101
|
Dispersive magnetic immunoaffinity extraction. Anatoxin-a determination. J Chromatogr A 2017; 1529:57-62. [DOI: 10.1016/j.chroma.2017.10.076] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2017] [Revised: 10/19/2017] [Accepted: 10/31/2017] [Indexed: 01/01/2023]
|
102
|
Che D, Cheng J, Ji Z, Zhang S, Li G, Sun Z, You J. Recent advances and applications of polydopamine-derived adsorbents for sample pretreatment. Trends Analyt Chem 2017. [DOI: 10.1016/j.trac.2017.08.002] [Citation(s) in RCA: 54] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
|
103
|
Reyes-Garcés N, Gionfriddo E, Gómez-Ríos GA, Alam MN, Boyacı E, Bojko B, Singh V, Grandy J, Pawliszyn J. Advances in Solid Phase Microextraction and Perspective on Future Directions. Anal Chem 2017; 90:302-360. [DOI: 10.1021/acs.analchem.7b04502] [Citation(s) in RCA: 402] [Impact Index Per Article: 57.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
| | | | | | - Md. Nazmul Alam
- Department of Chemistry, University of Waterloo, Ontario, Canada N2L 3G1
| | - Ezel Boyacı
- Department of Chemistry, Middle East Technical University, Ankara 06800, Turkey
| | - Barbara Bojko
- Department of Pharmacodynamics and Molecular Pharmacology, Faculty of Pharmacy, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Toruń, 85-067 Bydgoszcz, Poland
| | - Varoon Singh
- Department of Chemistry, University of Waterloo, Ontario, Canada N2L 3G1
| | - Jonathan Grandy
- Department of Chemistry, University of Waterloo, Ontario, Canada N2L 3G1
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Ontario, Canada N2L 3G1
| |
Collapse
|
104
|
Amiri A, Ghaemi F. Graphene grown on stainless steel mesh as a highly efficient sorbent for sorptive microextraction of polycyclic aromatic hydrocarbons from water samples. Anal Chim Acta 2017; 994:29-37. [DOI: 10.1016/j.aca.2017.08.049] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2017] [Revised: 08/23/2017] [Accepted: 08/26/2017] [Indexed: 12/31/2022]
|
105
|
Böhm L, Düring RA, Bruckert HJ, Schlechtriem C. Can solid-phase microextraction replace solvent extraction for water analysis in fish bioconcentration studies with highly hydrophobic organic chemicals? ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY 2017; 36:2887-2894. [PMID: 28488290 DOI: 10.1002/etc.3854] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/19/2017] [Revised: 05/02/2017] [Accepted: 05/08/2017] [Indexed: 06/07/2023]
Abstract
With the aim to refine water analysis in fish bioconcentration studies, automated solid-phase microextraction (SPME) was used as an alternative approach to conventional solvent extraction (liquid-liquid extraction [LLE]) for the extraction of 3 hydrophobic organic chemicals (HOCs; log KOW 5.5-7.8) from flow-through studies with rainbow trout (Oncorhynchus mykiss). The results showed that total concentrations extracted by SPME combined with internal standards and LLE are equal. The results further verify the possibility of simultaneous extraction of total and freely dissolved HOC concentrations by SPME. Freely dissolved concentrations allow the assessment of sorption and bioavailability of HOCs in bioconcentration studies and their potential impact on resulting bioconcentration factors (BCFs). Reduction in freely dissolved water concentrations can result in an underestimation of BCFs if they are calculated based on total water concentrations. For polychlorinated biphenyl (PCB) 153, a significant increase in BCF value was observed when freely dissolved concentrations were taken into account. However, log BCF values calculated based on freely dissolved concentrations did not correlate linearly with log KOW values above 5 to 6. This pointed to further influences besides a reduction in freely dissolved water concentrations by sorption to organic matter. The results can aid in assessment of the factors that influence bioconcentration systems and also give important information regarding the possible replacement of LLE by SPME for water analysis of highly HOCs in fish bioconcentration studies. Environ Toxicol Chem 2017;36:2887-2894. © 2017 The Authors. Environmental Toxicology and Chemistry Published by Wiley Periodicals, Inc. on behalf of SETAC.
Collapse
Affiliation(s)
- Leonard Böhm
- Institute of Soil Science and Soil Conservation, Research Center for BioSystems, Land Use and Nutrition (iFZ), Justus Liebig University Giessen, Giessen, Germany
| | - Rolf-Alexander Düring
- Institute of Soil Science and Soil Conservation, Research Center for BioSystems, Land Use and Nutrition (iFZ), Justus Liebig University Giessen, Giessen, Germany
| | - Hans-Jörg Bruckert
- Fraunhofer Institute for Molecular Biology and Applied Ecology (IME), Schmallenberg, Germany
| | - Christian Schlechtriem
- Fraunhofer Institute for Molecular Biology and Applied Ecology (IME), Schmallenberg, Germany
| |
Collapse
|
106
|
Kubáň P. Salt Removal from Microliter Sample Volumes by Multiple Phase Microelectromembrane Extractions Across Free Liquid Membranes. Anal Chem 2017; 89:8476-8483. [DOI: 10.1021/acs.analchem.7b02017] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Affiliation(s)
- Pavel Kubáň
- Institute of Analytical Chemistry of the Czech Academy of Sciences, v. v. i., Veveří 97, CZ-60200 Brno, Czech Republic
| |
Collapse
|
107
|
Pang L, Yang P, Pang R, Lu X, Xiao J, Li S, Zhang H, Zhao J. Ionogel-Based Ionic Liquid Coating for Solid-Phase Microextraction of Organophosphorus Pesticides from Wine and Juice Samples. FOOD ANAL METHOD 2017. [DOI: 10.1007/s12161-017-0997-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
108
|
Almeida MIGS, Cattrall RW, Kolev SD. Polymer inclusion membranes (PIMs) in chemical analysis - A review. Anal Chim Acta 2017; 987:1-14. [PMID: 28916032 DOI: 10.1016/j.aca.2017.07.032] [Citation(s) in RCA: 99] [Impact Index Per Article: 14.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2017] [Revised: 07/09/2017] [Accepted: 07/12/2017] [Indexed: 11/27/2022]
Abstract
This review highlights the increasing interest in polymer inclusion membranes (PIMs) in analytical chemistry as they are adapted to new and novel applications. PIMs are polymer-based liquid membranes and were first introduced 50 years ago as the sensing membranes in ion-selective electrodes and optodes. More recently however, PIMs have been used for other applications in analytical chemistry such as for sample separation, sample pre-concentration, electro-driven extraction, and passive sampling, and have also been incorporated into on-line and automated analysis systems. The present review provides a general overview of the analytical chemistry applications of PIMs reported in the literature to date and illustrates their versatility for solving challenging chemical analysis problems.
Collapse
Affiliation(s)
- M Inês G S Almeida
- School of Chemistry, The University of Melbourne, Victoria 3010, Australia
| | - Robert W Cattrall
- School of Chemistry, The University of Melbourne, Victoria 3010, Australia
| | - Spas D Kolev
- School of Chemistry, The University of Melbourne, Victoria 3010, Australia.
| |
Collapse
|
109
|
In situ hydrothermal growth of a zirconium-based porphyrinic metal-organic framework on stainless steel fibers for solid-phase microextraction of nitrated polycyclic aromatic hydrocarbons. Mikrochim Acta 2017. [DOI: 10.1007/s00604-017-2403-0] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
110
|
Heidari N, Ghiasvand A, Abdolhosseini S. Amino-silica/graphene oxide nanocomposite coated cotton as an efficient sorbent for needle trap device. Anal Chim Acta 2017; 975:11-19. [DOI: 10.1016/j.aca.2017.04.031] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2017] [Revised: 04/10/2017] [Accepted: 04/20/2017] [Indexed: 10/19/2022]
|
111
|
Piri-Moghadam H, Alam MN, Pawliszyn J. Review of geometries and coating materials in solid phase microextraction: Opportunities, limitations, and future perspectives. Anal Chim Acta 2017; 984:42-65. [PMID: 28843569 DOI: 10.1016/j.aca.2017.05.035] [Citation(s) in RCA: 208] [Impact Index Per Article: 29.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2017] [Revised: 05/23/2017] [Accepted: 05/25/2017] [Indexed: 12/18/2022]
Abstract
The development of new support and geometries of solid phase microextraction (SPME), including metal fiber assemblies, coated-tip, and thin film microextraction (TFME) (i.e. self-supported, fabric and blade supported), as well as their effects on diffusion and extraction rate of analytes were discussed in the current review. Application of main techniques widely used for preparation of a variety of coating materials of SPME, including sol-gel technique, electrochemical and electrospinning methods as well as the available commercial coatings, were presented. Advantages and limitations of each technique from several aspects, such as range of application, biocompatibility, availability in different geometrical configurations, method of preparation, incorporation of various materials to tune the coating properties, and thermal and physical stability, were also investigated. Future perspectives of each technique to improve the efficiency and stability of the coatings were also summarized. Some interesting materials including ionic liquids (ILs), metal organic frameworks (MOFs) and particle loaded coatings were briefly presented.
Collapse
Affiliation(s)
- Hamed Piri-Moghadam
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| | - Md Nazmul Alam
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada.
| |
Collapse
|
112
|
Metal-organic aerogel as a coating for solid-phase microextraction. Anal Chim Acta 2017; 973:51-58. [DOI: 10.1016/j.aca.2017.04.029] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2017] [Revised: 04/12/2017] [Accepted: 04/20/2017] [Indexed: 12/13/2022]
|
113
|
Sample treatment procedures for environmental sensing and biosensing. Curr Opin Biotechnol 2017; 45:170-174. [DOI: 10.1016/j.copbio.2017.02.017] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2017] [Revised: 02/24/2017] [Accepted: 02/28/2017] [Indexed: 01/15/2023]
|
114
|
Inter-laboratory validation of a thin film microextraction technique for determination of pesticides in surface water samples. Anal Chim Acta 2017; 964:74-84. [DOI: 10.1016/j.aca.2017.02.014] [Citation(s) in RCA: 45] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2016] [Revised: 01/30/2017] [Accepted: 02/01/2017] [Indexed: 12/22/2022]
|
115
|
Silica- and germania-based dual-ligand sol-gel organic-inorganic hybrid sorbents combining superhydrophobicity and π-π interaction. The role of inorganic substrate in sol-gel capillary microextraction. Anal Chim Acta 2017; 964:96-111. [DOI: 10.1016/j.aca.2017.02.031] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2016] [Revised: 02/22/2017] [Accepted: 02/27/2017] [Indexed: 11/22/2022]
|
116
|
Determination of short chain chlorinated paraffins in water by stir bar sorptive extraction–thermal desorption–gas chromatography–triple quadrupole tandem mass spectrometry. J Chromatogr A 2017; 1494:77-80. [DOI: 10.1016/j.chroma.2017.03.012] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2017] [Revised: 03/06/2017] [Accepted: 03/07/2017] [Indexed: 11/17/2022]
|
117
|
Seebunrueng K, Dejchaiwatana C, Santaladchaiyakit Y, Srijaranai S. Development of supramolecular solvent based microextraction prior to high performance liquid chromatography for simultaneous determination of phenols in environmental water. RSC Adv 2017. [DOI: 10.1039/c7ra07780g] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
Abstract
SUPRAS based microextraction for phenols.
Collapse
Affiliation(s)
- Ketsarin Seebunrueng
- Materials Chemistry Research Center
- Department of Chemistry and Center of Excellence for Innovation in Chemistry
- Faculty of Science
- Khon Kaen University
- Khon Kaen 40002
| | - Chaiyawat Dejchaiwatana
- Materials Chemistry Research Center
- Department of Chemistry and Center of Excellence for Innovation in Chemistry
- Faculty of Science
- Khon Kaen University
- Khon Kaen 40002
| | - Yanawath Santaladchaiyakit
- Department of Chemistry
- Faculty of Engineering
- Rajamangala University of Technology Isan
- Khon Kaen 40000
- Thailand
| | - Supalax Srijaranai
- Materials Chemistry Research Center
- Department of Chemistry and Center of Excellence for Innovation in Chemistry
- Faculty of Science
- Khon Kaen University
- Khon Kaen 40002
| |
Collapse
|
118
|
Wohde M, Bartz JO, Böhm L, Hartwig C, Keil BM, Martin K, Düring RA. Automated thin-film microextraction coupled to a flow-through cell: somewhere in between passive and active sampling. Anal Bioanal Chem 2016; 409:1975-1984. [PMID: 28012111 DOI: 10.1007/s00216-016-0145-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2016] [Revised: 12/01/2016] [Accepted: 12/12/2016] [Indexed: 10/20/2022]
Abstract
A prototype for the automated thin-film microextraction of pharmaceuticals from aqueous solutions has been developed and is presented here for the first time. With a software-controlled setup, extraction methods for ivermectin and iohexol have been developed. The widely used antiparasitic agent ivermectin is non-polar and has a high tendency to sorb to surfaces. In contrast to this, the nonionic but polar iodinated X-ray contrast agent iohexol is freely water soluble. With these two substances, a wide range of polarity is covered. Sorption kinetics and thermodynamics of ivermectin and iohexol were studied. With the presented passive sampling approach, it was possible to extract up to 96.2% ivermectin with a C18-phase within 1 h and up to 74.6% of iohexol with a PS-DVB phase within 36 h out of water. Using abamectin as internal standard, it was possible to quantitatively follow dissipation of ivermectin in a simulated surface water experiment. Predominantly, the newly developed prototype can be used for automated and time-resolved extraction of xenobiotics from waterbodies under field conditions, for the extraction of substances under laboratory conditions as an alternative to the elaborate solid-phase extraction, and for the automated control of chemical reaction kinetics.
Collapse
Affiliation(s)
- Manuel Wohde
- Institute of Soil Science and Soil Conservation, Justus Liebig University Giessen, IFZ, Heinrich-Buff-Ring 26-32, 35392, Giessen, Germany.
| | - Jens-Ole Bartz
- Department of Applied Microbiology, Justus Liebig University Giessen, Heinrich-Buff-Ring 26-32, 35392, Giessen, Germany
| | - Leonard Böhm
- Institute of Soil Science and Soil Conservation, Justus Liebig University Giessen, IFZ, Heinrich-Buff-Ring 26-32, 35392, Giessen, Germany
| | - Christoph Hartwig
- Institute of Soil Science and Soil Conservation, Justus Liebig University Giessen, IFZ, Heinrich-Buff-Ring 26-32, 35392, Giessen, Germany
| | - Benjamin Martin Keil
- Institute of Soil Science and Soil Conservation, Justus Liebig University Giessen, IFZ, Heinrich-Buff-Ring 26-32, 35392, Giessen, Germany
| | - Katharina Martin
- Institute of Soil Science and Soil Conservation, Justus Liebig University Giessen, IFZ, Heinrich-Buff-Ring 26-32, 35392, Giessen, Germany
| | - Rolf-Alexander Düring
- Institute of Soil Science and Soil Conservation, Justus Liebig University Giessen, IFZ, Heinrich-Buff-Ring 26-32, 35392, Giessen, Germany
| |
Collapse
|
119
|
Piri-Moghadam H, Lendor S, Pawliszyn J. Development of a Biocompatible In-Tube Solid-Phase Microextraction Device: A Sensitive Approach for Direct Analysis of Single Drops of Complex Matrixes. Anal Chem 2016; 88:12188-12195. [PMID: 28193058 DOI: 10.1021/acs.analchem.6b03160] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Affiliation(s)
- Hamed Piri-Moghadam
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L
3G1, Canada
| | - Sofia Lendor
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L
3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L
3G1, Canada
| |
Collapse
|
120
|
Fiscal-Ladino JA, Obando-Ceballos M, Rosero-Moreano M, Montaño DF, Cardona W, Giraldo LF, Richter P. Ionic liquids intercalated in montmorillonite as the sorptive phase for the extraction of low-polarity organic compounds from water by rotating-disk sorptive extraction. Anal Chim Acta 2016; 953:23-31. [PMID: 28010739 DOI: 10.1016/j.aca.2016.11.067] [Citation(s) in RCA: 43] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2016] [Revised: 10/26/2016] [Accepted: 11/24/2016] [Indexed: 01/09/2023]
Abstract
Montmorillonite (MMT) clays were modified by the intercalation into their galleries of ionic liquids (IL) based on imidazolium quaternary ammonium salts. This new eco-materials exhibited good features for use as a sorptive phase in the extraction of low-polarity analytes from aqueous samples. Spectroscopic analyses of the modified clays were conducted and revealed an increase in the basal spacing and a shifting of the reflection plane towards lower values as a consequence of the effective intercalation of organic cations into the MMT structure. The novel sorbent developed herein was assayed as the sorptive phase in rotating-disk sorptive extraction (RDSE), using polychlorinated biphenyls (PCBs), representative of low-polarity pollutants, as model analytes. The final determination was made by gas chromatography with electron capture detection. Among the synthetized sorptive phases, the selected system for analytical purposes consisted of MMT modified with the 1-hexadecyl-3-methylimidazolium bromide (HDMIM-Br) IL. Satisfactory analytical features were achieved using a sample volume of 5 mL: the relative recoveries from a wastewater sample were higher than 80%, the detection limits were between 3 ng L-1 and 43 ng L-1, the precision (within-run precision) expressed as the relative standard deviation ranged from 2% to 24%, and the enrichment factors ranged between 18 and 28. Using RDSE, the extraction efficiency achieved for the selected MMT-HDMIM-Br phase was compared with other commercial solid phases/supports, such as polypropylene, polypropylene with 1-octanol (as a supported liquid membrane), octadecyl (C18) and octyl (C8), and showed the highest response for all the studied analytes. Under the optimized extraction conditions, this new device was applied in the analysis of the influent of a wastewater treatment plant in Santiago (Chile), demonstrating its applicability through the good recoveries and precision achieved with real samples.
Collapse
Affiliation(s)
- Jhon A Fiscal-Ladino
- Grupo de Investigación en Cromatografía y Técnicas Afines GICTA, Departamento de Química, Facultad de Ciencias Exactas y Naturales, Universidad de Caldas, Calle 65 No. 26-10, Manizales, Colombia
| | - Mónica Obando-Ceballos
- Grupo de Investigación en Cromatografía y Técnicas Afines GICTA, Departamento de Química, Facultad de Ciencias Exactas y Naturales, Universidad de Caldas, Calle 65 No. 26-10, Manizales, Colombia
| | - Milton Rosero-Moreano
- Grupo de Investigación en Cromatografía y Técnicas Afines GICTA, Departamento de Química, Facultad de Ciencias Exactas y Naturales, Universidad de Caldas, Calle 65 No. 26-10, Manizales, Colombia
| | - Diego F Montaño
- Química de Plantas Colombianas, Instituto de Química, Escuela de Ciencias Exactas y Naturales, Universidad de Antioquia, Calle 70 No. 52-21, A.A, 1226, Medellín, Colombia
| | - Wilson Cardona
- Química de Plantas Colombianas, Instituto de Química, Escuela de Ciencias Exactas y Naturales, Universidad de Antioquia, Calle 70 No. 52-21, A.A, 1226, Medellín, Colombia
| | - Luis F Giraldo
- Química de Plantas Colombianas, Instituto de Química, Escuela de Ciencias Exactas y Naturales, Universidad de Antioquia, Calle 70 No. 52-21, A.A, 1226, Medellín, Colombia
| | - Pablo Richter
- Departamento de Química Inorgánica y Analítica, Facultad de Ciencias Químicas y Farmacéuticas, Universidad de Chile, Casilla 233, Santiago, Chile.
| |
Collapse
|