101
|
Adi H, Larson I, Chiou H, Young P, Traini D, Stewart P. Agglomerate Strength and Dispersion of Salmeterol Xinafoate from Powder Mixtures for Inhalation. Pharm Res 2006; 23:2556-65. [PMID: 16972185 DOI: 10.1007/s11095-006-9082-6] [Citation(s) in RCA: 69] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2006] [Accepted: 06/05/2006] [Indexed: 11/29/2022]
Abstract
PURPOSE The study investigated the role of agglomeration and the effect of fine lactose size on the dispersion of salmeterol xinafoate (SX) from SX-lactose mixtures for inhalation. METHODS Particle size distributions were characterised by Malvern Mastersizer S, Aerosizer and Spraytec, and imaging conducted by scanning electron microscopy (SEM). Inter-particulate adhesion was quantified by atomic force microscopy. Deposition of SX was measured using a twin stage impinger. SX was analysed using validated high-performance liquid chromatography method (r(2)=1.0, CV=0.4-1.0%). RESULTS Addition of fine lactose with a volume median diameter (VMD) of 7.9 microm to a SX-lactose carrier and carrier-free mixture resulted in significantly better dispersion (16.8% for 20% added fine lactose) than fractions with VMD of 3.0, 17.7 and 33.3 microm (less than 9.1% for 20% fine lactose). Using the carrier-free mixtures, particle sizing of the aerosol cloud using the Spraytec, coupled with the application of the Aerosizer using differing dispersion energies and SEMs of the samples, indicated that an open packed, agglomerate structure improved SX dispersion. The highest extent of SX dispersion occurred when SX and fine lactose were detached from the surface, usually in the form of loose agglomerates. CONCLUSIONS The outcomes of this research demonstrated how agglomerate structure influenced dispersion and the key role of fine lactose particle size in SX dispersion from mixtures for inhalation.
Collapse
Affiliation(s)
- Handoko Adi
- Department of Pharmaceutics, Victorian College of Pharmacy, Monash University, 381 Royal Parade, Parkville, Victoria 3052, Australia
| | | | | | | | | | | |
Collapse
|
102
|
Giry K, Péan JM, Giraud L, Marsas S, Rolland H, Wüthrich P. Drug/lactose co-micronization by jet milling to improve aerosolization properties of a powder for inhalation. Int J Pharm 2006; 321:162-6. [PMID: 16797150 DOI: 10.1016/j.ijpharm.2006.05.009] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2005] [Revised: 04/07/2006] [Accepted: 05/05/2006] [Indexed: 11/25/2022]
Abstract
The aim of this work was to formulate a powder for inhalation with fusafungine, a drug substance initially highly cohesive. The classical approach based on micronization by jet milling to prepare respirable drug particles and then blending with a carrier was first applied. A fractional factorial experimental design was implemented to screen six formulation parameters. The effect of drug/lactose co-micronization on aerosolization was then evaluated. In vitro deposition studies were performed with the twin stage glass impinger and the inhaler Spinhaler. Micronization did not induce DSC-detectable amorphization and gave a highly cohesive, poor flowable powder with a theoretical aerodynamic diameter of 5 microm. The powder was then blended with coarse lactose and optionally fine lactose. Unfortunately, the respirable fraction could not be optimized and remained below 10%. On the other hand, a co-micronized powder drug/fine lactose 50:50 gave a respirable fraction of 16%. Following blending with a carrier, the respirable fraction and the emitted dose fraction reached 23% and 69%, respectively. The use of a fine lactose grade for co-micronization was essential. In conclusion, this study demonstrated that co-micronization with a fine lactose is an efficient and simple strategy to formulate a powder for inhalation with enhanced aerosolization properties, especially for highly cohesive drug substance.
Collapse
Affiliation(s)
- K Giry
- Technologie Servier, 25/27 Rue Eugène Vignat, 45000 Orléans, France
| | | | | | | | | | | |
Collapse
|
103
|
Chan HK. Dry powder aerosol drug delivery—Opportunities for colloid and surface scientists. Colloids Surf A Physicochem Eng Asp 2006. [DOI: 10.1016/j.colsurfa.2005.10.091] [Citation(s) in RCA: 76] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
104
|
Young PM, Tobyn MJ, Price R, Buttrum M, Dey F. The use of colloid probe microscopy to predict aerosolization performance in dry powder inhalers: AFM and in vitro correlation. J Pharm Sci 2006; 95:1800-9. [PMID: 16795018 DOI: 10.1002/jps.20660] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The atomic force microscope (AFM) colloid probe technique was utilized to measure cohesion forces (separation energy) between three drug systems as a function of relative humidity (RH). The subsequent data was correlated with in vitro aerosolization data collected over the same RH range. Three drug-only systems were chosen for study; salbutamol sulphate (SS), triamcinolone acetonide (TAA), and di-sodium cromoglycate (DSCG). Analysis of the AFM and in vitro data suggested good correlations, with the separation energy being related inversely to the aerosolization performance (measured as fine particle fraction, FPF(LD)). In addition, the relationship between, cohesion, RH, and aerosolization performance was drug specific. For example, an increase in RH between 15% and 75% resulted in increased cohesion and decreased FPF(LD) for SS and DSCG. In comparison, for TAA, a decrease in cohesion and increased FPF(LD) was observed when RH was increased (15-75%). Linear regression analysis comparing AFM with in vitro data indicated R(2) values > 0.80, for all data sets, suggesting the AFM could be used to indicate in vitro aerosolization performance.
Collapse
Affiliation(s)
- Paul M Young
- Pharmaceutical Technology Research Group, Department of Pharmacy, University of Bath, UK
| | | | | | | | | |
Collapse
|
105
|
Jones MD, Price R. The Influence of Fine Excipient Particles on the Performance of Carrier-Based Dry Powder Inhalation Formulations. Pharm Res 2006; 23:1665-74. [PMID: 16845584 DOI: 10.1007/s11095-006-9012-7] [Citation(s) in RCA: 144] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2006] [Accepted: 03/17/2006] [Indexed: 10/24/2022]
Abstract
The inclusion of a small amount of fine particle excipient in a carrier-based dry powder inhalation system is a well researched technique to improve formulation performance and is employed in the pharmaceutical industry. The removal of intrinsic fines from a lactose carrier has been found to decrease formulation performance, whereas adding fines of many different materials into formulations increased performance. Changing the particle size of these fines, the amount added and the technique by which they were prepared also affected formulation behaviour. Despite this body of research, there is disagreement as to the mechanism by which fines improved formulation performance, with two main hypotheses presented in the literature. The first hypothesis suggested that fines prevent the drug from adhering to the strongest binding sites on the carrier, whilst the second proposed that fine particles of drug and excipient form mixed agglomerates that are more easily dispersed and deaggregated during aerosolisation. The evidence in support of each hypothesis is limited and it is clear that future research should aim to produce stronger mechanistic evidence. The investigation of interparticulate interactions using techniques such as atomic force microscopy and inverse gas chromatography may prove useful in achieving this aim.
Collapse
Affiliation(s)
- Matthew D Jones
- Pharmaceutical Surface Science Research Group, Department of Pharmacy and Pharmacology, University of Bath, Bath, BA2 7AY, UK
| | | |
Collapse
|
106
|
Hooton JC, Jones MD, Price R. Predicting the behavior of novel sugar carriers for dry powder inhaler formulations via the use of a cohesive–adhesive force balance approach. J Pharm Sci 2006; 95:1288-97. [PMID: 16637052 DOI: 10.1002/jps.20618] [Citation(s) in RCA: 62] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The aim of this work was to utilize the recently developed cohesive-adhesive balance (CAB) technique for analyzing quantitative AFM measurements to compare the relative forces of interaction of micronized salbutamol sulfate particles and a selection of specifically grown sugar substrates (beta cyclodextrin, lactose, raffinose, trehalose and xylitol). The interfacial behavior was subsequently related to the in-vitro delivery performance of these sugars as carrier particles in dry powder inhalation (DPI) formulations. The CAB analysis indicated that the rank order of adhesion between salbutamol sulfate and the sugars was beta cyclodextrin < lactose < trehalose < raffinose < xylitol. The beta cyclodextrin was the only substrate with which salbutamol sulfate demonstrated a greater cohesive behavior. All other sugars exhibited an adhesive dominance. In-vitro deposition performance of the salbutamol sulfate based carrier DPI formulations showed that the rank order of the fine particle fraction (FPF) was beta cyclodextrin > lactose > raffinose > trehalose > xylitol. A linear correlation (R(2) = 0.9572) was observed between the FPF and cohesive-adhesive ratios of the AFM force measurements. The observed link between CAB analysis of the interactive forces and in-vitro performance of carrier based formulations suggested a fundamental understanding of the relative balance of the various forces of interaction within a dry powder formulation may provide a critical insight into the behavior of these formulations.
Collapse
Affiliation(s)
- Jennifer C Hooton
- Pharmaceutical Surface Science Research Group, Department of Pharmacy and Pharmacology, University of Bath, Bath, BA2 7AY, United Kingdom
| | | | | |
Collapse
|
107
|
Abstract
Development of dry powder aerosol delivery system involves powder production, formulation, dispersion, delivery, and deposition of the powder aerosol in the airways. Insufficiency of conventional powder production by crystallization and milling has led to development of alternative techniques. Over the last decade, performance of powder formulations has been improved significantly through the use of engineered drug particles and excipient systems which are (i) of low aerodynamic diameters (being porous or of low particle density), and/or (ii) less cohesive and adhesive (via corrugated surfaces, low bulk density, reduced surface energy and particle interaction, hydrophobic additives, and fine carrier particles). Early insights into particle forces and surface energy that help explain the improvement have been provided by analytical techniques such as the atomic force microscopy (AFM) and inverse gas chromatography (IGC). Relative humidity is critical to the performance of dry powder inhaler (DPI) products via capillary force and electrostatic interaction. Electrostatic charge of different particle size fractions of an aerosol can now be measured using a modified electrical low-pressure impactor (ELPI). Compared with powders, much less work has been done on the inhaler devices at the fundamental level. Most recently, computational fluid dynamics has been applied to understand how the inhaler design (such as mouthpiece, grid structure, air inlet) affects powder dispersion. The USP throat is known to under-represent the oropharyngeal deposition of DPI aerosols. Studies using magnetic resonance imaging (MRI) model casts have been undertaken to explain the inter- and intra- subject variation in oropharyngeal deposition. Most of the lung deposition studies performed on commercial products did not allow a thorough understanding of the determinants affecting in vivo lung deposition. A more systematic approach would be necessary to build a useful database on the dependence of lung deposition on the breathing parameters, inhaler design, and powder formulation properties.
Collapse
Affiliation(s)
- Hak-Kim Chan
- Faculty of Pharmacy, University of Sydney, Sydney, NSW, Australia.
| |
Collapse
|
108
|
de Boer AH, Hagedoorn P, Gjaltema D, Goede J, Frijlink HW. Air classifier technology (ACT) in dry powder inhalation. Int J Pharm 2006; 310:81-9. [PMID: 16442246 DOI: 10.1016/j.ijpharm.2005.11.029] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2004] [Revised: 11/02/2005] [Accepted: 11/07/2005] [Indexed: 11/27/2022]
Abstract
In this study, the in vitro fine particle deposition from a multi dose dry powder inhaler (Novolizer) with air classifier technology has been investigated. It is shown that different target values for the fine particle fraction (fpf<5 microm) of the same drug can be achieved in a well-controlled way. This is particularly relevant to the application of generic formulations in the inhaler. The well-controlled and predictable fpf is achieved through dispersion of different types of formulations in exactly the same classifier concept. On the other hand, it is shown that air classifier-based inhalers are less sensitive to the carrier surface and bulk properties than competitive inhalers like the Diskus. For 10 randomly selected lactose carriers for inhalation from four different suppliers, the budesonide fpf (at 4 kPa) from the Novolizer varied between 30 and 46% (of the measured dose; R.S.D.=14.2%), whereas the extremes in fpf from the Diskus dpi were 7 and 44% (R.S.D.=56.2%) for the same formulations. The fpf from a classifier-based inhaler appears to be less dependent of the amount of lactose (carrier) fines (<15 microm) in the mixture too. Classifier-based inhalers perform best with coarse carriers that have relatively wide size distributions (e.g. 50-350 microm) and surface discontinuities inside which drug particles can find shelter from press-on forces during mixing. Coarse carrier fractions have good flow properties, which increases the dose measuring accuracy and reproducibility. The fpf from the Novolizer increases with increasing pressure drop across the device. On theoretical grounds, it can be argued that this yields a more reproducible therapy, because it compensates for a shift in deposition to larger airways when the flow rate is increased. Support for this reasoning based on lung deposition modelling studies has been found in a scintigraphic study with the Novolizer. Finally, it is shown that this inhaler produces a finer aerosol than competitor devices, within the fpf<5 microm, subfractions of particles (e.g. <1, 1-2, 2-3, 3-4 and 4-5 microm) are higher.
Collapse
Affiliation(s)
- A H de Boer
- Department of Pharmaceutical Technology and Biopharmacy, University of Groningen, A. Deusinglaan 1, 9713 AV Groningen, The Netherlands.
| | | | | | | | | |
Collapse
|
109
|
Beilmann B, Langguth P, Häusler H, Grass P. High-performance liquid chromatography of lactose with evaporative light scattering detection, applied to determine fine particle dose of carrier in dry powder inhalation products. J Chromatogr A 2006; 1107:204-7. [PMID: 16442117 DOI: 10.1016/j.chroma.2005.12.083] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2005] [Revised: 12/09/2005] [Accepted: 12/20/2005] [Indexed: 11/16/2022]
Abstract
A method for quantification of the fine particle dose of lactose is described, using a hydrophilic interaction chromatography (HILIC) method and evaporative light scattering detection. The HILIC method used an aminopropyl column and a mobile phase consisting of acetonitril/water (80/20, v/v) for isocratic elution. Sensitive chromatography was obtained using a low concentration of water in the extraction solvent. The detection limit (RSD<10%) at an injection volume of 10 microL is 10 microg/mL. Linearity was obtained in the range of 10-80 microg/mL (R(2)>0.99). A relative standard deviation (RSD) of 0.5% (N=6) demonstrated good precision of the optimized method.
Collapse
Affiliation(s)
- Bianca Beilmann
- Institute of Pharmacy, Johannes Gutenberg University, 55099 Mainz, Germany
| | | | | | | |
Collapse
|
110
|
Kumon M, Suzuki M, Kusai A, Yonemochi E, Terada K. Novel Approach to DPI Carrier Lactose with Mechanofusion Process with Additives and Evaluation by IGC. Chem Pharm Bull (Tokyo) 2006; 54:1508-14. [PMID: 17077547 DOI: 10.1248/cpb.54.1508] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The effect of lactose carrier surface property on the inhalation profile of dry powder inhaler (DPI) was evaluated using a micronized drug (Compound A) by inverse gas chromatography (IGC). Mechanofusion with magnesium stearate (Mg-St) or sucrose stearate increased the fine particle fraction (FPF), considered to be due to decrease in the interaction between Compound A and the lactose carrier. The effect of Compound A concentration on FPF was smaller in mechanofusion-processed lactose compared to intact lactose, especially when processed with Mg-St. The relationship between the IGC parameters of the lactose and FPF was also investigated. FPF increased as both the dispersive component of the surface energy and acidity similarity between the lactose carriers and Compound A increased. Although further investigation is necessary, it could be suggested that acidity similarity decreases the interaction between Compound A and lactose, thus contributing to the increase in the FPF. In conclusion, (1) mechanofusion with Mg-St or sucrose stearate could be an effective method to improve FPF of a DPI drug formulation; (2) IGC would be a valuable method to investigate the interaction between a drug and the DPI carrier; and (3) a relationship between surface acidity and inhalation profile was suggested.
Collapse
Affiliation(s)
- Michiko Kumon
- Pharmaceutical Development Laboratories, Sankyo Co., Ltd., Hiratsuka, Kanagawa, Japan.
| | | | | | | | | |
Collapse
|
111
|
Coates MS, Chan HK, Fletcher DF, Raper JA. Influence of air flow on the performance of a dry powder inhaler using computational and experimental analyses. Pharm Res 2005; 22:1445-53. [PMID: 16132356 DOI: 10.1007/s11095-005-6155-x] [Citation(s) in RCA: 132] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2005] [Accepted: 05/26/2005] [Indexed: 11/28/2022]
Abstract
PURPOSE The aims of the study are to analyze the influence of air flow on the overall performance of a dry powder inhaler (Aerolizer and to provide an initial quantification of the flow turbulence levels and particle impaction velocities that maximized the inhaler dispersion performance. METHODS Computational fluid dynamics (CFD) analysis of the flow field in the Aerolizer, in conjunction with experimental dispersions of mannitol powder using a multistage liquid impinger, was used to determine how the inhaler dispersion performance varied as the device flow rate was increased. RESULTS Both the powder dispersion and throat deposition were increased with air flow. The capsule retention was decreased with flow, whereas the device retention first increased then decreased with flow. The optimal inhaler performance was found at 65 l min(-1) showing a high fine particle fraction (FPF) of 63 wt.% with low throat deposition (9.0 wt.%) and capsule retention (4.3 wt.%). Computational fluid dynamics analysis showed that at the critical flow rate of 65 l min(-1), the volume-averaged integral scale strain rate (ISSR) was 5,400 s(-1), and the average particle impaction velocities were 12.7 and 19.0 m s(-1) at the inhaler base and grid, respectively. Correlations between the device flow rate and (a) the amount of throat deposition and (b) the capsule emptying times were also developed. CONCLUSIONS The use of CFD has provided further insight into the effect of air flow on the performance of the Aerolizer. The approach of using CFD coupled with powder dispersion is readily applicable to other dry powder inhalers (DPIs) to help better understand their performance optimization.
Collapse
Affiliation(s)
- Matthew S Coates
- Department of Chemical Engineering, University of Sydney, Sydney, NSW, 2006, Australia
| | | | | | | |
Collapse
|
112
|
de Boer AH, Dickhoff BHJ, Hagedoorn P, Gjaltema D, Goede J, Lambregts D, Frijlink HW. A critical evaluation of the relevant parameters for drug redispersion from adhesive mixtures during inhalation. Int J Pharm 2005; 294:173-84. [PMID: 15814242 DOI: 10.1016/j.ijpharm.2005.01.035] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2004] [Revised: 01/18/2005] [Accepted: 01/24/2005] [Indexed: 10/25/2022]
Abstract
In this paper, the parameters that are relevant to the drug redispersion from adhesive mixtures during inhalation are discussed and evaluated. The results obtained with air classifier technology give strong evidence for a dominating influence of carrier surface properties on the fraction of drug detached during inhalation at a low carrier payload (< or =1%, w/w), versus a dominating effect of carrier bulk properties at higher payloads. Furthermore, the results indicate that there is a fundamental difference between so-called active carrier sites and large surface discontinuities. The difference refers to the saturation concentrations, the rates of saturation and their effects on drug detachment during inhalation. The degree of saturation of the active sites appears to be proportional with the square root of the carrier surface payload (after 10 min mixing time in a Turbula mixer at 90 rpm). The storage volume of the discontinuities seems largely independent of the carrier diameter for particles derived from the same batch of crystalline lactose. Saturation of these discontinuities is completed at a much lower carrier surface payload than saturation of the active sites. Relatively large discontinuities are beneficial to de-agglomeration principles that make use of inertial separation forces during inhalation, as they provide shelter from inertial and frictional press-on forces during mixing which increase the strength of the interparticulate bonds in the powder mixture. For de-agglomeration principles generating frictional, drag or lift forces, carrier surface depressions and projections are disadvantageous however, as they also provide shelter from these removal forces.
Collapse
Affiliation(s)
- A H de Boer
- Department of Pharmaceutical Technology and Biopharmacy, Groningen University Institute for Drug Exploration (GUIDE), Ant. Deusinglaan 1, 9713 AV Groningen, The Netherlands.
| | | | | | | | | | | | | |
Collapse
|
113
|
de Boer AH, Hagedoorn P, Gjaltema D, Lambregts D, Irngartinger M, Frijlink HW. The Mode of Drug Particle Detachment from Carrier Crystals in an Air Classifier-Based Inhaler. Pharm Res 2004; 21:2167-74. [PMID: 15648247 DOI: 10.1007/s11095-004-5171-6] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
PURPOSE To investigate the mode of drug particle detachment from carrier crystals in an air classifier as a function of the carrier size fraction, payload, and the circulation time in the classifier. METHODS Laser diffraction analysis of the aerosol cloud from the classifier has been performed at 10, 20, 30, and 60 l/min, using a special adapter, for different adhesive mixture compositions. RESULTS A significant part of the drug particles is detached from carrier crystals during inhalation as small agglomerates. Such agglomerates originate from the starting material or are newly formed on the carrier surface during mixing. The degree of agglomeration during mixing depends on the carrier size, payload, and surface rugosity. The size of the agglomerates that are formed during mixing, increases with the size of the carrier particles. Predominantly the largest drug particles and agglomerates are detached within the first 0.5 s of inhalation. After 0.5 s, smaller primary particles are dislodged. CONCLUSIONS A high ratio of removal forces to adhesive forces causes a high drug detachment rate from carrier crystals in a classifier within the first 0.5 s of inhalation. The high ratio can be explained by dislodgment of agglomerates and the largest primary particles in the early phases of inhalation. At higher flow rates, detached agglomerates may be further disintegrated into primary particles before they are discharged from the classifier. Agglomeration of drug particles on the carrier surface is the result of the same forces that are responsible for pressing these particles firmly to the carrier crystals during mixing.
Collapse
Affiliation(s)
- Anne H de Boer
- Department of Pharmaceutical Technology and Biopharmacy, Groningen University Institute for Drug Exploration, 9713 AV Groningen, The Netherlands.
| | | | | | | | | | | |
Collapse
|
114
|
Thalberg K, Lindholm D, Axelsson A. Comparison of different flowability tests for powders for inhalation. POWDER TECHNOL 2004. [DOI: 10.1016/j.powtec.2004.08.003] [Citation(s) in RCA: 93] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
115
|
Islam N, Stewart P, Larson I, Hartley P. Effect of carrier size on the dispersion of salmeterol xinafoate from interactive mixtures. J Pharm Sci 2004; 93:1030-8. [PMID: 14999738 DOI: 10.1002/jps.10583] [Citation(s) in RCA: 59] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The objective of this study was to determine the influence of lactose carrier size on drug dispersion of salmeterol xinafoate (SX) from interactive mixtures. SX dispersion was measured by using the fine particle fractions determined by a twin stage impinger attached to a Rotahaler. The particle size of the lactose carrier in the SX interactive mixtures was varied using a range of commercial inhalation-grade lactoses. In addition, differing size fractions of individual lactose samples were achieved by dry sieving. The dispersion of SX appeared to increase as the particle size of the lactose carrier decreased for the mixtures prepared from different particle size commercial samples of lactose and from different sieve fractions of the same lactose. Fine particles of lactose (<5 microm) associated with the lactose carrier were removed from the carrier surface by a wet decantation process to produce lactose samples with low but similar concentrations of fine lactose particles. The fine particle fractions of SX in mixtures prepared with the decanted lactose decreased significantly (analysis of variance, p < 0.001) and the degree of dispersion became independent of the volume mean diameter of the carriers (analysis of variance, p < 0.05). The dispersion behavior is therefore associated with the presence of fine adhered particles associated with the carriers and the inherent size of the carrier itself has little influence on dispersion.
Collapse
Affiliation(s)
- Nazrul Islam
- Department of Pharmaceutics, Victorian College of Pharmacy, Monash University, 381 Royal Parade, Parkville Vic 3052, Australia
| | | | | | | |
Collapse
|