51
|
Luján-Sanchis M, Sanchis-Artero L, Larrey-Ruiz L, Peño-Muñoz L, Núñez-Martínez P, Castillo-López G, González-González L, Clemente CB, Albert Antequera C, Durá-Ayet A, Sempere-Garcia-Argüelles J. Current role of capsule endoscopy in Crohn’s disease. World J Gastrointest Endosc 2016; 8:572-583. [PMID: 27668067 PMCID: PMC5027027 DOI: 10.4253/wjge.v8.i17.572] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/13/2016] [Revised: 05/25/2016] [Accepted: 07/18/2016] [Indexed: 02/05/2023] Open
Abstract
Capsule endoscopy (CE) currently plays an important role in Crohn’s disease (CD). It is a noninvasive technique that has led to a breakthrough in the endoscopic diagnosis of diseases of the small intestine. Its superior diagnostic performance and excellent safety profile lead to its considerable acceptance on the part of the patient. This paper reviews current indications of CE in three stages of clinical practice: Suspected CD, unclassified colitis and its extensive role in diagnosed CD. The diagnostic and therapeutic impact of the results of CE on the monitoring of this disease is also reviewed. Knowledge of its applications, the interpretation of its results in an appropriate context and the existence of a validated endoscopic activity index could change the way in which these patients are managed. The definition of mucosal healing and postoperative recurrence by means of endoscopic scoring systems will endow CE with new applications in the management of CD in the near future.
Collapse
|
52
|
Deeba F, Mohammed SK, Bui FM, Wahid KA. Unsupervised abnormality detection using saliency and Retinex based color enhancement. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2016:3871-3874. [PMID: 28269131 DOI: 10.1109/embc.2016.7591573] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
An efficient and automated abnormality detection method can significantly reduce the burden of screening of the enormous visual information resulting from capsule endoscopic procedure. As a pre-processing stage, color enhancement could be useful to improve the image quality and the detection performance. Therefore, in this paper, we have proposed a two-stage automated abnormality detection algorithm. In the first stage, an adaptive color enhancement method based on Retinex theory is applied on the endoscopic images. In the second stage, an efficient salient region detection algorithm is applied to detect the clinically significant regions. The proposed algorithm is applied on a dataset containing images with diverse pathologies. The algorithm can successfully detect a significant percentage of the abnormal regions. From our experiment, it was evident that color enhancement method improves the performance of abnormality detection. The proposed algorithm can achieve a sensitivity of 97.33% and specificity of 79%, higher than state-of-the-art performance.
Collapse
|
53
|
Collins PD. Video capsule endoscopy in inflammatory bowel disease. World J Gastrointest Endosc 2016; 8:477-488. [PMID: 27499830 PMCID: PMC4959941 DOI: 10.4253/wjge.v8.i14.477] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/27/2016] [Revised: 05/01/2016] [Accepted: 06/03/2016] [Indexed: 02/06/2023] Open
Abstract
Video capsule endoscopy (VCE) has evolved to become an important tool for the non-invasive examination of the small bowel, which hitherto had been relatively inaccessible to direct visualisation. VCE has been shown to play a role in monitoring the activity of small bowel Crohn’s disease and can be used to assess the response to anti-inflammatory treatment in Crohn’s disease. For those patients with Crohn’s disease who have undergone an intestinal resection, VCE has been assessed as a tool to detect post-operative recurrence. VCE may also aid in the reclassification of patients with a diagnosis of Inflammatory Bowel Disease Unclassified to Crohn’s disease. The evolution of colon capsule endoscopy (CCE) has expanded the application of this technology further. The use of CCE to assess the activity of ulcerative colitis has been described. This advance in capsule technology has also fuelled interest in its potential role as a minimally invasive tool to assess the whole of GI tract opening the possibility of its use for the panenteric assessment of Crohn’s disease. VCE is a safe procedure. However, the risk of a retained capsule is higher in patients with suspected or confirmed Crohn’s disease compared with patients having VCE examination for other indications. A retained video capsule is rare after successful passage of a patency capsule which may be utilised to pre-screen patients undergoing VCE. This paper describes the use of VCE in the assessment of inflammatory bowel disease.
Collapse
|
54
|
Rossi RE, Conte D, Elli L, Branchi F, Massironi S. Endoscopic techniques to detect small-bowel neuroendocrine tumors: A literature review. United European Gastroenterol J 2016; 5:5-12. [PMID: 28405316 DOI: 10.1177/2050640616658220] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/25/2016] [Accepted: 06/12/2016] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND The diagnosis of small-bowel neuroendocrine tumors (SbNETs) has improved with the advent of video capsule endoscopy (CE) and double-balloon enteroscopy (DBE). The data describing the efficacy of CE/DBE in the detection of SbNETs are scanty. AIM The aim of this article is to review the current evidence on the role of DBE and CE in the diagnosis of SbNETs. MATERIAL AND METHODS A bibliographical search was performed in PubMed using the following keywords: "neuroendocrine tumors and enteroscopy/and capsule endoscopy" and "small bowel neuroendocrine tumors." RESULTS CE and DBE can be complementary and show a similar diagnostic yield. The number of false-negative results has not been established yet because of the "work-up bias" observed in the majority of the studies. CONCLUSIONS DBE and CE appear to be both safe and effective procedures useful in the diagnosis of SbNETs. Further studies are required to clarify their potential complications and relationship with other techniques, particularly nuclear imaging.
Collapse
Affiliation(s)
- Roberta Elisa Rossi
- Gastroenterology and Endoscopy Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Italy; Department of Pathophysiology and Transplantation, Università degli Studi di Milano, Italy
| | - Dario Conte
- Gastroenterology and Endoscopy Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Italy; Department of Pathophysiology and Transplantation, Università degli Studi di Milano, Italy
| | - Luca Elli
- Gastroenterology and Endoscopy Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Italy; Center for Prevention and Diagnosis of Celiac Disease, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Italy
| | - Federica Branchi
- Gastroenterology and Endoscopy Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Italy; Center for Prevention and Diagnosis of Celiac Disease, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Italy
| | - Sara Massironi
- Gastroenterology and Endoscopy Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Italy
| |
Collapse
|
55
|
Castañeda-Ortiz RA, Espinosa-Rosas P, Rodriguez-Izaguirre RA, Anzo-Osorio A, Almanza-Miranda E, Waller-Gónzalez LA, Gómez-Navarro G, Jimenez-Urueta PS. Experiencia de cápsula endoscópica en sangrado de origen obscuro y dolor abdominal crónico recurrente en Pediatría del CMN «20 de Noviembre» del ISSSTE. ENDOSCOPIA 2016. [DOI: 10.1016/j.endomx.2016.07.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
56
|
Catalano C, Companioni RAC, Khankhanian P, Vyas N, Patel I, Bansal R, Walfish A. Video capsule endoscopy: is bowel preparation necessary? J Investig Med 2016; 64:1114-7. [DOI: 10.1136/jim-2016-000153] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/19/2016] [Indexed: 01/19/2023]
Abstract
There is no standardized protocol for bowel preparation prior to video capsule endoscopy, although one is strongly recommended. The purpose of our study was to see if there was a statistical significance between small bowel mucosal visualization rates for those who received bowel preparation and those who did not. We retrospectively analyzed all patients who had a video capsule endoscopy from August 2014 to January 2016 at a tertiary care center. All patients fasted prior to the procedure. Bowel preparation when used consisted of polyethylene glycol. A long fast consisted of 12 or more hours. The grading system used to assess the small bowel was adapted from a previously validated system from Esaki et al. Statistical analyses were performed using Fisher's exact test or Welch's 2-sample t-test and statistical significance was present if the p value was ≤0.05. 76 patients were carried forward for analysis. Small bowel mucosal visualization rates were similar between those who received bowel preparation and those who did not (92.5% vs 88.9%, p=0.44). Small bowel mucosal visualization rates were significantly better in those patients who had a long fast compared with those who had a short fast (97.7% vs 81.3%, p=0.019). Our study demonstrates that the addition of bowel preparation prior to video capsule endoscopy does not significantly improve small bowel mucosal visualization rates and, in addition, there is a statistically significant relationship between increased fasting time and improved small bowel mucosal visualization. A prolonged fast without bowel preparation might be satisfactory for an adequate small bowel visualization but further randomized, prospective studies are necessary to confirm these findings.
Collapse
|
57
|
Ciuti G, Caliò R, Camboni D, Neri L, Bianchi F, Arezzo A, Koulaouzidis A, Schostek S, Stoyanov D, Oddo CM, Magnani B, Menciassi A, Morino M, Schurr MO, Dario P. Frontiers of robotic endoscopic capsules: a review. JOURNAL OF MICRO-BIO ROBOTICS 2016; 11:1-18. [PMID: 29082124 PMCID: PMC5646258 DOI: 10.1007/s12213-016-0087-x] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2016] [Revised: 03/24/2016] [Accepted: 04/07/2016] [Indexed: 12/15/2022]
Abstract
Digestive diseases are a major burden for society and healthcare systems, and with an aging population, the importance of their effective management will become critical. Healthcare systems worldwide already struggle to insure quality and affordability of healthcare delivery and this will be a significant challenge in the midterm future. Wireless capsule endoscopy (WCE), introduced in 2000 by Given Imaging Ltd., is an example of disruptive technology and represents an attractive alternative to traditional diagnostic techniques. WCE overcomes conventional endoscopy enabling inspection of the digestive system without discomfort or the need for sedation. Thus, it has the advantage of encouraging patients to undergo gastrointestinal (GI) tract examinations and of facilitating mass screening programmes. With the integration of further capabilities based on microrobotics, e.g. active locomotion and embedded therapeutic modules, WCE could become the key-technology for GI diagnosis and treatment. This review presents a research update on WCE and describes the state-of-the-art of current endoscopic devices with a focus on research-oriented robotic capsule endoscopes enabled by microsystem technologies. The article also presents a visionary perspective on WCE potential for screening, diagnostic and therapeutic endoscopic procedures.
Collapse
Affiliation(s)
- Gastone Ciuti
- The BioRobotics Institute of Scuola Superiore Sant'Anna, Pontedera, Pisa 56025 Italy
| | - R Caliò
- The BioRobotics Institute of Scuola Superiore Sant'Anna, Pontedera, Pisa 56025 Italy
| | - D Camboni
- The BioRobotics Institute of Scuola Superiore Sant'Anna, Pontedera, Pisa 56025 Italy
| | - L Neri
- The BioRobotics Institute of Scuola Superiore Sant'Anna, Pontedera, Pisa 56025 Italy.,Ekymed S.r.l., Livorno, Italy
| | - F Bianchi
- The BioRobotics Institute of Scuola Superiore Sant'Anna, Pontedera, Pisa 56025 Italy
| | - A Arezzo
- Department of Surgical Disciplines, University of Torino, Torino, Italy
| | - A Koulaouzidis
- Endoscopy Unit, The Royal Infirmary of Edinburgh, Edinburgh, Scotland, UK
| | | | - D Stoyanov
- Centre for Medical Image Computing and the Department of Computer Science, University College London, London, UK
| | - C M Oddo
- The BioRobotics Institute of Scuola Superiore Sant'Anna, Pontedera, Pisa 56025 Italy
| | | | - A Menciassi
- The BioRobotics Institute of Scuola Superiore Sant'Anna, Pontedera, Pisa 56025 Italy
| | - M Morino
- Department of Surgical Disciplines, University of Torino, Torino, Italy
| | - M O Schurr
- Ovesco Endoscopy AG, Tübingen, Germany.,Steinbeis University Berlin, Berlin, Germany
| | - P Dario
- The BioRobotics Institute of Scuola Superiore Sant'Anna, Pontedera, Pisa 56025 Italy
| |
Collapse
|
58
|
Quantitative Contrast-Enhanced Ultrasound Parameters in Crohn Disease: Their Role in Disease Activity Determination With Ultrasound. AJR Am J Roentgenol 2016; 206:64-73. [PMID: 26700336 DOI: 10.2214/ajr.15.14506] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
OBJECTIVE The primary objective of our study was to examine the association between contrast-enhanced ultrasound (CEUS) parameters and established gray-scale ultrasound with color Doppler imaging (CDI) for the determination of disease activity in patients with Crohn disease. Our secondary objective was to develop quantitative time-signal intensity curve thresholds for disease activity. MATERIALS AND METHODS One hundred twenty-seven patients with Crohn disease underwent ultrasound with CDI and CEUS. Reviewers graded wall thickness, inflammatory fat, and mural blood flow as showing remission or inflammation (mild, moderate, or severe). If both gray-scale ultrasound and CDI predicted equal levels of disease activity, the studies were considered concordant. If ultrasound images suggested active disease not supported by CDI findings, the ultrasound results for disease activity were indeterminate. Time-signal intensity curves from CEUS were acquired with calculation of peak enhancement (PE), and AUCs. Interobserver variation and associations between PE and ultrasound parameters were examined. Multiclass ROC analysis was used to develop CEUS thresholds for activity. RESULTS Ninety-six (76%) studies were concordant, 19 of which showed severe disease, and 31 (24%) studies were indeterminate. Kappa analyses revealed good interobserver agreement on grades for CDI (κ = 0.76) and ultrasound (κ = 0.80) assessments. PE values on CEUS and wall thickness showed good association with the Spearman rank correlation coefficient for the entire population (ρ = 0.62, p < 0.01) and for the concordant group (ρ = 0.70, p < 0.01). Multiclass ROC analyses of the concordant group using wall thickness alone as the reference standard showed cutoff points of 18.2 dB for differentiating mild versus moderate activity (sensitivity, 89.0% and specificity, 87.0%) and 23.0 dB for differentiating moderate versus severe (sensitivity, 90% and specificity, 86.8%). Almost identical cutoff points were observed when using ultrasound global assessment as the reference standard: using 18.2 dB to differentiate mild versus moderate activity yielded sensitivity of 89.2% and specificity of 90.9% and using 22.9 dB to differentiate moderate versus severe activity yielded sensitivity of 89.5% and specificity of 83.1%. CONCLUSION Quantitative CEUS parameters integrated into inflammatory assessments with ultrasound reduce indeterminate results and improve disease activity level determinations.
Collapse
|
59
|
Hejazi RA, Bashashati M, Saadi M, Mulla ZD, Sarosiek I, McCallum RW, Zuckerman MJ. Video Capsule Endoscopy: A Tool for the Assessment of Small Bowel Transit Time. Front Med (Lausanne) 2016; 3:6. [PMID: 26904544 PMCID: PMC4748027 DOI: 10.3389/fmed.2016.00006] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2015] [Accepted: 01/25/2016] [Indexed: 12/20/2022] Open
Abstract
Purpose Video capsule endoscopy (VCE) is a procedure that uses a wireless camera to take pictures of the gastrointestinal (GI) tract. A wireless motility capsule (WMC) of a similar size has been developed, which measures pH, pressure, and temperature and can be used to assess regional and total GI transit times. VCE could also potentially be used as a tool for measuring small bowel transit time (SBTT). Methods This study was designed to obtain SBTT from VCE and compare it with historical data generated by WMC. Gastric transit time (GTT) was also measured. Patients were included if the indication for VCE was either iron deficiency anemia (IDA) or overt obscure GI bleed (OOGIB), and they did not have any known motility disorder. Results from VCE were also compared in diabetic vs. non-diabetic patients. Results There were a total of 147 VCE studies performed, including 42 for OOGIB and 105 for IDA. Median GTT and SBTT were 0.3 and 3.6 h, respectively. The overall median GTT and SBTT were 0.3 and 3.6 h, respectively, in the IDA group compared with 0.3 and 3.4 h in the OOGIB group. When compared with WMC, the GTT and SBTT were significantly faster in both groups (GTT: 3.6 h and SBTT: 4.6 h). The median GTT and SBTT were not significantly different in diabetics vs. non-diabetics [GTT: 17.5 vs. 18.0 min (P = 0.86) and SBTT: 3.9 h (237 min) vs. 3.8 h (230 min), respectively (P = 0.90)]. Conclusion SBTT as measured using VCE is not significantly different in OOGIB compared with IDA. Both GTT and SBTT are significantly faster as assessed by VCE, which is initiated in the fasting state, compared with WMC measurement, which is initiated after a standard meal. In summary, VCE could potentially be used for measuring SBTT in the fasting state.
Collapse
Affiliation(s)
- Reza A Hejazi
- Division of Gastroenterology, Department of Medicine, Mayo Clinic , Jacksonville, FL , USA
| | - Mohammad Bashashati
- Division of Gastroenterology, Department of Medicine, Texas Tech University Health Sciences Center , El Paso, TX , USA
| | - Mohammed Saadi
- Division of Gastroenterology, Department of Medicine, Temple University , Philadelphia, PA , USA
| | - Zuber D Mulla
- Department of Obstetrics and Gynecology, Texas Tech University Health Sciences Center, El Paso, TX, USA; Department of Public Health, Texas Tech University Health Sciences Center, Lubbock, TX, USA
| | - Irene Sarosiek
- Division of Gastroenterology, Department of Medicine, Texas Tech University Health Sciences Center , El Paso, TX , USA
| | - Richard W McCallum
- Division of Gastroenterology, Department of Medicine, Texas Tech University Health Sciences Center , El Paso, TX , USA
| | - Marc J Zuckerman
- Division of Gastroenterology, Department of Medicine, Texas Tech University Health Sciences Center , El Paso, TX , USA
| |
Collapse
|
60
|
Kwack WG, Lim YJ. Current Status and Research into Overcoming Limitations of Capsule Endoscopy. Clin Endosc 2016; 49:8-15. [PMID: 26855917 PMCID: PMC4743729 DOI: 10.5946/ce.2016.49.1.8] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/11/2015] [Revised: 09/16/2015] [Accepted: 09/16/2015] [Indexed: 12/13/2022] Open
Abstract
Endoscopic investigation has a critical role in the diagnosis and treatment of gastrointestinal (GI) diseases. Since 2001, capsule endoscopy (CE) has been available for small-bowel exploration and is under continuous development. During the past decade, CE has achieved impressive improvements in areas such as miniaturization, resolution, and battery life. As a result, CE is currently a first-line tool for the investigation of the small bowel in obscure gastrointestinal bleeding and is a useful alternative to wired enteroscopy. Nevertheless, CE still has several limitations, such as incomplete examination and limited diagnostic and therapeutic capabilities. To resolve these problems, many groups have suggested several models (e.g., controlled CO2 insufflation system, magnetic navigation system, mobile robotic platform, tagging and biopsy equipment, and targeted drug-delivery system), which are in development. In the near future, new technological advances will improve the capabilities of CE and broaden its spectrum of applications not only for the small bowel but also for the colon, stomach, and esophagus. The purpose of this review is to introduce the current status of CE and to review the ongoing development of solutions to address its limitations.
Collapse
Affiliation(s)
- Won Gun Kwack
- Department of Internal Medicine, Dongguk University Ilsan Hospital, Dongguk University College of Medicine, Goyang, Korea
| | - Yun Jeong Lim
- Department of Internal Medicine, Dongguk University Ilsan Hospital, Dongguk University College of Medicine, Goyang, Korea
| |
Collapse
|
61
|
Song HJ, Shim KN. Current status and future perspectives of capsule endoscopy. Intest Res 2016; 14:21-9. [PMID: 26884731 PMCID: PMC4754518 DOI: 10.5217/ir.2016.14.1.21] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2015] [Revised: 09/15/2015] [Accepted: 09/17/2015] [Indexed: 02/06/2023] Open
Abstract
Small bowel capsule endoscopy (CE) was first introduced 15 years ago, and a large amount of literature has since been produced, focused on its indication, diagnostic yields, and safety. Guidelines that have made CE the primary diagnostic tool for small bowel disease have been created. Since its initial use in the small bowel, CE has been used for the esophagus, stomach, and colon. The primary indications for small bowel CE are obscure gastrointestinal bleeding, unexplained iron deficiency anemia, suspected Crohn's disease, small bowel tumors, nonsteroidal anti-inflammatory drug enteropathy, portal hypertensive enteropathy, celiac disease, etc. Colon CE provides an alternative to conventional colonoscopy, with possible use in colorectal cancer screening. Guidelines for optimal bowel preparation of CE have been suggested. The main challenges in CE are the development of new devices with the ability to provide therapy, air inflation for better visualization of the small bowel, biopsy sampling systems attached to the capsule, and the possibility of guiding and moving the capsule by an external motion controller. We review the current status and future directions of CE, and address all aspects of clinical practice, including the role of CE and long-term clinical outcomes.
Collapse
Affiliation(s)
- Hyun Joo Song
- Department of Internal Medicine, Jeju National University School of Medicine, Jeju, Korea
| | - Ki-Nam Shim
- Department of Internal Medicine, Ewha Womans University School of Medicine, Seoul, Korea
| |
Collapse
|
62
|
Al-Rawhani MA, Beeley J, Cumming DRS. Wireless fluorescence capsule for endoscopy using single photon-based detection. Sci Rep 2015; 5:18591. [PMID: 26678456 PMCID: PMC4683524 DOI: 10.1038/srep18591] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2015] [Accepted: 11/23/2015] [Indexed: 12/19/2022] Open
Abstract
Fluorescence Imaging (FI) is a powerful technique in biological science and clinical medicine. Current FI devices that are used either for in-vivo or in-vitro studies are expensive, bulky and consume substantial power, confining the technique to laboratories and hospital examination rooms. Here we present a miniaturised wireless fluorescence endoscope capsule with low power consumption that will pave the way for future FI systems and applications. With enhanced sensitivity compared to existing technology we have demonstrated that the capsule can be successfully used to image tissue autofluorescence and targeted fluorescence via fluorophore labelling of tissues. The capsule incorporates a state-of-the-art complementary metal oxide semiconductor single photon avalanche detector imaging array, miniaturised optical isolation, wireless technology and low power design. When in use the capsule consumes only 30.9 mW, and deploys very low-level 468 nm illumination. The device has the potential to replace highly power-hungry intrusive optical fibre based endoscopes and to extend the range of clinical examination below the duodenum. To demonstrate the performance of our capsule, we imaged fluorescence phantoms incorporating principal tissue fluorophores (flavins) and absorbers (haemoglobin). We also demonstrated the utility of marker identification by imaging a 20 μM fluorescein isothiocyanate (FITC) labelling solution on mammalian tissue.
Collapse
Affiliation(s)
| | - James Beeley
- School of Engineering, University of Glasgow, Oakfield Avenue, Glasgow G12 8LT, UK
| | - David R S Cumming
- School of Engineering, University of Glasgow, Oakfield Avenue, Glasgow G12 8LT, UK
| |
Collapse
|
63
|
Koulaouzidis A, Iakovidis DK. Robust capsule endoscopy lesion quantification and localization systems. Comput Biol Med 2015; 65:267-8. [PMID: 25906948 DOI: 10.1016/j.compbiomed.2015.04.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Affiliation(s)
| | - Dimitris K Iakovidis
- Department of Computer Engineering, Technological Educational Institute of Central Greece, Greece
| |
Collapse
|
64
|
Optimizing the interpretation of capsule endoscopic images: shortsighted or taking the long view? Dig Dis Sci 2015; 60:1519-21. [PMID: 25724167 DOI: 10.1007/s10620-015-3601-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/16/2015] [Accepted: 02/18/2015] [Indexed: 12/30/2022]
|