Ruth AL, Lynn MJ, Randleman JB, Stulting RD. Blade source effect on laser in situ keratomileusis flap thickness with the Amadeus I microkeratome. J Cataract Refract Surg 2008; 34:407-10. [PMID: 18299064 DOI: 10.1016/j.jcrs.2007.11.020] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2007] [Accepted: 11/01/2007] [Indexed: 10/22/2022]
Abstract
PURPOSE To determine the effect of different blades on laser in situ keratomileusis (LASIK) flap thickness created with the Amadeus I microkeratome (Ziemer Ophthalmic Systems). SETTING Emory University Department of Ophthalmology and Emory Vision, Atlanta, Georgia, USA. METHODS This retrospective nonrandomized comparative case study from January 2005 through June 2006 compared LASIK flap thickness created with blades from 2 manufacturers: the Surepass from Surgical Instrument Systems and distributed by AMO and the ML7090 CLB distributed by Med-Logics, Inc. Sex, preoperative corneal thickness, surgical-eye sequence, flap thickness and variance, and residual stromal bed were evaluated in each group. RESULTS This study evaluated 424 eyes of 226 patients. Surepass blades were used in 238 eyes and ML7090 CLB blades in 186 eyes. There were no significant differences between the 2 blade groups in preoperative corneal thickness, sex, or cases with corneal thickness greater than 550 microm. Mean flap thickness and variance were significantly lower in the ML7090 CLB group than in the Surepass group (P<.0001). There were no significant differences in flap thickness in either group based on sex; however, in both groups, flap thickness was significantly lower in second eyes and in eyes with a preoperative thickness less than 550 microm (P<.001). CONCLUSIONS The Amadeus I microkeratome created thinner, more consistent LASIK flaps with the ML7090 CLB blade than with the Surepass blade. Preoperative corneal thickness and eye sequence affected flap thickness, while sex did not.
Collapse
Affiliation(s)
- Adrienne L Ruth
- Emory University Department of Ophthalmology, Rollins School of Public Health at Emory University, Atlanta, Georgia, USA
| | | | | | | |
Collapse
|
53
|
Kim JH, Lee D, Rhee KI. Flap thickness reproducibility in laser in situ keratomileusis with a femtosecond laser: optical coherence tomography measurement. J Cataract Refract Surg 2008; 34:132-6. [PMID: 18165093 DOI: 10.1016/j.jcrs.2007.08.036] [Citation(s) in RCA: 59] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2007] [Accepted: 06/28/2007] [Indexed: 10/22/2022]
Abstract
PURPOSE To compare ultrasound (US) pachymetry, Orbscan, and optical coherence tomography (OCT) measurements of the central corneal thickness (CCT) before laser in situ keratomileusis (LASIK) and evaluate the reproducibility of flaps created with the IntraLase femtosecond laser (IntraLase, Inc.) using OCT. SETTING Department of Ophthalmology, IIsan Paik Hospital, Goyang, Korea. METHODS Central corneal thickness was measured using OCT, US pachymetry, and Orbscan in 59 eyes of 30 patients before femtosecond laser LASIK. The postoperative corneal flap thickness, measured using OCT, was compared with the preoperative intended thickness. RESULTS Optical coherence tomography, US pachymetry, and Orbscan measurements provided similar CCT values (P>.05). Corneal thickness values obtained using US or Orbscan correlated well with those obtained by OCT, with the correlation coefficient ranging from 0.804 to 0.889 (P<.05). The OCT measurements showed no significant difference between the postoperative flap thickness and the intended flap thickness (P>.05). CONCLUSIONS Optical coherence tomography was comparable to US pachymetry and Orbscan in cornea thickness measurement. Optical coherence tomography was easy and relatively accurate to use preoperatively and in the early postoperative period. The femtosecond laser created highly reproducible flaps that corresponded with the preoperative intended thickness.
Collapse
Affiliation(s)
- Jin-Hyoung Kim
- Department of Ophthalmology, Ilsan Paik Hospital, Inje University College of Medicine, Goyang-si, Korea.
| | | | | |
Collapse
|
54
|
Binder PS, Sarayba M, Ignacio T, Juhasz T, Kurtz R. Characterization of submicrojoule femtosecond laser corneal tissue dissection. J Cataract Refract Surg 2008; 34:146-52. [PMID: 18165095 DOI: 10.1016/j.jcrs.2007.07.056] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2007] [Accepted: 07/30/2007] [Indexed: 11/18/2022]
|
55
|
Caster AI, Friess DW, Potvin RJ. Absence of Keratectasia After LASIK in Eyes With Preoperative Central Corneal Thickness of 450 to 500 Microns. J Refract Surg 2007; 23:782-8. [DOI: 10.3928/1081-597x-20071001-07] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
56
|
Hoffart L, Proust H, Matonti F, Catanèse M, Conrath J, Ridings B. Kératoplastie lamellaire antérieure assistée par laser femtoseconde. J Fr Ophtalmol 2007; 30:689-94. [PMID: 17878821 DOI: 10.1016/s0181-5512(07)91356-x] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
INTRODUCTION Automated lamellar keratoplasty remains a challenging surgical technique because of surgical difficulties and is associated with a high rate of complications. The precision of the corneal cut at any corneal depth with the femtosecond laser is an important improvement in this technique. We report the first case of femtosecond-assisted anterior lamellar keratoplasty. MATERIAL AND METHODS A 63-year-old woman with anterior stromal dystrophy underwent femtosecond laser-assisted ALTK on the left eye. A donor lenticula was prepared from a corneoscleral rim utilizing the Femtec 20/10 Perfectvision femtosecond laser device and an artificial anterior chamber (Moria, Antony, France). The anterior lamellar cut was also performed on the patient's eye with the femtosecond laser. RESULTS Postoperative examinations showed a well-adapted graft with a clear interface. OCT III (Carl Zeiss Meditech, Dublin) measurements showed a corneal pachymetry of 713 microm associated with a regular posterior bed and a central thickness of 132 microm. DISCUSSION Femtosecond laser corneal cutting may offer greater safety, reproducibility, predictability, and flexibility. The risks of irregular cutting and microperforation are reduced. A better graft congruence can limit the risk of secondary displacement and the smooth interface should improve visual results. CONCLUSION Donor lenticulae and corneal cuttings performed with the Femtec 20/10 Perfectvision( femtosecond laser device can be used in the successful management of eyes requiring anterior lamellar keratoplasty. Further studies are needed to evaluate outcomes of this procedure.
Collapse
Affiliation(s)
- L Hoffart
- Service d'Ophtalmologie, Hôpital de la Timone, Marseille, France.
| | | | | | | | | | | |
Collapse
|
57
|
Binder PS. Analysis of ectasia after laser in situ keratomileusis: Risk factors. J Cataract Refract Surg 2007; 33:1530-8. [PMID: 17720066 DOI: 10.1016/j.jcrs.2007.04.043] [Citation(s) in RCA: 188] [Impact Index Per Article: 11.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2007] [Accepted: 04/25/2007] [Indexed: 11/15/2022]
Abstract
PURPOSE To examine a database of laser in situ keratomileusis (LASIK) procedures for preoperative and operative factors assumed to increase the risk for developing post-LASIK ectasia. SETTING Private clinical practice. METHODS A computer database was queried for eyes that had LASIK for myopic refractive errors with the following characteristics: preoperative corneal thickness 500 microm or less, mean keratometry greater than 47.0 diopters (D), patient age 25 years or younger, attempted correction greater than -8.0 D, refractive astigmatism not with-the-rule and greater than 2.0 D, and residual stromal bed thickness (RST) 250 microm or less. Flap thickness and RST were measured using ultrasound pachymetry. All recorded information was exported to MS Excel and analyzed for eyes that had ectasia. RESULTS Of the 9700 eyes in the database, none with the above characteristics developed ectasia over mean follow-up periods exceeding 2 years. Seven eyes had multiple risk factors without ectasia. Three eyes with abnormal preoperative topography developed ectasia. CONCLUSIONS Individual preoperative and operative factors did not in and of themselves increase the risk for ectasia. Unmeasured and unknown factors that affect the individual cornea's biomechanical stability, in combination with some suspected risk factors as well as the current inability to identify corneas at risk for developing ectatic disorders, probably account for most eyes that develop ectasia today.
Collapse
Affiliation(s)
- Perry S Binder
- Private Clinical Practice, San Diego, California 92122, USA.
| |
Collapse
|
58
|
Slade SG. The use of the femtosecond laser in the customization of corneal flaps in laser in situ keratomileusis. Curr Opin Ophthalmol 2007; 18:314-7. [PMID: 17568208 DOI: 10.1097/icu.0b013e3281bd88a0] [Citation(s) in RCA: 61] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE OF REVIEW With a growing body of work that examines the biomechanical response of the cornea following flap creation, a case has developed for creation of flaps that take advantage of the inherent strength of the stromal layers of the cornea. These flaps are thinner (+/-100 microm) and the diameter is based on the maximum ablation zone of the excimer laser. The critical component in this approach is the use of the IntraLase Femtosecond Laser (IntraLase, Irvine, California, USA) as it is the only keratome currently capable of achieving a customized flap. RECENT FINDINGS Concern over the thickness of the corneal flap has led to a resurgence of surface ablation in order to preserve as much corneal tissue as possible. Although surface ablation does offer a higher degree of safety versus laser in situ keratomileusis (LASIK), it does not achieve the same visual results during early postoperative recovery or a high degree of patient satisfaction. New biomechanical studies comparing corneal response to various types of laser refractive procedures demonstrate that corneal flaps created with a femtosecond laser are the most stable. SUMMARY This review is intended to summarize the primary advantages of a customized corneal flap in LASIK, as well as to review the biomechanics that support this approach.
Collapse
|
59
|
Binder PS, Rosenshein J. Retrospective comparison of 3 laser platforms to correct myopic spheres and spherocylinders using conventional and wavefront-guided treatments. J Cataract Refract Surg 2007; 33:1158-76. [PMID: 17586371 DOI: 10.1016/j.jcrs.2007.03.040] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2006] [Accepted: 03/26/2007] [Indexed: 10/23/2022]
Abstract
PURPOSE To compare 3 excimer laser platforms for the correction of myopic spheres and myopic spherocylinders using conventional algorithms or wavefront-guided treatments. SETTING Private practice, in-office laser facility. METHODS This retrospective comparative interventional case series comprised 458 patients (721 eyes). Sequentially selected patient eyes had laser in situ keratomileusis surgery by the same surgeon using 1 of 3 lasers (Visx Star S4, LADARVision 4000, WaveLight Allegretto) with a conventional algorithm or with wavefront-guided software. The same aberrometer was used before and after surgery in a given eye. A femtosecond laser (IntraLase Corp.) was used for flap creation. Parametric and nonparametric 1-way analysis of variance and regression analysis were performed. Outcomes were analyzed for change in visual, refractive, and wavefront categories. RESULTS On average, all lasers improved uncorrected visual acuity and best spectacle-corrected visual acuity, produced predictable refractive change, and induced higher-order aberrations (HOAs). Overall, the Star S4 wavefront treatment improved results compared with Star S4 conventional treatment; however, LADARVision wavefront treatment did not improve the conventional results. The Allegretto produced the best results in the category of visual acuity in spherocylinder eyes only. The Star S4 wavefront treatment produced the best HOA results for sphere and spherocylinder. In the spherocylinder group, the LADARVision reduced astigmatism and defocus the most. CONCLUSION These results document that different laser platforms achieve statistically significantly different outcomes depending on refractive, patient, and surgical variables.
Collapse
Affiliation(s)
- Perry S Binder
- Department of Medical Physics, Oakland University, Rochester, USA.
| | | |
Collapse
|
60
|
Huhtala A, Pietilä J, Mäkinen P, Suominen S, Seppänen M, Uusitalo H. Corneal flap thickness with the Moria M2 single-use head 90 microkeratome. ACTA ACUST UNITED AC 2007; 85:401-6. [PMID: 17559465 DOI: 10.1111/j.1600-0420.2006.00838.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
PURPOSE To analyse the accuracy of corneal flap thickness created in laser-assisted in situ keratomileusis (LASIK) using the Moria Model 2 (M2) single-use head 90 microkeratome. METHODS The corneal thickness of 300 (266 myopic and 34 hyperopic) eyes of 150 patients was measured by ultrasonic pachymetry preoperationally and intraoperationally after flap cut. The Moria M2 single-use head 90, intended to create a flap with a thickness of 120 microm, was used in all eyes. The right eye was always operated first and the left eye second, using the same blade. RESULTS Mean corneal flap thickness was 115.4 microm (standard deviation [SD] 12.5) in the two eyes, 115.7 microm (SD 12.4, range 73-147 microm) in right eyes and 115.1 microm (SD 12.6, range 74-144 microm) in left eyes. Mean horizontal flap diameter was 9.1 mm (SD 0.2) and mean hinge length 4.1 mm (SD 0.1). There were no free flaps, incomplete flaps or flaps with buttonholes in the study. Occasional iron particles were observed in three (1.0%) eyes. CONCLUSIONS As with most microkeratomes, the single-use head 90 microkeratome cut thinner flaps than were intended. The range of the cuts was relatively wide. However, thin flaps did not increase the rate of flap-related complications. The difference between the first and second eyes was not significant.
Collapse
Affiliation(s)
- Anne Huhtala
- Mehiläinen Eye Surgery Clinic, Tampere, Finland.
| | | | | | | | | | | |
Collapse
|
61
|
Patel SV, Erie JC, McLaren JW, Bourne WM. Confocal Microscopy Changes in Epithelial and Stromal Thickness up to 7 Years After LASIK and Photorefractive Keratectomy for Myopia. J Refract Surg 2007; 23:385-92. [PMID: 17455834 DOI: 10.3928/1081-597x-20070401-11] [Citation(s) in RCA: 62] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To determine the long-term changes in epithelial, stromal, and corneal thickness after LASIK and photorefractive keratectomy (PRK). METHODS In two prospective observational case series, 11 patients (16 eyes) received LASIK and 12 patients (18 eyes) received PRK to correct myopia or myopic astigmatism. None of the corneas had retreatment procedures. Corneas were examined using confocal microscopy before and at 1 month, and at 1, 2, 3, 5, and 7 years after surgery. Central thicknesses were measured from reflected light intensity profiles recorded by confocal microscopy. Postoperative epithelial thickness was compared to preoperative, and postoperative stromal and corneal thicknesses were compared to thickness at 1 month after surgery. RESULTS In LASIK, epithelial thickness at 1 month (51 +/- 4 microm, n = 11) was greater than before surgery (41 +/- 4 microm, n = 16; P < .001) and remained thicker through 7 years (52 +/- 6 microm, n = 13; P < .001). Stromal and corneal thickness did not change between 1 month and 7 years after LASIK. After PRK, corneal thickness at 1 year (464 +/- 44 microm, n = 17) was greater than at 1 month (442 +/- 39 microm, n = 15; P = .001) and remained thicker at 7 years after PRK (471 +/- 45 microm, n = 17; P > .001). CONCLUSIONS The early increase in central epithelial thickness after myopic LASIK persists for at least 7 years and is probably the result of epithelial hyperplasia. Central corneal thickness increases during the first year after PRK and remains stable thereafter up to 7 years.
Collapse
Affiliation(s)
- Sanjay V Patel
- Department of Ophthalmology, Mayo Clinic College of Medicine, Rochester, Minn., USA.
| | | | | | | |
Collapse
|
62
|
Condon PI, O'Keefe M, Binder PS. Long-term results of laser in situ keratomileusis for high myopia: Risk for ectasia. J Cataract Refract Surg 2007; 33:583-90. [PMID: 17397729 DOI: 10.1016/j.jcrs.2006.12.015] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2006] [Accepted: 12/21/2006] [Indexed: 10/23/2022]
Abstract
PURPOSE To ascertain the long-term stability of laser in situ keratomileusis (LASIK) in highly myopic eyes. SETTING Clinical practice office-based surgery. METHOD Charts of eyes with high myopia who had LASIK surgery by the same surgeon between 1994 and 2000 were reviewed in 2003, and patients were given an appointment for follow-up examinations. In these highly myopic eyes, surgery was originally performed to create undercorrections with or without decreasing the ablation diameters to maximally conserve the residual stromal bed thickness. RESULTS Of the 107 eyes with myopia between -10.00 diopters (D) and -35.00 D reviewed and operated on in a 3-year period between 1994 and 1998, 35 eyes of 31 patients had a single enhancement procedure. One case of ectasia as a result of excessive tissue removal occurred in a patient with a preoperative refraction of -28.00 D. Of the 107 eyes reviewed, 78 (73%) were examined after 5 years, 68 (63%) after 7 years, and 15 (14%) between 9 years and 11 years. CONCLUSIONS Operating on eyes with highly myopic refractive errors and removing substantial tissue thickness did not produce ectasia in this series. Although high myopia has been considered a risk factor for post-LASIK ectasia, adherence to proper screening and intraoperative pachymetry appears to decrease the risk.
Collapse
|
63
|
Sarayba MA, Ignacio TS, Tran DB, Binder PS. A 60 kHz IntraLase Femtosecond Laser Creates a Smoother LASIK Stromal Bed Surface Compared to a Zyoptix XP Mechanical Microkeratome in Human Donor Eyes. J Refract Surg 2007; 23:331-7. [PMID: 17455827 DOI: 10.3928/1081-597x-20070401-04] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To compare the stromal surfaces created by the latest mechanical microkeratome and femtosecond, laser technologies. METHODS Laser in situ keratomileusis (LASIK) flaps were created in six fresh human globes unsuitable for transplantation. The eyes were placed in one of two groups of three globes each. One group had LASIK flaps created with a Zyoptix XP microkeratome using a 120-microm head and a fresh blade for each eye. Another group had flaps created at an attempted 100-microm thickness using the 60 kHz IntraLase femtosecond laser. Immediately following flap creation, the stromal beds were prepared for scanning electron microscopy (SEM). Qualitative roughness of the SEM images was graded by masked observers. Quantitative roughness of the SEM images was assessed using computerized software designed for roughness analysis. Mann-Whitney non-parametric statistical analysis was performed to compare groups. RESULTS A statistically significant difference was noted in bed smoothness as measured by qualitative roughness and quantitative roughness scores. The IntraLase samples showed smoother stromal beds compared to the Zyoptix group (qualitative roughness = 2.0 +/- 0.7 pm vs 3.6 +/- 1.6 pm, P = .03; quantitative roughness = 20238 +/- 1869 pm vs 26368 +/- 8133 pm, P = .03). CONCLUSIONS The 60 kHz IntraLase femtosecond laser and the Zyoptix XP 120-microm head using a new blade produced smooth, good quality, compact stromal beds qualitatively and quantitatively. Because the 60 kHz femtosecond laser permits a tight spot/line separation using low energy, it creates a smoother corneal stromal bed compared to previous femtosecond laser engines.
Collapse
|
64
|
Patel SV, Maguire LJ, McLaren JW, Hodge DO, Bourne WM. Femtosecond laser versus mechanical microkeratome for LASIK: a randomized controlled study. Ophthalmology 2007; 114:1482-90. [PMID: 17350688 DOI: 10.1016/j.ophtha.2006.10.057] [Citation(s) in RCA: 107] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2006] [Revised: 10/19/2006] [Accepted: 10/22/2006] [Indexed: 11/27/2022] Open
Abstract
PURPOSE To compare corneal haze (backscattered light) and visual outcomes between fellow eyes randomized to LASIK with the flap created by a femtosecond laser (bladeless) or with the flap created by a mechanical microkeratome. DESIGN Randomized, controlled, paired-eye study. PARTICIPANTS Twenty-one patients (42 eyes) received LASIK for myopia or myopic astigmatism. METHODS One eye of each patient was randomized to flap creation with a femtosecond laser (IntraLase FS, IntraLase Corp., Irvine, CA) with intended thickness of 120 microm, and the fellow eye to flap creation with a mechanical microkeratome (Hansatome, Bausch & Lomb, Rochester, NY) with intended thickness of 180 microm. Patients were examined before and at 1, 3, and 6 months after LASIK. MAIN OUTCOME MEASURES Corneal backscatter, high-contrast visual acuity, manifest refractive error, contrast sensitivity, and intraocular forward light scatter were measured at each examination. Flap thickness was measured by confocal microscopy at 1 month, and patients were asked if they preferred the vision in either eye at 3 months. RESULTS Corneal backscatter was 6% higher after bladeless LASIK than after LASIK with the mechanical microkeratome at 1 month (P = 0.007), but not at 3 or 6 months. High-contrast visual acuity, contrast sensitivity, and forward light scatter did not differ between treatments at any examination. Flap thicknesses at 1 month were 143+/-16 microm (bladeless, mean +/- standard deviation) and 138+/-22 microm (mechanical microkeratome), with no statistical difference in variances. At 3 months, 5 patients preferred the bladeless eye, 7 patients preferred the microkeratome eye, and 9 patients had no preference. CONCLUSIONS The method of flap creation did not affect visual outcomes during the first 6 months after LASIK. Although corneal backscatter was greater early after bladeless LASIK than LASIK with the mechanical microkeratome, patients did not perceive a difference in vision.
Collapse
Affiliation(s)
- Sanjay V Patel
- Department of Ophthalmology, Mayo Clinic College of Medicine, Rochester, Minnesota, USA.
| | | | | | | | | |
Collapse
|
65
|
Abstract
To analyze the actual corneal flap thickness (FT) after flap making by MK-2000 microkeratome during laser in situ keratomileusis (LASIK), 42 females and 20 males with myopia or myopic astigmatism were enrolled in this study. FTs were created using a microkeratome with a 130 microm head. Corneal thickness was measured by ultrasonic pachymeter. The correlations between FT and central corneal thickness (CCT), keratometric power and age were analyzed. The mean age at operation for all study subjects was 27.6+/-4.9 years. The average FT was 133.2+/-15.4 microm. The average CCT was 540.+/-30.3 microm. The average keratometric power was 43.66+/-1.32 D. There was a positive correlation between FT and CCT and no correlation between FT and keratometric power or between FT and age. We recommend that LASIK surgeons inspect the actual FT when using microkeratome.
Collapse
Affiliation(s)
- Sheng-Yao Hsu
- Department of Ophthalmology, Buddhist Tzu Chi General Hospital and Tzu Chi University, Hualien, Taiwan.
| |
Collapse
|
66
|
Aslanides IM, Tsiklis NS, Astyrakakis NI, Pallikaris IG, Jankov MR. LASIK Flap Characteristics Using the Moria M2 Microkeratome With the 90-µm Single Use Head. J Refract Surg 2007; 23:45-9. [PMID: 17269243 DOI: 10.3928/1081-597x-20070101-08] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the accuracy and consistency of corneal flap thickness, horizontal diameter, and hinge size with the Moria M2 90-microm single use head. METHODS Fifty-two myopic patients (104 eyes), mean age 32.6 years, underwent bilateral LASIK with a superior hinged flap using the Moria M2 microkeratome (90-microm single use head). Prospective evaluation included flap thickness (subtraction method), diameter, hinge size, interface particles, intraoperative complications, and visual recovery. RESULTS The mean preoperative spherical equivalent refraction was -5.72 +/- 2.59 diopters (D) (range: -2.88 to -10.75 D) and -5.84 +/- 2.73 D (range: -3.13 to -9.38 D) for right and left eyes, respectively. The mean preoperative central corneal thickness was 548 +/- 24 microm and 547 +/- 25 microm for right and left eyes, respectively. The mean preoperative steepest K was 44.12 +/- 1.28 D and 44.41 +/- 1.27 D for right and left eyes, respectively. Corneal diameter (white-to-white) was 12 +/- 0.4 mm and 11.9 +/- 0.4 mm for right and left eyes, respectively. The mean postoperative flap thickness was 109 +/- 18 microm (range: 67 to 152 microm) and 103 +/- 15 microm (range: 65 to 151 microm) for right and left eyes, respectively. The mean postoperative flap diameter was 9.4 +/- 0.3 mm (expected mean according to the nomogram given by the company was 9.5 mm). The mean postoperative hinge chord was 4.4 +/- 0.4 mm (expected mean 4.2 mm). No interface particles were detected on slit-lamp examination. CONCLUSIONS The Moria M2 90-microm single use head is safe with reasonable predictability for LASIK flap creation.
Collapse
Affiliation(s)
- Ioannis M Aslanides
- VEIC - Vardinoyannion Eye Institute of Crete, School of Medicine, University of Crete, Greece
| | | | | | | | | |
Collapse
|
67
|
Choi YS, Jung HJ, Lee KH. Comparison of Clinical Result of LASIK using between Femtosecond Laser and Microkeratome for Correction of Myopia. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2007. [DOI: 10.3341/jkos.2007.48.8.1041-1047] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
68
|
Kim HJ, Oh SH, Lee DH, Lee JH, Rhee KI, Kim JH. Reproducibility of IntraLASIK Flap Thickness Measured with Optical Coherence Tomography. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2007. [DOI: 10.3341/jkos.2007.48.12.1630] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Hee Jung Kim
- Department of Ophthalmology, Ilsan Paik Hospital, Inje University College of Medicine, Gyeonggi, Korea
| | - Sae Hoon Oh
- Department of Ophthalmology, Ilsan Paik Hospital, Inje University College of Medicine, Gyeonggi, Korea
| | - Do Hyung Lee
- Department of Ophthalmology, Ilsan Paik Hospital, Inje University College of Medicine, Gyeonggi, Korea
| | - Jong Hyun Lee
- Department of Ophthalmology, Ilsan Paik Hospital, Inje University College of Medicine, Gyeonggi, Korea
| | | | - Jin Hyoung Kim
- Department of Ophthalmology, Ilsan Paik Hospital, Inje University College of Medicine, Gyeonggi, Korea
| |
Collapse
|
69
|
Condon PI. 2005 ESCRS Ridley Medal Lecture. J Cataract Refract Surg 2006; 32:2124-32. [PMID: 17137995 DOI: 10.1016/j.jcrs.2006.07.036] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2005] [Accepted: 07/11/2006] [Indexed: 11/22/2022]
Abstract
The literature on keratoconus and progressive post-laser in situ keratomileusis ectasia (PPLK) was studied after a retrospective review of 137 highly myopic eyes (mean -15.58 diopters) 5 to 9 years after LASIK. Only 2 eyes developed keratectasia, 1 after automated lamellar keratolasty for myopia and 1 after myopic LASIK. In neither case was intraoperative pachymetry carried out. In the PPLK case, a residual stromal bed thickness (RSBT) of 120 microm was discovered when a retreatment was attempted on lifting the flap. The PPLK developed 2 years later. The obvious discrepancy between reported cases of PPLK and the expected rate from the incidences in larger retrospective studies and our own 15-year experience suggests that PPLK is not a significant complication provided the standard rules applying to the preoperative total corneal thickness and RSBT are observed. However, newer techniques for the study of posterior corneal changes and those involving corneal biomechanics should be used in the future to study the long-term effects of LASIK on the cornea.
Collapse
|
70
|
Reinstein DZ, Srivannaboon S, Archer TJ, Silverman RH, Sutton H, Coleman DJ. Probability Model of the Inaccuracy of Residual Stromal Thickness Prediction to Reduce the Risk of Ectasia After LASIK Part I: Quantifying Individual Risk. J Refract Surg 2006; 22:851-60. [PMID: 17124879 DOI: 10.3928/1081-597x-20061101-04] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To measure the imprecision of microkeratome cuts, preoperative corneal pachymetry, and laser ablation depth and develop a statistical model to describe the probability of the residual stromal bed thickness (RST) after myopic LASIK being significantly thinner than predicted. METHODS Preoperative corneal thickness, flap thickness, ablation depth, and RST were measured in 36 eyes by a prototype three-dimensional very high-frequency (VHF) 50 MHz digital ultrasound scanning device (<1.2 microm precision), precursor to the commercially available Artemis 2. All eyes had undergone LASIK with the Moria LSK-One microkeratome and the NIDEK EC-5000 excimer laser. Based on the statistically combined uncertainty (standard deviation) and bias (accuracy to intended value) of corneal thickness measurement, flap thickness, and ablation depth, a continuous probability function was devised describing the chance of obtaining an actual RST less than a specified "cut-off". The model was applied using the data collected from the cohort of eyes. The model was also applied using published flap thickness statistics on a series of microkeratomes. RESULTS Precision (standard deviation) was 0.74 microm for VHF digital ultrasound measurement of pachymetry, 30.3 microm for Moria LSK-One flap thickness, and 11.2 microm for NIDEK EC-5000 ablation depth. Assuming negligible laser ablation depth bias, the model found the probability that the actual RST will be <200 pmicromgiven a target RST of 250 microm is 7.56% with the Moria LSK-One. The model applied to published flap statistics revealed a range of probabilities of leaving <200 microm given a target RST of 250 microm from <0.01% to 33.6%. CONCLUSIONS The choice of microkeratome, laser, and pachymeter has a significant impact on the variation of the depth of keratectomy and thus on the risk of ectasia. This model together with high-precision microkeratomes, preoperative pachymetry, and knowledge of laser ablation precision would enable surgeons to determine the specific imprecision of RST prediction for individual LASIK cases and minimize the risk of ectasia.
Collapse
Affiliation(s)
- Dan Z Reinstein
- London Vision Clinic, 8 Devonshire Place, London W1G 6HP, United Kingdom.
| | | | | | | | | | | |
Collapse
|
71
|
Ambrósio R, Alonso RS, Luz A, Coca Velarde LG. Corneal-thickness spatial profile and corneal-volume distribution: Tomographic indices to detect keratoconus. J Cataract Refract Surg 2006; 32:1851-9. [PMID: 17081868 DOI: 10.1016/j.jcrs.2006.06.025] [Citation(s) in RCA: 258] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2006] [Accepted: 06/18/2006] [Indexed: 11/25/2022]
Abstract
PURPOSE To evaluate whether the corneal-thickness spatial profile and corneal-volume distribution differentiate keratoconic corneas from normal corneas using new tomography parameters. SETTING Subspecialty cornea and refractive practice, Fluminense Federal University, Rio de Janeiro, Brazil. METHODS Forty-six eyes diagnosed with mild to moderate keratoconus and 364 normal eyes were studied by the Pentacam Comprehensive Eye Scanner. Corneal thickness at the thinnest point and the averages of the points on 22 imaginary circles centered on the thinnest point with increased diameters at 0.4 mm steps were calculated to create a corneal-thickness spatial profile. Corneal volume was calculated within diameters from 1.0 to 7.0 mm with 0.5 mm steps centered on the thinnest point to create the corneal-volume distribution. The percentage increase in thickness and the percentage increase in volume were calculated for each position of the corneal-thickness spatial profile and corneal-volume distribution from their first value. Statistical analysis was done using the Wilcoxon 2-independent-sample test to compare mean levels using S-Plus-4.0 software (MathSoft) and a normal linear model under a Bayesian frame for estimating the mean variation in thickness and volume using the BUGS 0.6 package. RESULTS Statistically significant differences were observed between the groups (P<.05) in all positions of corneal-thickness spatial profile and corneal-volume distribution and in the percentage increase in thickness and percentage increase in volume between 3.5 mm and 7.0 mm diameters. CONCLUSIONS Corneal-thickness spatial profile, corneal-volume distribution, percentage increase in thickness, and percentage increase in volume were different between keratoconic corneas and normal corneas and could serve as indices to diagnose keratoconus and screen refractive candidates. Further studies are necessary to evaluate whether these tomographic indices are more sensitive and specific than the classic Placido-based topography.
Collapse
|
72
|
Reinstein DZ, Srivannaboon S, Archer TJ, Silverman RH, Sutton H, Coleman DJ. Probability Model of the Inaccuracy of Residual Stromal Thickness Prediction to Reduce the Risk of Ectasia After LASIK Part II: Quantifying Population Risk. J Refract Surg 2006; 22:861-70. [PMID: 17124880 DOI: 10.3928/1081-597x-20061101-05] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To derive a statistical model to estimate the rate of excessive keratectomy depth below a selected cut-off residual stromal thickness (RST) given a minimum target RST and specific Clinical Protocol; apply the model to estimate the RST below which ectasia appears likely to occur and back-calculate the safe minimum target RST that should be used given a specific Clinical Protocol. METHODS Myopia and corneal thickness distribution were modeled for a population of 5212 eyes that underwent LASIK. The probability distribution of predicted target RST error (Part I) was used to calculate the rate of excessive keratectomy depth for this series. All treatments were performed using the same Clinical Protocol; one surgeon, Moria LSK-One microkeratome, NIDEK EC-5000 excimer laser, Orbscan pachymetry, and a minimum target RST of 250 microm--the Vancouver Clinical Protocol. The model estimated the RST below which ectasia appears likely to occur and back-calculated the safe minimum target RST. These values were recalculated for a series of microkeratomes using published flap thickness statistics as well as for the Clinical Protocol of one of the authors-the London Clinical Protocol. RESULTS In the series of 5212 eyes, 6 (0.12%) cases of ectasia occurred. The model predicted an RST of 191 microm for ectasia to occur and that a minimum target RST of 329 microm would have reduced the -rate of ectasia to 1: 1,000,000 for the Vancouver Clinical Protocol. The model predicted that the choice of microkeratome varied the rate of ectasia between 0.01 and 11,623 eyes per million and the safe minimum target RST between 220 and 361 microm. The model predicted the rate of ectasia would have been 0.000003: 1,000,000 had the London Clinical Protocol been used for the Vancouver case series. CONCLUSIONS There appears to be no universally safe minimum target RST to assess suitability for LASIK largely due to the disparity in accuracy and reproducibility of microkeratome flap thickness. This model may be used as a tool to evaluate the risk of ectasia due to excessive keratectomy depth and help determine the minimum target RST given a particular Clinical Protocol.
Collapse
Affiliation(s)
- Dan Z Reinstein
- London Vision Clinic, 8 Devonshire Place, London W1G 6HP, United Kingdom.
| | | | | | | | | | | |
Collapse
|
73
|
Abstract
PURPOSE OF REVIEW The aim of this article is to review the causes, risk factors, management, and future research directions for corneal ectasia after laser in situ keratomileusis. RECENT FINDINGS Complex corneal biomechanical processes influence the integrity of the normal and postoperative cornea, and developing an understanding of these processes facilitates recognition of risk factors for ectasia after laser in-situ keratomileusis. Currently identified risk factors include keratoconus, high myopia, low residual stromal bed thickness from excessive ablation or thick flap creation, and defined topographic abnormalities such as forme fruste keratoconus and pellucid marginal corneal degeneration. Ectasia can also rarely occur in patients without currently identifiable risk factors, and future identification of at-risk patients may be facilitated by corneal interferometry and corneal hysteresis measurements. Utilization of intraoperative pachymetry measurements at the time of surgery and confocal microscopy prior to enhancement to measure residual stromal bed thickness should avoid unanticipated low residual stromal bed thickness. Management options for ectasia after laser in situ keratomileusis include intraocular pressure reduction, rigid gas permeable contact lenses, and intracorneal ring segments, in addition to corneal transplantation. In the future, collagen cross-linking may reduce corneal steepening and improve refractive error. SUMMARY When ectasia develops, early recognition and proper management are essential to prevent progression, to promote visual rehabilitation, and to reduce the need for corneal transplantation for these patients.
Collapse
Affiliation(s)
- J Bradley Randleman
- Emory University Department of Ophthalmology and Emory Vision, Atlanta, Georgia 30322, USA.
| |
Collapse
|
74
|
Flanagan GW, Binder PS. Role of flap thickness in laser in situ keratomileusis enhancement for refractive undercorrection. J Cataract Refract Surg 2006; 32:1129-41. [PMID: 16857499 DOI: 10.1016/j.jcrs.2006.01.095] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2005] [Accepted: 01/13/2006] [Indexed: 10/24/2022]
Abstract
PURPOSE To determine which preoperative and/or perioperative factors determine the need for an enhancement for refractive undercorrection in laser in situ keratomileusis (LASIK) for spherical or spherocylindrical myopia. SETTING Clinical refractive surgery outpatient facility. METHODS In this nested case-control study within a retrospective cohort, 3850 of the 9777 eyes operated on between January 1996 and August 2005 who met the selection criteria were studied. Only patients whose refractive goal was plano were included. Control eyes were those whose latest spherical equivalent (SE) refraction was within +/-0.37 diopters (D) of emmetropia. Cases were defined as enhancements for undercorrection with an SE refraction worse than or equal to -0.50 D performed less than 6 months following the primary surgery. RESULTS Factors associated with enhancement included increasing patient age (odds ratio [OR] = 1.048, P<.001), decreasing follow-up time (OR = 0.994, P<.001), increasing minus laser sphere (OR = 0.700, P<.001) and cylinder settings (OR = 0.718, P<.001), female sex (OR = 1.112, P = .046), and corneal toricity (OR = 1.237, P = .012). The Summit laser had a significant risk for enhancement (OR = 1.726, P<.001) compared with the Visx laser, whereas the Wavelight Allegretto had a lowered risk (OR = 0.630, P = .049). Enhancement risk with the Autonomous was no different from that with the Visx (OR = 1.120, P = .342). Increasing flap thickness (OR = 1.009, P<.001) was more strongly associated with enhancement risk than residual stromal bed thickness. CONCLUSIONS After controlling for patient age, time to follow-up or surgery, corneal cylinder, sphere and cylinder laser settings, laser manufacturer, patient sex, and corneal thickness, increasing flap thickness was found to be a more important predictor of enhancement for refractive undercorrection than residual stromal thickness.
Collapse
Affiliation(s)
- Gerald W Flanagan
- Gordon Binder and Weiss Vision Institute, San Diego, California, USA.
| | | |
Collapse
|
75
|
Binder PS. One thousand consecutive IntraLase laser in situ keratomileusis flaps. J Cataract Refract Surg 2006; 32:962-9. [PMID: 16814054 DOI: 10.1016/j.jcrs.2006.02.043] [Citation(s) in RCA: 153] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2005] [Accepted: 10/10/2005] [Indexed: 11/18/2022]
Abstract
PURPOSE To measure laser in situ keratomileusis (LASIK) flap dimensions created with the IntraLase FS (IL) laser (Intralase Corporation). SETTING Private practice, San Diego, California, USA. METHODS Consecutive LASIK flaps created with the IL were measured with subtraction ultrasound at primary and enhancement surgeries. Data were stored in Outcomes Analysis Software and analyzed using MS Excel (Microsoft Corporation) and SSPS software. RESULTS The mean achieved flap thickness exceeded the attempted by 9.4 to 34.3 mum. The standard deviation varied from +/-10.2 to +/-21.7 mum. Preoperative corneal thickness and power did not affect achieved flap thickness. Seventy-three percent of mate eye flaps were within +/-15 mum of each other for the 90 mum attempted. The same flaps measured at enhancement were thicker than the primarily measured flaps (n = 58). Diffuse lamellar keratitis and slipped flaps were eliminated with experience. There were no decentered or irregular flaps, epithelial defects, or flap perforations. CONCLUSIONS Compared with published results of mechanical microkeratomes, the IL reduced the standard deviation of flap thickness as well as the achieved range. It eliminated physical complications associated with mechanical flap creation, and the impact of preoperative pachymetry and corneal power, thereby permitting more myopia to be corrected without risking deep ablations.
Collapse
Affiliation(s)
- Perry S Binder
- Gordon Binder and Weiss Vision Institute, San Diego, California 92122, USA.
| |
Collapse
|
76
|
Klein SR, Epstein RJ, Randleman JB, Stulting RD. Corneal Ectasia After Laser In Situ Keratomileusis in Patients Without Apparent Preoperative Risk Factors. Cornea 2006; 25:388-403. [PMID: 16670474 DOI: 10.1097/01.ico.0000222479.68242.77] [Citation(s) in RCA: 176] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To evaluate patients who developed ectasia with no apparent preoperative risk factors. METHODS Potential cases of patients who developed ectasia without apparent risk factors were identified by contacting participants in the Kera-Net (n = 580), ASCRS-Net (n = 450), and ISRS/AAO ISRS-Net (n = 525) internet bulletin boards from April to October 2003. Cases were included if ectasia developed after laser in situ keratomileusis in the absence of apparent preoperative risk factors. Reported cases were excluded for the following reasons: (1) calculated residual stromal bed less than 250 microm, (2) preoperative central pachymetry less than 500 microm, (3) any keratometry reading greater than 47.2 diopters (D), (4) a calculated inferior-superior value greater than 1.4, (5) more than 2 retreatments, (6) attempted initial correction greater than -12.00 D, (7) an Orbscan II "posterior float" (if obtained) greater than 50 microm, and (8) surgical/flap complications. RESULTS A total of 27 eyes of 25 patients were submitted for consideration. Eight eyes (8 patients) met our inclusion criteria. Mean age was 27.7 years (range, 18-41 years). Preoperative manifest refraction spherical equivalent was -4.61 D (range, -2.00 to -8.00 D); steepest keratometric reading was 43.86 D (range, 42.50-46.40 D); keratometric astigmatism was 0.93 D (range, 0.25-1.90 D); and preoperative central pachymetry was 537 microm (range, 505-560 microm). The mean calculated ablation depth was 82.8 microm (range, 21-125.4 microm), and mean calculated residual stromal bed was 299.5 microm (range, 254-373 microm). Mean time to recognition of ectasia onset was 14.2 months (range, 3-27 months) postoperatively. At the time of ectasia diagnosis, the mean manifest refraction spherical equivalent was -1.23 D (range, +0.125 to -3.00) with a mean of 2.72 D (range, 0.75-4.00 D) of astigmatism. CONCLUSIONS Ectasia can occur after an otherwise uncomplicated laser in situ keratomileusis procedure, even in the absence of apparent preoperative risk factors.
Collapse
Affiliation(s)
- Shawn R Klein
- Cornea Service, Department of Ophthalmology, Rush University Medical Center, Chicago, IL 60612, USA
| | | | | | | |
Collapse
|
77
|
Pietilä J, Mäkinen P, Suominen S, Huhtala A, Uusitalo H. Bilateral Comparison of Corneal Flap Dimensions With the Moria M2 Reusable Head and Single Use Head Microkeratomes. J Refract Surg 2006; 22:354-7. [PMID: 16629066 DOI: 10.3928/1081-597x-20060401-10] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To compare the Moria (Antony, France) M2 automated microkeratome with the head 130 to a new disposable single use head to evaluate complications, accuracy, and safety of the procedure. METHODS Ninety-eight eyes of 49 consecutive patients were operated with the Moria M2 microkeratome. One eye was operated with the metallic head 130 and the other with a plastic single use head, both designed to create a 160-microm flap. Intraoperative flap dimensions were correlated to preoperative parameters and evaluated 1 month postoperatively. RESULTS With the head 130, mean thickness was 153.3 microm (standard deviation [SD] 13.3, range: 102 to 179 microm). When using a single use head, mean thickness was 148.0 microm (SD 9.8, range: 120 to 170 microm). Occasional iron particles were observed in one eye with both head types. No true epithelial ingrowth was detected in any of the eyes, but epithelial dots at the wound edge occurred in one eye, when using the head 130, but not in the eyes operated with a single use head. CONCLUSIONS On average, both head types created thinner flaps than attempted. Single use heads produced thinner flaps than the head 130. Accuracy in flap thickness in terms of standard deviation was significantly better in single use heads than in the head 130. Single use heads also had fewer microkeratome-related complications. In clinical practice, the single use head was easier to use because no assembly was required. Plastic single use heads also worked more smoothly than the metallic head 130.
Collapse
|
78
|
Eisner RA, Binder PS. Technique for measuring laser in situ keratomileusis flap thickness using the IntraLase laser. J Cataract Refract Surg 2006; 32:556-8. [PMID: 16698470 DOI: 10.1016/j.jcrs.2006.01.003] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2005] [Accepted: 07/26/2005] [Indexed: 10/24/2022]
Abstract
Measurement of laser in situ keratomileusis flap thickness is required to estimate residual bed thickness. Historically, flap thickness has been assumed, estimated based on microkeratome head labeling, guessed based on flap handling characteristics, or calculated by subtraction pachymetry. We describe a method for measuring flap thickness before actual flap elevation using the IntraLase laser.
Collapse
|
79
|
Ambrosio R, Netto MV, Wilson SE. Surgery in patients with Fuchs’. Ophthalmology 2006; 113:503; author reply 504. [PMID: 16513469 DOI: 10.1016/j.ophtha.2005.12.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2005] [Accepted: 12/11/2005] [Indexed: 11/21/2022] Open
|
80
|
Taneri S. Laser in situ keratomileusis flap thickness using the Hansatome microkeratome with zero compression heads. J Cataract Refract Surg 2006; 32:72-7. [PMID: 16516782 DOI: 10.1016/j.jcrs.2005.07.042] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/15/2005] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate predictability and possible factors affecting flap thickness in laser in situ keratomileusis (LASIK) using the Hansatome microkeratome (Bausch & Lomb Surgical) with zero compression heads. SETTING Zentrum für Refraktive Chirurgie Münster, Münster, Germany. METHODS A prospective nonrandomized comparative (self-controlled) trial analyzing flap thickness in 153 consecutive patients having LASIK using the Hansatome microkeratome with zero compression was conducted. Two hundred thirty-eight eyes that had uncomplicated primary LASIK (n = 237) or secondary LASIK (n = 1) by the same surgeon and same technique using 4 different microkeratomes of the same model were evaluated. Each keratome cut was performed with a new Accuglide (Bausch & Lomb) blade in a 160 microm (n = 89), 180 microm (n = 128), or 200 microm (n = 21) Hansatome zero compression head coupled to a 8.5 mm (n = 106) or 9.5 mm (n = 131) suction ring. Only Hansatome elements with the same serial numbers were combined. Ultrasound subtraction pachymetry was routinely used to determine intraoperative flap thickness. Flap thickness was correlated with microkeratome head dimension, suction ring size, preoperative keratometry obtained by Orbscan IIz (Bausch & Lomb), preoperative corneal thickness as obtained by ultrasound pachymetry, refractive error, and age. RESULTS Measured intraoperative flap thickness was significantly different (P<.01) from predicted flap thickness. The mean flap thickness was 97 microm +/- 18 (SD) (range 65 to 163 microm), 111 +/- 20 microm (range 61 to 177 microm), and 131 +/- 20 microm (range 89 to 162 microm) for the 160 microm, the 180 microm, and 200 microm heads, respectively. There was a good correlation between microkeratome head and corneal flap thickness. However, there was a variability between devices. There was a low correlation between baseline ultrasound pachymetry at the time of surgery and corneal flap thickness (r = .26) and a small effect of ring size. There was no correlation with keratometry, refractive error, or age. CONCLUSIONS There was a remarkable difference in the flap thickness of microkeratomes of the same make and model. This emphasizes the need to measure intraoperative flap thickness and to evaluate every microkeratome separately. Factors affecting flap thickness seem to be more device dependent than patient related; obtaining flap thickness in the first eye did not enable predictions of the flap thickness in the fellow eye.
Collapse
Affiliation(s)
- Suphi Taneri
- Augenabteilung am St. Franziskus-Hospital, Münster, Germany.
| |
Collapse
|
81
|
Kanellopoulos AJ, Pe LH, Kleiman L. Moria M2 Single Use Microkeratome Head in 100 Consecutive LASIK Procedures. J Refract Surg 2005; 21:476-9. [PMID: 16209445 DOI: 10.3928/1081-597x-20050901-09] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the safety and efficacy of the Moria M2 single use 130 microkeratome head in consecutive LASIK procedures for correction of myopia and myopic astigmatism. METHODS One hundred eyes of 55 patients underwent LASIK in which the flaps were created with the Moria M2 microkeratome using the single use 130 head and excimer laser ablation was done with the Allegretto Wave-light laser. Flap parameters measured were: thickness, diameter, hinge length, and overall quality. Preoperative uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), refraction, wavefront aberrations, and low contrast sensitivity were compared to postoperative values at 6-month follow-up. RESULTS Mean flap thickness was 145 +/- 17.5 microm, mean flap diameter was 8.5 +/- 0.40 mm, and mean hinge cord length was 4.05 +/- 0.35 mm. At 6-month follow-up, UCVA improved from 20/200 (+/-0.24) to 20/18.5 (+/-0.12) and BSCVA improved from 20/20.5 (+/-0.18) to 20/17.5 (+/-0.11). CONCLUSIONS The Moria M2 single use 130 microkeratome head appears to be safe and effective in performing LASIK procedures.
Collapse
Affiliation(s)
- A John Kanellopoulos
- Department of Ophthalmology, Manhattan Eye, Ear and Throat Hospital, New York, NY, USA.
| | | | | |
Collapse
|
82
|
Netto MV, Mohan RR, Ambrósio R, Hutcheon AEK, Zieske JD, Wilson SE. Wound healing in the cornea: a review of refractive surgery complications and new prospects for therapy. Cornea 2005; 24:509-22. [PMID: 15968154 DOI: 10.1097/01.ico.0000151544.23360.17] [Citation(s) in RCA: 279] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
PURPOSE The corneal wound healing response is of particular relevance for refractive surgical procedures since it is a major determinant of efficacy and safety. The purpose of this review is to provide an overview of the healing response in refractive surgery procedures. METHODS Literature review. RESULTS LASIK and PRK are the most common refractive procedures; however, alternative techniques, including LASEK, PRK with mitomycin C, and Epi-LASIK, have been developed in an attempt to overcome common complications. Clinical outcomes and a number of common complications are directly related to the healing process and the unpredictable nature of the associated corneal cellular response. These complications include overcorrection, undercorrection, regression, corneal stroma opacification, and many other side effects that have their roots in the biologic response to surgery. The corneal epithelium, stroma, nerves, inflammatory cells, and lacrimal glands are the main tissues and organs involved in the wound healing response to corneal surgical procedures. Complex cellular interactions mediated by cytokines and growth factors occur among the cells of the cornea, resulting in a highly variable biologic response. Among the best characterized processes are keratocyte apoptosis, keratocyte necrosis, keratocyte proliferation, migration of inflammatory cells, and myofibroblast generation. These cellular interactions are involved in extracellular matrix reorganization, stromal remodeling, wound contraction, and several other responses to surgical injury. CONCLUSIONS A better understanding of the complete cascade of events involved in the corneal wound healing process and anomalies that lead to complications is critical to improve the efficacy and safety of refractive surgical procedures. Recent advances in understanding the biologic and molecular processes that contribute to the healing response bring hope that safe and effective pharmacologic modulators of the corneal wound healing response may soon be developed.
Collapse
Affiliation(s)
- Marcelo V Netto
- The Cole Eye Institute, The Cleveland Clinic Foundation, OH 44195, USA
| | | | | | | | | | | |
Collapse
|
83
|
Chan CC, Moshegov CN. Amadeus microkeratome: experience with the first 2000 cases and lessons learned. Clin Exp Ophthalmol 2005; 33:356-9. [PMID: 16033345 DOI: 10.1111/j.1442-9071.2005.01028.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
BACKGROUND To assess the safety and efficacy of the Amadeus microkeratome and to report on lessons learnt in optimizing results from its use. METHODS A retrospective review of the flap-related complications of 2000 laser in situ keratomileusis (LASIK) procedures performed by one surgeon using the Amadeus microkeratome (AMO, Irvine, CA, USA) was conducted. One hundred consecutive cases had preoperative and intraoperative pachymetry to evaluate the relationship between flap thickness, corneal thickness and reuse of the blade. RESULTS There were 35 cases of minor epithelial defects (1.8%) and four eyes with major epithelial defects (0.2%). There were no cases of suction loss, buttonholes, or incomplete or damaged flaps. There were four free caps (0.2%). Twenty-five cases had minor wrinkles and two cases had significant folds requiring relifts. Thinner corneas resulted in thinner flaps (P < 0.0001). Reuse of the blade resulted in thinner flaps (P = 0.0001). CONCLUSION The Amadeus is a safe and reliable microkeratome. Although short, there is a learning curve with use of the instrument. Corneal thickness and reuse of the blade affect flap thickness.
Collapse
Affiliation(s)
- Colin Ck Chan
- Department of Ophthalmology, Concord Hospital, Sydney, New South Wales, Australia
| | | |
Collapse
|
84
|
Cobo-Soriano R, Calvo MA, Beltrán J, Llovet FL, Baviera J. Thin flap laser in situ keratomileusis: analysis of contrast sensitivity, visual, and refractive outcomes. J Cataract Refract Surg 2005; 31:1357-65. [PMID: 16105607 DOI: 10.1016/j.jcrs.2004.12.058] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/22/2004] [Indexed: 11/30/2022]
Abstract
PURPOSE To analyze refractive, visual, and contrast sensitivity outcomes of laser in situ keratomileusis (LASIK) performed under thin flaps (less than 100 microm), and compare them with those of conventional thicker flaps. SETTING Clínica Baviera, Instituto Oftalmológico Europeo, Madrid, Spain. METHODS This retrospective study comprised 280 consecutive eyes that had LASIK for myopia using the Moria LSK-One microkeratome and the Technolas 217C excimer laser. Efficacy, predictability, and contrast sensitivity indicators were compared between 3 groups of flap thickness: thin (<100 microm, n = 105), medium (100 to 129 microm, n = 122), and thick (>130 microm, n = 53). RESULTS Refractive results were excellent and comparable between the 3 groups; however, visual outcomes-measured as efficacy, postoperative evolution of uncorrected visual acuity, and contrast sensitivity-test were significantly better in the thin flap group. Efficacy results were 92.9%, 91.0%, and 81.0% in the thin, medium, and thick flap groups, respectively (P < .05), and the rate of enhancements was 0%, 2.3%, and 5.6%, respectively. With regard to contrast sensitivity, changes between preoperative and postoperative values at month 3 of follow-up, the thin flap group achieved the preoperative levels at 3 spatial frequencies (3, 6, and 18 cycles per degree), while the thicker flap groups maintained lower than preoperative levels at more than 2 spatial frequencies. When comparing contrast sensitivity values between the 3 groups, the thin flap group also obtained the best results at lower spatial frequencies. CONCLUSIONS Thin flap LASIK is a safe technique to correct myopic defects since it blends the advantages of surface and lamellar procedures (minimal debilitation of corneal biomechanical architecture with the rapid and comfortable visual recovery of lamellar approaches). Moreover, it achieves excellent refractive outcomes, a lower rate of enhancements, and a good visual performance with better contrast sensitivity test results.
Collapse
|
85
|
Pietilä J, Mäkinen P, Suominen S, Huhtala A, Uusitalo H. Corneal Flap Measurements in Laser in situ Keratomileusis Using the Moria M2 Automated Microkeratome. J Refract Surg 2005; 21:377-85. [PMID: 16128336 DOI: 10.3928/1081-597x-20050701-13] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate accuracy and predictability and factors that influence the dimensions of the laser in situ keratomileusis (LASIK) corneal flap created with the Moria M2 automated microkeratome (Moria SA, Antony, France). METHODS The flap thickness of 454 eyes of 243 consecutive patients was measured using subtraction ultrasonic pachymetry during LASIK with the Moria M2 microkeratome head 130 designed to create a 160-microm-thick flap. Flap dimensions were evaluated and measurements were correlated with preoperative parameters. A stepwise regression analysis was used to determine the factors that influenced actual flap thickness. RESULTS The preoperative spherical equivalent refraction of the 454 eyes ranged from -12.125 diopters (D) to +6.25 D. Patient age ranged from 18 to 57 years (mean age: 31.3 +/- 8.8 years). Mean preoperative keratometric power K1 was 44.31 +/- 1.59 D and K2 was 43.32 +/- 1.54 D. Mean preoperative central comeal thickness was 552.4 +/- 32.5 microm (range: 466 to 665 microm). With an attempted thickness of 160 microm, the Moria M2 flap thickness ranged from 77 to 209 microm (mean: 153.3 +/- 19.0 microm). Mean horizontal flap diameter was 9.2 +/- 0.2 mm and mean hinge length 4.6 +/- 0.3 mm. Increasing flap thickness was found to correlate with increasing preoperative comeal thickness, younger patient age, and flatter preoperative keratometric power K1. CONCLUSIONS Although the standard deviation of the flap thickness was relatively small, remarkable individual variation was noted. Therefore, the intraoperative calculation of the remaining stromal bed is recommended. Furthermore, the consideration of central corneal thickness, patient age, and preoperative keratometry are helpful parameters to avoid too deep ablation.
Collapse
|
86
|
Duffey RJ. Thin flap laser in situ keratomileusis: flap dimensions with the Moria LSK-One manual microkeratome using the 100-microm head. J Cataract Refract Surg 2005; 31:1159-62. [PMID: 16039490 DOI: 10.1016/j.jcrs.2004.10.056] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/22/2004] [Indexed: 10/25/2022]
Abstract
PURPOSE To determine the predictability and consistency of corneal flap thickness, flap diameter, and hinge length with the modern 100 microm head of the Moria LSK-One manual microkeratome. SETTING Private clinic, office-based practice. METHODS Forty-two consecutive eyes with no previous surgery having thin flap laser in situ keratomileusis with the Moria LSK-One manual microkeratome had a new 100 microm (predicted flap thickness) head used for flap creation. Flap thickness was measured intraoperatively by subtraction ultrasound pachymetry (difference between central corneal thickness before flap cutting and residual stromal bed thickness after flap lifting). Vertical flap diameter and nasal hinge length were measured with calipers. RESULTS Mean flap thickness was 107 microm +/- 14 (SD) (range 82 to 137 microm). Standard deviation for mean vertical flap diameter was +/-0.24 mm. The cord length of the nasal hinge was variable with a mean of 4.26 +/- 0.63 mm (range 3.12 to 5.75 mm) in length. Postoperatively, there were no slipped flaps, flap striae, diffuse lamellar keratitis, or epithelial defects; there was 1 epithelial slide. At 1 day, the visual acuity was 20/20 or better in 76% of eyes. CONCLUSIONS The 100 microm head of the Moria LSK-One manual microkeratome cut a very predictable flap thickness and diameter but with variable length hinges. This flap thickness predictability was superior to that in other series with thicker intended flaps cut with mechanical microkeratomes and is comparable to that reported with the IntraLase FS femtosecond laser. Visual recovery was rapid, epithelial risks minimal, efficiency superior, and cost nominal relative to femtosecond laser technology.
Collapse
|
87
|
Choudhri SA, Feigenbaum SK, Pepose JS. Factors Predictive of LASIK Flap Thickness With the Hansatome Zero Compression Microkeratome. J Refract Surg 2005; 21:253-9. [PMID: 15977882 DOI: 10.3928/1081-597x-20050501-08] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To determine the explanatory power of preoperative variables and comeal flap thickness in laser in situ keratomileusis (LASIK) using the Hansatome zero compression microkeratome (Bausch & Lomb, Rochester, NY). METHODS A prospective, nonrandomized, comparative interventional case study was performed on 250 eyes of 129 consecutive patients who underwent LASIK surgery using the Hansatome zero compression microkeratome. A 160-microm or 180-microm microkeratome head and an 8.5- or 9.5-mm suction ring were used in the procedures. Preoperative measurements included refraction, spherical equivalent, keratometry, intraocular pressure, corneal white-to-white, anterior chamber depth, and corneal eccentricity. Corneal thickness was measured intraoperatively using ultrasonic pachymetry before and after flap creation, and the difference was taken as flap thickness. Flap diameter was measured with a corneal gauge. Data were analyzed using simple, multiple, stepwise linear and non-linear regression analyses and two-tailed t tests. RESULTS The mean flap thickness was 124 +/- 17 microm with the nominal 160-microm head and 142 +/- 20 microm with the nominal 180-microm head. One third (33%) of the total variation in flap thickness could be accounted for by three preoperative variables: average corneal thickness, spherical equivalent refraction, and choice of 160- or 180-microm microkeratome head. A simple correlation of 0.114 was noted between corneal eccentricity and flap thickness, but this variable did not add significant explanatory power on multiple regression analysis. Linear regression analysis allowed determination of a flap thickness nomogram with a standard error of the estimate of 16.9 microm and a 95% confidence interval of +/- 33.1. CONCLUSIONS Comeal thickness is the most systematic predictor of corneal flap thickness using the Hansatome microkeratome. Because three preoperative variables account for only 33% of the range in flap thickness, future studies should focus on variations in blade extension and corneal biomechanical factors, which may also play an important role in determining flap thickness.
Collapse
|
88
|
Touboul D, Salin F, Mortemousque B, Chabassier P, Mottay E, Léger F, Colin J. Avantages et inconvénients du microkératome laser femtoseconde. J Fr Ophtalmol 2005; 28:535-46. [PMID: 15976724 DOI: 10.1016/s0181-5512(05)81094-0] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
Laser in situ keratomileusis (LASIK) complications are mainly attributable to imperfect cutting with the mechanical microkeratome. The femtosecond laser is an important challenger because it can provide extremely precise cutting beginning at any corneal point. We analyze the potential of this new tool from the results reported in the literature. The optomechanical control of the impact position provides freer and more effective intrastromal cutting than the blade. The best cutting matrix is obtained with the postage stamp method. If the plasma quality is not perfectly under control, side effects such as tissue streaks and secondary ultraviolet radiations can be observed. For LASIK surgery, femtolaser cutting can offer greater safety, reproducibility, predictability and flexibility. The risk of incomplete or irregular cutting and the free cap risk are reduced. Striae, epithelial defects and interface deposits should be minimized. A better flap congruence can limit the risk of secondary displacement and epithelial ingrowth. The results of making thinner flaps should be more predictable. Other than the high cost of the procedure, laser cutting has very few disadvantages. In 1999, Intralase Corporation introduced the first femtolaser microkeratome on the American market. Approximately 120,000 intra-LASIK procedures have been carried out with fewer cutting complications than with the mechanic blade.
Collapse
Affiliation(s)
- D Touboul
- Service d'ophtamologie du CHU de Bordeaux, Université Bordeaux 2, France.
| | | | | | | | | | | | | |
Collapse
|
89
|
Guirao A. Theoretical Elastic Response of the Cornea to Refractive Surgery: Risk Factors for Keratectasia. J Refract Surg 2005; 21:176-85. [PMID: 15796224 DOI: 10.3928/1081-597x-20050301-14] [Citation(s) in RCA: 97] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To explore the role that mechanical elastic factors may have in post-refractive surgery corneal phenomena, from mild curvature changes to keratectasia. METHODS The central cornea near the apex was modeled as an elastic spherical thin shell loaded by the intraocular pressure (IOP). Equations for myopic laser in situ keratomileusis (LASIK) were obtained to estimate shifts and curvature changes of the posterior corneal surface at the apex. The effect of every parameter was studied, identifying potential risk factors for ectasia. RESULTS Theoretically, corneal thinning by ablation will produce an elastic deformation of the posterior surface that depends on the corneal parameters (curvature, Young's modulus, Poisson ratio, and thickness), the IOP, and the ablation profile. In particular, a forward shift and an increase in power of the posterior surface was predicted for myopic LASIK, in agreement with previous experimental findings. These changes rise non-linearly with the attempted correction, and are greater for thinner preoperative corneas, higher IOP smaller Young's modulus, and thicker flaps. Corneas with Young's modulus half the average or less, or thickness <500 microm, may present high risk of ectasia, especially for high IOP and thick flaps. CONCLUSIONS Some postoperative effects may be explained in part by elasticity. Research efforts are needed to explain other biomechanical behaviors. The accepted criterion of 250 microm residual bed is insufficient for fine patient screening--depending on the individual ocular parameters, it could be more restrictive. Advances in technology are needed to create a preoperative examination including two-dimensional maps of topography, pachymetry, and Young's modulus.
Collapse
|
90
|
Touboul D, Salin F, Mortemousque B, Courjaud A, Chabassier P, Mottay E, Léger F, Colin J. Effets tissulaires et mécaniques observés lors de l’expérimentation d’un microkératome laser femtoseconde pour la chirurgie réfractive cornéenne. J Fr Ophtalmol 2005; 28:274-84. [PMID: 15883492 DOI: 10.1016/s0181-5512(05)81054-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
PURPOSE Despite progress in mechanical microkeratomes used in refractive surgery, mechanical complications during cutting of the cornea still occur. Cutting by laser could reduce these complications and to date, the femtosecond laser is the only potential candidate for this purpose. Our study reports preliminary results with a femtosecond microkeratome for cutting porcine corneas ex vivo. METHODS We first examined the fundamental principles of the interaction between the femtosecond laser and the corneal stroma, including the volume of tissue lesions, the laser breakdown threshold of the stroma and the laser ablation selectivity. We then analyzed the quality of cutting corneal flaps with the laser, focusing on collateral tissue effects and the roughness of the interfaces observed both histologically and with scanning electron microscopy. RESULTS The photoablative and photodisruptive effects were very similar with the femtosecond laser. This characteristic is specific to ultrashort impulsion photodisruptor lasers and allows for a very precise surgical procedure. The laser-induced breakdown threshold of porcine corneal stroma was found to be 0.55 J/cm2. Collateral tissue lesions were on the submicrometer level. The roughness of the stromal bed was optimal for postage stamp cutting, providing very many contiguous points of impact which were as spherical as possible. CONCLUSION Corneal photodisruption with a femtosecond laser is reproducible and extremely accurate. The optomechanical parameters involved with this technique require great technological skill and should be placed in experienced hands.
Collapse
Affiliation(s)
- D Touboul
- Centre des Lasers Intenses et Applications (CELIA), Université Bordeaux-1, Bordeaux.
| | | | | | | | | | | | | | | |
Collapse
|
91
|
Nassaralla BA, McLeod SD, Boteon JE, Nassaralla JJ. The effect of hinge position and depth plate on the rate of recovery of corneal sensation following LASIK. Am J Ophthalmol 2005; 139:118-24. [PMID: 15652836 DOI: 10.1016/j.ajo.2004.08.057] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/23/2004] [Indexed: 10/25/2022]
Abstract
PURPOSE To evaluate and compare the effect of hinge position and flap thickness on recovery rate of corneal sensation after (LASIK). DESIGN Prospective, randomized clinical study. METHODS Forty eyes of 40 patients underwent LASIK to correct myopia ranging from -1.00 to -2.50 diopters. Corneal sensitivity was measured preoperatively and each month after surgery until recovery to preoperative level. The nasal-hinged ACS microkeratome (NH) with depth plates of 130 and 160 microm and the superior-hinged Hansatome microkeratome (SH) with depth plates of 160 and 180 microm were used for corneal flap creation. The eyes were divided into four groups according to the hinge position and depth plate (DP): group 1, NH and 130 microm DP; group 2, NH and 160 microm DP; group 3, SH and 160 microm DP; group 4, SH and 180 microm DP. RESULTS Corneal sensitivity returned to preoperative level after 3.7 (+/- 0.4), 4.4 (+/- 0.6), 5.4 (+/- 0.8), and 5.8 (+/- 0.9) months, respectively, in groups 1, 2, 3, and 4. Statistically significant differences were found between groups 1 and 2, but not between groups 3 and 4. Corneal sensitivity gradually returned to preoperative levels in all groups. Sensitivity of the hinge area was higher than other areas at every time point. CONCLUSIONS The results suggest that after LASIK, hinge position and flap thickness seem to be important factors in the rate of return of corneal sensitivity. A thin flap with a nasally placed hinge is associated with the most rapid recovery of corneal sensitivity.
Collapse
|
92
|
Flanagan GW, Binder PS. The Theoretical vs. Measured Laser Resection for Laser in situ Keratomileusis. J Refract Surg 2005; 21:18-27. [PMID: 15724681 DOI: 10.3928/1081-597x-20050101-07] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To measure the excimer laser resection during and after laser in situ keratomileusis (LASIK) and to determine the rate of stromal ablation and factors predicting its measurement. METHODS A retrospective, comparative, interventional case study of 6010 eyes undergoing LASIK surgery was performed. In vivo ultrasonic pachymetry was performed as a measure of the laser resection (1'MLR). The theoretical laser resection generated by one of three separate excimer lasers (Summit Apex Plus, Alcon LadarVision, VISX) was recorded. The change in central comeal thickness measured at enhancement surgery (2'MLR) and the change in the residual stromal thickness prior to the laser ablation at the primary and enhancement procedure (3'MLR) were recorded as separate measures of the laser resection. Paired sample t test and regression analysis was performed to determine the relationships and to develop a model predictive of laser resection for each laser. RESULTS For all lasers, 1'MLR produced the highest estimate compared to 3'MLR. Laser-induced stromal desiccation, microkeratome effects, and change in measured flap thickness were the most likely causes for the differences. Laser resection was overestimated in the Alcon theoretical laser resection group, but underestimated in the Summit and VISX groups. The difference between 2'MLR and 3'MLR was due to epithelial hyperplasia, which measured 8.3, 17.8, and 10.8 microm in the Alcon, Summit, and VISX enhancement groups, respectively. Stromal ablation rates were 11.79, 8.26, and 12.71 microm per spherical equivalent diopter laser setting for the Alcon, Summit, and VISX lasers, respectively, when measured with 3'MLR. Multiple pre- and perioperative factors were associated with laser resection. CONCLUSIONS To accurately predict residual corneal thickness, the expected laser resection for an attempted refractive change must be known. As the laser resection can be laser-specific, the surgeon needs to establish the mean and range of tissue removal for a given attempted correction.
Collapse
|
93
|
Versace P, Watson SL. Cornea-sparing laser in situ keratomileusis: Ablation on the flap. J Cataract Refract Surg 2005; 31:88-96. [PMID: 15721700 DOI: 10.1016/j.jcrs.2004.10.040] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/02/2004] [Indexed: 10/25/2022]
Abstract
PURPOSE To evaluate the safety and efficacy of laser ablation on the flap as a treatment for a refractive error. SETTING Laser Sight Centres, Sydney, Australia. METHODS In this noncomparative case series, 142 treatments were performed in 98 patients using cornea-sparing laser in situ keratomileusis (LASIK) with ablation of the corneal flap and, in some cases, also the stromal bed for spherical equivalent (SE) refractive errors from -0.50 diopter (D) to -12.38 D. The procedure was performed as a primary treatment in 104 eyes, an initial enhancement in 32 eyes, and a second enhancement in 6 eyes. Data were extracted for analysis by retrospective review of patients' charts. RESULTS After LASIK, the mean SE was -0.20 D +/- 0.47 (SD) (range +0.87 to -2.35 D) excluding eyes with monovision. The 6 eyes with monovision had a mean SE of -1.90 D with myopia of -1.70 D (range -1.00 to -3.00 D) and mean astigmatism of -0.37 D (range 0 to -0.75 D). Excluding eyes with monovision, 97% of eyes achieved an uncorrected visual acuity of 6/12 or better and 64% of eyes, better than or equal to 6/6. Ninety-six percent were within +/-1.0 D of the intended correction (SE). The safety index was 1.02 and the efficacy index, 0.8. CONCLUSIONS Laser ablation of the corneal flap achieved good visual results and enabled preservation of the posterior corneal stroma. This technique may aid the prevention of corneal keratectasia following LASIK.
Collapse
|
94
|
Tran DB, Sarayba MA, Bor Z, Garufis C, Duh YJ, Soltes CR, Juhasz T, Kurtz RM. Randomized prospective clinical study comparing induced aberrations with IntraLase and Hansatome flap creation in fellow eyes. J Cataract Refract Surg 2005; 31:97-105. [PMID: 15721701 DOI: 10.1016/j.jcrs.2004.10.037] [Citation(s) in RCA: 151] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/02/2004] [Indexed: 10/25/2022]
Abstract
PURPOSE To measure and compare the changes in objective wavefront aberration and subjective manifest refraction after laser in situ keratomileusis (LASIK) flap creation with a mechanical microkeratome and a femtosecond laser. SETTING Private practice refractive surgery center, Irvine, California, USA. METHODS This randomized prospective study comprised 9 patients (18 eyes) treated with a 2-step LASIK procedure: lamellar keratectomy with a Hansatome microkeratome (Bausch & Lomb) or the IntraLase femtosecond laser in fellow eyes followed by non-wavefront-guided (standard) excimer laser treatment with the Technolas 217A (Bausch & Lomb) excimer laser 10 weeks later. Fellow eyes were matched to within 0.75 diopter (D) sphere and 0.50 D cylinder. Patients were followed for 3 months after excimer laser treatment. Preoperative and post-flap creation wavefront aberrometry using a Hartmann-Shack aberrometer and manifest refraction were compared between the 2 groups. The same tests were performed 3 months after excimer laser ablation. RESULTS Statistically significant changes were seen in defocus wavefront aberrations after Hansatome (P=.004) and IntraLase (P=.008) flap creation. A hyperopic shift in manifest refraction was noted in the Hansatome group after the creation of the corneal flap (P=.04); no statistically significant changes in manifest refraction were seen in the IntraLase group. Statistically significant changes in total higher-order aberrations (HOAs) (trefoil and quadrafoil Zernike terms) were seen after flap creation in the Hansatome group (P=.02). No significant changes in HOAs were noted after flap creation in the IntraLase group. After the flap was relifted and standard excimer laser ablation was performed, a statistically significant increase in coma occurred in the Hansatome group (P=.008). Standard refractive outcomes in the 2 groups were similar. CONCLUSIONS The creation of the LASIK flap alone can modify the eye's optical characteristics in low-order aberrations and HOAs. A significant increase in HOAs was seen in the Hansatome group but not in the IntraLase group. This may have significant clinical implications in wavefront-guided LASIK treatments, which are based on measurements made before flap creation.
Collapse
Affiliation(s)
- Dan B Tran
- Coastal Vision Medical Group, Inc., University of California Irvine, Irvine, California, USA.
| | | | | | | | | | | | | | | |
Collapse
|
95
|
Fogla R, Padmanabhan P. Interrupted sutures at the hinge site to manage a free flap during laser in situ keratomileusis. J Cataract Refract Surg 2004; 30:2235-8. [PMID: 15474844 DOI: 10.1016/j.jcrs.2004.02.084] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/23/2004] [Indexed: 11/29/2022]
Abstract
Two patients developed free flaps intraoperatively during laser in situ keratomileusis. After excimer laser treatment was performed, the free flap was replaced, maintaining proper alignment. Interrupted sutures were placed superiorly at the intended hinge site to secure the free flap. The uncorrected visual acuity was 20/30 in the affected eyes of both patients after treatment. At the 6-month follow-up, there were no flap-related complications and there was no loss of best corrected visual acuity.
Collapse
Affiliation(s)
- Rajesh Fogla
- Sankara Nethralaya, Medical and Vision Research Foundations, Chennai, India.
| | | |
Collapse
|
96
|
Solomon KD, Donnenfeld E, Sandoval HP, Al Sarraf O, Kasper TJ, Holzer MP, Slate EH, Vroman DT. Flap thickness accuracy. J Cataract Refract Surg 2004; 30:964-77. [PMID: 15130631 DOI: 10.1016/j.jcrs.2004.01.023] [Citation(s) in RCA: 77] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/21/2004] [Indexed: 11/17/2022]
Abstract
PURPOSE To determine the flap thickness accuracy of 6 microkeratome models and determine factors that might affect flap thickness. SETTING Magill Research Center for Vision Correction, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. METHODS This multicenter prospective study involved 18 surgeons. Six microkeratomes were evaluated: AMO Amadeus, Bausch & Lomb Hansatome, Moria Carriazo-Barraquer, Moria M2, Nidek MK2000, and Alcon Summit Krumeich-Barraquer. Eyes of 1061 consecutive patients who had laser in situ keratomileusis were included. Age, sex, surgical order (first or second cut), keratometry (flattest, steepest, and mean), white-to-white measurement, laser used, plate thickness, head serial number, blade lot number, and occurrence of epithelial defects were recorded. Intraoperative pachymetry was obtained just before the microkeratome was placed on the eye. Residual bed pachymetry was measured after the microkeratome cut had been created and the flap lifted. The estimated flap thickness was determined by subtraction (ie, mean preoperative pachymetry measurement minus mean residual bed pachymetry). RESULTS A total of 1634 eyes were reviewed. Sex distribution was 54.3% women and 45.7% men, and the mean age was 39.4 years +/- 10.6 (SD). In addition, 54.5% of the procedures were in first eyes and 45.5%, in second eyes. The mean preoperative pachymetry measurement was 547 +/- 34 microm. The mean keratometry was 43.6 +/- 1.6 diopters (D) in the flattest axis and 44.6 +/-1.5 D in the steepest axis. The mean white-to-white measurement was 11.7 +/- 0.4 mm. The mean flap thickness created by the devices varied between head designs, and microkeratome heads had significant differences (P<.05). Factors that explained 78.4% of the variability included microkeratome model, plate thickness, mean preoperative pachymetry, Kmin, surgery order, head serial number, blade lot number, and surgeon. Factors such as age, sex, Kmax, Kaverage, white to white, and laser had no significant correlation to flap thickness. CONCLUSIONS The results demonstrated variability between the 6 microkeratome models. Device labeling did not necessarily represent the mean flap thickness obtained, nor was it uniform or consistent. Thinner corneas were associated with thinner flaps and thicker corneas with thicker flaps. In addition, first cuts were generally associated with thicker flaps when compared to second cuts in bilateral procedures.
Collapse
Affiliation(s)
- Kerry D Solomon
- Magill Research Center for Vision Correction, Storm Eye Institute, Medical University of South Carolina, Charleston, SC 29425, USA.
| | | | | | | | | | | | | | | |
Collapse
|
97
|
Abstract
Eighty-five cases of post laser in situ keratomileusis ectasia were reviewed and analyzed. Cases of keratoconus or forme fruste keratoconus were eliminated; many remaining case reports lacked key information. The current literature is unable to define a specific residual corneal thickness or a range of preoperative corneal thickness that would put an eye at risk for developing ectasia. The most logical cause for eyes without preexisting pathology to develop ectasia is a postablation stromal thickness that is mechanically unstable; this "minimal" thickness is probably specific to each eye. The preoperative and postoperative corneal thickness, measured flap thickness, and microkeratome and laser parameters used in a given case are required to determine the range of residual corneal thickness that puts the eye at risk for developing ectasia. Other as yet undetermined factors may play a role in the development of this complication.
Collapse
Affiliation(s)
- Perry S Binder
- Gordon Binder Vision Institute, San Diego, CA 92112, USA.
| |
Collapse
|
98
|
Miranda D, Smith SD, Krueger RR. Comparison of flap thickness reproducibility using microkeratomes with a second motor for advancement. Ophthalmology 2003; 110:1931-4. [PMID: 14522767 DOI: 10.1016/s0161-6420(03)00786-3] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022] Open
Abstract
PURPOSE To compare flap thickness and reproducibility of four different types of microkeratomes during LASIK. DESIGN Retrospective, nonrandomized, comparative case series. PARTICIPANTS Four hundred ninety consecutive eyes underwent LASIK and were evaluated by measuring the central flap thickness by subtractive pachymetry. METHODS All flaps were created using the Bausch & Lomb (Miami, FL) Hansatome 180 head, the Alcon (Fort Worth, TX) Summit Krumeich Barraquer Microkeratome 160 head, the Moria (Antony, France) Carriazo Barraquer (CB) 130 head, or the Moria M2 110 head. RESULTS The flap thickness measurements differed according to the microkeratome used and were 131+/-28 microm in 41 eyes (8.4%) with the Bausch & Lomb Hansatome 180 head, 162+/-21 microm in 127 eyes (25.9%) with the Alcon Summit Krumeich Barraquer Microkeratome (SKBM) 160 head, 157+/-40 microm in 65 eyes (13.3%) with the Moria CB 130 head, and 134+/-23 microm in 257 eyes (52.4%) with the Moria M2 110 head. The central flap thickness with the SKBM and Moria M2 was statistically significantly more reproducible than with the Moria CB (P< 0.0005). There is no correlation between flap thickness reproducibility and age, corneal thickness, or corneal keratometric values. However, considering all the microkeratomes, female gender had statistically significantly more variability than male gender (P<0.02). CONCLUSIONS Based on these results, the greatest predictability of flap thickness was seen with the SKBM and Moria M2 microkeratomes, which both use a second motor for advancement. The greatest variability, noted with the Moria CB, was likely due to the manual translation feature and places further importance on the safety of the second motor and automation when performing LASIK.
Collapse
Affiliation(s)
- Danielle Miranda
- Department of Refractive Surgery, Cole Eye Institute, The Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, OH 44195, USA
| | | | | |
Collapse
|