Madanat R, Moritz N, Larsson S, Aro HT. RSA Applications in Monitoring of Fracture Healing in Clinical Trials. Scand J Surg 2016; 95:119-27. [PMID: 16821655 DOI: 10.1177/145749690609500207] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Radiostereometric analysis (RSA) was originally developed as a method for performing highly accurate three-dimensional measurements in vivo over time from sequential radiographs. Since its introduction over twenty years ago, the RSA method has proven itself as a powerful tool with numerous orthopaedic applications. RSA has been used extensively in studies of prosthetic fixation and has been shown to be the method of choice for these studies. RSA has, however, also been successfully applied to a limited number of studies examining fracture healing, namely in fractures of the radius, ankle, tibial plateau, trochanter and femoral neck, as well as studies of bone healing following spinal fusion and tibial osteotomies. RSA follow-up of a fracture will provide definitive demonstration of the exact time of union, i.e. the achievement of fracture stability. This information can be invaluable in randomized clinical trials of fracture treatment. Phantom model studies have proven useful for effective preoperative planning and interpretation of RSA results. The RSA method is a highly accurate, precise and safe objective method for studying fracture healing in clinical trials. The RSA method may serve as a scientific tool to accurately evaluate the significance of supporting novel biomaterials for the early stability and the rate of healing in fractures.
Collapse
Affiliation(s)
- R Madanat
- Orthopaedic Research Unit, Department of Orthopaedic Surgery and Traumatology, University of Turku, Turku, Finland
| | | | | | | |
Collapse
|
102
|
Comparison of 2D radiography and a semi-automatic CT-based 3D method for measuring change in dorsal angulation over time in distal radius fractures. Skeletal Radiol 2016; 45:763-9. [PMID: 26922189 DOI: 10.1007/s00256-016-2350-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2015] [Revised: 02/06/2016] [Accepted: 02/09/2016] [Indexed: 02/02/2023]
Abstract
OBJECTIVE The aim of the present study was to compare the reliability and agreement between a computer tomography-based method (CT) and digitalised 2D radiographs (XR) when measuring change in dorsal angulation over time in distal radius fractures. MATERIALS AND METHODS Radiographs from 33 distal radius fractures treated with external fixation were retrospectively analysed. All fractures had been examined using both XR and CT at six times over 6 months postoperatively. The changes in dorsal angulation between the first reference images and the following examinations in every patient were calculated from 133 follow-up measurements by two assessors and repeated at two different time points. The measurements were analysed using Bland-Altman plots, comparing intra- and inter-observer agreement within and between XR and CT. RESULTS The mean differences in intra- and inter-observer measurements for XR, CT, and between XR and CT were close to zero, implying equal validity. The average intra- and inter-observer limits of agreement for XR, CT, and between XR and CT were ± 4.4°, ± 1.9° and ± 6.8° respectively. CONCLUSIONS For scientific purpose, the reliability of XR seems unacceptably low when measuring changes in dorsal angulation in distal radius fractures, whereas the reliability for the semi-automatic CT-based method was higher and is therefore preferable when a more precise method is requested.
Collapse
|
103
|
Smeragliuolo AH, Hill NJ, Disla L, Putrino D. Validation of the Leap Motion Controller using markered motion capture technology. J Biomech 2016; 49:1742-1750. [DOI: 10.1016/j.jbiomech.2016.04.006] [Citation(s) in RCA: 75] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2015] [Revised: 04/01/2016] [Accepted: 04/04/2016] [Indexed: 11/15/2022]
|
104
|
Boettner F, Sculco P, Lipman J, Renner L, Faschingbauer M. A novel method to measure femoral component migration by computed tomography: a cadaver study. Arch Orthop Trauma Surg 2016; 136:857-63. [PMID: 26983723 DOI: 10.1007/s00402-016-2442-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2015] [Indexed: 11/25/2022]
Abstract
INTRODUCTION Radiostereometric analysis (RSA) is the most accurate technique to measure implant migration. However, it requires special equipment, technical expertise and analysis software and has not gained wide acceptance. The current paper analyzes a novel method to measure implant migration utilizing widely available computer tomography (CT). METHODS Three uncemented total hip replacements were performed in three human cadavers and six tantalum beads were inserted into the femoral bone similar to RSA. Six different 28 mm heads (-3, 0, 2.5, 5.0, 7.5 and 10 mm) were added to simulate five reproducible translations (maximum total point migration) of the center of the head. Implant migration was measured in a 3-D analysis software (Geomagic Studio 7). Repeat manual reconstructions of the center of the head were performed by two investigators to determine repeatability and accuracy. RESULTS The accuracy of measurements between the centers of two head sizes was 0.11 mm with a CI 95 % of 0.22 mm. The intra-observer repeatability was 0.13 mm (CI 95 % 0.25 mm). The interrater-reliability was 0.943. CONCLUSION CT based measurement of head displacement in a cadaver model were highly accurate and reproducible.
Collapse
|
105
|
Breen A, Breen A. Accuracy and repeatability of quantitative fluoroscopy for the measurement of sagittal plane translation and finite centre of rotation in the lumbar spine. Med Eng Phys 2016; 38:607-614. [PMID: 27129784 DOI: 10.1016/j.medengphy.2016.03.009] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2015] [Revised: 02/17/2016] [Accepted: 03/19/2016] [Indexed: 11/17/2022]
Abstract
Quantitative fluoroscopy (QF) was developed to measure intervertebral mechanics in vivo and has been found to have high repeatability and accuracy for the measurement of intervertebral rotations. However, sagittal plane translation and finite centre of rotation (FCR) are potential measures of stability but have not yet been fully validated for current QF. This study investigated the repeatability and accuracy of QF for measuring these variables. Repeatability was assessed from L2-S1 in 20 human volunteers. Accuracy was investigated using 10 consecutive measurements from each of two pairs of linked and instrumented dry human vertebrae as reference; one which tilted without translation and one which translated without tilt. The results found intra- and inter-observer repeatability for translation to be 1.1mm or less (SEM) with fair to substantial reliability (ICC 0.533-0.998). Intra-observer repeatability of FCR location for inter-vertebral rotations of 5° and above ranged from 1.5mm to 1.8mm (SEM) with moderate to substantial reliability (ICC 0.626-0.988). Inter-observer repeatability for FCR ranged from 1.2mm to 5.7mm, also with moderate to substantial reliability (ICC 0.621-0.878). Reliability was substantial (ICC>0.81) for 10/16 measures for translation and 5/8 for FCR location. Accuracy for translation was 0.1mm (fixed centre) and 2.2mm (moveable centre), with an FCR error of 0.3mm(x) and 0.4mm(y) (fixed centre). This technology was found to have a high level of accuracy and with a few exceptions, moderate to substantial repeatability for the measurement of translation and FCR from fluoroscopic motion sequences.
Collapse
Affiliation(s)
- Alexander Breen
- Institute for Musculoskeletal Research and Clinical Implementation, Anglo-European College of Chiropractic, 13-15 Parkwood Road, Bournemouth, Dorset BH5 2DF, UK
| | - Alan Breen
- School of Design Engineering and Computing, Bournemouth University, Talbot Campus, Poole, Dorset BH12 5BB, UK.
| |
Collapse
|
106
|
Quantitative analysis of the patellofemoral motion pattern using semi-automatic processing of 4D CT data. Int J Comput Assist Radiol Surg 2016; 11:1731-41. [DOI: 10.1007/s11548-016-1357-8] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2015] [Accepted: 02/02/2016] [Indexed: 01/31/2023]
|
107
|
Posterior dynamic stabilization in the lumbar spine - 24 months results of a prospective clinical and radiological study with an interspinous distraction device. BMC Musculoskelet Disord 2016; 17:90. [PMID: 26891907 PMCID: PMC4757981 DOI: 10.1186/s12891-016-0945-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/02/2015] [Accepted: 02/13/2016] [Indexed: 11/21/2022] Open
Abstract
Background Interspinous distraction devices (IDD) are due to maintain or restore intersegmental range of motion (iROM) in a controlled fashion with the aim of stabilization the affected level dynamically. The following study is the first to present clinical and radiological data with the Wallis® spacer during a follow-up of 24 months. Methods Ten patients underwent posterior dynamic stabilization (PDS) of the lumbar spine with an IDD (Wallis® spacer) and were controlled clinically and radiologically after 3, 6, 12, and 24 months in a prospective study design. Pain intensity, functional disability and life quality were assessed by use of subjective scores. Motion analyses were performed with the help of lateral functional x-rays to determine the iROM of the operated segments and total ROM (tROM) of the lumbar spine. In addition, roentgen stereophotogrammetric analysis (RSA) was used to measure the iROM of the treated levels. Results During the postoperative course pain and disability most clinical scores were significantly improved. After 24 months we observed statistically significant reduction in back pain intensity with a mean value of 6.0 on visual analog scale (VAS) before surgery and of 2.7 at the latest evaluation. The leg pain was also decreased without statistical significance from 4.7 preoperatively to 2.1 at final follow-up. The functional disability according to Oswestry Disability Index (ODI) and Roland-Morris Disability Questionnaire (RM) was decreased both with statistical significance at all examination dates with a mean value in ODI of 40.0 % before operation and of 17.3 % after 2 years and an initial mean value in RM of 55.2 and of 23.5 % after latest follow-up. After 24 months, the results of the health related quality of life score also showed much better values with only two exceptions. The iROM of the treated levels was reduced during each follow-up examination with preserved residual mobility. Directly postoperatively and after 3 and 12 months intersegmental mobility was statistically significantly decreased with an average iROM of 6.62° before operation and of 2.69° few days after surgery, of 3.79° and 3.16° 3 and 12 months later. At 6 (4.37°) and 24 (4.01°) months follow-up iROM was also but not statistically significantly reduced. The mean tROM did not change significantly during all postoperative controls. Conclusions The radiological findings support the thesis of posterior dynamic stabilization by the used implant. The positive clinical findings should be interpreted with caution because of the limited number of patients and the missing control group.
Collapse
|
108
|
Ouweltjes W, Gussekloo S, Spoor C, van Leeuwen J. A new technique using roentgen stereophotogrammetry to measure changes in the spatial conformation of bovine hind claws in response to external loads. Vet J 2016; 208:81-6. [DOI: 10.1016/j.tvjl.2015.07.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2014] [Revised: 07/07/2015] [Accepted: 07/08/2015] [Indexed: 10/23/2022]
|
109
|
Vrancken ACT, Eggermont F, van Tienen TG, Hannink G, Buma P, Janssen D, Verdonschot N. Functional biomechanical performance of a novel anatomically shaped polycarbonate urethane total meniscus replacement. Knee Surg Sports Traumatol Arthrosc 2016; 24:1485-94. [PMID: 25971457 PMCID: PMC4853448 DOI: 10.1007/s00167-015-3632-6] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2014] [Accepted: 04/29/2015] [Indexed: 12/03/2022]
Abstract
PURPOSE To evaluate the functional biomechanical performance of a novel anatomically shaped, polycarbonate urethane total meniscus implant. METHODS Five human cadaveric knees were flexed between 0° and 90° under compressive loads mimicking a squat movement. Anteroposterior (AP) laxity tests were performed in 30° and 90° flexion. Meniscal kinematics and knee laxity were quantified using roentgen stereophotogrammetric analysis. Tibial cartilage contact mechanics were determined in 90° flexion. Measurements were repeated for the native medial meniscus, the implant, after total medial meniscectomy and allograft transplantation. RESULTS The implant and allograft displayed increased posterior and medial displacements compared to the native meniscus, yet no differences were found between the implant and allograft. Meniscal condition did not affect rotational laxity. Compared to the native joint, AP laxity for the implant was increased in 30° flexion, but not in 90°. The implant reduced the mean contact pressure compared to meniscectomy but could not restore contact pressures to native meniscus levels. Compared to the native meniscus, the implant significantly increased the peak pressure, while the contact area was reduced. Contact mechanics of the implant and allograft were never statistically different. CONCLUSIONS Biomechanical performance was similar for the implant and allograft. However, both meniscal replacements could not restore outcomes to native meniscus levels or sufficiently improve outcomes after meniscectomy. This was presumably caused by the mobility allowed by the suture-only horn fixation. The similarity of implant and allograft performance suggests that the novel implant has the biomechanical potential to serve as an alternative to meniscal allograft transplantation.
Collapse
Affiliation(s)
- A. C. T. Vrancken
- />Orthopaedic Research Lab, Radboud Institute for Health Sciences, Radboud University Medical Center, Huispost 547, PO Box 9101, 6500 HB Nijmegen, The Netherlands
| | - F. Eggermont
- />Orthopaedic Research Lab, Radboud Institute for Health Sciences, Radboud University Medical Center, Huispost 547, PO Box 9101, 6500 HB Nijmegen, The Netherlands
| | - T. G. van Tienen
- />Orthopaedic Research Lab, Radboud Institute for Health Sciences, Radboud University Medical Center, Huispost 547, PO Box 9101, 6500 HB Nijmegen, The Netherlands
| | - G. Hannink
- />Orthopaedic Research Lab, Radboud Institute for Health Sciences, Radboud University Medical Center, Huispost 547, PO Box 9101, 6500 HB Nijmegen, The Netherlands
| | - P. Buma
- />Orthopaedic Research Lab, Radboud Institute for Molecular Life Sciences, Radboud University Medical Center, Nijmegen, The Netherlands
| | - D. Janssen
- />Orthopaedic Research Lab, Radboud Institute for Health Sciences, Radboud University Medical Center, Huispost 547, PO Box 9101, 6500 HB Nijmegen, The Netherlands
| | - N. Verdonschot
- />Orthopaedic Research Lab, Radboud Institute for Health Sciences, Radboud University Medical Center, Huispost 547, PO Box 9101, 6500 HB Nijmegen, The Netherlands , />Laboratory for Biomechanical Engineering, University of Twente, Enschede, The Netherlands
| |
Collapse
|
110
|
Ejaz A, Laursen AC, Jakobsen T, Rasmussen S, Nielsen PT, Laursen MB. Absence of a Tourniquet Does Not Affect Fixation of Cemented TKA: A Randomized RSA Study of 70 Patients. J Arthroplasty 2015; 30:2128-32. [PMID: 26162514 DOI: 10.1016/j.arth.2015.05.058] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2015] [Revised: 05/25/2015] [Accepted: 05/29/2015] [Indexed: 02/01/2023] Open
Abstract
We aimed to determine whether not using a tourniquet in cemented TKA would affect migration of the tibial component measured by radiosterometric analysis (RSA). Seventy patients were randomized into a tourniquet group and a non-tourniquet group and using model-based RSA, the migration of the tibial component was analyzed. Primary and secondary outcome measures were maximum total point motion (MTPM) and translations and rotations. Follow-up period was 2 years. The tibial component was well fixated in both groups and no significant difference in migration between the two groups was detected (P=0.632). Mean MTPM (SD) was 0.47 mm (0.16) in the tourniquet group and 0.45 mm (0.21) in the non-tourniquet group. Absence of tourniquet indicates that stable fixation of the tibial component can be achieved in cemented TKA.
Collapse
Affiliation(s)
- Ashir Ejaz
- Department of Orthopaedic Surgery, Aalborg University Hospital, Aalborg, Denmark; Orthopaedic Surgery Research Unit, Aalborg University Hospital, Aalborg, Denmark; Department of Clinical Medicine, Aalborg University, Aalborg, Denmark
| | - Anders C Laursen
- Department of Orthopaedic Surgery, Aalborg University Hospital, Aalborg, Denmark; Orthopaedic Surgery Research Unit, Aalborg University Hospital, Aalborg, Denmark; Department of Clinical Medicine, Aalborg University, Aalborg, Denmark
| | - Thomas Jakobsen
- Department of Orthopaedic Surgery, Aalborg University Hospital, Aalborg, Denmark; Department of Clinical Medicine, Aalborg University, Aalborg, Denmark
| | - Sten Rasmussen
- Department of Orthopaedic Surgery, Aalborg University Hospital, Aalborg, Denmark; Orthopaedic Surgery Research Unit, Aalborg University Hospital, Aalborg, Denmark; Department of Clinical Medicine, Aalborg University, Aalborg, Denmark
| | - Poul Torben Nielsen
- Department of Orthopaedic Surgery, Aalborg University Hospital, Aalborg, Denmark
| | - Mogens B Laursen
- Department of Orthopaedic Surgery, Aalborg University Hospital, Aalborg, Denmark; Orthopaedic Surgery Research Unit, Aalborg University Hospital, Aalborg, Denmark; Department of Clinical Medicine, Aalborg University, Aalborg, Denmark
| |
Collapse
|
111
|
Roentgen stereophotogrammetric analysis: an effective tool to predict implant survival after an all-poly unicompartmental knee arthroplasty-a 10 year follow-up study. Knee Surg Sports Traumatol Arthrosc 2015; 23:3273-80. [PMID: 25026930 DOI: 10.1007/s00167-014-3106-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/22/2014] [Accepted: 05/27/2014] [Indexed: 10/25/2022]
Abstract
PURPOSE The main purpose of the present study was to determine long-term implant fixation of 15 unicompartmental knee arthroplasty (UKAs) with an all-poly tibial component using Roentgen stereophotogrammetric analysis (RSA) at a mean 10-year follow-up. The secondary purpose was to investigate whether the progressive loss of implant's fixation correlates with a reduction in Knee society score (KSS). METHODS Fifteen non-consecutive patients with primary knee osteoarthritis received a UKA with an all-poly tibial component were assessed using KSS scores pre-operatively and post-operatively and RSA on day 2 after surgery, then at 3, 6, and 12 months and yearly thereafter. The mean last follow-up was 10 years. RESULTS An increase in maximum total point motion (MTPM) values from 6 months to 1 year post-operatively was found respect to post-operative reference. Implants' displacement values were always <2 mm during the first 6 months, and then, two different trends were noticed in revised and non-revised implants. MTPM increase between 1 and 2 years of follow-up in non-revised UKAs was always <0.2 mm, whereas it was >0.2 mm in revised UKAs. A linear and negative correlation with statistical significance was found between MTPM and both clinical and functional KSS scores (p < 0.001). CONCLUSION Also in a long-term follow-up evaluation, RSA is an effective tool to predict functional results after an all-poly UKA providing also a relevant predictive value at 1 year follow-up, and this can be very useful for both patients and surgeons. LEVEL OF EVIDENCE Diagnostic studies, Level III.
Collapse
|
112
|
Ooms EM, ten Brinke B, Mathijssen NMC, Blom IF, Deijkers RLM, Kraan GA. Feasibility of model-based Roentgen Stereophotogrammetric Analysis to evaluate early migration of the trapeziometacarpal joint prosthesis. BMC Musculoskelet Disord 2015; 16:295. [PMID: 26466802 PMCID: PMC4607147 DOI: 10.1186/s12891-015-0747-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/11/2014] [Accepted: 10/02/2015] [Indexed: 11/15/2022] Open
Abstract
Background The purpose of this study was to determine the feasibility of Roentgen Stereophotogrammetric Analysis (RSA) in total joint arthroplasty of the trapeziometacarpal (TMC) joint of the thumb. Methods In five cadaveric hands the TMC-joint was replaced by the Surface Replacement Trapeziometacarpal prosthesis (SR™ TMC prosthesis; Avanta, San Diego, CA) and tantalum beads of 0.8 mm were implanted for RSA. RSA radiographs in two directions were made in ten positions to calculate the measurement error. Migration values from zero are indicative for the measurement error. The number of detected markers was recorded. Results The accuracy analysis showed that for the translations the mean measurement error varied between 0.003 mm (SD 0.057) and 0.055 mm (SD 0.133). For the rotations values ranged from 0.034° (SD 1.759) to 0.502° (SD 1.617). Conclusions RSA analysis of the SR™ TMC prosthesis is feasible. The measurement error is good for the translations but high for the rotations. The latter is due to the close position of the markers relative to each other. Level of evidence III.
Collapse
Affiliation(s)
- E M Ooms
- Centre for Orthopaedic Surgery, OCON, Hand and Wrist unit, Hengelo, The Netherlands.
| | - B ten Brinke
- Department of Orthopaedic Surgery, Reinier de Graaf Groep, Delft, The Netherlands.
| | - N M C Mathijssen
- Department of Orthopaedic Surgery, Reinier de Graaf Groep, Delft, The Netherlands.
| | - I F Blom
- Departments of Radiology and Orthopaedic Surgery, Reinier de Graaf Groep, P.O. Box 5011, 2600 GA, Delft, The Netherlands.
| | - R L M Deijkers
- Department of Orthopaedic Surgery, Haga Ziekenhuis, Den Haag, The Netherlands.
| | - G A Kraan
- Department of Orthopaedic Surgery, Reinier de Graaf Groep, Delft, The Netherlands.
| |
Collapse
|
113
|
Plantar-flexion of the ankle joint complex in terminal stance is initiated by subtalar plantar-flexion: A bi-planar fluoroscopy study. Gait Posture 2015; 42:424-9. [PMID: 26238571 DOI: 10.1016/j.gaitpost.2015.07.009] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2015] [Revised: 07/07/2015] [Accepted: 07/14/2015] [Indexed: 02/02/2023]
Abstract
Gross motion of the ankle joint complex (AJC) is a summation of the ankle and subtalar joints. Although AJC kinematics have been widely used to evaluate the function of the AJC, the coordinated movements of the ankle and subtalar joints are not well understood. The purpose of this study was to accurately quantify the individual kinematics of the ankle and subtalar joints in the intact foot during ground walking by using a bi-planar fluoroscopic system. Bi-planar fluoroscopic images of the foot and ankle during walking and standing were acquired from 10 healthy subjects. The three-dimensional movements of the tibia, talus, and calcaneus were calculated with a three-dimensional/two-dimensional registration method. The skeletal kinematics were quantified from 9% to 86% of the full stance phase because of the limited camera speed of the X-ray system. At the beginning of terminal stance, plantar-flexion of the AJC was initiated in the subtalar joint on average at 75% ranging from 62% to 76% of the stance phase, and plantar-flexion of the ankle joint did not start until 86% of the stance phase. The earlier change to plantar-flexion in the AJC than the ankle joint due to the early plantar-flexion in the subtalar joint was observed in 8 of the 10 subjects. This phenomenon could be explained by the absence of direct muscle insertion on the talus. Preceding subtalar plantar-flexion could contribute to efficient and stable ankle plantar-flexion by locking the midtarsal joint, but this explanation needs further investigation.
Collapse
|
114
|
Flivik G, Kristiansson I, Ryd L. Positive effect of removal of subchondral bone plate for cemented acetabular component fixation in total hip arthroplasty: a randomised RSA study with ten-year follow-up. Bone Joint J 2015; 97-B:35-44. [PMID: 25568411 DOI: 10.1302/0301-620x.97b1.34391] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
We hypothesised that the removal of the subchondral bone plate (SCBP) for cemented acetabular component fixation in total hip arthroplasty (THA) offers advantages over retention by improving the cement-bone interface, without jeopardising implant stability. We have previously published two-year follow-up data of a randomised controlled trial (RCT), in which 50 patients with primary osteoarthritis were randomised to either retention or removal of the SCBP. The mean age of the retention group (n = 25, 13 males) was 70.0 years (sd 6.8). The mean age in the removal group (n = 25, 16 males) was 70.3 years (sd 7.9). Now we have followed up the patients at six (retention group, n = 21; removal group, n = 20) and ten years (retention group: n = 17, removal group: n = 18), administering clinical outcome questionnaires and radiostereometric analysis (RSA), and determining the presence of radiolucent lines (RLLs) on conventional radiographs. RSA demonstrated similar translation and rotation patterns up to six years. Between six and ten years, proximal acetabular component migration and changes of inclination were larger in the retention group, although the mean differences did not reach statistical significance. Differences in migration were driven by two patients in the SCBP retention group with extensive migration versus none in the SCBP removal group. The significant difference (p < 0.001) in the development of radiolucent lines in the retention group, previously observed at two years, increased even further during the course of follow-up (p < 0.001). While recognising SCBP removal is a more demanding technique, we conclude that, wherever possible, the SCBP should be removed to improve the cement-bone interface in order to maximise acetabular component stability and longevity.
Collapse
Affiliation(s)
- G Flivik
- Department of Orthopaedics, Skåne University Hospital, Clinical Sciences, Lund University, Lund S-221 85, Sweden
| | - I Kristiansson
- Department of Orthopaedics, Skåne University Hospital, Clinical Sciences, Lund University, Lund S-221 85, Sweden
| | - L Ryd
- Department of Orthopaedics, Skåne University Hospital, Clinical Sciences, Lund University, Lund S-221 85, Sweden
| |
Collapse
|
115
|
The predictive value of radiostereometric analysis for stem survival in total hip arthroplasty. A systematic review. Hip Int 2015; 24:215-22. [PMID: 24474413 DOI: 10.5301/hipint.5000102] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 08/08/2013] [Indexed: 02/04/2023]
Abstract
BACKGROUND The high precision of radiostereometric analysis (RSA) has enabled us to predict long-term implant survival with a small sample of patients followed for a relatively short period of time. The purpose of our systematic review was to validate the predictive value of two-year RSA results on long-term survival of different types of primary total hip arthroplasty stems. METHODS We systematically reviewed literature to determine the maximum total point motion (MTPM), distal migration and rotation of stem designs and correlated these values to survival rates for aseptic loosening of these specific stems in arthroplasty registries. RESULTS We included 32 studies describing migration of 15 different stem designs. The mean MTPM for straight polished cemented stems was 1.35 mm, for other cemented stems 0.83 mm and for other uncemented stems 1.50 mm. No data were available for the uncemented collared stem. Mean distal migration for straight polished cemented stems was 1.24 mm, for other cemented stems 0.26 mm, the uncemented collared stem 0.40 mm and for other uncemented stems 0.66 mm. Internal rotation was presented for 13 stems and all stems rotated into retroversion. All stems showed 10-year survival rates of >97% corrected for aseptic loosening. DISCUSSION Reporting RSA results in a universal way including interpretation of outliers could improve the predictive value of RSA, allowing this technique to be an important tool during the phased introduction of new implant designs. However, a quality assessment of the data by an experienced reviewer is essential.
Collapse
|
116
|
Similar early migration when comparing CR and PS in Triathlon™ TKA: A prospective randomised RSA trial. Knee 2014; 21:949-54. [PMID: 24974301 DOI: 10.1016/j.knee.2014.05.012] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/07/2013] [Revised: 05/24/2014] [Accepted: 05/28/2014] [Indexed: 02/02/2023]
Abstract
OBJECTIVES The objective of this study was to compare the early migration of the cruciate retaining and posterior stabilising versions of the recently introduced Triathlon™ total knee system, with a view to predicting long term fixation performance. METHODS Sixty patients were prospectively randomised to receive either Triathlon™ posterior stabilised cemented knee prosthesis or Triathlon™ cruciate retaining cemented knee prosthesis. Tibial component migration was measured by radiostereometric analysis postoperatively and at three months, one year and two years. Clinical outcome was measured by the American Knee Society Score and Knee Osteoarthritis and Injury Outcome Score. RESULTS There were no differences in rotation around the three coordinal axes or in the maximum total point motion (MTPM) during the two year follow-up. The posterior stabilised prosthesis had more posterior-anterior translation at three months and one year and more caudal-cranial translation at one year and two years. There were no differences in functional outcome between the groups. CONCLUSION The tibial tray of the Triathlon™ cemented knee prosthesis showed similar early stability. LEVEL OF EVIDENCE Level I. ARTICLE SUMMARY Article focus: This was a prospective randomised trial aiming to compare the single radius posterior stabilised (PS) Triathlon™ total knee arthroplasty (TKA) to the cruciate retaining Triathlon™ TKA system with regard to fixation. Strengths and limitations of this study: Strength of this study was that it is a randomised prospective trial using an objective measuring tool. The sample size of 25-30 patients was reportedly sufficient for the screening of implants using RSA [1]. TRIAL REGISTRATION ClinicalTrials.gov Identifier: NCT00436982.
Collapse
|
117
|
Reiner T, Jaeger S, Schwarze M, Klotz MC, Beckmann NA, Bitsch RG. The stability of the femoral component in the Oxford unicompartmental knee replacement: a comparison of single and twin peg designs. Bone Joint J 2014; 96-B:896-901. [PMID: 24986942 DOI: 10.1302/0301-620x.96b7.33478] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
Aseptic loosening of the femoral component is an important indication for revision surgery in unicompartmental knee replacement (UKR). A new design of femoral component with an additional peg was introduced for the cemented Oxford UKR to increase its stability. The purpose of this study was to compare the primary stability of the two designs of component. Medial Oxford UKR was performed in 12 pairs of human cadaver knees. In each pair, one knee received the single peg and one received the twin peg design. Three dimensional micromotion and subsidence of the component in relation to the bone was measured under cyclical loading at flexion of 40° and 70° using an optical measuring system. Wilcoxon matched pairs signed-rank test was performed to detect differences between the two groups. There was no significant difference in the relative micromotion (p = 0.791 and 0.380, respectively) and subsidence (p = 0.301 and 0.176, respectively) of the component between the two groups at both angles of flexion. Both designs of component offered good strength of fixation in this cadaver study.
Collapse
Affiliation(s)
- T Reiner
- Heidelberg University Hospital, Department of Orthopedics and Traumatology, Schlierbacher Landstraße 200a, Heidelberg, 69118, Germany
| | - S Jaeger
- Clinic for Orthopedics and Trauma Surgery, Laboratory of Biomechanics and Implant Research, Schlierbacher Landstraße 200a, Heidelberg, 69118, Germany
| | - M Schwarze
- Heidelberg University Hospital, Department of Orthopedics and Traumatology, Schlierbacher Landstraße 200a, Heidelberg, 69118, Germany
| | - M C Klotz
- Heidelberg University Hospital, Department of Orthopedics and Traumatology, Schlierbacher Landstraße 200a, Heidelberg, 69118, Germany
| | - N A Beckmann
- Heidelberg University Hospital, Department of Orthopedics and Traumatology, Schlierbacher Landstraße 200a, Heidelberg, 69118, Germany
| | - R G Bitsch
- Heidelberg University Hospital, Department of Orthopedics and Traumatology, Schlierbacher Landstraße 200a, Heidelberg, 69118, Germany
| |
Collapse
|
118
|
Towards understanding knee joint laxity: Errors in non-invasive assessment of joint rotation can be corrected. Med Eng Phys 2014; 36:889-95. [DOI: 10.1016/j.medengphy.2014.03.017] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2013] [Revised: 03/06/2014] [Accepted: 03/24/2014] [Indexed: 12/20/2022]
|
119
|
von Schewelov T, Carlsson A, Sanzén L, Besjakov J. Continuous distal migration and internal rotation of the C-stem prosthesis without any adverse clinical effects: an RSA study of 33 primary total hip arthroplasties followed for up to ten years. Bone Joint J 2014; 96-B:604-8. [PMID: 24788493 DOI: 10.1302/0301-620x.96b5.33580] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
In 2005, we demonstrated that the polished triple-tapered C-stem at two years had migrated distally and rotated internally. From that series, 33 patients have now been followed radiologically, clinically and by radiostereometric analysis (RSA) for up to ten years. The distal migration within the cement mantle had continued and reached a mean of 2 mm (0.5 to 4.0) at ten years. Internal rotation, also within the cement mantle, was a mean 3.8° (external 1.6° to internal 6.6°) The cement mantle did not show any sign of migration or loosening in relation to the femoral bone. There were no clinical or radiological signs indicating that the migration or rotation within the cement mantle had had any adverse effects for the patients.
Collapse
Affiliation(s)
- T von Schewelov
- Skane University Hospital, Department of Orthopaedics, S-205 02 Malmö, Sweden
| | | | | | | |
Collapse
|
120
|
Molt M, Harsten A, Toksvig-Larsen S. The effect of tourniquet use on fixation quality in cemented total knee arthroplasty a prospective randomized clinical controlled RSA trial. Knee 2014; 21:396-401. [PMID: 24238650 DOI: 10.1016/j.knee.2013.10.008] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/30/2013] [Revised: 08/27/2013] [Accepted: 10/17/2013] [Indexed: 02/02/2023]
Abstract
BACKGROUND A concern that arises with any change in technique is whether it affects the long-term implant stability. The objective of this study was to evaluate the early migration, measured by radiostereometric analysis (RSA), and the functional outcome of the Triathlon™ cemented knee prosthesis, operated on with or without a tourniquet. During the last decades RSA has emerged as a way to assess prosthetic fixation and long time prognosis. The method has been used extensively in both hip and knee arthroplasty. METHOD This was a single centre prospective study including 60 patients randomized into two groups operated on either with or without tourniquet. RSA investigation was done within 2-3 days postoperatively after full weight bearing, and then at 3 months, 1 year and 2 years postoperatively. RESULTS There were no differences between the groups regarding the translation along or rotation around the three coordinal axes, or in maximum total point motion (MTPM). At 2 years the mean MTPM (SD) was 0.71 mm (0.64) for the tourniquet-group and 0.53 mm (0.21) for the non-tourniquet-group. CONCLUSIONS The tibial tray of the Triathlon™ cemented knee prosthesis showed similar early stability whether operated on with or without tourniquet. LEVEL OF EVIDENCE Level I. ARTICLE SUMMARY Article focus: A safety study for total knee replacement operated on with or without perioperative tourniquet regarding the prosthetic fixation. Strengths and limitations: Strength of this study is that it is a randomized prospective trial using an objective measuring tool. The sample size of 25-30 patients is reportedly sufficient for the screening of implants using RSA (1-3). TRIAL REGISTRATION Clinical trials NCT01604382, Ethics Committee approval D-nr: 144/20085.
Collapse
Affiliation(s)
- Mats Molt
- Department of Orthopaedics, Hässleholm-Kristianstad-Ystad, Sweden; Department of Clinical Sciences, Lund University, Lund, Sweden.
| | - Andreas Harsten
- Department of Anaesthesiology, Hässleholm Hospital, Hässleholm, Sweden; Department of Clinical Sciences, Lund University, Lund, Sweden
| | - Sören Toksvig-Larsen
- Department of Orthopaedics, Hässleholm-Kristianstad-Ystad, Sweden; Department of Clinical Sciences, Lund University, Lund, Sweden
| |
Collapse
|
121
|
Digas G, Johansson PE, Kärrholm J. Inducible displacements of the cup and the femoral head during active range of motion: dynamic RSA studies of cemented total hip replacements. J Orthop Res 2013; 31:1686-93. [PMID: 24038514 DOI: 10.1002/jor.22428] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/17/2012] [Accepted: 06/07/2013] [Indexed: 02/04/2023]
Abstract
We evaluated changes in position of the femoral head relative to the cup and of the cup relative to the pelvis in total hip replacement patients during hip motion 2 years postoperatively. Two patient groups with nine patients in each group were studied. Hip motions, translations of the femoral head center, and cup displacements were recorded with dynamic radiostereometric examination (RSA, 2 exposures/s) during abduction in Group 1 and with use of static RSA exposures at increasing flexion of the hip in Group 2. Conventional radiographic examinations were used to evaluate any radiolucent lines around the cups at 2 years. During active abduction the femoral head center moved medially (median 0.04 mm) and the cup tilted anteriorly (median 0.09 mm). Increments in radiolucent lines at 2 years correlated to medial femoral head penetration, posterior tilt, and retroversion of the cup at 20° of abduction. The extension of radiolucent lines at 2 years showed a positive correlation with proximal inducible displacement of the cup and posterior translation of the femoral head center at maximum hip flexion. Our observations may be of value in understanding the pathogenesis of the loosening process and may be used to facilitate the development of prosthetic designs that optimize hip kinematics.
Collapse
Affiliation(s)
- Georgios Digas
- Department of Orthopaedics, General Hospital Xanthi, 67100, Xanthi, Greece
| | | | | |
Collapse
|
122
|
Marker-based or model-based RSA for evaluation of hip resurfacing arthroplasty? A clinical validation and 5-year follow-up. Arch Orthop Trauma Surg 2013; 133:1613-21. [PMID: 24100765 DOI: 10.1007/s00402-013-1850-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/01/2013] [Indexed: 10/26/2022]
Abstract
BACKGROUND The stability of implants is vital to ensure a long-term survival. RSA determines micro-motions of implants as a predictor of early implant failure. RSA can be performed as a marker- or model-based analysis. So far, CAD and RE model-based RSA have not been validated for use in hip resurfacing arthroplasty (HRA). MATERIALS/METHODS A phantom study determined the precision of marker-based and CAD and RE model-based RSA on a HRA implant. In a clinical study, 19 patients were followed with stereoradiographs until 5 years after surgery. Analysis of double-examination migration results determined the clinical precision of marker-based and CAD model-based RSA, and at the 5-year follow-up, results of the total translation (TT) and the total rotation (TR) for marker- and CAD model-based RSA were compared. RESULTS The phantom study showed that comparison of the precision (SDdiff) in marker-based RSA analysis was more precise than model-based RSA analysis in TT (p CAD < 0.001; p RE = 0.04) and TR (p CAD = 0.01; p RE < 0.001). The clinical precision (double examination in 8 patients) comparing the precision SDdiff was better evaluating the TT using the marker-based RSA analysis (p = 0.002), but showed no difference between the marker- and CAD model-based RSA analysis regarding the TR (p = 0.91). Comparing the mean signed values regarding the TT and the TR at the 5-year follow-up in 13 patients, the TT was lower (p = 0.03) and the TR higher (p = 0.04) in the marker-based RSA compared to CAD model-based RSA. INTERPRETATION The precision of marker-based RSA was significantly better than model-based RSA. However, problems with occluded markers lead to exclusion of many patients which was not a problem with model-based RSA. HRA were stable at the 5-year follow-up. The detection limit was 0.2 mm TT and 1° TR for marker-based and 0.5 mm TT and 1° TR for CAD model-based RSA for HRA.
Collapse
|
123
|
Ensini A, Barbadoro P, Leardini A, Catani F, Giannini S. Early migration of the cemented tibial component of unicompartmental knee arthroplasty: a radiostereometry study. Knee Surg Sports Traumatol Arthrosc 2013; 21:2474-9. [PMID: 22660971 DOI: 10.1007/s00167-012-2068-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/25/2011] [Accepted: 05/14/2012] [Indexed: 11/26/2022]
Abstract
PURPOSE Unicompartmental knee arthroplasty has good clinical results but high revision rates. A unicompartmental knee arthroplasty design features an all-polyethylene and conforming tibial component, and we hypothesized that this may put at risk its fixation. Implant-to-bone micromotion was measured together with relevant clinical outcomes. METHODS The migration of the tibial component in twenty patients was measured at 3, 6, 12 and 24 months, using standard radiostereometry, along with the relevant clinical outcomes using the IKS scoring system. RESULTS The eighteen arthroplasties at 24 months were found successful, with very good functional (mean 87.7; SD 15.4) and knee scores (mean 94.8; SD 10.1). The means and the standard deviations of the maximum total point motion (MTPM) for the four follow-ups were, respectively, as small as 0.4 ± 0.1 mm, 0.6 ± 0.2 mm, 0.6 ± 0.3 mm and 0.7 ± 0.3 mm, an average over all patients but one. In this knee, these were 1.6, 2.1, 2.4 and 2.2 mm, therefore not at high risk of aseptic loosening according to the literature. Only one knee was found at this risk, having the MTPM from 12 to 24 months of 0.5 mm, and the component moving and sinking medially, and rising laterally. CONCLUSION At 2-year follow-up, a successful implant-to-bone fixation can be achieved in conforming all-polyethylene cemented tibial component together with excellent clinical outcomes.
Collapse
Affiliation(s)
- Andrea Ensini
- Department of Orthopaedic Surgery, Centro di Ricerca Codivilla-Putti, Istituto Ortopedico Rizzoli, University of Bologna, Via Di Barbiano 1/10, 40136, Bologna, Italy
| | | | | | | | | |
Collapse
|
124
|
Horn J, Gunderson RB, Wensaas A, Steen H. Percutaneous epiphysiodesis in the proximal tibia by a single-portal approach: evaluation by radiostereometric analysis. J Child Orthop 2013; 7:295-300. [PMID: 24432090 PMCID: PMC3799934 DOI: 10.1007/s11832-013-0502-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/22/2013] [Accepted: 05/25/2013] [Indexed: 02/03/2023] Open
Abstract
PURPOSE We modified the method for tibial epiphysiodesis by solely using a lateral approach to the physis. From this small-incision approach, the lateral as well as the medial part of the tibial physis were ablated. The aim of our study was to see if this operative technique might be as effective as a bilateral approach, and reduce the operation time and usage time of the image intensifier. The epiphysiodeses were monitored by radiostereometric analysis (RSA), which is a well-established method for the analysis of micro movements and has been used to monitor percutaneous epiphysiodesis with the bilateral approach. There are no reports in the literature comparing single- with double-portal approaches for percutaneous epiphysiodesis evaluated by RSA. METHODS Twenty children were treated by percutaneous epiphysiodesis for leg length discrepancies ranging from 15 to 70 mm, comprising 14 boys and 6 girls with a mean age of 13 (11-15) years. The timing of epiphysiodesis was determined by using Moseley's straight-line graph and Paley's multiplier method. For the tibial epiphysiodesis, ten patients were operated with a single surgical approach from the lateral side (Group I) and ten patients were operated with a surgical approach from both the medial and the lateral sides (Group II). The percutaneous epiphysiodesis was monitored by RSA, a method which allows analysis of the three-dimensional dynamics of the epiphysis relative to the metaphysics. RSA examinations were performed postoperatively and after 6 weeks, 12 weeks, and 6 months. RESULTS From 0 to 6 weeks after epiphysiodesis, the mean longitudinal growth across the operated physis in the tibia in Group I was 0.26 (0.01-0.6) mm. In Group II, the mean growth for the first 6 weeks after surgery was 0.17 (0.01-0.5) mm. During the time period from 6 weeks to 12 weeks after surgery, there was a mean growth of 0.06 (0.00-0.18) mm in Group I and 0.03 (0.00-0.2) mm in Group II. The mean growth from 0 to 6 weeks after epiphysiodesis for all patients was 0.22 mm, which corresponds to 30 % of the normal growth rate. From 6 to 12 weeks, the mean growth for all patients was 0.046 mm, i.e., 6 % of the normal growth rate. From 12 weeks to 24 weeks, no significant growth across the operated physis was observed in neither Group I nor Group II. The mean surgical time was 26 (21-30) min in Group I and 43 (35-48) min in Group II. This difference was statistically significant (p = 0.006). The mean time for use of the image intensifier during surgery was 202 (191-236) s in Group I and 229 (185-289) s in Group II (p = 0.013). CONCLUSIONS In our study, a single-portal technique from the lateral side for percutaneous epiphysiodesis of the proximal tibia was as effective as the double-portal technique. Actual growth arrest appeared within 12 weeks after surgery. A single-portal technique for epiphysiodesis of the tibia is a safe technique, with less surgical time and less time for image intensification compared to the double-portal technique.
Collapse
Affiliation(s)
- Joachim Horn
- Department of Children’s Orthopaedics and Reconstructive Surgery, Oslo University Hospital, Rikshospitalet, Sognsvannsveien 20, 0027 Oslo, Norway
| | - Ragnhild Beate Gunderson
- Department of Radiology, Oslo University Hospital, Rikshospitalet, Sognsvannsveien 20, 0027 Oslo, Norway
| | - Anders Wensaas
- Department of Children’s Orthopaedics and Reconstructive Surgery, Oslo University Hospital, Rikshospitalet, Sognsvannsveien 20, 0027 Oslo, Norway
| | - Harald Steen
- Department of Children’s Orthopaedics and Reconstructive Surgery, Oslo University Hospital, Rikshospitalet, Sognsvannsveien 20, 0027 Oslo, Norway
| |
Collapse
|
125
|
Lauge-Pedersen H, Hägglund G. Eight plate should not be used for treating leg length discrepancy. J Child Orthop 2013; 7:285-8. [PMID: 24432088 PMCID: PMC3799924 DOI: 10.1007/s11832-013-0506-7] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2013] [Accepted: 06/15/2013] [Indexed: 02/03/2023] Open
Abstract
PURPOSE The Blount staple has been widely used for treating angular deformities and leg length discrepancy (LLD) of the lower limbs. In recent years, the Eight plate has replaced the Blount staple for treating angular deformities in many centres. Although not described in the literature, it has been proposed that the Eight plate could also be used for treating LLD. We studied the effectiveness of the device for this indication. METHODS Ten patients with LLD were included prospectively. Medial and lateral plates were inserted for symmetrical growth reduction and the patients were followed by radiostereometric analysis (RSA) 0, 3, 6, 9, 12, 24, 52 and 80 weeks postoperatively. The error of measurement with this technique is less than 0.05 mm. RESULTS Case 1 continued to grow an average of 0.08 mm per week (6.7 mm longitudinal growth in 1.5 years) postoperatively, while Case 2 showed 0.07 mm longitudinal growth per week (5.6 mm longitudinal growth in 1.5 years). The longitudinal growth, in both children, showed only slight growth retardation throughout the follow-up period. The study was interrupted and no further subjects were included after the results indicated that only minor growth reduction had occurred in both patients. CONCLUSION The Eight plate does not significantly reduce growth when applied both medially and laterally in a symmetrical way at the proximal tibial physis.
Collapse
Affiliation(s)
| | - Gunnar Hägglund
- Department of Orthopaedics, University Hospital, 221 85 Lund, Sweden
| |
Collapse
|
126
|
Lin CC, Lu TW, Shih TF, Tsai TY, Wang TM, Hsu SJ. Intervertebral anticollision constraints improve out-of-plane translation accuracy of a single-plane fluoroscopy-to-CT registration method for measuring spinal motion. Med Phys 2013; 40:031912. [PMID: 23464327 DOI: 10.1118/1.4792309] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE The study aimed to propose a new single-plane fluoroscopy-to-CT registration method integrated with intervertebral anticollision constraints for measuring three-dimensional (3D) intervertebral kinematics of the spine; and to evaluate the performance of the method without anticollision and with three variations of the anticollision constraints via an in vitro experiment. METHODS The proposed fluoroscopy-to-CT registration approach, called the weighted edge-matching with anticollision (WEMAC) method, was based on the integration of geometrical anticollision constraints for adjacent vertebrae and the weighted edge-matching score (WEMS) method that matched the digitally reconstructed radiographs of the CT models of the vertebrae and the measured single-plane fluoroscopy images. Three variations of the anticollision constraints, namely, T-DOF, R-DOF, and A-DOF methods, were proposed. An in vitro experiment using four porcine cervical spines in different postures was performed to evaluate the performance of the WEMS and the WEMAC methods. RESULTS The WEMS method gave high precision and small bias in all components for both vertebral pose and intervertebral pose measurements, except for relatively large errors for the out-of-plane translation component. The WEMAC method successfully reduced the out-of-plane translation errors for intervertebral kinematic measurements while keeping the measurement accuracies for the other five degrees of freedom (DOF) more or less unaltered. The means (standard deviations) of the out-of-plane translational errors were less than -0.5 (0.6) and -0.3 (0.8) mm for the T-DOF method and the R-DOF method, respectively. CONCLUSIONS The proposed single-plane fluoroscopy-to-CT registration method reduced the out-of-plane translation errors for intervertebral kinematic measurements while keeping the measurement accuracies for the other five DOF more or less unaltered. With the submillimeter and subdegree accuracy, the WEMAC method was considered accurate for measuring 3D intervertebral kinematics during various functional activities for research and clinical applications.
Collapse
Affiliation(s)
- Cheng-Chung Lin
- Institute of Biomedical Engineering, National Taiwan University, Taiwan 10051, Republic of China
| | | | | | | | | | | |
Collapse
|
127
|
Lin CC, Zhang S, Frahm J, Lu TW, Hsu CY, Shih TF. A slice-to-volume registration method based on real-time magnetic resonance imaging for measuring three-dimensional kinematics of the knee. Med Phys 2013; 40:102302. [DOI: 10.1118/1.4820369] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Affiliation(s)
- Cheng-Chung Lin
- Institute of Biomedical Engineering, National Taiwan University, Taiwan 10051, Republic of China
| | | | | | | | | | | |
Collapse
|
128
|
Lin CC, Lu TW, Wang TM, Hsu CY, Shih TF. Comparisons of surface vs. volumetric model-based registration methods using single-plane vs. bi-plane fluoroscopy in measuring spinal kinematics. Med Eng Phys 2013; 36:267-74. [PMID: 24011956 DOI: 10.1016/j.medengphy.2013.08.011] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2013] [Revised: 06/27/2013] [Accepted: 08/14/2013] [Indexed: 10/26/2022]
Abstract
Several 2D-to-3D image registration methods are available for measuring 3D vertebral motion but their performance has not been evaluated under the same experimental protocol. In this study, four major types of fluoroscopy-to-CT registration methods, with different use of surface vs. volumetric models, and single-plane vs. bi-plane fluoroscopy, were evaluated: STS (surface, single-plane), VTS (volumetric, single-plane), STB (surface, bi-plane) and VTB (volumetric, bi-plane). Two similarity measures were used: 'Contour Difference' for STS and STB and 'Weighted Edge-Matching Score' for VTS and VTB. Two cadaveric porcine cervical spines positioned in a box filled with paraffin and embedded with four radiopaque markers were CT scanned to obtain vertebral models and marker coordinates, and imaged at ten static positions using bi-plane fluoroscopy for subsequent registrations using different methods. The registered vertebral poses were compared to the gold standard poses defined by the marker positions determined using CT and Roentgen stereophotogrammetry analysis. The VTB was found to have the highest precision (translation: 0.4mm; rotation: 0.3°), comparable with the VTS in rotations (0.3°), and the STB in translations (0.6mm). The STS had the lowest precision (translation: 4.1mm; rotation: 2.1°).
Collapse
Affiliation(s)
- Cheng-Chung Lin
- Institute of Biomedical Engineering, National Taiwan University, Taiwan, ROC
| | - Tung-Wu Lu
- Institute of Biomedical Engineering, National Taiwan University, Taiwan, ROC; Department of Orthopaedic Surgery, School of Medicine, National Taiwan University, Taiwan, ROC.
| | - Ting-Ming Wang
- Department of Orthopaedic Surgery, National Taiwan University Hospital, Taiwan, ROC
| | - Chao-Yu Hsu
- Department of Medical Imaging, National Taiwan University Hospital and National Taiwan University Hospital Hsin-Chu Branch, Taiwan, ROC; Department of Radiology, College of Medicine, National Taiwan University, Taiwan, ROC
| | - Ting-Fang Shih
- Department of Radiology, College of Medicine, National Taiwan University, Taiwan, ROC; Department of Medical Imaging, National Taiwan University Hospital, Taiwan, ROC
| |
Collapse
|
129
|
Stihsen C, Rath C, Radl R, Saalabian AA, Materna W, Rehak P, Windhager R. Early migration characteristics of a 180° porous-coated cup with 1-mm press fit. Arch Orthop Trauma Surg 2013; 133:707-12. [PMID: 23475053 DOI: 10.1007/s00402-013-1713-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/16/2013] [Indexed: 11/29/2022]
Abstract
INTRODUCTION Evaluation of early cup movement is an important diagnostic tool to predict the likelihood of long-term implant loosening and clinical failure. The investigated cementless cup is clinically proven over 10 years, but there is a paucity of information that accurately describes the migration characteristics of this component. MATERIALS AND METHODS We retrospectively analysed the clinical outcome and migration behaviour of 60 Pinnacle 100 shells after an average 3.8-year follow-up (range 2.1-5.4 years). For migration measurement, EBRA (Einzel-Bild-Röntgen-Analyse) digital software was applied. Clinical assessment was performed using the HHS, the UCLA score and the SF-36 health survey. RESULTS The clinical outcome showed excellent results with a mean HHS of 95.4 (SD 7.1) and mean UCLA of 6.9 (SD 1.3). All implants were radiologically stable within the observation period and none of the cups was at risk for aseptical loosening. EBRA analysis revealed a mean total migration of 1.4 mm (SD 0.9) (95 % CI 1.1-1.6) at 3 years. Eight cups migrated more than 1 mm within the first three postoperative months, thereafter the migration curves flattened down. CONCLUSION Surgeons may expect to find a variable amount of early migration when using the Pinnacle cup. To our knowledge, these are the first results, which show an early "impaction" of a cementless cup, followed by subsequent osseointegration. We believe that an appropriate long-term outcome of the investigated cup is ensured. The data of the present investigation will provide clinicians with useful baseline information with which to compare new cup designs.
Collapse
Affiliation(s)
- Christoph Stihsen
- Department of Orthopaedic Surgery, Medical University of Vienna, Waehringer Guertel 18-20, Vienna, Austria.
| | | | | | | | | | | | | |
Collapse
|
130
|
Sander K, Rosenbaum D, Böhm H, Layher F, Lindner T, Wegener R, Wolf SI, Seehaus F. [Instrumented gait and movement analysis of musculoskeletal diseases]. DER ORTHOPADE 2013; 41:802-19. [PMID: 23052847 DOI: 10.1007/s00132-012-1947-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Instrumented 3-dimensional gait analysis is increasingly being used for the evaluation of movement disorders in orthopedic and neurological musculoskeletal diseases. Due to the high reliability of the measurements the procedures are appropriate for diagnostic purposes as well as for outcome assessment after conservative or surgical interventions. Contrary to conventional clinical assessments gait analysis parameters are able to demonstrate a normal physiological gait pattern that can be achieved with improved kinematic and kinetic parameters. For a suitable application in clinically relevant problems the limitations of the procedures should be taken into account. Due to the high instrumental involvement combined with time and cost expenditure instrumented gait analysis will probably not develop to a clinical routine procedure. Nevertheless, an excellent set of information for answering clinical questions is provided. The present contribution presents selected measurement procedures and technologies and illustrates the wide variety of possibilities with the use of selected clinical examples.
Collapse
Affiliation(s)
- K Sander
- Abt. Biomechanik, Lehrstuhl für Orthopädie des Universitätsklinikums Jena, Waldkrankenhaus Rudolf Elle GmbH, Klosterlausnitzer Str. 81, 07607, Eisenberg, Deutschland.
| | | | | | | | | | | | | | | |
Collapse
|
131
|
Aspenberg P. Special Review: Accelerating fracture repair in humans: a reading of old experiments and recent clinical trials. BONEKEY REPORTS 2013; 2:244. [PMID: 24404375 DOI: 10.1038/bonekey.2012.244] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2012] [Revised: 11/19/2012] [Accepted: 11/20/2012] [Indexed: 01/30/2023]
Abstract
Based on their mode of action and preclinical data, one would expect bisphosphonates to improve the healing of fractures in cancellous bone, and bone morphogenetic proteins (BMPs) to reduce the risk of non-union in severe shaft fractures. Parathyreoid hormone (PTH) can be expected to accelerate fracture healing in general. The clinical data in support of this is meager. Stimulation of cancellous bone healing and strength by bisphosphonates has been inadvertently shown in the context of implant fixation, but not convincingly in fractures per se. The clinical BMP literature is confusing, and the chance of ever demonstrating reduced numbers of non-union are small, due to power issues. Still, acceleration of 'normal' healing may be possible, but largely remains to show. For PTH, the two available clinical trials both show accelerated healing, but none of them is flawless, and there is a need for better studies.
Collapse
Affiliation(s)
- Per Aspenberg
- Department of Clinical and Experimental Medicine, Division of Orthopaedics, Faculty of Medicine, Linköping University , Linköping, Sweden
| |
Collapse
|
132
|
Almquist PO, Ekdahl C, Isberg PE, Fridén T. Knee rotation in healthy individuals related to age and gender. J Orthop Res 2013; 31:23-8. [PMID: 22778072 DOI: 10.1002/jor.22184] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/12/2012] [Accepted: 06/11/2012] [Indexed: 02/04/2023]
Abstract
An external device ("the Rottometer") was especially designed to measure passive knee rotation in vivo. The device had earlier been evaluated with respect to it's validity and reliability. In the present study, we evaluated knee rotation in knee-healthy individuals and studied possible age and gender related differences. Measurements of total internal-external rotation were made at 90°, 60°, and 30° of flexion using 6 and 9 N m torques, as well as the examiner's apprehension of end-feel as displacing forces. The study group constituted of 120 healthy subjects (60 females and 60 males) with no prior or present knee disorders. The sample was divided into four age groups (15-30, 31-45, 46-60, and >60 years). The results showed no differences in knee rotation between the right and left knees or between the different flexion angles. The females showed 10-20% (p < 0.01) larger knee rotation than the males at all the three flexion angles and at all the three applied torques in all age-matched groups. In all age groups in both genders, the internal rotation accounted for 40-44% and the external for 56-60% of the total internal-external knee rotation.
Collapse
Affiliation(s)
- Per O Almquist
- Division of Physiotherapy, Department of Health Sciences, Lund University, Box 157, SE-221 00 Lund, Sweden.
| | | | | | | |
Collapse
|
133
|
Johnsen LG, Brinckmann P, Hellum C, Rossvoll I, Leivseth G. Segmental mobility, disc height and patient-reported outcomes after surgery for degenerative disc disease. Bone Joint J 2013; 95-B:81-9. [DOI: 10.1302/0301-620x.95b1.29829] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
This prospective multicentre study was undertaken to determine segmental movement, disc height and sagittal alignment after total disc replacement (TDR) in the lumbosacral spine and to assess the correlation of biomechanical properties to clinical outcomes. A total of 173 patients with degenerative disc disease and low back pain for more than one year were randomised to receive either TDR or multidisciplinary rehabilitation (MDR). Segmental movement in the sagittal plane and disc height were measured using distortion compensated roentgen analysis (DCRA) comparing radiographs in active flexion and extension. Correlation analysis between the range of movement or disc height and patient-reported outcomes was performed in both groups. After two years, no significant change in movement in the sagittal plane was found in segments with TDR or between the two treatment groups. It remained the same or increased slightly in untreated segments in the TDR group and in this group there was a significant increase in disc height in the operated segments. There was no correlation between segmental movement or disc height and patient-reported outcomes in either group. In this study, insertion of an intervertebral disc prosthesis TDR did not increase movement in the sagittal plane and segmental movement did not correlate with patient-reported outcomes. This suggests that in the lumbar spine the movement preserving properties of TDR are not major determinants of clinical outcomes. Cite this article: Bone Joint J 2013;95-B:81–9.
Collapse
Affiliation(s)
- L. G. Johnsen
- Norwegian University of Science and Technology
(NTNU), Department of Clinical Neuromedicine, 7049
Trondheim, Norway
| | - P. Brinckmann
- Universitätsklinikum Münster, Klinik
und Poliklinik für Technische Orthopädie und Rehabilitation, Robert-Koch-Straße
30, Münster 48149, Germany
| | - C. Hellum
- Oslo University Hospital, Department
of Orthopaedics, Kirkevn 166, 0407
Oslo, Norway
| | - I. Rossvoll
- University Hospital of Trondheim, Orthopaedic
Department, Trondheim 7030, Norway
| | - G. Leivseth
- Norwegian University of Science and Technology
(NTNU), Department of Clinical Neuromedicine, 7049
Trondheim, Norway
| |
Collapse
|
134
|
Jensen CL, Petersen MM, Schrøder HM, Flivik G, Lund B. Revision total knee arthroplasty with the use of trabecular metal cones: a randomized radiostereometric analysis with 2 years of follow-up. J Arthroplasty 2012; 27:1820-1826.e2. [PMID: 22795879 DOI: 10.1016/j.arth.2012.04.036] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/22/2011] [Revised: 02/28/2012] [Accepted: 04/22/2012] [Indexed: 02/01/2023] Open
Abstract
"Trabecular Metal Cone" (TM Cone) (Zimmer, Inc, Warsaw, Ind) for reconstruction of bone loss in the proximal tibia during revision total knee arthroplasty is now optional. Forty patients were randomized to receive revision total knee arthroplasty with or without TM Cone (No TM Cone). The Anderson Orthopaedic Research Institute bone loss classification and NexGen revision system were used. Radiostereometric analysis was performed with 24 months of follow-up. Maximum total point motion: stable migration was seen in the TM Cone group. No statistically significant difference was found. Segment motion analysis at 24 months showed the same net direction of rotation for the groups around the y-, z-axis and around the x-, y-axis for translation. Tibial revision implants with TM Cone result in an early stable situation with less irregular migration pattern than revision without TM Cone.
Collapse
Affiliation(s)
- Claus L Jensen
- Department of Orthopaedic Surgery U, Rigshospitalet, University of Copenhagen, Denmark
| | | | | | | | | |
Collapse
|
135
|
Molt M, Ljung P, Toksvig-Larsen S. Does a new knee design perform as well as the design it replaces? Bone Joint Res 2012; 1:315-23. [PMID: 23610663 PMCID: PMC3626188 DOI: 10.1302/2046-3758.112.2000064] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/27/2012] [Accepted: 10/09/2012] [Indexed: 11/17/2022] Open
Abstract
Objectives The objective of this study was to compare the early migration
characteristics and functional outcome of the Triathlon cemented
knee prosthesis with its predecessor, the Duracon cemented knee
prosthesis (both Stryker). Methods A total 60 patients were prospectively randomised and tibial
component migration was measured by radiostereometric analysis (RSA)
at three months, one year and two years; clinical outcome was measured
by the American Knee Society score and the Knee Osteoarthritis and
Injury Outcome Score. Results There were no statistically significant differences in rotation
or translation around or along the three coordinal axes, or in the
maximum total point motion (MTPM) during the two-year follow-up. Conclusions The Triathlon cemented knee prosthesis has similar early stability
and is likely to perform at least as well as the Duracon cemented
knee prosthesis over the longer term.
Collapse
Affiliation(s)
- M Molt
- Hässleholm Hospital, Orthopaedic Clinic Hässleholm - Kristianstad - Ystad, Box 351, 281 25 Hässleholm, Sweden
| | | | | |
Collapse
|
136
|
A new technique for the radiostereometric analysis of soft tissues. J Biomech 2012; 45:2931-4. [DOI: 10.1016/j.jbiomech.2012.09.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2012] [Revised: 09/03/2012] [Accepted: 09/04/2012] [Indexed: 11/18/2022]
|
137
|
Pijls BG, Valstar ER, Kaptein BL, Nelissen RGHH. Differences in long-term fixation between mobile-bearing and fixed-bearing knee prostheses at ten to 12 years’ follow-up. ACTA ACUST UNITED AC 2012; 94:1366-71. [DOI: 10.1302/0301-620x.94b10.28858] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
This single-blinded randomised controlled trial investigated whether one design of mobile-bearing (MB) total knee replacement (TKR) has any advantage over a fixed-bearing (FB) design on long-term fixation as measured by radiostereometry. The amount of wear underneath the mobile bearing was also evaluated. A series of 42 knees was randomised to MB or FB tibial components with appropriate polyethylene inserts and followed for between ten and 12 years, or until the death of the patient. The polyethylene in the MB group was superior in that it was gamma-irradiated in inert gas and was calcium-stearate free; the polyethylene in the FB group was gamma-irradiated in air and contained calcium stearate. In theory this should be advantageous to the wear rate of the MB group. At final follow-up the overall mean migration was 0.75 mm (sd 0.76) in the MB group and 0.66 mm (sd 0.4) in the FB group, with the FB group demonstrating more posterior tilt and the MB group more internal rotation. In the FB group there was one revision for aseptic loosening, but none in the MB group. There were no significant differences in clinical or radiological scores. For the MB group, the mean linear wear rate on the under-surface was 0.026 mm/year (sd 0.014). This was significantly smaller than the wear rate of 0.11 mm/year (sd 0.06) in the MB between femur and polyethylene (p < 0.001). Nevertheless, even in a best-case setting the mobile bearings of this TKR design had no apparent advantage in terms of fixation over the FB knee prosthesis at ten to 12 years. The wear underneath the mobile bearing was small and is unlikely to be clinically relevant.
Collapse
Affiliation(s)
- B. G. Pijls
- Leiden University Medical Center, Department
of Orthopaedics, P.O. Box 9600, Postzone
J-11-S 2300 RC Leiden, The Netherlands
| | - E. R. Valstar
- Leiden University Medical Center, Department
of Orthopaedics, P.O. Box 9600, Postzone
J-11-S 2300 RC Leiden, The Netherlands
| | - B. L. Kaptein
- Leiden University Medical Center, Department
of Orthopaedics, P.O. Box 9600, Postzone
J-11-S 2300 RC Leiden, The Netherlands
| | - R. G. H. H. Nelissen
- Leiden University Medical Center, Department
of Orthopaedics, P.O. Box 9600, Postzone
J-11-S 2300 RC Leiden, The Netherlands
| |
Collapse
|
138
|
Seslija P, Teeter MG, Yuan X, Naudie DDR, Bourne RB, MacDonald SJ, Peters TM, Holdsworth DW. Measurement of joint kinematics using a conventional clinical single-perspective flat-panel radiography system. Med Phys 2012; 39:6090-103. [DOI: 10.1118/1.4752205] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
139
|
Haugan K, Husby OS, Klaksvik J, Foss OA. The migration pattern of the Charnley femoral stem: a five-year follow-up RSA study in a well-functioning patient group. J Orthop Traumatol 2012; 13:137-43. [PMID: 22576838 PMCID: PMC3427697 DOI: 10.1007/s10195-012-0187-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/01/2011] [Accepted: 03/10/2012] [Indexed: 11/29/2022] Open
Abstract
BACKGROUND Implant stability is considered vital to long-time implant survival in total hip arthroplasty (THA), since loose implants are reported to be a major cause of hip revision. There is an association between early implant micromotion and increased risk of revision. More implant-specific data are needed to establish acceptable levels of early implant movement. MATERIALS AND METHODS Thirty-five patients (36 hips) undergoing Charnley THA were followed with repeated clinical, radiographic, and radiostereometric analysis (RSA) over 5 years. Twenty-three patients attended 5 years postoperatively. RESULTS The patient group was well functioning based on the radiological and clinical evaluations. The stems constantly moved up to 5 years postoperatively, with subsidence, retroversion, and varus tilt, based on the RSA. CONCLUSION Continuous movement of the Charnley stem was observed up to 5 years postoperatively in a well-functioning patient group. The migration data presented herein could be useful when defining acceptable migration limits for certain types of cemented femoral stems.
Collapse
Affiliation(s)
- Kristin Haugan
- Orthopaedic Research Centre, Trondheim University Hospital, 7006, Trondheim, Norway.
| | | | | | | |
Collapse
|
140
|
Sarnäs KV, Aberg M, Svensson H. Mandibular widening in hemifacial microsomia: a roentgen stereometric study of 11 patients with the aid of metallic implants. Am J Orthod Dentofacial Orthop 2012; 141:S88-91. [PMID: 22449604 DOI: 10.1016/j.ajodo.2011.12.014] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2011] [Revised: 12/01/2011] [Accepted: 12/01/2011] [Indexed: 11/26/2022]
Abstract
INTRODUCTION Our objective was to study mandibular widening in untreated subjects with hemifacial microsomia. METHODS From the 3-dimensional files at the Department of Plastic and Reconstructive Surgery, Skane University Hospital in Malmö, Sweden, data of 11 subjects (3 girls, 8 boys) with hemifacial microsomia were retrieved. Their age range was 9 years 2 months to 13 years 2 months at the first examination. The mean observation period was 5 years 2 months. Each subject was studied by roentgen stereophotogrammetry with the aid of metallic implants. RESULTS A significant widening of the mandible was found, with a mean total change of 0.31 mm (range, 0.08-0.79 mm) and a mean annual change of 0.07 mm (range, 0.03-0.12 mm). In 2 subjects, narrowing of the mandible was found: -0.16 and - 0.23 mm. CONCLUSIONS The mandible got wider during adolescence in 9 of our subjects with hemifacial microsomia but to a lesser extent than has been reported in subjects without hemifacial microsomia and from ordinary orthodontic clinics. Sex difference was not addressed. It was suggested that chewing (forces and patterns) was responsible for the mandibular widening in our subjects; this is in line with previous research.
Collapse
Affiliation(s)
- Karl-Victor Sarnäs
- Department of Plastic and Reconstructive Surgery, Skane University Hospital, Malmö, Sweden
| | | | | |
Collapse
|
141
|
Pijls BG, Nieuwenhuijse MJ, Schoones JW, Middeldorp S, Valstar ER, Nelissen RGHH. RSA prediction of high failure rate for the uncoated Interax TKA confirmed by meta-analysis. Acta Orthop 2012; 83:142-7. [PMID: 22530953 PMCID: PMC3339527 DOI: 10.3109/17453674.2012.672092] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE In a previous radiostereometric (RSA) trial the uncoated, uncemented, Interax tibial components showed excessive migration within 2 years compared to HA-coated and cemented tibial components. It was predicted that this type of fixation would have a high failure rate. The purpose of this systematic review and meta-analysis was to investigate whether this RSA prediction was correct. MATERIALS AND METHODS We performed a systematic review and meta-analysis to determine the revision rate for aseptic loosening of the uncoated and cemented Interax tibial components. RESULTS 3 studies were included, involving 349 Interax total knee arthroplasties (TKAs) for the comparison of uncoated and cemented fixation. There were 30 revisions: 27 uncoated and 3 cemented components. There was a 3-times higher revision rate for the uncoated Interax components than that for cemented Interax components (OR = 3; 95% CI: 1.4-7.2). INTERPRETATION This meta-analysis confirms the prediction of a previous RSA trial. The uncoated Interax components showed the highest migration and turned out to have the highest revision rate for aseptic loosening. RSA appears to enable efficient detection of an inferior design as early as 2 years postoperatively in a small group of patients.
Collapse
Affiliation(s)
| | | | | | - Saskia Middeldorp
- Department of Clinical Epidemiology, Leiden University Medical Centre, Leiden,
| | | | | |
Collapse
|
142
|
Markerless Roentgen Stereophotogrammetric Analysis for in vivo implant migration measurement using three dimensional surface models to represent bone. J Biomech 2012; 45:1540-5. [PMID: 22465625 DOI: 10.1016/j.jbiomech.2012.03.004] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2011] [Revised: 01/31/2012] [Accepted: 03/02/2012] [Indexed: 11/23/2022]
Abstract
Recent studies have shown that model-based RSA using implant surface models to detect in vivo migration is as accurate as the classical marker-based RSA method. Use of bone surface models would be a further advancement of the model-based method by decreasing complications arising from marker insertion. The aim of this pilot investigation was to assess the feasibility of a "completely markerless" model-based RSA in detecting migration of an implant using bone surface models instead of bone markers. A total knee arthroplasty (TKA) was performed on a human cadaver knee, which was subsequently investigated by repeated RSA measurements performed by one observer. The cadaver knee was CT scanned prior to implantation of the TKA. Tibia-fibular surface models were created using two different commercially available software packages to investigate the effect of segmentation software on the accuracy of repeated migration measures of zero displacement by one observer. Reverse engineered surface models of the TKA tibial component were created. The analysis of the RSA images was repeated 10 times by one individual observer. For the markerless method, the greatest apparent migration observed about the three anatomical axes investigated was between -2.08 and 1.35 mm (SD ≤ 0.88) for z-axis translation, and -4.57° to 7.86° (SD ≤ 3.17) for R(y)-axis rotation, which were well beyond out of the range of what is typically considered adequate for clinically relevant RSA measurements. Use of tibia-fibular surface models of the bone instead of markers could provide practical advantages in evaluating implant migration. However, we found the accuracy and precision of the markerless approach to be lower than that of marker-based RSA, to a degree which precludes the use of this method for measuring implant migration in its present form.
Collapse
|
143
|
Moewis P, Wolterbeek N, Diederichs G, Valstar E, Heller MO, Taylor WR. The quality of bone surfaces may govern the use of model based fluoroscopy in the determination of joint laxity. Med Eng Phys 2012; 34:1427-32. [PMID: 22342557 DOI: 10.1016/j.medengphy.2012.01.007] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2011] [Revised: 01/10/2012] [Accepted: 01/22/2012] [Indexed: 01/31/2023]
Abstract
The assessment of knee joint laxity is clinically important but its quantification remains elusive. Calibrated, low dosage fluoroscopy, combined with registered surfaces and controlled external loading may offer possible solutions for quantifying relative tibio-femoral motion without soft tissue artefact, even in native joints. The aim of this study was to determine the accuracy of registration using CT and MRI derived 3D bone models, as well as metallic implants, to 2D single-plane fluoroscopic datasets, to assess their suitability for examining knee joint laxity. Four cadaveric knees and one knee implant were positioned using a micromanipulator. After fluoroscopy, the accuracy of registering each surface to the 2D fluoroscopic images was determined by comparison against known translations from the micromanipulator measurements. Dynamic measurements were also performed to assess the relative tibio-femoral error. For CT and MRI derived 3D femur and tibia models during static testing, the in-plane error was 0.4 mm and 0.9 mm, and out-of-plane error 2.6 mm and 9.3 mm respectively. For metallic implants, the in-plane error was 0.2 mm and out-of-plane error 1.5 mm. The relative tibio-femoral error during dynamic measurements was 0.9 mm, 1.2 mm and 0.7 mm in-plane, and 3.9 mm, 10.4 mm and 2.5 mm out-of-plane for CT and MRI based models and metallic implants respectively. The rotational errors ranged from 0.5° to 1.9° for CT, 0.5-4.3° for MRI and 0.1-0.8° for metallic implants. The results of this study indicate that single-plane fluoroscopic analysis can provide accurate information in the investigation of knee joint laxity, but should be limited to static or quasi-static evaluations when assessing native bones, where possible. With this knowledge of registration accuracy, targeted approaches for the determination of tibio-femoral laxity could now determine objective in vivo measures for the identification of ligament reconstruction candidates as well as improve our understanding of the consequences of knee joint instability in TKA.
Collapse
Affiliation(s)
- P Moewis
- Julius Wolff Institut, Charité-Universitätsmedizin Berlin, Germany
| | | | | | | | | | | |
Collapse
|
144
|
Measurement of in vivo tendon function. J Shoulder Elbow Surg 2012; 21:149-57. [PMID: 22244057 DOI: 10.1016/j.jse.2011.10.023] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/01/2011] [Revised: 10/29/2011] [Accepted: 10/31/2011] [Indexed: 02/01/2023]
Abstract
Chronic tendon pathologies (eg, rotator cuff tears, Achilles tendon ruptures) are common, painful, debilitating, and a significant source of medical expense. Treatment strategies for managing tendon pathologies vary widely in invasiveness and cost, with little scientific basis on which to base treatment selection. Conventional techniques for assessing the outcomes of physical therapy or surgical repair typically rely on patient-based assessments of pain and function, physical measures (eg, strength, range of motion, or stability), and qualitative assessments using magnetic resonance imaging or ultrasound. Unfortunately, these conventional techniques provide only an indirect assessment of tendon function. The inability to make a direct quantitative assessment of the tendon's mechanical capabilities may help to explain the relatively high rate of failed tendon repairs and has led to an interest in the development of tools for directly assessing in vivo tendon function. The purpose of this article is to review methods for assessing tendon function (ie, mechanical properties and capabilities) during in vivo activities. This review will describe the general principles behind the experimental techniques and provide examples of previous applications of these techniques. In addition, this review will characterize the advantages and limitations of each technique, along with its potential clinical utility. Future efforts should focus on developing broadly translatable technologies for quantitatively assessing in vivo tendon function. The ability to accurately characterize the in vivo mechanical properties of tendons would improve patient care by allowing for the systematic development and assessment of new techniques for treating tendon pathologies.
Collapse
|
145
|
Syu CB, Lai JY, Chang RY, Shih KS, Chen KJ, Lin SC. Automatic model-based roentgen stereophotogrammetric analysis (RSA) of total knee prostheses. J Biomech 2012; 45:164-71. [PMID: 22093794 DOI: 10.1016/j.jbiomech.2011.09.011] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2011] [Revised: 09/09/2011] [Accepted: 09/13/2011] [Indexed: 10/14/2022]
Abstract
Conventional radiography is insensitive for early and accurate estimation of the mal-alignment and wear of knee prostheses. The two-staged (rough and fine) registration of the model-based RSA technique has recently been developed to in vivo estimate the prosthetic pose (i.e, location and orientation). In the literature, rough registration often uses template match or manual adjustment of the roentgen images. Additionally, possible error induced by the nonorthogonality of taking two roentgen images neither examined nor calibrated prior to fine registration. This study developed two RSA methods for automate the estimation of the prosthetic pose and decrease the nonorthogonality-induced error. The predicted results were validated by both simulative and experimental tests and compared with reported findings in the literature. The outcome revealed that the feature-recognized method automates pose estimation and significantly increases the execution efficiency up to about 50 times in comparison with the literature counterparts. Although the nonorthogonal images resulted in undesirable errors, the outline-optimized method can effectively compensate for the induced errors prior to fine registration. The superiority in automation, efficiency, and accuracy demonstrated the clinical practicability of the two proposed methods especially for the numerous fluoroscopic images of dynamic motion.
Collapse
Affiliation(s)
- Ci-Bin Syu
- Department of Mechanical Engineering, National Central University, Taoyuan, Taiwan
| | | | | | | | | | | |
Collapse
|
146
|
Figved W, Dahl J, Snorrason F, Frihagen F, Röhrl S, Madsen JE, Nordsletten L. Radiostereometric analysis of hemiarthroplasties of the hip--a highly precise method for measurements of cartilage wear. Osteoarthritis Cartilage 2012; 20:36-42. [PMID: 22126919 DOI: 10.1016/j.joca.2011.11.006] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2011] [Revised: 10/29/2011] [Accepted: 11/08/2011] [Indexed: 02/02/2023]
Abstract
OBJECTIVE Cartilage wear is a feature of osteoarthritis and rheumatoid arthritis. Precise measurements of wear have been difficult. Cartilage wear caused by an artificial articulating joint surface is a well-known feature of hemiarthroplasties. The aim of this study was to demonstrate that radiostereometric analysis (RSA) may be used for three-dimensional measurements of cartilage wear in hemiarthroplasties of the hip. METHOD We performed a phantom model study to assess the feasibility of a subsequent clinical trial. We showed that the motion of the prosthetic head relative to the pelvis was not influenced by the orientation of the prosthetic head. Twenty-two patients were randomised to treatment with a cemented or an uncemented hemiarthroplasty for an acute femoral neck fracture. Migration of the prosthetic head into the acetabulum was measured using RSA. RESULTS A mean migration of the prosthetic head into the acetabulum of 0.62 mm was found at 3 months [95% confidence interval (CI): 0.27-0.97] and a further migration of -0.07 mm at 12 months (95% CI: -0.16-0.32). There were no differences between the groups in prosthetic migration or functional outcome. Between three and 12 months, there was no detectable cartilage wear during the first postoperative year. CONCLUSION Whether the migration during the first 3 months represents a period of bedding in due to a harder opposite surface remains to be shown. RSA may be used for measurement of cartilage wear in hemiarthroplasties of the hip. This study demonstrates a highly precise method for measurements of cartilage wear.
Collapse
Affiliation(s)
- W Figved
- Orthopaedic Department, Oslo University Hospital, 0407 Oslo, Norway.
| | | | | | | | | | | | | |
Collapse
|
147
|
Thien TM, Thanner J, Kärrholm J. Fixation and bone remodeling around a low-modulus stem seven-year follow-up of a randomized study with use of radiostereometry and dual-energy x-ray absorptiometer. J Arthroplasty 2012; 27:134-142.e1. [PMID: 21549557 DOI: 10.1016/j.arth.2011.03.029] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/25/2009] [Revised: 12/20/2010] [Accepted: 03/02/2011] [Indexed: 02/01/2023] Open
Abstract
Thirty-eight patients (40 hips) randomly received either an uncemented fully porous-coated composite stem (Epoch; Zimmer, Warsaw, Ind) or an uncemented proximally porous-coated solid stem (Anatomic; Zimmer). Patients were followed up for 7 years using radiostereometry, dual-energy x-ray absorptiometry, conventional radiography, the Harris Hip Score, and a pain questionnaire. Both stem designs achieved excellent outcome for fixation (stem subsidence and stem rotations close to zero) and clinical outcome, without any difference between the 2 groups (P > .12). Median wear rates were low despite use of conventionally gamma-sterilized polyethylene. No stem was radiographically loose on the postoperative radiographs. The low-modulus composite stem had positive effects on early proximal bone remodeling in Gruen regions 1, 2, 6, and 7 (P < .04). However, at 7 years, this bone-sparing effect persisted in only the calcar region (Gruen region 7).
Collapse
Affiliation(s)
- Truike M Thien
- Departments of Orthopaedics, Sahlgrenska University Hospital, University of Gothenburg, Sweden
| | | | | |
Collapse
|
148
|
Almquist PO, Ekdahl C, Isberg PE, Fridén T. Measurements of knee rotation-reliability of an external device in vivo. BMC Musculoskelet Disord 2011; 12:291. [PMID: 22208736 PMCID: PMC3264542 DOI: 10.1186/1471-2474-12-291] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/01/2011] [Accepted: 12/30/2011] [Indexed: 01/04/2023] Open
Abstract
BACKGROUND Knee rotation plays an important part in knee kinematics during weight-bearing activities. An external device for measuring knee rotation (the Rottometer) has previously been evaluated for validity by simultaneous measurements of skeletal movements with Roentgen Stereometric Analysis (RSA). The aim of this study was to investigate the reliability of the device. METHOD The within-day and test-retest reliability as well as intertester reliability of the device in vivo was calculated. Torques of 3, 6 and 9 Nm and the examiner's apprehension of end-feel were used at 90°, 60° and 30° of knee flexion. Intraclass Correlation Coefficient 2,1 (ICC 2,1), 95% confidence interval (CI) of ICC and 95% CI between test trials and examiners were used as statistical tests. RESULT ICC2,1 ranged from 0.50 to 0.94 at all three flexion angles at 6 and 9 Nm as well as end-feel, and from 0.22 to 0.75 at 3 Nm applied torque. CONCLUSION The Rottometer was a reliable measurement instrument concerning knee rotation at the three different flexion angles (90°, 60° and 30°) with 6 and 9 Nm applied torques as well as the examiner's apprehension of end-feel. Three Nm was not a reliable torque. The most reliable measurements were made at 9 Nm applied torque.
Collapse
Affiliation(s)
- Per O Almquist
- Department of Health Sciences, Division of Physiotherapy, Lund University, Box 157, SE-221 00 Lund, Sweden.
| | | | | | | |
Collapse
|
149
|
Wolf O, Mattsson P, Milbrink J, Larsson S, Mallmin H. The effects of different weight-bearing regimes on press-fit cup stability: a randomised study with five years of follow-up using radiostereometry. INTERNATIONAL ORTHOPAEDICS 2011; 36:735-40. [PMID: 22143314 DOI: 10.1007/s00264-011-1413-5] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2011] [Accepted: 11/01/2011] [Indexed: 11/30/2022]
Abstract
PURPOSE There is little evidence to support immediate weight bearing after uncemented total hip arthroplasty (THA). METHODS Thirty-seven patients with unilateral osteoarthritis of the hip received a press-fit cup. Cup stability was assessed with radiostereometry (RSA) over five years. Patients were randomised to immediate full weight bearing, or partial weight bearing for three months. RESULTS At five years, we found no difference in micro-motion as assessed with radiostereometry. Numerically, there was more proximal translation and increased inclination with immediate weight bearing, but these values barely exceeded the precision limit for the method. Pooled data for the two groups revealed translations of 0.1-0.3 mm and rotations of 0.2-0.3° over the five year follow-up period. CONCLUSIONS We found no adverse effects of immediate weight bearing after THA in relation to stability of these press-fit cups. Early mobilisation might have other advantages.
Collapse
Affiliation(s)
- Olof Wolf
- Surgical Sciences, Orthopaedic, Uppsala, Sweden,
| | | | | | | | | |
Collapse
|
150
|
Stihsen C, Radl R, Keshmiri A, Rehak P, Windhager R. Subsidence of a cementless femoral component influenced by body weight and body mass index. INTERNATIONAL ORTHOPAEDICS 2011; 36:941-7. [PMID: 22052477 DOI: 10.1007/s00264-011-1360-1] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/07/2011] [Accepted: 08/29/2011] [Indexed: 11/30/2022]
Abstract
PURPOSE This trial was designed to evaluate the impact of physical characteristics such as body mass index, body weight and height on distal stem migration of a cementless femoral component, as the influence of obesity on the outcome of THA is still debated in literature and conflicting results have been found. METHODS In this retrospective cohort study, migration patterns for 102 implants were analysed using the Einzel-Bild-Roentgen-Analyse (EBRA-FCA, femoral component analysis). In all cases the Vision 2000 stem was implanted and combined with the Duraloc acetabular component (DePuy, Warsaw, Indiana). RESULTS The mean follow-up was 93 months. EBRA-FCA evaluations revealed a mean subsidence of 1.38 mm after two years, 2.06 mm after five and 2.24 mm after seven years. Five stems loosened aseptically. Correlation between increased migration over the whole period and aseptic loosening was highly significant (p < 0.001). Surgical technique had a significant influence on migration and stem stability (p = 0.002) but physical patient characteristics such as body weight over 75 kg and height over 165 cm also significantly influenced stem subsidence towards progressive migration (p = 0.001, p < 0.001). However, a high BMI did not trigger progressive stem migration (p = 0.87). Being of the male gender raised the odds for increased migration (p = 0.03). CONCLUSION Physical characteristics such as body weight and height showed significant influence on migration patterns of this cementless femoral component. The operating surgeon should be aware that body weight above 75 kg and height over 165 cm may trigger increased stem migration and the surgeon should aim to fit these prostheses as tightly as possible. However this study demonstrates that a high BMI does not trigger progressive stem migration. Further investigations are needed to confirm our findings.
Collapse
Affiliation(s)
- Christoph Stihsen
- University Clinic of Orthopaedic Surgery, Medical University of Graz, 8036, Graz, Austria
| | | | | | | | | |