamer lens: a retrospective study of real-time observations of vaulting using the RESCAN 700 system. BMC Ophthalmol 2022; 22:2. [PMID: 34980022 PMCID: PMC8721482 DOI: 10.1186/s12886-021-02237-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2020] [Accepted: 12/22/2021] [Indexed: 12/19/2022] Open
Abstract
Background Implantable Collamer lens (ICL) vaulting is one of the most important parameters for the safety, aqueous humor circulation, and lens transparency after ICL implantation. This study aimed to investigate the factors associated with the actual vaulting after refractive EVO-ICL surgery. Methods This retrospective study included patients who underwent EVO-ICL surgery at a tertiary eye hospital between October and December 2019. A RESCAN 700 was used for the intraoperative and CIRRUS HD-OCT was used for postoperative observation of vaulting. Subjective and objective refractions, anterior ocular segment, corneal morphology, intraocular pressure (IOP), anterior chamber volume (ACV), crystalline lens rise (CLR), white-to-white distance (WTW), anterior chamber depth (ACD), axial length, corneal endothelial cell density (ECD), and fundoscopy were examined. A multivariable analysis was performed to determine the factors independently associated with 1-month postoperative vaulting. Results Fifty-one patients (102 eyes) were included. Compared with the eyes with normal vaulting, those with high vaulting had higher preoperative diopter values (P = 0.039), lower preoperative corrected visual acuity (P = 0.006), lower preoperative IOP (P = 0.029), higher preoperative ACD (P = 0.004), lower preoperative CLR (P = 0.046), higher ICL spherical equivalent (P = 0.030), higher intraoperative vaulting (P < 0.001), and lower IOP at 1 month (P = 0.045). The multivariable analysis showed that the only factor independently associated with high vaulting at 1 month after surgery was the intraoperative vaulting value (odds ratio = 1.005, 95% confidence interval: 1.002–1.007, P < 0.001). The intraoperative and 1-month postoperative vaulting values were positively correlated (R2 = 0.562). Conclusions The RESCAN700 system can be used to perform intraoperative optical coherence tomography to predict the vaulting value of ICL at 1 month.
Collapse
Affiliation(s)
- Nian Guan
- Department of Refractive, Wuhan Bright Eye Hospital, Wuhan, 430000, Hubei, China
| | - Xiao-Nong Zhang
- Department of Refractive, Hefei Bright Eye Hospital, Hefei, 230000, Anhui, China
| | - Wan-Jun Zhang
- Department of Refractive, Hefei Bright Eye Hospital, Hefei, 230000, Anhui, China.
| |
Collapse
|
94
|
Wang XJ, Chen D, Jiang Y, Chou YY, Luo Y, Li Y, Ma J, Zhong Y. The 100 most influential articles in myopia: a bibliometric analysis. Int J Ophthalmol 2022; 15:150-156. [PMID: 35047370 PMCID: PMC8720343 DOI: 10.18240/ijo.2022.01.22] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Accepted: 03/16/2021] [Indexed: 02/08/2023] Open
Abstract
AIM To identify and characterize the 100 most influential articles in the field of myopia over the last decades. METHODS Articles on myopia published between January 1975 and March 2020 were searched through the Web of Science Core Collection database. Two independent authors reviewed and determined the 100 most cited articles. The characteristics of each eligible article were recorded, including authors, institutions, countries, journals, publication date, total citations (TCs), annual citations (ACs), research focus and article type. RESULTS The top 100 most influential articles were published between 1983 and 2016, with 1999 as the most prolific year. The mean number of TCs was 288 (range: 193-537) and the mean number of ACs was 19 (range: 7-109). Treatment and epidemiology of myopia were the most important research focus. These articles were published in 21 journals led by Ophthalmology (29%) followed by Investigative Ophthalmology & Visual Science (23%). The number of ACs for articles published in the last ten years was significantly higher than that for the other most-cited articles (44 vs 16, Mann-Whitney U test P<0.01). There is no difference in the number of TCs between original articles and review articles, while the number of ACs for review articles was significantly higher than that for original articles (22 vs 17, Mann-Whitney U test P<0.05). CONCLUSION This bibliometric analysis can provide us with concise information about the development trend of research in the field of myopia in the past few decades, and provide an important reference for researchers to guide future research.
Collapse
Affiliation(s)
- Xue-Jiao Wang
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China
| | - Di Chen
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China
| | - Yang Jiang
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China
| | - Yu-Yu Chou
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China
| | - Yan Luo
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China
| | - Ying Li
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China
| | - Jin Ma
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China
| | - Yong Zhong
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China
| |
Collapse
|
95
|
First Experiences with Implantation of Phakic Lenses in Correction of Myopia in R. N. Macedonia. Pril (Makedon Akad Nauk Umet Odd Med Nauki) 2021; 42:37-46. [PMID: 35032378 DOI: 10.2478/prilozi-2021-0033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Objective: Analysis of visual acuity parameters in patients with moderate to high myopia and myopic astigmatism 1 year after treatment with phakic intraocular lenses. Material and methods: This was a retrospective study on 35 patients (52 eyes) with moderate to high myopia who were implanted with the Visian V4c phakic implantable Collamer lens (Staar Surgical, Nidau, Switzerland). Examined parameters were: uncorrected distance visual acuity (UDVA) and best corrected visual acuity (CDVA), manifest and cycloplegic refraction, intraocular pressure, and endothelial cell count. The investigated parameters were measured preoperatively, 1, 3, 6 and 12 months postoperatively. Results: In 17 patients, phakic lenses were implanted binocularly and in 18 patients monocularly. Preoperatively 34.62% of patients had CDVA from 0.9 to 1.0. One year after the surgery 48.08% of patients had UDVA from 0.9 to 1.0. Preoperatively 80.77% of patients had diopter range from -6.00 Dsph to -10.00 Dsph. At 1 year postoperatively 78.85% of patients were within 0.00 Dsph to -1.00 Dsph. Preoperatively, in patients with astigmatism -4 Dcyl to -2 Dcyl dominated, as opposed to significant improvement postoperatively when 94.23% had astigmatism ranging from -1.0 Dcyl to 0 Dcyl. Conclusion: The implantation of phakic lenses demonstrated a successful postoperative outcome in the treatment of myopia and myopic astigmatism. Visual acuity and refraction show a gradual and significant improvement in visual function parameters within 1 year of lens implantation.
Collapse
|
96
|
Xu G, Wu G, Du Z, Zhu S, Guo Y, Yu H, Hu Y. Distribution of White-to-White Corneal Diameter and Anterior Chamber Depth in Chinese Myopic Patients. Front Med (Lausanne) 2021; 8:732719. [PMID: 34869427 PMCID: PMC8639187 DOI: 10.3389/fmed.2021.732719] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Accepted: 10/22/2021] [Indexed: 11/13/2022] Open
Abstract
Purpose: To investigate the distribution of white-to-white (WTW) corneal diameter and anterior chamber depth (ACD) in Chinese myopia patients. Methods: This was a cross-sectional observational study conducted at five ophthalmic centers. Anterior segment biometry was performed in 7,893 eyes of the 7,893 myopic patients using Pentacam, and the WTW and ACD were recorded. The distribution patterns of WTW and ACD were evaluated and the correlation between WTW and ACD was analyzed statistically. Results: There were 4416 (55.95%) males and 3477 (44.05%) females. The age of the study population was 25.14 ± 5.41 years. Distribution of WTW was slightly positively skewed (Skewness = 0.0076, Kurtosis = 0.3944, KS P = 0.020) with a mean of 11.65 ± 0.38 mm and a 95% normal range of 10.91-12.39 mm. A significant difference in WTW was found among different myopia groups (P < 0.001). The ACD was normally distributed (Skewness = 0.899, Kurtosis = 0.027, KS P = 0.086). The mean ACD was 3.25 ± 0.26 mm and the 95% normal range of was 2.74-3.75 mm. A significant difference in ACD was also found among different myopia groups (P = 0.030). There was a significant correlation between WTW and ACD (r = 0.460, P < 0.001). Conclusions: In our study, 95% of the Chinese myopic patients had a WTW within 10.91-12.39 mm and an ACD within 2.74-3.75 mm. ACD and WTW were significantly different among different myopia, gender and age groups. WTW was positively correlated with ACD.
Collapse
Affiliation(s)
- Guihua Xu
- Department of Ophthalmology, Huizhou Municipal Central Hospital, Huizhou, China
| | - Guanrong Wu
- Department of Ophthalmology, Guangdong Eye Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China
| | - Zijing Du
- Department of Ophthalmology, Guangdong Eye Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China
| | - Shanqing Zhu
- Aier Institute of Refractive Surgery, Refractive Surgery Center, Guangzhou Aier Eye Hospital, Guangzhou, China
| | - Yunxiang Guo
- Aier Institute of Refractive Surgery, Refractive Surgery Center, Guangzhou Aier Eye Hospital, Guangzhou, China
| | - Honghua Yu
- Department of Ophthalmology, Guangdong Eye Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China
| | - Yijun Hu
- Department of Ophthalmology, Guangdong Eye Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China.,Aier Institute of Refractive Surgery, Refractive Surgery Center, Guangzhou Aier Eye Hospital, Guangzhou, China.,Aier School of Ophthalmology, Central South University, Changsha, China
| |
Collapse
|
97
|
A Comparative Study of Two Types of Implantation Surgery Methods for Implantable Collamer Lenses. J Ophthalmol 2021; 2021:4074773. [PMID: 34845422 PMCID: PMC8627330 DOI: 10.1155/2021/4074773] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Revised: 07/09/2021] [Accepted: 11/06/2021] [Indexed: 11/17/2022] Open
Abstract
Purpose To investigate the effects of two different surgical methods of implantable collamer lens (ICL) implantation on the operation time, visual outcomes, corneal endothelial cell count, and intraocular pressure (IOP). Methods This was a contralateral eye comparison study, a total of 192 eyes from 96 patients were included, and the two eyes from the same patient were randomly assigned to two groups (group 1 and group 2, with 96 eyes in each group). In group 1, after making the corneal incision, ophthalmic viscosurgical devices (OVDs) were first injected into the anterior chamber followed by ICL implantation. In group 2, the ICL was first implanted into the anterior chamber followed by OVDs injection. The operation time, uncorrected distance visual acuity, corrected distance visual acuity, spherical equivalent, corneal endothelial cell count, and IOP were recorded and analyzed. Results The operative time in group 1 was significantly longer than that in group 2 (P = 0.002 < 0.05). There were significant differences between IOP measured 2 hours following surgery of the two groups (P = 0.026 < 0.05), Furthermore, the rate of IOP change 2 hours following the operation was significantly higher in group 1 than in group 2 (P = 0.019 < 0.05). There were significant differences in the anterior chamber angle 2 hours after surgery compared with that before surgery in both groups (P = 0.014 < 0.05 and P = 0.029 < 0.05, respectively). No significant differences were observed in the other parameters measured (all P > 0.05). Conclusion The two ICL implantation methods had similar clinical outcomes and effects on the corneal endothelial cell count. Additionally, the implantation of an intraocular lens prior to injecting OVDs reduces the operation time and lowers the rate of IOP rise in the early postoperative period, making it safe and effective for ICL implantation.
Collapse
|
98
|
Alhamzah A, Alharbi SS, Alfardan F, Aldebasi T, Almudhaiyan T. Indications for exchange or explantation of phakic implantable collamer lens with central port in patients with and without keratoconus. Int J Ophthalmol 2021; 14:1714-1720. [PMID: 34804861 DOI: 10.18240/ijo.2021.11.10] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2021] [Accepted: 06/16/2021] [Indexed: 11/23/2022] Open
Abstract
AIM To evaluate the causes of phakic implantable collamer lens (ICL) exchange/explantation in patients with and without keratoconus (KC) at two tertiary hospitals in Riyadh, Saudi Arabia. METHODS A retrospective chart review of all patients who underwent ICL (model V4c with central port) exchange/explantation was performed using the electronic medical record systems. All available preoperative and postoperative data were documented for each patient. RESULTS Over 7y, 2283 ICL implantation procedures were performed; 46 implants (2%) required exchange (21 implants)/explantation (25 implants), of which 14 cases (30.4%) were patients with KC. Indications for ICL exchange/explantation in non-KC group were vault measurement, cataract formation, increased intraocular pressure, inaccurate refraction, and patient dissatisfaction in 22 (68.75%), 4 (12.5%), 3 (9.37%), 2 (6.25%), and 1 (3.12%) case, respectively. The most common indication for ICL exchange/explantation in the KC group was inaccurate vault sizing in 11 patients (78.57%), inaccurate refraction in 2 patients (14.28%), and patient dissatisfaction postoperatively in 1 (7.14%) case. CONCLUSION ICL implantation results in predictable refractive outcomes over the long term with exchange/explantation rates comparable to previous literature. Improper vault size is the most common cause of ICL exchange/explantation among patients with or without KC.
Collapse
Affiliation(s)
- Albanderi Alhamzah
- King Saud bin Abdulaziz University for Health Sciences, College of Medicine, Riyadh 22490, Saudi Arabia
| | - Saad S Alharbi
- Anerior Segment Department, King Khaled Eye Specialist Hospital, Riyadh 7191, Saudi Arabia
| | - Fahad Alfardan
- Department of Surgery, Division of Ophthalmology, National Guard Hospital, Riyadh 22490, Saudi Arabia.,King Abdullah International Medical Research Center, Riyadh 22490, Saudi Arabia
| | - Tariq Aldebasi
- Department of Surgery, Division of Ophthalmology, National Guard Hospital, Riyadh 22490, Saudi Arabia
| | - Tariq Almudhaiyan
- Department of Surgery, Division of Ophthalmology, National Guard Hospital, Riyadh 22490, Saudi Arabia.,King Abdullah International Medical Research Center, Riyadh 22490, Saudi Arabia
| |
Collapse
|
99
|
Evaluation of Visual Outcome of 2 Phakic Posterior Chamber Implantable Lenses in High Myopia: A Comparative Study. Eye Contact Lens 2021; 48:38-44. [PMID: 34775453 DOI: 10.1097/icl.0000000000000854] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/09/2021] [Indexed: 10/19/2022]
Abstract
PURPOSE To evaluate and compare the visual outcomes of two phakic intraocular lenses in high myopia. METHODS A prospective comparative study was undertaken on 50 eyes of 26 patients {age ≥21 years and divided into two groups (implantable collamer lens [ICL] V4c, n=25 eyes and refractive implantable lens [RIL], n=25 eyes)}. Patients were evaluated for uncorrected distance visual acuity (UCVA), best-corrected distance visual acuity, manifest refractive spherical equivalent (MRSE), contrast sensitivity, intraocular pressure, dilated fundus examination, trabecular-iris angle (TIA), anterior chamber depth, horizontal white-to-white diameter, wavefront aberrometry, and endothelial cell (EC) count. All patients were followed up until 6 months and additionally evaluated for anterior chamber inflammation, cataract, and lens vault. RESULTS The baseline parameters (UCVA, MRSE, and EC count) and postoperative improvement in UCVA, contrast sensitivity, MRSE, EC loss, safety index, and efficacy index were comparable between both the lenses. The improvement in aberrometric profile was significantly better in the ICL group. The mean postoperative vault was higher in RIL group (434.88±162.48 μm vs. 547.24±159.83 μm, P=0.0173); however, the vault was within normal range in both the groups. The decrease in mean TIA was significantly higher in RIL group (8.58 vs. 13.45 μm, P=0.0073). CONCLUSION Acrylic phakic lens can be considered as a suitable alternative to collamer lens for refractive correction of high myopia. The collamer lenses showed slight superiority in some qualitative visual parameters; however, collamer lenses do not present with subjective complaints in the patients.
Collapse
|
100
|
Duch F, López-Marín I, Alonso-Aliste F, Hernández-Barahona-Campos M, Manito SC, Sánchez-Trancón Á, Cadarso L, Sánchez-González JM, Fernández J. Influence of tomographic and biomechanical corneal indexes on myopic refractive surgery indications: A multicenter study. Eur J Ophthalmol 2021; 32:2630-2637. [PMID: 34751040 DOI: 10.1177/11206721211054725] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
PURPOSE To evaluate the influence of corneal tomographic and biomechanical indexes on the refractive technique indication. METHODS A total of 251 eyes from 251 patients interested in refractive surgery were enrolled in this cross-sectional and multicenter study. Previous to the surgeon decision, a preoperative protocol was performed by refractive optometrists, containing four sections: refraction, biometry, corneal tomography and biomechanics. The refractive surgeons made a first decision based only on refraction, biometric and tomographic information. Biomechanical indexes were revealed, and refractive surgeons made a second indication. Additionally, for Laser-Assisted in-situ Keratomileusis cases, the percent tissue altered were calculated. Possible indications were no refractive surgery, photorefractive keratectomy, Laser-Assisted in-situ Keratomileusis or intraocular Collamer lens. RESULTS After the first surgery indication, the distribution was photorefractive keratectomy (47.4%), Laser-Assisted in-situ Keratomileusis (48.2%) while intraocular Collamer lens achieved 2.8%. This proportion changed significantly after the second indication regarding corneal biomechanics and photorefractive keratectomy and Laser-Assisted in-situ Keratomileusis decreased by 24% while intraocular Collamer lens increased 19%. A total of 69 eyes changed the indication (27.5%) and 182 eyes (72.5%) remained unchanged. All indications changes were from photorefractive keratectomy or Laser-Assisted in-situ Keratomileusis to intraocular Collamer lens or no surgery. Indication changes to intraocular Collamer lens were observed in 49 eyes (71%). Tomographic, biomechanical indexes, ablation depth and percent tissue altered achieved statistically significant differences between eyes without and with indication changes (all, P < .01). CONCLUSION New corneal biomechanical indexes could change the indication decision regarding biometric and tomographic data alone. Intraocular Collamer len was the preferred indication for eyes at risk of ectasia or with subclinical keratoconus due to corneal biomechanical parameters.
Collapse
Affiliation(s)
- Francesc Duch
- Refractive Surgery Department, 537040Institut Català de Retina, Spain
| | | | | | | | | | | | - Luís Cadarso
- Refractive Surgery Department, Cadarso Clinic, Spain
| | - José-María Sánchez-González
- Refractive Surgery Department, Tecnolaser Clinic Vision, Spain.,Physics of Condensed Matter Department, Optics Area, 16778University of Seville, Spain
| | - Joaquín Fernández
- Refractive Surgery Department, Qvision, 221663Vithas Virgen del Mar Hospital, Spain
| |
Collapse
|