Cryptococcal meningitis management in Tanzania with strict schedule of serial lumber punctures using intravenous tubing sets: an operational research study.
J Acquir Immune Defic Syndr 2014;
66:e31-6. [PMID:
24675586 DOI:
10.1097/qai.0000000000000147]
[Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
BACKGROUND
Cryptococcal meningitis (CM) has a mortality rate of ∼70% among HIV-infected adults in low-income countries. Controlling intracranial pressure (ICP) is essential in CM, but it is difficult in low-income countries because manometers and practical ICP management protocols are lacking.
METHODS
As part of a continuous quality improvement project, our Tanzanian hospital initiated a new protocol for ICP management for CM. All adult inpatients with CM are included in a prospective patient registry. At the time of analysis, this registry included data from 2 years before the initiation of this new ICP management protocol and for a 9-month period after. ICP was measured at baseline and at days 3, 7, and 14 by both manometer and intravenous (IV) tubing set. All patients were given IV fluconazole according to Tanzanian treatment guidelines and were followed until 30 days after admission.
RESULTS
Among adult inpatients with CM, 32 of 35 patients (91%) had elevated ICP on admission. Cerebrospinal fluid pressure measurements using the improvised IV tubing set demonstrated excellent agreement (r = 0.96) with manometer measurements. Compared with historical controls, the new ICP management protocol was associated with a significant reduction in 30-day mortality (16/35 [46%] vs. 48/64 [75%] in historical controls; hazard ratio = 2.1 [95% CI: 1.1 to 3.8]; P = 0.018].
CONCLUSIONS
Increased ICP is almost universal among HIV-infected adults admitted with CM in Tanzania. Intensive ICP management with a strict schedule of serial lumbar punctures reduced in-hospital mortality compared with historical controls. ICP measurement with IV tubing sets may be a good alternative in resource-limited health facilities where manometers are not available.
Collapse